MIN 7000-10000TL-X Quick Guide
1 . Overview
2.3 Communication module installation
Install Uninstall
▲Up Inverter side Inverter side
Inverter side Inverter side
1 2 3 4 5 6 7 8 9 10 11 12
(1)Front panel (2)Touch button (3)OLED screen (4)LED indicator (5)Mounting bracket
(6)Heat sink (7)DC switch (8)PV terminal (9)COM port (10)Vent valve 3 . Electrical connection
(11)USB port (12)AC terminal
Please prepare the cable before connecting as follows.
No. Cable name Type Recommend model
Note: Note:
1 Protective Single multi-core 6mm²
1.This document is for quick installation guidance only, please refer to User Manual for more details. grounding wire yellow-green wire 1.Please make sure all switches are in “OFF”
2.Growatt shall not be liable for any damage resulting from unproper installation. Two or three polychromatic position before wiring. For personal safety,
2 AC output wire 6mm² please do not operate with electricity.
multi-core copper wires
2.If the diameter of the cable does not match
3 PV input wire PV wire(such as PV1-F) 4mm ² - 6mm ² the terminal, or the cable is aluminum wire,
2 . Installation Communication please contact our after-sales personnel.
4 RS485 /
wire
System overview 2.1 Installation requirements
3.1 Grounding 3.2 AC output connection
≥300
42 5 180
≤15° 1 2
17 2 93 10 -12 m m L N PE
≥3 00 ≥3 0 0
≥3
392
00
182
233
3 4
≥50 0
Note:
Waterproof must
be blockedwith
unit:mm
fireproof mud to
prevent water.
2.2 Wall mounting
3.3 DC connection
3.3.1 PV input terminal installation
1 2 3
154
13
Positive metal terminal 8- 10mm
4mm ² - 6mm ²
4mm ² - 6mm ²
Negative metal terminal
Negative metal terminal
Please make sure the cable can not be Pull the PV cable make sure there
pulled out after pressing. is no loose or shaking.
4 5
Positive metal terminal
Note: Make sure the cable polarity is
correct and voltage is less than
1.When drilling holes in the wall, avoid water and electricity pipes, otherwise it may cause danger. 550V.
unit:mm Negative metal terminal
3.3.2 Plug in PV terminal
1 2 Note:
6. Power on and off steps
1.Before installing the PV terminal, please
PV+
double-check that the PV input voltage and Note:
current do not exceed the MPPT limits. Before turning the inverter on, please make sure the PV input voltage and current are within the MPPT limits.
2.When installing the PV terminal, pay Follow the steps below to turn the inverter on:
attention to the difference between the 1.Switch on the build-in DC isolator at the bottom of the inverter.
Click
positive and negative poles and the one-to- 2.Switch on the PV Array and DC isolator next to your inverter, if you can not find this switch, skip this step.
one correspondence between the terminals 3.Switch on the Solar AC isolator if the inverter is more than 3 meters away from your switchboard.
and the machine. 4.Switch on the solar supply main switch in the switch board.
3.There is a "click" sound when the terminal To shut down your system, follow this guide in reverse order.
PV- is connected,please gently pulling the PV
wire to make sure there is no loose or
pulling off. 7. Status of PV grid inverter
3.3.3 Communication cable installation
Customer can read more information by push button.
COM Port Pin Definitions (Type 2)
Symbol Description Explanation
No. Description Remarks
Switch the display interface or the
Dry contact : external Single touch
1 +12V current number plus 1
relay coil interface,
power is not more than Double touch Enter the setting state or confirm
2 COM 2W Touch button Return to the previous display
Triple touch
3 RS485A1 RS485 communication interface
4 RS485B1 port The current data returns to the
Hold 5s
default value
7 RS485B2 Meter communication
Type 1 Type 2 Type 3 Red Fault
8 RS485A2 port
COM Port Pin Definitions (Type 2&3) Green Normal operation
9 DRM1/5 /
Inverter status indicator Red light flashing Warning
No. Definition No. Definition 10 DRM2/6 /
1 RS485A1 3 RS485A2 It can display the basic information of inverter through OLED display
11 DRM3/7 / screen (PV/AC voltage,PV power,AC current,total power,generating
Signal for communication Signal for Smart Meter
2 RS485B1 4 RS485B2 capacity, etc.).
12 DRM4/8 /
Note: 13 REF/GEN GND
8. Export limitation setting
There are three type signal connectors for different country.
14 DRM0/COM /
15 CT-P White Export limit Limit Rate
Set parameter
16 CT-N Black or Blue OFF ON XXX.X%
If the local grid company requires to limit the output power
from your inverter systems,we introduce the concept of
Export Limit Rate.The ratio of your system output power
General Meter divided by the rated power of the inverter is called Export
4. Connecting Meter
Advanced CT
Set OK Limited Rate.For example,if the local grid companyonly
accepts 8kW from your 10kW system,then the Export Limit
The following table describes how we can connect EASTRON meter (SDM120CT(40mA)to inverter: Rate of 10kW inverter should be 80%.
Meter Pin NO. Description Meter Connection
Password Control type
L L 1 CT-P(White) *** SW HW Both
CT-input
N N 2 CT-N(Black or Blue)
COM 1
3 N-in Grid N
485A2 485B2 9. Service and contact
4 L-in Grid L
LOAD 9 RS485B Shenzhen Growatt New Energy Co., Ltd
COM Port RS485B2
4-13/F,Building A,Sino-German(Europe) Industrial Park,
10 RS485A COM Port RS485A2 Hangcheng Ave,Bao’an District,Shenzhen,China
T +86 0755 2747 1942
Note: 1 For Australian market,installers can connect pin3 to the
neutral links/bars. E
[email protected] W www.ginverter.com
5. Post-installation check
No. Acceptance criteria No. Acceptance criteria
1 The inverter is installed correctly, firmly and reliably. 6 The RS485 communication cable is installed correctly and firmly.
The ground wire connected well and the connection is firm The cable tie port is trimmed well without leaving sharp
2 7
and reliable. corners,meets the requirements of the user.
All exposed terminals are well protected and there are no vacant Download
3 All switches are in the OFF state. 8 Growatt New Energy
ports. Manual
4 All wiring is correct and securely connected. 9 Pay attention to clean up all construction residues.
The wiring of the cable is reasonable, meets the
5
requirements, and there is no phenomenon of broken skin. GR-UM-224-A-01