Rope Socket Limar Braided Line R
Rope Socket Limar Braided Line R
Rope Socket Limar Braided Line R
Background:
On 14Aug 12:
Surface pull test R/socket to 4000Lbs.
Rih JDC pulling tool + Dummy R/socket + 1.50"x 2' Stem + RB pulling tool to latch Peak prong at 8788 RKB. Work jar up 15
times - no progress - fire oil jars 1800 lbs and pull tension 1 x 2000 lbs. Lost weight. Pooh - found cable slip out of R/socket.
Investigation:
- Found Limar Pear drop for braided line R/socket ID is 0.225” (stamped on body 0.250”). Incorrect pear drop for 7/32” wire.
- For our operation 0.250” Pear drop is used for ¼” wire, Not for 7/32” wire
- Checked stores, found all Limar Pear Drops have 6 segments. (Limar no longer supplies 8-segment pear drops).
Picture, from left hand side, pear drop for 7/32”, ¼”, 5/16” wire, all are 6-segments.
Planning:-
Before make up R/socket first check the ID of the Pear drop, also check for wear inside.
For ¼” wire
On top in picture for Pear drop for ¼” wire with 7/32” wire
On below in picture Pear drop for 7/32” wire with correct wire