Product data sheet 6GK5101-1BB00-2AA3

Product type designation SCALANCE X101-1

SCALANCE X101-1,
IE MEDIA CONVERTER UNMANAGED 1 X 10/100MBIT/S
RJ45 PORT,
1 X 100MBIT/S MULTIMODE BFOC,
LED DIAGNOSIS,
FAULT SIGNAL. CONTACT WITH SET BUTTON,
REDUNDANT POWER SUPPLY,
PROFINET COMPLIANT SLEEVE,
INCL. ELECTRONIC MANUAL ON CD

Transmission rate
•2 100 Mbit/s

Number of electrical/optical connections / for network components or 2


terminal equipment / maximum

Number of electrical connections

• for network components and terminal equipment 1

• for signaling contact 1

• for power supply 1

• for redundant power supply 1

Design of electrical connection

• for network components and terminal equipment RJ45 port

• for signaling contact 2-pole terminal block

• for power supply 5-pole terminal block

Number of optical interfaces / for optical waveguide

• at 100 Mbit/s 1

Design of optical interface / for optical waveguide

• at 100 Mbit/s BFOC-Port (Multimode up to 5 km)

Connectable optical power relative to 1 mW

• of the transmitter output

• minimum -19 dB

6GK5101-1BB00-2AA3 subject to modifications


Page 1/ 3 06/02/2014 © Copyright Siemens AG 2014
• maximum -14 dB

• of the receiver input / maximum -14 dB

Optical sensitivity relative to 1 mW / of the receiver input / minimum -31 dB

Attenuation / of fiber-optic cable transmission link / minimum 0 dB


necessary

Range / at the optical interface / depending on the optical fiber used

• minimum 0 km

• maximum 5 km

Operating voltage / of signaling contacts / at DC / rated value 24 V

Operating current / of signaling contacts / at DC / maximum 0.1 A

Type of / supply voltage DC

Supply voltage / external 24 V

• minimum 18 V

• maximum 32 V

Product component / fusing at power supply input Yes

Type of fusing / at input for supply voltage 0.5 A/60 V

Consumed current / maximum 0.12 A

Active power loss / at 24 V / for DC 3W

Ambient temperature

• during operating -10 … +60 °C

• during storage -40 … +80 °C

• during transport -40 … +80 °C

Relative humidity / at 25 °C / without condensation / during operating 95 %


/ maximum

Protection class IP IP30

Design Compact

Width 40 mm

Height 125 mm

Depth 124 mm

Net weight 0.55 kg

Mounting type

• 35 mm DIN rail mounting Yes

• wall mounting Yes

• S7-300 rail mounting Yes

Standard

• for EMC / from FM FM3611: Class 1, Divison 2, Group A, B, C, D / T.., Class 1, Zone 2,
Group IIC, T..

• for hazardous zone EN 600079-15 II 3 G EEx nA II T.. KEMA 06 ATEX 0021 X

• for safety / of CSA and UL UL 60950-1, CSA C22.2 No. 60950-1

• for hazardous area / of CSA and UL UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2
/ Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T..

6GK5101-1BB00-2AA3 subject to modifications


Page 2/ 3 06/02/2014 © Copyright Siemens AG 2014
• for emitted interference EN 61000-6-3

• for interference immunity EN 61000-6-4:2001

Verification of suitability EN 61000-6-2:2001, EN 61000-6-4:2001

• CE mark Yes

• C-Tick Yes

• KC approval Yes

Marine classification association

• American Bureau of Shipping Europe Ltd. (ABS) Yes

• Bureau Veritas (BV) Yes

• Det Norske Veritas (DNV) Yes

• Germanische Lloyd (GL) Yes

• Lloyds Register of Shipping (LRS) Yes

• Nippon Kaiji Kyokai (NK) Yes

• Polski Rejestr Statkow (PRS) No

Further Information / Internet Links


Internet-Link

• to website: Industry Mall http://www.siemens.com/industrial-controls/mall

• to website: Selector SIMATIC NET SELECTION TOOL http://www.siemens.com/snst

• to website: Industrial communication http://www.siemens.com/simatic-net

• to website: Information and Download Center http://www.siemens.com/automation/net/catalog

• to website: Image database http://automation.siemens.com/bilddb

• to website: CAx Download Manager http://www.siemens.com/cax

• to website: Industry Online Support http://support.automation.siemens.com

letzte Änderung: May 19, 2014

6GK5101-1BB00-2AA3 subject to modifications


Page 3/ 3 06/02/2014 © Copyright Siemens AG 2014

You might also like