Product Catalogue

[2002-04]

®
Product Catalogue

1 Portable Instruments and Software for Condition Monitoring


2 Continuous Monitoring Systems
3 Adapters, Transducers, and Tools
4 Accessories for Remote Monitoring
5 Cables, Connectors, and Tools
6 Vibration Monitoring Instruments
7 Diagnostic Tools for Maintenance
8 Machine Alignment System and Shims
9 Instruments Approved for Potential Explosive Atmosphere
10 Special Products

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © SPM Instrument AB
1
Portable Instruments and Software
for Condition Monitoring

71700 B © SPM Instrument AB. ISO 9001 certified.


Machine Condition Analyzer A30

TRA-22 TAD-15
A30

TAD-12
TAD-10
TAD-11
EAR-10

TAD-18

TRA-30 TEN-10
TEN-11
TRV-12
TRV-13
TRV-22 TEM-11
TRV-23

TRX-16 TRX-17
13603 CAS-14 CAS-15

Part Numbers
A30-1 Machine Condition Analyzer A30 Basic Speed monitoring
A30-2 Machine Condition Analyzer A30 Logger TAD-10 Contact adapter for tachometer probe
A30-3 Machine Condition Analyzer A30 Expert TAD-11 Contact center, rpm, short
13603 Communication module TAD-15 Contact center, rpm, long
CAB-31 Computer cable, male 25 pins- female 25 pins TAD-12 Contact wheel, meter / min.
CAB-32 Computer cable, male 25 pins- female 9 pins TAD-13 Contact wheel, yards / min.
CAS-14 Carrying case TAD-17 Contact wheel, feet / min.
CAS-15 Carrying case with foam insert TAD-14 Reflecting tape, pad of 5 sheets
EMD-13 Carrying strap TAD-16 Reflecting tape for thin shafts, 5 sheets
FUP-02 Follow-up form for A30, pad of 25 (mm) TAD-18 Tachometer probe with cable
FUP-04 Follow-up form for A30, pad of 25 (inch)
Temperature monitoring
Shock pulse monitoring TEN-10 Temperature probe tip, surface
TRA-20 Quick conn. transducer for measuring stud TEN-11 Temperature probe tip, liquid
TRA-22 Shock pulse transducer, probe assembly TEM-11 Temperature probe with cable
TRA-30 Shock pulse transd. with quick connector
EAR-10 Earphone in eardefenders, headset, incl. cable Spare parts
EAR-11 Earphone in eardefenders, for helmet, incl. cable 13108 Sleeve for probe tip (TRA-22)
CAB-07 Cable for remote monitoring, 1.5 m (6 ft) CAB-02 Cable for TRA-20, 1.5 m (5 ft)
CAB-06 Cable for TRA-22, 1.5 m (5 ft)
Vibration monitoring CAB-10 Spiral cable for TAD-18, TEM-11
TRV-12 Vibration transducer M8 (0-1000 Hz) CAB-30 Cable for TRA-30
TRV-13 Vibration transducer UNF 1/4"-28 (0-1000 Hz) 90022 Battery 1.5 V, alcaline, AA-cell
TRV-22 Vibration transducer M8 (0-5000 Hz)
TRV-23 Vibration transducer UNF 1/4"-28 (0-5000 Hz)
TRX-16 Magnetic foot for vibration transducer
TRX-17 Probe for vibration measurement
VIC-19 Cable for vibration transducer, 1.5 m

SPM Instrument AB • Box 504 • S-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2002-04. TD-119.B
Machine Condition Analyzer A30

PC connection
A30-1 A30-2
25 pole
Basic Logger
female plug
CAB-31
A30-3
Expert 9 pole
female plug
13603 CAB-32

CAB-10

A30 is a machine condition analyzer designed for a reliable preven- Shock pulse (SPM® LR/HR)
tive maintenance of industrial machines. A30 is available in three Measuring range: –19 to 99 dBsv
versions. With ”Basic”, measuring results are recorded manually.
Resolution: 1 dBsv
”Logger” is a data logger and works together with SPM software
Accuracy: ± 1 dBsv
Condmaster®Pro. ”Expert” has all the logger features. In addition,
it uses the EVAM® method for vibration analysis. A ”Basic” version
can be upgraded to ”Logger” and ”Expert”.
Vibration severity (ISO 10816)
Measuring range: 0.5 to 49.9 mm/s RMS
Measuring techniques Analyzer A30 (0.02 to 2.0 in/s RMS)
and other features Basic Logger Expert Resolution: 0.1 mm/s (0.01 in/s)
Shock pulse, LR/HR • • • Accuracy: ± (0.2 mm/s + 2% of reading)
Vibration severity, ISO 10816 • • • Frequency range: 3 to1000 Hz
Temperature measurement • • •
Speed, contact and optical • • • Speed measurement
Continuous reading • • • Measuring range: 10 to 19 999 rpm optical
Data logging with Condmaster®Pro • • Measuring distance: max. 0.6 m (2 ft.)
Measuring point identification with CondIDTM • • Resolution: 1 rpm
Alternative measuring systems • • ± (1 rev. + 0.1% of reading)
Selectable comments • • Accuracy:
Display of check points • •
Long time recording • • Temperature measurement
Vibration spectrum • Measuring range: –50 to +440 °C (–58 to 824 °F)
Evaluated vibration analysis (EVAM) • Resolution: 1 °C (1 °F)

Alternative measuring systems


Instrument specifications
No. per meas.point: 2
General features: language selection, battery test,
Additional information: date / time and comments
continuous reading, transducer line
test, automatic idle / power off
Long time recording
Temperature range: 0 to 50 °C (32 to 120 °F)
Measuring parameters: SPM, VIB, temperature/speed
Power supply: 6 x 1.5 V LR6 alkaline cells
Measuring interval: adjustable 0 to 60 minutes
Battery life: power down 1 year, or 5000 typical
measurements, or continuous
recording 50 hours Vibration analysis (EVAM®)
Size: 255 x 105 x 60 mm (10 x 4.2 x 2.4 in) Window: Hanning
Weight: 0.85 kg (1.9 lb.) Number of samples: 1024 / 2048
Casing / protective cover: ABS / polyurethane FFT result: 400 / 800 spectrum lines
Keypad: sealed membrane Range, resolution 3 to 200 Hz, 0.5 / 0.25 Hz
Display: LCD, 4x16 characters, LED backlight, at 400 / 800 lines: 3 to 500 Hz, 1.25 / 0.625 Hz
adjustable, automatic on/off 3 to 1000 Hz, 2 .5 / 1.25 Hz
3 to 2000 Hz, 5.0 / 2.5 Hz
Memory: typical 500, max. 999 meas. points
3 to 5000 Hz, 12.5 / 6.25 Hz
Backup, memory/clock: approx. 24 hours
Lines displayed: 15 highest, toggle Hz / cpm
Meas. point identification: read and write to CondIDTM
Lines saved: 1 to 200 highest
Reading distance: max. 50 mm

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2001-01. TD-113.B
Machine Condition Tester T30

TRA-22 TAD-15

T30
TAD-12
TAD-10
TAD-11
EAR-10

TAD-18

TRA-30 TEN-10
TEN-11
TRV-12
TRV-13
TRV-22 TEM-11
TRV-23

TRX-16 TRX-17
13603 CAS-14 CAS-15

Part Numbers
T30-1 Machine Condition Tester T30 Basic Speed monitoring
T30-2 Machine Condition Tester T30 Logger TAD-10 Contact adapter for tachometer probe
T30-3 Machine Condition Tester T30 Expert TAD-11 Contact center, rpm, short
13603 Communication module TAD-15 Contact center, rpm, long
CAB-31 Computer cable, male 25 pins- female 25 pins TAD-12 Contact wheel, meter / min.
CAB-32 Computer cable, male 25 pins- female 9 pins TAD-13 Contact wheel, yards / min.
CAS-14 Carrying case TAD-17 Contact wheel, feet / min.
CAS-15 Carrying case with foam insert TAD-14 Reflecting tape, pad of 5 sheets
EMD-13 Carrying strap TAD-16 Reflecting tape for thin shafts, 5 sheets
FUP-01 Follow-up form for T30, pad of 25 (mm) TAD-18 Tachometer probe with cable
FUP-03 Follow-up form for T30, pad of 25 (inch)
Temperature monitoring
Shock pulse monitoring TEN-10 Temperature probe tip, surface
TRA-20 Quick conn. transducer for measuring stud TEN-11 Temperature probe tip, liquid
TRA-22 Shock pulse transducer, probe assembly TEM-11 Temperature probe with cable
TRA-30 Shock pulse transd. with quick connector
Spare parts
EAR-10 Earphone in eardefenders, headset, incl.cable
13108 Sleeve for probe tip (TRA-22)
EAR-11 Earphone in eardefenders, for helmet, incl. cable
CAB-02 Cable for TRA-20, 1.5 m (5 ft)
CAB-07 Cable for remote monitoring, 1.5 m (6 ft)
CAB-06 Cable for TRA-22, 1.5 m (5 ft)
Vibration monitoring CAB-10 Spiral cable for TAD-18, TMM-11
TRV-12 Vibration transducer M8 (0-1000 Hz) CAB-30 Cable for TRA-30
TRV-13 Vibration transducer UNF 1/4"-28 (0-1000 Hz) 90022 Battery 1.5 V, alcaline, AA-cell
TRV-22 Vibration transducer M8 (0-5000 Hz)
TRV-23 Vibration transducer UNF 1/4"-28 (0-5000 Hz)
TRX-16 Magnetic foot for vibration transducer
TRX-17 Probe for vibration measurement
VIC-19 Cable for vibration transducer, 1.5 m

SPM Instrument AB • Box 504 • S-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2002-04. TD-120.B
Machine Condition Tester T30

PC connection
T30-1 T30-2
25 pole
Basic Logger
female plug
CAB-31
T30-3
Expert 9 pole
female plug
13603 CAB-32

CAB-10

T30 is a machine condition tester designed for a reliable preventive Shock pulse (SPM® dBm/dBc)
maintenance of industrial machines. T30 is available in three Measuring range: –9 to 99 dBsv
versions. With ”Basic”, measuring results are recorded manually.
Resolution: 1 dBsv
”Logger” is a data logger and works together with SPM software
Condmaster®Pro. ”Expert” has all the logger features. In addition, Accuracy: ± 1 dBsv
it uses the EVAM® method for vibration analysis. A ”Basic” version
can be upgraded to ”Logger” and ”Expert”. Vibration severity (ISO 10816)
Measuring range: 0.5 to 49.9 mm/s RMS
(0.02 to 2.0 in/s RMS)
Measuring techniques Tester T30
and other features Basic Logger Expert Resolution: 0.1 mm/s (0.01 in/s)
Shock pulse, dBm/dBc • • • Accuracy: ± (0.2 mm/s + 2% of reading)
Vibration severity, ISO 10816 • • • Frequency range: 3 to 1000 Hz
Temperature measurement • • •
Speed, contact and optical • • • Speed measurement
Continuous reading • • • Measuring range: 10 to 19 999 rpm optical
Data logging with Condmaster®Pro • • Measuring distance: max. 0.6 m (2 ft.)
Measuring point identification with CondIDTM • • Resolution: 1 rpm
Alternative measuring systems • • Accuracy: ± (1 rev. + 0.1% of reading)
Selectable comments • •
Display of check points • •
Long time recording • • Temperature measurement
Measuring range: –50 to +440 °C (–58 to +824 °F)
Vibration spectrum •
Evaluated vibration analysis (EVAM) • Resolution: 1 °C (1 °F)

Alternative measuring systems


Instrument specifications No. per meas.point: 2
General features: language selection, battery test, Additional information: date / time and comments
continuous reading, transducer line
test, automatic idle / power off
Long time recording
Temperature range: 0 to +50 °C (32 to 120 °F)
Measuring parameters: SPM, VIB, temperature/speed
Power supply: 6 x 1.5 V LR6 alkaline cells
Measuring interval: adjustable 0 to 60 minutes
Battery life: power down 1 year, or 5000 typical
measurements, or continuous
Vibration analysis (EVAM®)
recording 50 hours
Size: 255 x105 x 60 mm (10 x 4.2 x 2.4 in) Window: Hanning

Weight: 0.85 kg (1.9 lb) Number of samples: 1024 / 2048

Casing / protective cover: ABS / polyurethane FFT result: 400 / 800 spectrum lines

Keypad: sealed membrane Range, resolution 3 to 200 Hz, 0.5 / 0.25 Hz


Display: LCD, 4x16 characters,LED backlight, at 400 / 800 lines: 3 to 500 Hz, 1.25 / 0.625 Hz
adjustable, automatic on/off 3 to 1000 Hz, 2 .5 / 1.25 Hz
3 to 2000 Hz, 5.0 / 2.5 Hz
Memory: typical 500, max. 999 meas. points 3 to 5000 Hz, 12.5 / 6.25 Hz
Backup, memory/clock: approx. 24 hours
Lines displayed: 15 highest, toggle Hz / cpm
Meas. point identification: read and write to CondIDTM
Lines saved: 1 to 200 highest
Reading distance: max. 50 mm

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-10. TD-114.B
CondIDTM, Condition Memory

6
Distance

45
max. 50 mm

30

CondIDTM is a contact free RF transponder used for measur-


ing point recognition and condition memory. It is mounted
on the adapter cap or strapped in a suitable place on the
machine. It should not be placed directly on metal surface. CAP-01
A distance of min. 3 mm between metal surface and CondIDTM
is recommended. It is used with Leonova and the “Logger” Measuring
and “Expert” versions of Tester T30 and Analyzer A30. adapter

CondIDTM is responds to a recognition signal when an SPM


datalogger is held close to the tag. It contains all basic data
for its measuring point: number, name, and all measuring
techniques connected with it. If the measuring point is al-
ready loaded in the datalogger, it will be displayed, else it
will be added to those in the data logger memory, pro-
grammed with all measuring techniques. CondIDTM also saves
the measuring results when the WRITE function is used after
taking the readings.

SPM data loggers automatically receive a communication


code from Condmaster®Pro 2.0 when a measuring round is
downloaded. Using the WRITE function, the data for the Specifications:
displayed measuring point are sent to the tag. This links it to
Memory: 116 bytes
the measuring point. On uploading the round to Cond-
master®Pro, the measuring point is marked with a CondIDTM Resonance frequency: 125 ± 6 kHz
icon. To break the link, one simply removes this icon before Reading distance: max. 50 mm
downloading the point. The tag can then be linked with
Material: Glass fibre reinforced epoxy
another point.
Protection class: IP66
All tags are safeguarded and can only be read with SPM
Operating temperature -40 to 85 °C
instruments. In addition, the user can set read and write
passwords in Condmaster®Pro. These passwords are auto- Environment: Suitable for indoors and
matically sent to data logger and tag. outdoors use

The tag memory is 116 characters. If this is exceeded, e.g. Dimensions: 30 x 45 x 2 mm


by long measuring point names, a menu will show that Part number: SPM 14489
exceeding data is excluded, starting with truncating the
measuring point name. The user can then edit the measur-
ing point data to fit the tag memory.

SPM Instrument AB • Box 504 • S-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2002-04. TD-151.B
Condmaster®Pro 2.0

Condmaster®Pro is a comprehensive condition monitoring Condmaster®Pro is available for single users and for net-
and predictive maintenance program. works (Windows compatible). It has functions for data im-
port and export. The program works under Windows 2000
Condmaster®Pro: and NT (also 95 and 98 for single user PC) and uses SQL
• stores data and evaluates measuring results from all Server 7.0 as data base handler, included on the installation
SPM instruments for periodic bearing condition, disks.
including EVAM® vibration analysis and ISO vibration
severity measurements. The CMS System
• communicates with all SPM data logging instruments. Condmaster®Pro can handle up to 9 CMS Systems, each
consisting of up to 250 measuring units: BMS (for shock
• controls the CMS System for continuous condition
pulse measurement, 16 channels), AMS (analog signals, 16
monitoring.
channels), and VMS (vibration, 8 channels). These are indi-
• accepts and presents data from any customer defined vidually configured regarding measuring time, measuring
measuring technique. sequence, alarm delays, relay settings, etc. Each such sys-
• administers measuring, lubrication, inspection, and tem is connected via local area network (LAN) and a system
other maintenance routines. unit.
• contains a bearing catalogue and the program
In addition, Condmaster®Pro controls VCM units for vibra-
LUBMASTER to simulate bearing life expectancy under
tion analysis (EVAM®), connected via PC network. VCM
various lubrication conditions.
units have processors, hard disks and multiplexing measur-
• has a user defined graphical display of the measuring ing logic. Measuring assignments defining frequency range,
point locations with alarm flags and colour coded FFT analysis, speed measurements, etc. are set up in
condition messages. Condmaster®Pro, which also stores and presents the analy-
sis results.
Condmaster®Pro stores basic data on machines and meas-
uring points, using a customer defined numbering system. Hardware Requirements:
Each measuring point can be set up for shock pulses, vibra-
• PC with Pentium II min. 233 Hz, 64 Mb RAM
tion severity, vibration analysis, temperature, two customer
and 250 Mb hard disk
defined measurements, constant or measured machine
• Windows 2000 (95, 98), NT (not tested for XP nor ME)
speed, a lubrication check plus one other condition check.
The number of measuring points is only limited by hard disk • Video adapter SVGA, 600 x 800 pixels.
capacity. Work descriptions can be attached to individual
points, to monitoring routes, and to work orders. The pro- Program versions
gram produces time based work orders and check lists as Condmaster®Pro is available as a complete program and
well as alarm lists and graphic displays of measuring results. also in selective versions, e. g. for hand-held instruments
with and without data logging and vibration analysis, or for
the CMS System only.

SPM Instrument AB • Box 504 • S-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2002-04. TD-153.B
2
Continuous Monitoring Systems

71700 B © SPM Instrument AB. ISO 9001 certified.


Machine Guard MG4-1

Machine Guard MG4-1 is a stand-alone measuring unit for Technical specifications


continuous monitoring of machine vibration on one chan- Vibration channels: 1
nel. It measures vibration severity (true RMS value of vibra-
Analog outputs (1): 4 - 20 mA, selective range,
tion velocity) according to ISO 10816. no galvanic separation
Machine Guard MG4-1 provides: Main relay (1): 250 Vac, 5 A, 1250 VA
Secondary relays (2): 125 Vac, 1 A, 60 VA,
• Two programmable alarm levels and status display 150 Vdc, 1 A, 30 W
(green - yellow - red light) Power supply: 230 Vac, 115 Vac or
• Display of measured value with continuous updates 15 to 30 Vac/Vdc
• Analog output 4 - 20 mA with programmable range in Power consumption: max. 6 VA
steps of 10 mm/s RMS Temperature range: 0° to 50° C (32° to 122° F)
• Relays 250 V (1) and 125 V (2) with programmable Casing: Polycarbonate/PVC, IP65
alarm levels. Display screen: LCD, 4 x 16 characters, back-
lighted
MG4-1 has a casing for wall mounting, IP65. It can be
Status display: Green, yellow, red LED
supplied with mains power or be connected to a PLC.
Measuring time, alarm levels, alarm delay and the channel/ Dimensions: 200 x 144 x 77 mm
relay combinations are programmed, using the push buttons Weight: 1060 grams
on the front panel.
Vibration channel (VIB)
The following options are selected on ordering the unit:
Measuring range: 0.5 to 49.9 mm/s RMS
Power supply: (0 to 1.9 inch/s RMS)
• 230 Vac, 115 Vac or 15 to 30 Vac/Vdc Resolution: 0.1 mm/s (0.01 inch/s)
Frequency, lower limit: 3, 10, or 100 Hz
Vibration channel:
Frequency, upper limit: 1000 or 2000 Hz
• Lower frequency range 3, 10 or 100 Hz
Measuring time: Programmable 1 to 15 s
• Upper frequency range 1000 or 2000 Hz
Alarm limits: 2, programmable
• Modification for vibration transducers without pre-
amplifier (TRV-01, TRV-12/13) Alarm delay: 0 to 600 seconds, steps of 2 s
Fault indication: Transducer line test for short
and open circuit
Transducer type: TRV-18/19 or TRV-20/21 with
isolated installation foot
TRX-18/19

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2001-01. TD-141B
Machine Guard MG4-2

Machine Guard MG4-2 is a stand-alone measuring unit for Technical specifications


continuous monitoring of machine vibration on two chan- Vibration channels: 2, multiplexing
nels. It measures vibration severity (true RMS value of vibra-
Analog outputs (2): 4 - 20 mA, selective range,
tion velocity) according to ISO 10816. no galvanic separation
Main relay (1): 250 Vac, 5 A, 1250 VA
Machine Guard MG4-2 provides:
• Two programmable alarm levels per channel and status Secondary relays (4): 125 Vac, 1 A, 60 VA,
150 Vdc, 1 A, 30 W
display (green - yellow - red light)
Power supply: 230 Vac, 115 Vac or
• Display of measured value with continuous updates 15 to 30 Vac/Vdc
• Analog output 4 - 20 mA with programmable range in Power consumption: max. 6 VA
steps of 10 mm/s RMS Temperature range: 0° to 50° C (32° to 122° F)
• Relays 250 V (1) and 125 V (4) with programmable Casing: Polycarbonate/PVC, IP65
alarm levels. Display screen: LCD, 4 x 16 characters, back-
lighted
MG4-2 has a casing for wall mounting, IP65. It can be
Status display: Green, yellow, red LED
supplied with mains power or be connected to a PLC.
Measuring time, alarm levels, alarm delay and the channel/ Dimensions: 200 x 144 x 77 mm
relay combinations are programmed, using the push buttons Weight: 1070 grams
on the front panel.
Vibration channel (VIB)
The following options are selected on ordering the unit:
Measuring range: 0.5 to 49.9 mm/s RMS
Power supply: (0 to 1.9 inch/s RMS)
• 230 Vac, 115 Vac or 15 to 30 Vac/Vdc Resolution: 0.1 mm/s (0.01 inch/s)
Frequency, lower limit: 3, 10, or 100 Hz
Vibration channel:
Frequency, upper limit: 1000 or 2000 Hz
• Lower frequency range 3, 10 or 100 Hz
Measuring time: Programmable 1 to 15 s
• Upper frequency range 1000 or 2000 Hz
Alarm limits: 2, programmable
• Modification for vibration transducers without pre-
amplifier (TRV-01, TRV-12/13) Alarm delay: 0 to 600 seconds, steps of 2 s
Fault indication: Transducer line test for short
and open circuit
Transducer type: TRV-18/19 or TRV-20/21 with
isolated installation foot
TRX-18/19

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2001-01 TD-142B
Machine Guard MG4-12

Machine Guard MG4-12 is a stand-alone measuring unit for Technical specifications


continuous monitoring of machine vibration (one channel) Vibration channels: 1
and bearing condition (two channels). It measures vibration SPM channels: 2, multiplexing
severity (true RMS value of vibration velocity) according to Analog outputs (3): 4 - 20 mA, selective range,
ISO 10816 and shock pulses according to the true SPM no galvanic separation
method. Main relay (1): 250 Vac, 5 A, 1250 VA
Secondary relays (4): 125 Vac, 1 A, 60 VA,
Machine Guard MG4-12 provides: 150 Vdc, 1 A, 30 W
• Two programmable alarm levels per channel and status Power supply: 230 Vac, 115 Vac or
display (green - yellow - red light) 15 to 30 Vac/Vdc
Power consumption: max. 6 VA
• Display of measured value with continuous updates
Temperature range: 0° to 50° C (32° to 122° F)
• Analog output 4 - 20 mA with programmable range in Casing: Polycarbonate/PVC, IP65
steps of 10 mm/s RMS (VIB) or 10 dB (SPM) Display screen: LCD, 4 x 16 characters, back-
• Relays 250 V (1) and 125 V (4) with programmable lighted
alarm levels. Status display: Green, yellow, red LED
Dimensions: 200 x 144 x 77 mm
MG4-12 has a casing for wall mounting, IP65. It can be Weight: 1140 grams
supplied with mains power or be connected to a PLC. Vibration channel (VIB)
Measuring time, alarm levels, alarm delay and the channel/ Measuring range: 0.5 to 49.9 mm/s RMS
relay combinations are programmed, using the push buttons (0 to 1.9 inch/s RMS)
on the front panel. Resolution: 0.1 mm/s (0.01 inch/s)
Frequency, lower limit: 3, 10, or 100 Hz
The following options are selected on ordering the unit: Frequency, upper limit: 1000 or 2000 Hz
Measuring time: Programmable 1 to 15 s
Power supply:
Alarm limits: 2, programmable
• 230 Vac, 115 Vac or 15 to 30 Vac/Vdc
Alarm delay: 0 to 600 seconds, steps of 2 s
Fault indication: Transducer line test for short
Vibration channel:
and open circuit
• Lower frequency range 3, 10 or 100 Hz
Transducer type: TRV-18/19 or TRV-20/21 with
• Upper frequency range 1000 or 2000 Hz isolated installation foot
TRX-18/19
• Modification for vibration transducers without pre-
amplifier (TRV-01, TRV-12/13) Bearing channel (SPM)
SPM method: dBm/dBc or LR/HR, evaluated
Bearing channel: Measuring range: 0 to 99 dBsv
• dBm/dBc or LR/HR technique Resolution: 1 dBsv
Alarm limits: 2, programmable
Alarm delay: 0 to 600 seconds, steps of 2 s
Fault indication: Transducer line test of
measuring circuit quality
Transducer type: SPM 40000 or 42000

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2001-01. TD-143.B
Machine Guard MG4-22

Machine Guard MG4-22 is a stand-alone measuring unit for Technical specifications


continuous monitoring of machine vibration (two channels) Vibration channels: 2, multiplexing
and bearing condition (two channels). It measures vibration SPM channels: 2, multiplexing
severity (true RMS value of vibration velocity) according to Analog outputs (4): 4 - 20 mA, selective range,
ISO 10816 and shock pulses according to the true SPM no galvanic separation
method. Main relay (1): 250 Vac, 5 A, 1250 VA
Secondary relays (4): 125 Vac, 1 A, 60 VA,
Machine Guard MG4-22 provides: 150 Vdc, 1 A, 30 W
• Two programmable alarm levels per channel and status Power supply: 230 Vac, 115 Vac or
display (green - yellow - red light) 15 to 30 Vac/Vdc
Power consumption: max. 6 VA
• Display of measured value with continuous updates
Temperature range: 0° to 50° C (32° to 122° F)
• Analog output 4 - 20 mA with programmable range in Casing: Polycarbonate/PVC, IP65
steps of 10 mm/s RMS (VIB) or 10 dB (SPM) Display screen: LCD, 4 x 16 characters, back-
• Relays 250 V (1) and 125 V (4) with programmable lighted
alarm levels. Status display: Green, yellow, red LED
Dimensions: 200 x 144 x 77 mm
MG4-22 has a casing for wall mounting, IP65. It can be Weight: 1150 grams
supplied with mains power or be connected to a PLC. Vibration channel (VIB)
Measuring time, alarm levels, alarm delay and the channel/ Measuring range: 0.5 to 49.9 mm/s RMS
relay combinations are programmed, using the push buttons (0 to 1.9 inch/s RMS)
on the front panel. Resolution: 0.1 mm/s (0.01 inch/s)
Frequency, lower limit: 3, 10, or 100 Hz
The following options are selected on ordering the unit: Frequency, upper limit: 1000 or 2000 Hz
Measuring time: Programmable 1 to 15 s
Power supply:
Alarm limits: 2, programmable
• 230 Vac, 115 Vac or 15 to 30 Vac/Vdc
Alarm delay: 0 to 600 seconds, steps of 2 s
Fault indication: Transducer line test for short
Vibration channel:
and open circuit
• Lower frequency range 3, 10 or 100 Hz
Transducer type: TRV-18/19 or TRV-20/21 with
• Upper frequency range 1000 or 2000 Hz isolated installation foot
TRX-18/19
• Modification for vibration transducers without pre-
amplifier (TRV-01, TRV-12/13) Bearing channel (SPM)
SPM method: dBm/dBc or LR/HR, evaluated
Bearing channel: Measuring range: 0 to 99 dBsv
• dBm/dBc or LR/HR technique Resolution: 1 dBsv
Alarm limits: 2, programmable
Alarm delay: 0 to 600 seconds, steps of 2 s
Fault indication: Transducer line test of
measuring circuit quality
Transducer type: SPM 40000 or 42000

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2001-01. TD-144.B
CMM System Components

BMM-40 BDM-40 BMM-42 BDM-42 DMM-11 DMM-10A


Bearing Monitoring

SPM 40000

45011-L (max. 4 m)
90296-L
90297-L
45011-L (max.100 m)
SPM 42000
VMM-14/15 VMM-20/21 VDM-14/15 VDM-20/21

Vibration Monitoring
TMM-10
Temperature
TRV-18/19

TRX-18/19 45011-L (max. 50 m) to PLC

The CMM System Vibration Monitoring Modules


The CMM system is a permanently installed, continuous VMM-14 1 channel, 10-1000 Hz
condition monitoring system, consisting of transducers, con- VMM-15 1 channel, 3 -1000 Hz
verters, and combined display and control modules.
VMM-20 2 channels, 10-1000 Hz
The transducers measure bearing condition (shock pulse VMM-21 2 channels, 3 -1000 Hz
method), vibration severity (ISO 10816), and temperature. VDM-14 1 channel with display, 10-1000 Hz
The converters, with or without display of measured value, VDM-15 1 channel with display, 3 -1000 Hz
transform the shock pulse and vibration transducer signals VDM-20 2 channels with display, 10-1000 Hz
into 4 to 20 mA analog signals. The temperature transducer VDM-21 2 channels with display, 3 -1000 Hz
has an output of 4 to 20 mA.
TRV-18 Vibration transducer, M8
The display modules (DMM) have two input channels for 4 TRV-19 Vibration transducer, UNF 1/4"
to 20 mA, and two relay outputs (24 V / 100 mA). TRX-18 Insulation foot for vibration transducer TRV-18
TRX-19 Insulation foot for vibration transducer TRV-19
Bearing Monitoring Modules 45011-L Coaxial cable with connectors, temperature
BMM-40 2 channels, for transducer 40000 range -10° to +70° C, max. length L = 50 m
(max. cable length L = 4 m) 45300-L Coaxial cable with connectors, temperature range
BMM-42 2 channels, for transducer 42000 -40° to +125° C, max. length L = 50 m
(max. cable length L = 100 m) Temperature Monitoring
BDM-40 2 channels with display, for transducer 40000 TMM-10 Temperature transducer, -16° to +120° C
(max. cable length L = 4 m) 90296-L Twinned cable for TMM-10, max. 125° C
BDM-42 2 channels with display, for transducer 42000
(max. cable length L = 100 m)
Condition Display Modules
DMM-10A 2 channels, 4-20 mA in, 2 relays (24 V/100 mA),
40000 Shock Pulse Transducer
for 35 mm DIN rail
42000 Shock Pulse Transducer with matching unit
DMM-11 2 channels, 4-20 mA in, 2 relays (24 V/100 mA),
45011-L Coaxial cable with connectors, temp. range
in cabinet IP 65
-10° to +70°C (L = length in meters)
45300-L Coaxial cable with connectors, temp. range Accessories
-40° to +125° C (L = length in meters) 14141 Cabinet with mounting rails for DMM-10A
14142 Mounting rail, 35 mm DIN, length 357 mm

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-10. TD-108.B
CMM System: Bearing Monitoring Module BMM

Module Transducer Cable length


110 BMM-40 40000 max. 4 m
94 56 BMM-42 42000 max. 100 m

124
109

149
Bearing Monitoring Modules BMM are converters with two Technical data
channels which output 4-20 mA proportional to the un-
Measuring method: SPM dBm, unnormalized maximum
normalized maximum value of the shock pulses measured
on a bearing. The measuring time is approximately 1 sec- value
ond per channel. The measuring range for both channels Measuring channels: 2, multiplexing
together can be jumper set to either 0 to 80 or 20 to 100
dBsv. Measuring range 1: 0 to 80 dBsv
(5 dB /mA, 0.24 mA/dB)
The 4-20 mA current can be supplied to an display module Measuring range 2: 20 to 100 dBsv
of type DMM, to a PLC or to a computer controlled moni- (6.26 dB/mA, 0.16 mA/dB)
toring system (e.g. SPM's CMS System). Measuring time: approx. 1 second per channel
There are two versions: Transducer type: SPM 40000 (BMM-40),
BMM-40 for shock pulse transducer type 40000. The coaxial SPM 42000 (BMM-42)
cable used between transducer and module is max. 4 m.
Transducer cable: coaxial cable, SPM 90005-L, or SPM
BMM-42 for shock pulse transducer type 42000. The coaxial 90267-L (L = length in m)
cable used between transducer and module is max. 100 m.
Analog output: 4 to 20 mA
The modules are wall mounted and supplied with 12 to Fault indication: ≤ 1 mA out = interrupted or faulty
24 V DC. An interruption in the transducer line is indicated
transducer line
by an output of ≤ 1 mA. This function can be eliminated by a
jumper setting, which is separate for each channel. Loop resistance: max. 450 Ω at 12 V, 1.1 kΩ at 24 V
Power supply: 12 to 24V DC ± 10%
Supply current: 0.1 A
Signal conversion Cable inlet: ø 5.5 to 10 mm

mA Housing: polycarbonate, IP65


20 Temperature range: 0° to 55° C
18
Dimensions: 110 x 149 x 56 mm
16
14 Mounting screws: 4 screws, ø 4 mm,
12 spacing 109 x 94 mm
10
Weight: 300 g
8
6
4
0

1: 0 20 40 60 80 dBsv
2: 20 40 60 80 100 dBsv

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-01. TD-145.B
CMM System: Bearing Display Module BDM

Module Transducer Cable length


BDM-40 40000 max. 4 m
110 BDM-42 42000 max. 100 m
94 56

124
109

149
Bearing Display Modules BDM have two functions: Measuring method: SPM dBm, unnormalized maximum
• they measure bearing condition (unnormalized maxi- value
mum value) on two channels and convert the result into Measuring channels: 2, multiplexing
an analog 4-20 mA signal which can be sent to a PLC. Measuring range 1: 0 to 80 dBsv
• they display analog 4-20 mA signals as a 3 digit meas- (5 dB /mA, 0.24 mA/dB)
ured value. All units have two inputs for analog 4-20 Measuring range 2: 20 to 100 dBsv
mA, connected to the LED display, the status lights and (6.26 dB /mA, 0.16 mA/dB)
the alarm relays. The analog signal normally comes Measuring time: approx. 1 second per channel
from the module's measuring channels, but can even
Transducer type: SPM 40000 (BMM-40),
come from external sources.
SPM 42000 (BMM-42)
There are two versions: Transducer cable: coaxial cable, SPM 90005-L,or
BDM-40 for shock pulse transducer type 40000. The coaxial 90267-L (L = length in m)
cable between transducer and module is max. 4 m. Analog output: 4 to 20 mA
BDM-42 for shock pulse transducer type 42000. The coaxial Fault indication: ≤1 mA out = interrupted or faulty
cable between transducer and module is max. 100 m. transducer line

The measuring range for both channels together can be Loop resistance: max. 450 Ω at 12 V, 1.1 kΩ at 24 V
jumper set to either 0 to 80 or 20 to 100 dBsv. The modules Power supply: 12 to 24V DC ± 10%
are wall mounted and supplied with 12 to 24 V DC. An Supply current: 0.15 A
interruption in the transducer line is indicated by an output
of ≤ 1 mA. This function can be eliminated by a jumper Cable inlet: ø 5.5 to 10 mm
setting. Housing: polycarbonate, IP65

The display circuit acts as a programmable ampere meter Temperature range: 0° to 55° C
with two channels. Using two push-buttons, one can select Dimensions: 110 x 149 x 56 mm
preprogrammed measuring units and ranges from a list and
Mounting screws: 4 screws, ø 4 mm, spacing 109 x 94 mm
set two alarm levels (with alarm delay) for each channel.
These are connected to three status lights (green - yellow - Weight: 400 g
red) and to two relay outputs.
Signal to display: 4 to 20 mA, 2 channels
The relays can be controlled by either display channel. In
Relays (2): max. 24 V/100 mA
one channel mode, both relays are slaved to a single display
channel and provide relay switching at two levels (ALERT Value display: 3 digits, red LED
and ALARM). In two channel mode, each display channel Status display: green, yellow, and red LED
uses one relay which switches at the ALARM level. Alarm limits: 2 per input channel, set with push-
buttons
Push-buttons: 2, for display control, alarm limit and
alarm delay setting

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-01. TD-146.B
CMM System: Vibration Monitoring Module VMM

Module Channels Freq. range


VMM-14 1 10 - 1000 Hz
VMM-15 1 3 - 1000 Hz
110
VMM-20 2 10 - 1000 Hz
94 56 VMM-21 2 3 - 1000 Hz
124
109

149
VMM-14/15 VMM-20/21

Vibration Monitoring Modules VMM are programmable Technical data


converters which supply a 4-20 mA signal proportional to Measuring method: vibration severity similar to ISO 10816
the RMS-value of vibration velocity. There are four versions: (modified frequency range, VMM-15/21)
VMM-14: 1 channel, frequency range 10 - 1000 Hz Channels: 1 (VMM-14/15), 2 (VMM-20/21)
VMM-15: 1 channel, frequency range 3 - 1000 Hz
Measuring range, mm/s inch/s mm/s/mA mA/mm/s
VMM-20: 2 channels, frequency range 10 - 1000 Hz
set by 0-5 0-0.19 0.313 3.2
VMM-21: 2 channels, frequency range 3 - 1000 Hz.
DIP switch: 0-10 0-0.39 0.625 1.6
The frequency range of 3 to 1000 Hz is suitable for ma- 0-20 0-0.78 1.25 0.8
chines with rotational speed down to 180 r.p.m. 0-40 0-1.57 2.5 0.4

Frequency range: 10 to 1000 Hz (VMM-14/20)


The measuring range can be DIP switch set to either 0 to 5,
3 to 1000 Hz (VMM-15/21)
0 to 10, 0 to 20 or 0 to 40 mm/s.
Transducer type: TRV-18 / 19
The 4-20 mA output can be supplied to a display module Transducer cable: coaxial cable, SPM 90005-L ,
type DMM, to a PLC or to a computer controlled monitor- or 90267-L, (L = max. 50 m)
ing system (e.g. SPM's CMS System). Analog output: 4 to 20 mA
Transducer line test: <1 mA out for open or short circuit
A transducer line fault causes an output of <1 mA. If this (deselect by jumper)
should interfere with PLC operations, the min. output can Loop resistance: max. 400 Ω at 12 V, 1 kΩ at 24 V
be jumper set to 4 mA, individually for each channel. Power supply: 12 to 24V DC (± 10%, according to
The vibration transducer TRV-18/19 is connected via coaxial EN 50082-2)
cable with TNC connectors. The module is wall mounted Supply current: max 0.1 A
with 4 screws ø 4 mm and supplied with 12 to 24 V DC. The Housing: polycarbonate, IP65
cable inlet is tight for cable diameters 5.5 to 10 mm. Temperature range: 0° to 55° C
Dimensions: 110 x 149 x 56 mm
Cable inlet: ø 5.5 to 10 mm
Mounting screws: 4 screws, ø 4 mm, spacing 109 x 94 mm
Weight: 300 g

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-01. TD-147.B
CMM System: Vibration Display Module VDM

Module Channels Freq. range


VDM-14 1 10 - 1000 Hz
VDM-15 1 3 - 1000 Hz
110 VDM-20 2 10 - 1000 Hz
94 56 VDM-21 2 3 - 1000 Hz
124
109

149
VDM-14/15 VDM-20/21

Vibration Display Modules VDM have two functions: Technical data


• they measure the RMS-value of vibration velocity on Measuring method: vibration severity similar to ISO 10816
one or two channels and convert it to an analog 4-20 (modified lower frequency, VDM-15/21)
mA signal which can be sent to a PLC. Vibration channels: 1 (VDM-14/15), 2 (VDM-20/21)
• they display analog 4-20 mA signals as a 3 digit meas- Measuring range, mm/s inch/s mm/s/mA mA/mm/s
ured value. All units have two inputs for analog 4-20 set by 0-5 0-0.19 0.313 3.2
mA, connected to the display, the status lights and the DIP switch: 0-10 0-0.39 0.625 1.6
alarm relays. The analog signal normally comes from 0-20 0-0.78 1.25 0.8
the unit's measuring channel(s), but can even come 0-40 0-1.57 2.5 0.4
from external sources.
Frequency range: 10 to 1000 Hz (VDM-14/20)
There are four versions: 3 to 1000 Hz (VDM-15/21)
VDM-14: 1 vibration channel, frequency range 10 - 1000 Hz Transducer type: TRV-18 / 19
VDM-15: 1 vibration channel, frequency range 3 - 1000 Hz Transducer cable: coaxial cable, SPM 90005-L , or
VDM-20: 2 vibration channels, frequency range 10 - 1000 Hz 90267-L (L= max. 50 m)
VDM-21: 2 vibration channels, frequency range 3 - 1000 Hz. Analog output: 4 to 20 mA
Transducer line test: <1 mA out for open or short circuit
The vibration transducer TRV-18/19 is connected via coaxial
(deselect by jumper)
cable. The module is wall mounted and supplied with 12 to
Loop resistance: max. 400 Ω at 12 V, 1 kΩ at 24 V
24 V DC. The cable inlet is tight for cable diameters 5.5 to
Power supply: 12 to 24V DC ± 10%
10 mm. A transducer line fault causes an output of <1 mA. If
Supply current: max 0.1 A
this should interfere with PLC operations, the min. output
Housing: polycarbonate, IP65
can be jumper set to 4 mA, individually for each measuring
Temperature range: 0° to 55° C
channel.
Dimensions: 110 x 149 x 56 mm
The display circuit acts as a programmable ampere meter Cable inlet: ø 5.5 to 10 mm
with two channels. Using two push-buttons, one can select Mounting screws: 4 screws, ø 4 mm, spacing 109 x 94 mm
preprogrammed measuring units and ranges from a list and Weight: 400 g
set two alarm levels (with alarm delay) for each channel.
Signal to display: 4 to 20 mA, 2 channels
These are connected to three status lights (green - yellow -
Relays (2): max. 24 V/100 mA
red) and to two relay outputs. The relays can be controlled
Value display: 3 digits, red LED
by either display channel. In one channel mode, both relays
Status display: green, yellow, and red LED
are slaved to a single display channel and provide relay
Alarm limits: 2 per display channel
switching at two levels (ALERT and ALARM). In two channel
Push-buttons: 2, for display control, alarm limit and
mode, each display channel uses one relay which switches
alarm delay setting
at the ALARM level.

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-01. TD-148.B
CMM System: Condition Display Module DMM-10A

80

35
16
71 43

DMM-10A is a condition display module for 4-20 mA analog Technical data


signals. Measured quantities and ranges are selected from a Input channels: 2
preprogrammed list (up to 99 alternatives).
Input signals: 4 to 20 mA
The display module is clipped onto a standard mounting rail
Relays (2): 24V / 100 mA
in a control cabinet or similar, and supplied with 12 to 24 V
DC, source referred to earth. Measuring range: selected to match the signal input

The display module has two input channels and two relay Value display: 3 digits, red LED
outputs. The relays can be controlled by either input chan- Status display: green, yellow, and red LED
nel. In one channel mode, both relays are slaved to a single
input channel and provide relay switching at two levels Alarm limits: 2 per display channel, set with push-
(ALERT and ALARM). In two channel mode, each input buttons
channel uses one relay which switches at a preset ALARM Push-buttons: 2, for display control, alarm limit and
level. alarm delay setting

Programmable parameters for each input channel are the Fault indication: blinking yellow LED = signal below 4
measuring range,the two alarm levels ALERT and ALARM, mA (interrupted input circuit)
and the alarm delay. These are input using two push but-
Power supply: 12 to 24V DC ± 10%
tons. Power failure will not erase the program.
Supply current: max 0.05 A
Condition display is provided by three coloured LEDs. The
green LED is on while measured values are below the ALERT Housing: polyamide, not protected
level. Measured values between ALERT and ALARM on Temperature range: 0° to 55° C
either channel trigger a yellow LED, and a red LED lights up
when a measured value exceeds an ALARM level. A blinking Dimensions: 80 x 71 x 43 mm
yellow LED indicates a system fault (incoming signal below Mounting: clip on to 35 mm DIN rail
4 mA).
Weight: 100 g
The measured value is displayed in red LED (three digits). In
two channel mode the display alternates between the two
channels and shows the channel number followed by the
measured value on this channel.

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1999-12. TD-106.B
CMM System: Condition Display Module DMM-11

110 56
94

124

109

143
DMM-11 is a condition display module for 4-20 mA analog Technical data
signals. Measured quantities and ranges are selected from a Input channels: 2
preprogrammed list (up to 99 alternatives).
Input signals: 4 to 20 mA
The display module can be wall mounted separately or in a
Relays (2): 24V / 100 mA
control cabinet or similar. It is supplied with 12 to 24 V DC.
Measuring range: selected to match the signal input
The display module has two input channels and two relay
outputs. The relays can be controlled by either input chan- Value display: 3 digits, red LED
nel. In one channel mode, both relays are slaved to a single Status display: green, yellow, and red LED
input channel and provide relay switching at two levels
(ALERT and ALARM). In two channel mode, each input Alarm limits: 2 per display channel, set with push-
channel uses one relay which switches at a preset ALARM buttons
level. Push-buttons: 2, for display control, alarm limit and
alarm delay setting
Programmable parameters for each input channel are the
measuring range, the two alarm levels ALERT and ALARM, Fault indication: blinking yellow LED = signal below 4
and the alarm delay. These are input using two push but- mA (interrupted input circuit)
tons. Power failure will not erase the program.
Power supply: 12 to 24V DC ± 10%
Condition display is provided by three coloured LEDs. The Supply current: max 0.05 A
green LED is on while measured values are below the ALERT
level. Measured values between ALERT and ALARM on Cable inlet: ø 5.5 to 10 mm
either channel trigger a yellow LED, and a red LED lights up Housing: polycarbonate, IP 65
when a measured value exceeds the ALARM level. A blink-
Temperature range: 0° to 55° C
ing yellow LED indicates a system fault (incoming signal
below 4 mA). Dimensions: 110 x 143 x 56 mm

The measured value is displayed in red LED (three digits). In Mounting: 4 screws, ø4 mm, spacing 109x94 mm
two channel mode the display alternates between the two Weight: 320 g
channels and shows the channel number followed by the
measured value on this channel.

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1999-12. TD-132.B
CMM System: Temperature Transducer TMM-10

M8
46

5000 57 22

TMM-10 is a temperature transducer with a measuring range


from –16° to 120 °C and an analog output of 4 to 20 mA.
The transducer is mounted in a countersunk M8 hole. It is
supplied with 12 to 24 V DC (see derating curve).

TMM-10 transducers can be connected to DMM, BDM and


VDM units which have display and relay functions or to AMS
measuring units in the CMS System for continuous machine
condition monitoring. min. 15
Countersunk
mounting
hole M8

Derating curve Technical data


Measuring range: –16° to 120 °C
Volt
Output: 4 to 20 mA
25
Inaccuracy: typical 1° C, max. 3° C at 25° C
20 Linearity deviation: 2% +0.5 °C
Long time stability: 0.4 °C
15 Temperature range: –30° to 125° C
Power supply: 12 to 24 V DC, see derating curve
10 Loop resistancemax: 50 (U-7) Ω for U=12 to 24 V DC
-16 0 20 40 60 80 100 120 °C
e.g. 400 Ω at 15 V
Housing: acid proof steel AISI 316
(SS2382), Viton sealing, IP67
Mounting hole: M8 threads, 90° countersunk
Electrical connection
Torque: max. 15 Nm
Cable type: twinned two leader TPC, area
red 0.24 mm2, covering FEP,
+
max. temperature 125 °C,
TMM-10 12-24 V DC
white
SPM 90296-L (L = length in meters)
A –
+ –
4-20 mA

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1999-12. TD-107.B
CMS: System Components

1 2

The CMS System 2. Measuring units


The CMS System is a permanently installed, continuous There are 3 types of measuring units, BMS (bearing moni-
machine condition monitoring system. It can be handled by toring), VMS (vibration severity monitoring) and VCM (vibra-
the SPM software CONDMASTER®, a PC program which tion analysis with the EVAM® method). The BMS and VMS
controls the system and collects, stores, and evaluates the units can be equipped with additional boards for monitor-
measuring results. ing of speed (RPM board) or analogue signals (AMS board).

A CMS system comprises: 1) Transducer line, 2) Measuring A. Bearing monitoring:


units, 3) System unit, and 4) Computer with CONDMASTER®. Measuring unit BMS with 16 bearing channels TD-40
The parts are specified on a number of data sheets (TD)
B. Vibration monitoring:
referred to below.
Measuring unit VMS for 8 vib. channels TD-42
Measuring unit VCM for 8 alt. 24 vib. channels TD-123
1. Transducer line C. RPM monitoring:
A. Bearing monitoring line: RPM board 13490 with 4 channels TD-41
A shock pulse transducer (several alternatives) and a trans- Analogue RPM board 13854 for VMS/BMS TD-87
ducer matching unit (TMU) are connected by coaxial cable D. Monitoring of analogue signals:
to the measuring unit: Analogue board 13863 (AMS measuring unit)
Standard transducer 40000 (40100) + TMU-12 TD-04 with 16 analogue channels TD-84
Transducer 42000 (42100) with built-in TMU TD-05
Isolated transducer 11223-L + TMU 12 TD-06
Ex-proof transducer 42011 (42111), transformer TD-116
3. System unit
Coaxial cables and connectors TD-18 The system unit SYS-10 is the interface
Transducer matching unit TMU-12 TD-55 between the measuring units and the PC.

System unit SYS-10 TD-45


B. Vibration monitoring and analysis:
Computer cables and connectors TD-44
Vibration transducer TRV-10/11 (VMS) TD-63
Vibration transducer TRV-20/21 (VCM) TD-124
Coaxial cables and connectors TD-18
4. Computer with CONDMASTER®
C. RPM monitoring: The system software CONDMASTER®
RPM board installation set TD-41 requires a PC for Windows environment.
Analogue RPM interface SPM 13854 TD-87
SPM CONDMASTER®Pro TD-153
D. Monitoring of analogue signals:
AMS board (0 - 20 mA or 0 - 10 V signals) TD-84

E. Temperature monitoring:
Temperature transducer TMM-10 TD-107

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2001-01. TD-43.B
CMS System: Measuring Unit BMS

248 mm

330 mm

Other channels

72 mm

230 / 115 V AC
Bearing channels 1 - 16
LAN in / out

Bearing monitoring Technical data


Measuring unit BMS is a part of the CMS System for con- Measuring range: LR / HR, -19 to 99 dBSV
tinuous bearing monitoring. A CMS System can contain up Inputs / outputs: 16 bearing monitoring channels,
to 250 measuring units. The BMS unit accommodates up to LAN in / out
16 bearing monitoring channels and is operated under Storage capacity: 960 readings
software control (SPM Condmaster®). Dimensions: 330 x 248 x 72 mm
Weight: 4.5 kg
Each bearing monitoring channel is activated for a pro-
Housing: Stainless steel, neoprene
grammed interval (5 to 42 minutes). Readings are taken in a
gaskets, IP 65
programmed sequence, which can comprise 50 channel num- Cable inlets: Nickel plated brass
bers in any combination. The measuring unit stores up to Temperature: 0° to 55° C (32° to 130° F)
960 readings, i.e. min. 80 hours of readings. These are Mains supply : 230 or 115 V AC ± 10%, 10 VA
transferred to the PC for evaluation and display by
Data cable: Shielded, 4 conductors twisted in
Condmaster®.
pairs, area 0.22 mm2 each. Max.
The measuring unit is designed for wall mounting and has a cable length between measuring
stainless steel housing with neoprene gaskets. It is con- units 1000 m
nected to 230 or 115 V AC (nominal voltage ± 10%, even
load, no excessive spikes).
Ordering numbers
Via data cables, the measuring units are connected in se- BMS-20 Measuring unit with 16 bearing channels
ries, forming one or two local area networks (LAN) con- BMS-21 BMS unit with RPM board, see TD-41
nected to the system unit. The shielded data cable must be BMS-23 BMS unit with AMS board, see TD-84
installed in a suitable electrical environment. 90220-L Data cable, temperature -20° to +70°C,
L = length in meters
A BMS measuring unit can be equipped with extra circuit
boards for measuring speed or analogue signals. They are
specified on other data sheets, see under Ordering num-
bers.

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-02. TD-40.B
CMS System: Measuring Unit VMS

248 mm

330 mm

Other channels

72 mm

Vibration channels 1 - 8 230 / 115 V AC

Relay outputs AL1 - 4 LAN in / out


Control inputs SW1 - 4

Vibration monitoring Technical data


Measuring unit VMS is a part of the CMS System for con- Measuring range: 0 to 100 mm/s RMS
tinuous vibration monitoring. A CMS System can contain up Inputs / outputs: 8 vibration monitoring channels,
to 250 measuring units. The VMS unit accommodates up to LAN in / out, 4 control inputs and
8 vibration monitoring channels. The units are operated 4 relay outputs
under software control (SPM Condmaster®). Each unit has 4 Storage capacity: 1000 readings / channel
relay outputs for e.g. activating machine stop and 4 inputs Dimensions: 330 x 248 x 72 mm
for controlling the relay outputs. Weight: 4.5 kg
Housing: Stainless steel, neoprene gaskets,
The VMS unit measures vibration severity according to ISO
IP 65
2372 (velocity in mm/s RMS, 10 to 1000 Hz). Each vibration Cable inlets: Nickel plated brass
channel is activated for a programmed measuring time (2– Temperature: 0° to 55° C
255 s). Readings are taken in a programmed sequence. The Mains supply : 230 or 115 V AC ± 10%, 10 VA
VMS unit stores up to 1000 readings per channel. These are
Relay: Max. 50 V DC, 10 W alt.
transferred to the PC for evaluation and display by Cond-
Max. 35 V AC, 10 VA
master®.
Data cable: Shielded, 4 conductors twisted in
The measuring unit is designed for wall mounting and has a pairs, area 0.22 mm2 each. Max.
stainless steel housing with neoprene gaskets. It is con- cable length between units 1000 m
nected to a main power of 230 V or 115 V AC (nominal
voltage ± 10%, even load, no excessive spikes).
Ordering numbers
Via data cables, the measuring units are connected in se- VMS-22 VMS measuring unit, 8 vibration channels
ries, forming one or two local area networks (LAN) con- VMS-23 VMS unit with RPM board 13490, see TD-41
nected to the system unit. The shielded data cable must be VMS-24 VMS unit with AMS board, see TD-84
installed in a suitable electrical environment. 90220-L Data cable, temperature -20° to +70°C,
L = length in meter
A VMS measuring unit can be equipped with extra circuit
boards for measuring speed and analogue signals. They are
specified on other data sheets, see under Ordering num-
bers.

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-02. TD-42.B
CMS: Speed Monitoring

RPM Board 13490

Inductive
proximity Measuring Unit
switch
BMS-20 / VMS-22

Automatic speed measurement Technical data, ordering numbers


Speed measurement in connection with a CMS System is Measuring unit BMS-20 with RPM board 13490 installed has
used on machines with variable operating speeds, such as ordering number BMS-21. VMS-22 with installed RPM board
paper machines. The speed data allows for an automatic has ordering number VMS-23.
adjustment of shock pulse evaluation and alarm limits.
RPM board 13490, installation set
Rotational speed (r.p.m.) is measured by mounting an in- 13490 RPM Board (1)
ductive proximity switch close to a rotating machine part, 12832 Spacer screw (5)
and connecting it to RPM board 13490 in the measuring 82204 Cable inlet, nickel plated brass (4)
unit. The RPM board is factory mounted in measuring unit 81166 O-ring (4)
BMS-21 and VMS-23. It can be installed in an existing BMS-
Please note: for BMS-20 without prepared inlet
20 unit with EPROM version 2.0 or higher, or in an exsisting
holes for RPM channels, order separately:
VMS-22 unit.
82127 Cable inlet, grey GAP (4)
The RPM board has four speed channels and measures the
RPM board 13490, data
r.p.m. once per minute. The operating program checks the
Dimensions: w x d x h = 218 x 95 x 15 mm
speed data every 25 seconds.
Channels: 4, with 4 screw connectors each
The r.p.m. can be stored in the system unit, to be used by Temperature: 0° to 55° C
any measuring unit in the CMS System (global speed, max. Range: 1 to 20 000 r.p.m.
8 per system). The r.p.m. can also be used for the monitor- Measuring time: 1 minute
ing channels in the measuring unit which contains the RPM Power supply: from the host board
board (local speed). Speed channel addresses are set in the Output voltage: 15 V DC to proximity switch
operating program SPM Condmaster®. Input pulses: 1 – 15 pulses / revolution

The proximity switch is not normally supplied by SPM. It can Inductive proximity switch
be of PNP or NPN type, input voltage 15 V. It can send from Type: PNP or NPN (ex. Telemecanique XS1/XS2)
one pulse to max. 15 pulses per revolution. The number of
Cable, proximity switch to RPM board
pulses/revolution is set by a DIL switch for each active
PVC type, 3 conductors, area 0,34 mm2 each. Cable length
speed channel.
up to 100 m.

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-07. TD-41.B
Analogue RPM interface SPM 13854

13490

Interface SPM 13854


for transforming
analog RPM signal

Description
The interface is a circuit board that is mounted on the
digital RPM board, SPM no 13490. The interface converts
input analogue RPM signals, in mA or V, from the input
channels to digital measuring pulses suited for the SPM
CMS system.

Each input signal is read per minute. The input signals are
converted to max. 3825 pulses per minute and channel.
The actual number of pulses is proportional to the input
signal in comparison with the set measuring range. The
RPM signal is then adjusted in the CONDMASTER program
so that 3825 pulses corresponds to the maximum possible
RPM value provided by the analogue input signal. The out-
put signals consist of pulse trains proportional to the ana-
logue RPM values.
0
The inputs are connected to the interface input terminals. +15 V
The input signals are interchangeable by means of jumpers Inputs Outputs
between the following measuring ranges:

0-1V 0,2 - 1 V
0 - 10 V 2 - 10 V
Ordering numbers
0 - 20 mA 4 - 20 mA
Mounting kit SPM 13854 consists of:
The outputs are connected to the RPM board through ca- Circuit board 13852 1
bles from the output terminals. Power supply and earth are Jumper 93154 8
connected to their corresponding terminals on the RPM Spacer screw 82329 3
board. 3 spacer screws lock the interface to the RPM board.
Screw MRX 3 x 5 3
Cable MKUX, 90114 0.7 m
Technical data:
Mounting instruction, 71489 1
Dimensions: 83.5 x 69 x 15 mm
Temperature: 0 - 55°C ( 32° to 130° F)
Power supply: 15 V ± 1 V DC via the RPM board
No. of inputs: 4
No. of outputs: 4
Tolerance: ± 5 % of the input signal

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-02. TD-87.B
CMS system with analogue measuring
Analogue board SPM 13863

Max. 16
Analogue
inputs

Measuring unit
BMS-20/VMS-22

Measuring of analogue values Technical data and ordering numbers


The task of the analogue measuring unit of the CMS system Measurement unit BMS-20 with the analogue board SPM
is to read measuring values from max. 16 input analogue 13863 mounted has ordering number BMS-23. VMS-22 with
channels. It is an independent unit, with exception of power analogue board installed has ordering number VMS-24.
supply, consisting of a circuit board which is mounted on
top of the BMS or VMS board by means of a special installa- Analogue board kit SPM 13864
tion set. The board is power supplied through the tag-strip 13863 Analogue board (1)
of the BMS or VMS board. No power supply unit exists. 12832 Spacer screws (7)
Control program is SPM CONDMASTER®. 81166 O-ring (4)
82204 Cable inlet, nickel plated brass (4)
Inputs 82221 Spacer screws (2)
Only one of the input channels can be open at a time. 82226 Screw M3 x 5 (7)
Measuring times, measuring sequence and active channels 93174 Jumper (16)
are selected from the control program. 71496 Mounting instruction
71497 Installation instruction (el)
Filing data
NOTE! You can separately order cable inlets for the BMS-20
During the set measuring time all active channels are scanned
without pre-mounted analogue board :
and measured max. number in increasing order followed by
82127 Cable inlet, grey GAP (4)
the next scanning a. s. o. The measuring takes approx. one
second per channel. The max., min. or average measured Analogue board SPM 13863, data
value on each channel is saved. Dimensions: w x d x h = 236 x 133 x 32 mm
Channels: 16 galvanically separated analogue
Alarm limits inputs with 2 screw connectors each
Each channel has min. and max. value respectively as alarm Temp. range: 0° – 55° C
limit to be set from the control program. Alarm is released if Measuring range: 0 - 20 mA and 4 - 20 mA
these limits are passed. The relay of the SYS unit can then 0 - 1 V and 0 - 10 V
also be activated. The alarms can be tracked and analyzed Measuring time
from "CONDMASTER". for active channel: 1 - 42.5 min.

Communications Parameters controlled from CONDMASTER


The contact with the computer proceeds through the multi- ° Selection of active channels
ple serial transmission of the CMS system in one or two ° Tot. meas. time f. active channels (1 min.-42.5 min.)
local area networks (LAN). Its shielded communication ca- ° Selection of values to be saved
ble should be installed in a suitable electric environment. ° Setting of alarm limits (if used)
° Setting the real time watch.
° Setting of the measurement on and off

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-84.B
CMS: System Unit SYS-10

203

68
187

The system unit SYS-10 is the interface between the meas-


uring units and the computer. It can accommodate up to
250 measuring units, connected in one or two local area Rear panel
networks (LAN).

The system unit is placed close to the computer equipment


(max. cable length 10 m). Via a 9 pin RS-232 serial port, the
system unit is connected to a modem or, normally, directly
to the PC. The transmission rate is set by internal switches,
7 settings from 300 to 19 200 bits/second (baud rate).

On delivery, the unit is set for 230 V AC. An internal connec-


tor can be modified to set the unit for 115 V AC. A mains
power cable is included. Power ON is indicated by a green
230 / 115 V AC LAN 1, 2
light on the front panel, system alarm by a red light. An
external warning circuit, triggered by a system alarm or loss
of power, can be connected via a relay output. The relay (10 Alarm relay RS - 232

VA, 50 V, 0.5 A) is normally closed.

Technical data
Input: 2 LAN channels, max. 250 units
Output: 9 pin RS-232 serial port
Power supply: 230 or 115 V AC, 5 VA
Relay: Max. 10 VA, 50 V, 0.5 A
Transmission rate: 300, 600, 1200, 2400, 4800,
9600, 19200 bps
Casing: ABS, black
Temperature: 0° C to + 55° C (32° to 130° F)
Dimensions: 187 x 203 x 68 mm
(7.5 x 8.1 x 2.7 in)
Weight: 0.9 kg (32 oz)

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-45.B
CMS System: Computer Cables

9 pin female 9 pin female 9 pin female 25 pin male


CAB - 35 CAB - 18

SYS-10 / PC MODEM
SYS-10 PC TXD 3 2 TXD
RXD 2 2 TXD RXD 2 3 RXD
TXD 3 3 RXD GND 5 7 GND
GND 5 5 GND RTS 7 6 DSR
DSR 6 6 DTR CTS 8 20 DTR
DTR 4 4 DSR DSR 6
DTR 4
DCD 1

Fig. 1 Computer Cable CAB-35 Fig. 2 Computer Cable CAB-18

25 pin male 25 pin female

CAB - 17

93162
MODEM PC
TXD 2 2 TXD
RXD 3 3 RXD 9 pin male 25 pin female
GND 7 7 GND
DSR 6 4 RTS
DTR 20 5 CTS CAB-35 PC
6 DSR
20 DTR
8 DCD

Fig. 3 Computer Cable CAB-17 Fig. 4 Cable adapter SPM 93162

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-44.B
Measuring Unit VCM-20 for Evam® Vibration Analysis

360

9 8
1 CPU 11
10

500

460
515
4
2 5
3
6 7

210
400

1. Mains power connection 6. Terminals for vibration transducers


2. Motherboard with 8 vibration, 8 RPM channels 7. Terminals for RPM transducers
3. Tag strip for connecting additional measuring 8. Computer unit
board with 16 vibration channels 9. Mains switch
4. Power supply from computer unit 10. COM port, keyboard, mouse
5. COM1 cable to computer unit 11. Disk drive for 3.5" disks

VCM-20 is a continuous measuring unit for vibration analy- Vibration channels: 8, or 24 with extension board
sis according to the EVAM® method. The unit is equipped
Vibration velocity range: ≤ 50 mm/s
with CPU, hard disk, and multiplexing measuring logic. The
software DAQ, installed on the CPU, controls the measur- Sampling methods: Asynchronous, synchronous with
ing operations, data processing and storage. programmable time averaging
Frequency ranges FFT: 0 to 100, 200, 500, 1000, 2000,
VCM-20 has 8 channels for vibration measurements and 8
5000, 10 000, 20 000 Hz
channels for RPM measurements. An additional circuit board,
SPM 14393, with 16 vibration channels can be mounted on Envelope frequencies: 100, 200, 500, 1000, 2000, 5000,
top of the mother board. As vibration transducers, VCM-20 10 000 Hz
accepts ICP type accelerometers with voltage output. RPM Measurement windows: Rectangle, Hanning, Hamming,
transducers are proximity switches, NPN or PNP. Blackman, Exact Blackman,
Kaiser-Bessel, Flat 4, Parzen,
Via Ethernet, VCM-20 is connected to a computer with the
software Condmaster®Pro and DBL under Windows (95, 98, Welsh
NT). The measuring assignments are set up in Cond- Resolution, lines: 200, 400, 800, 1600, 3200, 6400
master®Pro. The communication program DBL transmits Antialising filter: > 80 dB/octave
measuring assignments to and reads the result file from the
Vibration transducer: TRV-20/21 or ICP type acceler-
VCM-20 unit.
ometers with voltage output,
Technical data nom. sensitivity max. 100 mV/g

Processor: 32 bit, >133 MHz Transducer line test: Short and open circuit (for
transducer TRV-20/21)
Memory: 16 Mb RAM
RPM transducer: Proximity switch, PNP or NPN,
Hard disk capacity: > 1 Gb
supply 12 V DC from VCM-20
Floppy disk drive: 3.5", 1.44 Mb
RPM measuring range: 10 to 60 000 rpm
Interfaces for: Ethernet (RJ45, BNC),
Power supply: 115 / 230 V AC
Monitor (VGA), Mouse (PS2),
Keyboard (PS2) Operating temperature: 0° - 55 C°

Software: SPM software Condmaster®Pro, Housing: Enamelled steel, IP 65


DAQ and DBL under Windows Cable inlets: Nickel plated brass
95, 98, NT Dimensions (w x h x d): 400 x 515 x 210 mm
RPM channels: 8 Weight: approx. 20 kg

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-03. TD-123.B
Optical RPM transducer OPT-10 / OPT-11

OPT-10

ø 22
25 2,5

ø 37 69 L

OPT-11

ø 22
25 2,5
15

ø 4,4
ø 37 77 L

OPT-10 and OPT-11 are optical RPM transducers with their


own light sources. They are mainly intended for measuring
the rotational speed of felts in paper machines. The trans-
ducer emits an electrical pulse each time the felt's align-
ment strip passes in front of it.

The transducers are parts of SPM's CMS System and are


accessories for the VCM-20 measuring unit.

OPT-10 can even measure on soiled felts down to a very low


contrast between the normal felt surface and the strip with-
out making any manual adjustment.

OPT-11 has air connection for cleaning of the front glass. It


is connected to common shop air the pressure of which is
reduced to suitable level.

The transducer can be mounted in different ways, for in-


stance by using a stainless steel tube as holder and cable
protection and joining tube and transducer by measns of a Technical data
coupling. Power supply: 12 V DC
When ordering, please specify desired cable length (L) in Measuring distance: max 100 mm
meters. Signal out: NPN (sink)
Temperature range: 0° – 70° C
Casing: Stainless acid proof steel
AISI 316 / SS 2382
Design: IP65
Cable: Screened, 4 conductors,
area 0.24 mm2

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1999-6. TD-121.B
3
Adapters, Transducers, and Tools

71700 B © SPM Instrument AB. ISO 9001 certified.


Standard Adapters

d = M8 /
UNC 5/16"

Adapters are solid bolts which are mounted in countersunk


and threaded holes in the bearing housings. They form the Mounting hole
min. 15 mm
connecting points for a transducer with quick connector,
TRA-30 and equivalent. CAP-01

Standard adapters are available in two lengths and various


thread sizes, see ordering numbers below. The material is
either stainless steel or zinc-plated steel.

Max. 92 mm

Ordering numbers
The following types of adapters are available:
32000 Zinc-plated, M8
32200 Zinc-plated, M8, extended

33000 Zinc-plated, UNC 5/16"


33200 Zinc-plated, UNC 5/16", extended

32010 Stainless steel, M8 Mounting tools


32210 Stainless steel, M8, extended 82053 Countersink with fixed pilot for M8
81027 Holder for countersink
33010 Stainless steel, UNC 5/16"
81028 Countersink, angle 90°, ø 12 mm
CAP-01 Dust cap for adapters 81031 Pilot for M8
81032 Pilot for UNC 5/16"

To drill the mounting hole, use drill bits:


Technical data 6.9 mm for M8
Material, stainless steel SS 2346 (AISI 303) 6.6 mm for UNC 5/16"
Material, zinc-plated 15 mm Zn Torque the adapter with a torque wrench
Torque 15 Nm and a 17 mm socket (SPM 81086).

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-7. TD-01.B
Dust Cap for Adapters

CAP-01

05

PP

The dust cap CAP-01, made of red polypropene, protects Technical data
the contact surface of standard SPM adapters from dirt, Material: Polypropene (PP)
paint, and damage. Temperature range: -10° to 110 °C
(14° to 230 °F)
A clean and undamaged adapter surface is essential for the
Weight: 1g
correct transmission of shock pulses from the bearing to the
measuring instrument.

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1999-05. TD-138.B
Adapters with lock nut

Adapters with lock nut are solid bolts of stainless steel.


They are intended to replace existing mounting bolts or
screws for protective covers, etc., with a thickness up to 6
mm. Adapters with lock nut are mounted in countersunk
and threaded holes in the bearing housings. They form
connecting points for the transducer with quick connector,
TRA-30 and equivalent.

Adapters with lock nut are available in thread sizes from M8


to M12, see ordering numbers below. The table contains
adapter thread size (d), lock nut threads (dn), and the width
Mounting hole
(n) across the flats of the lock nut.
min. 15 mm

Ordering numbers
32511 d = M8 dn = 12 n = 19
34511 d = M10 dn = 14 n = 19
36511 d = M12 dn = 16 n = 22

Mounting tools
Technical data 82053 Countersink with fixed pilot for M8
Material Stainless steel, SS 2346 81027 Holder for countersink
(AISI 303) 81028 Countersink, angle 90°, ø 12 (M6-M10)
81029 Countersink, angle 90°, ø 15 (M12)
Adapter torque M8 15 Nm 81031 Pilot for M8
Lock nut torque M8 12 Nm 81033 Pilot for M10
81035 Pilot for M12
Adapter torque M10 20 Nm 81086 Socket, 17 mm
Lock nut torque M10 15 Nm
To drill the mounting hole, use drill bits:
Adapter torque M12 30 Nm 6.9 mm for M8
Lock nut torque M12 20 Nm 8.6 mm for M10
10.3 mm for M12
Torque the adapter with a torque wrench and a 17 mm
socket, then the lock nut with a 19 (22) mm long socket.

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1999-6. TD-02.B
Glue-on adapter

13
4
36000
ø16 17
36010

Glue-on adapters have the same measuring characteristics


as threaded adapters and connect to the transducer TRA-
30. They have a flat, circular base with a removable tubular
pin for unloading and fixing, and are attached to the meas-
uring point with a suitable adhesive.

A glue-on adapter can replace the corresponding tapered


adapter:
ø4.0
• on thinwalled housings
min.4.5
• where drilling would affect equipment warranties
(mount without the tubular pin).

r = min. 100 mm
Mounting
Select a measuring point in accordance with the SPM rules.

Use a 4.0 mm drill for the mounting hole and make it 4.5
mm deep. The contact surface has to be plane, clean and Technical data
free from paint. It should be planed with a counterbore,
Material, stainless steel: SS 2346 (AISI 303)
min. diameter 15 mm.
Material, zink-plated: SS 1914, 15 mm Zn
The recommended adhesive is Loctite 638 or similar, to be Seat surface: ø16 mm
applied according to the manufacturer's instruction. Put Tubular pin: Spring steel,
adhesive into the mounting hole as well as onto the adapt- for hole ø 4.0 mm
er's seat surface. To avoid damage to the adapters's con- Weight: 22 g
tact surface, use a mallet of soft material to tap it down into Adhesive: Loctite 638 or similar
the mounting hole and press its seat surface against the
material of the bearing housing. Ordering numbers
36000 Glue-on adapter, zink-plated
If necessary, the adapter can be mounted without the tubu-
36010 Glue-on adapter, stainless steel
lar pin. Press it firmly against the bearing housing until the
adhesive has sufficiently hardened to hold the adapter's
weight. Mounting tools
TOM-11 Counterbore, 16 mm
Wait until the adhesive has completely hardened before 81274 Holder for counterbore
connecting a transducer. 14602 Pilot, 4 mm

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-11. TD-013.B
Standard Shock Pulse Transducers

A M8 /
UNC 5/16"

46.5 11 17
4
61.5

B
ø 11

46.5 58 11

115.5

Standard shock pulse transducers are used in all permanent


SPM installations for bearing monitoring. They are installed Mounting hole Space
min. 15 mm min. 100 mm
in countersunk mounting holes on the bearing housings.

A shock pulse transducer converts the shock pulses emitted SPM 93022
by the bearing into electric signals. A coaxial cable connects
the transducer with a measuring terminal or measuring de-
vice. Max. cable length is 4 m.

Transducer housing and base are made of stainless acid Space min. 75 mm
proof steel, suitable for aggressive environments. Standard
thread size is M8, with UNC 5/16" as an alternative. Stand-
ard length (A) is 61.5 mm. A long transducer (B), length
115.5 mm, is used to reach bearing housings beneath pro-
tective covers.
SPM 93077
The transducer is normally connected with a TNC plug, SPM Max. 57 mm
93022. A TNC angle plug, SPM 93077, can be used in
narrow spaces. To prevent cable corrosion in moist environ-
ments, the coaxial cable must be con-nected with a sealing
TNC plug, SPM 13008.

Ordering numbers
40000 Standard shock pulse transducer, M8
40100 Standard shock pulse transducer, Mounting tools
UNC 5/16"
82053 Countersink with fixed pilot for M8
40001 Standard shock pulse transducer,
81027 Holder for countersink
M8, extended
81028 Countersink, angle 90°, 12 mm dia.
40101 Standard shock pulse transducer,
81031 Pilot for M8
UNC 5/16", extended
81032 Pilot for UNC 5/16"

To drill the mounting hole, use drill bits 6.9 mm for M8, 6.6
Technical data mm for UNC5/16".
Measuring range Max. 100 dBsv
Housing, base Stainless steel, SS 2382 Torque and unscrew the transducer with a torque wrench
Design Sealed and a long 17 mm socket (SPM 81086).
Temperature range -30° C to +150° C
External overpressure Max. 1 MPa (10 bar)
Torque 15 Nm, max. 20 Nm
Connector TNC jack

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-7. TD-04.B
Shock Pulse Transducer with TMU

M8 /
UNC 5/16"

The shock pulse transducer with TMU is used in permanent


SPM installations for bearing monitoring, in cases where the Mounting hole Space
cable length between transducer and measuring unit ex- min. 15 mm min. 115 mm
ceeds 4 m. This allows a cable length of max. 100 m. The
transducer with TMU is installed in a countersunk mounting
hole on the bearing housing, in the same way as a standard
transducer.
SPM 93022
A shock pulse transducer with TMU (TMU = Transducer
Matching Unit) converts the shock pulses emitted by the Space min. 115 mm
bearing into an electric signal, and stabilizes the signal for
transmission via a long cable. A coaxial cable connects the
transducer with a measuring terminal or measuring device.

Transducer housing and base are made of stainless, acid


SPM 13008
proof steel (SS 2382), suitable for aggressive environments.
Thread size is M8, with UNC 5/16" as an alternative.
Space min. 90 mm

The transducer is normally connected with a TNC plug, SPM


93022. In moist environments, the coaxial cable must be
connected with a sealing TNC plug, SPM 13008. A TNC
angle plug, SPM 93077, can be used in narrow spaces.
SPM 93077

Ordering numbers
42000 Shock pulse transducer with TMU, M8
42100 Shock pulse transducer with TMU, UNC 5/16" Mounting tools
82053 Countersink with fixed pilot for M8
81027 Holder for countersink
Technical data 81028 Countersink, angle 90°, 12 mm dia.
Measuring range Max. 100 dBsv 81031 Pilot for M8
Housing, base Stainless steel, SS 2382 81032 Pilot for UNC 5/16"
Design Sealed
Temperature range –30° C to +100° C
To drill the mounting hole, use drill bits 6.9 mm for M8, 6.6
External overpressure Max. 0.7 MPa (7 bar)
mm for UNC 5/16".
Torque 15 Nm, max. 20 Nm
Connector TNC jack Torque and unscrew the transducer with a torque wrench
and a long 17 mm socket (SPM 81086).

SPM Instrument AB• Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-7. TD-05.B
Glue-on Shock Pulse Transducer SPM 40010

ø14
M3
47.5 2.5 - 3 17
40010

Glue-on transducers 40010 can replace standard transduc-


ers on thinwalled bearing housings and on machines where
the drilling of standard mounting holes would affect equip-
ment warranties. They have the same measuring character-
81274
istics as standard transducers, but a flat, circular base which
is glued to the measuring point, and an M3 screw for un-
loading and fixing.

Mounting 81275
ø 2.7
The transducer is mounted against a smooth, flat surface on
the machine. Use a 2.7 mm drill for the mounting hole and ø 15
make it 4.5 mm deep. Always plane the surface with a
14041
counterbore, min. diameter 15 mm.
min.4.5

The recommended adhesive is Loctite 638 or similar. Please


max.1
read the instructions for use and follow them carefully.
Screw the transducer by hand into the mounting hole. The
screw is self-threading. In narrow spaces a 17 mm socket
(SPM 81086) may be used. The torque should not be more
than 1 Nm. Wait until the adhesive has hardened before
connecting the cable.
min. 4.5 min. 100 mm
Technical data
Measuring range: Max. 100 dBsv
Housing, base: Stainless acid proof steel
AISI 316 or SS 2382
Design: Sealed
Temperature range: -30° C to +150° C
External overpressure: Max. 1 MPa (10 bar)
Recommended adhesive: Loctite 638
min. 4.5 min. 75 mm
Connector: TNC
Max. cable length 4m
Weight: 50 g

Tools
14042 Counterbore, complete
81274 Holder for counterbore
81275 Counterbore, diameter 15 mm
14041 Pilot, diameter 2.7 mm
81086 Socket, 17 mm

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-98.B
Shock Pulse Transducers in Bolt Design

M10

SPM
M12

55.5 60 17

115.5

A shock pulse transducer in bolt design is intended to


replace one of the holding bolts of the bearing housing. It
can be used in case there is an uninterrupted signal path
between the bearing and the transducer’s seat surface (A).
This means that the the seat surface (A) of the transducer is
placed directly on the bearing housing. Shock pulses from
the bearing are transmitted via that surface, not via the
threads.

The transducer is mounted against a flat surface, milled and


unpainted, within the load zone of the bearing. Washers
must not be used. The transducer is pierced for a locking
wire, hole diameter 1.5 mm. Space min. 100 mm

Via a coaxial cable with TNC connector, the transducer is


connected to a bearing damage detector or a measuring
terminal for a portable shock pulse meter. In moist environ-
ments, a sealing TNC connector SPM 13008 must be used.
An angle connector SPM 93077 is used in narrow spaces
(min. space requirement 85 mm). Max. cable length is 4 m.
The transducer is torqued with a torque wrench and a long
17 mm nut.

Ordering numbers
41225 Transducer in bolt design, M10
41435 Transducer in bolt design, M12

Technical data
Measuring range Max. 100 dBsv
Mounting tools
Housing, base Stainless steel, SS 2382
81027 Holder for counterbore
Design Sealed
81057 Counterbore, diameter 20 mm
Temperature range -30° C to +150° C
81033 Pilot 8.5 mm (M10)
External overpressure Max. 1 MPa (10 bar)
81035 Pilot 10.2 mm (M12)
Hole for locking wire 1.5 mm dia.
Connector TNC jack
Torque: Max. 20 Nm for M10,
30 Nm for M12

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2001-06. TD-003.B
Special Bolts for Shock Pulse Transducers

14073 14074 14075

Special bolts for shock pulse transducers are used in perma-


nent SPM installations for bearing monitoring. The typical
application is turbo chargers, where they function as hold-
ing bolts for bearing caps and receivers for standard shock
pulse transducers with M8 threads (SPM 40000). SPM 40000

The bolts are made of high-tensile steel and must be SPM 46024-L
mounted without washers. Each bolt is delivered with an
M3 locking screw and an Allen key for this screw.

Technical data Locking


Material: High-tensile steel, ETG100 screw

Locking screw: SK6SS, M3 x 6 No washer!

Turbo Bolt Thread Torque Cable Cable


type Art. no. size max. length (L) Art. no.

VTR 454 14073 M12 110 Nm 450 mm 46024-0.45


VTR 501 14073 M12 110 Nm 550 mm 46024-0.55
VTR 564 14074 M16 220 Nm 550 mm 46024-0.55
VTR 714 14075 M20 350 Nm 650 mm 46024-0.65

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2001-01. TD-102.B
Shock Pulse Transducer with Probe TRA-22

TRA-22

TRA-22 is a hand-held probe, which is used together with


Shock Pulse Tester T2000/T2001 and Shock Pulse Analyzer
A2010/A2011. The probe is directionally sensitive and must
be held aligned against the bearing and not deviate from
this direction by more than ± 5°. The probe tip is Aspring
loaded and moves within a sleeve made of chloroprene
rubber (neoprene) and tolerates 110° C (230° F).

Measuring points for the probe transducer should be lo-


cated directly on the bearing housing and the signal path
should be in a direct line to the contact area. The strongest
shock pulses are emitted from the loaded region of the
rolling interface in the bearing. The loaded region for radial
load covers a sector of ± 45° from the load direction, for
axial load the region is 360°. Since the transfer of shock
pulses to the bearing housing is limited by the width of the
bearing, direct radiation of pulses will be restricted to a BEX-20 BEX-21
sector of ± 60° from the perpendicular to the rolling surface.
Measuring points should be clearly marked, for instance
with the SPM marker BEX-19.

To maintain a steady pressure on the tip, press the probe


tip against the measuring point until the rubber sleeve is in
contact with the surface. Avoid pressing the probe tip against
cavaties and fillets which are smaller than the probe tip.

Ordering numbers
TRA-22 Shock pulse transducer, probe assembly max. 60°
BEX-19 Measuring point marker BEX-19
BEX-20 Center drill
BEX-21 Rotary file

Spare parts
TRA-15 Transducer with probe
BAX-10 Probe handle
CAB-06 Cable for TRA-22
13108 Sleeve for probe tip

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-7. TD-39.B
Shock pulse transducer with quick connector

TRA-30

TRA-30 is a shock pulse transducer with quick connector. It


is used for measurements on permanently installed adapt-
ers. The quick connector forms a bayonet connection to-
gether with the adapter.

To attach the TRA-30 to an adapter, push the transducer


firmly onto the adapter and twist it clockwise.

Twist counter clockwise to unfasten the transducer.

Technical data
Measuring range Max. 100 dBsv
Design Sealed
Temperature range -30° to +70° C
Material, spanner Blacknited steel
Handle cover Urethan
Coaxial cable PVC, length 1.5 m
Connector TNC
Weight 250 g

Part numbers
TRA-30 Transducer with quick connector, incl. cable
CAB-30 Cable for TRA-30

SPM Instrument AB• Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-7. TD-12.B
Transducer with quick connector TRA-31

TRA-31

TRA-31 is a shock pulse transducer with quick connector,


specially designed for narrow spaces.

On TRA-31, the cable is fitted with an angle connector,


making this transducer about 30 mm shorter than the stand-
ard model TRA-30. In all other respects, the two models are
identical.

To attach the TRA-31 to an adapter, push the transducer


firmly onto the adapter and twist it clockwise.

Twist counter clockwise to unfasten the transducer.

Technical data
Measuring range Max. 100 dBsv
Design Sealed
Temperature range -30° to +70° C
Material, spanner Blacknited steel
Material, handle Stainless steel
Coaxial cable PVC, length 1.5 m
Connectors TNC
Length 70 mm
Weight 220 g

Part numbers
TRA-31 Transducer with quick connector incl. cable
46012-1.5 Cable for TRA-31

SPM Instrument AB• Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-7. TD-14.B
Transducer with quick connector and TMU

TRA-32

66
ø 28

TRA-32 is a shock pulse transducer with quick connector,


specially designed for applications where the measuring
cable is longer than 4 m.

TRA-32 has a built-in transducer matching unit (TMU) which


allows a cable length of up to 100 m between the trans-
ducer and the shock pulse meter. TRA-32 fits all SPM adapt-
ers.

If transducer and measuring cable are used in moist envi-


ronments, it is necessary to equip the cable with a sealing
TNC cable plug SPM 13008.

To attach the TRA-32 to an adapter, push the transducer


firmly onto the adapter and twist it clockwise.

Twist counter clockwise to unfasten the transducer.

Technical data
Measuring range Max. 100 dBsv
Design Sealed
Temperature range -30° to +100° C
Material, spanner Blacknited steel
Material, handle Stainless steel
Connector TNC
Max. cable length 100 m

SPM Instrument AB• Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-61.B
Tachometer Probe TAD-18

TAD-12
TAD-13
TAD-18 TAD-11 TAD-17 TAD-15

TAD-14
CAB-10 TAD-16 TAD-10

The Tachometer Probe TAD-18 is used together with Shock


Pulse Tester T2000/T2001 and Shock Pulse Analyzer A2010/
A2011 for optical measurement of the rate of rotation and
for contact measurement of as well the rate of rotation as
the peripheral speed.

Optical measurement of the rate of rotation


A light beam is directed against a reflecting tape on the Max. 45°
rotating object, from a distance of max. 0.6 m and from an
angle of max. 45°.

Contact measurement of rpm


The contact adapter TAD-10 with a rubber tipped contact
center, TAD-11/15, is screwed onto the tachometer probe
and then held against the center of a shaft end or a wheel.

Contact measurement of peripheral speed


The contact adapter TAD-10 with contact wheel is held
against the circumference of a shaft, a belt, etc. The speed
is read out in units, depending on which contact wheel is
used:
Meters per minute – use TAD-12, divide result by 10
Yards per minute – use TAD-13, divide result by 10
Feet per minute – use TAD-17, divide result by 2.

Ordering numbers
TAD-18 Tachometer probe with cable
CAB-10 Spiral cable
TAD-10 Contact adapter TAD-12 = 0.1 m / min.
TAD-13 = 0.1 yd. / min.
TAD-11 Contact center, rpm, short
TAD-17 = 0.5 ft / min.
TAD-15 Contact center, rpm, long
TAD-12 Contact wheel, meter/min.
TAD-13 Contact wheel, yards/min.
TAD-17 Contact wheel, feet/min. Technical specifications
TAD-14 Reflecting tape, pad of 5 sheets Measuring range: max. 20 000 rpm optical
TAD-16 Reflecting tape for thin shafts, 5 sheets Measuring distance: max. 0.6 m (2 ft.)
Dimensions, TAD-18: 171 x 42 mm

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-7. TD-38.B
Temperature probe TEM-11

TEM-11

TEN-10 TEN-11

CAB-10

The temperature probe TEM-11 is used together with SPM's


hand-held instruments Analyzer A30 and Tester T30, for
temperature measurements in the range of –50 to +440 °C.

The probe TEM-11 is connected via the spiral cable CAB-10


to the EXT connector of the instrument. The TEMP menu
appears automatically on the instrument when the tempera-
ture probe is connected. It is power supplied by the instru-
ment.
Two probe tips belong to TEM-11:
• TEN-10 for measuring the surface temperature of
solids
• TEN-11 for measuring the temperatures of liquids.

The probe tips fit into the socket at the front end of the
probe. Probe and tips should be handled and stored with
care. Keep the protective cap on the TEN-10 when the tip is Technical specifications
not being used. Measuring range: –50 to +440 °C
(–58 to +824 °F)
Ordering numbers Maximum offset: ±5 °C (±9 °F)
TEM-11 Temperature probe with cable Measuring uncertainty ± 1° C
CAB-10 Spiral cable Sensitivity 10 mV / °C
TEN-10 Probe tip for solids Output range 0 to 5 V DC
TEN-11 Probe tip for liquids. Power supply +5 V DC
Measuring time: approx. 1 minute
Dimensions,
TEM-11: 118 x ø 42 mm
TEN-10: length 122 mm with cap
TEN-11: length 159 mm
Weight TEM-11: 94 g

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-10. TD-139.B
Countersinking tools for adapters and transducers

ø8
ø 10
ø 6.8

81027 82053
81027

c
ø 6.8 81057

dc
ø 20

p p

b d
min.2, max.4

min.13
min.15

min.1

Combination tools b (mm) p c dc (mm) d


The listed tools are used for correct countersinking of mount-
5.5 81030 81028 ø12 M6 / UNF 1/4"
ing holes for adapters and standard shock pulse transduc-
ers. The combination tool consists of a holder, a replaceable 6.9 81031 81028 ø12 M8
countersink and replaceable pilots. Ordering numbers are 6.6 81032 81028 ø12 UNC 5/16"
shown beside. 8.6 81033 81028 ø12 M10
8.1 81034 81028 ø12 UNC 3/8"
81057 Counterbore 10.3 81035 81029 ø15 M12
The counterbore is used for flat face milling of mounting 10.9 81036 81029 ø15 UNC 1/2"
holes for shock pulse transducers in bolt design and vibra-
tion transducers. The counterbore is mounted in holder
81027 together with a pilot according to the table beside.
ø6
82053 Countersink with fixed pilot
The countersink is intended for mounting hole M8. 81274

Counterbore for Glue-on Transducer 40010


81275
14042 Counterbore, complete ø 2.7
81274 Holder for counterbore
ø 15
81275 Counterbore, diameter 15 mm
14041 Pilot, diameter 2.7 mm 81276
min. 4.5

max. 1

Tools for measuring point preparation


BEX-20 center drill and BEX-21 ball shaped rotary file are
used to prepare measuring points for the probe transducer,
and to faciliate drilling of mounting holes for adapters,
studs, and transducers at an angle.
BEX-20 BEX-21

ø4 ø 15
5

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1999-12. TD-21.B
4
Accessories for Remote Monitoring

71700 B © SPM Instrument AB. ISO 9001 certified.


Transducer Matching Unit TMU-12

20
2 x M4

42
75 34

Transducer Matching Unit TMU-12 is an impedance con-


verter for all permanently installed SPM bearing monitoring TMU-12 Cable length
Min. 60 mm
systems. It is placed between the shock pulse transducer max. 100 m
and the measuring device or measuring terminal. The bracket
on the TMU is fastened with two mounting screws to the
machine or machine foundation. The round connector base
faces towards the transducer.
Measuring Unit BMS-20
In a BMS Measuring Unit, a TMU is always part of the Bearing damage detector
measuring channel. In other SPM systems, it is used to Measuring terminal
extend the length of the coaxial cable between transducer Cable length
and measuring device from max. 4 m to max. 100 m. The max. 4 m
distance between the TMU and the transducer is always
max. 4 m.
Shock pulse transducer
TMU-12 is suitable for both chemically basic and acid envi-
ronments. For installations in moist environments, it is nec-
essary to use sealing TNC cable plugs SPM 13008 to pre-
vent cable corrosion.

TMU-12 Cable length


Min. 65 mm
max. 100 m
Technical data
Casing Stainless steel SS 2382,
AISI 316, and fluor rubber
Sealing IP 65 with TNC connector
IP 67 with connector SPM 13008
Measuring Unit BMS-20
Temperature range – 30° to +100° C Sealing ring
Bearing damage detector
Dimensions 75 x ø 34 mm Measuring terminal
Weight 140 grams
Connectors TNC jacks Moisture proof
Cable length Max. 100 m cable connection with
TNC plug SPM 13008
Fastening screws 2 x M4, stainless steel AISI 316

Shock pulse transducer

SPM Instrument AB• Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-55.B
Terminal cabinet 14318

Key lock BNC connector


150 240 93090

180
121

Open cabinet

Sealed cable inlets, cut to


insert cable. Then crimp
on the connector.
181
4 x M6

The terminal cabinet 14318 can recieve up to 16 coaxial


cables from shock pulse and vibration transducers. Read-
ings are taken using a coaxial cable with a BNC connector.
BNC terminal connectors SPM 93090 are crimped on to the BNC connector
transducer cables. They are ordered separately. 93090

Technical data
Dimensions 240 x 180 x 150 mm
Mounting holes M6, spacing 181 x 121
Casing Stainless steel, SS142333 Ordering numbers
Door lock Removable key
14318 Terminal cabinet
Protection class IP 66
93090 BNC terminal connector, crimp
Temperature range –30° to +80° C

Cable inlets Chloroprene, IP 67


Cable diameter 5 to 7 mm

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2001-04. TD-154.B
Terminal cabinet MTU-16

280

216
164
ø6x4

130 254

The terminal cabinet MTU-16 is equipped with 16 measur-


ing terminals for shock pulse monitoring. Readings are taken
using an adapter SPM 12818, mounted on a coaxial cable
with a TNC connector. The adapter is attached by pushing
it onto the terminal.

Coaxial cables from the transducers are fitted with connec-


tor set SPM 12775. Each cable is held by two screws. TNC

Technical data SPM 12818


Dimensions 280 x 216 x 130 mm
Design Polycarbonate, IP 65
Temperature range –30° to +80° C

Cable inlets Chloroprene, IP 67 Ordering numbers


Cable diameter 5 to 7 mm MTU-16 Terminal cabinet
12818 Adapter
12775 Connector set

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-60.B
Accessories for Remote Monitoring

10393
13778
12112

10392 10396

The terminal bracket SPM 13778 is supplied with holes for


10393 max. 44 mm
12 sealed terminal connectors 13777 (TNC-TNC) or 13781 13008 12112 max. 19 mm
(TNC-BNC) alternatively crimp connectors SPM 93090 (BNC)
or 93113 (TNC). The bracket is made of PVC and can easily
be divided into desired number of holes.

ø32
The parts SPM 10393 and 12112 are bulkhead unions (meas-
uring terminals) for thicker walls or partitions (max 25 mm 10393/12112
10396
and 50 mm respectively). They have TNC jacks on both
sides and are supplied with sealing ring and a dust cap.

10392
The sealing sleeves are used to attach a flexible protection
tube (32 mm inner dia.). The sleeves can only be used
together with standard transducers and bulkheads unions

ø32
SPM 10393 and 12112. 40000
40100

Technical Data
Terminal bracket 13778
Material: PVC
Dimensions: 310 x 25 x 25 x 3 mm
Temp. range: -20° to +70° C

Bulkhead union 10393 and 12112


Material: Nickel plated brass

Sealing sleeve 10392 for transducer


Material: Brass/Reinforced teflon

Sealing sleeve 10396 for bulkhead union


Material: Brass/Nitrile

Part Numbers
M4x8(10), M3x8(10)
13778 Terminal bracket
10393 Bulkhead union, max. wall thickness 50 mm RXS-H 2.9x6
12112 Bulkhead union, max. wall thickness 25 mm
10392 Sealing sleeve for transducer
10396 Sealing sleeve for bulkhead union

16 9

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-7. TD-23.B
Terminal Connectors

SPM 13777 SPM 13781

The terminal connectors SPM 13777 (TNC-TNC) and 13781


(TNC-BNC) are mainly used as measuring terminals, con-
necting a hand-held shock pulse meter with a permanently
installed shock pulse transducer. They are then normally
mounted on the terminal bracket SPM 13778.

The terminal connectors can also be used as bulkhead un-


ions for walls with a thickness of up to 4.5 mm. A sealed
connection is achieved by using SPM 13008 as TNC cable

ø 14 mm
connector.

The open end of the connectors should always be pro-


tected by dust caps, SPM 93035 for TNC and SPM 93061
for BNC.

Technical data
max. 4,5 mm
Total length 35 mm
Thread TNC
Nut width 17 mm
Mounting hole ø14 mm
Max wall thickness 4.5 mm
Material, connector body SS 2382
Material, nuts Nickel plated brass

Ordering numbers
13777 Terminal connector, TNC-TNC
13781 Terminal connector, TNC-BNC

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-81.B
5
Cables, Connectors, and Tools

71700 B © SPM Instrument AB. ISO 9001 certified.


Measuring cables

46041-L
45011-L 46057-L
45300-L 46012-L 46045-L
46044-L 46059-L 46058-L

10473 81018 82166

Cables for shock pulse transducers and vibra- Cables for vibration transducers without
tion transducers with pre-amplifier pre-amplifier
45011-L Cable with connectors, -10 to 70 °C 46044-L Low noise cable with connectors,
46012-L Cable with connectors, -10 to 70 °C -10 to 70 °C, L = max. 10 m
46058-L Cable with connectors, -10 to 70 °C 46045-L Low noise coaxial cable with one standard
45300-L Cable with connectors, -40 to 125 C TNC and one sealing connector (SPM 13008),
46041-L Cable with connectors, -40 to 125 °C -10 to 70 °C, L = max. 10 m
46057-L Cable with connectors, -40 to 125 °C 46059-L Low noise cable with connectors,
90005-L Coaxial cable without connctors, -10to 70 °C -10 to 70 °C, L = max. 10 m
90267-L Coaxial cable without connctors, -40 to 125 °C 90176-L Low noise coaxial cable without connectors,
-10 to 70 °C
Accessories 90292-L Low noise coaxial cable without connectors,
10473 Sealing cover for TNC/BNC connector -30 to 150 °C
81018 PVC sleeve for TNC/BNC crimp connector
82166 Neoprene tube for cable 90267-L Cable for vibration transducer TRV-01
46019-L Low noise cable with connectors,
Single conductor cables -10 to 70 °C, L = max. 10 m
90031-L Single conductor cable, -40 to 80 °C
90025-L Single conductor cable, -40 to 150 °C
93048 1/4" tab terminal for single conductor cable

Note:
When ordering cables, please state the desired
length (L) in meters.

SPM Instrument AB • Box 504 • S-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2002-04. TD-018.B
Connectors

13777 13781 93022, 93121 93031, 93156 93032 93033

93035 93047 93060 93061 93062

93067 93077, 93129 93090 93091 93103, 93120

93105 93113 93119 13008 13268 13443

The listed equipment is used for SPM coaxial cable installations for shock pulse and vibration monitoring. See SPM
installation instructions and application descriptions for details.

TNC - connections BNC connections


13777 Terminal connector, TNC/TNC 93060 BNC cable connector, plug crimp
13781 Terminal connector, TNC/BNC 93061 BNC dust cap
93022 TNC cable connector, plug, crimp 93062 BNC-TNC adapter, plug-jack
93031 TNC cable connector, plug, screw-type 93090 BNC terminal connector, crimp
93032 TNC angle adapter, plug-jack 93105 BNC angle connector, crimp
93033 TNC adapter, jack-jack 93119 Terminal connector, flange, BNC-crimp
93047 TNC cable connector, jack, crimp
93067 TNC-BNC adapter, plug-jack SMA connections
93077 TNC angle connector, crimp 93103 SMA cable connector, plug, crimp
93091 Terminal connector, flange, TNC-crimp 93120 SMA cable connector, crimp, for cable 90146
93113 TNC terminal connector, crimp
93121 TNC cable connector, crimp, for cable 90146 SMB connections
93129 TNC angle connector, solder/crimp, for 93286 SMB cable connector, crimp
cable 90146
93149 Contact pin, TNC/BNC for cable 90176 Waterproof connections
93156 TNC cable connector, screw-type with strain 13008 TNC cable connector, plug, crimp
relief, solder/screw type 13268 TNC adapter, jack-jack, for sealed connection
13443 Sealing plug for connector 13008
93035 TNC dust cap for jack

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2001-01. TD-019.B
TNC Cable Plug for Sealed Installation

SPM 13008

SPM 13008 is a special TNC cable plug for SPM installations


in moist environments. It prevents moisture from entering
the coaxial cable and causing loss of signal strength. The
cable plug fits standard shock pulse transducers and other
SPM measuring equipment with TNC jacks having a ø 14
mm connector base. It must be used wherever the TNC SPM 13008
SPM
connection is exposed to water, steam, or high humidity.
93022
The cable seal, marked A below, seals the cable entry when
the connector collet is tightened. The sealing ring marked B
is placed over the receiving TNC jack and seals the other
end of the connection.
Moist environment Normal environment
Note: The connector package contains two cable seals (A)
of different sizes, marked in different colours:

• green seal for cable diameter 4 mm


• black seal for cable diameter 5 mm.

Use the appropriate seal and discard the other. Lubricate


the thread with oil or grease. Tighten the connector with a
14 mm open wrench.

The instruction for cable stripping is included in the pack-


age. SPM offers two tools for connector mounting:

81052 Cutting tool for stripping coaxial cables


81026 Crimping tool for fitting cable connectors.

To join two cables in moist environment, use the TNC adapter


SPM 13268 (separate data sheet) together with two cable
connectors SPM 13008.

Technical data:
Material, connector body: Stainless steel, SS 2382
Connector type: TNC plug
Seals: Viton (fluor rubber)

SPM Instrument AB• Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-7. TD-09.B
TNC Adapter for Sealed Installation

SPM 13268

SPM 13268 is a special TNC adapter (jack - jack) for joining


two coaxial cables. It is used to repair broken cables or to
prolong cables during installation. Sealing
rings
In environments where the connection is exposed to water, SPM 13008 SPM 13008
steam, or high humidity, the cable plugs must be of type
SPM 13008. This type of plug prevents moisture from enter-
ing the coaxial cable and causing loss of signal strength.
The sealing rings are placed over the receiving TNC jacks of
the adapter. The connection is tightened with two 14 mm
open wrenches until the sealing rings are slightly flattened
against the adapter body. Cable joint in moist environmemt

Technical Data
Material, adapter body: Stainless steel, SS 2382
Connector type: TNC jack

SPM Instrument AB• Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-7. TD-25.B
Tools for fitting cables and connectors

81026 81052 81130

81127

81051 81300

The listed tools are used to prepare coaxial cables and to 81026 Crimping tool for fitting TNC/BNC connectors
mount connectors for SPM installations, both for shock
pulse and vibration monitoring. 81051 Crimping tool for fitting tab terminals

Crimping tool SPM 81026 and SPM 81300 are used for 81052 Cutting tool for coaxial cables
coaxial cables, SPM 81051 for single conductor cables.
81127 Fitting tool for connectors with strain relief

81130 Expansion pliers for fitting neoprene tube


SPM 82166

81300 Crimping tool for fitting SMB connectors

SPM Instrument AB • Box 4 • SE-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2001-01. TD-20.B
6
Vibration Monitoring Instruments

71700 B © SPM Instrument AB. ISO 9001 certified.


Vibrameter VIB-10 / VIB-11

VIB-10B
VIB-11B TRV-22
TRV-23

46044
46045

TRX-16

TRX-17 VIC-11 / 12 VIC-13

Vibrameter VIB-10 (VIB-11) has been designed as a simple The evaluation of machine condition is based on a single
diagnostic tool for preventive maintenance. The instrument parameter, vibration severity. This means that the instru-
and the monitoring technique are based on the recommen- ment needs to display only one measured value, which
dations of ISO and the equivalent national standard organi- reduces its cost and makes it easy to handle.
zations BS, VDI, etc.
The standards also provide a set of norm values for the
These standards make the assumption that limited informa- common types of industrial plant. The readings obtained on
tion, obtained easily and at a low cost, is often as useful as a a particular machine are interpreted by comparing them
detailed analysis at the price of expensive equipment and with the norm values for similar machines.
elaborate techniques. They state that it is possible to de-
tect even minor changes in the operating condition of a
machine by measuring its general vibration level. It is as-
sumed that, once the change has been noted, a competent
inspector or repair crew will be able to find the actual
defects which caused it.

Part Numbers Technical data


VIB-10B Vibrameter mm/s, incl. battery cells Measuring range VIB-10B: 0.5 to 99.9 mm/s RMS,
VIB-11B Vibrameter in/s, incl.battery cells VIB-11B: 0.01 to 3.93 in/s RMS,
TRV-22 Vibration transducer, M8 10 to 1000 Hz
TRV-23 Vibration transducer, UNF 1/4"-28 Resolution: 0.1 mm/s (0.01 in/s)
TRX-16 Magnetic base for transducer TRV-22 Accuracy 2% ± 0.2 mm/s (2% ± 0.02 in/s)
TRX-17 Probe for transducer TRV-22 Power supply Four 1.5 V alkaline cells
46044 Measuring cable with connectors, 1.5 m (e.g. MN 1500 or UCAR E91)
46045 Measuring cable with sealing TNC plug, 1.5 m Temp. range 0 to +55 °C (32 to 131 °F)
VIC-11 Follow-up forms mm/s (VIB-10), pad of 25 Display 3 digits, red LED
VIC-12 Follow-up forms in/s (VIB-11), pad of 25 Switch-off Automatic
VIC-13 Follow-up forms, balancing, pad of 25 Protective cover Polyurethane
90022 Battery Dimensions 210 x 75 x 30 mm
(8.3" x 2.9" x 1.2")
Weight 410 grams (14 oz) incl. batteries
Connector type TNC

SPM Instrument AB • Box 4 • SE-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2001-05. TD-30.B
Vibration Transducer TRV-18 / 19

Measuring direction

17

ø 27.5
Cable

36
clamp

9
t TRV-18: t = M8
TRV-19: t = UNF 1/4"- 28
ø 15

The transducers TRV-18 and TRV-19 are piezo-electric ac-


celerometers of compression type with built-in preamplifier,
Moist environment:
designed for vibration monitoring of industrial machinery. SPM 13008
They are used in permanent installations with the CMM
System (condition monitoring modules VMM). The cable
Electric
length between transducer and measuring unit is max. insulation:
50m (165 ft). TRX-18

The transducer is mounted against a smooth, flat surface


on the machine. TRV-18 has thread size M8 and TRV-19 has
UNF 1/4"-28. The transducers are delivered with three
washers for adjusting the connector angle. Each washer
turns the transducer 90°. The coaxial cable (SPM 90005-L
or 90267-L) with TNC connector must be secured with a
clamp close to the transducer.

In moist environments, use sealing TNC cable plugs SPM


13008 to prevent cable corrosion. For electric insulation,
use insulation foot TRX-18 (TRV-18) or TRX-19 (TRV-19). ø 6.9 min. 16 M8
(ø 5.5) (UNF
1/4"-28)
Technical data
min. 10
min. 12

Nominal sensitivity, main axis: 1.2 mV/m/s2 *


max. 0.7

Transverse sensitivity: max. 10%


Typical base strain sensitivity: 0.01 m/s2/µ strain
Linear frequency range: 3 to 1000 Hz
Max. peak acceleration: 600 m/s2
Temperature range: -20° C to +70° C
(-4° F to +158° F) Mounting tools
Typical temperature drift: 0.25% / °C 81027 Holder for counterbore
Casing: Stainless steel, acid proof, 81057 Counterbore, diameter 20 mm
AISI 316 (SS 2382) 81030 Pilot for UNF 1/4" (TRV-19)
Design: Sealed 81031 Pilot for M8 (TRV-18)
Weight: 135 grams (5 oz)
To drill the mounting hole, use drill bit 6.9 mm for M8 and
Connector type: TNC
5.5 mm for UNF 1/4". Torque and unscrew the transducer
Torque limit: 10 Nm (7.4 lbf · ft)
with a torque wrench and a 17 mm socket (SPM 81086).
* Individual value given on the calibration chart.

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 26440 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-109.B
Vibration Transducer TRV-20/21

Measuring direction

17

ø 27.5
Cable

36
clamp

9
t
ø15

The transducers TRV-20 and TRV-21 are piezo-electric


accelerometers of compression type with built-in pre- Moist environment:
amplifier, designed for vibration monitoring of industrial SPM 13008
Electric
machinery. The transducers are used in permanent in-
insulation:
stallations with the CMS System (measuring unit VCM). The TRX-18 (M8)
cable length between transducer and measuring unit is TRX-19 (UNF)
max. 50 m (165 ft).

The transducer is mounted against a smooth, flat surface on


the machine. TRV-20 has thread size M8 and TRV-21 has
UNF 1/4"-28. The transducers are delivered with three wash-
ers for adjusting the connector angle. Each washer turns the
transducer 90°. The coaxial cable (SPM 90005-L or 90267-L) Typical frequency response
with TNC connector must be secured with a clamp close to
the transducer.

In moist environments, use sealing TNC cable plugs SPM


13008 to prevent cable corrosion. For electric insulation,
use insulated installation foot TRX-18/19.
Typical thermal response

Technical data
Nominal sensitivity, main axis: 4.0 mV/m/s2 *
Transverse sensitivity: max. 10%
Typical base strain sensitivity: 0.01 m/s2/m strain
Linear frequency range: 2 to 5000 Hz
ø 6.9 min. 16 M8
Max. peak acceleration: 600 m/s2 (ø 5.5) (UNF
Temperature range: -20° C to +125° C 1/2"-28)

(-4° F to +260° F)
min. 10
min. 12

max. 0.7

Power requirements: 12–24 V, 2–5 mA


Casing: Stainless steel, acid proof,
AISI 316 (SS 2382)
Design: Sealed Mounting tools
Weight: 135 grams (5 oz) 81027 Holder for counterbore
Connector type: TNC 81057 Counterbore, diameter 20 mm
Torque limit: 10 Nm (7.4 lbf · ft) 81030 Pilot for UNF 1/4" (TRV-21)
81031 Pilot for M8 (TRV-20)
* Individual value given on the calibration chart.
To drill the mounting hole, use drill bit 6.9 mm for M8 and
5.5 mm for UNF 1/4". Torque and unscrew the transducer
with a torque wrench and a 17 mm socket (SPM 81086).

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-12. TD-124.B
Vibration Transducer TRV-22 / 23

Measuring direction
17

ø 27.5

Cable

36
clamp

9
t TRV-22: t = M8
ø 15 TRV-23: t = UNF 1/4"- 28

The transducers TRV-22 and TRV-23 are piezo-electric ac-


celerometers of compression type, designed for vibration
monitoring of industrial machinery. They can be used to- SPM 13008
gether with handheld instruments or in permanent installa-
tions. Max. cable length between transducer and measuring
unit is 10 m (33 ft).
The transducer is mounted in a threaded hole on a smooth,
flat surface on the machine. It is delivered with three wash-
ers for adjusting the connector angle. Each washer turns the
transducer 90°. Fix low noise coaxial cable (SPM 90176-L or
90292-L) with TNC connector with a clamp close to the
transducer.
For installations in moist environments, use sealing TNC Installation in moist environments
cable plugs SPM 13008 to prevent cable corrosion.

Technical data
Nominal sensitivity, main axis: 10 pC/m/s2 ± 20% *
Transverse sensitivity: max. 10%
Typical base strain sensitivity: 0.01 m/s2/m strain
Linear frequency range: 0 to 5000 Hz
Max. peak acceleration: 600 m/s2 ø 6.9 min. 16 M8
Temperature range: –30° C to +150° C (ø 5.5) (UNF
(–22° F to +302° F) 1/4"-28)
Typical temperature drift: 0.25% / °C
min. 10
min. 12

Casing: Stainless, acid proof steel,


max. 0.7

SS 2382/AISI 316
Design: Sealed
Weight: 145 grams (5 oz)
Connector type: TNC
Torque limit: 10 Nm (7.4 lbf/ ft)

* Individual value given on the calibration chart. To drill the mounting hole, use drill bit 6.9 mm (M8) or 5.5
mm (UNF 1/4"-28). Torque and unscrew the transducer with
Part Numbers a torque wrench and a 17 mm socket (SPM 81086).
TRV-22 Vibration transducer, M 8
TRV-23 Vibration transducer, UNF 1/4"-28
13008 Sealing TNC cable plug
81027 Holder for counterbore
81057 Counterbore, diam. 20 mm
81030 Pilot for UNF 1/4" (TRV-23)
81031 Pilot for M8 (TRV-22)

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1999-10. TD-133.B
7
Diagnostic Tools for Maintenance

71700 B © SPM Instrument AB. ISO 9001 certified.


Electronic Stethoscope ELS-12

ELS-12

ELT-10

EAR-10

Battery powered monitoring instrument for a large number Noise sources are located with the probe tip (length 60 or
of applications. ELS-12 is a sensitive electronic listening 290 mm). The sound is fed via an amplifier with volume
device for all kinds of mechanical noise within machinery: control to the headset. Ear defenders shut out background
valve chatter, piston slap, gear and pump noise, electric noise.
relay operation, etc.

Part Numbers Technical Data


ELS-12 Electronic Stethoscope Casing: Splash proof ABS plastic
ELT-10 Probes, 60 and 290 mm Nominal battery voltage: 9 V

EAR-10 Earphone incl. spiral cable Temperature range: 0° to + 55° C


Weight: 300 g incl. battery and probe
90109 Battery, 9 V, type IEC6LG22
Dimensions: 205 x 50 x 40 mm

SPM Instrument AB • Box 504 • S-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2002-04. TD-28.B
Tachometer TAC-10

TAD-15

TAC-10

TAD-10 TAD-11

TAD-12

TAD-14 / 16
TAD-13

TAC-10 is a digital tachometer with three measuring func- The instrument has a four digit display (red LED), an optical
tions: non-contact measurement of rotational speed and range of up to 600 mm, a 50 second memory, and auto-
contact measurement of both rotational speed and periph- matic switch-off.
eral velocity.
TAC-10 is designed for duty in rough industrial environ-
ments. The oil resistant rubber sleeve gives extra shock
protection.

Part Numbers Technical Data


TAC-10 Tachometer Display Four digits, red LED
TAD-10 Contact adapter Switch-off Automatic
TAD-11 Contact center Memory Last reading is held for
TAD-12 Contact wheel (m) appr. 50 seconds
TAD-13 Contact wheel (yard) Power supply Four 1.5 V alkaline cells,
TAD-14 Reflecting tape (5 sheets) (e.g. MN 1500)
TAD-15 Contact center, long On Target Indicator Light dot in display window
TAD-16 Reflecting tape for thin shafts (5 sheets) Speed range 50 – 19 999 r.p.m.
90022 Battery 5 – 1 999 m/min.
Resolution ± 1 of reading, optical
Sample time 1 second
Temp. range 0 - 55° C
Angle of Up to 45° from rotational
Operation plane of reflective marker
Optical range 10 - 600 mm
Dimensions 195 x 75 x 30 mm
Weight 400 g incl. batteries

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-7. TD-27.B
Motor Checker EMC-11

EMC-11 EMD-11

The EMC-11 provides a comprehensive check of rotor and No dismantling of the motor is needed, just isolate the
stator inductance, resistance and insulation. The instrument power supply before measuring. Built in a carrying case, the
tests three phase squirrel-cage motors, submersible pumps, Motor Checker EMC-11 is supplied complete with test leads.
power tools etc.

Part Numbers Technical Data


EMC-11 Motor Checker, complete Measuring range
EMD-11 Test leads with contact clips, pair Inductance: 1 - 300 mH in 11 steps
90109 Battery Resistance: 0.2 - 60 Ω in 11 steps
Insulation: 0.2 - 40 MΩ at 1 000 Vdc,
max. 0.25 mA
Temperature range: 0 to +55 °C
Batteries: 2 x 9 V, IEC 6LF22
Size: 190 x 135 x 75 mm
Weight: 1 kg

SPM Instrument AB • Box 4 • SE-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2001-01. TD-32.B
Leak Detector LDE-10

LDF-10 EAR-10

LDE-10

LDF-11

LDF-12 LDF-13
ELT-10

LDE-10 is an excellent instrument for locating leaks in any Tightness control in non-pressurized compartments such as
pressure and vacuum system by detecting ultrasound gen- containers, tanks, cars, etc. with the LDE-10 requires the
erated by a gas or liquid when flowing through a small use of the ultrasonic transmitter LDF-13.
restrictive opening.
The transmitter LDF-13 is placed inside the compartment
The ultrasound is indicated by an LED-array and an audible under investigation and switched on to emit an ultrasonic
tone through the earphone headset. As the instrument is signal. This signal will pass through any orifice or faulty seal
moved closer to the ultrasonic source more LED´s will light and will be quickly located by the LDE-10.
up. Simultaneously, the frequency of the tone rises.

Part Numbers Technical Data


LDE-10 Leak detector Leak Detector LDE-10
LDF-10 Ultrasonic microphone Visual indicator: LED-array
Audible indicator: VCO 0 - 5 kHz
LDF-11 Extension tube Sensitivity: Adjustable 50 dB
LDF-12 Ultrasonic probe Min. detectable
sound pressure: 1 nbar at 40 kHz
ELT-10 Probe tips, 60 and 290 mm
Casing: ABS moulding
LDF-13 Ultrasonic transmitter Temperature range: 0 to +55 °C
Battery: 9 V, IEC type 6LF22
EAR-10 Earphone, incl. cable
Dimensions: 215 x 50 x 40 mm
90109 Battery Weight: 240 g

Ultrasonic Transmitter LDF-13


Frequency: 40 kHz
Casing: ABS plastic
Battery: 9 V, type 6LF22
Temperature range: -30 to +55 °C
Dimensions: 100 x 50 x 20 mm
Weight: 100 g

SPM Instrument AB • Box 504 • S-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2002-04. TD-29.B
Lubchecker®

81262

13645
TRA-33

13803

TRA-40

13804 CAB-33

LUBCHECKER® is an instrument designed for use when Data and Performances


greasing rolling bearings to verify that the lubricant actually Dimensions: 142 x 65 x 25 mm (5.6"x2.6"x1")
reaches the bearing. Weight, instrument: 250 g (7.1 oz)
Measuring principle: Shock Pulse Method
LUBCHECKER uses the SPM measuring technique -"the
Indication: Bar-graph display, 10 steps
Shock Pulse Method". This means that the instrument uti-
Battery: 9 V, type IEC 6LF22
lises the information from the shock pulses generated in a
Casing: ABS-plastics, IP 54
rotating bearing to assess the effectiveness of lubrication.
Temperature range: 0° to 50° C (32° to 120° F)
The instrument is part of the measuring system for the SPM Connection: BNC
method and is based on know-how and experience from
evaluations made with analysis instruments at SPM Instru- Ordering Numbers
ment AB. LUB -10 LUBCHECKER standard set:

LUBCHECKER requires a well defined measuring point on 1 off 13645 LUBCHECKER instrument
the bearing housing. with bracket 13803
1 off TRA-33 Shock pulse transducer with
Operating the Instrument quick fit, incl. cable
Connect the transducer. The transducer TRA-40 is attached 1 off 81262 Strap
to the measuring point of the bearing to be lubricated while 10 off 36010 Glue-on adapters
the quick fit transducer TRA-33 is connected to the adapter
LUB -11 LUBCHECKER standard set:
of the bearing housing. Push and twist it clockwise until it
stops. 1 off 13645 LUBCHECKER instrument
with bracket 13803
Press and release the instrument start button. The leftmost 1 off TRA-40 Transducer with magnet
LED on the bar-graph display should illuminate. incl. cable
After initialising (approx. 2 seconds), all LEDs should illu- 1 off 81262 Strap
minate. The instrument is now registering the SPM signal
level corresponding to current lubrication conditions.
Accessories
13804 Magnet fitting
Flashing of the left or right LED indicates that the measured
signal is out-of- range, low or high respectively. Spare Parts
Connect the grease gun to the nipple and pump grease into 13803 Bracket
the bearing. Pump till the first LEDs go out. Now pump in 81262 Strap
the specified quantity. The LEDs progressively go out as CAB-33 Cable for transducer
grease reaches the load zone of the bearing. Further injec- TRA-33 Shock pulse transducer, quick
tion of grease does not result in more LEDs going out. fit, with cable
TRA-40 Transducer with magnet, cable

SPM Instrument AB• Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-82.B
8
Machine Alignment System and Shims

71700 B © SPM Instrument AB. ISO 9001 certified.


Alignment Calculator MAC-10

MAC-10 EMS-10 CAS-20

Alignment Calculator MAC-10 utilizes the reverse indicator


method, the simplest and most accurate alignment method
without having to break the coupling. An electronic indica-
tor transmits the run-out measurements to the instrument
display: vertical and horizontal offset, vertical and horizon-
tal angularity and required corrections of the machine posi-
tion, both front and back, in horizontal and vertical direc-
tion.

A complete indicator mounting kit is part of the alignment


system. The set accommodates shaft diameters between 15
and 120 mm and coupling widths up to 265 mm. Accesso-
ries for shaft diameters up to 400 mm and coupling widths
up to 465 mm are available, as well as a comprehensive
range of ready-made shims in various sizes.
MAA-14

Technical data Part numbers


Measuring range Max. target deflection 15 mm MAC-10 Alignment calculator incl. battery
Resolution 0.01 mm CAS-20 Carrying case for complete set
Power 9 V battery, type 6LR22 EMS-10 Electronic indicator
Temperature 0° C to 50° C MAA-14 Mounting kit with electronic indicator
Weight, calculator 0.3 kg
Size, calculator 145 x 90 x 32 mm
Casing, calculator ABS
Keypad 15 keys, sealed membrane
LCD display Supertwist

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-51.B
Electronic Indicator EMS-10

EMS-10

The Electronic Indicator EMS-10 is a length measuring de- Technical data


vice, range 0 to 15 mm. It is used in connection with the Measuring range: 0 to 15 mm
SPM Alignment Calculator MAC-10, to measure the vertical Resolution: 0.01 mm
and horizontal displacement of shafts. The measuring cable Connecting cable: Length 2.1 m
is permanently attached. Casing: GE "ULTEM"
For shaft alignment, one normally uses two indicators, Weight: 85 g
mounted on the shaft as shown above.

EMS-10 can also be connected to the Alignment Calculator


MAC-5, via a special converter box (EMS-20).

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-89.B
Mounting kits with alignment indicators

MAA-28
MAA-32
MAA-26

MAA-24
MAA-31 MAA-22
EMS-10
MAA-20
MAA-40

MAA-10

MAA-11 MAA-80 / 81 /82 / 83 MAA-56 MAA-57

MAA-42

MAA-44
MAA-70
MAA-30 MAA-60

TOL-21
MAA-61

The mounting kit MAA-14 consists of the following parts: Optional accessories
MAA-10 Top bracket (2) MAA-31 Mounting post, 88 mm
MAA-11 Bottom bracket (2) MAA-60 Rod storage tube with caps
MAA-20 Target support rod, 150 mm (1) CAS-20 Carrying case
MAA-26 Target support rod, 300 mm (1) MAA-56 Indicator clamp, 32 mm
MAA-32 Mounting post, 165 mm (1) MAA-57 Indicator clamp, 44 mm
MAA-40 Rod swivel (4)
MAA-42 Thumb nut (4) Mounting straps:
MAA-44 Threaded rod (4) MAA-80 for shaft ø 120 - 200 mm
MAA-61 Indicator target (1) MAA-81 for shaft ø 200 - 275 mm
MAA-70 Tape measure (1) MAA-82 for shaft ø 275 - 340 mm
EMS-10 Electronic indicator (1) MAA-83 for shaft ø 340 - 400 mm
TOL-21 Torquing tool (1)
4 of each type is needed to fasten the brackets.

Accessory kit MAA-18 for 2:nd indlicator consists of: Target support rods, ø 10 mm:

EMS-10 Electronic indicator (1) MAA-20 Target support rod, 150 mm


MAA-22 Target support rod, 200 mm
MAA-20 Target support rod, 150 mm (1)
MAA-24 Target support rod, 250 mm
MAA-26 Target support rod, 300 mm (1)
MAA-26 Target support rod, 300 mm
MAA-32 Mounting post, 165 mm (1)
MAA-61 Indicator target (1) MAA-28 Target support rod, 350 mm

All items can be ordered separately as spare parts.

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-53.B
Precut shims

B
SHIMCASE

The line of shimming materials contains five different 10 stainless steel shims, single thickness
sizes, fitting almost any type of machine foot. The user Ordering numbers
can choose between solid stainless steel shims and lami- Dimension Thickness (mm)
nated shims in either brass or stainless steel. A B C 0.025 0.05 0.10 0.20 0.25 0.40
35 30 9 S0-005 S0-010 S0-020 S0-025 S0-040
Solid shims in stainless steel 50 50 13 S1-0025 S1-005 S1-010 S1-020 S1-025 S1-040
Solid shims can be provided in a handy box, containing 75 75 21 S2-0025 S2-005 S2-010 S2-020 S2-025 S2-040
10 shims each of 5 different thicknesses, from 0.05 to 1 100 100 32 S3-0025 S3-005 S3-010 S3-020 S3-025 S3-040
mm. They are also available as packs of 10 in single 125 125 45 S4-0025 S4-005 S4-010 S4-020 S4-025 S4-040
thickness, in accordance with ordering number tables. 200 200 55 S5-005 S5-010 S5-020 S5-025 S5-040

Laminated shims 10 stainless steel shims, single thickness


Ordering numbers
Packs of 20 laminated shims are available in either brass
Dimension Thickness (mm)
or stainless steel. Each shim has a thickness of 1.00 mm,
A B C 0.50 0.70 1.00 2.00 3.00
divided into 12 layers. Laminated shims always fit - just
peel off the required thickness. 35 30 9 S0-050 S0-070 S0-100
50 50 13 S1-050 S1-070 S1-100 S1-200 S1-300
Cases with solid shims 75 75 21 S2-050 S2-070 S2-100 S2-200 S2-300
100 100 32 S3-050 S3-070 S3-100 S3-200 S3-300
Solid shims in stainless steel are available packaged in
125 125 45 S4-050 S4-070 S4-100 S4-200 S4-300
convenient aluminium framed cases with a compart-
200 200 55 S5-050 S5-070 S5-100 S5-200 S5-300
mentalised high density foam insert. The refillable cases
are available with four different assortments. The cases 50 stainless steel shims, 10 of each thickness, 0.05 - 1.00 mm
are overall 350 x 160 x 280 mm except for SHIMCASE 4
Dimension Ordering numbers
which is 540 x 210 x 320 mm.
A B C Thickness 0.05, 0.10, 0.25, 0.50 and1.00 mm

Ordering numbers, cases with solid shims 50 50 13 S1-PAK


75 75 21 S2-PAK
SHIMCASE 1 360 shims: 2 x S1-, S2- and S3-PAK + 2 x 100 100 32 S3-PAK
S1-, S2- and S3-200. Weight 13 kg. 125 125 45 S4-PAK
200 200 55 S5-PAK
SHIMCASE 2 510 shims: 2 x S1-, S2- and S3-PAK + 2 x
S1-, S2- and S3-020; 040; 070; 200. Laminated shims, pack of 20, thickness 1.00 mm
Weight 17 kg.
Dimension Ordering numbers Ordering numbers
SHIMCASE 3 340 shims: 2 x S3- and S4-PAK + 2 x S3- A B C Stainless steel Brass
and S4-020; 040; 070; 200. Weight 15 kg. 50 50 13 LS1-PAK LB1-PAK
75 75 21 LS2-PAK LB2-PAK
SHIMCASE 4 720 shims: 2 x S1-, S2-, S3- and S4-PAK +
100 100 32 LS3-PAK LB3-PAK
2 x S1-, S2-, S3- and S4-020; 040; 070;
125 125 45 LS4-PAK LB4-PAK
200. Weight 26 kg.
200 200 55 LS5-PAK LB5-PAK

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-07. TD-54.B
9
Instruments Approved for Potential Explosive Atmosphere

71700 B © SPM Instrument AB. ISO 9001 certified.


Machine Condition Analyzer A30Ex

TAD-22
TRA-34
A30Ex
TAD-23
TAD-24
TAD-25
TAD-20
TAD-21 13980

13882

TRA-35 TEN-10
TEN-11

TRV-26
TRV-27 TEM-11Ex

TRX-16 TRX-17
13881 CAS-14 CAS-15

Part numbers Speed measurement


A30-1Ex Machine Condition Analyzer A30 Basic Ex 13882 Tachometer probe with cable, Ex
A30-2Ex Machine Condition Analyzer A30 Logger Ex TAD-20 Contact adapter
A30-3Ex Machine Condition Analyzer A30 Expert Ex TAD-21 Contact center, rpm, short
13881 Communication module, Ex TAD-22 Contact center, rpm, long
CAB-35 Computer cable, 9 pole female plugs TAD-23 Contact wheel, meter / min.
93162 Cable adapter 9 male/ 25 female TAD-24 Contact wheel, yards / min.
CAS-14 Carrying case TAD-25 Contact wheel, feet / min.
CAS-15 Carrying case with foam insert TAD-14 Reflecting tape, pad of 5 sheets
EMD-13 Carrying strap
TAD-16 Reflecting tape for thin shafts, 5 sheets
FUP-02 Follow-up form for A30Ex, pad of 25 (mm)
FUP-04 Follow-up form for A30Ex, pad of 25 (inch) Temperature measurement
TEM-11Ex Temperature probe incl. cable
Shock pulse measurement (SPM)
TEN-10 Temperature probe tip surface
TRA-34 Shock pulse transducer, probe assembly, Ex
TEN-11 Temperature probe tip liquid
TRA-35 Shock pulse transd. with quick connector, Ex
13980 Earphones, headset with ear defenders, Ex Spare parts
CAB-07 Cable for remote monitoring 1.5 m (5ft) 13915 Probe tip for TRA-34
13108 Sleeve for probe tip (TRA-34)
Vibration measurement
13892 Handle for probe TRA-34
TRV-26 Vibration transducer M8, Ex
CAB-34 Cable for TRA-34
TRV-27 Vibration transducer 1/4" x 28 UNF, Ex
CAB-10 Spiral cable for 13980, 13882, TEM-11Ex
TRX-16 Magnetic foot for vibration transducer
45011-1.5 Cable for TRA-35
TRX-17 Probe for vibration measurement
90022 Battery, 1,5 V, alcaline, AA-cell
VIC-19 Cable for vibration transducer

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1999-12. TD-130.B
Machine Condition Analyzer A30Ex

PC connection
A30-1 A30-2
9 pole
Basic Logger
female plug
CAB-35
A30-3
9 male /
Expert
25 female
13881 93162

CAB-10

A30 Ex is a machine condition analyzer designed for a reliable Shock pulse (SPM® LR/HR)
preventive maintenance of industrial machines. A30 Ex is available Measuring range: –19 to 99 dBsv
in three versions. With ”Basic”, measuring results are recorded
Resolution: 1 dBsv
manually. ”Logger” is a data logger and works together with SPM
software Condmaster®Pro. ”Expert” has all the logger features. In Accuracy: ± 1 dBsv
addition, it uses the EVAM® method for vibration analysis. A
”Basic” version can be upgraded to ”Logger” and ”Expert”. Vibration severity (ISO 10816)
Measuring range: 0.5 to 49.9 mm/s RMS
Measuring techniques Analyzer A30 Ex (0.02 to 2.0 in/s RMS)
and other features Basic Logger Expert Resolution: 0.1 mm/s (0.01 in/s)
Shock pulse, HR/LR • • • Accuracy: ± (0.2 mm/s + 2% of reading)
Vibration severity, ISO 10816 • • • Frequency range: 3 to 1000 Hz
Temperature measurement • • •
Speed, contact and optical • • • Speed measurement
Continuous reading • • • Measuring range: 10 to 19 999 rpm optical
Data logging with Condmaster®Pro • • Measuring distance: max. 0.6 m (2 ft.)
Free value recording • •
Comment recording • • Resolution: 1 rpm
Check point record • • Accuracy: ± (1 rev. + 0.1% of reading)
Continuous recording • •
Vibration spectrum • Temperature measurement
Evaluated vibration analysis • Measuring range: –50 to +440 °C (–58 to 824 °F)
Resolution: 1 °C (1 °F)

Instrument specifications Alternative measuring systems


Intrinsic safety: EEx ib l/llB T4 No. per meas.point: 2
Enclosure: IP43 Additional information: date / time and comments
General features: language selection, battery test,
continuous reading, transducer line
test, automatic idle / power off Long time recording
Temperature range: 0 to +50 °C (32 to 120 °F) Measuring parameters: SPM, VIB, temperature/speed
Power supply: 6 x 1.5 V LR6 alkaline cells Measuring interval: adjustable 0 - 60 minutes
Battery life: power down 1 year, or 5000 typical
measurements, or continuous Vibration analysis (EVAM®)
recording 50 hours Window: Hanning
Size: 255 x105 x 60 mm (10 x 4.2 x 2.4 in) Number of samples: 1024 / 2048
FFT result: 400 / 800 spectrum lines
Weight: 0.85 kg (1.9 lb)
Casing / protective cover: polyurethane, conductive Range, resolution 3 to 200 Hz, 0.5 / 0.25 Hz
at 400 / 800 lines: 3 to 500 Hz, 1.25 / 0.625 Hz
Keypad: sealed membrane 3 to 1000 Hz, 2 .5 / 1.25 Hz
Display: LCD, 4x16 characters LED, backlight 3 to 2000 Hz, 5.0 / 2.5 Hz
adjustable, automatic on/off 3 to 5000 Hz, 12.5 / 6.25 Hz
Memory: typical 500, max. 999 meas. points Lines displayed: 15 highest, toggle Hz / cpm
Backup, memory/clock: approx. 24 h. Lines saved: 1 to 200 highest

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-10. TD-128.B
Machine Condition Tester T30Ex

TAD-22
TRA-34
T30Ex
TAD-23
TAD-24
TAD-20
TAD-25
TAD-21 13980

13882

TRA-35 TEN-10
TEN-11
TRV-26
TEM-11Ex
TRV-27

TRX-16 TRX-17
13881 CAS-14 CAS-15

Part numbers Speed measurement


T30-1Ex Machine Condition Tester T30 Basic Ex 13882 Tachometer probe with cable, Ex
T30-2Ex Machine Condition Tester T30 Logger Ex TAD-20 Contact adapter
T30-3Ex Machine Condition Tester T30 Expert Ex TAD-21 Contact center, rpm, short
13881 Communication module, Ex TAD-22 Contact center, rpm, long
CAB-35 Computer cable, 9 pole female plugs TAD-23 Contact wheel, meter / min.
93162 Cable adapter 9 male/ 25 female TAD-24 Contact wheel, yards / min.
EMD-13 Carrying strap TAD-25 Contact wheel, feet / min.
CAS-14 Carrying case TAD-14 Reflecting tape, pad of 5 sheets
CAS-15 Carrying case with foam insert TAD-16 Reflecting tape for thin shafts, 5 sheets
FUP-01 Follow-up form for T30Ex, pad of 25 (mm)
FUP-03 Follow-up form for T30Ex, pad of 25 (inch) Temperature measurement
TEM-11Ex Temperature probe incl. cable
Shock pulse measurement (SPM) TEN-10 Temperature probe tip surface
TRA-34 Shock pulse transducer, probe assembly, Ex TEN-11 Temperature probe tip liquid
TRA-35 Shock pulse transd. with quick connector, Ex
13980 Earphones, headset with ear defenders, Ex Spare parts
CAB-07 Cable for shock pulse terminal, 1.5 m (5 ft) 13915 Probe tip for TRA-34
13108 Sleeve for probe tip (TRA-34)
Vibration measurement
TRV-26 Vibration transducer M8, Ex 13892 Handle for probe TRA-34
TRV-27 Vibration transducer 1/4" x 28 UNF, Ex CAB-34 Cable for TRA-34
TRX-16 Magnetic foot for vibration transducer CAB-10 Spiral cable for 13980, 13882, TEM-11Ex
TRX-17 Probe for vibration measurement 45011-1.5 Cable for TRA-35
VIC-19 Cable for vibration transducer 90022 Battery, 1,5 V, alcaline, AA-cell

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1999-12. TD-131.B
Machine Condition Tester T30Ex

T30-2 Logger
CAB-35
T30-3 Expert 9 pole
female

9 male /
25 female
13881
93162

T30-1 Basic CAB-10

T30 Ex is a machine condition analyzer designed for a reliable Shock pulse (SPM® dBm/dBc)
preventive maintenance of industrial machines. T30 Ex is available Measuring range: –9 to 99 dBsv
in three versions. With ”Basic”, measuring results are recorded
Resolution: 1 dBsv
manually. ”Logger” is a data logger and works together with SPM
Accuracy: ± 1 dBsv
software Condmaster®Pro. ”Expert” has all the logger features. In
addition, it uses the EVAM® method for vibration analysis. A
”Basic” version can be upgraded to ”Logger” and ”Expert”.
Vibration severity (ISO 10816)
Measuring range: 0.5 to 49.9 mm/s RMS
Measuring techniques Tester T30 Ex (0.02 to 2.0 in/s RMS)
and other features Basic Logger Expert Resolution: 0.1 mm/s (0.01 in/s)
Shock pulse, dBm/dBc • • • Accuracy: ± (0.2 mm/s + 2% of reading)
Vibration severity, ISO 10816 • • • Frequency range: 3 to 1000 Hz
Temperature measurement • • •
Speed, contact and optical • • • Speed measurement
Continuous reading • • • Measuring range: 10 to 19 999 rpm optical
Data logging with Condmaster®Pro • • Measuring distance: max. 0.6 m (2 ft.)
Free value recording • •
Comment recording • • Resolution: 1 rpm
Check point record • • Accuracy: ± (1 rev. + 0.1% of reading)
Continuous recording • •
Vibration spectrum • Temperature measurement
Evaluated vibration analysis • Measuring range: –50 to +440 °C (–58 to 824 °F)
Resolution: 1 °C (1 °F)

Instrument specifications Alternative measuring systems


Intrinsic safety: EEx ib l/llB T4 No. per meas.point: 2
Enclosure: IP43 Additional information: date / time and comments
General features: language selection, battery test,
continuous reading, transducer line
test, automatic idle / power off
Long time recording
Temperature range: 0 to +50 °C (32 to 120 °F) Measuring parameters: SPM, VIB, temperature/speed
Power supply: 6 x 1.5 V LR6 alkaline cells Measuring interval: adjustable 0 - 60 minutes
Battery life: power down 1 year, or 5000 typical
measurements, or continuous
Vibration analysis (EVAM®)
recording 50 hours Window: Hanning
Size: 255 x105 x 60 mm (10 x 4.2 x 2.4 in) Number of samples: 1024 / 2048
FFT result: 400 / 800 spectrum lines
Weight: 0.85 kg (1.9 lb)
Casing / protective cover: polyurethane, conductive Range, resolution 3 to 200 Hz, 0.5 / 0.25 Hz
at 400 / 800 lines: 3 to 500 Hz, 1.25 / 0.625 Hz
Keypad: sealed membrane 3 to 1000 Hz, 2 .5 / 1.25 Hz
Display: LCD, 4x16 characters LED, backlight 3 to 2000 Hz, 5.0 / 2.5 Hz
adjustable, automatic on/off 3 to 5000 Hz, 12.5 / 6.25 Hz
Memory: typical 500, max. 999 meas. points Lines displayed: 15 highest, toggle Hz / cpm
Backup, memory/clock: approx. 24 h. Lines saved: 1 to 200 highest

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-10. TD-129.B
Shock Pulse Transducer with Probe TRA-34

TRA-34

TRA-34 is a hand-held probe, which is used together with


hand-held SPM Tester and Analyzer instruments of Ex de-
sign. The probe is directionally sensitive and must be held
aligned against the bearing and not deviate from this direc-
tion by more than ± 5°. The probe tip is spring loaded and
moves within a sleeve made of chloroprene rubber, SPM
13108, and tolerates 110° C (230° F). Max. permanent tem-
perature for the entire probe is 50° C (120° F). This probe is
per-mitted for use in potentially explosive atmosphere. In-
trinsically safety:
EEx ib I / IIB T4.

Measuring points for the probe transducer should be lo-


cated directly on the bearing housing and the signal path
should be in a direct line to the contact area. The strongest
shock pulses are emitted from the loaded region of the
rolling interface in the bearing. The loaded region for radial
BEX-20 BEX-21
load covers a sector of ± 45° from the load direction, for
axial load the region is 360°. Since the transfer of shock
pulses to the bearing housing is limited by the width of the
bearing, direct radiation of pulses will be restricted to a
sector of ± 60° from the perpendicular to the rolling sur-
face. Measuring points should be clearly marked.

To maintain a steady pressure on the tip, press the probe


tip against the measuring point until the rubber sleeve is in
contact with the surface. Avoid pressing the probe tip against
cavaties and fillets which are smaller than the probe tip.
max. 60°
Part Numbers
TRA-34 Shock pulse transducer, probe assembly
BEX-20 Center drill
BEX-21 Rotary file

Spare Parts
13915 Transducer with probe
13892 Probe handle
CAB-34 Cable for TRA-34
13108 Sleeve for probe tip

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1999-6. TD-90.B
Transducer with Quick Connector and TMU

TRA-35

66
ø 28

TRA-35 is a shock pulse transducer with quick con-nector


that fits all SPM adapters. This transducer is specially de-
signed for applications with potentially explosive atmos-
phere. It is provided with a transducer matching unit (TMU).
Usually the transducer is connected to the instrument via a
1.5 m (5 feet) coaxial cable with TNC connections.

The transducer has bayonet catch. To attach the TRA-35 to


an adapter, push the transducer firmly onto the adapter and
twist it clockwise.

Twist counter clockwise to unfasten the transducer.

Technical Data
Intrinsically safety: EEx ib I / IIB T4
Measuring range: Max. 80 dBsv
Design: Sealed
Temperature range: 0° to + 50° C (32° to +120° F)
Material, spanner: Blacknited steel
Material, handle: Stainless steel
Connector: TNC
Weight: 140 g

Part Numbers
TRA-35 Shock pulse transducer for Ex -conditions
incl. a 1.5 m (5 feet) measuring cable
45011-1.5 1.5 m (5 feet) Measuring cable for
TRA-35 transducer

SPM Instrument AB• Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-91.B
Transducer installation
in potentially explosive atmosphere

Explosive environment None-explosive environment

Only connect instru-


ments with applicable Coupling
certificate directly Trans-
to the transducer! Connection to
former non-exproof
A30 Ex instruments and
T30 Ex measuring units
A2011Ex
T2001Ex

Shock Pulse Transducers Coaxial cable


max. 100 m

General Use with normal instruments


Shock pulse transducers with ex-proof certificates must al- In permanent SPM installations for continuous monitoring,
ways be used in connection with a corresponding approved and when used together with a standard hand-held instru-
coupling transformer, see table below. Ex proof instruments ment, the coupling transformer must be placed in a none-
from SPM can, anyhow, be directly connected if the envi- explosive environment, as shown above.
ronmental conditions permit. If an ordinary measuring in-
strument is connected directly to it, there is a risk for
damaging the transducer. Use with ex-proof instruments
Inside the area with potentially explosive atmosphere only
The transducer is installed like any standard SPM trans- instruments with certificates covering the environmen-
ducer, see the installation manual SPM 71421. The trans- tal conditions must be directly connected to the trans-
former is screw mounted (2 mounting holes ø 4 mm). ducer covered by the NEMKO certificate No Ex 97D247 X.
The maximum cable length between transducer and trans-
former is 100 m. The transformer has a TNC connector on
the transducer side, a BNC connector on the instrument
side.

Ex-proof certificate: NEMKO Nr. Ex 97D247 X SP Ex-95.D.611X


Intrinsic safety designation EEx ia I/IIC T4 EEx ib I / IIB T4

Shock pulse transducer: 42011 / 42111 42010 / 42110


Coupling transformer: 14196 13862

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-10. TD-115.B
Transducer and transformer
for potentially explosive atmosphere

50 32
35
Type SPM 42011
Temp. -20°C to +80°C
EEx ia I/IIC T4
N Ex 97D247 X

METER

COUPLING

57
TRANSFORMER
TYPE SPM 14196

80
13862
[EEx ib]
[EEx ia]I /I/IIC
IIB
N Ex 95.D.611X
SP Ex 97D247 X
R

50Ω LINE

ø4
17

Shock Pulse Transducers


Explosive environment None-explosive
Transducer SPM 42011 (M8) and SPM 42111 (UNC 5/16"), environment
NEMKO Cert. No. Ex 97D247 X, must be used together
Only connect instruments
with coupling transformer SPM 14196 when connected to
with applicable certificate
external measuring units. The transducers fit all existing directly to the transducer!
Connection to
SPM shock pulse monitoring systems except MINEX. They non-exproof
are installed inside the area with potentially explosive at- instruments
mosphere in the same way as any standard SPM transducer. and measuring
Transducer
units
The Ex approved instruments, covered by the NEMKO cer- 42011 / 42111
tificate Ex 96D001, can be connected directly to the trans-
A30 Ex
ducers if the environmental conditions permit. T30 Ex Coupling Trans-
former
14196
Coupling Transformer
Coupling transformer SPM 14196, NEMKO Cert. No.
Ex 97 D247 X, connects the ex-proof transducers to the Coaxial cable max. 100 m
measuring equipment. While the transformer itself is ex-
proof, it should always be mounted in none-explosive envi-
ronment. The maximum cable length from the transducer
via the transformer to the instrument is 100 m.

Technical data, transducer 20


Ex Designation EEx ia I/IIC T4 6.9
6.8
(6.6)
Measuring range: Max. 80 dBSV (6.5)
Temperature range: – 20° C to + 80° C
External overpressure: Max. 0.7 MPa (7 bar)
Design: Stainless, acid proof steel, AISI 316,
sealed
Connector type: TNC
Torque limit: 15 Nm

Technical data, transformer


Ex Designation [EEx ia] I/IIC M8
(UNC 5/16")
Temperature range: – 20° C to + 55° C
Design: Fenylen oxide plastic, epoxy resin,
sealed
Connector type: TNC to transducer, BNC to
instrument

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-11. TD-116.B
Tachometer Probe 13882

TAD-23
TAD-24
13882 TAD-21 TAD-25 TAD-22

CAB-10
TAD-14
TAD-20
TAD-16

The Tachometer Probe 13882 is used together with hand-


held instruments, e.g. Analyzer A30Ex/Tester T30Ex for
optical measurement of the rate of rotation and for contact
measurement of as well the rate of rotation as the periph-
eral speed. This equipment is also permitted to be used in
atmosphere with a potential risk for explosions.

Optical Measurement of the Rate of Rotation Max. 45°


A light beam is directed against a reflecting tape on the
rotating object, from a distance of max. 0.3 m and from an
angle of max. 45°.

Contact Measurement of rpm


The contact adapter TAD-20 with a rubber tipped contact
centre, TAD-21/22, is screwed onto the tachometer probe
and then held against the centre of a shaft end or a wheel.

Contact Measurement of Peripheral Speed


The contact adapter TAD-20 with contact wheel is held
against the circumference of a shaft, a belt, etc. The speed
is read out in units, depending on which contact wheel is
used:

Meters per minute – use TAD-23, divide result by 10


Yards per minute – use TAD-24, divide result by 10
Feet per minute – use TAD-25, divide result by 2.

Part Numbers
13882 Tachometer probe with cable
CAB-10 Spiral cable TAD-23 = 0.1 m / min.
TAD-20 Contact adapter TAD-24 = 0.1 yd. / min.
TAD-21 Contact centre, rpm, short TAD-25 = 0.5 ft / min.
TAD-22 Contact centre, rpm, long
TAD-23 Contact wheel, meter/min.
Technical Data
TAD-24 Contact wheel, yards/min.
TAD-25 Contact wheel, feet/min. Intrinsically safety: EEx ib I / IIB T4
TAD-14 Reflecting tape, pad of 5 sheets Measuring range: max. 19 999 rpm optical
TAD-16 Reflecting tape for thin shafts, 5 sheets Measuring distance: max. 0.3 m (1 ft.)
Dimensions, 13882: 171 x ø 42 mm
Temperature range 0 to +50° C ( 32 to 120° F)

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-93.B
Temperature Probe TEM-11Ex

TEM-11Ex

TEN-10 TEN-11

CAB-10

The Temperature Probe TEM-11Ex is used together with


SPM's handheld instruments of types Analyzer A30Ex and
Tester T30Ex for measurement and recording of tempera-
tures, also in environment with risk for explosion.

Connection of probe and probe tips


The probe, TEM-11Ex, is connected via its spiral cable,
CAB-10, to the EXT connector of the instrument. This con-
nector is also used for computer and tachometer probe.
The TEMP menu turns up on the instrument as soon as the
temperature probe is connected. It is also power supplied
by the instrument. See further on in the instrument manual.
Two probe tips belong to TEM-11Ex:
• TEN-10 for measuring surface temperature on solids
• TEN-11 for measuring temperatures of liquids
When using a probe tip its connector is input into the front Ordering numbers
socket of the probe. TEM-11Ex Temperature probe with cable
CAB-10 Spiral cable
TEN-10 Probe tip for surface temperature of solids
Temperature measurement
TEN-11 Probe tip for temperature of liquids
• connect TEM-11Ex to the instrument
• input the desired probe tip
• remove the protectice cap (TEN-10) Technical specifications
Measuring range: 0 to + 300 °C
• the instrument is set for temperature measurement
(+ 32 to + 572 °F)
• press the probe tip carefully against the component
Max. offset: ± 5 °C (± 9 °F)
surface alternatively into the liquid
Measuring uncertainty ± 1 °C
• keep the M button depressed until a reading value Sensitivity 10 mV/ °C
appears on the screen. Output range 0 to 3 V DC
Power supply + 5 V DC
Measuring time: approx 1 minute
Handling Dimensions, TEM-11Ex: ø 42 x 118 mm
Handle and store the probe tips with care. The protective TEN-10: length 122 mm (with cap)
cap of the TEN-10 should always be kept on when not in TEN-11: length 159 mm
use. Weight, TEM-11Ex: 94 g

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-11. TD-140.B
Vibration Transducer TRV-16/17

Measuring direction
17 SPM 93022 /
SPM 93121
ø 27.5
Cable

36
clamp

9
TRV-16: t = M8 t
TRV-17: t =1/4 x 28 UNF
ø 15

Transducer TRV-16/17 is piezo-electric accelerometer of com-


pression type for vibration monitoring of industrial machin- SPM 13008
ery. Intended for use with handheld instruments or for 1
permanent installations in potentially explosive atmosphere.
Max. cable length between transducer and measuring unit
is 10 m (33 ft).

The transducer is mounted against a smooth, flat sur-face


on the machine. TRV-16 = thread size M8, TRV-17=1/4 x 28
UNF. The transducers are delivered with three washers,
each adjusting the connector angle 90°. The low noise
coaxial cable (SPM 90176-L) with TNC connector must be 2
secured with a clamp close to the transducer on stationary
installations.

For installations in moist environments, use sealing TNC Installation using the
cable plugs SPM 13008 to prevent cable corrosion and magnet foot TRX-16
cause signal loss (1).

If a magnet foot is mounted, the plain seat surface must be


min. ø 27 mm (2). Probe for handheld use is screwed di-
rectly on the transducer bottom tap (3).
3
Technical Data
Intrinsically safety: EEx ib I/IIB T4
12 pC / m / s2 *
Nominal sensitivity, main axis:
Transverse sensitivity: < 10% Using probe TRX-17
mounted on the
typ. 0.01 m / s2 / µ strain
Typical base strain sensitivity: transducer
Linear frequency range: 0 to 1000 Hz
Temperature range: 0 to 50°C (32 to 120°F)
Typical temperature drift: 0.25 % / °C
Casing: Acid proof steel
(SS 2382 / AISI 316)
Design: Sealed
Weight: 135 grams (5 oz)
Connector type: TNC
ø 6.9 min. 16 M8
Torque limit (17 mm wrench): 10 Nm (7.4 lbf · ft),
* Individual value given on the calibration chart.
min. 10
min. 12

Mounting Tools
max. 0.7

81027 Holder for counterbore


81057 Counterbore, diam. 20 mm
81030 Pilot for 1/4" x 28 UNF (TRV-17)
81031 Pilot for M8 (TRV-16)

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-8. TD-94.B
Vibration Transducer TRV-26 / 27

Measuring direction
17

ø 27.5

Cable

36
clamp

9
t TRV-26: t = M8
ø 15 TRV-27: t = UNF 1/4"- 28

The transducers TRV-26 and TRV-27 are piezo-electric ac-


celerometers of compression type, designed for vibration
monitoring of industrial machinery. Intended for use with SPM 13008
handheld instruments in potentially explosive atmosphere.
The transducer is mounted in a threaded hole on a smooth,
flat surface on the machine. It is delivered with three wash-
ers for adjusting the connector angle. Each washer turns the
transducer 90°. Fix low noise coaxial cable (SPM 90176-L or
90292-L) with TNC connector with a clamp close to the
transducer.

For installations in moist environments, use sealing TNC


cable plugs SPM 13008 to prevent cable corrosion.
Installation in moist environments

Technical data
Intrinsically safety: EEx ib I/IIB T4
Nominal sensitivity, main axis: 10 pC/m/s2 ± 20% *
Transverse sensitivity: max. 10%
Typical base strain sensitivity: 0.01 m/s2/m strain
Linear frequency range: 0 to 5000 Hz
Max. peak acceleration: 600 m/s2 ø 6.9 min. 16 M8
Temperature range: 0° C to +50° C (ø 5.5) (UNF
(+32° F to +120° F) 1/4"-28)
Typical temperature drift: 0.25% / °C
Casing: Stainless, acid proof steel,
min. 10
min. 12

max. 0.7

SS 2382/AISI 316
Design: Sealed
Sealing: IP 65 with TNC connector
IP 67 with conn. SPM 13008
Weight: 145 grams (5 oz)
Connector type: TNC
Torque limit: 10 Nm (7.4 lbf/ ft) Part Numbers
* Individual value given on the calibration chart. TRV-26 Vibration transducer, M 8
TRV-27 Vibration transducer, UNF 1/4"-28
13008 Sealing TNC cable plug
81027 Holder for counterbore
81057 Counterbore, diam. 20 mm
81030 Pilot for UNF 1/4" (TRV-27)
81031 Pilot for M8 (TRV-26)

To drill the mounting hole, use drill bit 6.9 mm (M8) or 5.5
mm (UNF 1/4"-28). Torque and unscrew the transducer with
a torque wrench and a 17 mm socket (SPM 81086).

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1999-10. TD-136.B
Vibration Transducer TRV-28/29

Measuring direction

17

ø 27.5
Cable
clamp

36
to transducer
interface

9
t TRV-28: t = M8
ø15 TRV-29: t = UNF 1/4"- 28

The transducers TRV-28 and TRV-29 are piezo-electric


accelerometers of compression type with built-in pre- Explosive None-explosive
amplifier, designed for vibration monitoring of industrial environment environment
machinery inside the area with potentially explosive atmos-
13008
phere. It must be used together with transducer interface Transducer
interface
SPM 14423, 14424 or 14540 when connected to an external
measuring unit. The transducer interface should always be
mounted in none-explosive environment. The cable length TRV-28/29 max. 50 m
between transducer and measuring unit via the interface is to measuring
max. 50 m. equipment

The transducer is mounted against a smooth, flat surface on


the machine. The transducers are delivered with three wash-
Typical frequency response
ers for adjusting the connector angle. Each washer turns the
transducer 90°. The coaxial cable (SPM 90005-L or 90267-L)
with TNC connector must be secured with a clamp close to
the transducer. In moist environments, use sealing TNC
cable plugs SPM 13008 to prevent cable corrosion.

Technical data
Intrinsically safety: EEx ia I/IIC T4
Nominal sensitivity, main axis: 3.3 mV/mm/s *
Transverse sensitivity: max. 10% ø 6.9 min. 16 M8
2
Typical base strain sensitivity: 0.01 m/s /µ strain (ø 5.5) (UNF
1/4"-28)
Linear frequency range: 3 to 5000 Hz
min. 10
min. 12

Max. peak acceleration: 600 m/s2


max. 0.7

Temperature range: -20° C to +100° C


(-4° F to +210° F)
Casing: stainless steel, acid proof,
AISI 316 (SS 2382)
Part Numbers
Design: sealed
TRV-28 Vibration transducer Ex, M 8
Connector tightness: IP 65 with TNC connector TRV-29 Vibration transducer Ex, UNF 1/4"-28
IP 67 with conn. SPM 13008 13008 Sealing TNC cable plug
Connector type: TNC 81027 Holder for counterbore
81057 Counterbore, diam. 20 mm
Weight: 145 grams (5 oz)
81030 Pilot for UNF 1/4" (TRV-29)
Torque limit: 10 Nm (7.4 lbf · ft) 81031 Pilot for M8 (TRV-28)
Cable length: max. 50 m (165 ft)
To drill the mounting hole, use drill bit 6.9 mm (M8) or 5.5
mm (UNF 1/4"-28). Torque and unscrew the transducer with
* Individual value given on the calibration chart.
a torque wrench and a 17 mm socket (SPM 81086).

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-09. TD-127.B
Vibration Transducer Interface 14423

None-explosive environment

to transducers
to measuring units
type TRV-28 /
and instrument
TRV-29
1 1
in explosive
environment power supply
89

79
2 2
12 - 24 V DC

mounting screws 144


ø4
160

30
The transducer interface 14423 is a two channel interface Technical data
for mounting in non-hazardous area and connected to the
Intrinsically safety: [EEx ia] I/IIC T4
certified intrinsically safe vibration transducers TRV-28 and
TRV-29. The transducers are connected via coaxial cables Channels: 2
with SMB connectors. Transducer type: TRV-28, TRV-29

The transducer interface provides a galvanically separated Power supply: 12 to 24 V DC


connection between the intrinsically safe vibration trans- (± 10% according to EN 50082-2)
ducer, which can be installed in potentially explosive atmos- Supply current: max. 40 mA
phere, and various SPM vibration measuring devices. The
Temperature range: -20° C to +70° C
interface and the measuring devices must be installed in a
non-explosive environment. Transducer and interface are Dimensions: 89 x 160 x 30 mm
connected to a common equipotential ground circuit.
Ordering number / connector type (output signal):
The transducer measures vibration velocity and outputs a
voltage, nominally 3.3 mV/mm/s. This signal is converted 14423 A: SMB connectors for VCM (mV/m/s2)
into three different outputs: mV/m/s2 for VCM measuring and portable instruments (pC/m/s2)
units, µA/mm/s for VMS measuring units, and pC/m/s2 for
14423 B: SMB connectors for VMS (µA/mm/s)
MG4 and portable instruments.
and portable instruments (pC/m/s2)
The transducer interface is available in four versions with
14423 C: Screw terminals for VCM (mV/m/s2)
different connector configuration for the measuring de-
and VMS (µA/mm/s),
vices.
SMB for instruments (pC/m/s2)
The interfaces do not have a complete enclosure and need
to be mounted in a box or cabinet with a degree of protec- 14423: SMB connectors for MG4 (pC/m/s2)
tion appropriate for the environmental conditions but at and portable instruments (pC/m/s2)
least IP20.

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2001-11. TD-149.B
Vibration Transducer Interface 14540

None-explosive environment
to measuring units
and instrument
to transducers
type TRV-28 / 1
1
TRV-29
2
2
in explosive
environment

117
3
127 3

4 power supply
4 12 - 24 V DC

mounting screws 144


ø4
160

30
The transducer interface 14540 is a 4 channel iinterface for Technical data
mounting in non-hazardous area and connected to the certi-
Intrinsically safety: [EEx ia] I/IIC T4
fied intrinsically safe vibration transducers TRV-28 and TRV-
29. The transducers are connected via coaxial cables with Channels: 4
SMB connectors. Transducer type: TRV-28, TRV-29

The transducer interface provides a galvanically separated Power supply: 12 to 24 V DC


connection between the intrinsically safe vibration trans- (± 10% according to EN 50082-2)
ducer, which can be installed in potentially explosive atmos- Supply current: max. 80 mA
phere, and various SPM vibration measuring devices. The
Temperature range: -20° C to +70° C
interface and the measuring devices must be installed in a
non-explosive environment. Transducer and interface are Dimensions: 127 x 160 x 30 mm
connected to a common equipotential ground circuit.
Ordering number / connector type (output signal):
The transducer measures vibration velocity and outputs a
voltage, nominally 3.3 mV/mm/s. This signal is converted 14540 A: SMB connectors for VCM (mV/m/s2)
into three different outputs: mV/m/s2 for VCM measuring and portable instruments (pC/m/s2)
units, µA/mm/s for VMS measuring units, and pC/m/s2 for
14540 B: SMB connectors for VMS (µA/mm/s)
the portable instruments T30/A30.
and portable instruments (pC/m/s2)
The transducer interface is available in three versions with
14540 C: Screw terminals for VCM (mV/m/s2)
different connector configuration for the measuring de-
vices. and VMS (µA/mm/s),
SMB for instruments (pC/m/s2)
The interfaces do not have a complete enclosure and need
to be mounted in a box or cabinet with a degree of protec-
tion appropriate for the environmental conditions but at
least IP20.

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-09. TD-152.B
Vibration Transducer Interface 14424

None-explosive environment

to measuring units
to transducers and instrument
type TRV-28 / 1 1
TRV-29
2 2
in explosive
environment 3 3

4 4

194
5
204

6 6

7 7

8 8 power supply
12 - 24 V DC

30
mounting screws 144
ø4
160

The transducer interface 14424 is a 8 channel interface for Technical data


mounting in non-hazardous area and connected to the certi-
Intrinsically safety: [EEx ia] I/IIC T4
fied intrinsically safe vibration transducers TRV-28 and TRV-
29. The transducers are connected via coaxial cables with Channels: 8
SMB connectors. Transducer type: TRV-28, TRV-29

The transducer interface provides a galvanically separated Power supply: 12 to 24 V DC


connection between the intrinsically safe vibration trans- (± 10% according to EN 50082-2)
ducer, which can be installed in potentially explosive atmos- Supply current: max. 160 mA
phere, and various SPM vibration measuring devices. The
Temperature range: -20° C to +70° C
interface and the measuring devices must be installed in a
non-explosive environment. Transducer and interface are Dimensions: 204 x 160 x 30 mm
connected to a common equipotential ground circuit.
Ordering number / connector type (output signal):
The transducer measures vibration velocity and outputs a
voltage, nominally 3.3 mV/mm/s. This signal is converted 14424 A: SMB connectors for VCM (mV/m/s2)
into three different outputs: mV/m/s2 for VCM measuring and portable instruments (pC/m/s2)
units, µA/mm/s for VMS measuring units, and pC/m/s2 for
14424 B: SMB connectors for VMS (µA/mm/s)
the portable instruments T30/A30.
and portable instruments (pC/m/s2)
The transducer interface is available in three versions with
different connector configuration for the measuring de- 14424 C: Screw terminals for VCM (mV/m/s2)
vices. and VMS (µA/mm/s),
SMB for instruments (pC/m/s2)
The interfaces do not have a complete enclosure and need
to be mounted in a box or cabinet with a degree of protec-
tion appropriate for the environmental conditions but at
least IP20.

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 2000-09. TD-150.B
10
Special Products

71700 B © SPM Instrument AB. ISO 9001 certified.


Shock Pulse Monitor SPM 12339

175
25
75
175

The refiner disc segments can be fine adjusted using the


SPM Shock pulse Monitoring method. A shock pulse trans-
ducer measures the mechanical shocks arising when the
TRA30
disc segments touches each other.

A E
• A shock pulse transducer (A) is fixed to the refiner
B
housing on an installed adapter (B) so that mechanical
shocks from the segments are transmitted to the
transducer with a minimum of reduction. A permanent
transducer (C) can also be used.
• The transducer signal is transmitted via the cables (E
C
and F) and the transducer matching unit (D) to the SPM
D
electronics (G) which analyses the frequency of
occurance and magnetude.
• The instrument (lower fig.) indicates the range between
first touch and a running together of the disc seg-
ments.
• Zerosetting can be made very accurate without the risk F G
of any damage to milling discs.
• During normal operation the instrument reading is 40 -
60 %. If the discs run together, corresponding to an
instrument reading above 70 %, a relay closes and a
signal is given to open the disc gap.

Technical data
Input TNC connector for the Transducer
Match-ing Unit TMU-12 and the shock
pulse transducer TRA-30 alt.
SPM 40000
Relay output Max. 220 V AC, 100 VA
Instr. output For remote indicator 4 - 20 mA
Power supply 110/220 V AC, 50/60 Hz
Casing Sealed polycarbonate box
Dimensions 175 x 175 x 75 mm
Weight 1.1 kg Disc gap

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-7. TD-24.B
Induction Heater IND-10 / 11

12094

12139
12095

12096 12140
IND-10 / IND-11

Induction heater IND-10 and IND-11 are used to heat ring Example of heatingtime
shaped, metal objects weighing up to 7 kg (15 lb), with a
minimum bore diameter of 15 mm (0.6 in). Heat is gener- °C
ated by a low voltage, high amperage AC flow through the 100
work piece.
90
The heater has a capacity of 3.3 kVA, allowing to heat a 4 kg 80
(8.8 lb) bearing to 100° C (210° F) in less than two minutes.
The heater casing is made of polyurethane foam and can 70
withstand contact temperatures of up to 140° C (285° F). 60
Bearing 6318
The heater is easy and safe to use. All controls and signal 50 Weight 4,9kg (10.8 lb)
lamps are conveniently placed on the front panel. 40
The work piece is automatically demagnetized at end of the
30
timer controlled heating cycle, to better than 2 A/cm.
20
The heater can also be used as a demagnetizer by selecting
10
the shortest heating time, 0.2 minutes.
0,5 1 1,5 2 2,5 3 3,5 4 4,5 5

Minutes

Part numbers Technical data


IND-10 Induction Heater 230V, with 2.5 m Dimensions (w x d x h): 300 x 230 x 240 mm
power cable, set of 3 standard yokes (11.8 x 11.8 x 9.4 in)
Space between yoke supports: 100 x 100 mm
IND-11 Induction Heater 115V, with 2.5 m (3.94 x 3.94 in)
power cable, set of 3 standard yokes Weight, heater only: 22 kg (48.5 lb)
Weight with standard yokes: 30 kg (66 lb)
Standard yokes Mains power IND-10: 230 V, 50-60 Hz
12094 Yoke 14 x 14 x 240 mm (0.55 x 0.55 x 9.4 in) Mains power IND-11: 115 V, 50-60 Hz
12095 Yoke 30 x 30 x 240 mm (1.18 x 1.18 x 9.4 in) Max. power consumption: 3.3 kVA
12096 Yoke 55 x 55 x 240 mm (2.17 x 2.17 x 9.4 in) Residual magnetism after
demagnetization: better than 2 A/cm
Yokes, optional Timer range: 0.2 to 10 minutes
12139 Yoke 20 x 20 x 240 mm (0.79 x 0.79 x 9.4 in)
12140 Yoke 45 x 45 x 240 mm (1.77 x 1.77 x 9.4 in)

SPM Instrument AB • Box 4 • S-645 21 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • [email protected] • www.spminstrument.se ISO 9001 certified. © Copyright SPM 1998-7. TD-17.B