Frigorífico AEG 599389789
Frigorífico AEG 599389789
REFRIGERATION
REFRIGERATORS
Edition: 06.2007
1 INTRODUCTION ....................................................................................................................................... 3
2 AIR CIRCULATION.................................................................................................................................... 6
3 REFRIGERATION CIRCUIT...................................................................................................................... 7
4 ELECTRIC WIRING................................................................................................................................... 8
5 COMPONENTS ....................................................................................................................................... 10
5.1 Controls on air box........................................................................................................................... 10
5.2 Electronic board............................................................................................................................... 10
5.2.1 Power and display board ERF550 .......................................................................................... 11
5.3 Cooler compartment ........................................................................................................................ 13
5.3.1 Temperature sensor ............................................................................................................... 14
5.3.2 Air box..................................................................................................................................... 14
5.3.2.1 Air box fan .................................................................................................................... 15
5.3.2.2 Cooler door switch ........................................................................................................ 15
5.4 Freezer compartment ...................................................................................................................... 16
5.4.1 Cold module fan...................................................................................................................... 17
5.4.2 Defrosting heater .................................................................................................................... 17
5.4.3 Thermal switches.................................................................................................................... 17
5.5 Compressor compartment ............................................................................................................... 18
5.5.1 Connector box ........................................................................................................................ 18
7 ACCESSIBILITY ...................................................................................................................................... 24
7.1 Freezer compartment ...................................................................................................................... 24
7.1.1 Battery evaporator .................................................................................................................. 24
7.1.1.1 Replacement of the thermal switches........................................................................... 25
7.2 Air box.............................................................................................................................................. 27
7.3 Compressor compartment ............................................................................................................... 28
8 TROUBLESHOOTING............................................................................................................................. 29
8.1 Water leakage inside the freezer compartment ............................................................................... 29
8.2 Failed defrosting: ............................................................................................................................. 29
9 SPECIAL FUNCTIONS............................................................................................................................ 30
9.1 Manual defrosting ............................................................................................................................ 30
This manual describes the 70 cm wide Combi Top PARTIAL NO FROST refrigerators with ERF550 electronic
produced in the Susegana factory called ZS.
These models feature:
- partial No Frost (no frost freezer, static refrigerator)
- free standing
- single-compressor
- electronic control (electronic board ERF550)
- air box fan in the cooler compartment
They are appliances (RI3406WL and RI3406W) with the following PNCs:
The controls of the appliance are inserted into the air box positioned in the cooler compartment.
The power and control board is of ERF550 type.
The appliance is switched on and off by simply connecting and disconnecting the plug.
The appliance features only one compressor and it is not possible to switch off only one of the two compart-
ments.
The temperatures regulation is the following:
• from +8 to +2 °C for the cooler
The temperature of the fridge compartment is displayed through the lighting up of the LEDs of the electronic
PCB.
The appliance has the following functions:
• Forced ventilation cooler compartment
Key:
A. control panel on the air box
B. cooler compartment
C. cold module
D. freezer compartment (freezer No Frost)
Unlike the NO FROST refrigerators, in the PARTIAL NO FROST type the cooler and freezer compartments are
separated physically.
The battery evaporator cools only the freezer compartment, while the tube evaporator cools only the cooler
compartment.
The cold produced by the battery evaporator in the freezer compartment is distributed by the fan C placed
above the cold module.
AIR FLOW
In case of freezer door opening, the cold module fan does not stop.
Key:
1. compressor;
2. anti-condensation coil;
3. condenser;
4. dehydrator filter;
5. capillary;
6. battery evaporator (freezer compartment);
7. tube evaporator (cooler compartment).
8. exchanger.
COMP compressor
FAN fan
ON on
OFF off
CLOSED closed
OPENED opened
a. yellow-green
b. brown
c. blue
d. white
e. black
f. grey
g. red
Key:
A. temperature selection button
B. LED bar display
C. cooler door button
D. ACTION FREEZE symbol
Key:
1. free
2. free
3. free
1. free
2. free
3. free
Key:
A. cooler air temperature sensor
1. cooler door switch
2. air box
The sensor A has the foamed cable inside the cabinet, therefore it is not replaceable (for further information
please see Service Bulletin 599374122).
In case of cooler door opening, the air box fan does not stop.
The detection of the opening of the cooler door is carried out by means of:
• electromechanic switch for cooler door control (located in the controls of the air box)
Key:
1. cold module fan
2. fan bracket
3. fan blade
4. thermal switches
5. defrosting heater
6. battery evaporator cover
7. insulation
8. battery evaporator
9. aluminium foil
In case of freezer door opening, the cold module fan does not stop.
END OF DEFROSTING + 8 °C - 5 °C
SAFETY + 40 °C + 30 °C
Key:
A. connector box
B. freezer compressor
6.1 Normal
In case of first switching on with a freezer compartment temperature higher than 10 °C, the appliance operates
with a test cycle (for the factory) for a maximum time of about 1,5 hours.
In this period do not check the correct functioning of the appliance, since the loads are activated only for internal
check (compressor, fan and defrosting heater).
If the appliance is disconnected from the mains power supply:
• the compressor is off
• the LED bar display is off
When the appliance is connected to mains power supply, the display is switched on and the temperature is
displayed through the lighting up of the corresponding LED.
Regulate the temperature of the cooler compartment pushing the temperature selection button so as to set the
following value:
• +5 °C in the cooler
When the cooler door is closed, then all the LEDs are off.
In NOFROST freezers, the humidity inside the freezer compartment accumulates on the evaporator battery
thanks to the air circulation, thus preventing the formation of frost on food.
During the normal operation time, the electronic board powers the compressor and the cold module fan circuits.
The fan and the compressor are powered in parallel, thus they are activated and deactivated at the same time.
The operation time that corresponds to the interval between the following defrosting lasts about 14 hours with
normal openings of the door (it can last up to 72 hours if the doors are never opened!).
2. If the internal temperature is lower than the sensor cut-in temperature (CUT-IN), when the power is restored,
the compressor functions in thermostatic conditions and after 5 hours the electronic board activates the de-
frosting procedure (after the compressor cut-out)
The electronic board activates, in any case, the defrosting procedure 5 hours after the first switching on and
after a power failure.
6.1 normal
En caso de puesta en marcha con una temperatura superior a 10 ° C, el aparato funciona con un ciclo de prueba (de
fábrica) durante un tiempo máximo de aproximadamente 1,5 horas.
En este período no comprobar el correcto funcionamiento del aparato, ya que las cargas se activan sólo para la
comprobación interna (compresor, ventilador y calentador de descongelación).
Si el aparato está desconectado de la red eléctrica:
• el compresor está apagado
• la pantalla de la barra LED está apagada
Cuando el aparato está conectado a la red eléctrica, la pantalla se enciende y la temperatura se visualiza a través de la
iluminación del correspondiente LED.
Regular la temperatura del compartimiento del enfriador pulsando el botón de selección de temperatura para ajustar el
siguiente valor:
• +5 ° C en el refrigerador
Cuando la puerta del enfriador está cerrada, todos los LEDs están apagados.
En los congeladores NOFROST, la humedad dentro del compartimento congelador se acumula en la batería del
evaporador gracias a la circulación de aire, evitando así la formación de escarcha en los alimentos.
Durante el tiempo de funcionamiento normal, la placa electrónica alimenta los circuitos del ventilador del compresor y del
módulo frío.
El ventilador y el compresor se alimentan en paralelo, por lo que se activan y desactivan al mismo tiempo.
El tiempo de funcionamiento que corresponde al intervalo entre el siguiente descongelamiento dura unas 14 horas con
aperturas normales de la puerta (puede durar hasta 72 horas si las puertas nunca se abren).
6.3 Descongelación
Toda la humedad del compartimiento se acumula en el evaporador, que es la parte más fría del
compartimiento; Periódicamente, aproximadamente cada 14 horas con la apertura normal de la puerta
(hasta 72 horas si las puertas nunca se abren!), Entonces es necesario descongelar el hielo de la batería.
La descongelación comienza después del corte del compresor o si el compresor se enciende después de
2,5 horas como máximo.
El calor generado por el calentador de descongelación no afecta a la temperatura del compartimiento del
congelador ni a la temperatura de los envases de alimentos, porque la energía térmica se consume en el
proceso de descongelación del hielo del evaporador.
Después de 20 minutos, la tarjeta electrónica comprueba el estado del interruptor térmico del final de la
descongelación cada minuto para detectar el corte.
Cuando el interruptor del final de la descongelación se corta, la PCB electrónica detiene el procedimiento
de descongelación y el compresor, así como el ventilador, no funcionan hasta que hayan transcurrido 60
minutos desde el comienzo del ciclo de descongelación.
Si 1 hora después del arranque del descongelamiento, los interruptores térmicos no se cortan, la tarjeta
electrónica apaga el calentador de descongelación en cualquier caso y continúa su funcionamiento.
El PCB electrónico activa el compresor y el ventilador sólo 60 minutos después del inicio del procedimiento
de descongelación
COMP compressor
FAN fan
ON on
OFF off
CLOSED closed
OPENED opened
START COMIENZO
More than 5 h elapsed after power on & Transcurrieron más de 5 horas después de
compressor off or compressor on for more encendido Y el compresor apagado o el
than 2,5 h? compresor encendido durante más de 2,5 h?
no
yes
ANTIHIELO
DEFROSTING
DEFROSTING ANTIHIELO
• The appliance operates with a preset cycle when the compressor is powered for 20 minutes and
remains off for 30 minutes alternatively
When the sensor operates again normally, the above described conditions terminate.
Characteristics of the NTC sensor:
a) remove the top b) remove the 4 screw covers and remove the 4 fix-
ing screws
c) remove the polystyrene insulation from the sides d) view of the internal components (fan, thermal
cautiously switches and defrosting heater)
In case of replacement of the fan, it is necessary to ensure that the fan draws in air.
a) detach the connector 2 (of the thermal switches), b) detach the connector (of the thermal switches),
cut the cable (of the thermal switches) and insulate cut the cable of the thermal switches and insulate it
it with insulating tape with insulating tape
d) the cable of the new thermal switches must pass through the hole in the compartment
e) seal the hole using the cable grommet cover part no. 2340125018 and the sealant part no. 960016954
f) position the thermal switches and connect the connectors again
a) remove the 2 front fixing screws of the air box b) unscrew the 2 rear fixing screws of the air box
1 The defrosting Unplug the appliance, remove If the resistance value does not
heater is inter- the connector of the heater and correspond to the technical
rupted verify with the tester the correct data, replace the heater
resistance value to the connec-
tor clamps
2 One or both Frost the battery, then detach If the resistance value does not
switches of the the power plug of the appliance, correspond to 0 (zero Ohm)
thermal protectors remove the connector of the replace the thermal switches
are open thermal switches and verify with assembly
the tester the correct resistance
value to the connector clamps
Para llevar a cabo el ciclo de ensayo y el mantenimiento se ha introducido un nuevo procedimiento manual
de descongelación, que debe realizarse a temperatura interna fría (para evitar la posible apertura de los
interruptores térmicos del calentador de descongelación.
En este caso, el PCB electrónico realiza el ciclo de descongelación estándar: cuando el ciclo ha llegado al
final, el aparato empieza a funcionar normalmente.