0 ratings0% found this document useful (0 votes) 82 views8 pagesTC NT
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here.
Available Formats
Download as PDF or read online on Scribd
FOTEK
Self-adaptive Fuzzy + PID
Temperature Controller
NT series
Complete Human- interface & Function
* BET »%* Output volume display
* BREET »* Load current display
* BARE RIIBE % Turn off control function
* RRSHRAR + Fast auto-tuning setting
MSE IIRE * Soff start function
DRS RE »* Ramp control function
* FHWA %* Manual output control function .
% SAUENOIDGMEATSHAE Communication function available cA CE Rohs
HBAS RRL RD A
FOTEK CONTROLS CO., LTD.FOTEK
Fuzzy + PID Intelligent Temperature Controller
I Model guiding / 38585]
z
5
ry
4 ey
3 1 [Series cami) INT: New generation Temperature controller
2 Outine one) 10:24°48100 20: 48°96°60 21: 96°48°60 22 22.6°75°100
(unt mm). 32: 34°75%65 48: 48°48°72(1/16 DIN) 72: 72°72"60__96. 96°96°60(1/16 DIN)
3 [Output method (izaat) _|R Relay (BA/250VAC) | NT-10RIO.25A/250VAC)_V: SSR (90mA/12V)_L: Linear output (@-20mA)
4 [optonea iiinarn) [CT Wah Hester break detecting * NTOR(O25AR50VAG) mA: DC ourent input VDC Votage input
5, [Optoned those) IRS: With RS-485 communication (MODBUS protocol) _S: PV transmitter
i How to set the function or parameter / MH]REWERSR
STW Swi
1, "Temperature setting status ; : Press SET key instantaneously to enter into the temperature setting status,
2. Auto-tuning status ; : Press ' & , Key 3 sec to set " Auto-tuning ,,then press " & , key 3 sec to reset it
3, "Manu-output status : Press "¥ , key 3 secto tur off the output control, then press the “SET , key to set the
Manu-output volume ; If press ‘ ¥ , key 3 sec may to release ‘ Manu-output status _
4. ‘Display mode selecting ,: Press "SET , key 3 sec to select display mode
‘41.Wthout CT type: Display " Output volume , (ux) then press "SET, key 3 sec» to dsplay “Temperature set value
4-2, With CT type: Display output volume ; (uax)—then press “SET, key 3 sec + to dsplay “Load curent Go.xx)
then press "SET, key 3 sec to display “Temperature sat value
5. Parameter setting status , :Press 'F , key 3 sec to enter into the parameter setting status,
6. Alarm selting status ; :Press ‘ SET, &' F , key 3 sec to enter into the Alarm setting status.
7. Communication stetting status :Press “SET, & TV _ key 3 sec to enter into the Communication stetting status.
8, ‘Soft start function , : Atthe final parameter of ‘setting of alarm, , Press “SET , key 3 sec to set the Soft start
setting value “ SV2 ,
the fixed output volume is set by the manual output volume,
9, “Ramping control, : Atthe “rAP, parameter in the “setting of alarm level, if “PAP=0, ,ithas not the ramping
control function,
if “PAPZO , twill perform the ramping control function,
410, “Display mode setting , :Atthe "Sdc, parameter in the ' Setting of parameter, level, if "Sdc=n, , twill be
kept on the selected display mode, If Sde= A. ,itwill be retumed to the Temperature
‘st value mode after 10 seconds,
1. GRRE, 242 SET, MPRA BIRR,
2. CEOROTHAE, : Hek, BESIOTTMEA "SURNAITARE, : EAE "AL, SHORDARRE TE MDRTHRAE
3, FRSA, = HV) RORORRBABA (Box “OFF, ) » AR "SET, SR AIADE Fava, (i
Fink) | SOMME AORTA VMAS FRR, RS
SEDOTRARHE < «
4. MRE) HB TSET, $25H
SA MCT: HIME, (ux) FR SET, 9H RRO
42. CTRL: “RHR (uo) RE SET, MSH NLT AMERT, Cou)
Hg SET, BH ARTE,
PORE CCR
5. BRR, RTF, MOR: HA SRIBIE , HME
6, RGR TR TSET, 8 °F, MOHD: LA TSReeaE, ARM
7. BBM, RSET, ROW, MIE ARRAS, HR
8. CRGRERIE, : ERRENRM— MBBS SET, Sewelee MMLKSLEIA (Sv2) . > AEM
Pana ME ©
9. One, © SESE RASH TAP, © TAP = 0, TESIRALRRIDNICHNE + APO, FEEAATIE
FBITRI «
10. "RRASDRE, : TES MEREMMANEM SSde, + (Sde=n, BUISANBET "ARREST |
FSdo= A, OBER ARG RRR IAU TES, ©
&FOTEK
Fuzzy + PID Intelligent Temperature Controller
I General Specification / #4848
F
Er So R yy
Model sae [ota | ntae | nt20 [ nTat [NTE [ Nrase | NT22 g
‘Outing (Umm) __ 94s | araars00 | aaraer2 | aarasrao | osrasrad [7272-60 | rosrso [22675100 | Sr75°65 F
‘Alem ouput Beam | Sege ao Two alarm Single lam [Two alarm
Power supa Lie {0-265 VAC/ S060 Hz or 26VDGIAC (Ontioned)
Power consumption aE VA max. oF 100mA max (24VDCIAC) P
Input method BARK PT/K/J/R/S/T/B/E/N/L(Selectable) or 4~mA or 0~10VDC ( Optioned) rs
Contol mothod BWR Fuzzy + PID or ON/OFF selectable +
Control output eas Relay or SSR or 4=20mA ( Optioned) A
Alar outout wets Relay ta (SA250VAC SPOT) S
Dislay range meee 999 ~ 9999 Pe)
Accuracy of splay BEE = (0.1% OF FS. + 1 IGT ES
Seting range 299 ~ 9998 Gi
Memory method EEPROM
Inslaton resistance AEN ‘OVER Sonn /s00vDe
Dilecticsvength ASAE OVER 2.5 KV/1 MINUTE.
Operating Grou ena 250 = BOC 1 35%4-85% RH
EMC standard
ESD : 8 KVAir Discharge (Level3) 7 EN-61000-42
RF Interference : 10V /M/ ENV-50140
Burst test: 2KV / EN61000-4-4
I Setting of Communication / SAS RBE
Contr sa
Ban
ie aes nee
"88
ua
ProssBET ¥ hoy] see
Coniafer NO.
iz 7
=255 ‘4 Range:1~255
ProssBET toy
Prose BET] kay
(“sxaeae—} 7]
¥
4 Trs+0,, :Modbus-RTU
2> Frs=1 ; :Modbus-ASCII
Fa
ca
=
1> "BPS =96.. 9500 bps >
‘Communication speed 96 /192/384 2 "bPS=192, :19200 bps 2
( giaeae ) 182] 3> TPS =384,, :38400 bps oS
roe ET] key Fa
Data configuration Bt eNt/601/8E1 > "bIt=BN1, :8bitnon parity co
THEA aNT 8N1/701/7E1 2 "bIt=801_ :8 bit odd party es
3> 'bIt=8Et ; :8 bit even pani z
ress] key parity z
44> "bIt=BN2_, :8 bitnon parity
5> "bIt=701. :7 bitodd panty
6> | bIt=7Et, :7 bit even parity
°
iProm
TMD ia
CRUE CCR
roy
a
FOTEK
Ii Setting of parameter / 2 iE
Fuzzy + PID Intelligent Temperature Controlle
Control satus
Te
Pross[E]hey Paseo
yc time
tam
Pross[SET] key
‘Au tring
Da
Pra
At tuning bias
eae
PressLSci key
Proportion band
1a
oy
Integral tie
ae
Pres
Dervalve ime
aes
ProseSET] Koy
Hysleresis
wise
Pr
Gain
Sea
Pross[SET] key
Input sleatng
Saat
oy
Unit selecting
mee
ProssISET key
Decimal point selecting
Ae
PressSET] key
Pres
input sesoing—] [Sh]
ABE L_4)
Fron ey
Control method seting
SHAR
Can
TL)
aa
-200 ~ 9999
0~ 3999
0~ 3999
0~ 3999
01-99
PTIKIJIRIS|
TIBIEINIL
tore
ort
-999 ~ 9999
Hr fob
o- 26
nia
1» FT = 0, : ONIOFF control
2> Disappeared in Linear output type
+ Tat
aT At
0, : Control status
41 : Auto tuning status
‘> Auto tuning value = * SV-tu
1> ET =0, » TP, 's disappeared
+> FET =0,— "1, is disappeared
1» eT =O,» Td, isdisappeared
1» FET = 0,» SHys, is appeared only
2> | PV>SV) + OutON
(PV< (SV-Hys) } -» Out OFF
+> Gain of output contro!
1 10 input type are selectable
1 fdp=0, : Without decimal point
2> 'dp=1, ! One decimal point
+> PV, = (PV+Sht)
+> Hr,
2 tebe,
Heating control
Cooling control
41> Refer to the mode of Alarm
BIA
Manual setting
Auto settingFOTEK
Fuzzy + PID Intelligent Temperature Controller
Ii Setting of alarm / $3383
F
| i
@
‘3
Converse] (Ba 0~ 9999 5
20 Tessa °
Press BETIs Eley Yoeee
Lockseting] [Lex 0-3 41> TLeke0 Unlock Leet :SV stable only
EE T_2 Loe2 :SVAAL setable;'Lok=3, : Alok
Fs 2
TALI Linsating | [ALS] -999~ 9999 1» Refer tothe mode of Alarm F
ALI SE Ta =
renpe] a
‘AL2 Limit seting —] [_AL2 -999 ~ 9999 41 Refer to the mode of Alarm mn
AL wa La ~
Pressey 2
Hysteresis of alarm ALH 0~ 9999 Ex. PV2(SV+AL1)—AL1 ON, 3
Pegees aan | DA Be ear eate jaan ocd 3
pose) WV
Flick mer [ 7 0~99 41> Range:0~99 sec
sane ] 0 2 oyele time of fick timer
Freee BET]
‘Seting Init Car 0- 9999 +> SVSSLH
maaan —] L400 2 Range of transmitter: O-SLH->
Press BET] ¥
‘Ouipat iit [eq 0~ 100% 41> Output volume =
Bae L209] Control output volume * ' Out
PessBe]
Process output volume | [__ Un 0~99.99 41> Display the output volume
zee Toe
Peake] 7
[ia selva seing) [“aSPH] 0~ 9999 1 cuneatar Vag rut ype wile apse ony
mxeRGnS | 1000 2> ax io va wiles ioe CuertrVoloerputpe wil be apsere en
RNB L2 ‘2> Mo input vabe wi be tensed inf the ASPL
PossBeT] OY
Frees eomenathaae | [61a 0-99.99 41> Range: 0.00~ 99.998
aepameiwae | [om
PressET)
Healer break eeting | [__Hb] 0~99.99 41> Range: 0.00 ~ 99.994
eam ia] — [100 2B "Cty, Range: -9.99 ~ 99.99 3
Crm aR L200] 2> Offset of CT current 2
rea] &
CTrignintseting | [Cth 0-99.99 ‘> Range:0.00~ 99.99 §
Crake T2009 2 To set the max.CT current cy
rape] A
Ramp control seting | [_1AP| 0 ~ 9999 4> Range: 0 ~ 9999 °C or "F / minute 2
amiaaih Lo 2> Rap=0- Without Ramp contel function &
reobel 8
Min, ouipulvolime seting ] [Lo 00% 41> Range: 0 ~ 100% 3
aaa Lo > Seiting of min. output volume 5
rasaBSeT]3 out . Ps
Sots sateg—] [572 900-0999 (SVB, = Oot sola finctan
3 PV, = “SV2, :Oulput volimeis
cont
by PIDFOTEK
Fuzzy + PID Intelligent Temperature Controlle
I Mode of alarm / #486483¢ [NT-CIC1)
a
A
cy
3
3
= : :
Fy SS a no apc
lan 1
R a — |) || —
~ 8 | aon 2 10 | zon ee || ry
= = fae 3
£ ALI ON “ALS OF : ALLOW :
Nsoh_1 ial a a ——F a a —
6 ACT 16 al 17 ra
a 19 | Non-used 20 TERT
ort pol i
ea sami
na = Ar i
a TL | 2 | wen - - 23) zy
net a na _ wo
* eecrimie— | | esta ae— |% | oSartatahas
4. TALES, :1= ON tine of AL2 for cooling, OFF tie is contlled by PID.
2. TALH, : Hysteresis of alarm. Ex. PV=(SV+AL1}-+AL1 ON, PV<(SV*ALT-ALH)-ALI OFF
3, "tau = Process time of tr, if tnuztnr , + AL2is tuned ON or OFF
i Mode of alarm / g83848zt [NT-J_1-CT & eTC-48 & NT-22)
7ST a Ce)
Fa
S Aion = —_ L108
: Aon a10y ——
id 3 = 4 5
5 Sy Sv SHAT mG a
3
| tery 7 | MtoN psc 5 Now
i Bean Sv SrA v-A SY Se
°
8
Aion 4 ALON Feria anes p>
p 8 q- | aoa " z
S Wa 8 wT Way 8 BHA 37 ana
z
41> TARE 11 :t= ON ime of AL fr cooling, OFF tm is contolled by PID.
2> TALH, :Hysteesis of alarm, Ex: PV2 (SV#AL1) -»AL1 ON ; PV< (SVFAL1-ALH) ALI OFF
35 NT-220-CT:HB alarm output is ALI
45 NT-48=-CT;HB alarm outputs AL2
2
aFOTEK
Fuzzy + PID Intelligent Temperature Controller
Connection gram Re
waone path,
poy or
= eae
Prem)
=o
oc =a
2
a
A
rc)
3
=
Ei
no [Con]
ey Duerse
Se] T= [ene [ee _— TT Be] [=| e] [p=] =
13 [4 [oe [ve [7 [oe | [ao | [a 13 [oe [8 [re [v7 [ve] [a0 [2 [ae fs [ae
BS85 Putate| 7] Cpa? R805 pater 7]_Oupat2 TET nna
seslomma| AA [ A Power Keira edpal_ALt[ Az [seneorepat
eel tlele We} ] 415 on
Tie fon hs eal ae [Fe +[=
= [Siais, +[= {es
lear | lemiramt ena sesnc] Ooms aa sass WJ
ae aa eae mte| Cea Sey
Bim Ces De) Bim Chotoabono bb)
ree caro
fe]+[=[™] "| [|v Fon] _[~[~
oy 75-405 [patarel7]_Oupet2_[ “Tet nou
Tae Pome Powaladp]_ALT[ A [Sersornpat
TTF TT2]s[«[2le[7]* [elon ]a
[el anno ie foe
o! fet=1 T+1= 3
exiome anc] Benne ne ES
00 | Ble Cem OO FS
cy
i Attachment / BE ry
8
FI
cS
O
u
3Por om
id
a
R
zp
i
FE
Gi
FOTEK
PID + Fuzzy Communication module
i Outline dimension / 9+]
a
Cuersen!
Cue
Specification may be modified without notice in advance. (2015/5/5)
FOTEK
OBA 'E BR AL Ay AIR a
FOTEK CONTROLS CO., LTD.
FoTEK 20155
B48