02 Special Pressure Gauge
02 Special Pressure Gauge
PED 2014/68/UE
For measurement of low pressure and vacuum, for use on gas and dry air.
RC4 - 12/15
IN ORDER TO IMPROVE THEIR PRODUCTION, MESSRS. NUOVA FIMA RESERVE THE RIGHT TO THEMSELVES TO MAKE ALL THE MODIFICATIONS THAT THEY DEEM INDISPENSABLE AT ANY TIME. UPDATED DATA-SHEETS ARE AVAILABLE ON SITE: www.nuovafima.com
A - LOWER CONNECTION D - BACK CONNECTION
OPTIONS
B- “U”-clamp, for back connection pressure gauges
E- Front flange, for back connection pressure gauges
Copyright © Nuova Fima srl. All rights reserved. Any part of this publication should not be reproduced without a written Nuova Fima’s srl approval
MN9
capsule pressure gauges
DS 4”, 6” (100-150mm)
PED 2014/68/UE
For measurement of low pressure and vacuum within the range -600...0 to 0...600 mbar, for use on gas and dry air.
RC5 - 12/15
IN ORDER TO IMPROVE THEIR PRODUCTION, MESSRS. NUOVA FIMA RESERVE THE RIGHT TO THEMSELVES TO MAKE ALL THE MODIFICATIONS THAT THEY DEEM INDISPENSABLE AT ANY TIME. UPDATED DATA-SHEETS ARE AVAILABLE ON SITE: www.nuovafima.com
A - LOWER CONNECTION D - BACK CONNECTION
dimensions : mm
OPTIONS
MODEL MN9 MN9/18
C40 - AISI 316L st. st. case and ring ◆
K10 - Accuracy class 1 (only for ≥ 25 mbar range) ◆
MIX - Stainless steel movement ◆
B - “U”-clamp, for back connection pressure gauges ◆ ◆
C - Back flange, for lower connection pressure gauges ◆ ◆
E- Front flange, for back connection pressure gauges ◆ ◆
T32 - Window glass ◆ ◆
The sensing element is an elastic diaphragm, with concentric corrugations that drives the amplifying movement through a ball-joint. They are
designed to measure pressure or vacuum of viscous, sedimentous, crystallisable or corrosive fluids. Compared to the bourdon tube system they are
more robust and are better able to withstand overpressure or aggressive fluids.
2.42.1 - MN12/18
Design: EN 837-3.
0...1 bar -0,6...1 bar
Ranges: from 0...10 INWC to 0...360 psi, (from 0...25 mbar to 0...25
bar), vacuum and combined vacuum/pressure (or equivalent units). 0...1,6 bar -1...0,6 bar
Accuracy class: 1,6 as per EN 837-3 (1,0 as per EN 837-3 on request). 0...2,5 bar -1...1,5 bar
0...4 bar -1...3 bar
Ambient temperature: -22...+149°F (-40...+65 °C).
0...6 bar -1...5 bar
Process temperature: max. +212°F; +100 °C.
0...10 bar -1...9 bar
Working pressure: max 75% of the full scale value.
0...16 bar -1...15 bar
Overpressure limit: 25% of the full scale value.
0...25 bar -1...24 bar
Thermal drift: ±0,6% every ±10°C of ambient temperature.
0...25 mbar -10...15 mbar
Protection: IP 55 as per EN 60529/IEC 529.
0...40 mbar -15...10 mbar
Process connection: AISI 316L st.st.
0...60 mbar -15...25 mbar
Elastic element: AISI 316 Ti st.st. diaphragm. 0...100 mbar -25...15 mbar
Diaphragm gasket: PTFE. 0...160 mbar -20...40 mbar
Case: acciaio inox st.st. 0...250 mbar -40...20 mbar
Ring: acciaio inox st.st., bayonet lock. 0...400 mbar -40...60 mbar
Window: tempered glass (with external zero adjustement on request). 0...600 mbar -60...40 mbar
Movement: stainless steel. -60...100 mbar
Dial: aluminium, white with black markings. -100...60 mbar
Pointer: aluminium, micrometric adjustable. -100...150 mbar
Special version: -150...100 mbar
- high overpressure : 10 time the FSV but not over 30 psi (2 bar) for -25...0 mbar -150...250 mbar
pressure ranges from 0...10 INWC to 0...6 psi (25...400 mbar); 5 time -40...0 mbar -250...150 mbar
the FSV but not over 600 psi (40 bar), for pressure ranges 10...360 -60...0 mbar -200...400 mbar
psi (0,6...25 bar). -100...0 mbar -400...200 mbar
-160...0 mbar -400...600 mbar
2.45.1 - MN12/18/T -250...0 mbar -600...400 mbar
Process connection: AISI 316L, PTFE coated. -400...0 mbar
Elastic element: AISI 316 Ti st.st. diaphragm, PTFE coated. -600...0 mbar
Other features as MN12/18. -1...0 bar
RC6 - 08/16
IN ORDER TO IMPROVE THEIR PRODUCTION, MESSRS. NUOVA FIMA RESERVE THE RIGHT TO THEMSELVES TO MAKE ALL THE MODIFICATIONS THAT THEY DEEM INDISPENSABLE AT ANY TIME. UPDATED DATA-SHEETS ARE AVAILABLE ON SITE: www.nuovafima.com
0.87 (22) 0.91 (23)
Range DS F a b c d d1 h h1 D D1 ch L Weight
E 0.51 1.90 0.63 4.35 3.97 3.09 5.90 0.86 0.78 5.73 lbs
0...10 INWC to 0...6 psi 4”(100mm) (13) (48,5) (16,1) (110,6) (101) (78,5) (150) (22) (20) 2,6 kg
(25...400 mbar) G 41M 0.59 1.98 0.64 6.33 5.88 4.36 5.90 0.86 0.78 6.50 lbs
6”(150mm) G 1/2 B (15) (50,5) (16,5) (161) (149,6) (110,8) (150) (22) (20) 2,95 kg
E 0.51 1.90 0.63 4.35 3.97 3.12 3.85 0.86 0.78 3.85 lbs
43M
10...360 psi 4”(100mm) 1/2-14 NPT (13) (48,5) (16,1) (110,6) (101) (79,5) (98) 1,75 kg
(22) (20)
(0,6...25 bar) G 0.59 1.98 0.64 6.33 5.88 4.40 3.85 0.86 0.78 4.62 lbs
6”(150mm) (15) (50,5) (16,5) (161) (149,6) (111,8) (98) (22) (20) 2,1 kg
dimensions : inches (mm)
OPTIONS
Model MN12/18 MN12/18/T
Electric contacts for pressure ranges ≥ 25 INWC (≥ 60 mbar) (1) ◆ ◆
C40 - Case and ring AISI316L st.st. ◆ ◆
E65 - Protection degree IP 65 as per EN 60529/IEC 529 (4) ◆ ◆
L22 - Maximum pointer Wiebrock (4) ◆ ◆
M23 - Monel 400 protection diaphragm ◆ ◆
M22 - Hastelloy C protection diaphragm ◆ ◆
M29 - Tantalium protection diaphragm ◆ ◆
M26 - PTFE diaphragm protection ◆
P02 - Degreasing for oxygen use ◆ ◆
R10 - Glycerine filling +32...+149°F (0...+65 °C) (2) (3) (4) ◆ ◆
R11 - Silicon oil filling -40...+149°F (-40...+65 °C) (2) (3) (4) ◆ ◆
T01 - Tropicalization ◆
T32 - Safety glass window (4) ◆ ◆
(1) Codes, description and wiring on data sheet MN14. (3) Accuracy class 2,5 as per EN 837-3.
(2) For pressure ranges ≥ 10 psi (600 mbar) only. (4) Not available with electric contacts
The sensing element is an elastic diaphragm, with concentric corrugations that drives the amplifying movement through a ball- joint.
They aare designed to measure pressure or vacuum of viscous, sedymentous, crystallisable or corrosive fluids. Compared to the bourdon tube
system they are most robust and are better able to withstand overpressure or aggressive fluids.
OPTIONS
Model MN12/18 MN12/18/T
Electric contacts for pressure ranges ≥ 25 INWC (60 mbar) (1) (1) ◆ ◆
C40 - Case and ring AISI316L st.st. ◆ ◆
E65 - Protection degree IP 65 as per IEC 529 (4) ◆ ◆
L22 - Maximum pointer Wiebrock (4) ◆ ◆
M23 - Monel 400 protection diaphragm ◆ ◆
M22 - Hastelloy C protection diaphragm ◆ ◆
M29 - Tantalium protection diaphragm ◆ ◆
M26 - PTFE diaphragm protection ◆ ◆
P02 - Degreasing for oxygen use ◆ ◆
R10 - Glycerine filling +32...+149°F (0...+65 °C) (2) (3) (4) ◆ ◆
R11 - Silicon oil Silicon oil filling -40...+149°F (-40...+65 °C) (2) (3) (4) ◆ ◆
T01 - Tropicalization ◆ ◆
T32 - Safety glass window (4) ◆ ◆
(1) Codes, description and wiring on data sheet MN14. (3) Accuracy class 2,5 as per EN 837-3.
(2) For pressure ranges ≥ 10 psi (600 mbar) only. (4) Not available with electric contacts
RC5 - 03/14
IN ORDER TO IMPROVE THEIR PRODUCTION, MESSRS. NUOVA FIMA RESERVE THE RIGHT TO THEMSELVES TO MAKE ALL THE MODIFICATIONS THAT THEY DEEM INDISPENSABLE AT ANY TIME. UPDATED DATA-SHEETS ARE AVAILABLE ON SITE: www.nuovafima.com
ø 150 ø 98
ANSI STANDARDS
dimensions : inches
DN (1) Classe Code H H1 E M I g L f N (2)
1/2" 150 4AA 1.33 1.06 3.54 1.37 0.59 0.08 2.37 1/2" 13UNC 4
1/2" 300 4BA 1.06 1.06 3.74 1.37 0.59 0.08 2.62 1/2" 13UNC 4
1/2" 600 4DA 1.90 1.06 3.74 1.37 0.59 0.27 2.62 1/2" 13UNC 4
3/4" 150 5AA 1.06 1.06 4.33 1.68 0.78 0.08 2.75 1/2" 13UNC 4
3/4" 300 5BA 1.49 1.06 4.53 1.68 0.78 0.08 3.25 5/8" 11UNC 4
3/4" 600 5DA 1.90 1.06 4.53 1.68 0.78 0.27 3.25 5/8" 11UNC 4
1" 150 6AA 1.06 1.06 4.33 2 0.98 0.08 3.12 1/2" 13UNC 4
1" 300 6BA 1.49 1.10 4.92 2 0.98 0.08 3.50 5/8" 11UNC 4
1" 600 6DA 1.90 1.10 4.92 2 0.98 0.27 3.50 5/8" 11UNC 4
(1) 1” 1/2, 2” also available (2) N° threaded holes.
Copyright © Nuova Fima srl. All rights reserved. Any part of this publication should not be reproduced without a written Nuova Fima’s srl approval
MN12/18 ABS
diaphragm pressure gauge
for absolute pressures
DS 4”, 6” (100-150mm)
The measurement element composed by a concentric waving diaphragm, separates an upper housing called "of reference" which is empty, from a
lower housing where the fluid pressure gets in. The upper housing is isolated by a bellows from the atmospheric pressure and it allows to transmit
the bending diaphragm movement, under the fluid pressure action, to the pointer through a joint and a linkage. In order to be a suitable support for
the diaphragm and to ensure a high instrument resistance to overpressure, the upper part of the reference housing is as rippled as the diaphragm.
The instrument case is exposed to the atmospheric pressure therefore it is possible to install optional accessories inside or outside it.
RC6 - 05/14
IN ORDER TO IMPROVE THEIR PRODUCTION, MESSRS. NUOVA FIMA RESERVE THE RIGHT TO THEMSELVES TO MAKE ALL THE MODIFICATIONS THAT THEY DEEM INDISPENSABLE AT ANY TIME. UPDATED DATA-SHEETS ARE AVAILABLE ON SITE: www.nuovafima.com
0.87 (22) 0.91 (23)
RANGE DS F a b c d d1 h h1 D D1 ch L Weight
E 0.51 1.91 0.63 4.35 3.98 - 3.09 - 5.91 0.87 0.79 5.73 lbs
60...400 4” (100mm) (13) (48,5) (16,1) (110,6) (101) - (78,5) - (150) (22) (20) 2,6 kg
mbar Abs
G 41M 0.59 1.99 0.65 6.34 5.89 - 4.36 - 5.91 0.87 0.79 6.50 lbs
6” (150mm) G 1/2 B (15) (50,5) (16,5) (161) (149,6) - (110,8) - (150) (22) (20) 2,95 kg
E 0.51 1.91 0.63 4.35 3.98 3.13 - 3.86 - 0.87 0.79 3.85 lbs
43M
0,6 ...1,6 4” (100mm) 1/2-14 NPT (13) (48,5) (16,1) (110,6) (101) (79,5) - (98) - (22) (20) 1,75 kg
bar Abs G 0.59 1.99 0.65 6.34 5.89 4.40 - 3.86 - 0.87 0.79 4.62 lbs
6” (150mm) (15) (50,5) (16,5) (161) (149,6) (111,8) - (98) - (22) (20) 2,1 kg
OPTIONS
Electric contacts (1)
E65 - Protection IP 65
T01 - Tropicalization
T32 - Safety glass
Copyright © Nuova Fima srl. All rights reserved. Any part of this publication should not be reproduced without a written Nuova Fima’s srl approval
MD13
differential pressure gauges PN 100
with single diaphragm
DS 6” (150mm)
These instruments are used to check differential pressures of liquids wich do not have high viscosity and do not crystalizee.
Accuracy class: 2,5 as per EN 837. RANGE mbar mmH2O bar kPa
Scale amplitude: 180°.
Statica Pressure: max 1500 psi (100 bar). 0...0,6 ◆
Ambient temperature: -13...+149°F (-25...+65 °C.) 0... 1 ◆
Process fluid temperature: +302°F (+150 °C). 0...1,6 ◆
Thermal drift: ± 0,8 % every ±50°F (± 10° C) of ambient temperature 0...2,5 ◆
Protection degree: IP 55 as per EN 60529/IEC 529. 0...4 ◆
Socket material: AISI 316L st.st. 0...6 ◆
Elastic element: Duratherm diaphragm. 0...10 ◆
Gasket: VITON and PTFE. 0...16 ◆
Case: AISI 304 st.st. 0...25 ◆
Ring: AISI 304 st.st., bayonet lock
Window: tempered glass.
0...40 ◆
Movement: stainless steel.
0...60 ◆
Dial: aluminium, w h i t e w i t h b l a c k m a r k i n g s
0...100 ◆
Pointer: adjustable, aluminium, black.
0...160 ◆
Weight: 12.12 lbs (5,5 kg). 0...250 ◆
0...400 ◆ ◆
0...600 ◆ ◆
0...1000 ◆ ◆
0...1600 ◆
0...2500 ◆
0...4000 ◆
0...6000 ◆
0...10000 ◆
RC4- 06/14
1.99 7.48
1.99 (50,5) (190)
(50,5) 5.91
(150) 3.35
3.35 0.98 (25) (85)
(85) 4.80 ø 6.61...7.01
0.59 (15) ø (168...178)
(122)
0.12
IN ORDER TO IMPROVE THEIR PRODUCTION, MESSRS. NUOVA FIMA RESERVE THE RIGHT TO THEMSELVES TO MAKE ALL THE MODIFICATIONS THAT THEY DEEM INDISPENSABLE AT ANY TIME. UPDATED DATA-SHEETS ARE AVAILABLE ON SITE: www.nuovafima.com
120
(3)
0.35 (9)
°
ø 6.34 ø 5.91 3.54 ø 6.34 ø 5.91
(161) (150) (90) 1.97 (50) (161) (150)
Lower (Mounting code A) , with back Lower (Mounting code A) , with front flange
flange (Option code C) (Option code E)
OPTIONS
C- Back flange R10 - Glycerine filled case. Ambient temp. +32...+149 °F (0...+65 °C). (2)
E- Front flange (1) (2) R11 - Silicon oil filled case. Ambient temp. -40...+149°F (-40...+65 °C).
C40 - Case and ring AISI 316L st.st. S31 - 2" pipe mounting bracket
E65 - Protection degree IP65 (2) T01 - Tropicalization (2)
L22 - Maximum pointer IP65 on Plexiglas window (2) T32 - Safety glass window (3)
2G9 - Execution: ATEX : II 2G c (2)
2D9 - Execution: ATEX : II 2GD c
(1) For constructive details see Atex execution catalogue sheet (3) Codes, description and wiring on data-sheet MN14
(3) Not available with eletric contacts
Section / Model / Case / Mounting / Diameter / Special version /Range / Process connection / Options
2 13 1 A G --- 41M - G 1/2 A M C, E
43M - 1/2” NPT M E65...T32
23F - 1/4” NPT F
Copyright © Nuova Fima srl. All rights reserved. Any part of this publication should not be reproduced without a written Nuova Fima’s srl approval
MD14
bourdon tube pressure gauges
anti-vibration heavy duty version
DS 4” (100mm)
PED 2014/68/EU
Designed to indicate differential pressure of gas or not cristalising fluid within the range 0...10 mbar to 0...160 mbar.
RC4 - 06/14
7.48
5.91 (190)
(150)
0.12 (3) 1.02 7.01 (178)
4.80(122) (26)
6.61 (168)
0.51
(13)
3.54 1.89
(90) (48)
IN ORDER TO IMPROVE THEIR PRODUCTION, MESSRS. NUOVA FIMA RESERVE THE RIGHT TO THEMSELVES TO MAKE ALL THE MODIFICATIONS THAT THEY DEEM INDISPENSABLE AT ANY TIME. UPDATED DATA-SHEETS ARE AVAILABLE ON SITE: www.nuovafima.com
0.51
(13)
0.24
(6)
1.97
(50) 1.97
(50)
Lower (Mounting code A) , with back flange Lower (Mounting code A) , with front flange (Option code
(Option code C): DS 4”, 6” (100-150mm) F): DS 4” (100mm)
4” (100mm) 41M (13) (48,5) (4) (110,5) (101) 3.35 3.46 2.20 3.11 3.15 3,33 kg
≥ 60 mbar
G 1/2 A (85) (88) (56) (79) (80) (3,33)
43M 3.94 3.96 2.56 3.94 4.33 5,29 kg
G ≤ 40 mbar 1/2-14 NPT 0.59 1.99 0.10 6.34 5.91 (100) (100,5) (65) (100) (110) (5,29)
6” (150mm) (15) (50,5) (2,5) (161) (150) 3.35 3.46 2.20 3.11 3.15 3,83 kg
≥ 60 mbar
(85) (88) (56) (79) (80) (3,83)
dimensions : inches (mm)
OPTIONS
C - Back flange Electric contacts (1)
E - Front flange R11 - Silicon oil filled case. Ambient temp. -40...+149°F (-40...+65 °C). (1) (3) (4)
C40 - AISI 316L st.st. case and ring S31 - 2" pipe mounting bracket
L22 - Maximum pointer IP65 (2) (4) T01 - Tropicalization
Q01 - Special dial T32 - Safety glass window (4)
R10 - Case glycerine filling. Ambient temp. +32...+149°F (0...+65 °C). (4)
(1) Codes, descriptions and wiring on data-sheet MN14: for pressure ranges ≥ 20 mbar
(2) To be ordered with Plexiglas window
(3) Window gasket and blow out vent: VITON
(4) Not available with electric contacts
Section / Model / Case / Mounting / Diameter / Special version /Range / Process connection / Options
2 14 1 A E --- 41M - G 1/2 A M C, E
G 43M - 1/2” NPT M C40...T32
23F - 1/4” NPT F
Copyright © Nuova Fima srl. All rights reserved. Any part of this publication should not be reproduced without a written Nuova Fima’s srl approval
MD15
differential pressure gauges PN 200
with double diaphragm
DS 4”, 6” (100-150mm)
These instruments are used to check differential pressures of gaseous liquids wich do not have high viscosity and do not crystalizee. In presence of
high temperature, high viscosity and corrosive process fluid or which can crystalize these instruments can be fitted with remote
mounting diaphragm seals.
RANGE Static pressure, one side : Static pressure, both side : Scale amplitude Scale amplitude
psi (bar) psi (bar) DS 4” (100mm) DS 6” (150mm)
RC6 - 06/14
(15)
4.80 (122) 0.08 0.51
(2) (20) ø 4.72
(120)
0.12
(3)
0.35
(9) 120°
1.97 ø 4.35
(110,6) ø 3.98
3.54 (50) (101)
(90)
4.43
0.35 (112,5) M5
IN ORDER TO IMPROVE THEIR PRODUCTION, MESSRS. NUOVA FIMA RESERVE THE RIGHT TO THEMSELVES TO MAKE ALL THE MODIFICATIONS THAT THEY DEEM INDISPENSABLE AT ANY TIME. UPDATED DATA-SHEETS ARE AVAILABLE ON SITE: www.nuovafima.com
(9) 4.43 (112,5)
0.28 (7)
Lower (Mounting code A) , with back flange Lower (Mounting code A) , with front flange (Option code
(Option code C): DS 4”, 6” (100-150mm) F): DS 4” (100mm)
1.99
(50,5) ø 7.48 (190)
ø 6.61...7.01
0.98 (168...178)
(25)
☐ ☐ Weight :
DS a b d d1 lbs (kg) 120°
≤ 0,16 bar > 0,16 bar
OPTIONS
C- Back flange for DN100-150 instruments D10 - Elastic element and connection MONEL 400 (2)
F- Front flange for DN100 instruments E65 - Protection degree IP65 (8)
E- Front flange for DN150 instruments M23 - Protection diaphragm Monel 400 (2)
Sliding contacts for DN 150 (amplitude180°) (1) R11 - Case filling with silicon oil. Ambient temp. -40...+149°F (-40...+65 °C) (5) (8)
E30 - NACE version MR0103/MR0175 (ISO15156) (3) T01 - Tropicalization
L22 - Maximum pointer IP 65 on plexiglas window (8) T32 - Safety glass window (8)
R10 - Case glycerine filling. Ambient temp. +32...+149°F (0...+65 °C) (8) C40 - Case and ring AISI 316L st.st.
S31 - 2"pipe mounting bracket 2G9 - ATEX versions : II 2G c (7) (8)
NR. 2 diaphragm seals mounting (6) 2D9 - ATEX versions : II 2GD c (7) (8)
(1) Code and description see data sheet MN14 (6) Contact technical department
(2) Accuracy 2,5 as per EN837,for ranges < 160 IN H2O (400 mbar) (7) For constructive details see Atex execution data-sheet
(3) To be ordered with Monel 400 or Hastelloy C diaphragms (8) Not available with electric contacts
(5) Window gasket and blow out vent Viton
Section / Model / Case / Mounting / Diameter / Special version /Range / Process connection / Options
2 15 1 A E --- 41M - G 1/2 A M C...E
G D10 43M - 1/2” NPT M E30...2D9
43F - G 1/2 F
MD16
differential pressure gauges PN 100
with double diaphragm
DS 4”, 6” (100-150mm)
These instruments are used to check filter obstructions, pressure drops, flow rate differences, level, measurements and generally the difference
between two pressures of equal or different circuits. The measuring element is formed by two diaphragms, acting on the same movement. In this
way the pointer senses only the difference between the two pressures corresponding respectively to upstream and downstream circuit pressure.
RC6 - 06/14
b (50,5) (Ø 190)
0.59
a ☐ 3.34 (15) 5.90 (150) 0.98 Ø 6.61... 7
(85) (25) ☐ 3.34 (Ø168...178)
4.80 (122) (85)
0.12 (3)
0.35
(9)
d 1.97 Ø 5.88
1 3.34 (Ø149,6)
(85) (50)
IN ORDER TO IMPROVE THEIR PRODUCTION, MESSRS. NUOVA FIMA RESERVE THE RIGHT TO THEMSELVES TO MAKE ALL THE MODIFICATIONS THAT THEY DEEM INDISPENSABLE AT ANY TIME. UPDATED DATA-SHEETS ARE AVAILABLE ON SITE: www.nuovafima.com
3.34
4.42 (85)
0.35 (112,5)
(9)
L 0.28 (7) 0.24 (6)
1.97
(50)
G 1/2 B 3.97
1.97 (101)
(50) Ø 6.33
(Ø 161)
p
Lower (Mounting code A) , with back flange Lower (Mounting code A) , with front flange (Option code
(Option code C): DS 4”, 6” (100-150mm) F : DS 4” - 100mm; Option code E : DS 6” - 150mm)
OPTIONS
C - Back flange P02 - Oxygen service (5)
F- Front flange for DN100 instruments R10 - Glycerine filled case. Ambient temp. +32...+149°F (0...+65 °C). (8)
E - Front flange for DN150 instruments R11 - Silicon oil filled case. Ambient temp. -40...+149°F (-40...+65 °C). (6) (8)
C40 - AISI 316L st.st. case and ring S31 - 2" pipe mounting bracket
E30 - NACE MR0175 version (ISO 15156) (2) T01 - Tropicalization
E65 - Protection IP65 (3) (8) T32 - Safety glass window (8)
L22 - Maximum pointer IP65 (4) 2G9 - ATEX versions : II 2G c (8) (9)
M23 - MONEL 400 diaphragms 2D9 - ATEX versions : II 2GD c (8) (9)
Mechanical electric contacts (1)
(1) Codes, descriptions and wiring on data-sheet MN14 (6) Window gasket and blow out vent: VITON
(2) Available for ranges ≥ 1 bar. To be ordered with Monel 400 diaphragm. (8) Not available with electric contacts
(3) To be ordered with Plexiglas window (9) For constructive details see Atex execution data-sheet
(4) Available only for ranges ≥ 1 bar
(5) Filling of internal chamber with Fluorolube
Section / Model / Case / Mounting / Diameter / Special version /Range / Process connection / Options
2 16 1 A E --- 41M - G 1/2 A M C, E
G 43M - 1/2” NPT M C40...2D9
23F - 1/4” NPT F
Copyright © Nuova Fima srl. All rights reserved. Any part of this publication should not be reproduced without a written Nuova Fima’s srl approval
MD17
differential pressure gauges PN 400
with double diaphragm
DS 4”, 6” (100-150mm)
These instruments are used to check filter obstructions, pressure drops, flow rate differences, level, measurements and generallythe difference between
two pressures of equal of different circuits. The measuring element is formed by two diaphragms, acting on the same movement. In theis way the pointer
senses only the difference between the two pressures corresponding respectively to upstream and downstream circuit pressure.
RB5- 06/14
3.35 (85) 0.59 (64)
(15) (132)
5.91 (150)
0.08 0.51 ø 4.72
4.80 (122) (2) (20) (120)
0.12
(3)
0.35
(9)
IN ORDER TO IMPROVE THEIR PRODUCTION, MESSRS. NUOVA FIMA RESERVE THE RIGHT TO THEMSELVES TO MAKE ALL THE MODIFICATIONS THAT THEY DEEM INDISPENSABLE AT ANY TIME. UPDATED DATA-SHEETS ARE AVAILABLE ON SITE: www.nuovafima.com
0.35 4.27
(9) (108,5)
M5
4.27 (108,5)
Lower (Mounting code A) , with back flange Lower (Mounting code A) , with front flange (Option code
(Option code C): DS 4”, 6” (100-150mm) F): DS 4” (100mm)
DS a b c d d1 Weight :
lbs (kg) 120°
OPTIONS
C- Back flange for DN100-150 instruments L22 - Maximum pointer IP 65 on plexiglas window (3) (6)
F- Front flange for DN100 instruments M23 -Protection diaphragm MONEL 400 (4)
E- Front flange for DN150 instruments R10 - Case glycerine filling. Ambient temp. +32...+149°F (0...+65 °C). (6)
Electric contacts (amplitude 180°) (1) R11 - Case filling with silicon oil. Ambient temp. -40...+149°F (-40...+65 °C). (6)
C40 - Case and ring AISI 316L st.st. S31 - 2”pipe mounting bracket
E30 - NACE version MR0103/MR0175 (ISO 15156) (2) T32 - Safety glass window (6)
E65 - Protection degree IP 65 (6) 2D9 - Execution: ATEX : II 2GD c
2G9 - Execution: ATEX : II 2G c (5) (6)
(1) Codes, descriptions and wiring on data-sheet MN14 (5) For constructive details see ATEX execution data-sheet
(2) To be ordered with Monel 400 or Hastelloy C diaphragms (6) Not available with electric contacts
(3) To be ordered with plexiglas window
(4) Ac curacy 2,5 secondo EN 837
Section / Model / Case / Mounting / Diameter / Special version /Range / Process connection / Options
2 17 1 A E --- 41M - G 1/2 A M C...E
G 43M - 1/2” NPT M C40...2D9
43F - 1/2” NPT F
MD18
differential pressure gauges
with double Bourdon tube,
DS 4” (100mm)
PED 2014/68/UE
These instruments are used to check filter obstructions, pressure drops, flow rate differences, level, measurements and generally a difference between
two pressures of onel or different circuits. The measuring element is formed by two bourdon tubes, acting on the same movement. In this way the
pointer shows only the difference between the two pressures corresponding respectively to upstream and downstream pressure of the circuit.
RC4- 06/14
b b
1 D
a
a
E
120
°
d1
d1
IN ORDER TO IMPROVE THEIR PRODUCTION, MESSRS. NUOVA FIMA RESERVE THE RIGHT TO THEMSELVES TO MAKE ALL THE MODIFICATIONS THAT THEY DEEM INDISPENSABLE AT ANY TIME. UPDATED DATA-SHEETS ARE AVAILABLE ON SITE: www.nuovafima.com
j
j
1
F
F
f
y
y
b D
a
E
OPTIONS
C- Back flange for DN100-150 instruments
120
°
j R11 - Case filling with silicon oil. Ambient temp. -40...+149°F (-40...+65 °C)
T01 - Tropicalization
T31 - Plastic window
F
f
T32 - Safety glass window
y
a1
Copyright © Nuova Fima srl. All rights reserved. Any part of this publication should not be reproduced without a written Nuova Fima’s srl approval
-2-
MN14
electric contacts for diaphragm pressure gauges
PED 2014/68/EU
Are accessories with movable contacts in air, which open or close electric circuits depending of the position of the indicating pointer. They are used
with Bourdon tube pressure gauges, bellows, diaphragm of NUOVA FIMA production, in such way they become pressure switches: the optimal and
sure solution to automatize any kind of equipment.
Contacts: sliding, magnetic snap action. Functional and constructive Protection: IP 44 as per IEC 529, (option IP 55).
characteristics, wiring and electrci schemas are shown on the attached Contact material: Silver-Nickel 80%-20% (options Gold-Silver and
data-sheet: “ELECTRIC CONTACT”. Platinum-Iridium).
Accuracy: when the indicating pointer is affected by the contact link Window: Makrolon.
add to the gauge accuracy the 50% of their accuracy (with the exclusion Overpressure: non suitable.
of the working area within the 5% if the contact is magnetic type).
Contact setting: over an arc of 270 °, trough the knob placed on front lens
or trough removable key.
Electrical wiring: junction box PG9 as per DIN 43650 or cable 0,5 mt.
Ambient temperature: -25...+65 ∞ C .
DIMENSIONS (mm)
A B
Single contact
DS A B C
100 29 95 110,6
150 29 141 161
Double contacts
DS A B C
100 36 95 110,6
150 36 141 161
RB1.2 - 06/14
MODEL MN12/18 DS 4”- 6” (100-150 mm)
IN ORDER TO IMPROVE THEIR PRODUCTION, MESSRS. NUOVA FIMA RESERVE THE RIGHT TO THEMSELVES TO MAKE ALL THE MODIFICATIONS THAT THEY DEEM INDISPENSABLE AT ANY TIME. UPDATED DATA-SHEETS ARE AVAILABLE ON SITE: www.nuovafima.com
0,27 (7)
Back cable exit 2 poles + GND (1) 3 poles + GND (1) 4 poles + 1
ø cable: inches (mm) 0,19 (4,8) 0,23 (6) 0,27 (7)
(1) for front flange mounting (cod. E)
Contact type Sliding and magnetic snap-action contact Sliding and magnetic snap-action contact
Back cable exit 2 poles + GND (1) 3 poles + GND (1) 4 poles + 1 (1) 2 poles + GND (2) 3 poles + GND (2) 4 poles + 1 (2)
ø cable: inches (mm) 0,19 (4,8) 0,23 (6) 0,27 (7) 0,19 (4,8) 0,23 (6) 0,27 (7)
(1) for front flange mounting (cod. F)
(2) for front flange mounting (cod. E)
Contact type Sliding and magnetic snap-action contact Sliding and magnetic snap-action contact
Back cable exit 2 poles + GND (1) 3 poles + GND (1) 4 poles + 1 (1) 2 poles + GND (2) 3 poles + GND (2) 4 poles + 1 (2)
ø cable: inches (mm) 0,19 (4,8) 0,23 (6) 0,27 (7) 0,19 (4,8) 0,23 (6) 0,27 (7)
(1) for front flange mounting (cod. F)
(2) for front flange mounting (cod. E)
Copyright © Nuova Fima srl. All rights reserved. Any part of this publication should not be reproduced without a written Nuova Fima’s srl approval
MD13
single diaphragm differential pressure gauges
ATEX version
DS 6” (150mm)
These instruments are used to check differential pressures of liquids wich do not have high viscosity and do not crystalizee. They resist to static
pressure up to 100 bar. In presence of high temperature, high viscosity and corrosive process fluid these instruments can be fitted with remote
mounting diaphragm seals. They are in conformity with the essential Health and Safety Requirements laid down in European Directive 2014/34/UE
for Group II, Category 2G or 2GD equipment in the T1...T6 temperature classes. They are NOT suitable for ZONES 0 and 20.
They keep the same functional and constructive features as MD13 They keep the same functional and constructive features as MD13
model. This differ from it as follows : model. This differ from it as follows :
Ambient temperature: -22...+140 °F (-30...+60 °C). Damping liquids: glycerine 98%, silicon oil.
Max process fluid temperature: see table (measured on the lowest Ambient temperature:
point of socket). +59...+140 °F (+15...+60 °C) for glycerine filling;
Windows: high resistance safety glass. -22...+140 °F (-30...+60 °C) for silicon oil filling.
Dial marking: CE Ex II 2G c T6X TF9, model name and serial/lot Max process fluid temperature: see table (measured on the lowest
number. point of socket).
Special dial: ranges different from standard, custom artworks and Windows: high resistance safety glass.
dials without Nuova Fima logo are not available. Dial marking: CE Ex II 2GD c T6X TF9 IP65 T85°C, model name
Options: electric contacts, plexiglas or tempered glass windows and serial/lot number.
and maximum pointers are not available. Special dial: ranges different from standard, custom artworks and
Included documentation: Installation manual. dials without Nuova Fima logo are not available.
Options: electric contacts, plexiglas or tempered glass windows
and maximum pointers are not available.
Included documentation: Installation manual.
RC3 - 04/16
double diaphragm differential
pressure gauges,
ATEX version
DS 4”, 6” (100-150mm)
IN ORDER TO IMPROVE THEIR PRODUCTION, MESSRS. NUOVA FIMA RESERVE THE RIGHT TO THEMSELVES TO MAKE ALL THE MODIFICATIONS THAT THEY DEEM INDISPENSABLE AT ANY TIME. UPDATED DATA-SHEETS ARE AVAILABLE ON SITE: www.nuovafima.com
These instruments are used to check differential pressures of gases, or liquids wich do not have high viscosity and do not crystalizee. They resist
to static pressure up to 100, 200, 400 bar depending on model type MD15, MD16 and MD17. In presence of high temperature, high viscosity and
corrosive process fluid these instruments can be fitted with remote mounting diaphragm seals. They are in conformity with the essential Health
and Safety Requirements laid down in European Directive 2014/34/UE for Group II, Category 2G or 2GD equipment in the T1...T6 temperature
classes. They are NOT suitable for ZONES 0 and 20.