Validate Print Help: Bidder Name
Validate Print Help: Bidder Name
6.00 M&L for GI Tubes,of size 40 mm dia light grade, galvanised, with all fitting , laid in trenches for protection of cable in road 42.00 RM 0.00 INR Zero Only
/drain crossing complete all as specified and directed by Engr -in-Charge.
7.00 M&L for GI Tubes,of size 50 mm dia light grade, galvanised, with all fitting , laid in trenches for protection of cable in road 6.00 RM 0.00 INR Zero Only
/drain crossing complete all as specified and directed by Engr -in-Charge.
8.00 M&L for GI Tubes,of size 80 mm dia light grade, galvanised, with all fitting , laid in trenches for protection of cable in road 6.00 RM 0.00 INR Zero Only
/drain crossing complete all as specified and directed by Engr -in-Charge.
9.00 Supply, laying, testing and commissioning in replacement LT XLPE UG cable insulated, armoured heavy duty electric 1470.00 RM 0.00 INR Zero Only
cable, 1100 volts grade with stranded aluminium conductor of 16 Sqmm 4 core complete including dismantling of old
unserviceable cable complete all as specified and directed by Engr -in-Charge.
10.00 Supply, laying, testing and commissioning in replacement LT XLPE UG cable insulated, armoured heavy duty electric 500.00 RM 0.00 INR Zero Only
cable, 1100 volts grade with stranded aluminium conductor of 35 Sqmm 3.5 core complete including dismantling of old
unserviceable cable complete all as specified and directed by Engr -in-Charge.
11.00 Supply, laying, testing and commissioning in replacement LT XLPE UG cable insulated, armoured heavy duty electric 500.00 RM 0.00 INR Zero Only
cable, 1100 volts grade with stranded aluminium conductor of 50 Sqmm 3.5 core completeincluding dismantling of old
unserviceable cable complete all as specified and directed by Engr -in-Charge.
12.00 Supply, laying, testing and commissioning in replacement LT XLPE UG cable insulated, armoured heavy duty electric 400.00 RM 0.00 INR Zero Only
cable, 1100 volts grade with stranded aluminium conductor of 95 Sqmm 3.5 core complete including dismantling of old
unserviceable cable complete all as specified and directed by Engr -in-Charge.
13.00 Supply, laying, testing and commissioning in replacement LT XLPE UG cable insulated, armoured heavy duty electric 350.00 RM 0.00 INR Zero Only
cable, 1100 volts grade with stranded aluminium conductor of 120 Sqmm 3.5 core complete including dismantling of old
unserviceable cable complete all as specified and directed by Engr -in-Charge.
14.00 Supply, installing, testing and commissioning in replacement of factory made and tested (including CPRI type tested certified panel) LT 1.00 Each Job 0.00 INR Zero Only
Panel board ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZ
AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The panel
shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and 50x50x6mm thick MS angle
iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red
oxide primer, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC
insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and
comprising of the following :-
( Location : Transformer Main Panel near 4 Way RMU )
(a) Incoming :-
(i) MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 36 KA, with thermal and magnetic release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No
(iii) Ammeter digital type with 4 way rotary selector switch-01No
(iv) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three
(v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 800 Amp- set of four
(b) Outgoing :-
(i) MCCB 200 Amp 4 Pole ,50 Hz,415 Volts, 36 KA with thermal magnetic release - 01 Nos.
(ii) MCCB 160 Amp 4 Pole ,50 Hz,415 Volts, 36 KA with thermal magnetic release - 01 Nos.
(iii) MCCB 125 Amp 4 Pole ,50 Hz,415 Volts, 25 KA with thermal magnetic release - 01 Nos.
(iv) MCCB 100 Amp 4 Pole ,50 Hz,415 Volts, 25 KA with thermal magnetic release - 01 Nos
(c) Platform of Panel. :- Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation,
brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC
padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be
such that it is of a height 45 cm above the nearest road level.
Note :-
(i) All out going feeder shall be connected by cable through suitable size gland plate / glands.
(ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
(iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest
Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
15.00 All as per Item No 14 here-in-before but comprising of the following:- (Near Cook House/Ration store bldgNo1) 1.00 Each Job 0.00 INR Zero Only
(a) Incoming :-
(i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with thermal and magnetic release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No
(iii) Ammeter digital type with 4 way rotary selector switch-01No
(iv) CTs ratio 250/5 A ,class 1, ISI marked -01 sets of three
(v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 500 Amp- set of four
(b) Outgoing :-
(i) MCCB 100 Amp 4 Pole ,50 Hz,415 Volts, 36 KA with thermal magnetic release - 03 Nos.
(ii) MCCB 63 Amp 4 Pole ,50 Hz,415 Volts, 36 KA with thermal magnetic release - 03 Nos.
(c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick
in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces
and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts
etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Note:-(i) All out going feeder shall be connected by cable through suitable size gland plate / glands.
(ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
(iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993
(Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard
feature of manufacturer .
16.00 All as per Item No 14 here-in-before but comprising of the following :- (Near Ration Store/Cook House No2) 1.00 Each Job 0.00 INR Zero Only
(a) Incoming :-
(i) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 36 KA, with thermal and magnetic release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No
(iii) Ammeter digital type with 4 way rotary selector switch-01No
(iv) CTs ratio 200/5 A ,class 1, ISI marked -01 sets of three
(v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 400 Amp- set of four
(b) Outgoing :-
(i) MCCB 100 Amp 4 Pole ,50 Hz,415 Volts, 36 KA with thermal magnetic release - 02 Nos.
(ii) MCCB 63 Amp 4 Pole ,50 Hz,415 Volts, 36 KA with thermal magnetic release - 02 Nos.
(iii) MCB TPN 4 Pole, 63 Amp - 04 Nos
(c) Platform of Panel:- Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick
in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces
and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts
etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Note:-(i) All out going feeder shall be connected by cable through suitable size gland plate / glands.
(ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
(iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993
(Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard
feature of manufacturer
17.00 All as per Item No 14 here-in-before but comprising of the following :- ( Near Cook House/Ration Store No3) 1.00 Each Job 0.00 INR Zero Only
(a) Incoming :-
(i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with thermal and magnetic release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No
(iii) Ammeter digital type with 4 way rotary selector switch-01No
(iv) CTs ratio 250/5 A ,class 1, ISI marked -01 sets of three
(v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 500 Amp- set of four
(b) Outgoing :-
(i) MCCB 160 Amp 4 Pole ,50 Hz,415 Volts, 25 KA with thermal magnetic release - 01 Nos.
(ii) MCCB 100 Amp 4 Pole ,50 Hz,415 Volts, 25 KA with thermal magnetic release - 02 Nos.
(iii) MCCB 63 Amp 4 Pole ,50 Hz,415 Volts, 16 KA with thermal magnetic release - 02 Nos.
(iii) MCB TPN 4 Pole, 63 Amp - 02 Nos
(c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick
in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces
and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts
etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Note :-
(i) All out going feeder shall be connected by cable through suitable size gland plate / glands.
(ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
(iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993
(Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard
feature of manufacturer.
18.00 All as per Item No 14 here-in-before but comprising of the following :- 1.00 Each Job 0.00 INR Zero Only
( Near Cook House/Ration store bldg No 4 )
(a) Incoming :-
(i) MCCB 4 pole , 315 Amps,50 Hz,415 Volts, 36 KA, with thermal and magnetic release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No
(iii) Ammeter digital type with 4 way rotary selector switch-01No
(iv) CTs ratio 315/5 A ,class 1, ISI marked -01 sets of three
(v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 630 Amp- set of four
(b) Outgoing :-
(i) MCCB 200 Amp 4 Pole ,50 Hz,415 Volts, 25 KA with thermal magnetic release - 01 Nos.
(ii) MCCB 100 Amp 4 Pole ,50 Hz,415 Volts, 25 KA with thermal magnetic release - 02 Nos.
(iii) MCCB 63 Amp 4 Pole ,50 Hz,415 Volts, 16 KA with thermal magnetic release - 02 Nos.
(iii) MCB TPN 4 Pole, 63 Amp - 02 Nos
(c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick
in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces
and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts
etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Note :-(i) All out going feeder shall be connected by cable through suitable size gland plate / glands.
(ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
(iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993
(Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard
feature of manufacturer.
19.00 Supply and fixing in replacement of outdoor type wall mounted bus bar chamber having 04 pole bus bar of rating 200 10.00 Each Job 0.00 INR Zero Only
Amps fitted with MCCB 100 Amps 4 Pole, 35 KA, 50 HZ as incomer inclding suitable hole in bus bar for outgoing cable
connection including suitable size nut bolt and fastener complete all as specified and directed by the Engg-in-Charge.
20.00 Supply and fixing in replacement of outdoor type wall mounted bus bar chamber having 04 pole bus bar of rating 126 10.00 Each Job 0.00 INR Zero Only
Amps fitted with MCCB 63 Amps 4 Pole, 35 KA, 50 HZ as incomer inclding suitable hole in bus bar for outgoing cable
connection including suitable size nut bolt and fastener complete all as specified and directed by the Engg-in-Charge.
21.00 Supply & installing in replacement of steel tubular swaged poles type 410 SP-31 (9 mtr long) of apprx wt 147 kg 12.00 Each Job 0.00 INR Zero Only
conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate, PCC coping, GI pipe for
cable protection etc. and GI bracket for fitting mounting of flood light fittings, complete all as per manufacturer's
instructions complete all as specified and directed by the Engg-in-Charge.
NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil, PCC
foundation 1:4:8 type D-2, PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of Channel /flat iron incl
nut bolts,clamps etc, 1.5 mtr x 1.5 mtr long for fixing of LED Flood light fitings . The steel pole shall be painted with
bituminious paint in the total lenth inside and up to planting depth outside.
22.00 Supply & fixing in replacement of 90 Watt LED flood light fittings made up of pressure die cast housing with toughned 12.00 Each 0.00 INR Zero Only
glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by the
Engg-in-Charge.
23.00 S&F in replacement KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted 12.00 Each 0.00 INR Zero Only
hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4
strips for 3 phase and neutral 63 Amps and 15 Amps fuse grip with base including embossing/painting of danger notice of
size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of
KIOSK box body complete all as specified and directed.
24.00 Supply, drawing, connecting & testing in replacement of 3 core, 2.5 Sqmm PVC insulated and PVC rounded sheathed, 108.00 RM 0.00 INR Zero Only
copper conductor (flexible) industrial cable 1100 Volts gradde conforming to IS-694 in steel tubular pole from KIOSK box
to light fittings including providing suitable copper lugs complete all as specified and directed by the Engg-in-Charge.
Note : Steel tubular pole shall be measured and paid separetely.
25.00 S&F of time switches astro type in having longitude and latitude of Indian cities in memory 415 V three phase 20 Amp 1.00 Each Job 0.00 INR Zero Only
rating with 20 Amps, 415 Volts, three pole contactor fitted inside factory made 2mm thick steel enclosure duly powder
coated paint complete all as specified and directed by the Engg-in-Charge.
26.00 Supply & fixing of 16 M high mast shaft (in two section) having minium 410 mm bottom, 150 mm top, 4/3 mm section thickness, PCD 490 mm 3.00 Each Job 0.00 INR Zero Only
with base plate of 560x25mm with two wire rop system and accessories. Accessorie include Head frame, Lantern ring with 08 Nos, of lim arms
(symmetrically arrangement), wire ropes, power tool, AOL bracket and 01 set of foundation acccessories, each set consistists of minimum 08
Nos of M30x850mm bolts with anchor plate and 10% templates, suitable for 47 m/sec wind speed including RCC foundation as per drawing
atteched.
Make : Crompton Greaves/ Bajaj Location : Parade Camp Area-01 Parking area (back side) -01
(a) MAST STRUCTURE:- The high Mast shall be of continuously tapered, polygonal cross section polygon type (Minimum 16- Sides) of 15/16
Mtrs. in height presenting good visual appearance and shall be based on proven design to given assured performance, reliability and service.
The Mast shall have an approximate top diameter of say 150 mm to 200 mm and bottom diameter of 410 mm to 450 mm, The weight of the
Mast shall not exceed more than 1600 kgs, excluding weight of Luminaire, to maintain good elasticity of slender structure.
(b) MAST CONSTRUCTION :- The Mast shall be fabricated from special steel plates of BS EN 10025 grade, cut and folded to form polygonal
section and shall be telescopically jointed and fillet welded. The welding shall be in accordance with BS: 5135. The procedural weld geometry
and the workmanship shall be exhaustively tested by the radiography on the completed welded and certificates submitted. The Mast shall be
delivered in only 2 sections without any circumferential welding at site, which shall be joined together by slip-stressed-fit method. The joining
shall be with stressing equipment, thus forming the sleeve joint. No site welding or bolted the joint will be accepted. The overlap distance shall
have full penetration of longitudinal welds. The base plate of the mast shall be at least 25 mm. thick. An adequate door opening min 1400mm
x 300mm shall be provided at base of each mast such as to permit clear access to equipment like winches, cable pug and socket, etc. The
opening shall be complete with a close fitting vandal resistant, weather-proof door provided with a heavy duty lock. For metal protection of the
Mast, the entire fabricated Mast shall be hot dip galvanised internally and externally, having minimum average thickness of 65 microns.
(c) DYNAMIC LOADING:- The Mast structure shall be designed for an assumed maximum reaction arising from the maximum wind speed at
Mendhar and measured at a height of 10 Mtrs. above ground level . The design life of the Mast shall be min. 25 years. Wind excited oscillation
shall be damped by the method of construction and adequate allowance made for the related stresses. The offered High Mast shall be a tested
design.
(d) FOUNDATION:- The tenderer shall see the site closely and minutely with regard to the nature of the soil, average depth of decomposed
garbage and debris at proposed Mast locations and the other site conditions before working out the type of foundation and specifications for
the proposed High Mast. The tenderer shall be responsible for the design of the foundation and safe erection and installation of the High Mast
in mechanically and structurally safe working condition for the design life of the Mast as per manufacture design The load bearing (safe)
capacity of the soil shall be indicted by purchaser to decide the type of foundation and its specifications. The holding down bolts shall be at
least 8 Nos of high tensile strength and shall be supplied complete with anchor plate of 6 mm thick for casting into the foundation. The ensure
correct vertically and horizontality of bolt alignment.
(Note : Cost of foundation as per specification of manufacturer shall be deemed to be included in the rate quoted by the contractor)
26.01 (e) LANTERN CARRIAGE:- The fabricated lantern carriages shall be provided for holding fittings and control gear provided on each High
Mast. The lantern carriage shall be of special design and of durable steel tube construction designed to act as electric conduit with cable
holes fully protected by grummets. The diameter of the lantern carriage shall be suitable so as to hold designed number of LED floodlight
fittings, as specified in the tender design along with the control gear boxes and lantern. The lantern carriage shall be fabricated in three
parts joined by bolted flanges with SS bolts with nuts to enable easy removal from the erected mast for replacement/ maintenance
purpose. The carriage shall be supported/ suspended by three wire ropes for better stability. The lantern carriage Assembly shall not
touch the lower surface of the Mast. The carriage design and fabrication shall be such that the lantern carriage will suit the lanterns and
their control gear boxes to be used in the work. The Lantern Carriage shall be so installed that it does not cause any damage to the
surface of the Mast and is provided with protective buffer arrangement. The complete Lantern carriage shall be hot dip galvanised after
fabrication. The weather - proof cast aluminum junction boxes (IP-66) shall be provided on the Lantern carriage assembly from which the
inter- connections will be made to the designed number of floodlight fittings and lanterns on the carriage.
(f) MECHANICAL ARRANGEMENT:- For installation and maintenance purpose, it will become necessary to raise or lower the lantern
carriage assembly. To enable this, a suitable winch arrangement shall be provided in the base of the Mast, complete with top pulley,
winch stainless steel wire ropes and winch driving power tool.
(i) WINCH:- The winch shall be of completely self-sustaining type. the winches shall be of self- sustaining type by means of an oil bath
and the lubrication shall be of recommended quality. Termination of the ropes of the winch shall be in such a way, that it does not
involve distortion or twisting of the rope configuration. At least 6 turns of rope shall remain in tension on the drum even when the lantern
carriage is fully lowered. the winch shall be designed to be installed or removed form the door opening at the base of the mast. The
winch drums shall be grooved to ensure mechanically strong, stable and tidy rope lay with no chances of rope slippage or skippage. The
winch shall be capable of operation by hand or by means of external power tool. Integrated power tool with worm is not acceptable. A
test certificate shall be supplied along with each winch in support of the maximum load operated by the winch and for the safety of
operation at the full load rotation. A handle shall also be provided for hand operation of the winches.
26.02 (ii) TOP PULLEY ASSEMBLY:- The top pulleys shall be of a diameter, appropriately large enough to accommodate the steel wire ropes
and the multicore electric cable. The material of construction of the pulley blocks shall be non- corrosive and made of dia cast (LM-6)
aluminum alloy. The pulley assembly shall be complete with self lubricating bearing and stainless steel spindle.
(iii) STAINLESS STEEL WIRE ROPES:- Stainless steel wire shall be AISC 316 grade 7/ 19 construction 2 Nos ropes for winch and 3 Nos
for lantern carriage, 6 mm dia having a breaking load capacity of 2350 kg complete with stainless steel thimbles. The end for connection
to the winch drum shall be fitted with thimbles and the thimbles shall be secured by copper compression splices. (g) CABLE AND CABLE
CONNECTIONS :- The connections shall be made with flat core flexible round sheath power cables of appropriate rating as per the
schedule. The base compartment of the High Mast shall have one terminal box for terminating the incomer cable. The maintenance
cables equal to that within the Mast and fitted with travelling cable 5 core 4 sqmm flexible having plug socket shall be provided to
energize lanterns while in lowering position by hooking up at the base compartment socket supply. Similarly, the provision shall be made
for electric supply at the base compartment to enable operation of the external power tool for lowering or rising of the lantern carriage
assembly. The trailing cables of the lantern carriage rings shall be terminated by means of metal cased plug and socket provided in the
base compartment to enable flexibility.
(h) WINCH DRIVING POWER TOOL :- The electric driven tool shall be single speed, (1.2 Mt/min) reversible three phase & hand
operated motor. The power tool shall be complete with very robust remote control switch such that the tool can be operated from safe
distance of 5 Mtrs. There shall be and arrangement for self alignment off power tool which can be self supported during operation.
Manual handle shall be provided for hand operation of the winches. The capacity rating and speed of the electric motor used in the
power tool shall be specified by the tenderers.
(j) LIGHTNING FINIAL & AVIATION OBSTRUCTION LIGHTS:- One number heavy duty hot dip galvanised lighting finial suitable for
fixing 08 Nos flood light of 200 watt capacity shall be provided for each mast. Suitable aviation obstruction lights of reliable design and
reputed manufacturer shall be provided on top of each mast.
27.00 S&F LED Flood light 200W with IP66 Protection including all fixing accessories complete all as specified and directed by 16.00 Each 0.00 INR Zero Only
Engr -in-Charge. Make:- Surya Cat No. SLF FL 200W IP 65 Lumos or equivalent in Philips/GE
28.00 S&F of twin dome aviation obstruction lights including all fixing accessories complete all as specified and directed by Engr - 2.00 Each 0.00 INR Zero Only
in-Charge. Make:- Surya Cat No SLF AL 108 LDR SEN IP 65 or equivelent in Philips/GE
29.00 S&F outdoor stand mounted feeder pillar 32 A TPN MCB incomer,single dial time switch, 25A TP contactor for the automatic 2.00 Each Job 0.00 INR Zero Only
switching of luminaries, power tool control with 2 Nos 9A contractors and raise lower push button, incoming 35 Sqmm and
outgoing 16 & 2.5 Sqmm terminals (type STD4) complete all as specified and directed by Engr -in-Charge.
30.00 S&F 4 mm dia MS wire 150 mm x 100 mm mesh, made upto into mattress or cages appx 1.5 mtr height and fixed with 24.00 Sqm 0.00 INR Zero Only
flate iron/angle by welding in position and directed including complete all as specified and directed by Engr -in-Charge.
Note:- MS angle /MS flate will be measured and paid seperately.
31.00 M&L for applying two coats of synthetic enamel paint of silver colour on steel surfaces over a coat of red oxide primer 49.00 Sqm 0.00 INR Zero Only
including preparation of surfaces complete all as specified and directed by Engr -in-Charge.
32.00 M&L for cement concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) for sub floors, sub-bases, 1.00 cum 0.00 INR Zero Only
floors, foundation and paving etc complete all as specified and directed by Engr -in-Charge.
33.00 M&L for MS work of angles, flat, cross arms, bracings, supports, clamps for post and struts of fencing around transformer 2.50 Qtl 0.00 INR Zero Only
plinth etc drilling holes, flate iron fillet for securing wire mess by welding to angle iron frame and framed work as in door/
gate of angle and wire mess. Door to be fixed by 03 Nos 100mm long hinges and one sliding door bolt of 300mm long for
locking arrangement or similar works complete all as specified and directed by the Engg-in-Charge.
34.00 Demolition of PCC as in path/concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) 1.00 cum 0.00 INR Zero Only
complete all as specified and directed by Engr -in-Charge.
35.00 Boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI 60.00 RM 0.00 INR Zero Only
pipe 50 to 100mm bore and making good both ends all specified and directed by the Engg-in-Charge.
36.00 Earthing complete with galvanised steel earth plate electrode 60cm × 60cm × 6mm thick, buried directly in ground (earth 10.00 Each Set 0.00 INR Zero Only
pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal
ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of
galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated
including testing on completion and complete all as specified and directed by Engr -in-Charge.
37.00 M&L for plate Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground 15.00 Each Set 0.00 INR Zero Only
(earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below
normal ground level connected to galvanized earth strip 25 x 4 mm by means of bolts and nuts checknuts and washers of
galvanized iron electric arc welding all joints all as specified and shown in electrical plate No 3 of SSR part I including
necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick
cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade for protection of earth
electrode 20 mm dia for watering and tested on completion complete all as specified and directed by the Engg-in-Charge.
38.00 Supply, installation, testing & commissioning HIGH MAST LT panel board, outdoor type, suitable for operation on 415 1.00 Each 0.00 INR Zero Only
volts, AC 3 phase, 4 wire, 50 Hz electric supply system,outer body made out of 3.15 mm thick & inner shell made out of
2.00 mm thick CRCA sheet, side covers with front and back hinged doors with proper locking arrangement, rubber gasket
on front and back to make it dust and vermin proof, powder coated , The cubicle shall have frame work, bottom & 45 CM
long four legs of size 50 x 50 x 6 mm Angle iron, aluminium main busbar of 1.5 times to the rating of Incommer switch
gear & for out goings 1.5 times of the individual switch gear duly sleeved with heat shrink sleeve colour coated for 3 Phase,
4 wire electric supply system and control wiring with multistranded PVC insulated copper wire size not less then 1.5 SQMM,
complete comprising with following accessories all as specified and directed by the Engr-in-charge. (Note: Feeder pillar
box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto
40 cm above ground level as directed. The cost of the PCC foundation shall be deemed to be included in the unit rate
quoted for the item). ( Note:-All type Test Certificates and Design varification with switch gears ( ACB & MCCB) as per
confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test at with 4000 Amps 65 KA, should be
submitted by the contractor before executing the job).
INCOMING:-
(i) MCCB 4P 40 A, 10 KA with SPREADER Link -01 Set
(ii) HIGH MAST light controls:-
(iii) Contactor 32 A (AC3), 3P,- 01 No. (iv) Digital AstroTimer - 01 No.
(v) Control MCB SP 6A- 03 Nos. (vi) MCBTP 16-32 A - 02 Nos.
(vii) REV- FWD Starter, 05 HP:- (a) Contactor 12A (AC3), 3P,- 02 Nos.
(b) OLR 5-8 A - 01 No. (c) Push button( ON/OFF, Rev/ Fwd)- 04 Nos.
(d) Indicator UP/ DOWN- 02 Nos.
39.00 S&F of LED flood light Fitting 210 watt LED, suitable for mounting on High Mast Light structure, IP-65 protection, single 8.00 Each 0.00 INR Zero Only
peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover
for lamp and control gear compartment with high voltage surge protection device up to 5 KV, with bolts,nuts & washers
etc complete all as specified and directed by the Engg-in-Charge.
40.00 S&F in replacement 3.15mm dia MS wire 75x75mm mesh, made up into mattress or cages appx 2.00 mtr height and fixed 25.00 Sqm 0.00 INR Zero Only
with flate iron/angle by welding in position complete all as specified and directed by the Engg-in-Charge.
41.00 Supply, laying and testing cable XLPE insullated, screened, PVC bedded, galvanized steel strip or wire armoured, electric 322.00 RM 0.00 INR Zero Only
power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core complete all as
specified and directed by the Engg-in-Charge.
42.00 Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI 30.00 RM 0.00 INR Zero Only
pipe 40 to 80mm bore and making good both ends complete all as specified and directed by the Engg-in-Charge.
43.00 Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the
placing of work order and shall be verified by the Engr-in-charge