Translated from Chinese (Simplified) to English - www.onlinedoctranslator.

com

Provincial Bureau HiPath 3800 technical training

Written by: Liu Lei

Summary:

1. System basic training:

Main explanationHiPath 3800systems and boards.

2. Hardware basic training:

Mainly explainedHiPath 3800hardware installation.

3. Software debugging training:

Mainly explainedHiPath 3800programming.


1. System basic training

1.1 HiPath 3800system introduction

HiPath3800The digital program-controlled switch is the latest generation of the German Siemens company that has been introduced to the market to provide communication services for small and medium-sized enterprises.IPPBX

functional multimedia switch, which can provide optimal and diverse digital, analog andIPTrunk and subscriber line interfaces.

HiPath 3800IPIntegrated systems provide mid-sized businesses (up to1000users) to provide reliable

voice communication. ifHiPath 3800Used as a stand-alone system, it can support up to500a work point.64indivualHiPath 3800The system can

Transparent networking.HiPath 3800It is a new generation of high-end hardware platform with improved performance. accessibleHiPath ComScendofor all departments

The system provides rich functions. existHiPath3000/4000In the network, it can be used asHiPath4000Self-healing remote module. Mobile in wireless

In the mobile voice application, you can useDECTandVoWLANTwo solutions are implemented, among whichVoWLANfor the true senseIPlayer solution

plan.

HiPath3800The system provides users with long-distance work, mobile communications, multimedia applications,CTIsolutions and other new application areas.

method.

HiPath3800Using a unified software platform can adapt to the functional needs of companies of different sizes. Its digital phones adopt a unified

optipointseries, which supports optimal economical routing, withCornetN,Q-sigand other kinds of networking signaling, which can provide development for user applications.

interface, with comprehensive wireless communication solutions, comprehensiveLANsolution.

HiPath3800The switch processor usesIBMDedicated communication processing chip, the traffic volume of each port is0.54Er( lIreland) ,BHCA(busy

(hourly call volume) value is25000.

Due to the large-scale integration of modern communication, microelectronics and computer technology, the device has the following characteristics:

- Small size, strong processing power, and various interfaces.

- haveISDNfunction, availableDSS1,CORNET,2B+Dand other signaling.

- Easy to operate and easy to maintain.

- It has strong troubleshooting capabilities, no fan, and low power consumption.

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
1/39
1.2 HiPath 3000V7.0System configuration and capacity:

System HiPath 3800

Mixed configuration (TDM+IP)Maximum User[TDM=Analog phone + digital phone + phone connected to the adapter + wireless phone +IPphone] 500

384
Stations/work Point clients

Maximum number of analog + digital terminals

Impersonate user 384

digital user 384

passoPtiPointNumber of users added by phone adapter 116

IPUser number 500

Wireless extension user 250

wireless base station 64(SLC16/N)

Total CO and network trunks/TDM+IP 250

120
Trunks

Analog trunk

digital relayS0.S2M 180

Total network trunks CorNet-IP 128

HiPath HG1500 boards(HG1500gateway card) 8

Gateway channels to the system 128

V.24 interfacesserial port 2(2 x 9-Pin)

1.3 HiPath 3000V7.0System power consumption, size and weight:

Maximum system values HiPath 3800

upsPower consumption 430W

Line voltageLine voltage 100~240VAC

ACLine frequency 50~60 Hz

Chassis sizemm(high×Width×deep) 440×430×490

Heightunitsfor 19" cabinet assembly(19inches cabinet assembly dimensionsU) 11

Weight kg(weight) twenty two

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
2/39
1.4Interface distance

Telephone Interface-to-Interface Ranges(with JY(ST)2×2×0.6,0.6mm diameter)

Telephone interface Range in m Loop resistance in ohms

ISDN-S0point-to-point(ISDNpoint to point) <600 156

ISDN S0extended bus connection(ISDNExtended terminal distance) <400 104

<60
twenty one

for the HiPath 3800 board STMD3(Q2217)


ISDN S0bus connection
<120
for all other S0board

ISDN-S0wall outlet to terminal <10 ˉ

Analog users(emulated terminal) <2000 520

UPO/Eexchange to host(master)(digital terminal to host) <1000 230

UPO/Ehost to client(master/slave)(digital terminal to digital terminal) <100 twenty three

1.5 HiPath 3800introduce

1.5.1 HiPath 3800structure

base on needsHiPath 3800There are two options for use:

- lSingle cabinet system basic cabinetB.C.

- lTwo-cabinet system base cabinet plus an expansion cabinet (BC+EC)

Single cabinet Double cabinet Dimensions

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
3/39
HiPath 3800It is a modular design. The motherboard must be installed in the sixth slot of the main cabinet. The main cabinet has a total of10slots, nine of which

are free slots; the expansion cabinet and the main cabinet have the same size, and the expansion cabinet has a total14slots, the seventh slot is not used, so

The free slots for expansion cabinets are13, total of main cabinet and expansion cabinettwenty twofree slots, maximum installationtwenty twoboard.

HiPath 3800main cabinet HiPath 3800expansion cabinet

9free slot

13free slot

Power supply modular design

1.5.2The power supply adopts modular design

The power supply adopts a one plus one cold backup design. Normal use of two power modules in the main cabinet can work normally, and the third power module can work normally.

The module is used as a backup power module. When other power modules fail, it automatically replaces the faulty module and will not cause the system to fail due to power module failure.

Affect. The expansion cabinet can be installed with up to four power modules. In the maximum configuration, three power modules can work normally, and the fourth module can

Used for backup modules. The following table is a reference table for how many power modules to use under what circumstances. When using the backup battery, each cabinet is

Under normal use standards, one more power module is required.

Number ofperipheral PBXXX,STMI2,SLMA Number ofLUNA2s


LUAN2Basic configuration of power supply
boardsper cabinet and/or SLCN available required per cabinet
<5 no 1

Basic cabinet <5 yes 2


Basic cabinet ≥5 no 2
≥5 yes 2
<5 no 1
<5 yes 2

Expansion cabinet ≥5 no 2
expansion cabinet ≥5 yes 3
≥10 no 3
≥10 yes 3

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
4/39
1.5.3 HiPath 3800Board

we willHiPath 3800The boards on the system are divided into three categories according to their usage types: control and function modules, relay modules and user modules.

module.

user module Control and function modules Relay module

IVMN8 CBSAP DIUT2

IVMNL CMS DIUN2

SLMAE IMODN STMD3

SLMAE8 LIMS STMI2

SLMO2(SLMO24) LUNA2 TMANI

SLMO8 MPPI TM2LP

STMD3 REALS TMEW2

STMI2 PFT1/PFT4

PDMX

1.5.3.1Control and function modules

1.5.3.1.1Main control board (CBSAP -CcentralBeardSenergyAaccessPplatform)

The main control board is responsible forHipath 3800The central control and switching functions of the system. This card can expand the corresponding functions by installing functional modules.

It can only be installed in the sixth slot of the main cabinet.

- The red and green lights are the two running indicators on the motherboard. During normal operation, the green light flashes. When the red light is on, it indicates a fault.

- RESETThe button is under the light. This button has two functions.

- Restart the system, operation method: press and release, the system will restart

- Initialize the system, operation method: press and release, when the light flashes, press and hold9Release it in seconds and the system initializes.

- The yellow position is for installationMMCmemory card.

- SERVERSThe serial port is used to connect to the computer for maintenance purposes

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
5/39
- APPLICATIONThe serial port is used to connect printing devices or applications

- LAN1When the green light is on100MAccess, when the yellow light is on10Maccess,LAN2Do not use

①. Expansion daughter card

● CMSClock card (optional)

● MMSmultimedia card

● IMODNRemote maintenance card (optional)

● LIMNetwork interface module (for motherboards without integrated network port) (optional)

● MPPI music on hold1(optional)

Note: Users need to have backup music during call transfer. This card is used to connect external music sources, such asCD Player.

② .V.24interface1(Sub-D 9pin interface)

● Service (X50) =Connect to maintenance terminal

● Application (X51) =Connect to other applications such as printers or billing systems

Note:V.24Interface: used to connect the maintenance terminal and billing system, which can be accessed from the front side of the basic cabinet (remove the cover first)CBCPRThe first one onV.24interface(9

NeedleSUB-Dsocket). The second one can be accessed through the base panel of the basic cabinetV.24interface(25NeedleSUB-Dsocket).

③.CBSAPPanel switches and indicators

●Reset/reloadswitch:

‒ Press the reset switch less than5STime = Restart switch

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
6/39
‒ Pressing this switch is greater than5Stime = reload factory data (FailThe indicator light goes out to indicate that reloading is in progress)

● twoledlight indicationCBSAPCentral control circuit board status:

‒ runled(green) = showCBSAPCentral control circuit board normal status signal

‒ Faultled(red) = fault

● twoledLights indicate network interface module status:

‒ LED1:

‒ green =100MbpsLink

‒ yellow =10MbpsLink

‒ Flashing = running status

‒ LED2 (green):

‒ bright = full duplex (FDX)

‒ Off = half duplex

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
7/39
CBSAPrunledStatus meaning

ledDisplay state meaning

destroy no power

Bright The reset switch is temporarily in the pressed position

destroy The reset switch is pressed for more than5Second(ledTurns off to indicate the system is starting to reset)

Bright System boot

destruction continues0.1s Loading operation:SDRAMmiddleAPS, load software and card data

Flashing on0.5s/destroy0.5s Normal working status (no load1)

Flashing on0.1s/destroy0.1s MMCDismantled or malfunctioning

Note: The flashing rhythm depends on the load size. The greater the system load, the slower the flashing rhythm.

1.5.3.1.2 MMC

Multimedia card (Multi Media Card) is a plug-in memory card for the central control circuit board, withCDBbackup and for certain countries

specialized in producing application processor software (APS), used to store system software and programs.

Note: Disassembly and replacementMMCThe system must be powered off before proceeding. Please note that theMMCMaybe it can only be done bySiemens AGManufactured multimedia card replacement. Cards not yet released

Perhaps have a different internal structure, which is useful for transient access and some other functions such asCDBbackup andAPStransmission) has an impact.

1.5.3.2Relay module

1.5.3.2.1digital relay moduleISDN 30B+D(DIUN2-DdigitalIInterfaceUnit ISDN)

two way30B+DofISDNRelay board for connectionS2Mrelay, or digital relay network.

2digital trunk board, providing2indivual30B1+D2digital trunk interface

1.B-channel-BA channel is also called a bearer channel (Bearer Channel), is a rate per second used for voice, video, data or multimedia transmission64KBChannel. These

channels can be aggregated to provide higher bandwidth usage.

2.D-channel-DChannel is also calledDeltaChannel, transmission speed is per second16KBor64KB, mainly used to transmit signaling between switching devices. This increasesISDN security

because the control and data channels are separate.

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
8/39
DIUN2-LEDStatus meaning

red green state deal with

The board has no power or is not inserted into the card slot correctly.

destroy destroy Check that the board is inserted into place.


Board failure.

The power supply of the board is normal and self-test is performed.

Replace the board.


BoardledThe light status remains unchanged and the board is defective (self-test failed).

Software loading did not complete successfully.

Bright destroy Replace the board.


The board is defective.

The board found an error. Check whether the maintenance software is set incorrectly.

The board is not activated (the board is found to be unsuitable when testing the loop) or the maintenance software settings are incorrect. Make sure the maintenance software settings are correct and replace the board.

flashing destroy Start loading the software.

destroy Bright The board self-test is completed. The board is working normally (the green light remains on).

destroy flashing At least one channel is active.

1.5.3.2.2Analog display relay module (TMANI)

used to connect8This module supports reverse polarity billing and the caller ID function of the analog trunk.

1.5.3.2.3Analog relay module (TM2LP)

used to connect8This module supports reverse polarity billing and does not support the caller ID function of analog trunks.

1.5.3.3user module

1.5.3.3.1To display the analog extension module (SLMAE)

twenty fourroad(SLMAE)'s analog extension module is used to connect to analog extensions. This module has the following functions:

- supportCLIPFunction, supports caller ID on analog phones

- supportDTMFDial-up and analog phone use

- Comes with motherboard65VThe bell flow

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
9/39
This board can only be used in6.0and6.0used on future systems.

SLMAE-LEDStatus meaning

red green state deal with

The board has no power or is not inserted into the card slot correctly.

destroy destroy Check that the board is inserted into place.


Board failure.

The power supply of the board is normal and self-test is performed.

Replace the board.


BoardledThe light status remains unchanged and the board is defective (self-test failed).

Software loading did not complete successfully.

Bright destroy Replace the board.


The board is defective.

The board found an error. Check whether the maintenance software is set incorrectly.

The board is not activated (the board is found to be unsuitable when testing the loop) or the maintenance software settings are incorrect. Make sure the maintenance software settings are correct and replace the board.

flashing destroy Start loading the software.

destroy Bright The board self-test is completed. The board is working normally (the green light remains on).

destroy flashing At least one subscriber line is active.

1.5.3.3.2Digital extension module (SLMO2/SLMO8)

supply8road(SLMO8)andtwenty fourroad(SLMO2)ofUPO/EDigital interface for connecting to Siemens digital telephones.

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
10/39
SLMO2/SLMO8-LEDStatus meaning

red green state deal with

The board has no power or is not inserted into the card slot correctly.

destroy destroy Check that the board is inserted into place.


Board failure.

The power supply of the board is normal and self-test is performed.

Replace the board.


BoardledThe light status remains unchanged and the board is defective (self-test failed).

Software loading did not complete successfully.

Bright destroy Replace the board.


The board is defective.

The board found an error. Check whether the maintenance software is set incorrectly.

The board is not activated (the board is found to be unsuitable when testing the loop) or the maintenance software settings are incorrect. Make sure the maintenance software settings are correct and replace the board.

flashing destroy Start loading the software.

destroy Bright The board self-test is completed. The board is working normally (the green light remains on).

destroy flashing At least one subscriber line is active.

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
11/39
2. Hardware basic training

2.1 HiPath 3800Operating environment

- Room temperature: +5...+40°C (41 ... 104°F)

- Absolute humidity:2-25gH2O/m3

- Relative humidity:5-80%

- Maintain air convection and smooth ventilation

- The system needs to be used in a fixed location

2.2 19inch standard cabinet installation

2.2.1 Hipath 3800The system can be divided into:

- Single cabinet system (basic cabinet:B.C.1)

- Two-cabinet system (base cabinet plus an expansion cabinet:B.C.+EC2)

1.Basic Cabinet.host (9free slots)

2.Expansion Cabinet.Auxiliary engine(13free slots)

2.2.2 Hipath 3800 19inch standard cabinet fixing:

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
12/39
2.2.3 Hipath 3800 19Inch standard cabinet dimensions:

Dual cabinet systemB.C.Cabinets andECThere should be at least one space between cabinets3Uheat dissipation space.

2.2.3System ground:

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
13/39
2.3 Hipath3800Board installation

2.3.1Before installing the board, you must understand the following:

(1)Hipath3800There are nine free slots on the basic cabinet (slots1to5and trough7to10) and the expansion cabinet have13free slots (slots1to

6and trough8to14).

(2)The motherboard is fixedly installed on the main cabinet.6slot, on the expansion cabinet7The slot is not allocated yet and cannot be used.

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
14/39
(3)Upon request, the main cabinet can be installed up to3indivualLUNA2Power supply modules, expansion cabinets installed at most4indivualLUNA2Power module.

Main control board

The yellow slot is from

by slot

Power Module

main cabinet

The yellow slot is from

by slot

Power Module

expansion cabinet

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
15/39
2.3.2Board installation and removal steps

- Push the board all the way along the slot, and then use a wrench to press the board inward. (As shown in Figure 1 below) .

- If the board needs to be removed, also use a wrench to hook the hole on the upper part of the board and push the board outward. (As shown in Figure 2 below).

- CBSAPBoard/LUNA2/MMCIt is not hot-swappable. Peripheral boards can be hot-swapped for reset.

Figure 1 Installation Figure 2 removed

2.3.3 Hipath3800Power module installation

2.3.3.1Installation and disassemblyLUNA2Power supply module

Confirm before installing the module

-Main power is off

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
16/39
-LUNA2The power module switch is locatedOFFLocation

2.3.3.2Installing and removing the front panel of the power supply module of the main cabinet

2.3.3.3Installing and removing the front panel of the power supply module of the expansion cabinet

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
17/39
2.3.4Backplane connection

Interface: connect

expansion cabinet

main cabinet

Interface: connect

main cabinet

expansion cabinet

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
18/39
2.3.5cable

2.3.5.1 24To the cable--SLMO8,SLMO2,SLMAE,TMANI,TM2LPLine order:

port TMANI TM2LP SLMO8 SLMO2/SLMAE

1 white/blue white/blue white/blue white/blue

2 white/orange white/orange white/orange white/orange

3 White and green White and green White and green White and green

4 white/brown white/brown white/brown white/brown

5 white/grey white/grey white/grey white/grey

6 red/blue red/blue red/blue red/blue

7 red/orange red/orange red/orange red/orange

8 red/green red/green red/green red/green

9 Red Brown

10 red/grey

11 Black blue

12 black/orange

13 dark green

14 black/brown

15 black/grey

16 yellow/blue

Do not use Do not use Do not use

17 yellow/orange

18 yellow/green

19 yellow/brown

20 yellow/gray

twenty one purple/blue

twenty two purple/orange

twenty three purple/green

twenty four purple/brown

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
19/39
2.3.5.2 V.24Cable sequence (CBSAP)

9-pole(Needle)-------9-pole(Needle)

2.3.5.2 2MCable sequence (DIUN2/ DIUT2)

15-pole(Needle) -------BNC×2/L9-75×2

# 1coaxial cable shield 1


2 and15Pin serial port#10core short circuit

3
4
5
6 and15Pin serial port#14core short circuit

7
# 2coaxial cable shield 8
# 1coaxial cable shield core 9
10 and15Pin serial port#2core short circuit

11
12
13
14 and15Pin serial port#6core short circuit

# 2coaxial cable shield core 15

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
20/39
3. Software debugging training

3.1useManager ESet up the system

3.1.1Open console steps

1.The maintenance computer uses the serial port with connectors at both ends.9Needle(female) maintenance cable is directly connected toHiPath 3800ofCBSAPplateSERVICE

port connection.

2.InstallManager EManagement software, the software version should be higher than or the same as the switch system version.

3.The software has no desktop shortcut by default.start→program→HiPath 3000 Manager E→HiPath 3000 Manager Estart up

Manager Emanagement software.

4.WillHiPath 3000 Manager ESend the shortcut to the desktop and double-click the maintenance software icon to start itManager Emanagement software.

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
twenty one/39
5.Enter the maintenance software interface

System default username and password:

username:31994

password:31994

6.If the physical serial port of the maintenance computer is notCOM1, need to set the serial port and baud rate (Options→Program options)

7.Click on the interface belowCommunication Setting, set the serial port and baud rate, and then click Apply

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
twenty two/39
Set interface type here

Set up the computer serial port here

Set baud rate here

8.Enter the console and clicktransferrbutton

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
twenty three/39
9.existTransferIn the properties window, selectRead/write databaseoption, clickSystem→PCbutton.

10.ClickSystem→PCbutton, popupLogon informationwindow, pointOK.

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
twenty four/39
11.ClickLogon informationwindowOKPress the button, and the maintenance software starts to download the switch data. The figure below shows the data download process.

Data download progress bar


Data download progress

12.Wait for the switch data download to complete,TransferThe progress of the blue bar in the download window is100%, clickTransferdownload windowOKbutton,

ClickTransferwindowClosebutton, closeTransferwindow to enter the switch maintenance interface.

Data download completed

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
25/39
13.The following figure shows the maintenance terminal disconnected from the switch.TransferDownload windowTimeThere is no countdown, because the hardware has not established a connection.

TimeCountdown, no pop-upLogon informationwindow to check the connection parameters and physical connection.

Connection not established

ClickCancel, check even


Connection parameters and physical connections

3.1.2View system board status (System-wide)

System-wide

system version

Slots and corresponding boards

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
26/39
3.1.3Extension settings (Setup Station)

Setup Station

Extension port type

Extension Number

Board model, slot and port

Extension usage status

Extension model and connection status

After entering the extension number, you can clickCheckCheck for conflicts

This window pops up indicating that there is a conflict in the number.

The specific conflicting number location

Check for number resource conflicts

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
27/39
3.1.4Extension related attributes (Stationview) - forced penetration (Flag status→Override class of service on)

Forced permissions

Select extension

Modify extension attributes in batches

The forced default function code is*62. To dial a busy extension from an extension with override authority, press *62You can forcibly interrupt a call on a busy extension to notify the other party to hang up.

OverrideForced penetration

Function code definition Double-click to modify the default function code

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
28/39
3.1.5Extension related attributes (Stationview)-Hotline(Activated features→Hotline)

chooseHotline
Select extension

chooseHotlinedestination

chooseSystem parameters→System settingSet the hotline destination, which can be set6different destinations.

chooseHotlineDestination serial number

fill inHotlineHead
local extension number

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
29/39
3.1.6Define digital phone (dispatch console) function keys

ClickSetup StationAfter that, selectKey programmingThe following picture appears: first select the phone to be defined, then select the function key to be defined, and then

Then set the function to be defined, and finally clickOKconfirm. The following two figures define the function key simulation trunk dispatch direct pass and the function key dispatch number deposit direct pass.

Choose to decide

righteous phone

Select the key you want to define

Set the function to be defined

chooseCallkey

Select relay

Set up add/remove key module

chooseVacant, refer to the phone

The description is to save the number for the function button

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
30/39
3.1.7Digital/Analog Trunk Networking (Lines/networking→Trunks)

Select a trunk group and unused channel points


Trunk channel number

arriveNONEGroup to avoid catching idle time

Double-click to set the relay board properties

Select the networking trunk board When data is connected, the line

Typetype will be displayed

set up2MRelay networking board properties (Parameter→ISDN flags), select signaling for ultra-high voltage substation networking.

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
31/39
Set the properties of the analog relay networking board (Parameter→MSI flags)

Ordinary analog trunk, if not enabled

Reverse polarity, must be canceled here

3.1.8extensionDIDset up

Select trunk group

Define trunk group out

Office calling number

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
32/39
3.1.9Set up economic routing

3.1.9.1Activate economic routing (Least cost routing→Codes and flags→LCR-flags→Activate LCR)

CheckActivate LCR
Activate economic routing

3.1.9.2ClickDial plan, through this table you can set dialing rules, routing tables, code sending settings, etc.

1.Define route name


3.Select routing table

2.Set up dialing rules

4.Define routing table

Corresponding relay group

5.Select routing table code issuing rules

6.Define route dialing permissions


Then, double-click to define the rule

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
33/39
3.1.9.2.1Set up routing steps

(1)Select an empty route and set the route name (NAME)

Route names must not be repeated or use Chinese characters.

(2)Set up dialing rules

, followed by dialing
a)The default setting of the code sending rule is full sending. "-"It is a separator, which can be omitted. The front of "-" is the outgoing code (commonly known as zone one).

. Right now:9-Xdial on behalf of9All after being eliminated9starting number.9For one area,XFor the second district.96116XXX,
Code issuance (commonly known as the second area)

That means dialing96116XXXAll after being eliminated96116beginning8digit number.96116610, which means dialing96116610Out.

b)The coding rules cannot be repeated!

(3)Select routing table

Routes with the same relay and coding rules can use the same routing table. Unless the routing table resources are insufficient, it is recommended to set one for each route.

routing table to prevent confusion and facilitate future routing table maintenance.

(4)Select the relay group corresponding to the routing table

There can be as many as multiple relay groups, that is, roundabout routing.

(5)Select routing table coding rules

It is recommended that different routes choose different coding rule serial numbers to facilitate maintenance. After selecting the coding rules, double-click this column to pop up the following window to define the coding rules.

Define the name of the coding rule, which is generally the same as the routing name.

Define coding rules,E1ATo develop a district,E2AFor the second

district.C2000To send the called number2000.

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
34/39
(6)Define route dialing permissions

Permissions1For low,15is the highest, corresponding to the extension authority(Classes of service), restrict extension dialing.

Extension permissions,1~15grade. Corresponding

routing authority, high level can dial the bottom

3.1.9.2.2Set analog trunk route alignment display

Analog trunk dispatch is dialed by defining phone function keys, and analog trunk waiting dialing needs to be set (Lines/networking→Routes→

Route prefix), that is, the dispatch console function keyledThe light flashes in response to an incoming call on the analog trunk.

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
35/39
3.1.10Extension group and bell settings

3.1.10.1Set extension group (dispatch group) (Incoming calls→groups/hunt groups)

Group No

Select the extensions included in this group

3.1.10.2Set analog trunk ring destination (Incoming calls→Ringing assignment per line)

Select analog trunk board Define daytime ring destinations

Define night ring destination

Just set the same ring destination for day/night. This is where the simulated trunk call comes in350Group,350Group dispatch console1001,1002Ring simultaneously.610

The group is established for digital trunking and also includes the dispatch station.1001,1002.

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
36/39
3.1.10.3Set Digit Trunk Ring Destination (System parameters→Flags→Node number)

Set the called number to eat, eat

Delete the set number, and the remaining

610, that is, the dispatch station group rings

3.1.11Console restarts the board

3.1.11.1chooseMaintenanceconnect

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
37/39
3.1.11.2Restart the board

chooseRestart/ReloadItem, firstRead card informationRefresh the system board information inReset-/reload cardSelect required

For the board to be restarted, clickActivate Reload CardYou can restart the board (Hard restartPlease restart the whole machine) .

2.Select board

1.Read board information

3.Restart the board

Shandong Shandong Huate Technology Co., Ltd. Information and Automation Division (Engineering Department) [email protected]
0531-85198696
38/39

You might also like