Owners Manual RAS-M10SKV RAS-M10SKCV RAS-M13SKV RAS-M13SKCV RAS-M16SKV RAS-M16SKCV
Owners Manual RAS-M10SKV RAS-M10SKCV RAS-M13SKV RAS-M13SKCV RAS-M16SKV RAS-M16SKCV
ENGLISH
ESPAÑOL
FRANÇAIS
ITALIANO
DEUTSCH
PORTUGUÊS
POLSKI
ČESKY
PУCСКИЙ
HRVATSKI
MAGYAR
TÜRKÇE
NEDERLANDS
ΕΛΛΗΝΙΚΑ
SVENSKA
SUOMI
NORSK
DANSK
ROMÂNĂ
% 3
• Do not insert your finger or any article into the air inlet/outlet. " Setup button (SET)
# 2 ~
WARNING • When an abnormality (burning smell, etc.) occurs, stop the air Clear button (CLR)
)
QUIET PURE
COMFORT
SLEEP
conditioner and disconnect the power supply or turn off the $ Memory and Preset button (PRESET)
+ &
breaker. % SWING FIX Hi-POWER ECO
One Touch button (ONE-TOUCH) (
6
• Do not wash the unit with water. It may cause an electric shock. & High power button (Hi-POWER)
7 #
• Do not use this air conditioner for other purposes such as ( Economy button (ECO) TIMER CLR
8 9
)
ON OFF
preserving food, breeding animal, etc. Quiet button (QUIET) ! SLEEP SET
"
• Do not step or put anything on the indoor/outdoor unit. It may ~ Comfort sleep button (COMFORT SLEEP) . -
CHK FILTER CLOCK
cause an injury or damage the unit. + Plasma Air Purifier button (PURE) ,
• Do not touch aluminium fin because it may cause an injury. (RAS-10, 13, 16SKVR-E Only)
CAUTION • Before cleaning the unit, turn off the main switch or the circuit , Filter reset button (FILTER)
breaker. - Clock Reset button (CLOCK)
• When the unit won’t be used for a long time, turn off the main . Check button (CHK)
switch or the circuit breaker.
• It is recommended that maintenance be performed by a specialist 5 ONE-TOUCH
when the unit has been operated for a long time.
Press the “ONE-TOUCH” button for fully automated operation that is customised
to the typical consumer preferences in your region of the world. The customised
1 INDOOR UNIT DISPLAY settings control temperature air flow strength, air flow direction and other settings
to provide you alternate contact with “ONE-TOUCH” of the button. If you prefer
Models: RAS-10, 13, 16SKV(R) Series, RAS-M10, 13, 16SK(C)V Series,
1 Hi POWER (Green) other settings you can select from the many other operating functions of your
4 5 2 FILTER (Orange) Toshiba unit.
ONE-TOUCH
3 PURE (Blue) (10, 13, 16SKVR-E Series)
Hi POWER FILTER PURE TIMER OPERATION 3 FAN-ONLY (Orange)
Press : Start the operation.
(M10, 13, 16SKCV-E Series)
1 2 3 3 PRE DEF (DE-FROST) (Orange) 6 AUTOMATIC OPERATION
RESET (13, 16SKV-E, M10, 13, 16SKV-E Series)
4 TIMER (Yellow)
6 5 OPERATION (Green) To automatically select cooling, heating, or fan only operation
MODE
6 RESET button
1. Press : Select A.
Models: RAS-10SKV-E
1. Remove the battery cover. 3. Press : Select AUTO, LOW , LOW+ , MED , MED+ , or
A
C
L
Press to start and stop plasma air purifier and air ionizer operation.
3 AIRFLOW DIRECTION The plasma air purifier and air ionizer can be activated or deactivated during air
conditioner is stopped and the air ionizer starts in conjunction with plasma air
purifier operation.
FIX
Note: The FILTER indicator (orange) turns on after PURE operation is performed
1 Press : Move the louver in the
desired vertical direction.
for about 1000 hours.
10 Hi-POWER OPERATION
To automatically control room temperature and airflow for faster cooling or heating
SWING operation (except in DRY and FAN ONLY mode)
2
Hi-POWER
Press : Swing the air Press : Start and stop the operation.
automatically and press again to stop.
11 ECO OPERATION
To automatically control room to save energy (except in DRY and FAN ONLY
For horizontal direction, adjust
3 manually.
mode)
ECO
Note: Note: Cooling operation; the set temperature will increase automatically 1 degree/
• Do not move the louver manually by others. hour for 2 hours (maximum 2 degrees increase). For heating operation the
• The louver may automation positioning by come operation mode. set temperature will decrease.
1 Press
ON
: Set the desired ON timer. Press
OFF
: Set the desired OFF timer. 20 SELF CLEANING OPERATION (COOL AND DRY OPERATION ONLY) EN
2 Press SET
: Set the timer. Press SET
: Set the timer. To protect bad smell caused by the humidity in the indoor unit.
1. If the button is pressed once during “Cool” or “Dry” mode, the fan will continue
3 Press CLR
: Cancel the timer. Press CLR
: Cancel the timer. to run for other 20 minutes, then it will turn off automatically. This will reduce the
Everyday timer allows the user to set both the ON & OFF timers and will be activated on a daily basis. moisture in the indoor unit.
2. To stop the unit immediately, press the 3 times within 30 seconds.
Setting Everyday Timer
Note:
• SELF CLEANING operation is default setting from factory.
1 Press
ON
: Set the ON timer. 3 Press
SET
. • To cancel this function, press and hold the reset button on the indoor unit for 20 seconds.
The SELF CLEANING operation will be cancelled. (5 beep sound but OPERATION
SET
lamp does not blink)
2 Press
OFF
: Set the OFF timer. 4 Press button during the ( or ) • Do the same to set this function again. (5 beep sound and OPERATION lamp
mark flashing. blink 5 time/sec for 5 seconds)
• AUTO RESTART operation will be cancelled by setting or cancellation of SELF
• During the every day timer is activating, both arrows ( , ) are indicated.
Note: CLEANING operation. Set it again if necessary.
• Keep the remote control in accessible transmission to the indoor unit;
otherwise, the time lag of up to 15 minutes will occur. 21 OPERATION AND PERFORMANCE
• The setting will be saved for the next same operation.
1. Three-minute protection feature: To prevent the unit from being activated for 3
minutes when suddenly restarted or switched to ON.
14 PRESET OPERATION 2. Preheating operation: Warm up the unit for 5 minutes before the heating operation starts.
Set your preferred operation for future use. The setting will be memorized by the 3. Warm air control: When the room temperature reaches the set temperature,
unit for future operation (except airflow direction). the fan speed is automatically reduced and the outdoor unit will stop.
1. Select your preferred operation. 4. Automatic defrosting: Fans will stop during defrost operation.
PRESET
5. Heating capacity: Heat is absorbed from outdoors and released into the room.
2. Press and hold for 3 seconds to memorize the setting. The P mark When the outdoor temperature is too low, use another recommended heating
displays. PRESET apparatus in combination with the air conditioner.
3. Press : Operate the preset operation. 6. Consideration for accumulated snow: Select the position for outdoor unit where it will
not be subjected to snow drifts, accumulation of leaves or other seasonal debris.
7. Some minor cracking sound may occur when unit operating. This is normal
15 AUTO RESTART OPERATION because the cracking sound may be caused by expansion/contraction of plastic.
To automatically restart the conditioner after the power failure (Power of the unit Note: Item 2 to 6 for Heating model
must be on.)
Air conditioner operating conditions
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to set the Outdoor Temperature
Temp. Room
operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5 seconds) 10, 13, 16SKVR-E
10SKV-E Temperature
Operation 13, 16SKV-E
• Do not operate ON timer and OFF timer.
2. Press and hold the RESET button on the indoor unit for 3 seconds to cancel the Heating –15°C ~ 24°C –10°C ~ 24°C Less than 28°C
operation. (3 beep sound but OPERATION lamp does not blink) Cooling –10°C ~ 46°C 15°C ~ 43°C 21°C ~ 32°C
Dry –10°C ~ 46°C 15°C ~ 43°C 17°C ~ 32°C
16 QUIET OPERATION Temp. Outdoor Temperature Room
To operate at super low fan speed for quiet operation (except in DRY mode) Operation M10, 13, 16SK(C)V-E Temperature
QUIET
Heating –15°C ~ 24°C Less than 28°C
Press : Start and stop the operation. Cooling 0°C ~ 43°C 21°C ~ 32°C
Note: Under certain conditions, QUIET operation may not provide adequate Dry 0°C ~ 43°C 21°C ~ 32°C
cooling or heating due to low sound features.
button on the remote control. 4. Press during pushing CHK ●. “B” will show on the display and “00”
Indoor Unit and Remote Control will disappear and the air conditioner will turn OFF. The Remote Control B is
• Clean the indoor unit and the remote control with a wet cloth when needed. memorized.
• No benzine, thinner, polishing powder or chemically-treated duster.
Cleaning the air ionizer (Once every six months) (RAS-10, 13, 16SKVR-E Only) Note: 1. Repeat above step to reset Remote Control to be A.
1. Turn off air conditioner using remote control and power supply. 2. Remote Control A has not “A” display.
2. Fully open the vertical air flow louvers by hand. 3. Default setting of Remote Control from factory is A.
3. Use a toothbrush to rub the ends of metal pin three or four times.
Note: Do not use cotton swabs or other objects with fluff.