Hi-MO ~
LRS-72HPH
53S~SSSM
■ Based on MIO wafer, best choice for ultra-large
power plants
■ Advanced module technology delivers superior
module efficiency
• MlO Gallium-doped Wafer • Smart Soldering • 9-busbar Half-cut Cell
■ Excellent outdoor power generation performance
■ High module quality ensures long-term reliability
12-year Warranty for
Materials and Processing
25-year Warranty for Extra
Linear Power Output
Complete System and
Product Certifications
IEC 61215, IEC 61730, UL 61730
ISO9001:2015: ISO Quality Management System
ISO14001: 2015: ISO Environment Management System
ISO45001: 2018: Occupational Health and Safety
IEC62941: Guideline far module design qualification and type approval
■
~
LONGI w ~ - CE
e us
Hi-MO ~ LRS-72HPH 535-SSSM
21.7%
MAXMODULE
0~3%
POWER
<2%
FIRSTYEAR
0.55%
YEAR225
HALF-CELL
•
EFFICIENCY TOLERANCE POWER DEGRADATION POWER DEGRADATION Lower operatmg temperature
Additional Value
25-Yea r Power Wa rranty
100%
98%
91.2%
87.7%
84.5%
80.7%
Units: mm~
2256
1400
990
400
Mechanical Parameters
Cell Orientation 144 (6X24)
Ju nction Box IP68, three diodes
4mm', +400, -200mm/±1400mm
Output Cable
length can be customized
Glass Single glass, 3.2mm coated tempered glass
Frame Anodized aluminum alloyframe
Weight 27.2kg
Dimension 2256Xll33X35mm
~
Tolerance:
Packaging 3lpcs per pallet/ 155pcs per 20' GP / 620pcs per 40' HC Length: ±2mm
Width: ±2mm
D A-A B-B
Electrical Characteristics STC: AMl.5 1000W/m2 25ºC NOCT: AMl.5 S00W/m' 20ºC lm/s Test uncertaintyfor Pmax: ±3%
ModuleType LR5-72HPH-535M LR5-72HPH-540M LRS-72H PH-545M LR5-72HPH-550M LR5-72HPH-555M
Testing Condition STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT
Maximum Power (Pmax/W) 535 399.9 540 403.6 545 407.4 550 411.1 555 414.8
Open CircuitVoltage (Voc/V) 49.35 46.40 49.50 46.54 49.65 46.68 49.80 46.82 49.95 46.97
Short Circuit Current (lsc/A) 13.78 11.14 13.85 11.20 13.92 11.25 13.98 11.31 14.04 11.35
Voltage at Maximum Power 0/mp/V) 41.50 38.55 41.65 38.69 41.80 38.83 41.95 38.97 42.10 39.11
Current at Maximum Power (lmp/A) 12.90 10.38 12.97 10.43 13.04 10.49 13.12 10.56 13.19 10.61
Module Efficiency(o/o) 20.9 21.1 21.3 21.5 21.7
Operating Parameters Mechanical Loading
Operational Temperature -40'C ~ +85'C Front Side Maximum Static Loading 5400Pa
Power Output Toleran ce 0~3% Rear Side Maximum Static Loading 2400Pa
Voc and lsc Tolerance ±3% Hailstone Test 25mm Hailstone atthe speed of23m/s
Maximum System Voltage DC1500V (1 EC/U L)
Maximum Series Fuse Rating 25A
Nominal Operating Cell Temperature 45±2'( Temperature Ratings (STC)
Protection Class Class 11 Temperature Coefficientof lsc +0.050%/'C
Ultype 1 or2 Temperature Coefficientof Voc -0.265%/'C
Fire Rating
IEC Class C Temperature Coefficientof Pmax -0.340%/'C
Specifications included in this datasheet
■ No.8369 Shangyuan Road, Xi'an Economic And are subject to change without notice.
LONGI Technological DevelopmentZone, Xi'an, Shaanxi, China.
Web: www.longi.com
LONGi reserves the right offinal
interpretation. (20230518Vl8)