SENTRON powermanager
- the power monitoring software for smart infrastructures
SENTRON powermanager
What's new on V6?
Project migration Extended device library OPC DA & OPC UA Server/Client
Migration from powermanager classic (V3.6) projects o SENTRON 7KN Powercenter 1000 Open Platform Communications is platform
o Recommended for systems with up to 500 o SENTRON 3WA air circuit breaker independent and ensures the seamless flow of
devices information among devices from multiple vendors.
o Guide to migration of powermanager classic:
SIOS ID
Simplified installation
o Auto update of web URLs
o Admin permission pre check
o Post installation error code process
New OS Support
o Windows 11
o Windows Server 2022
Page 2 Unrestricted | © Siemens 2023
SENTRON powermanager
5. Ordering information
1. Introduction
– system packages
6. Ordering information
– license concept
2. Applications and references
7. System requirements
3. Highlights at a glance
8. Up-to-date with SUS/SUR
4. Features 9. Getting started with the software
Page 3 Unrestricted | © Siemens 2023
SENTRON powermanager
Introduction
Page 4 Unrestricted | © Siemens 2023
SENTRON powermanager
It's time for a new dimension
The new PC-based SENTRON powermanager
– the energy management software for Smart Infrastructure
Page 5 Unrestricted | © Siemens 2023
SENTRON powermanager
First Look
For a brief insight into the software
just click here
Page 6 Unrestricted | © Siemens 2023
SENTRON powermanager
Added value at a glance
Efficiency
Safety
and
security
System
availability
Maximum functionality for transparent power distribution
– collection and visualization of energy data from all areas
Page 7 Unrestricted | © Siemens 2023
SENTRON powermanager
Application and references
Page 8 Unrestricted | © Siemens 2023
SENTRON powermanager
One software product, many applications
Buildings Industrial plants Infrastructure
e.g. hotel chains, shopping malls, e.g. large bakeries, automotive e.g. data centers, logistics centers,
research facilities: energy industry, furniture industry: fast hospitals: avoidance of system
monitoring irrespective of location or identification of existing and failures and critical states in the
over several locations via standard avoidance of future load peaks power supply
IT networks, cost-center-specific through trend analyses
billing
Page 9 Unrestricted | © Siemens 2023
SENTRON powermanager
Selected references
Click Click Click
Buildings Industrial plants Infrastructure
Energy monitoring in a project More energy transparency for Energy monitoring in logistics
for sustainable use of energy one of the biggest sawmills centers and as a solution for
Fraunhofer Institute for Integrated Systems in Europe logistics customers
and Device Technology IISB
Ziegler Holzindustrie KG Rexel Germany
Germany, Erlangen
Germany, Plössberg Maisach
Page 10 Unrestricted | © Siemens 2023
SENTRON powermanager
Highlights at a glance
Page 11 Unrestricted | © Siemens 2023
SENTRON powermanager
Highlights at a glance
Complete overview
Maximum safety and security • Collection, analysis and
• Fail-safety visualization
• Investment protection • Ready-made,
• Data security customizable dashboards
• Continuous monitoring
Corporate energy
management
• Extensive basic
Identifying potential
functionalities
• Insight into device data
• Preparation and
• Condition-based maintenance
export of data
• ISO 50001 compliant
Page 12 Unrestricted | © Siemens 2023
SENTRON powermanager
Highlights
Maximum safety and security
• Fail-safety through Condition Monitoring
• Alarm notification (SMS, email) for better event handling
• Investment protection for existing equipment:
• Simple connection of all SENTRON devices and any
Modbus devices (including 3rd party)
• Communication through an IP address:
• Simplified commissioning, running
operation and security settings
• Increased data security
• Prevents crashes when Windows is shut down without
stopping the expansion module or an irregular runtime
stop (Desigo CC system does not interrupt recording
but shuts down safely)
Page 13 Unrestricted | © Siemens 2023
SENTRON powermanager
Highlights
Identifying potential for optimization
• Targeted insight into important characteristic values of the plant
• Electrical parameters (current, voltage …)
• Status information (energy and power values)
• Condition-based maintenance
• Which device must be replaced/repaired when?
Page 14 Unrestricted | © Siemens 2023
SENTRON powermanager
Highlights
Complete overview
• Collects and stores energy data of all communication-
capable devices
• Supports up to 700 devices
• Ready-made, customizable dashboards for analysis
• Evaluation of load peaks and power curves (energy cost savings)
• Continuous monitoring for early detection of critical plant
conditions
• High system availability
• Simple process for adding additional languages
• Powerful user management: management and tracking of
user accesses, rights and actions thanks to the user,
access and view configuration
Page 15 Unrestricted | © Siemens 2023
SENTRON powermanager
Highlights
Corporate energy management
• Extensive basic functionalities
• Preparation and export of data
• Energy monitoring according to ISO 50001
(incl. certificate of conformity)
• Integrated long-term archive
• Storage of the most important measurement values
• Data evaluation over extended periods
• Direct derivation of measures for cost-cutting
• Fast fault localization
• Predefined reports and messages
• Illustration of the company's own indicators
Page 16 Unrestricted | © Siemens 2023
SENTRON powermanager
Extended reporting
and charting
Page 17 Unrestricted | © Siemens 2023
SENTRON powermanager
Extended reporting and charting
Dashboard: CO2 Emission
• Identify and compare CO2 emission for
whole site or each measuring point
• Manual configuration of CO2 emission
calculation based on energy mix factors
• Hourly, Daily, Weekly, Monthly Yearly
overviews
Page 18 Unrestricted | © Siemens 2023
SENTRON powermanager
Extended reporting and charting
Report: Sankey diagram
• Power distribution in the
building visible at a glance
• Integrated automatic report
• Available at any time in
the email inbox
Page 19 Unrestricted | © Siemens 2023
SENTRON powermanager
Extended reporting and charting
Charts: System, Area/Sector Overview Health, Energy & Power
System or area overview: All relevant electrical loads in the
Overview of the entire location entire building at a glance
Page 20 Unrestricted | © Siemens 2023
SENTRON powermanager
Extended reporting and charting
Charts:
System, Area/Sector Overview Health,
Energy & Power
System/area-wide breaker health dashboard:
• Health of the installation always in view
• Avoidance of plant shutdowns and failures
• Maintenance is preventive and plannable
SENTRON powermanager: the energy management software for Smart Infrastructure.
Page 21 Unrestricted | © Siemens 2023
SENTRON powermanager
Extended reporting and charting
Report: Delimitation of third-party quantities On the safe side with 7KM PAC2200 CLP measuring
devices and integrated report for delimitation of third-
party quantities
Ensuring EEG levy privileges
As of January 1, 2022, anyone benefiting from EEG levy privileges with
regard to the import or self-generation of electrical power must delimit
third-party quantities in accordance with calibration law.
This also means that special requirements are placed on the measuring
equipment.
Delimitation of third-party quantities
Third-party supply is when a company provides another natural person
or legal entity with electrical power for final consumption. This includes,
for example, the current consumption in rented premises, construction
site power or a canteen run by an external provider.
Leased devices, such automatic drink vending machines,
printers/photocopiers or hired IT infrastructure are considered
to be third-party loads.
Page 22 Unrestricted | © Siemens 2023
SENTRON powermanager
Customizable user interface
Page 23 Unrestricted | © Siemens 2023
SENTRON powermanager
Customizable user interface
Alarm bar Switchover between
window default
settings
Navigation bar
Switchover between
"engineering" and
"operating" mode
Selection area
Main area
System browser tree
Context area
Tab with related
Operation tab
elements
Page 24 Unrestricted | © Siemens 2023
SENTRON powermanager
Modified operating concept
Page 25 Unrestricted | © Siemens 2023
SENTRON powermanager
Modified operating concept
Clear views avoid operating errors and facilitate use
Separation of views
Application view Operation and Create and Analyze
Configuring the building to be monitoring evaluate data
monitored reports
Management view Configure and Manage
powermanager platform and create views users
configuring views
Page 26 Unrestricted | © Siemens 2023
SENTRON powermanager
Modified operating concept
Clear roles avoid operating errors and facilitate use
Separation of user roles
Operating Real-time Create and
Operator mode monitoring evaluate
reports
Focus on the core elements
in energy management
Engineering Create and Define plant Configure graphics
Configuration mode modify structure e.g. create single-
devices line diagrams
Setting the device properties
Page 27 Unrestricted | © Siemens 2023
SENTRON powermanager
Optimized workflows
Page 28 Unrestricted | © Siemens 2023
SENTRON powermanager
Optimized workflows
1 Only 2 steps: Specify the device type… 2 … and the IP address and you're done.
• Appropriate (and configurable) default settings can be made to
minimize engineering work
• Drag-and-drop operations and filtering and sorting are possible
• Engineering for a fraction of the costs and time with minimum training requirements
• Expansion of Desigo CC with further trades to simplify energy management
Page 29 Unrestricted | © Siemens 2023
SENTRON powermanager
Supported devices
and reports
Page 30 Unrestricted | © Siemens 2023
SENTRON powermanager
Supported devices and reports
Supported devices SENTRON powermanager Supported reports SENTRON powermanager
Power meters Breakers • Absolute energy • Load variance
• PAC1600 • 3VA-ETU5/ETU8 • Cost center • Power peak
• PAC2200 • 3VA27 • Energy analysis • Standard
• PAC2200CLP • 3WA • Load duration • TOP10 energy
• PAC3100 • 3WL • Delimitation of • Total energy
• PAC3120 third-party quantities
• 3WL10
• PAC3200 • Sankey diagram
Powercenters*
• PAC3220 • 7KN Powercenter 1000
• PAC3200T • 5SL6 COM MCB
• PAC4200 • 5SV6 COM AFDD/MCB
• PAC5100 • 5ST3 COM AS/FC
• PAC5200 • 3NA COM LV HRC
BCM Others
• PAC1200 • Average value
• SEM3 • Calculated value
• Converter
• KPI
• Virtual counter
• Third-party devices * New in V6.0
Page 31 Unrestricted | © Siemens 2023
SENTRON powermanager
Optimized standard views
of Siemens devices
Page 32 Unrestricted | © Siemens 2023
SENTRON powermanager
Optimized standard views of Siemens devices
Line chart shows
Standard device "Cumulated active
screen power import in the
current period" by
• Tab cards
default
• Tiles
Additional data
points can be
selected (in
"engineering"
mode)
Line chart shows
The display elements "Active energy
show the following: import tariff 1" by
• Total active power default and the
• Total apparent power comparison with the
previous period,
• Total power factor
e.g. month
Page 33 Unrestricted | © Siemens 2023
SENTRON powermanager
Optimized standard views of Siemens devices (1/7)
• By default, the line chart shows "Voltage", "Current", "Power",
"Power Demand", "Power Factor" and "THD".
• The data points on the "Custom" tab are selectable data
points in the charts and can be activated/deactivated at any time
• The bar chart shows the "Active energy import tariff 1" of the
current period as compared with the previous period;
in addition, other energy values can be selected
• The duration (hour, day, week, month, year) and interval
(15 min., hour, day, week, month) can be selected
• The "Comparison" function can be deactivated
• The most important values are shown in a grid structure
Page 34 Unrestricted | © Siemens 2023
SENTRON powermanager
Optimized standard views of Siemens devices (2/7)
The "Control" tile shows
The "Measurement Value" tile information about the state of the
provides values that can be digital inputs/outputs and is able
selected by the user to reset min/max values,
counters and events
The "Summary" tile shows the most important values of a
PAC measuring device – for each phase and also total
values
Page 35 Unrestricted | © Siemens 2023
SENTRON powermanager
Optimized standard views of Siemens devices (3/7)
• The "Overview" tile contains relevant information about the condition of the circuit breaker (Condition Monitoring)
• The "Health Indicator" and the "Remaining Lifetime " can be used to plan maintenance intervals better
Page 36 Unrestricted | © Siemens 2023
SENTRON powermanager
Optimized standard views of Siemens devices (4/7)
• The "Device Information" tile
provides "Basic Information"
such as
• Device name, type and
description
• "Device Information" such as
• Plant and location
identifiers, order and serial
number, hardware and
software version …
• Also, "Expansion Information"
about the modules in the
module slot of the device
Page 37 Unrestricted | © Siemens 2023
SENTRON powermanager
Optimized standard views of Siemens devices (5/7)
• The "Power Quality" tab
provides basic information on
the "Summary" tile such as
• "Voltage Distortion",
"Current Distortion",
"Frequency" and "Power
Factor"
• A further tile is shown when
the device has an integrated
web server
• In the "Content" of the web
server, detailed information
about the PQ data analysis
and events is shown
Page 38 Unrestricted | © Siemens 2023
SENTRON powermanager
Optimized standard views of Siemens devices (6/7) The „Summary“ tile of the 3WA
contains important status
information about DAS+ mode
and energy flow:
• Maintenance mode DAS+
(dynamic arc flash
sentry). Reducing energy
from arc faults and
protecting
maintenance personnel in
accordance with
maintenance mode DAS+
• Status of the energy flow
direction
Without being in front of the
3WA, the status of the DAS+
mode (active/inactive) and the
energy flow (forward/reverse)
can be monitored
Page 39 Unrestricted | © Siemens 2023
SENTRON powermanager
Optimized standard views of Siemens devices (7/7)
The „Summary“ tile of the
7KN Powercenter 1000 contains:
• All status information of the 24
end devices (paired/unpaired,
connected/disconnected,…)
• Current information such as
status, current and alarms are
visible at a glance in the
overview
• Up to 24 end devices can be
monitored in one overview
Page 40 Unrestricted | © Siemens 2023
SENTRON powermanager
Extended standard report
workflow for operating comfort
Page 41 Unrestricted | © Siemens 2023
SENTRON powermanager
Extended standard report workflow for operating comfort
• Report templates for power and energy analysis
• Intuitive workflow – Copy/Paste; Drag/Drop
• Individually configurable
report repository structure
• Engineering and setting up energy and power
reports in a fraction of the time
• End users can adapt and define reports as
required
• Improved usability
Page 42 Unrestricted | © Siemens 2023
SENTRON powermanager
Standard reports in
a user-defined folder structure
Page 43 Unrestricted | © Siemens 2023
SENTRON powermanager
Standard reports in a user-defined folder structure
The standard report templates
can be extended to include
• Company logo(s) or
• Defined header and footer
• Without additional licenses
• Users can create a report structure with several folders for easy identification
• Reports are created and stored in multiple formats and are no longer limited to XLS/PDF
• Reports can only be displayed on the computer on which the report is executed – transfer or shared access must be
performed outside the SENTRON powermanager application (unlike SENTRON powermanager V3.5; to be remedied in
an upcoming version)
Page 44 Unrestricted | © Siemens 2023
SENTRON powermanager
Creating dashboards
made easy
Page 45 Unrestricted | © Siemens 2023
SENTRON powermanager
Creating dashboards made easy
Graphics library with hundreds of
predefined elements
• Meaningful graphics can be put together
from various graphical elements – even as
animated elements for states or signals
• Moreover, graphics can be added (adapted)
using the "Graphics Editor" option
• These graphics, created with the "Graphics
Editor", run on the system without an
additional license; they can even be used
on another powermanager system, on
which the "Graphics Editor" option is not
installed
Page 46 Unrestricted | © Siemens 2023
SENTRON powermanager
Creating dashboards made easy
Location overview, single-line or communication topology
Create simple to complex animated graphics in next to no time.
Ready-made device templates provide the key information at a glance and can be easily adapted.
The optional graphics editor allows you to design your workflows easily and entirely according to your needs.
Page 47 Unrestricted | © Siemens 2023
SENTRON powermanager
Simple standard process
for integrating further
devices
Page 48 Unrestricted | © Siemens 2023
SENTRON powermanager
Simple standard process for integrating further devices
Define the device type, incl. hardware and
1
communication capabilities
3
2 Define the display of
data points such as
Selection of data display element,
points, definition of bar/line chart
type and unit and
assignment of a
Modbus register
• The new, independent tool, with which users can specify all details, configurations and properties of devices of other
manufacturers, produces a JSON file.
• The JSON file is then imported into the SENTRON powermanager and the new device type is created in the system.
• As soon as the device type is created in the system, any number of devices can be created in exactly the same way as
regular or standard devices.
Page 49 Unrestricted | © Siemens 2023
SENTRON powermanager
Extended communications
Page 50 Unrestricted | © Siemens 2023
OPC DA & OPC UA Server/Client
External
systems Business-Intelligence software Building control system
OPC
Northbound
OPC Southbound
(data points)
SENTRON
powermanager
SENTRON powermanager
(server/client)
Power monitoring software
SENTRON
7KN Power-
center 1000
Field devices
OPC
(Modbus) SENTRON 3WA SENTRON 3VA Third SENTRON 7KM/7KT SENTRON
air circuit-breaker molded-case party devices measuring devices protective devices PLC Device Business-Intelligence Building control
circuit-breaker software system
Page 51 Unrestricted | © Siemens 2023
OPC DA & OPC UA Server/Client
Benefits Building control system Powermanager – OPC Client
• Greater interoperability
OPC is an open standard, so it works with a Business-Intelligence
The powermanager as OPC client requests
wide variety of systems -> easy to integrate software
data from subordinate field devices and
with your existing setup
systems.
• Increased efficiency SENTRON
Real-time data access from your devices powermanager
and systems, giving you complete control
and visibility over your energy usage Powermanager – OPC Server
• Enhanced security The powermanager as OPC server provides
OPC UA is designed to be secure, so you the requested data to higher-level systems via
can be sure that your data is protected at all the OPC interface.
times
Field Systems
(OPC)
Page 52 Unrestricted | © Siemens 2023
SENTRON powermanager
System requirements
Page 53 Unrestricted | © Siemens 2023
SENTRON powermanager
System requirements
Hardware requirements Virtualization platforms
CPU Intel Core i7 ≥ 3,2 GHz Microsoft HyperV 2016 (recommended)
RAM At least 32 GB RAM
VMware VSphere 6.0, 6.5 and 6.7
Hard disk SSD with 256 GB of free storage space
VGA with at least 1600 x 900 pixels and
Display
16-bit color depth
Supported operating systems
Windows 10 Enterprise/Professional (64-bit)
Windows 11 Enterprise/Professional (64-bit)
Windows Server 2012 Server 2012 R2 (64-bit)
Windows Server 2016 Server 2016 (64-bit)
Windows Server 2019 Server 2019 (64-bit)
Windows Server 2022 Server 2022 (64-bit)
Click
Languages/country packages
IEC1 English (UK), English (USA), German, Italian
IEC2 English (UK), English (USA), Spanish, Portuguese
IEC3 English (UK), English (USA), German, Chinese (simplified)
IEC4 English (UK), English (USA), French (France), Polish
IEC5 English (UK), English (USA), German, Turkish
UL1 English (USA), Spanish, Portuguese, French (Canada)
Page 54 Unrestricted | © Siemens 2023
SENTRON powermanager
For introductory videos and
training just click
Click
Page 55 Unrestricted | © Siemens 2023
Thank you for your attention!
© Siemens 2023
Subject to changes and errors. The information given in this document
only contains general descriptions and/or performance features which
may not always specifically reflect those described, or which may
undergo modification in the course of further development of the
products. The requested performance features are binding only when
they are expressly agreed upon in the concluded contract.
All product designations, product names, etc. may contain trademarks
or other rights of Siemens AG, its affiliated companies or third parties.
Their unauthorized use may infringe the rights of the respective owner.
siemens.com/sentron-digital
Page 56 Unrestricted | © Siemens 2023