Canatuan ME Lab. 3 Exercise 1 Statistical Process Control
Canatuan ME Lab. 3 Exercise 1 Statistical Process Control
Process Variability
If you have reviewed the discussion of frequency distributions in the Histogram module, you will recall that many histograms
will approximate a Normal Distribution, as shown below (please note that control charts do not require normally
distributed data in order to work - they will work with any process distribution - we use a normal distribution in this
example for ease of representation):
In order to work with any distribution, it is important to have a measure of the data dispersion, or spread. This can be expressed
by the range (highest less lowest), but is better captured by the standard deviation (sigma). The standard deviation can be
easily calculated from a group of numbers using many calculators, or a spreadsheet or statistics program.
Example
• If you put one foot in a bucket of ice water (33 degrees F) and one foot in a bucket of scalding water (127 degrees F), on
average you'll feel fine (80 degrees F), but you won't actually be very comfortable!
• If you are asked to walk through a river and are told that the average water depth is 3 feet you might want more information.
If you are then told that the range is from zero to 15 feet, you might want to re-evaluate the trip.
MoreSteam Hint: Analysis of averages should always be accompanied by analysis of the variability!
Control Limits
Statistical tables have been developed for various types of distributions that quantify the area under the curve for a given
number of standard deviations from the mean (the normal distribution is shown in this example). These can be used as
probability tables to calculate the odds that a given value (measurement) is part of the same group of data used to construct
the histogram.
Shewhart found that control limits placed at three standard deviations from the mean in either direction provide an economical
tradeoff between the risk of reacting to a false signal and the risk of not reacting to a true signal - regardless the shape of the
underlying process distribution.
If the process has a normal distribution, 99.7% of the population is captured by the curve at three standard deviations from
the mean. Stated another way, there is only a 1-99.7%, or 0.3% chance of finding a value beyond 3 standard deviations.
Therefore, a measurement value beyond 3 standard deviations indicates that the process has either shifted or become unstable
(more variability).
The illustration below shows a normal curve for a distribution with a mean of 69, a mean less 3 standard deviations value of
63.4, and a mean plus 3 standard deviations value of 74.6. Values, or measurements, less than 63.4 or greater than 74.6 are
extremely unlikely. These laws of probability are the foundation of the control chart.
Now, consider that the distribution is turned sideways, and the lines denoting the mean and ± 3 standard deviations are
extended. This construction forms the basis of the Control chart. Time series data plotted on this chart can be compared to the
lines, which now become control limits for the process. Comparing the plot points to the control limits allows a simple probability
assessment.
We know from our previous discussion that a point plotted above the upper control limit has a very low probability of coming
from the same population that was used to construct the chart - this indicates that there is a Special Cause - a source of
variation beyond the normal chance variation of the process.
Statistical Process Control is based on the analysis of data, so the first step is to decide what data to collect. There are two
categories of control chart distinguished by the type of data used: Variable or Attribute.
Variable data comes from measurements on a continuous scale, such as: temperature, time, distance, weight. Attribute data
is based on upon discrete distinctions such as good/bad, percentage defective, or number defective per hundred.
MoreSteam Hint: Use variable data whenever possible because it imparts a higher quality of information - it does not rely on
sometimes arbitrary distinctions between good and bad.
A critical but often overlooked step in the process is to qualify the measurement system. No measurement system is without
measurement error. If that error exceeds an acceptable level, the data cannot be acted upon reliably. For example: a Midwest
building products manufacturer found that many important measurements of its most critical processes had error in excess of
200% of the process tolerance. Using this erroneous data, the process was often adjusted in the wrong direction - adding to
instability rather than reducing variability. See the Measurement Systems Analysis section of the Toolbox for additional help
with this subject.
Develop a sampling plan to collect data (subgroups) in a random fashion at a determined frequency. Be sure to train the data
collectors in proper measurement and charting techniques. Establish subgroups following a rational subgrouping strategy so
that process variation is captured BETWEEN subgroups rather than WITHIN subgroups. If process variation (e.g. from two
different shifts) is captured within one subgroup, the resulting control limits will be wider, and the chart will be insensitive to
process shifts.
The type of chart used will be dependent upon the type of data collected as well as the subgroup size, as shown by the table
below. A bar, or line, above a letter denotes the average value for that subgroup. Likewise, a double bar denotes an average
of averages.
Consider the example of two subgroups, each with 5 observations. The first subgroup's values are: 3,4,5,4,4 - yielding a
subgroup average of 4 (x̄1). The second subgroup has the following values: 5,4,5,6,5 - yielding an average of 5 (x̄2). The
average of the two subgroup averages is (4 + 5)/2 = 4.5, which is called X double-bar (̿x), because it is the average of the
averages.
You can see examples of charts in Section 9 on Control Limits.
MoreSteam Note: Specifications should NEVER be expressed as lines on control charts because the plot point is an average,
not an individual. The only exception is the moving range chart, which is based on a subgroup size of one.
Consider the case of a subgroup of three data points: 13, 15, 17. Suppose the upper specification limit is 16. The average of
the subgroup is only 15, so the plot point looks like it is within the specification, even though one of the measurements was
out of spec.! However, specifications should be printed on the side, top, or bottom of the chart for comparing individual
readings.
8. Add Chart to Control Plan
A control plan should be maintained that contains all pertinent information on each chart that is maintained, including:
• Chart Type
• Chart Champion - Person(s) responsible to collect and chart the data
• Chart Location
• Measurement Method
• >Measurement System Analysis (Acceptable Error?)
• Reaction Plan
• Gauge Number - Tied in with calibration program
• Sampling Plan
• Process Stability Status
• Cp & Cpk
The control plan can be modified to fit local needs. A template can be accessed through the Control Plan section of the Toolbox.
Terms used in the various control chart formulas are summarized by the table below:
1. If one or more points falls outside of the upper control limit (UCL), or lower control limit (LCL). The UCL and LCL are
three standard deviations on either side of the mean - see section A of the illustration below.
2. If two out of three successive points fall in the area that is beyond two standard deviations from the mean, either above
or below - see section B of the illustration below.
3. If four out of five successive points fall in the area that is beyond one standard deviation from the mean, either above
or below - see section C of the illustration below.
4. If there is a run of six or more points that are all either successively higher or successively lower - see section D of the
illustration below.
5. If eight or more points fall on either side of the mean (some organization use 7 points, some 9) - see section E of the
illustration below.
6. If 15 points in a row fall within the area on either side of the mean that is one standard deviation from the mean - see
section F of the illustration below.
When an out-of-control condition occurs, the points should be circled on the chart, and the reaction plan should be followed.
When corrective action is successful, make a note on the chart to explain what happened.
More Steam Hint: Control charts offer a powerful medium for communication. Process shifts, out-of-control conditions, and
corrective actions should be noted on the chart to help connect cause and effect in the minds of all who use the chart. The
best charts are often the most cluttered with notes!
11. & 12. Analyze Data to Identify Root Cause and Correct
If an out-of-control condition is noted, the next step is to collect and analyze data to identify the root cause. Several tools are
available through the MoreSteam.com Toolbox function to assist this effort - see the Toolbox Home Page. You can use
MoreSteam.com's Traction® to manage projects using the Six Sigma DMAIC and DFSS processes.
Remember to review old control charts for the process if they exist - there may be notes from earlier incidents that will illuminate
the current condition.
• Process average, or x̄
• Upper Specification Limit (USL) and Lower Specification Limit (LSL).
• The Process Standard Deviation ( σest). This can be calculated directly from the individual data, or can be estimated by: σest =
R̄ / d2
Cp is calculated as follows:
Cp is often referred to as "Process Potential" because it describes how capable the process could be if it were centered precisely
between the specifications. A process can have a Cp in excess of one but still fail to consistently meet customer expectations,
as shown by the illustration below:
The measurement that assesses process centering in addition to spread, or variability, is Cpk. Think of Cpk as a Cp calculation
that is handicapped by considering only the half of the distribution that is closest to the specification. Cpk is calculated as
follows:
The illustrations below provide graphic examples of Cp and Cpk calculations using hypothetical data:
Summary
While the initial resource cost of statistical process control can be substantial the return on investment gained from the
information and knowledge the tool creates proves to be a successful activity time and time again. This tool requires a great
deal of coordination and if done successfully can greatly improve a processes ability to be controlled and analyzed during
process improvement projects.
Exercise #1
I. Objectives:
1.1. To determine the process capability of a certain manufacturing operations.
1.2. To know the characteristics of certain object using Standard Deviation.
1.3. To know the importance of standard deviation in making decision in rejecting the product.
II. Discussions:
2.1. Standard deviation is a statistical term that measures the amount of variability or dispersion
around an average. Standard deviation is also a measure of volatility.
2.2. Statistical Process Control (SPC) is an industry-standard methodology for measuring and
controlling quality during the manufacturing process.
III. Materials:
3.1. Sets of chalks (25 pcs. Minimum)
3.2. Vernier Caliper
3.3. Calculator
3.4. Data Sheet
IV. Procedures:
4.1. Prepare all the materials to be needed.
4.2. Measure the length and diameter of each chalk using caliper.
4.3. Compute the Standard Deviation.
4.4. Also, compute the Upper Class Limit (UCL) and Lower Class Limit (LCL) to determine if it is
passing or reject product.
4.5. Record the data.
V. Completed Data Sheet:
VI. Computations:
Length:
∑𝒏𝒊=𝟎(𝒙 − 𝒙
̅)𝟐
𝑺𝑫 = √
𝒏
𝑺𝑫
(7.4 + 3.17 + 1.64 + 14.29 + 8.53 + 10.37 + 5.38 + 4.93 + 5.38 + 8.53 + 7.95 + 4.49 + 3.17 + 7.4 + 9.73
√ +9.12 + 8.53 + 6.86 + .0784 + 9.12 + 8.53 + 11.7 + 6.35 + 5.86 + 5.38
=
𝟐𝟓
𝑺𝑫 = 𝟕. 𝟐𝟒
UCL = 99
LCL = 55.56
∑𝒏𝒊=𝟎(𝒙 − 𝒙
̅)𝟐
𝑺𝑫 = √
𝒏
. 𝟎𝟒 + . 𝟎𝟗+. 𝟎𝟗+. 𝟏𝟔+. 𝟎𝟏 + 𝟎+. 𝟎𝟏+. 𝟎𝟏+. 𝟎𝟒 + 𝟎+. 𝟏𝟔+. 𝟎𝟒+. 𝟎𝟏 + 𝟎+. 𝟎𝟏+. 𝟎𝟗 +
√ . 𝟎𝟏+. 𝟎𝟒+. 𝟎𝟗+. 𝟎𝟒+. 𝟎𝟒+. 𝟎𝟗+. 𝟏𝟔+. 𝟎𝟗+. 𝟎𝟏
𝑺𝑫 =
𝟐𝟓
𝑺𝑫 = . 𝟔𝟗
UCL = 11.87
LCL = 7.73
VII. Observations:
- As the data that is observed, the chalk that are used is created by precision
with little error that is not that significant.
VIII. Conclusions:
- The conclusion is that the population used in this observation is
manufactured accordingly to the specifications that are needed by the
manufacturer as most of the data shows that all samples used are done in
near the average and acceptable margin.
IX. Reference: