Revision number Page

Technical data 1

Sanicubic 2 Pro
Customer Supplier
Company name SFA Vietnam
Dept.
Editor
Phone number
Fax no.
E-mail
Operating data specification
Pumped fluid Water Rated flow l/s
Kind Rated head m
Solids
Percentage of solid content 0 Geodetic head m
pH value Available system NPSH m
Temperature °C 20 Inlet pressure (pin) kPa 0
Density kg/m³ 998,3 Altitude above sea level m 100
Kin. viscosity mm²/s 1,005
Vapour pressure kPa 2,34

Pump
Make SFA Impeller type Roue dilacératrice Pro X K2
Pump type Sanicubic 2 Pro Impeller construction
Frame size Max. mm 0
Design Impeller Ø designed mm
Self priming Yes Min. mm 0
Speed 1/min 2.800 Nominal l/s 2,19
Max. operating pressure kPa 131 Flow Max. l/s 3,92
Max. diff. pressure kPa 131 Min. l/s 0
Stages 1 Nominal m
No. of diffusers 1 Head Max. m 1,49
Pressure rating Min. m 13,4
Suction port Nominal pipe size Shut off head m 13,4
Standard NPSH3 m
Pressure rating Shaft power kW
Discharge port Nominal pipe size Shaft power P2(Q=max.) at max. impeller kW 1,39
Standard Efficiency

Materials
Pump Shaft seal
Material code

Motor Coupling
Make/Type SFA Sanicubic 2 Pro Make/Type
Specific design Asynchrone à condensateur permanent / 50 HzSeries
/ Pole pairs 2
Rated power kW Speed 1/min Spacer length mm
Electric voltage V Electric current A Frame size
Degree of protection IP68 Frame size
Type of protection Explosion protection
Remark

Project Creation software Issue date Last update


Spaix® 5-2022.1 - 2022/09/08 (Build
24.April.2024
540), 64 bit 24.April.2024
Revision number Page
Performance curves 2

Sanicubic 2 Pro
Customer Supplier
Company name SFA Vietnam
Dept.
Editor
Phone number
Fax no.
E-mail
Impeller Impeller type Roue dilacératrice Pro X K2
Ø Flow Head Shaft power P2 Impeller construction
Value range h h P2(Q=Max) h
Sense of rotation Clockwise from the drive end
Min. Max. Max. H(Q=0) Max. P2(Q=0) Max.
mm l/s l/s l/s m m kW kW kW Bearing bracket
Actual 0 3,92 2,19 13,4 8,18 0,999 1,39 1,17 Outlet width mm
Min. 0 / / 2,19 13,4 8,18 0,999 1,39 1,17 Frequency Hz 50 Hz
Max. 0 / / 2,19 13,4 8,18 0,999 1,39 1,17 Speed 1/min 2.800

Power data referred to: Water; 20°C; 998,3kg/m³; 1,005mm²/s Reference no.
Series Sanicubic 2 Pro
Frame size

H/ m Head — Sanicubic 2 Pro ∆p / kPa


13,6
132
13,2
128
12,8
124
12,4
120
12
116
11,6
112
11,2
108
10,8
104
10,4
100
10
96
9,6
92
9,2
88
8,8
84
8,4 Eff. 14,9%
80
8
76
7,6
72
7,2
68
6,8
64
6,4
60
6
56
5,6
52
5,2
48
4,8

4,4 44

4 40

3,6 36

3,2 32

2,8 28

2,4 24

2 20

1,6 16

1,2 12

0,8 8

0,4 4
▕◄ Application range ►▏
0 0
0 0,4 0,8 1,2 1,6 2 2,4 2,8 3,2 3,6 Q / l/s

Project Creation software Issue date Last update