AVENAR - Panel - 8000 Quick Guide
AVENAR - Panel - 8000 Quick Guide
Panel overview Y Power fault What to do in case of an alarm Alarm verif. Detector 00006-002
#001 Office 1 - first floor (1)
Status LEDs 1 3
Caution! G Power available
Alarm verif. Detector 00006-002
Do not use any pointed or sharp objects when Color* Meaning
! operating the touch-sensitive display. The touch-
#001 Office 1 - first floor (1)
R Fire alarm Y System/panel fault
screen must not be exposed to direct sunlight. 5 2 4
Time to investigate 00:30 min
2
* Level 3 logged in
11 R Evacuation ongoing G System in operation
Bypass
Diagnostics 1 2 3
Time to acknowledge 00:30 min
Block
ABC DEF
Reset Manual alarm
4 5 6
Maintenance Configuration GHI
7
JKL
8
MNO
1 Status LEDs 6 Display a list of the networked 3 Address (logical zone and subaddress) of the detector If you recognize a false alarm, select Reset and log in to
Y General disabled
panels and establish a remote which triggered the alarm the panel to prevent the activation of the transmission
connection with a networked 4 Number of detectors which triggered the alarm device and signaling devices.
Y General fault
panel Note: If the investigation time passes by without any fur-
5 Message number
2 Information bar 7 Display and control all alarm Y** Fire detector fault / disabled ther user input (alarm trigger or reset) the evacuation and
6 Number of groups that have triggered a fire alarm and
zones the transmission to the fire department are activated auto-
Y** Signaling device fault / disabled outputs that are activated
3 Status bar 8 Log-in to the panel and call up matically.
Select Acknowledge to start the investigation time (de-
personalized menu pending on the configuration). During this time, check the
Y** Alarm transmission device fault / disabled
4 Open start menu 9 Silence internal buzzer message in the place where the detector generating the
5 Go back 10 Function keys, programmable Y** Output to fire protection equipment fault / alarm is located to ensure it is correct.
6| 7| 8| 9| 10 |
Evacuation The background colors of the groups have the following Resetting an alarm What to do in case of a fault
meaning:
* Level 3 logged in
Fire Detector 00006 1 2 3
Bypass
Diagnostics
– Red: Groups which are actively being controlled in #001 AV - day mode enabled. (1)
Block 1 2 3
4
ABC
5
DEF
6
case of an alarm Fault Detector 00006-002
Maintenance Configuration GHI JKL MNO
7 8 9 – Fuchsia: Groups which are actively being controlled #001 Office 1 (1)
PQRS TUV WXYZ
Switch to day mode Further functions
* 0 # without a real alarm, e.g. in case of a fire drill
– Green: Groups which are not active 4 5 6
Control Reset Name Telephone number
Monitoring
– Yellow: Groups in fault or disabled, no control is pos-
2 2 0 0
Status
sible. 1 Message type
Fire Control Fault Bypass F1 F2 F3 1 2 3
Evacuation
2 Element type (corresponding to the second yellow fault Log on and log off
i Enter number for NAC! Acknowledge Signals off Signals on Reset status LED)
All All Log-in
27 On Off
3 Address (logical zone and subaddress) of the element
2 2 0 0
Press the evacuation button to open the list with all avail-
27 28 Fire Control Fault Bypass
Status which triggered the fault i Enter password!
able evacuation zones.
NAC group on module 27/1 NAC group on module 27/2
1. Press Acknowledge. 4 Message number UserID:
To search for a specific zone, enter the number of a group 2
29 30 2. Press Signals off. 5 Description of the location of the triggering element
NAC group on module 28/1 NAC group on module 28/2 The sounders and/or optical signaling devices are 6 Number of elements which triggered the fault
of notification appliances and press .
switched off. Password:
Evacuation
31 32 In case that the panel is showing a fault message with yel-
3. Press Reset.
NAC group on module 29/1 NAC group on module 29/2 low background in combination with a yellow shining
i Enter number for NAC!
All All
27 On Off Fire Detector 00006-002 OK Cancel
2
Fire
1
Control
0
Fault
0
Bypass
Status #001 Office 1 (1) R LED and the fault LED , , , ,
27 28 0 0 0 0
Select the required group to start or stop the evacuation If a message is marked with an R, the resetting process is Fire Control Fault Bypass
Status
NAC group on module 27/1 NAC group on module 27/2
or corresponding to the element type (2) in the
not yet complete for this element. fault message:
29 30
of this zone immediately. Use and to
NAC group on module 28/1 NAC group on module 28/2
To reset a manual call point, use the reset key or replace 1. Press Acknowledge to silence the buzzer
scroll through the list. The group entries change their
the glass window. 2. Press Reset.
31 32 background color according to their current state.
NAC group on module 29/1 NAC group on module 29/2
To reset an automatic detector: If there is still smoke in 3. If the fault cannot be reset, please call your installer:
Select All On to control all evacuation groups or All Off to
the detection chamber please ventilate. Press to log on to the panel with your user
stop the activation of all groups at a time.
2 1 0 0 On the next alarm message, all signaling devices that have ID and password. Depending on your access authorization
Status
Fire Control Fault Bypass level (2-4), you can use only particular functions.
been switched off are switched back on automatically.
11 | 12 | 13 | 14 |
The default password is “000000”, please ask your in- Programmable elements Change time and date Standalone Network
staller to change this password. To change the date and time of the panel press
Function keys Night mode Panel is in All networked panels
Note: The panel controller may only be operated by night mode in the network scope AVENAR panel 8000 | AVENAR panel 2000 |
There are three functions keys which are freely program-
trained personnel. The personal access code (consisting - Further functions - Change date / time and are in night mode AVENAR keypad 8000
mable with frequently used functions of the panel. If a
of user ID and password) must not be made known to enter the correct values via the keypad.
function key is active it is marked with a green bar. Please Day mode Panel is in - FPE‑8000‑SPC | FPE‑8000‑PPC | FPE‑8000‑FMR |
third parties.
ask your installer to enter the configured function of the Day- and night mode day mode FPE‑2000‑SPC | FPE‑2000‑PPC
* Favourites respective key here: The manner in which an incoming alarm is handled de- Night-/day - Panel is in night
1 2 3 pends on whether the system is in day or night mode. combination mode but at least
Bypass off Bypass off
ABC DEF
Multicriteria sensor Multicriteria sensor
4
GHI
5
JKL
6
MNO
F1 Night mode has the highest security level. Depending on one other panel in
Bypass off Bypass off the configuration, the alarm message is generally transmit- the network scope is
Multicriteria sensor 7 8 9
Multicriteria sensor PQRS TUV WXYZ
ted to the fire department without a delay. Signaling in daymode
* 0 #
Bypass on
Red strobe
Bypass off
Red strobe
F2 devices and transmission devices to the fire department or To switch between day- and night mode press the current
fire protection systems are activated. symbol in the status bar and select either Switch to day
If a panel is set to day mode, it is possible to delay the mode or Switch to night mode.
0 0 0 0
Status F1 F2 F3
F3 transmission of the first alarm signal to prevent false
Fire Control Fault Bypass
alarms. Therefore an alarm must be acknowledged within 0 0 0 0
Status
a certain time. The transmission device to the fire depart- Fire Control Fault Bypass
Alarm and fault status LEDs ment is not activated in this case. During the delay, the
There are two status LEDs which are programmable for a cause of the alarm message can be checked within a con-
self-defined alarm and self-defined fault/disablement. figured investigation time to ensure it is correct.
Please ask your installer to describe the configured device If the investigation time passes by without any further user
If you are already logged on, press to open
and status of the respective LED here: input (alarm trigger or reset) the transmission to the fire
the pre-configured personalized menu. To log off, press
department is activated automatically. en Quick user guide
again and confirm with OK . The following symbols on the status bar show which mode
the panel is switched to. In the case of networked panels,
a night-/day combination icon is displayed on panels in
night mode, if at least one panel in the network is in day
mode.
15 | 16 | 17 | 18 |
Switching off internal buzzer Further information
* Level 3 logged in For detailed information on the operation of the fire panel
Bypass
Diagnostics 1 2 3
please refer to www.boschsecurity.com.
Block
ABC DEF
4 5 6
Maintenance Configuration GHI JKL MNO
7 8 9
PQRS TUV WXYZ
Control Reset
Monitoring
2 2 0 0
Fire Control Fault Bypass
Status F1 F2 F3
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
www.boschsecurity.com
© Bosch Sicherheitssysteme GmbH, 2020
Display history
In the history log, all data about particular events or
device types is stored sorted by date and time. To display
only particular data, filters can be set.
Select language