TECHNICAL DATA Configuration: RQ051380-CF01-Rev003

Technical data
Boiler plant concept: ................................................................................................ 1 x MISSION™ OC
Request:.................................................................................................................................... RQ051380
Configuration: ........................................................................................................................................01
Configuration revision:.........................................................................................................................003
Hull No.(s):........................................................................... H4001-02-03-04-05-06-07-08-09-10-11-12
Order(s): .............................................................................. 739756-57-58-59-60-61-62-63-64-65-66-67

Boiler plant
Pressure gauge scale:............................................. Multiscale (bar, MPa, kg/cm2)
Thermometer calibration: .................................................................................. °C
Language on signs:.................................................................................... English
Operation:...................................................................................... 24h unattended
Classification society:....................................................................................... GL
Sub-notification:...............................................................................................NA
Insulation class: ................................................................................................... F
Flange standard................................................................................................. EN
Boiler ambient temperature: ......................................................................... 45 °C
Boiler design feed water temperature:.......................................................... 80 °C
Boiler operating feed water temperature: ................................................ 85-95 °C
Power supply: .........................................................................................3 x 440 V
Control voltage:............................................................................................230 V
Pilot voltage: ..................................................................................................24 V
Frequency:.................................................................................................... 60 Hz
Remote control PC: ...........................................................................................No
MODBUS protocol for communication with main ship control system: ..........No

QOS Release 5.5.54 Page 1/5


TECHNICAL DATA Configuration: RQ051380-CF01-Rev003

MISSION™ OC boiler

General data

Boiler family: ..............................................................................MISSION™ OC


Type:................................................Vertical, composite smoke/water tube boiler
Height (excl. mountings):....................................................................... 5159 mm
Extension length of the water level device:............................................ 1800 mm
Boiler diameter (incl. insulation): .......................................................... 3770 mm
Approx. weight (excl. water):................................................................... 39.3 ton
Approx. weight (incl. water): ................................................................... 56.7 ton
Steam output, oil fired section:.............................................................. 2500 kg/h
Steam output, exhaust section: .............................................................. 2500 kg/h
Design pressure: .......................................................................................... 9 barg
Test pressure:.......................................................................................... 13.5 barg
Working pressure: ....................................................................................... 7 barg
Working temperature:.............................................................................. 170.4 °C
Water level measurement: ............................................................................... Yes
Number of water level measurement elements (per boiler): ................................1
Number of burners (per boiler): ...........................................................................1
Local control panel:......................................................................................... Yes
Feed water operation: .......................................................................... Modulating
Boiler body paint:......................................Anti corrosion and heat resistant paint
Insulation:........................................................................................................ Yes
Insulation thickness: ................................................................................... 75 mm
Cladding type: .............................................................................................Trapez
Cladding colour: ...................................................................... Glavanized(Silver)
Counter flanges for boiler and oil system included:........................................ Yes
Counter flanges for smoke uptake:.................................................................. Yes
Counter flanges for exhaust gas inlet and outlet: ............................................ Yes

1. Exhaust gas data

Main engine:........................................................................................ 6L70MC-C


Engine design load: .............................................................................. 90% MCR
Exhaust gas flow: ...............................................................................167900 kg/h
Design condition: ............................................................................................ ISO

QOS Release 5.5.54 Page 2/5


TECHNICAL DATA Configuration: RQ051380-CF01-Rev003

Inlet temperature of exhaust gas:............................................................. 228.5 °C


Outlet temperature of exhaust gas: .......................................................... 194.0 °C
Pressure loss across boiler:................................................................. 120 mmWC

2. Burner

Burner family: ....................................................................................KBO-R15M


Burner location:.............................................................................................. Side
Burner type:......................................................................................... Modulating
Colour of burner: ..........................................................................Red (RAL3000)
Primary fuel:........................................................................ Heavy fuel oil (HFO)
Secondary fuel:..............................................................................Diesel oil (DO)
Burner capacity on diesel oil, min:............................................................ 64 kg/h
Burner capacity on diesel oil, max: ......................................................... 185 kg/h
Density of diesel oil:................................................................ 850 kg/m3 at 15 °C
Burner capacity on heavy fuel oil, min: .................................................... 64 kg/h
Burner capacity on heavy fuel oil, max.:................................................. 190 kg/h
Density of fuel oil:................................................................... 980 kg/m3 at 15 °C
Diesel oil caloric value (min.): ............................................................ 42.2 MJ/kg
HFO caloric value (min): .................................................................... 40.2 MJ/kg
Max. HFO viscosity: ................................................................... 700 cSt at 50 °C
Min. HFO temperature before preheater: ..................................................... 60 °C
HFO temperature at burner inlet: ............................................................... 145 °C
Min. / max. diesel oil viscosity: ............................................... 3 / 12 cSt at 50 °C
HFO viscosity (at burner):........................................................................ 8-10 cSt
Ambient air temperature:.............................................................................. 45 °C
Air excess ratio at 100%:.................................................................................1.20
Flue gas temperature (clean boiler): ........................................................... 350 °C
Air consumption at 100% load:............................................................. 2900 kg/h
Flue gas flow: ........................................................................................ 3080 kg/h
Pressure loss – Flue gas funnel – Max. .............................................5-10 mmWC
Pressure loss across convection section: .............................................. 85 mmWC
Nozzle: ...........................................................................................12-W2-180-60
Flame tube: .................................................................................................OD270
Diffuser disc: ..............................................................................................195x75
Pre-wired: ........................................................................................................ Yes

3. Local control panel

Control panel cabinet colour: .................................................................RAL7032

QOS Release 5.5.54 Page 3/5


TECHNICAL DATA Configuration: RQ051380-CF01-Rev003

Display panel:................................................................................................. Text


Protection class:.............................................................................................. IP55
Automatic mode: ............................................................................................. Yes
Manual mode:.................................................................................................. Yes
Emergency mode:............................................................................................ Yes
Communication with power management system:.......................................... Yes
Control of burner unit:..................................................................................... Yes
Hardwired remote monitoring of steam pressure and water level:.................. Yes
Monitoring of flue gas temperature (oil-fired section):................................... Yes
Remote shut off: .............................................................................................. Yes
Control technology:.......................................................................Microprocessor
Hard wired remote monitoring of fuel oil pressure: ........................................ Yes
Control of fuel oil pumps: ............................................................................... Yes
Alarm for oil content in hot well: .................................................................... Yes
Salinity alarm equipment: ............................................................................... Yes
Control of feed water pumps: ............................................................................No
Monitoring of chemical dosing unit: ............................................................... Yes
Control of steam dump valve: ...........................................................................No
Monitoring of exhaust gas temperature (exhaust gas section): ....................... Yes
Emergency stop box: .........................................................................................No
Monitoring of smoke density: ...........................................................................No
Ammeter for fuel oil pumps: .............................................................................No
Hour counter for fuel oil pumps: .......................................................................No
Ammeter for feed water pumps:........................................................................No
Hour counter for feed water pumps:..................................................................No
Ammeter for burner motor: ............................................................................. Yes
Hour counter for burner motor: ....................................................................... Yes
Max. allowed power for direct online motor start:......................................75 kW

4. Water level gauge glass

Type:...................................................................................................... Reflective
Closing type: ............................................................................. Remote operation

Boiler water test kit

Boiler water test kit: ........................................................................................ Yes

QOS Release 5.5.54 Page 4/5


TECHNICAL DATA Configuration: RQ051380-CF01-Rev003

Chemical dosing unit

Type of chemical dosing unit: ................................................Modulating - 9 barg

Feed water pumps

1. Design criteria for feed water pumps

Please note that the values are guidelines only (to be verified by Shipyard)
Capacity per pump: .................................................................................. 8.0 m3/h
Delivery head: ........................................................................................... 12 barg

Hot well

1. Oil detector

Oil detection: ................................................................................................... Yes

Manuals

Language for manuals: .............................................................................. English


Sets of Approval Manuals: ..........................................................................15 sets
Sets of Working Manuals:...................................................................15 sets/ship
Sets of Instruction Manuals:.................................................7 sets/1st, 5 sets/other
CD-ROM documentation for Instruction Manuals:................................ 1 set/ship

QOS Release 5.5.54 Page 5/5