Version 7.4.

PVsyst TRIAL
PVsyst - Simulation report
Grid-Connected System

Project: instalation on grid aoulouz


Variant: Nouvelle variante de simulation
No 3D scene defined, no shadings
System power: 110 kWp

PVsyst TRIAL Bou Safarn - Maroc

PVsyst TRIAL

PVsyst TRIAL
Author

PVsyst TRIAL
Project: instalation on grid aoulouz
Variant: Nouvelle variante de simulation

PVsyst V7.4.1
VC0, Simulation date:
29/08/23 16:55

PVsyst TRIAL
with v7.4.1

Project summary
Geographical Site Situation Project settings
Bou Safarn Latitude 30.67 °N Albedo 0.20
Maroc Longitude -8.15 °W
Altitude 768 m
Time zone UTC

Meteo data
Bou Safarn
PVGIS api TMY

System summary

PVsyst TRIAL
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation Near Shadings User's needs


Fixed plane No Shadings Unlimited load (grid)
Tilt/Azimuth 30 / 0 °

System information
PV Array Inverters
Nb. of modules 200 units Nb. of units 1 unit
Pnom total 110 kWp Pnom total 110 kWac
Pnom ratio 1.000

Results summary
Produced Energy 223038 kWh/year Specific production 2028 kWh/kWp/year Perf. Ratio PR 85.30 %

PVsyst TRIAL
Project and results summary

Main results
Loss diagram
Predef. graphs
Table of contents

General parameters, PV Array Characteristics, System losses


2
3
4
5
6

PVsyst TRIAL

PVsyst TRIAL
29/08/23 PVsyst Evaluation mode Page 2/6
Project: instalation on grid aoulouz
Variant: Nouvelle variante de simulation

PVsyst V7.4.1
VC0, Simulation date:
29/08/23 16:55

PVsyst TRIAL
with v7.4.1

General parameters
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / 0 ° Diffuse Imported
Circumsolar separate

Horizon Near Shadings User's needs


Free Horizon No Shadings Unlimited load (grid)

PVsyst TRIAL
PV Array Characteristics
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model LR5-72HPH-550M G2 Model SUN2000-110KTL-M0
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 550 Wp Unit Nom. Power 110 kWac
Number of PV modules 200 units Number of inverters 10 * MPPT 10% 1 unit
Nominal (STC) 110 kWp Total power 110 kWac
Modules 10 Strings x 20 In series Operating voltage 200-1000 V
At operating cond. (50°C) Max. power (=>30°C) 121 kWac
Pmpp 101 kWp Pnom ratio (DC:AC) 1.00
U mpp 756 V No power sharing between MPPTs
I mpp 133 A

PVsyst TRIAL
Total PV power Total inverter power
Nominal (STC) 110 kWp Total power 110 kWac
Total 200 modules Number of inverters 1 unit
Module area 517 m² Pnom ratio 1.00
Cell area 480 m²

Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 94 mΩ Loss Fraction -0.8 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module mismatch losses


Loss Fraction 2.0 % at MPP

PVsyst TRIAL
IAM loss factor
Incidence effect (IAM): User defined profile

0° 25° 45° 60° 65° 70° 75° 80° 90°


1.000 1.000 0.995 0.962 0.936 0.903 0.851 0.754 0.000

PVsyst TRIAL
29/08/23 PVsyst Evaluation mode Page 3/6
Project: instalation on grid aoulouz
Variant: Nouvelle variante de simulation

PVsyst V7.4.1
VC0, Simulation date:
29/08/23 16:55

PVsyst TRIAL
with v7.4.1

Main results
System Production
Produced Energy 223038 kWh/year Specific production 2028 kWh/kWp/year
Perf. Ratio PR 85.30 %

Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray


kWh/m² kWh/m² °C kWh/m² kWh/m² kWh
January 114.3 27.80 10.26 176.2 173.8 17509

PVsyst TRIAL
February 144.5 28.84 8.89 199.5 197.0 19752
March 165.2 55.17 13.74 190.3 187.3 18476
April 184.5 53.92 17.48 190.0 186.4 18070
May 244.4 60.36 20.57 228.1 223.4 21463
June 222.6 65.04 26.18 198.9 194.5 18371
July 244.3 69.60 26.74 224.3 219.6 20647
August 199.1 66.70 28.20 197.6 193.9 18145
September 191.1 51.51 22.97 215.3 211.9 20055
October 152.2 46.56 18.61 194.7 191.9 18673
November 112.6 39.55 12.17 161.9 159.7 16088
December 121.3 23.91 11.03 200.1 197.6 19815
Year 2096.1 588.94 18.13 2376.9 2337.0 227064

PVsyst TRIAL
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation
T_Amb Ambient Temperature
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings

PVsyst TRIAL
29/08/23 PVsyst Evaluation mode Page 4/6
Project: instalation on grid aoulouz
Variant: Nouvelle variante de simulation

PVsyst V7.4.1
VC0, Simulation date:
29/08/23 16:55

PVsyst TRIAL
with v7.4.1

Loss diagram
2096 kWh/m² Global horizontal irradiation
+13.4% Global incident in coll. plane

-1.68% IAM factor on global

2337 kWh/m² * 517 m² coll. Effective irradiation on collectors

efficiency at STC = 21.32% PV conversion

257448 kWh Array nominal energy (at STC effic.)

PVsyst TRIAL
-0.56% PV loss due to irradiance level

-9.00% PV loss due to temperature

+0.75% Module quality loss

-2.00% Module array mismatch loss

-1.28% Ohmic wiring loss


227064 kWh Array virtual energy at MPP
-1.77% Inverter Loss during operation (efficiency)
0.00% Inverter Loss over nominal inv. power
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage

PVsyst TRIAL
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
-0.01% Night consumption
223038 kWh Available Energy at Inverter Output
223038 kWh Energy injected into grid

PVsyst TRIAL

PVsyst TRIAL
29/08/23 PVsyst Evaluation mode Page 5/6
Project: instalation on grid aoulouz
Variant: Nouvelle variante de simulation

PVsyst V7.4.1
VC0, Simulation date:
29/08/23 16:55

PVsyst TRIAL
with v7.4.1

Predef. graphs
Diagramme d'entrée/sortie journalier

PVsyst TRIAL

PVsyst TRIAL Distribution de la puissance de sortie système

PVsyst TRIAL

PVsyst TRIAL
29/08/23 PVsyst Evaluation mode Page 6/6