Modul 4-1 DataLink Layer
Modul 4-1 DataLink Layer
[email protected]
Electronic Engineering Polytechnic Institut of Surabaya – ITS
Kampus ITS Sukolilo Surabaya 60111
Pendahuluan
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
MAC (Media Access Control) Address
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
Pengiriman Data
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
Pengiriman data pada DataLink Layer
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
Metode CSMA/CD
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
Error Checking Pengiriman Data
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
Data Pada DataLink Layer
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
Generic Data Link Frame Format
Address Field
We saw how IEEE 802.3 uses Destination and Source Addresses.
By the way: Any idea how a serial data link frame is addressed?
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
Generic Data Link Frame Format
Type Field
Usually information indicating the layer 3 protocols in the data field, I.e. IP Packet.
Type field values of particular note for IEEE 802.3 frames include:
0x0600 XNS (Xerox)
0x0800 IP (the Internet protocol)
0x8137 Novell NetWare packet formatted for Ethernet II
0x6003 DECNET
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
“Ethernet” Frame Formats
Length Field
In some frame formats such as 802.3, there is a length field which specifies
the exact length of a frame.
802.3
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
1. To accommodate more protocols IEEE added the SNAP
(Subnetwork Access Protocol) header.
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
The fields of various Ethernet framing that are used for
identifying the type of data contained in a frame:
Ethernet II or DIX (DEC, Intel, Xerox) – Most common
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
Generic Data Link Frame Format
Data Field
Included along with this data, you must also send a few other bytes.
They are called padding bytes, and are sometimes added so that the
frames have a minimum length for timing purposes.
LLC bytes are also included with the data field in the IEEE standard frames.
(later)
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
Data Encapsulation Example
Layer 2:
Network
Layer
010010100100100100111010010001101000… Layer 1: Physical
Layer
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
Generic Data Link Frame Format
FCS
Used to insure that the data has arrived without corruption.
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
Three Kinds of FCS
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111
Generic Data Link Frame Format
[email protected] Electronic Engineering Polytechnic Institut of Surabaya – ITS Kampus ITS Sukolilo 60111