New Product News

Miniture Circuit Breakers

BCL series - MCB's


For the protection purpose of distribution equipment in the residential or
similar facility.

■Features
• High qualified type in the line up
- 6kA standard breaking capacity
- 10kA high qualified breaking capacity capacity type in
addition to MCB line up.
• ON/OFF visual indicator
- Clarified a state of ON/OFF visually.
On: Red
Off: Green
• Instantaneous tripping characteristic
- B type: between 3 to 5 times of In
for small load such as lighting fixtures, BCL63E0BG-1P063 BCL63E0BG-3P063
appliances etc.
- C type: between 5 to 10 times of In
for general load such as Illumination,
fluorescent, inductive etc
- D type: between 10 to 20 times of In
for industry high inrush current load such as
motors, machines etc

■Specifications
Type BCL63E0 □ G BCL63H0 □ G
-1P □□□ -2P □□□ -3P □□□ -4P □□□ -1P □□□ -2P □□□ -3P □□□ -4P □□□
Appearance

Number of poles 1 2 3 4 1 2 3 4
Rated impulse withstand voltage 4.0 kV
(Uimp)
Rated insulation voltage (Ui) 500 V
Rated Current (In) 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63 A
Rated Voltage (Un) 1pole: 230/400V~
2, 3 and 4 pole: 400V~
Breaking Capacity (Icn) 6kA (=Ics) 10kA
Rated Frequency 50/60 Hz
Tripping Characteristic B type : 3 to 5 In, C type : 5 to 10 In, D type : 10 to 20 In
Electrical Endurance 8000 cycles
Mechanical Endurance 20,000 cycles
Calibration Temperature 30 °C
Operation Temperature -25 °C to 45 °C
Protection Degree IP20
Cable Termination Rigid Conductor 35mm2 Maximum
Flexible Conductor 25mm2 Maximum
Torque of Screw 2.5 N•m
Standard IEC/EN 60898-1

62D9-E-0276
62D1-E-0270
■Part number nomenclature
BCL 63 E0 B G - 1P 001
Basic type Rated current
Frame size 002 : 2 A 025 : 25 A
63 : 6AF 004 : 4 A 032 : 32 A
006 : 6 A 040 : 40 A
Icn type 010 : 10 A 050 : 50 A
E0 : 6 kA 016 : 16 A 063 : 63 A
H0 : 10 kA 020 : 20 A
Type of tripping curves Poles
B : B type 1P : 1 pole
C : C type 2P : 2 poles
D : D type 3P : 3 poles
Product category 4P : 4 poles
G : MCB

■Diamensions and tripping curves


BCL63E0□G (Icn=6kA)
1P 2P 3P 4P
50 18 36 54 72
35
45

85

73

BCL63H0□G (Icn=10kA)
1P 2P 3P 4P
50 18 36 54 72
35
45

85

73

5-7, Nihonbashi Odemma-cho, Chuo-ku, Tokyo, 103-0011, Japan


URL https://www.fujielectric.com/fcs/

Information in this catalog is subject to change without notice. 2021-5 PDF FOLS 62D9-E-0276