SERVICIO NACIONAL DE ADIESTRAMIENTO EN TRABAJO INDUSTRIAL

STUDENT’S WORK
PLANNING
FINAL PROJECT – WRITTEN WORK

1. GENERAL INFORMATION

Full names: ANGELES BLAS JEISSON ADRIAN ID: 1423153


Branch Zone/CFP: LIMA CALLAL / CFP-Huaura
Career: MECANICO DE MANTENIMIENTO Semester: IV
Course/ Training M. TECHNICAL ENGLISH
Work topic: IDENTIFYING THE AIR CONDITIONER MAINTENANCE AND CARE TIPS

➢ Air conditioning:

➢ Air conditioning is the process that allows creating and maintaining certain

conditions of temperature, relative humidity and air purity in closed environments.

This process is usually applied to maintain a level of personal comfort.

➢ Types of air conditioners:

➢ Split. The split is one of the most common in homes. ...

➢ Multisplit. ...

➢ Through ducts. ...

➢ Laptop. ...

➢ Solar split. ...

➢ From window. ...

➢ Fan coil. ...

➢ Inverter fan coil.

2
FINAL PROJECT – WRITTEN WORK

➢ Advantages:

➢ Maintain a comfortable temperature. ...

➢ They also work as heating. ...

➢ Reduces environmental humidity. ...

➢ It does not mean excessive electricity consumption. ...

➢ You breathe cleaner air. ...

➢ Eliminates heat and noise. ...

➢ Avoid mosquitoes.

➢ Disadvantages:

➢ Respiratory problems. ...

➢ Dehydration. ...

➢ Headache and migraines. ...

➢ Viral infections. ...

➢ Dryness and irritation of the eyes. ...

➢ Muscle contractures. ...

➢ Skin problems.

3
FINAL PROJECT – WRITTEN WORK

2. WORK PLANNING

ACTIVITIES/
N° TIMETABLE/ DATE OF WORK PRESENTATION
SHOWING
GENERAL
1 25/03/24
REPORT
WORK
2 27/03/24
PLANNING
GUIDING
3 29/03/24
QUESTIONS
GUIDE
4 ANSWER 06/04/24
SHEET
PLANNING
5 07/04/24
SHEET
DRAWING OR
6 08/04/24
SCHEME

3. GUIDING QUESTIONS

During the study research, you must obtain answers to the following questions:

Nº QUESTIONS

1 ¿What maintenance does my air conditioning need?

2 ¿How much power does the air conditioner need?

3
¿Air conditioning duration?

4 ¿What maintenance does an air conditioner need?

4
FINAL PROJECT – WRITTEN WORK

GUIDE ANSWER SHEET

1. ¿What maintenance does my air conditioning need?

❖ Cleaning of the evaporators.

❖ Cleaning of the condensers.

❖ Draining, cleaning and treatment of the cooling tower circuit.

❖ Checking the tightness and levels of refrigerant and oil in refrigeration

equipment.

❖ Checking and cleaning, if applicable, of the boiler smoke circuit.

❖ Checking and cleaning, if applicable, of smoke ducts and chimney.

❖ Cleaning the boiler burner.

❖ Inspection of the expansion vessel.

❖ Review of water treatment systems.

❖ Checking refractory material.

❖ Checking sealing tightness between burner and boiler

❖ General inspection of the gas boiler.

❖ General inspection of diesel boilers.

❖ Checking water levels in circuits.

❖ Tightness check of pipe circuits.

❖ Tightness check of interception valves.

❖ Checking the setting of safety elements

❖ Check and clean water filters

❖ Check and clean air filters t m

❖ Review of thermal exchange batteries

❖ Review of humidification and evaporative cooling devices

5
FINAL PROJECT – WRITTEN WORK

❖ Inspection and cleaning of heat recovery devices

❖ Review of water-air terminal units

❖ Review of t 2t air distribution terminal units

❖ Inspection and cleaning of air delivery and return units

❖ Review of autonomous equipment

❖ Inspection of pumps and fans

❖ Review of the domestic hot water preparation system

❖ Review of the state of thermal insulation

❖ eview of the automatic control system

2. ¿How much power does the air conditioner need?

If you do not have all the necessary data or do not need such precision and detail in

the calculations that we will present below, you can use the following general air

conditioning ratios: Air power in homes: 90-130 W/m2. Air power in offices: 180 – 250

W/m2.

6
FINAL PROJECT – WRITTEN WORK

3. ¿Air conditioning duration?

Generally, the useful life of an air conditioner is 15 years old. Although this also

depends on the use and maintenance that has been given to it, and the quality of the

split itself. Likewise, it is important to keep in mind that it is not strange that failures

may arise from the age of 10 or 12.

7
FINAL PROJECT – WRITTEN WORK

4. ¿What maintenance does an air conditioner need?

The services included in air conditioning maintenance are: filter cleaning, inspection

of the air conditioning drain, inspection of the refrigeration circuit, as well as

replacement of refrigerant gas, inspection and cleaning of the outdoor unit.

8
FINAL PROJECT – WRITTEN WORK

PLANNING SHEET

EXECUTION PROCESS
SECURITY / ENVIRONMENT /
OPERATIONS / STEPS /SUB-STEPS
LAWS - STANDARS

The compressor does not start. It doesn't make


any sound. The electrical power does not reach the

compressor or is not sufficient.

solution process: Maintenance safety

1. enable workspace standards:

2. Check if the appliance is plugged in and if the Carry out the work

voltage in the outlet is correct 120 V ± 10% based on planning. ...

(108 V ~ 132 V) Guarantee ideal

3. If the line to which the appliance is connected conditions in space. ...

is overloaded, remove other electrical loads Estimate the time in

from the circuit and check which the task will be

4. Check the wiring completed. ...

5. Check the thermostat Seek communication. ...

6. Check the defrost timer (if applicable). The Have information about

motor must rotate. The contacts must open the machinery. ...

and close actuated by the corresponding cams Use the necessary

when manually turning the rotor equipment, tools, spare

parts and supplies.

9
FINAL PROJECT – WRITTEN WORK

7. Check condition and specifications of the

compressor thermal protector start relay, start

capacitor and run capacitor (if applicable)

INSTRUCTIONS: You should be as explicit as possible. Graphics help convey ideas better.
Don't forget the quality, environment and SHI aspects.

10
FINAL PROJECT – WRITTEN WORK

DRAWING / SCHEMATIC/DIAGRAM

SITUATION 1 SITUATION 2

11
FINAL PROJECT – WRITTEN WORK

RESOURCE LIST

INSTRUCTIONS: Complete the list of resources necessary to carry out the work.

1. MACHINES AND EQUIPMENT:

❖ air-conditioning

❖ idro washing machine

2. TOOLS AND INSTRUMENTS:

❖ Screwdriver.

❖ Microfiber cloth.

❖ Pressure washer.

❖ Clean brush.

❖ Stairs.

❖ Gloves.

❖ Glasses.

4. MATERIALS AND SUPPLIES:

❖ water

❖ flannel

❖ electric brush