d&b R1 V3 Release notes

DOC05329 (01/2024) © d&b audiotechnik GmbH Co. KG


The R1 Remote control software Version 3 is designed to operate d&b
systems remotely using the d&b Remote network based on OCA (AES70)
via Ethernet technologies (D80, D40, D20, 40D, 30D, 10D, 5D, DN1,
DS100 and ArraySight) and CAN-Bus (D80, D20, 30D, 10D, D12, D6, E-
PAC with Display). A detailed description of the d&b Remote network and
CAN-Bus is given in the TI 312 d&b Remote network. An introduction to
Ethernet networks is given in the TI 310 Ethernet networking.

Recommended OS
Windows: Win 10 or higher
macOS (Intel): 10.14 or higher
macOS (M1/M2): 11.0 or higher

Note: Due to changes made by Apple, macOS 10.15 (Catalina) is the


last version that supports R60 as remote interface and allows D6 firmware
updates using direct USB connection.

Project file compatibility


To check whether your project will open in R1, please refer to the project
file compatibility table at the end of this document.

Installation hints
 If your firewall application blocks “mDNSResponder.exe”, please allow
access.

3.36.2

Features
 Support of DS100M added.

 Recalling Snapshots, recalling System settings or performing a device


redundancy sync operation is recorded as part of the R1 log.

www.dbaudio.com
Enhancements
 Dock for controlling sound object parameters and list of sound objects
improved by increasing the area for expanding / collapsing the docks.

Bug fixes
 DN1 and ArraySight are no longer part of the System settings dialog.
 Loading of project files when R1 is installed using a path containing
special characters on Windows fixed.
 Instead of showing 0.0 as value for level and delay, the 'Absolute
editing' tab of the Matrix crosspoint and Sound object routing controls
now displays the actual device value.
01/2024
3.34.1

Features
 En-Space custom rooms option added.
En-Space now provides three storage slots (Custom 1, Custom 2,
Custom 3) for individually recorded room responses.
The room response data can be added using the DS100 web interface
and recalled using R1. En-Space room measurements are a paid
d&b service.

 Event log export for 5D added.


The Event log tab now also allows exporting the visible information.

12/2023

www.dbaudio.com
3.32.3

Bug fixes
 Permanently lit GR / OVL indication fixed when T10 Line / Arc or 10AD
Line / Arc speakers are driven by a 5D amplifier and HFC is changed
to 0 while audio is played back.
 Switching off a 5D amplifier driving T10 Line / Arc or 10AD Line / Arc
speakers after changing HFC to 0 while audio was played back no
longer causes transients on output.
 When working on a project, the “The project file [...] was changed in
another program” notification no longer shows up for files that are part
of the 'Recent projects' list of ArrayCalc.
 “The project file [...] was changed in another program” notification no
longer shows up for project files saved to a folder being synchronized
using DropBox.
 When recalling an ArrayCalc snapshot, rel. Delay values of the
SUBarray are also properly restored.
 Importing ArrayProcessing data to R1 no longer fails when the
configuration of Non-ArrayProcessing loudspeakers is changed in
ArrayCalc.
 On Remote views, the sorting order of Snapshots, System settings and
Views has been corrected in the properties section of Controls.

 Selecting a sound object in the Sound objects list on Positioning views


now brings the selected item to the front.
10/2023

3.32.1

Features
 Event log for 5D added.

The Service view of R1 now provides an additional tab called 'Event


log' to read event information of 5D.
 Available firmware filtered according to device selection.
Selecting a device in the R1 Service view filters the firmware list for
simplified selection.

www.dbaudio.com
 Device Diagnostics tab shows error of individual channels.

 List of sound objects shown on positioning view

A list of all sound objects placed on the active positioning view is shown
in the upper left corner of the view. This list can be used for
selecting/highlighting a sound object.

Bug fixes
 Adding user defined templates containing pictures to R1 remote views
no longer loads the wrong picture.
 Applying EQ settings from previously exported EQ file to 5D now loads
all filters correctly.
 'En-Space room' selection now stored as part of System settings.
 Dock for controlling sound object parameters on positioning views no
longer randomly blocks keyboard input for Digital controls.
 Spread factor and Group delay controls within Function groups tab
show 'not loaded' state ( ) correctly when changing to Online mode
for the first time.
 'Manage & synchronize' window for synchronizing scenes does no
longer create duplicate entries when using device redundancy.
 MacOS: When using certain USB-C Ethernet adapters (powered by
ASIX AX88179A chipset), d&b devices are not found after re-plugging
the respective adapter.
A detection mechanism is added to identify those adapters.

08/2023

www.dbaudio.com
3.30.3

Bug fixes
 Minor performance improvements when creating System settings.
 ArrayProcessing slot name and comment correctly appearing on remote
views when loading a project.
 In Configuration mode, when scaling a positioning view, sound objects
no longer move beyond visible screen border.
05/2023

3.30.2

Bug fixes
 R1 no longer crashes when changing from Configuration to Tuning
mode with a project containing a Sound object remote control with no
target assigned.
 Device redundancy: Issue with adding or deleting a scene after
changing from online to offline and back to online now fixed.
 R70 interfaces are re-detected by R1 after network connection was lost.
02/2023

3.30.1

Features
 Dock for controlling sound object parameters on positioning views
added.

The dock can be expanded using the small arrow icon on the lower
right corner of a positioning view while R1 is in Tuning or Show mode.
If a sound object is selected, the dock allows instant access to sound
object parameters like delay mode, spread, En-Space send and others.
 System-wide notification of log events added.

When in Show mode, R1 uses the notifications functionality of the


operating system to inform about events taking place.
By default, notifications of errors and warnings will pop up for any
device that is part of your project. The applicable trigger level can be
adjusted using Application preferences.

www.dbaudio.com
 Support of E15X-SUB, T-SUB, xA line array and legacy loudspeakers
(E0, E3) on 5D added.
Bug fixes
 Copy & paste for multiselection (CTRL / CMD key) of settings in Matrix
crosspoint control fixed.
01/2023

3.28.2

Features
 Recalling Snapshots & System settings is no longer blocked.
The validation of Snapshots & System settings contents was removed.
Snapshots & System settings remain usable even if there is a change in
project configuration, device settings or firmware that would otherwise
lead to a failed validation.
Instead of blocking the recall function, R1 now validates settings when
transmitting Snapshots or System settings contents to the device. A
message is shown and an R1 log entry is created when an unsupported
setting is detected.
 This applies to situations where , for example, a Snapshot or System
setting is sending Load match settings to a device whose loudspeaker
configuration has changed and Load match is no longer supported by
the new loudspeakers.
 Selecting 5D loudspeaker setup possible in R1 Service view.

When starting R1 using the 'R1 V3 Inital device setup' Start menu entry
(introduced in R1 V3.26.1) you can now also select 5D loudspeaker
setups. This simplifies device installation even further.
Bug fixes
 Snapshots & System settings created with 40D / D40 firmware version
V1.00.04 or lower are no longer conflicted when using firmware
version V1.02.03 or higher.
After the removal of Snapshot & System setting validation (see above),
existing Snapshots & System settings can now be recalled.
The conflict was caused by a name change of the data object for the
AutoStandby threshold. The value of the outdated AutoStandby
threshold is no longer written to the amplifiers when recalling old
Snapshots or System settings.
Note:
It is highly recommended to store affected Snapshots & System Settings
again with the desired AutoStandby threshold value. For this particular
operation, the use of the “Store” function is mandatory to actually write
the new object name.

www.dbaudio.com
 Matrix input, output and crosspoint controls no longer show an endless
hour glass when using DS100 redundancy.
 Storing System settings of 10D and 30D updated to also include:
LED mode.
 Storing System settings of 40D and D40 updated to also include:
Mute on override.
 Storing System settings of 5D updated to also include:
LED mode, Mute on override, Input DT1/DT2/DT3/DT4, Dante input
gain, Dante input used for AutoStandby, GPI mode, GPI function, Input
fallback target, Input override source.
 Using Snapshot “Update” function now maintains relative control values
stored as part of the Snapshot.
12/2022

3.26.2

Bug fixes
 When DS100 is configured for redundancy, the individual properties in
the Devices view show the values of the device marked as 'read'.
09/2022

3.26.1
Notes
Starting from R1 version 3.26.x, macOS 10.12 is no longer supported.
With R1 version 3.30.x, available as from early 2023, the minimum system
requirements will be Windows 10 and macOS 10.14.

Features
 Support of 5D amplifier.
 Support of XSL-SUB.
 'Energy saving' tab for devices.
Existing 'AutoStandby' tab was renamed 'Energy saving'.
The redesigned tab now contains additional status information, such as
remaining time, etc. for 5D/10D/30D/40D/D20/D40/D80.

 Support of Eco mode for 40D/D40.


Option for controlling and monitoring Eco mode on
'Energy saving' tab added.

 Support of upcoming DS100 firmware version 2.


 Additional filter added to Service view to improve commissioning.
The newly added 'Initial device setup' filter provides a dedicated set of
device properties that are useful for setting up a device during the
commissioning phase of a project.
 New entry named 'R1 V3 Inital device setup' added in R1 start menu on
Windows.

www.dbaudio.com
The newly added start menu entry automatically launches R1 in online
mode and opens the Service view.

 Channel diagnostics tab now also contains 'LM impedance error'.


 Device diagnostics tab now also contains 'Input monitoring error'.

Bug fixes
 Speed of drag & drop operation used to add a template to a remote
view improved.
 A computer hosting R1 no longer freezes ,when using remote desktop.
 Occasional unusual high memory consumption when R1 is online fixed.
08/2022

3.22.6

Notes
To use the 'Improved loudspeaker position & orientation for Soundscape
projects' feature, Soundscape enabled projects must first be opened and
saved using ArrayCalc version 10.22.0 or higher.
Project files saved using the current R1 version 3.22.x cannot be opened in
older versions of R1 or ArrayCalc.

Bug fixes
 Issue with connections being lost occasionally when transmitting or
recalling scenes in DS100 fixed.
 DS100 Coordinate mapping name now instantly updated in the device
when changed in R1 while online.
 The draggable area of Sound object remote controls has been
increased to also include the surrounding gray ring.
07/2022

3.22.4

Notes
To use the 'Improved loudspeaker position & orientation for Soundscape
projects' feature, Soundscape enabled projects must first be opened and
saved using ArrayCalc version 10.22.0 or higher.
Project files saved using the current R1 version 3.22.x cannot be opened in
older versions of R1 or ArrayCalc.

Bug fixes
 R1 no longer crashes occasionally when loading a project file in which
devices were removed in ArrayCalc.
 Issue with changing the sorting order of Remote views fixed.
 Remote view sorting order in Home view is now maintained after
reopening a project.
 In the Devices view, the x and y values for DS100 En-Scene positions
are now correctly converted when units are set to 'feet'.
 Devices no longer get stuck in 'found but not connected' state ( )
despite correct network configuration.
05/2022

www.dbaudio.com
3.22.3

Notes
To use the 'Improved loudspeaker position & orientation for Soundscape
projects' feature Soundscape enabled projects must first be opened and
saved using ArrayCalc version 10.22.0 or higher.
Project files saved using the current R1 version 3.22.x cannot be opened in
older versions of R1 or ArrayCalc.

Bug fixes
 When enabling Device redundancy for DS100, the device will no
longer toggle between online and timeout for an indefinite period of
time.
 Controls on a remote view targeting a device or channel property allow
selecting a subfunction again.
03/2022

3.22.2

Notes
To use the 'Improved loudspeaker position & orientation for Soundscape
projects' feature Soundscape enabled projects must first be opened and
saved using ArrayCalc version 10.22.0 or higher.
Project files saved using the current R1 version 3.22.2 cannot be opened in
older versions of R1 or ArrayCalc.

Features
 Support of XSL(i)8 / XSL(i)12 on 30D amplifiers.
 Improved loudspeaker position & orientation for Soundscape projects.
The calculation of loudspeaker position & orientation for Soundscape
enabled projects was moved to ArrayCalc to obtain elaborated data.
This massively improves position & orientation data of monitors,
loudspeakers rotated vertically through more than ± 90° and
horizontal A-Series arrays.
 Device redundancy.
In the Device view of R1, two physical DS100 devices can be
configured to form one redundancy device .

Both, Device A and Device B, are treated as equal partners. Parameters


set in the (virtual) redundancy device in R1 are sent to both physical
devices provided both are connected.
When changes are made to one of the devices directly (e.g. using
OSC) or while one of the devices is powered off/in timeout, these
changes are not synchronized between the devices automatically.
Therefore a Sync option is provided to synchronize both physical
devices.
The controls and views of R1 only show values of either Device A or
Device B. You can define the device from which R1 should read by
tagging either A or B with a Read flag.
For more information, please refer to R1 Help contents.
 Device view update regarding DN1.
The Device view now provides extended information on DN1 Ethernet
ports on the General and Diagnostics tab.

www.dbaudio.com
 Improved dbRemID conflict dialog.
A conflict caused by multiple OCA devices using the same dbRemID
can now be solved from within R1. A dialog automatically pops up
when a conflict is detected. This dialog can be used to re-assign a
dbRemID to a device.

Bug fixes
 After changing a comment of a Device scene while online and having
the target device connected, the device now updates automatically.
 Remote controls readings of continuously updated device information
(e.g. level meters) do no longer get stuck showing the default value if
the firmware version of the device does not match the latest firmware
known to R1.
 Issue with Device conflict dialog (e.g. containing Model conflicts)
sometimes not closing automatically when error is resolved fixed.
Note: By updating DS100 Firmware to version 1.16.03 or higher
wrongly displayed 'not equal' status of Device scenes is fixed.
02/2022

3.20.2

Bug fixes
 Q1 back on track. Projects using Q1 speakers can now be loaded
again.
10/2021

3.20.1

Features
 Support of XSL(i)8 / XSL(i)12.
 Support of DN1 network switch.
 Support of D40 amplifier.
 Improved Input routing templates to follow D40 / 40D amplifier layout.
 Release notes of R1 now available in the R1 Help menu.

www.dbaudio.com
Bug fixes
 On Windows, the project lock (“Project file … is currently open...”-
warning) applied to a project file currently open in R1 is now removed
correctly when the system is shut down or restarted.
10/2021

3.18.5

Bug fixes
 AutoCreate improved to report less “Failed to find matching group tree”
warnings caused by DS100 configuration changes.
 Editing of nodes in Matrix crosspoint control blocked if Input uses
En-Scene mode and output is assigned to a function group.

Notes
On Windows, an automatic update of previous (< R1 version 3.16.0)
versions to R1 version 3.18.5 is not possible using the internal update
feature. Please download the latest version from www.dbaudio.com.
The Windows version of R1 version 3.18.5 is created for 64-bit operating
systems. This is the recommended version for all users.
If a 32-bit version of R1 is required, use R1 version 3.14.1, which can be
downloaded from the Software archive.
The Windows version of R1 version 3.18.5 no longer supports Peak-USB
and Peak-PCI CAN interfaces.
If a version of R1 is required which supports Peak-USB or Peak-PCI, use
R1 version 3.14.1, which can be downloaded from the Software archive.
08/2021

3.18.3

Bug fixes
 Deleting a venue element in ArrayCalc, which was used for coordinate
mapping in the DS100, no longer prevents R1 from loading the project.
 Remote items that display device information (Meter, LED, Display
controls) but address an adjustable device property are no longer
stored as part of a snapshot.
 Unintended “Project file changed” notification is no longer shown when
the project file is located on a OneDrive share on macOS.
 Digital input clock selection (Master / Slave / SRC) no longer shows
conflicted state when a D80 V2.22 or a D20 V2.14/16/18/20 is
used.
 When executing auto-creation, the project is marked as modified when
opened for the first time.
Notes
On Windows, an automatic update of previous (< R1 version 3.16.0)
versions to R1 version 3.18.3 is not possible using the internal update
feature. Please download the latest version from www.dbaudio.com.
The Windows version of R1 version 3.18.3 is created for 64-bit operating
systems. This is the recommended version for all users.
If a 32-bit version of R1 is required, use R1 version 3.14.1, which can be
downloaded from the Software archive.
The Windows version of R1 version 3.18.3 no longer supports Peak-USB
and Peak-PCI CAN interfaces.

www.dbaudio.com
If a version of R1 is required which supports Peak-USB or Peak-PCI, use
R1 version 3.14.1, which can be downloaded from the Software archive.
07/2021

3.18.2

Features
 Support of 40D amplifier.

Bug fixes
 'DS Data' Device details page no longer shows Input D1 & D2
information also for Input D3 & D4.
 EQ curve sometimes not shown for DS100 outputs fixed.

Notes
On Windows, an automatic update of previous (< R1 version 3.16.0)
versions to R1 version 3.18.1 is not possible using the internal update
feature. Please download the latest version from www.dbaudio.com.
The Windows version of R1 version 3.18.1 is created for 64-bit operating
systems. This is the recommended version for all users.
If a 32-bit version of R1 is required, use R1 version 3.14.1, which can be
downloaded from the Software archive.
The Windows version of R1 version 3.18.1 no longer supports Peak-USB
and Peak-PCI CAN interfaces.
If a version of R1 is required which supports Peak-USB or Peak-PCI, use
R1 version 3.14.1, which can be downloaded from the Software archive.
06/2021

3.16.3

Bug fixes
 Multiple DNS entries causing R1 to crash on Windows fixed.
 Support of ArrayCalc “flown install” mounting option added to
AutoCreate.
 Crash when toggling between Level metering modes of DS100 inputs
on Device view fixed.
 PRI and SEC LED on Device view no longer overlap “Rx label”
information when toggling between day and night modes.
 Sorting columns by name on “System check & ArrayVerification” view
fixed.

Notes
On Windows, an automatic update of previous (< R1 version 3.16.0)
versions to R1 version 3.16.3 is not possible using the internal update
feature. Please download the latest version from www.dbaudio.com.

www.dbaudio.com
The Windows version of R1 version 3.16.3 is created for 64-bit operating
systems. This is the recommended version for all users.
If a 32-bit version of R1 is required, use R1 version 3.14.1, which can be
downloaded from the Software archive.
The Windows version of R1 version 3.16.3 no longer supports Peak-USB
and Peak-PCI CAN interfaces.
If a version of R1 is required which supports Peak-USB or Peak-PCI, use
R1 version 3.14.1, which can be downloaded from the Software archive.
04/2021

3.16.2

Features
 Sound object routing control added to allow adjusting or muting each
En-Scene sound object within individual function groups.
upport of the two new function group modes 'Outfill embedded' and
'Delay line embedded' added.
 Precision of 'Spread' control step size reduced from 0.001 to 0.01.
 Support of 'Ready for R1' information provided by ArrayCalc added.

Bug fixes
 The enlarged EQ is no longer shown in the 'Snapshots & System
settings' view when creating snapshots.
 The DS100 Scenes 'Sync...' button is no longer blocked after loading a
new project without restarting R1.
 Crash when trying to add a template containing a picture fixed.
 Remote controls dealing with the delay value of an ArrayProcessing
enabled loudspeaker now use 6.2 ms as default value.
 Creating a group structure using AutoCreate no longer leads to a
warning popping up when loading the project.
 EQ curve of DS100 output channels occasionally not being visible on
first activation of the EQ tab fixed.
 OSC path reference on 'Coordinate mapping' tab corrected.
 When pasting remote items with no target assigned, an 'unassigned'
icon is displayed now.
Notes
On Windows, an automatic update of previous versions of R1 to R1
version 3.16.2 is not possible using the internal update feature. Please
download the latest version from www.dbaudio.com.
The Windows version of R1 version 3.16.2 is created for 64-bit operating
systems. This is the recommended version for all users.
If a 32-bit version of R1 is required, use R1 version 3.14.1, which can be
downloaded from the Software archive.
The Windows version of R1 version 3.16.2 no longer supports Peak-USB
and Peak-PCI CAN interfaces.
If a version of R1 is required which supports Peak-USB or Peak-PCI, use
R1 version 3.14.1, which can be downloaded from the Software archive.
02/2021

www.dbaudio.com
3.14.1

Features
 Support of 44S loudspeaker.

Bug fixes
 On macOS, R1 no longer crashes when editing remote control
properties after having moved the R1 application from one screen to
another.
 On Windows, R1 no longer crashes occasionally when opening a view
while having a touch screen installed or Windows 'Accessibility
Features' enabled.
 Duplicating a snapshot no longer shortens the new name in an
unforeseen manner when the original name ends with a number.
 When returning to an open positioning view, R1 now properly
remembers the area previously displayed.
 In tuning mode, controls are no longer hidden when clicking on a frame.
 Text control default size and color changed for more convenient
working.
10/2020
3.12.3

Bug fixes
 R1 no longer shows “The project file was changed in another program”
message when project file is saved in a shared OneDrive folder on
macOS.
 R1 no longer freezes randomly when changing the speaker setup.
 Picture control now differentiates between day and night modes.
 Moving or copying parts of the group tree no longer leads to a loss of
group contents.
 Typical impedance values for KSL-SUB added to the help contents.
 Check for updates settings (R1 Preferences > Updates) are now
properly taken into account .
 EQ 'Save as...' and 'Open...' dialogs no longer appear twice.
08/2020

3.12.2

Bug fixes
 Error in project password protection feature fixed, which could lead to
undesired behavior.
 R1 no longer crashes randomly when using DS100 Firmware V1.10.x.
 Discontinued firmware download with slow internet connection fixed
when download time exceeds 30 mins.
04/2020

3.12.1

Features
 Support of KSL-SUB loudspeaker.
 Improved compatibility with high resolution screens (including new
icons).
 'Device scenes' added to R1 to manage and control scenes within
DS100.

www.dbaudio.com
 Support of 'Ambient temperature' parameter control which was added
to DS100 to align signal delays with the actual speed of sound.
 Support of two new DS100 En-Space rooms: 'Theater – small' and
'Cathedral'.
 Support of 'Spread factor' parameter control for function groups, which
was added to DS100.
Notes
Support of KSL-SUB requires an update of D80 to firmware version 2.22.0
(or higher).
All DS100 related features require an update of DS100 to firmware
version 1.12.01 (or higher).

Bug fixes
 Missing Matrix input channel names added to 'En-Space – Inputs' tab.
 Editing of template names in Remote views enabled while in local edit
mode (R1 in Tuning mode, pencil activated on a specific view).
 Setting the first input/output number of a Matrix crosspoint control to a
higher value than the last input/output number no longer leads to
crosspoints indexes exceeding the maximum count of 64.
 Selecting multiple Channel controls with assigned targets no longer
leads to wrongly displaying << UNASSIGNED >> as target.
 Disconnecting and reconnecting the same device within a short period
of time no longer triggers a device conflict dialog pointing out that
multiple amplifiers use the same remote ID.
 THC and CPL for SL-Series control no longer change their positions
when enlarged to maximum using the mouse.
 Hourglass icon no longer shown on remote controls occasionally after
values have already been read.
 ArrayCalc venue element on positioning views no longer hidden by
pictures.
03/2020

3.10.1

Features
 Support of new CPL function for the SL-Series. Coupling for low and mid
frequencies can now be set separately (CPL low, CPL mid). Available for
all GSL and KSL setups (AP, Arc, Line).
 Support of new THC (Temperature & Humidity Control) function for all
array-processed setups providing temperature and humidity adjustment
without the need for recalculation in ArrayCalc.
Notes
Both the THC function and the new CPL function for the SL-Series require
the use of the latest version of ArrayCalc V10.10.0 (or higher) in
combination with the latest amplifier firmware V2.20.00 (or higher).
Existing project files based on an old ArrayCalc or R1 version can still be
used in combination with an old firmware. To use the new firmware
including the new functions with existing project files, ArrayProcessing data
must be recalculated using ArrayCalc and the R1 AutoCreate function
should be re-executed.

Bug fixes
 Unintended “The project file … was changed in another application”
message removed, shown when saving a project to a DropBox folder
on macOS.
 Grouped control sections for TOPs and SUBs created by AutoCreate no
longer overlap in the case of stacked arrays consisting of both.

www.dbaudio.com
 Hovering over a switch control in 'different values' state, which is
assigned to a group, no longer leads to a program crash.
12/2019

3.8.1

MacOS Information
This new R1 version 3.8.1 requires macOS 10.12 or higher. If you are
running macOS versions before 10.12, you can use R1 version 3.6.11
from our heritage software section. See link:
https://www.dbaudio.com/global/en/products/software/software-
archive/

Features
 Support of A-Series.'Same width' and 'Same height' tools added for
easy resizing of controls within remote views.
 Support of the improved En-Space initialization (Pre-Delay and
Mapping) of DS100 Firmware v1.10.01.
 Generate System settings with selected devices only.

Bug fixes
 Improved OCA connection handling (more robust against network
interruptions now).
 AutoCreate for 3xB2-SUB CSA SUB array configurations fixed.
 Scaling and rotation of joined venue elements is taken into account for
initialization of DS100.
 DS100 Soundscape initialization for SUB arrays and linked
loudspeakers now uses a calculated midpoint value.
10/2019
3.6.11

Bug fixes
 When recalling a snapshot containing relative fader positions, the
previously stored positions are recalled.
 Opening a project file located in a folder which is protected by
Windows 10 Defender “Controlled Folder Access” no longer leads to a
blocked R1 instance. Saving a project to a protected folder is only
possible when allowing access by using Windows 10 Defender
functionality.
07/2019

3.6.10

Bug fixes
 AutoCreate algorithm fixed when building 3 x B2-SUB CSA SUB array.
 Matrix crosspoint control popup no longer closed when clicking inside
input fields while zoom factor is higher than 100%.
 Matrix crosspoint control popup now accepts user input even if ISP
signal is flashing or TAB key was pressed.
 Network utilization improved while creating System settings. This results
in a reduced System settings creation time.
 R1 no longer crashes when recalling System settings with a lot of
content.

www.dbaudio.com
 Meter controls within automatically created DS100 'Input', 'Output' and
Soundscape 'En-Space zones & room' views redefined. Minimum and
maximum are now aligned with the fader control next to the meter
control. The marker position uses -2dbFS as default value.
 Meter controls within automatically created DS100 'Input' view updated
to use 'Matrix input level meter post fader' instead of 'Matrix input level
pre fader'.
 Snapshot recall with combined values for Input fallback/Input overwrite
mode and state does no longer cause random fallback/overwrite state.
06/2019

3.6.7

Features
 Support of B8-SUB loudspeaker.

Bug fixes
 “Digital input lock” property of D20/D80/10D/30D as target for
display controls added in R1 remote views.
 Display controls assigned to a group show a human readable content.
 Removing large group nodes no longer freezes R1.Matrix Crosspoint
control no longer allows modification of width and height parameters.
Instead, the actual width and height are calculated based on the input
& output count.
 “Highlight channels” button in Groups view checks for the type of
selection.
 Unexpected high CPU load while browsing Devices view fixed.
 Unintended “Project file changed” notification no longer shown if
project file is located on a network share, iCloud, DropBox,... on
MacOS.
 Check boxes in AutoCreate dialog now shown on MacOS Mojave.
 Switching views while an amplifier channel is selected in Devices view
re-enabled when using MacOS Mojave.
 Switching DS100 Coordinate mapping entries in Devices view re-
enabled in MacOS Mojave.
 Improved loading of a project file using double click on MacOS
Mojave.
04/2019

3.6.5

Bug fixes
 Setting of maximum number of speakers for KSL8-Arc, KSL8-Line,
KSL12-Arc and KSL12-Line setups in LoadMatch feature fixed.
 Inoperable device reset functionality re-enabled.
 DS100 Matrix Input / Matrix Output / En-Space Zone Eqs now show
the actual filters of the connected device.
 Matrix crosspoint control with hidden output controls no longer causes a
crash when clicking on an empty space within the crosspoints.
02/2019

www.dbaudio.com
3.6.3

Features
 Matrix crosspoint control improved.
 AutoCreate dialog improved.
 New En-Space room parameters 'Predelay factor' and 'Rear level'
support added. (Requires DS100 firmware v1.08.00 or higher).
 Meter, LED and display control size redefined.
Additional scale or way information will no longer affect the size of the
control element itself.

Note: This redefined control size may require small layout adjustments in
existing projects and templates.

Bug fixes
 Locking mechanism added to prevent accidental overwriting when
working with R1 & ArrayCalc on the same project at the same time.
(Requires ArrayCalc v10.6.0 or higher)
 Way information on meter controls no longer overlaps.
 No more unintended password prompt when opening a project created
using the Western Arabic numeric system on a computer that does not
use the same setting.
 Adding multiple sound object controls using 'Add to view' no longer
joins the items.

 Selecting a target in the remote control properties editor no longer


changes the target filter.
 Manually adding an online DS100 to project blocked to prevent
Soundscape parameter reset.
02/2019

3.4.4

Bug fixes
 AutoCreate now creates relative controls adding a “rel.” prefix to the
name.
 Copy & paste of a switch control targeting a snapshot no longer leads
to a checkable button.
 Issue with overlapping 2-Way active information for Meter controls
solved.
12/2018

3.4.3

Bug fixes
 Repositioning of controls using cursor keys or mouse improved on
Remote and Positioning views.
 Initial AutoCreate check no longer reports every source as outdated.
11/2018

3.4.2

Features
 Support of KSL loudspeakers.

www.dbaudio.com
 Support of symmetrical pair links provided by ArrayCalc.
Note: Enabling symmetrical pair linking in ArrayCalc will disable the
ArrayVerification function for the relevant source groups.
 Support of additional En-Space room #7 Modern – medium 2 (Bing
Concert Hall, Stanford)
 AutoCreate feature extended to include the creation of a group tree
and Remote views for DS100 / Soundscape.
 Size of meter and LED controls can now be reduced.

Bug fixes
 AutoCreate algorithm improved to support asymmetrical SUB arrays.
 AutoCreate algorithm improved to support flown & stacked arrays.
 AutoCreate algorithm caption for 'Digital input clock' fixed.
 AutoCreate is no longer triggered for projects configured to start in
Show mode.
 Column width of System check tables redefined to improve readability.
 Wrong drawing of sound object positions on Positioning views fixed
when these are based on rotated ArrayCalc venue elements.
 Sound object controls can now be moved to negative coordinates using
the keyboard.
 Opening a Positioning view in Tuning mode now shows the ArrayCalc
venue element with correct scaling.
 Changing the sorting order within the Snapshots & System settings view
now also applies to the list of snapshots and system settings.
 Aborting the snapshot update no longer removes the snapshot itself.
Matrix crosspoint control creation time decreased.
 Minor speed improvements when loading files with many snapshot or
system settings contents.
 Reoccurring 'Project file changed' dialog on MacOs no longer appears
when storing project locally.
10/2018

3.2.5

Bug fixes
 R1 load time accelerated, if harmed by many log entries.
 Fixed preview pictures of Remote & Positioning views if they failed to
appear.
 Removed graphical artifacts if resizing a Positioning view.
 Drawings of rotated Positioning views fixed.
 Modifications of picture controls do not lead to accidental resizing of
them any more.
07/2018

3.2.4

Bug fixes
 Crash caused when loading projects which are based on *.dbac2 files
and were modified by R1V2 fixed.
 Switching to Online mode sped up for projects containing large
amounts of snapshot contents.
 Wrong nominal position label of Array verification fixed.
 Adding / moving / scaling picture controls on Positioning & Remote
views sped up.
 Illogical restrictions when moving groups in group tree removed.

www.dbaudio.com
 Crash when loading the same template file containing pictures twice.
 AutoCreate now uses SUB array name specified in ArrayCalc.
 Positioning view scaling is no longer reset when switching to another
view while in Tuning mode.
 Analog/digital Input monitoring toggles for 10D/30D enabled in
Devices view.
07/2018

3.2.0

Features
 Log view added to display warnings and errors of devices that are part
of the project.
 Redesign of Sound object controls.
 Grid can be added to Positioning view.
 Picture control can be added to Positioning view.
 Sound object controls can be added to Positioning view using drag &
drop from the Matrix Input list on the left-hand side of the view.

Bug fixes
 ArrayVerification algorithm for T10 setup improved.
06/2018

3.0.11

Bug fixes
 Group tree validation after loading a project from ArrayCalc
added.“Audio networking” renamed “DS data” to avoid confusion with
the “Audio networking” option in ArrayCalc.
 System calibrate / check function no longer getting stuck.
 Missing channel controls after using Auto create fixed.
 Loss of relative control values in snapshots after using Update fixed.
 Remaining hourglass icon on “Digital clock selection” fixed.
05/2018

3.0.10

Bug fixes
 Fixed crash when switching to the Home view after editing Remote
control name.
 Fixed crash caused by undoing a join/split operation.
 Remote control template can now be properly assigned to a device
target.
Defining Remote control templates without a target fixed.
 Group targets can now be properly assigned to a selection of Remote
controls.
 Minor issues in Meter Remote control fixed.
04/2018

www.dbaudio.com
3.0.9

Bug fixes
 Missing option to assign mixed targets to templates fixed.
04/2018

3.0.8 Beta

Bug fixes
 Swapping Coordinate mapping working again after reloading project.
 Coordinate mapping tab contents now properly displayed.
Array verification no longer freezes.
 Issue with double-selected Sound object fixed.
 Correct scaling behavior in Positioning view.
 Group delay for Function groups correctly accepted now.
03/2018

3.0.7 Beta

Features
 System check extended to include testing the DS100 output routing.
 R1 Help now includes TI 501 d&b Soundscape.

Bug fixes
 Minor fixes for auto-creation of remote views.
 Channel name no longer lost when reopening the project.
 Selection in subfunction of DS subscribed channels function fixed.
 Copy&paste and drag&drop of a Matrix crosspoint control no longer
causes loss of target information.
02/2018

3.0.4 Beta

Bug fixes
 Increased overall stability.
 Support DS100 firmware prior to 1.00.06 removed. Please update
your device using the R1 Service view.
 Correct update of DS100 coordinate mapping after entering new
values while online.
 Issue with recalling & saving snapshots that contain Sound object
positions fixed.
12/2017

3.0.1 Beta

Features
 ArrayCalc V10 and R1 V3 include support for the new integrated
project file format (*.dbpr). This new project file format can be opened
and saved in both ArrayCalc and R1.
 Support of DS100 Signal Engine with new views for Input, Output and
matrix.

www.dbaudio.com
 Support of optional d&b Soundscape software features En-Scene and
En-Space.
 Extended Snapshot editor to view and delete content.

For a detailed description of the new features and information regarding


the recommended workflow, please also refer to the Software Newsletter.
12/2017

www.dbaudio.com
Project file compatibility
The following table lists the supported software versions required to
maintain project file compatibility.

Created in... Minimum version to open with...


ArrayCalc ArrayCalc R1 NoizCalc
11.4.x 11.4.x 3.36.x
4.0
11.2.x 11.2.x 3.34.x
3.32.x
11.0.x 11.0.x 3.30.x 3.2
10.26.x 10.26.x 3.26.x

10.24.x 3.0 Update 29.06.2022


10.24.x
10.22.x 3.22.x 2.8 Update 23.02.2022
10.22.x 10.22.x

Note:
In general, project files are upward compatible, i.e. later versions of an
application open project files created with previous versions of the same
application.

www.dbaudio.com

You might also like