ETL600 R4
Technical Data
ETL600 R4
System data
Operating mode 2-wire frequency duplex
Single Side Band with suppressed carrier (SSB)
Modulation Multi-carrier modulation with trellis coding and forward error correction
Single step frequency conversion with Direct Digital Synthesis (DDS)
Nominal bandwidth 2, 2.5, 4, 8, 12, 16, 20, 24, 28, 32 kHz (each direction)
Edge frequencies at multiples of 500 Hz
IEC 60495, IEC 60834-1, IEC 60950-1, IEC 61000-6-2, IEC 61000-6-4
Standards compliance
(EN 55022 / CISPR22, Class A)
ETL600-050: 50 W / +47 dBm
Nominal transmit output power (PEP) ETL600-100: 100 W / +50 dBm
The output power may be decreased via user interface program (HMI) in steps of 1 dB
24 to 1000 kHz for nominal bandwidth ≥ 4 kHz
RF frequency range
24 to 500 kHz for 2 kHz nominal bandwidth
Nominal output impedance 75 Ω unbalanced (150 Ω balanced as option)
Return loss in the transmitter band ≥ 10 dB according to IEC 60495
Tapping loss ≤ 1.5 dB according to IEC 60495
Image rejection ≥ 75 dB
AGC (Automatic Gain Control) 40 dB dynamic range
Receiver sensitivity -30 dBm Pilot level at the RF input
Receiver selectivity > 65 dB / > 75 dB (for nominal bandwidth > 2 kHz) at 300 Hz / 4 kHz from the band edges
> 55 dB / > 65 dB (for nominal bandwidth = 2 kHz) at 300 Hz / 2 kHz from the band edges
Power supply -48 VDC +20/-15% (other on request)
Power consumption Normal operation @ 75 Ohm Dual tone modulation PEP @ 75 Ohm
ETL600-050 135 / 145 / 155 W (1 / 2 / 3 APLC channels) 175 / 185 / 195 W (1 / 2 / 3 APLC channels)
ETL600-100 210 / 220 / 230 W (1 / 2 / 3 APLC channels) 280 / 290 / 300 W (1 / 2 / 3 APLC channels)
Free changeover contacts
• System alarm / cabinet alarm
• Hardware alarm
Alarm relay outputs
• Link alarm
• Interface alarm
• Warning
2600 time-stamped alarm and manipulation events, stored in non-volatile memory
Event recording
Clock synchronizing input for IRIG-B available
Ambient conditions
Operation
IEC 60721-3-3, Class 3K5
Climatic conditions Temperature range Within specification: -5 to +55 °C
Humidity ≤ 95%, < 28 g/m 3, non-condensing
Mechanical conditions IEC 60721-3-3, Class 3M1
Vibration and shock IEC 60068-2-6, ICE 60068-2-27
Transport
IEC 60721-3-2, Class 2K4
Climatic conditions Temperature range -30 to +70 °C
Humidity ≤ 95%, < 28 g/m 3, non-condensing
Mechanical conditions IEC 60721-3-2, Class 2M1
Vibration sinusoidal IEC 60068-2-6
Shock and free fall IEC 60068-2-27, IEC 60068-2-32 0.25 m / equipment is packed
Storage
IEC 60721-3-1, Class 1K5
Climatic conditions Temperature range -30 to +70 °C
Humidity ≤ 95%, < 28 g/m 3, non-condensing
Mechanical conditions IEC 60721-3-1, Class 1M1
Dimensions and weights
19’’ wide conforming to standards IEC 60297 and DIN 41494
Equipment subracks 6 units high, 1 unit per equipment for earth rail and cover plate with label
(1 unit = 44.45 mm)
Dimensions / weight Height Width Depth * Weight * without front cable connectors
ETL600-050-1 308 mm 482 mm 301 mm 13 kg and module ejection handles
ETL600-050-2 575 mm 482 mm 301 mm 16 kg
ETL600-100-2 575 mm 482 mm 301 mm 20 kg
Audio frequency services
Transparent transmission of analog voice-frequency signals such as band limited speech with superimposed teleoperation, VFT-
Application
modems, facsimile, external teleprotection
• 0, 1, 2 or 3 channels 300 Hz to 3720 Hz in 4 kHz bandwidth each, or
• 3 channels of 3.2, 2.4 and 2.4 kHz bandwidth respectively, in 8 kHz total bandwidth
Number of AF channels • 1 channel of 2.0 kHz or 2.5 kHz bandwidth, for single purpose teleprotection
and service telephone
• 1 channel of 2 kHz, in conjunction with a 2 kHz or 6 kHz DPLC channel
Frequency offset ≈ 0 Hz
Up to 16 (depending on available broadband modem bandwidth and on interface requirements of other services to be deployed in
Number of compressed voice channels
the same terminal)
Telephony services
Analog speech
Telephony services Depending on configuration either:
• Point-to-point hotline / 2-wire remote subscriber / 4-wire remote subscriber
• 4-wire PAX connection with E&M signaling
• 2-/4-wire PAX connection with E&M signaling and hybrid control
• Transit mode for E&M wire
• Service phone (available once per AF channel)
Number of analog speech channels At most one in each AF channel
• 2.0 kHz to 3.4 kHz, programmable in steps of 200 Hz, limited by AF channel bandwidth
Speech low-pass filter cut-off frequency
• 1.6 kHz for nominal bandwidth of 2 kHz (used exclusively for service telephone)
Signalization DTMF-, MFC and Pulse-Code-Dialing
Speech limiter +3 dBm0
Speech compandor According to ITU-T G.162; configurable to “Off” or “On” (either permanent or enabled/disabled via control input)
Digital speech
Depending on configuration either:
• Point-to-point hotline / 2-wire remote subscriber / 4-wire remote subscriber
Telephony services
• 4-wire PAX connection with E&M signaling
• Services phone (available once per terminal)
Up to 16 for ETL600-050-2, ETL600-100-2
Number of digital speech channels
Up to 12 for ETL600-050-1
Speech low-pass filter cut-off frequency 2.0 kHz to 3.4 kHz, programmable in steps of 200 Hz
Signalization DTMF- and Pulse-Code-Dialing
Modes Voice and FAX 4.8 kbps (automatic FAX detection)
Data rate 5.3 or 6.3 kbps, programmable
Compression algorithm MP-MLQ / ACELP according to ITU-T G.723.1
Echo canceller According to ITU-T G.168
Digital transit
Number of transit connections Up to 5 (i.e. 6 telephony links in a chain)
Number of links per substation Up to 5 (i.e. speech channel can be forwarded in 1 out of 4 possible directions)
Telephony ports
4-wire PAX interface with E&M Analog speech Digital speech
Impedance 600 Ω, balanced 600 Ω, balanced
Input level range -20 to +4 dBm -20 to +5 dBm
Output level range -20 to +5.5 dBm -20 to +8 dBm
2-wire subscriber interface (FXS) Analog speech Digital speech
Impedance 600 Ω, balanced programmable (resistive and complex)
Input level range -17 to +4 dBm -17 to +4 dBm
Output level range -17 to +1 dBm -17 to +1 dBm
Ringing frequency 25 or 20 Hz, programmable 16, 20, 25, 50 or 60 Hz, programmable
50 Vrms open circuit; 50 Vrms open circuit;
Ringing voltage
≥ 36 Vrms across 2.333 kΩ load ≥ 36 Vrms across 2.333 kΩ load
DC loop voltage 48 VDC ± 15% open loop 48 VDC ± 15% open loop
2-wire PAX interface (FXO) Analog speech Digital speech
Impedance 600 Ω, balanced programmable (resistive and complex)
Input level range -17 to +4 dBm -17 to +4 dBm
Output level range -17 to +1 dBm -17 to +1 dBm
Ringing voltage detection range 20 to 130 Vrms / 17 to 55 Hz 20 to 130 Vrms / 15 to 65 Hz
Service telephone Analog speech Digital speech
Connector for 2-wire telephone set RJ11 on front panel RJ11 on front panel
Teleoperation
Number of ports Up to 20
Impedance 600 Ω, balanced
Input level range -20 to +4 dBm
Output level range -20 to +8 dBm
Transit filters
Number of filters Up to 20
Standard filters Programmable bandpass filters with cut-off frequencies selectable in steps of 60 Hz
• Bandpass filters for teleoperation band above speech 2000, 2200 or 2400 Hz, or
Group delay equalized filters
• 3600 Hz lowpass filter
Data services
Broadband data (MOD600)
Application Transmission of high-speed / high-capacity data in bandwidth of 2 kHz, 4 kHz or higher
Number of broadband modems 1
Transmission bandwidth 2, 4, 6, 8, 12, 16, 20, 24, 28, 32 kHz
9.6, 11*, 12, 14.4, 16, 19.2, 24, 28.8, 32, 36, 38.4, 40, 48, 56, 64,
Programmable data rates 72, 76.8, 80, 96, 112, 128, 144, 153.6, 160, 192, 224, 256, 288, 307.2, 320 kbps
* available only for DPLC bandwidth 2 kHz
Efficiency (data rate / bandwidth) Typically 2 bps / Hz at 15 dB SNR to 10 bps / Hz at 45 dB SNR (for BER = 1E-06)
According to 5 user-selectable data-rates (fallback / fall-forward)
Dynamic speed adaptation (DSA)
Not available for DPLC bandwidth 2 kHz
Narrowband data (NSK600)
Data transmission in bandwidth of less than 4 kHz, in point-to-point or
Application
point-to-multipoint applications (e.g polling SCADA)
≤ 4 for data rates ≤ 4800 bps, or
Number of narrowband modems
≤ 3 for data rates ≤ 9600 bps
Programmable bandwidth and data rates: 200 Bd 200 Bd 1200 Bd 1200 Bd 2400 4800
100 Bd 600 Bd 9600 bps
narrow wide V.23 narrow bps bps
Operational data rate [bps] ≤ 150 ≤ 225 ≤ 300 ≤ 600 ≤ 1200 ≤ 1200 2400 4800 9600
Data format transparent trans- trans- trans- trans- trans- trans-
UART UART UART
parent parent parent parent parent parent
Nominal bandwidth [Hz]
240 360 480 960 2400 1640 840 1680 3360
(= channel spacing)
Center frequency steps [Hz] 60 60 60 60 n.a. 1660 60 60 n.a.
Equalizer Static APLC channel equalizer Static or adaptive
1 x 1200 Bd (asynchronous, transparent), or
Max. data rates above 2 kHz speech band
2 x 2400 bps, or 1 x 4800 bps (asynchronous, UART)
Multiplexer (MUX600)
Application Time-Division Multiplexing of a number of data channels into an aggregate data stream
Number of channels 10 for data ports / 16 for compressed voice channels
Multiplexing method TDM, with data flow control and speed adaptation according to aggregate capacity
Data ports
V.11 ports
Number of V.11/X.21/X.24 ports 1 or 2 (option), depending on configuration
Data rates See broadband data
• From ETL600
Clock direction
• Codirectional
V.24 ports
2 or 4 (option), depending on configuration;
Number of V.24/RS-232 ports
with optional port sharing and jabber timeout for point-to-multipoint operation
With MOD600: 200, 300, 600, 1200, 2400, 4800, 9600 or 19200 bps
Data rates
With NSK600: according to selected NSK600 channel
V.24 port sharing device
Number of shared ports Up to 4
Jabber timeout 100 s; can be disabled
Application Sharing of one data channel by several RTUs (Remote Terminal Units)
LAN ports (option)
Number of LAN ports 3 electrical and 1 optical (with automatic laser shutdown ALS)
Programmable data rates See broadband data
Electrical: 10/100 BaseT (shielded twisted pair, STP), connector type RJ45
Connector
Optical: 100 Mbps (SFP 850 nm MM or 1310 nm SM), connector type LC
Physical layer Auto or manual negotiation (full/half duplex and 10/100 Mbps)
Link layer Conforms to IEEE 802.3 / Ethernet II
4-port switch (layer 2) or IP router (layer 3), SNMP, HMI over LAN
VLAN support according to IEEE 802.1q
LAN600 services
Link Fault Pass-Through (LFPT)
Up to 16 static routes, 4 priority queues
TCP/IP header compression according to RFC 1144
Data compression (configurable)
UDP/IP and RTP/UDP/IP header compression according to RFC 3095
Digital transit ports (option)
2 electrical, connector type RJ45,
Number of digital transit ports
to daisy-chain up to 5 ETL600 terminals by means of 1:1 Ethernet cables
Teleprotection (NSD600)
Application Transmission of protection commands for line and objects protection
Number of units 1 or 2 integrated NSD600, depending on configuration in AF channels (APLC) and/or broadband channel (DPLC)
4 simultaneous commands, simultaneously transmitted,
individually configurable for blocking, permissive or direct tripping;
Number of commands
Single purpose teleprotection NSD600 in the 2 kHz APLC channel:
3 independent commands (as above) and 1 prioritized command (for direct tripping)
Noise (continuous or impulsive), speech and sweep tones,
Secure against
DTMF (CCITT 48430 or ITU-T Q.23) in-band signaling
Bandwidth requirement Nil; command signal transmission in-band (alternate purpose, with signal boosting)
Guard signal ETL-pilot signal, or own guard signal above speech band 2000, 2200, 2400 Hz
Processing of received signal Adaptive (to prevailing channel condition, always ensuring shortest transmission times)
Number and type of inputs 4 optocoupler per teleprotection interface
Method of tripping Contact and battery, or dry contact
Voltage ranges 24 to 250 VDC, selectable in 4 ranges
Number and type of outputs 4 solid state relays and 2 mechanical relay contacts per teleprotection interface
5 to 250 VDC nominal
Tripping voltage ≤ 1 A carry / 2 A peak solid state
Tripping current 5 A carry / 20 A peak mechanical relay
Command and alarm assignments to I/O ports,
Command pick-up times, hold times, duration monitoring,
HMI configurable
State of command outputs during link alarm,
Alarm and unblocking level thresholds
Test facilities Manual or periodic loop test every 1, 3, 6, 12, 24 hours
2600 time-stamped command events, stored in non-volatile memory
Event recording Clock synchronizing input for IRIG-B available
Counters for Tx/Rx commands, unblocking condition and start signal (max. count 1E+09)
Teleprotection performance
Application Blocking Permissive tripping Direct tripping
APLC 4 = 4 kHz; APLC 2 = 2 kHz APLC 4 DPLC APLC 2 APLC 4 DPLC APLC 2 APLC 4 DPLC APLC 2
Nominal transmission time T0 1) ≤ 10 ms ≤ 11 ms ≤ 11 ms ≤ 11 ms ≤ 12 ms ≤ 12 ms ≤ 12 ms ≤ 13 ms ≤ 14 ms
Security Puc < 1E-04 < 1E-03 < 1E-03 < 1E-06 < 1E-06 < 1E-06 < 1E-09 < 1E-09 < 1E-09
Dependability Pmc < 1E-03 < 1E-03 < 1E-03 < 1E-03 < 1E-03 < 1E-03 < 1E-04 < 1E-04 < 1E-04
(SNR = 6 dB) Tac 1) 14 ms 15 ms 17 ms 17 ms 17 ms 19 ms 22 ms 22 ms 30 ms
1) Valid for the solid state command outputs, add 4...8 ms for the relay contact command outputs
User interface program (HMI600)
Hardware and OS requirements PC with Windows Vista / 7 / 8 / 10
RS-232 / 9600, 19200, 57600 bps;
Port for connection of service PC USB with optional interface converter;
Ethernet port as option
Integrated testing aids
Channel equalization Automatic, with graphical display of channel amplitude response
Spectrum analyzer For graphical display of signal spectra in AF channels
Auxiliary signals generation For tuning, testing and commissioning
Address range for 65000 terminals;
Equipment settings, status monitoring and firmware download locally and remotely via Embedded Operational Channel (EOC) or via
LAN600;
Element management Alarm polling facility for all terminals in the network, via EOC and all supported communication media (including dial-up telephone
modem connection or Intranet/Internet access using IP with optional direct LAN connection
SNMP alarm messages can be collected by a network management system;
Support of mixed ETL500 / ETL600 networks
Hitachi Energy We reserve the right to make technical We reserve all rights in this document and in
marketing-update@[Link] changes or modify the contents of this the subject matter and illustrations contained
© 2022 Hitachi Energy. All rights reserved. document without prior notice. With regard therein. Any reproduction, disclosure to
to purchase orders, the agreed particulars third parties or utilization of its contents – in
shall prevail. Hitachi Energy Ltd. does not whole or in parts – is forbidden without prior
accept any responsibility whatsoever for written consent of Hitachi Energy Ltd.
potential errors or possible lack of information
[Link] in this document. 4CAE000463