QICSGP

A76XX Series_
AT Command Manual
LTE Module

SIMCom Wireless Solutions Limited


SIMCom Headquarters Building, Building 3, No. 289 Linhong
Road, Changning District, Shanghai P.R. China
Tel: 86-21-31575100
[email protected]
www.simcom.com
A76XX Series_AT Command Manual_V1.04

Document Title: A76XX Series_AT Command Manual


Version: 1.04
Date: 2021.7.23
Status: Released

GENERAL NOTES

SIMCOM OFFERS THIS INFORMATION AS A SERVICE TO ITS CUSTOMERS, TO SUPPORT


APPLICATION AND ENGINEERING EFFORTS THAT USE THE PRODUCTS DESIGNED BY SIMCOM.
THE INFORMATION PROVIDED IS BASED UPON REQUIREMENTS SPECIFICALLY PROVIDED TO
SIMCOM BY THE CUSTOMERS. SIMCOM HAS NOT UNDERTAKEN ANY INDEPENDENT SEARCH
FOR ADDITIONAL RELEVANT INFORMATION, INCLUDING ANY INFORMATION THAT MAY BE IN THE
CUSTOMER’S POSSESSION. FURTHERMORE, SYSTEM VALIDATION OF THIS PRODUCT
DESIGNED BY SIMCOM WITHIN A LARGER ELECTRONIC SYSTEM REMAINS THE RESPONSIBILITY
OF THE CUSTOMER OR THE CUSTOMER’S SYSTEM INTEGRATOR. ALL SPECIFICATIONS
SUPPLIED HEREIN ARE SUBJECT TO CHANGE.

COPYRIGHT

THIS DOCUMENT CONTAINS PROPRIETARY TECHNICAL INFORMATION WHICH IS THE PROPERTY


OF SIMCOM WIRELESS SOLUTIONS LIMITED COPYING, TO OTHERS AND USING THIS DOCUMENT,
ARE FORBIDDEN WITHOUT EXPRESS AUTHORITY BY SIMCOM. OFFENDERS ARE LIABLE TO THE
PAYMENT OF INDEMNIFICATIONS. ALL RIGHTS RESERVED BY SIMCOM IN THE PROPRIETARY
TECHNICAL INFORMATION,INCLUDING BUT NOT LIMITED TO REGISTRATION GRANTING OF A
PATENT , A UTILITY MODEL OR DESIGN. ALL SPECIFICATION SUPPLIED HEREIN ARE SUBJECT TO
CHANGE WITHOUT NOTICE AT ANY TIME.

SIMCom Wireless Solutions Limited


SIMCom Headquarters Building, Building 3, No. 289 Linhong Road, Changning District, Shanghai P.R.
China
Tel: +86 21 31575100
Email: [email protected]

For more information, please visit:


https://www.simcom.com/download/list-863-en.html

For technical support, or to report documentation errors, please visit:


https://www.simcom.com/ask/ or email to: [email protected]

Copyright © 2021 SIMCom Wireless Solutions Limited All Rights Reserved.

www.simcom.com 1 / 483
A76XX Series_AT Command Manual_V1.04

Version History

Version Date Chapter Description


V1.00 2019.5.15 New version
5.2.9 AT+CGEQREQ
2019.5.20 Modify these commands
5.2.10 AT+CGEQMIN
9.2.9 AT+CNMI
2019.5.22 14.2.1 AT+CHTPSERV Modify these commands
14.2.3 AT+CNTP
2.2.15 AT&W
2019.6.5 Modify these commands
2.2.16 ATZ
2.2.10 AT&V
9.2.4 AT+CSCA
9.2.6 AT+CSMP
8.2.4 AT+CPBW
2019.6.17 Modify these commands
8.2.5 AT+CNUM
5.2.14 AT+CGCLASS
14.2.1 AT+CHTPSERV
14.2.3 AT+CNTP
8.2.5 AT+CNUM
2019.7.8 Modify these commands
14.2.3 AT+CNTP
V1.01 2019.8.9 5.2.17 AT+CPING Add this command
2.2.8 ATI
2.2.14 ATX
2.2.18 AT+CGMM
2.2.19 AT+CGMR
4.2.2 AT+COPS
5.2.4 AT+CGACT
2019.8.9 5.2.5 AT+CGDCONT Modify these commands
5.2.7 AT+CGTFT
5.2.9 AT+CGEQREQ
5.2.11 AT+CGEQMIN
12.2.1 AT+FSCD
13.2.1 AT+CFTRANRX
13.2.2 AT+CFTRANTX
2019.12.11 4.2.2 AT+COPS Modify this command
2019.12.25 8.2.5 AT+CNUM Modify this command
2020.1.7 4.2.7 AT+CNMP Modify this command
2020.3.6 5.2.11 AT+CGEQMIN Modify this command

www.simcom.com 2 / 483
A76XX Series_AT Command Manual_V1.04

2020.3.11 4.2.7 AT+CNMP Modify this command


15 AT Commands for TCPIP
16 AT Commands for HTTP(S)
17 AT Commands for FTP(S)
Add Chapter
18 AT Commands for MQTT(S)
2020.3.23 15/16/17/18/19/21/22/23 and
19 AT Commands for SSL
reconstruct the chapters
20 AT Commands for TTS
21 AT Commands for AMR
22 AT Commands for SFOTA
Add Chapter 7 and reconstruct
2020.4.1 7 AT Commands for Call Control
the chapters
2020.4.10 8.2.5 AT+CNUM Modify this command
2020.4.20 5.2.7 AT+CGTFT Modify this command
2020.4.20 5.2.1 AT+CGREG Modify this command
4.2.2 AT+COPS
4.2.3 AT+CUSD
4.2.4 AT+CSSN
2020.4.20 4.2.7 AT+CNMP Modify these commands
4.2.10 AT+CNSMOD
4.2.11 AT+CTZU
4.2.12 AT+CTZR
18.2.3 AT+CMQTTACCQ
18.2.8 AT+CMQTTCONNECT
18.2.9 AT+CMQTTDISC
18.2.10 AT+CMQTTTOPIC
2020.4.26 Modify these commands
18.2.11 AT+CMQTTPAYLOAD
18.2.14 AT+CMQTTSUB
18.2.16 AT+CMQTTUNSUB
18.2.17 AT+CMQTTCFG
12.2.5 AT+FSDEL
12.2.6 AT+FSRENAME
2020.4.26 Modify these commands
12.2.8 AT+FSMEM
12.2.9 AT+FSCOPY
2020.4.26 10.2.10 AT+CFGRI Modify this command
2020.4.26 10.2.11 AT+CURCD Modify this command
2020.4.26 21.2.1 AT+CCMXPLAY Modify this command
2020.4.27 3.2.4 AT+CSQDELTA Modify this command
12 AT Commands for File System
2020.4.16 13AT Commands for File Add Notes to these chapters
Transmission
10.2.10 AT+CFGRI
17.2.2 AT+CFTPSSTOP
2020.4.29 17.2.9 AT+CFTPSPWD Modify these commands
17.2.14 AT+CFTPSPUT
17.2.15 AT+CFTPSSINGLEIP
www.simcom.com 3 / 483
A76XX Series_AT Command Manual_V1.04

17.2.17 AT+FTPSTYPE
21.2.1 AT+CCMXPLAY
2020.5.6 Modify these commands
21.2.2 AT+CCMXSTOP
12.2 Detailed Description of AT
2020.5.8 Add description to this section
Commands for File System
3.2.1 AT+CFUN
3.2.3 AT+AUTOCSQ
3.2 4 AT+CSQDELTA
3.3.10 AT+CCLK
3.3.11 AT+CMEE
4.2.7 AT+CNMP
4.2.9 AT+CPSI
5.2.2 AT+CEREG
5.2.3 AT+CGATT
2020.5.11 5.2.4 AT+CGACT Modify these commands
5.2.5 AT+CGDCONT
5.2.6 AT+CGDSCONT
5.2.8 AT+CGQREQ
5.2.9 AT+CGEQREQ
5.2.10 AT+CGQMIN
5.2.11 AT+CGEQMIN
5.2.15 AT+CGEREP
5.2.16 AT+CGAUTH
8.2.5 AT+CNUM
2.2.5 ATS0
2.2.21 AT+CSCS
6.2.4 AT+CPWD
2020.5.12 Modify these commands
6.2.7 AT+CRSM
19.2.2 AT+CCERTDOWN
19.2.12 AT+CCHOPEN
14.2.1 AT+CHTPSERV
14.2.2 AT+CHTPUPDATE
2020.5.13 Modify these commands
14.2.3 AT+CNTP
18.2.1 AT+CMQTTSTART
2.2.5 ATS0
9.2.1 AT+CSMS
9.2.2 AT+CPMS
9.2.3 AT+CMGF
9.2.5 AT+CSCB
2020.5.18 9.2.7 AT+CSDH Modify these commands
9.2.9 AT+CNMI
9.2.10 AT+CGSMS
9.2.11 AT+CMGL
9.2.12 AT+CMGR
9.2.13 AT+CMGS

www.simcom.com 4 / 483
A76XX Series_AT Command Manual_V1.04

9.2.14 AT+CMSS
9.2.15 AT+CMGW
9.2.16 AT+CMGD
9.2.18 AT+CMVP
9.2.19 AT+CMGRD
8.2.1 AT+CPBS
2020.5.19 8.2.2 AT+CPBR Modify these commands
8.2.4 AT+CPBW
6.2.11 AT+UIMHOTSWAPON
.2020.5.19 Add these commands
6.2.11 AT+UIMHOTSWAPLEVEL
2020.5.20 18 AT Commands for MQTT(S) Modify this chapter
3.2.11 AT+CMEE
4.2.4 AT+CSSN
4.2.6 AT+COPN
5.2.7 AT+CGTFT
2020.5.20 5.2.15 AT+CGEREP Modify these commands
5.2.16 AT+CGAUTH
5.2.17 AT+CGPIN
8.2.5 AT+CNUM
17.2.16 AT+CFTPSSIZE
15.2.1 AT+NETOPEN
15.2.3 AT+CIPOPEN
15.2.5 AT+CIPRXGET
2020.5.22 15.2.8 AT+CIPHEAD Modify these commands
15.2.9 AT+CIPSRIP
15.2.10 AT+CIPMODE
15.2.11 AT+CIPSENDMODE
2020.5.26 21.AT Commands for Audio Modify this chapter
2020.5.26 22.2.3 AT+CREC Add this command
2020.5.27 17.2.16 AT+CFTPSSIZE Modify this command
5.2.1 AT+CGREG
2020.5.28 Modify these commands
5.2.2 AT+CEREG
6.2.2 AT+CPIN
2020.5.29 6.2.3 AT+CLCK Modify these commands
6.2.4 AT+CPWD
12.2.9 AT+FSCOPY
2020.5.29 13.2.1 AT+CFTRANRX Modify these commands
13.2.2 AT+CFTRANTX
2020.5.29 18.2.9 AT+CMQTTDISC Modify this command
3.2.1 AT+CFUN
3.2.2 AT+CSQ
3.2.3 AT+AUTOCSQ
2020.6.1 Modify these commands
4.2.1 AT+CREG
4.2.3 AT+CUSD
4.2.5 AT+CPOL

www.simcom.com 5 / 483
A76XX Series_AT Command Manual_V1.04

4.2.11 AT+CTZU
4.2.12 AT+CTZR
9.2.1 AT+CSMS
9.2.5 AT+CSCB
9.2.7 AT+CSDH
9.2.8 AT+CNMA
2020.6.1 9.2.10 AT+CGSMS Modify these commands
9.2.11 AT+CMGL
9.2.13 AT+CMGS
9.2.16 AT+CMGD
9.2.18 AT+CMVP
2020.6.2 21.2.1 AT+CCMXPLAY Modify this command
11.2.1 AT+CVALARM
11.2.2 AT+CVAUXS
11.2.3 AT+CVAUXV
2020.6.3 11.2.6 AT+CMTE Modify these commands
11.2.7 AT+CPMVT
11.2.8 AT+CRIIC
11.2.10 AT+CBC
4.2.11 AT+CTZU
5.2.5 AT+CGDCONT
2020.6.3 Modify these commands
5.2.17 AT+CPING
8.2.2 AT+CPBR
16.2.8 AT+HTTPPOSTFILE
2020.6.3 Modify these commands
16.2.9 AT+HTTPREADFILE
12.2.3 AT+FSRMDIR
12.2.4 AT+FSLS
2020.6.4 12.2.8 AT+FSMEM Modify these commands
12.2.9 AT+FSCOPY
13.2.1 AT+CFTRANRX
5.2.13 AT+CGPADDR
15.2.3 AT+CIPOPEN
2020.6.10 Modify these commands
15.2.6 AT+CIPCLOSE
15.2.9 AT+CIPSRI
2020.6.19 All
2020.6.28 21.2.3 AT+CREC Modify this command
2020.6.28 17.2.14 AT+CFTPSPUT Modify this command
2020.6.28 23.3 Summary of CME ERROR codes Modify this section
2020.6.29 17.2.16 AT+CFTPSSIZE Modify this command
V1.02 2020.6.29 19.2.7 AT+CCHSTART Modify this command
2020.7.1 21.2.3 AT+CREC Modify this command
9.1Overview of AT Commands for
2020.7.2 Modify this section
SMS
2020.7.6 16.2.8 AT+HTTPPOSTFILE Modify this command

www.simcom.com 6 / 483
A76XX Series_AT Command Manual_V1.04

2020.7.10 23 AT Commands for GPS Add this chapter


10.2.2 AT&C
7.2.10 AT+CLIP
7.2.12 AT+COLP
2020.7.10 2.2.11 ATV Modify these commands
2.2.13 ATQ
2.2.14 ATX
2.2.21 AT+CSCS
21.2.1 AT+CCMXPLAY
2020.7.15 Modify these commands
21.2.3 AT+CREC
2020.7.21 16.2.8 AT+HTTPREAD Modify this command
12.2.1 AT+FSCD
12.2.2 AT+FSMKDIR
12.2.3 AT+FSRMDIR
13.2.1 AT+CFTRANRX
13.2.2 AT+CFTRANTX
3.2.10 AT+CCLK
5.2.2 AT+CEREG
5.2.4 AT+CGACT
4.2.6 AT+COPN"
4.2.4 AT+CSSN"
18.2.7 AT+CMQTTWILLMSG
5.2.16 AT+CGAUTH
3.2.2 AT+CSQ
3.2.3 AT+AUTOCSQ
3.2.5 AT+CPOF
3.2.6 AT+CRESET
3.2.7 AT+CACM
2020.8.11 Modify these commands
15.2.7 AT+IPADDR
15.2.10 AT+CIPMODE
3.2.12 AT+CPAS
15.2.2 AT+NETCLOSE
15.2.3 AT+CIPOPEN
15.2.4 AT+CIPSEND
15.2.6 AT+CIPCLOSE
15.2.15 AT+SERVERSTOP
15.2.16 AT+CIPACK
18.2.9 AT+CMQTTDISC
18.2.15 AT+CMQTTUNSUBTOPIC
4.2.2 AT+CGDCONT
3.2.8 AT+CAMM
3.2.9 AT+CPUC
5.2.4 AT+CGACT
4.2.2 AT+COPS
5.2.15 AT+CGEREP

www.simcom.com 7 / 483
A76XX Series_AT Command Manual_V1.04

10.2.3 AT+IPR
10.2.4 AT+IPREX
10.2.10 AT+CFGRI
23.2.8 AT+CGNSSNMEA
23.2.9 AT+CGPSNMEARATE
23.2.13 AT+CGNSSCMD
6.2.4 AT+CPWD
4.2.3 AT+CUSD
10.2.2 AT&C
3.2.12 AT+CPAS
7.2.20 AT+CMICGAIN
7.2.13 AT+VTS
7.2.14 AT+VTD
18.2.1 AT+CMQTTSTART
18.2.5 AT+CMQTTSSLCFG
13.2.1 AT+CFTRANRX
13.2.2 AT+CFTRANTX
23 AT Commands for GNSS
5.2.8 AT+CGQREQ
5.2.6 AT+CGDSCONT
20.2.1 AT+CTTS
20.2.2 AT+CTTSPARAM
7.2.20 AT+CMICGAIN
7.2.20 AT+COUTGAIN
19.2.1 AT+CSSLCFG
5.2.17 AT+CPING
15.2.17 AT+CDNSGIP
15.2.16 AT+CIPACK
15.2.6 AT+CIPCLOSE
23.2.1 AT+CGNSSPWR
23.2.2 AT+CGPSCOLD
23.2.4 AT+HOT
2020.8.11 Add these commands
4.2.9 AT+CPSI
5.2.7 AT+CGTFT
5.2.6 AT+CGDSCONT
2020.8.13 23.2.10 AT+CGPSFTM Modify this command
4.2.7 AT+CNMP
2020.8.14 Modify these commands
9.2.2 AT+CPMS
2020.8.18 23.2.5 AT+CCONFSAVE Delete this command
2020.8.18 15.2.4 AT+CIPSEND Add a note
2020.8.19 20.2.1 AT+CTTS Modify this command
24.1 Overview of AT Commands for
GNSS
2020.8.19 Modify these sections
24.2.5 AT+CGNSSIPR
24.2.7 AT+CGNSSNMEA

www.simcom.com 8 / 483
A76XX Series_AT Command Manual_V1.04

24.2.8 AT+CGPSNMEARATE
5.2.7 AT+CGTFT
2020.8.21 Modify these commands
5.2.5 AT+CGDCONT
2020.8.24 4.2.9 AT+CTTSPARAM Modify this command
2020.8.25 22 AT Commands for FOTA Add this chapter
2020.8.25 5.2.4 AT+CGACT Modify this command
7.2.5 AT+CRC
2020.8.25 Modify these commands
9.2.20 AT+CMGSEX
3.2.13 AT+SIMEI
2020.8.31 Modify these commands
16.6.26 AT+HTTPREAD
2020.9.1 25 AT Commands for WIFI Add this chapter
2020.9.1 19.2.11 AT+CCHCFG Modify this command
2020.9.2 16.2.7 AT+HTTPDATA Modify this command
17.4 Summary of Unsolicited Result
2020.9.2 Add this section
Codes
10.2.3 AT+IPR
2020.9.2 Delete these commands
10.2.4 AT+IPREX
2020.9.3 5.2.13 AT+CGPADDR Modify this command
2020.9.4 12.2.7 AT+FSATTRI Modify this command
4.2.4 AT+CSSN
2020.9.7 Modify these commands
4.2.8 AT+CNBP
2020.9.8 16.2.8 AT+HTTPPOSTFILE Modify this command
2020.9.11 22.2.2 AT+LFOTA Add this command
11.2.8 AT+CWIIC
2020.9.11 Modify these commands
11.2.8 AT+CRIIC

7.2.4 AT+CRLP
7.2.20 AT+CMICGAIN
7.2.21 AT+COUTGAIN
2.2.3 ATA
2020.9.14 Modify these commands
5.2.4 AT+CGACT
9.2.8 AT+CNMA
9.2.20 AT+CMGSEX
2.2.14 ATX
9.2.5 AT+CSCB
2020.9.15 Modify these commands
9.2.16 AT+CMGD
2020.9.16 22.2.2 AT+LFOTA Modify this command
2020.9.25 20.2.2 AT+CTTSPARAM Modify this command
16.2.3 AT+HTTPPARA
2020.9.25 Modify these commands
14.2.1 AT+HTPSERV
2020.9.29 24.2.13 AT+CGNSSPORTSWITCH Add this command
16.2.6 AT+HTTPREAD
2020.10.10 Modify these commands
16.2.8 AT+HTTPPOSTFILE
2020.10.15 18.2.15 AT+CMQTTUNSUBTOPIC Modify this command
www.simcom.com 9 / 483
A76XX Series_AT Command Manual_V1.04

16.2.6 AT+HTTPREAD
2020.10.20 Modify these command
18.2.17 AT+CMQTTCFG
2020.10.21 25.2.2 AT+CWSTASCANEX Add this command
2020.10.29 12.2.9 AT+FSCOPY Modify this command
2020.10.30 2.2.1 A/ Delete this command
2020.11.2 11.2.15 Unsolicited result codes Modify this section
16.2.3 AT+HTTPPARA
5.2.17 AT+CPING
16.2.8 AT+HTTPPOSTFILE
4.2.2 AT+COPS
4.2.8 AT+CNBP
7.2.8 AT+CCWA
7.2.2 AT+CHUP
7.2.11 AT+CLIR
2020.11.2 22.2.2 AT+LFOTA Modify these commands
11.2.7 AT+CPMVT
5.2.14 AT+CGCLASS
15.2.4 AT+CIPSEND
15.2.5 AT+CIPRXGET
15.2.6 AT+CIPCLOSE
15.2.16 AT+CIPACK
15.2.17 AT+CDNSGIP
23.2.2 AT+CSCFOTA
18.2.9 AT+CMQTTDISC
19.2.13 AT+CCHCLOSE
10.2.6 AT+IFC
24.2.5 AT+CGNSSIPR
24.2.6 AT+CGNSSMODE
24.2.10 AT+CGPSINFO
2020.11.3 25.2.1 AT+CWSTASCAN Modify these commands
25.2.2 AT+CWSTASCANEX
16.2.3 AT+HTTPPARA
20.2.1 AT+CTTS
22.2.1 AT+CFOTA
19.2.2 AT+CCERTDOWN
24.2.13 AT+CGNSSPORTSWITCH
17.2.3 AT+CFTPSLOGIN
17.2.12 AT+CFTPSPUTFILE
17.2.17 AT+CFTPSTYPE
17.2.18 AT+CFTPSSLCFG
2020.11.7 21.2.3 AT+CREC Modify these commands
20.2.1 AT+CTTS
20.2.2 AT+CTTSPARAM
21.1 AT Commands for Audio
15.2.4 AT+CIPSEND

www.simcom.com 10 / 483
A76XX Series_AT Command Manual_V1.04

24.2.1 AT+CGNSSPWR
7.2.12 AT+COLP
7.2.11 AT+CLIR
3.3.7 AT+CACM
3.3.8 AT+CAMM
4.2.9 AT+CPSI
5.2.14 AT+CGCLASS
15.2.15 AT+SERVERSTOP
24.2.13 AT+CGNSSPORTSWITCH
15.2.18 AT+CSOCKSETPN
2020.11.13 Add these commands
24.2.14 AT+CAGPS
15.2.5 AT+CIPRXGET
15.2.3 AT+CIPOPEN
8.2.1 AT+CPBS
7.2.11 AT+VTS
7.2.12 AT+COLP
7.2.11 AT+CLIP
10.2.5 AT+ICF
2020.11.13 9.2.20 AT+CMGSEX Modify these commands
6.2.3 AT+CLCK
6.2.4 AT+CPWD
23.2.1 AT+CAPFOTA
17.2.2 AT+CFTPSSTOP
9.2.9 AT+CNMI
9.2.12 AT+CMGR
6.2.7 AT+CRSM
24.2.13 AT+CGNSSPORTSWITCH
17.2.12 AT+CFTPSPUTFILE
17.2.18 AT+CFTPSSLCFG
20.2.2 AT+CTTSPARAM
2020.11.15 Modify these commands
4.2.9 AT+CPSI
15.2.18 AT+CSOCKSETPN
15.2.5 AT+CIPRXGET
9.2.12 AT+CMGR
3.2.10 AT+CCLK
9.2.8 AT+CNMA
16.2.4 AT+HTTPACTION
16.2.9 AT+HTTPREADFILE
15.2.14 AT+SERVERSTART
2020.11.16 5.2.1 AT+CGREG Modify these commands
4.2.7 AT+CNMP
2.2.1 ATD
16.2.8 AT+HTTPPOSTFILE
3.2.4 AT+CSQDELTA
3.2.10 AT+CCLK

www.simcom.com 11 / 483
A76XX Series_AT Command Manual_V1.04

24.2.7 AT+CGNSSNMEA
2020.11.25 Modify these commands
10.2.6 AT+IFC
7.2.13 AT+VTS
2020.11.30 7.2.3 AT+CBST Modify these commands
6.2.3 AT+CLCK
7.2.3 AT+CRLP
2020.12.1 2.2.2 ATA Modify these commands
4.2.3 AT+CUSD
2020.12.3 6.2.3 AT+CLCK Modify this command
2020.12.4 16.2.5 AT+HTTPHEAD Modify this command
2020.12.7 10.2.10 AT+CFGRI Modify this command
2020.12.14 24.2.13 AT+CGNSSPORTSWITCH Modify this command

4.2.3 AT+CUSD
2020.12.21 7.2.3 AT+CBST Modify these commands
10.2.11 AT+CURCD
2020.12.22 20.2.2 AT+CTTSPARAM Modify this command
1.4 Definitions and Conventions
2020.12.28 26.2 Response String of AT+CEER Modify these sections
26.3 Summary of CME ERROR Codes
V1.03 9.2.1 AT+CSMS
9.2.2 AT+CPMS
2020.12.28 Modify these commands
7.2.13 AT+VTS
4.2.11 AT+CTZU
2020.12.31 20.2.3 AT+CDTAM Add this command
2020.12.31 21.2.1 AT+CCMXPLAY Modify this command
4.2.1 AT+CREG
4.2.4 AT+CSSN
2021.1.7 Modify these commands
4.2.9 AT+CPSI
5.2.15 AT+CGEREP
2021.1.8 18.2.8 AT+CMQTTCONNECT Modify this command
2021.1.12 7.2.9 AT+CCFC Modify this command
11.2.5 AT+CADC2
2021.1.14 Modify these commands
7.2.21 AT+COUTGAIN
9.2.20 AT+CMGSEX
15.2.18 AT+CSOCKSETPN
2021.1.15 Modify these commands
15.2.6 AT+CIPCLOSE
5.2.8 AT+CGQREQ
11.2.7 AT+CPMVT
8.2.4 AT+CPBW
2021.1.29 9.2.5 AT+CSCB Modify these commands
9.2.21 AT+CMSSEX
9.2.6 AT+CSMP

www.simcom.com 12 / 483
A76XX Series_AT Command Manual_V1.04

21.2.3 AT+CREC
All Add support on A7678 Series
3.2.10 AT+CCLK
Modify these commands
2021.2.3 7.2.12 AT+COLP
modify this chapter for A7678
24 AT Commands for GNSS
Series
2021.3.12 18.2.15 AT+CMQTTUNSUBTOPIC Modify this command
12.2Detailed Description of AT
2021/2/4 Modify this command
Commands for File System
2021/3/5 14.2.1 AT+CHTPSERV Modify this command
11.2.7AT+CPMVT Low and high
voltage Power Off
4.2.2 AT+COPS Operator selection
15.2.6AT+CIPCLOSE Close TCP or
2021/3/16 UDP Socket Modify this command
9.2.15AT+CMGW Write message to
memory
14.2.3AT+CNTP rectify parameter
range
13.2.3AT+CFTRXBUF
13.1 AT+CFTRANRX
2021/3/10 Add this command
13.1 AT+CFTRANTX
13.1 AT+CFTRXBUF

4.2.4 AT+CSSN
25.2.1 AT+CWSTASCAN
2021/3/26 Modify this command
25.2.2 AT+CWSTASCANEX
2.2.9 AT&V

2021/3/29 14.2.3 AT+CCLK Modify this command


5.2.2AT+CEREG EPS network
2021/3/30 Modify this command
registration status
9.2.18AT+CMVP Set message valid
2021/3/30 Modify this command
period
9.2.10 AT+CGSMS Select service for
2021/3/30 Modify this command
MO SMS messages
2021/3/30 10.2.7 AT+CSCLK Modify this command
2021/3/30 15.2.8 AT+CSOCKSETPN Modify this command
2021/3/30 22.2.1AT+CFOTA Modify this command
2021/3/31 9.2.16 AT+CMGD Modify this command
2021/3/31 16.2.8 AT+HTTPPOSTFILE Modify this command
2021/4/1 26 Added Ble At Add this chapter
2021/4/14 25.2.2 AT+CWSTASCANEX Modify this command

www.simcom.com 13 / 483
A76XX Series_AT Command Manual_V1.04

2021/4/22 7.2.3 AT+CBST Modify this command


26.2.19 +BLESRREQ
2021/4/22 26.2.20 +BLESWREQ Add this command
26.2.21 +BLESCON
26.2.9 AT+BLESLSTART
2021/4/22 Modify this command
26.2.11 AT+BLEADV
2021/4/27 20.2.3 AT+CDTAM Modify this command
16.2.1 AT+HTTPINIT
16.2.2 AT+HTTPTERM
16.2.3 AT+HTTPPARA
16.2.5 AT+HTTPHEAD
16.2.6 AT+HTTPREAD
2021/4/27 Add there Test commands
16.2.7 AT+HTTPDATA
17.2.1 AT+CFTPSSTART
17.2.2 AT+CFTPSSTOP
17.2.5 AT+CFTPSLIST
17.2.9 AT+CFTPSPWD
26.2.1 AT+BLESREG
2021/4/28 Modify this command
26.2.21 +BLESCONN
16.2.3 AT+HTTPPARA
2021/4/28 Modify this command
16.2.8 AT+HTTPPOSTFILE

2021/4/29 20.2.1 AT+CTTS Modify this command

2021/4/30 9.2.21 AT+CMSSEX Modify this command

2.2.4ATS0 Automatic answer incoming


call
2021/4/30 Modify the word
22.3 Unsolicited Result Codes
16.2.5 AT+HTTPHEAD

2021/5/7 23.2.2 AT+CSCFOTA Modify the word

2021/5/8 11.2.7 AT+CPMVT Modify the word

2021/5/10 21.2.2 AT+CCMXSTOP Modify this command

17.2.14 AT+CFTPSPUT
26.2.1 AT+BLEPOWER
2021/5/10 Modify this command
26.2.10 AT+BLESSCRM
26.2.12 AT+BLESSDRM
26.2.1 AT+BLEPOWER
2021/5/13 26.2.5 AT+BLESREG Modify this command
26.2.7 AT+BLESSAD

www.simcom.com 14 / 483
A76XX Series_AT Command Manual_V1.04

26.2.9 AT+BLESSCAD
26.2.11 AT+BLESSDAD

7.2.11 AT+CLIR
2021/5/14 Modify these commands
7.2.12 AT+COLP

2021/5/17 14.2.1 AT+CHTPSERV Modify the word

9.2.15 AT+CMGW
2021/5/18 Modify these commands
9.2.20 AT+CMGSEX
26.2.2 AT+BLESTATUS
26.2.3 AT+BLEHOST
26.2.4 AT+BLEADDRESS
26.2.5 AT+BLESREG
26.2.6 AT+BLESDREG
2021/5/19 Modify these commands
10.2.10AT+CFGRI
24.2.6AT+CGNSSIPR
24.2.9AT+CGPSNMEARATE
24.2.7 AT+CGNSSMODE
21.2.3 AT+CREC

2021/5/31 21.2.3 AT+CREC Modify this commands

12.1Overview of AT Commands for Modify the length of actual fully


2021/6/1
File System qualified names

2021/6/1 12.2.6 AT+FSRENAME Delete the Note

5.2.4 AT+CGACT
2021/6/2 Modify these commands
7.2.12 AT+COLP
6.2.12 AT+SWITCHSIM
2021/6/16 6.2.13 AT+DUALSIM Add these commands
6.2.14 AT+BINDSIM

2021/6/17 21.2.3 AT+CREC Modify this commands

2021/6/29 22.2.1AT+CFOTA Modify URC report

2.2.1 ATD
2.2.2 ATA
2.2.3 ATH
2021/6/29 7.2.2 AT+CHUP Modify these commands
7.2.11 AT+CLIR
7.2.12 AT+COLP
7.2.15 AT+CSTA

www.simcom.com 15 / 483
A76XX Series_AT Command Manual_V1.04

2021/6/29 21.2.3 AT+CREC Modify comment

4.2.1 AT+CREG
2021/6/30 5.2.1 AT+CGREG Add state
5.2.2 AT+CEREG
14.2.1 AT+CHTPSERV
2021/6/30 17.2Overview of AT Commands for Modify parameter
FTP.

2021/6/30 20.2.1 AT+CTTS Modify comment

2021/7/7 21.2.3 AT+CREC Modify comment

2021/7/8 24.2.6 AT+CGNSSIPR Add notes

15.2.18 AT+CSOCKSETPN Modify comment


2021/7/13
21.2.3 AT+CREC
6.2.12 AT+SWITCHSIM
2021/7/13 6.2.13 AT+DUALSIM Modify these commands
6.2.14 AT+BINDSIM
7.2.7 AT+CEER
7.2.13 AT+VTS
2021/7/19 Modify these commands
7.2.15 AT+CSTA
7.2.16 AT+CMOD
16.2.5AT+HTTPHEAD
16.2.6AT+HTTPREAD
2021/7/23 Modify these commands
16.2.7AT+HTTPDATA
16.2.8AT+HTTPPOSTFILE
V1.04 17.2.5 AT+CFTPSLIST
2021/7/23 Modify comment
17.2.16 AT+CFTPSSIZE
15.2.2 AT+NETCLOSE
15.2.18 AT+CSOCKSETPN
24.2.3 AT+CGPSCOLD
2021/7/28 24.2.4 AT+CGPSWARM Modify these commands
24.2.5 AT+CGPSHOT
25.2.1 AT+CWSTASCAN
25.2.2 AT+CWSTASCANEX

2021/7/28 24.2.16 AT+CGNSSPROD Add this command

14.2.1 AT+CHTPSERV
2021/7/29 11.2.1 AT+CVALARM Modify these comment
11.2.7 AT+CPMVT

2021/7/30 4.2.11 AT+CTZU Modify comment

www.simcom.com 16 / 483
A76XX Series_AT Command Manual_V1.04

24.2.2 AT+CGNSSTST
2021/7/30 Modify these commands
10.2.11 AT+CURCD

www.simcom.com 17 / 483
A76XX Series_AT Command Manual_V1.04

Contents

Version History..................................................................................................................................... 2
Contents............................................................................................................................................... 18
Introduction......................................................................................................................................28
Scope of the document................................................................................................................................. 28
Related documents........................................................................................................................................ 28
Terms and Abbreviations...............................................................................................................................29
Definitions and Conventions.........................................................................................................................30
AT Interface Synopsis.................................................................................................................................... 31
Interface Settings..........................................................................................................................31
AT Commands Syntax................................................................................................................. 31
Supported character sets............................................................................................................ 33

AT Commands According to V.25TER.......................................................................................34


Overview of AT Commands According to V.25TER..................................................................................34
Detailed Description of AT Commands for V.25TER................................................................................34
ATD Mobile originated call to dial a number..........................................................................35
ATA Call answer......................................................................................................................... 36
ATH Disconnect existing call....................................................................................................37
ATS0 Automatic answer incoming call................................................................................... 38
+++ Switch from data mode to command mode.................................................................. 39
ATO Switch from command mode to data mode..................................................................39
ATI Display product identification information.......................................................................40
ATE Enable command echo.................................................................................................... 41
AT&V Display current configuration........................................................................................42
ATV Set result code format mode........................................................................................... 43
AT&F Set all current parameters to manufacturer defaults................................................ 44
ATQ Set Result Code Presentation Mode.............................................................................44
ATX Set CONNECT Result Code Format............................................................................. 45
AT&W Save the user setting to ME........................................................................................ 46
ATZ Restore the user setting from ME...................................................................................47
AT+CGMI Request manufacturer identification.................................................................... 48
AT+CGMM Request model identification...............................................................................49
AT+CGMR Request revision identification............................................................................ 49
AT+CGSN Request product serial number identification....................................................50
AT+CSCS Select TE character set......................................................................................... 51
AT+GCAP Request overall capabilities..................................................................................52

AT Commands for Status Control.............................................................................................. 54

www.simcom.com 18 / 483
A76XX Series_AT Command Manual_V1.04

Overview of AT Commands for Status Control..........................................................................................54


Detailed Description of AT Commands for Status Control...................................................................... 54
AT+CFUN Set phone functionality.......................................................................................... 54
AT+CSQ Query signal quality..................................................................................................56
AT+AUTOCSQ Set CSQ report...............................................................................................57
AT+CSQDELTA Set RSSI delta change threshold...............................................................58
AT+CPOF Power down the module........................................................................................59
AT+CRESET Reset the module.............................................................................................. 60
AT+CACM Accumulated call meter........................................................................................ 60
AT+CAMM Accumulated call meter maximum..................................................................... 62
AT+CPUC Price per unit and currency table........................................................................ 63
AT+CCLK Real time clock management............................................................................... 64
AT+CMEE Report mobile equipment error............................................................................66
AT+CPAS Phone activity status.............................................................................................. 67
AT+SIMEI Set the IMEI for the module.................................................................................. 68

AT Commands for Network..........................................................................................................70


Overview of AT Commands for Network.................................................................................................... 70
Detailed Description of AT Commands for Network................................................................................. 70
AT+CREG Network registration.............................................................................................. 70
AT+COPS Operator selection..................................................................................................72
AT+CUSD Unstructured supplementary service data......................................................... 74
AT+CSSN Supplementary service notifications................................................................... 76
AT+CPOL Preferred operator list............................................................................................ 78
AT+COPN Read operator names........................................................................................... 80
AT+CNMP Preferred mode selection..................................................................................... 81
AT+CNBP Preferred band selection....................................................................................... 82
AT+CPSI Inquiring UE system information........................................................................... 84
AT+CNSMOD Show network system mode..........................................................................86
AT+CTZU Automatic time and time zone update.................................................................88
AT+CTZR Time and time zone reporting............................................................................... 89

AT Commands for Packet Domain.............................................................................................92


Overview of AT Commands for Packet Domain........................................................................................92
Detailed Description of AT Commands for Packet Domain.................................................................... 92
AT+CGREG Network registration status............................................................................... 92
AT+CEREG EPS network registration status....................................................................... 94
AT+CGATT Packet domain attach or detach........................................................................ 96
AT+CGACT PDP context activate or deactivate.................................................................. 97
AT+CGDCONT Define PDP context.......................................................................................99
AT+CGDSCONT Define Secondary PDP Context............................................................ 102
AT+CGTFT Traffic Flow Template........................................................................................ 103
AT+CGQREQ Quality of service profile (requested)......................................................... 107
AT+CGEQREQ 3G quality of service profile (requested)................................................. 110
AT+CGQMIN Quality of service profile (minimum acceptable)........................................115
AT+CGEQMIN 3G quality of service profile (minimum acceptable)............................... 117
AT+CGDATA Enter data state............................................................................................... 122
www.simcom.com 19 / 483
A76XX Series_AT Command Manual_V1.04

AT+CGPADDR Show PDP address..................................................................................... 123


AT+CGCLASS GPRS mobile station class.........................................................................125
AT+CGEREP GPRS event reporting................................................................................... 127
AT+CGAUTH Set type of authentication for PDP-IP connections of GPRS................. 134
AT+CPING Ping destination address.................................................................................136

AT Commands for SIM Card...................................................................................................... 138


Overview of AT Commands for SIM Card................................................................................................138
Detailed Description of AT Commands for SIM Card............................................................................ 138
AT+CICCID Read ICCID from SIM card..............................................................................138
AT+CPIN Enter PIN.................................................................................................................139
AT+CLCK Facility lock............................................................................................................ 141
AT+CPWD Change password...............................................................................................142
AT+CIMI Request international mobile subscriber identity.............................................. 144
AT+CSIM Generic SIM access..............................................................................................145
AT+CRSM Restricted SIM access........................................................................................146
AT+SPIC Times remain to input SIM PIN/PUK.................................................................. 151
AT+CSPN Get service provider name from SIM................................................................151
AT+UIMHOTSWAPON Set UIM Hotswap Function On....................................................152
AT+UIMHOTSWAPLEVEL Set UIM Card Detection Level.............................................. 154
AT+SWITCHSIM Switch master SIM................................................................................... 155
AT+DUALSIM Set dual-sim mode........................................................................................ 156
AT+BINDSIM Bind ATP to SIM1 or SIM2............................................................................ 157

AT Commands for Call Control.................................................................................................159


Overview of AT Commands for Call Control............................................................................................159
Detailed Description of AT Commands for Call Control........................................................................ 159
AT+CVHU Voice hang up control..........................................................................................159
AT+CHUP Hang up call.......................................................................................................... 161
AT+CBST Select bearer service type.................................................................................. 162
AT+CRLP Radio link protocol................................................................................................164
AT+CRC Cellular result codes.............................................................................................. 166
AT+CLCC List current calls....................................................................................................167
AT+CEER Extended error report.......................................................................................... 169
AT+CCWA Call waiting........................................................................................................... 170
AT+CCFC Call forwarding number and conditions............................................................172
AT+CLIP Calling line identification presentation................................................................ 174
AT+CLIR Calling line identification restriction.....................................................................176
AT+COLP Connected line identification presentation....................................................... 178
AT+VTS DTMF and tone generation....................................................................................179
AT+VTD Tone duration........................................................................................................... 180
AT+CSTA Select type of address..........................................................................................182
AT+CMOD Call mode............................................................................................................. 183
AT+VMUTE Speaker mute control....................................................................................... 184
AT+CMUT Microphone mute control....................................................................................185
AT+CSDVC Switch voice channel device........................................................................... 186
AT+CMICGAIN Adjust mic gain............................................................................................ 187
www.simcom.com 20 / 483
A76XX Series_AT Command Manual_V1.04

AT+COUTGAIN Adjust out gain............................................................................................ 188

AT Commands for Phonebook..................................................................................................190


Overview of AT Commands for Phonebook............................................................................................ 190
Detailed Description of AT Commands for Phonebook......................................................................... 190
AT+CPBS Select phonebook memory storage.................................................................. 190
AT+CPBR Read phonebook entries.....................................................................................192
AT+CPBF Find phonebook entries.......................................................................................193
AT+CPBW Write phonebook entry....................................................................................... 195
AT+CNUM Subscriber number..............................................................................................196

AT Commands for SMS...............................................................................................................198


Overview of AT Commands for SMS........................................................................................................ 198
Detailed Description of AT Commands for SMS.....................................................................................199
AT+CSMS Select message service......................................................................................199
AT+CPMS Preferred message storage............................................................................... 200
AT+CMGF Select SMS message format.............................................................................202
AT+CSCA SMS service centre address.............................................................................. 203
AT+CSCB Select cell broadcast message indication........................................................204
AT+CSMP Set text mode parameters..................................................................................206
AT+CSDH Show text mode parameters..............................................................................207
AT+CNMA New message acknowledgement to ME/TA................................................... 208
AT+CNMI New message indications to TE......................................................................... 210
AT+CGSMS Select service for MO SMS messages......................................................... 212
AT+CMGL List SMS messages from preferred store........................................................213
AT+CMGR Read message.................................................................................................... 217
AT+CMGS Send message.....................................................................................................222
AT+CMSS Send message from storage............................................................................. 223
AT+CMGW Write message to memory................................................................................224
AT+CMGD Delete message.................................................................................................. 226
AT+CMGMT Change message status................................................................................. 227
AT+CMVP Set message valid period...................................................................................228
AT+CMGRD Read and delete message............................................................................. 229
AT+CMGSEX Send message............................................................................................... 231
AT+CMSSEX Send multi messages from storage............................................................ 232

AT Commands for Serial Interface........................................................................................ 235


Overview of AT Commands for Serial Interface................................................................................... 235
Detailed Description of AT Commands for Serial Interface................................................................ 235
AT&D Set DTR function mode...............................................................................................235
AT&C Set DCD function mode.............................................................................................. 236
AT+IPR Set local baud rate temporarily.............................................................................. 237
AT+IPREX Set local baud rate permanently.......................................................................238
AT+ICF Set control character framing................................................................................. 239
AT+IFC Set local data flow control....................................................................................... 240
AT+CSCLK Control UART Sleep.......................................................................................... 241
AT+CMUX Enable the multiplexer over the UART............................................................ 243

www.simcom.com 21 / 483
A76XX Series_AT Command Manual_V1.04

AT+CATR Configure URC destination interface................................................................ 244


AT+CFGRI Configure RI pin.......................................................................................... 245
AT+CURCD Configure the delay time and number of URC.................................... 246

AT Commands for Hardware................................................................................................... 248


Overview of AT Commands for Hardware............................................................................................. 248
Detailed Description of AT Commands for Hardware.......................................................................... 248
AT+CVALARM Low and high voltage Alarm....................................................................... 248
AT+CVAUXS Set state of the pin named VDD_AUX........................................................ 249
AT+CVAUXV Set voltage value of the pin named VDD_AUX......................................... 250
AT+CADC Read ADC value...................................................................................................251
AT+CADC2 Read ADC2 value.............................................................................................. 252
AT+CMTE Control the module critical temperature URC alarm......................................253
AT+CPMVT Low and high voltage Power Off.....................................................................254
AT+CRIIC Read values from register of IIC device nau8810.......................................... 256
AT+CWIIC Write values to register of IIC device nau8810.............................................. 257
AT+CBC Read the voltage value of the power supply..............................................257
AT+CPMUTEMP Read the temperature of the module............................................258
AT+CGDRT Set the direction of specified GPIO........................................................259
AT+CGSETV Set the value of specified GPIO...........................................................260
AT+CGGETV Get the value of specified GPIO..........................................................261
Unsolicited Result Codes..........................................................................................................................262

AT Commands for File System...............................................................................................263


Overview of AT Commands for File System..........................................................................................263
Detailed Description of AT Commands for File System...................................................................... 263
AT+FSCD Select directory as current directory................................................................. 264
AT+FSMKDIR Make new directory in current directory.................................................... 265
AT+FSRMDIR Delete directory in current directory...........................................................266
AT+FSLS List directories/files in current directory.............................................................267
AT+FSDEL Delete file in current directory.......................................................................... 268
AT+FSRENAME Rename file in current directory............................................................. 269
AT+FSATTRI Request file attributes.................................................................................... 270
AT+FSMEM Check the size of available memory..............................................................271
AT+FSCOPY Copy an appointed file................................................................................... 272

AT Commandsfor FileTransmission...............................................................................................275
Overview of AT Commands for File Transmission............................................................................... 275
Detailed Description of AT Commands for File Transmission............................................................275
AT+CFTRANRX Transfer a file to EFS................................................................................275
AT+CFTRANTX Transfer a file from EFS to host.............................................................. 276
AT+CFTRXBUF Sets the size of the buffer to transfer files to EFS............................... 278

AT Commands for Internet Service....................................................................................... 280


Overview of AT Commands for Internet Service.................................................................................. 280
Detailed Description of AT Commands for Internet Service............................................................... 280
AT+CHTPSERV Set HTP server information..................................................................... 280
AT+CHTPUPDATE Updating date time using HTP protocol........................................... 281
www.simcom.com 22 / 483
A76XX Series_AT Command Manual_V1.04

AT+CNTP Update system time............................................................................................. 282


Command Result Codes.......................................................................................................................... 283
Description of <err> of HTP...................................................................................................... 283
Description of <err> of NTP...................................................................................................... 284

AT Commands for TCP/IP........................................................................................................ 285


Overview of AT Commands for TCP/IP..................................................................................................285
Detailed Description of AT Commands for TCP/IP.............................................................................. 285
AT+NETOPEN Start Socket Service....................................................................................285
AT+NETCLOSE Stop Socket Service..................................................................................287
AT+CIPOPEN Establish Connection in Multi-Socket Mode.............................................288
AT+CIPSEND Send data through TCP or UDP Connection............................................291
AT+CIPRXGET Set the Mode to Retrieve Data.................................................................294
AT+CIPCLOSE Close TCP or UDP Socket........................................................................ 296
AT+IPADDR Inquire Socket PDP address.......................................................................... 298
AT+CIPHEAD Add an IP Header When Receiving Data..................................................299
AT+CIPSRIP Show Remote IP Address and Port............................................................. 300
AT+CIPMODE Set TCP/IP Application Mode............................................................. 302
AT+CIPSENDMODE Set Sending Mode.................................................................... 303
AT+CIPTIMEOUT Set TCP/IP Timeout Value............................................................ 304
AT+CIPCCFG Configure Parameters of Socket........................................................ 305
AT+SERVERSTART Startup TCP Sever.....................................................................307
AT+SERVERSTOP Stop TCP Sever........................................................................... 308
AT+CIPACK Query TCP Connection Data Transmitting Status.............................. 309
AT+CDNSGIP Query the IP Address of Given Domain Name................................ 310
AT+CSOCKSETPN Set active PDP context's profile................................................ 311
Command Result Codes.......................................................................................................................... 313
Description of <err_info>...........................................................................................................313
Description of <err>....................................................................................................................314
Unsolicited Result Codes......................................................................................................................... 314

AT Commands for HTTP(S)..................................................................................................... 316


Overview of AT Commands for HTTP(S)...............................................................................................316
Detailed Description of AT Commands for HTTP(S)........................................................................... 316
AT+HTTPINIT Start HTTP Service....................................................................................... 316
AT+HTTPTERM Stop HTTP Service................................................................................... 317
AT+HTTPPARA Set HTTP Parameters value.................................................................... 318
AT+HTTPACTION HTTP Method Action............................................................................. 320
AT+HTTPHEAD Read the HTTP Header Information of Server Response..................321
AT+HTTPREAD Read the response information of HTTP Server..................................322
AT+HTTPDATA Input HTTP Data......................................................................................... 324
AT+HTTPPOSTFILE Send HTTP Request to HTTP(S)server by File...........................325
AT+HTTPREADFILE Receive HTTP Response Content to a file...................................326
Command Result Codes.......................................................................................................................... 328
Description of <statuscode>..................................................................................................... 328
Description of <errcode>...........................................................................................................329
Unsolicited Result Codes......................................................................................................................... 330
www.simcom.com 23 / 483
A76XX Series_AT Command Manual_V1.04

AT Commands for FTP(S)........................................................................................................ 331


Overview of AT Commands for FTP(S)..................................................................................................331
Detailed Description of AT Commands for FTP(S).............................................................................. 331
AT+CFTPSSTART Start FTP(S)service.............................................................................. 331
AT+CFTPSSTOP Stop FTP(S)Service................................................................................332
AT+CFTPSLOGIN Login to a FTP(S)server.......................................................................333
AT+CFTPSLOGOUT Logout a FTP(S)server.....................................................................335
AT+CFTPSLIST List the items in the directory on FTP(S)server....................................336
AT+CFTPSMKD Create a new directory on FTP(S)server.............................................. 337
AT+CFTPSRMD Delete a directory on FTP(S)server.......................................................338
AT+CFTPSCWD Change the current directory on FTP(S)server...................................339
AT+CFTPSPWD Get the current directory on FTP(S)server...........................................340
AT+CFTPSDELE Delete a file on FTP(S)server........................................................341
AT+CFTPSGETFILE Download a file from FTP(S)server to module.....................342
AT+CFTPSPUTFILE Upload a file from module to FTP(S)server.......................... 343
AT+CFTPSGET Get a file from FTP(S)server to serial port.................................... 344
AT+CFTPSPUT Put a file to FTP(S)server through serial port............................... 346
AT+CFTPSSINGLEIP Set FTP(S)data socket address type...................................347
AT+CFTPSSIZE Get the file size on FTP(S)server...................................................348
AT+CFTPSTYPE Set the transfer type on FTP(S)server.........................................349
AT+CFTPSSLCFG Set the SSL context id for FTPS session................................. 350
Command Result Codes.......................................................................................................................... 351
Description of <errcode>...........................................................................................................351
Unsolicited Result codes.......................................................................................................................... 352

AT Commands for MQTT(S).................................................................................................... 353


Overview of AT Commands for MQTT(S)..............................................................................................353
Detailed Description of AT Commands for MQTT(S).......................................................................... 353
AT+CMQTTSTART Start MQTT service..............................................................................353
AT+CMQTTSTOP Stop MQTT service................................................................................354
AT+CMQTTACCQ Acquire a client.......................................................................................355
AT+CMQTTREL Release a client......................................................................................... 357
AT+CMQTTSSLCFG Set the SSL context (only for SSL/TLS MQTT)...........................358
AT+CMQTTWILLTOPIC Input the topic of will message.................................................. 359
AT+CMQTTWILLMSG Input the will message...................................................................360
AT+CMQTTCONNECT Connect to MQTT server............................................................. 361
AT+CMQTTDISC Disconnect from server.......................................................................... 363
AT+CMQTTTOPIC Input the topic of publish message............................................365
AT+CMQTTPAYLOAD Input the publish message....................................................366
AT+CMQTTPUB Publish a message to server.......................................................... 367
AT+CMQTTSUBTOPIC Input the topic of subscribe message............................... 368
AT+CMQTTSUB Subscribe a message to server..................................................... 370
AT+CMQTTUNSUBTOPIC Input the topic of unsubscribe message.....................372
AT+CMQTTUNSUB Unsubscribe a message to server........................................... 373
AT+CMQTTCFG Configure the MQTT Context......................................................... 375
Command Result Codes.......................................................................................................................... 376

www.simcom.com 24 / 483
A76XX Series_AT Command Manual_V1.04

Description of <err>....................................................................................................................376
Unsolicited Result Codes......................................................................................................................... 377

AT Commands for SSL............................................................................................................. 380


Overview of AT Commands for SSL....................................................................................................... 380
Detailed Description of AT Commands for SSL....................................................................................380
AT+CSSLCFG Configure the SSL Context.........................................................................380
AT+CCERTDOWN Download certificate into the module................................................ 385
AT+CCERTLIST List certificates...........................................................................................386
AT+CCERTDELE Delete certificates................................................................................... 387
AT+CCHSET Configure the report mode of sending and receiving data...................... 388
AT+CCHMODE Configure the mode of sending and receiving data..............................389
AT+CCHSTART Start SSL service....................................................................................... 390
AT+CCHSTOP Stop SSL service......................................................................................... 391
AT+CCHADDR Get the IPv4 address..................................................................................392
AT+CCHSSLCFG Set the SSL context....................................................................... 392
AT+CCHCFG Configure the Client Context................................................................394
AT+CCHOPEN Connect to server................................................................................395
AT+CCHCLOSE Disconnect from server....................................................................397
AT+CCHSEND Send data to server.............................................................................398
AT+CCHRECV Read the cached data that received from the server....................399
Command Result Codes.......................................................................................................................... 402
Description of <err>....................................................................................................................402
Unsolicited Result Codes......................................................................................................................... 403

AT Commands for TTS..............................................................................................................404


Overview of AT Commands for TTS....................................................................................................... 404
Detailed Description of AT Commands for TTS....................................................................................404
AT+CTTS TTS operation........................................................................................................404
AT+CTTSPARAM Set TTS Parameters.............................................................................. 406
AT+CDTAM Set Local or Remote Audio Play.....................................................................407

AT Commands for Audio.......................................................................................................... 409


Overview of AT Commands for Audio.................................................................................................... 409
Detailed Description of AT Commands for Audio................................................................................. 409
AT+CCMXPLAY Play audio file.............................................................................................409
AT+CCMXSTOP Stop playing audio file..............................................................................411
AT+CREC Record audio File................................................................................................. 411

AT Commands for FOTA...........................................................................................................415


Overview of AT Command for FOTA...................................................................................................... 415
Detailed Description of AT Command for FOTA...................................................................................415
AT+CFOTA Start FOTA service.............................................................................................415
AT+LFOTA Start Local Fota Service.................................................................................. 417
Unsolicited Result Codes......................................................................................................................... 418

AT Commands for SCFOTA..................................................................................................... 419


Overview of AT Commands for SCFOTA...............................................................................................419

www.simcom.com 25 / 483
A76XX Series_AT Command Manual_V1.04

Detailed Description of AT Commands for SCFOTA........................................................................... 419


AT+CAPFOTA Start / Close FOTA service..........................................................................419
AT+CSCFOTA Configure parameters and download upgrade package....................... 420
Command Result Codes.......................................................................................................................... 421
Command Result Report Codes..............................................................................................422
Description of <err>....................................................................................................................422

AT Commands for GNSS..........................................................................................................424


Overview of AT Commands for GNSS................................................................................................... 424
Detailed Description of AT Commands for GNSS................................................................................424
AT+CGNSSPWR GNSS power control............................................................................... 424
AT+CGNSSTST Send data received from UART3 to NMEA port.................................. 425
AT+CGPSCOLD Cold start GPS.......................................................................................... 426
AT+CGPSWARM Warm start GPS.......................................................................................427
AT+CGPSHOT Hot start GPS............................................................................................... 428
AT+CGNSSIPR Configure the baud rate of UART3 and GPS module..........................428
AT+CGNSSMODE Configure GNSS support mode......................................................... 430
AT+CGNSSNMEA Configure NMEA sentence type..........................................................431
AT+CGPSNMEARATE Set NMEA output rate................................................................... 433
AT+CGPSFTM Start GPS test mode........................................................................... 434
AT+CGPSINFO Get GPS fixed position information.................................................435
AT+CGNSSINFO Get GNSS fixed position information...........................................437
AT+CGNSSCMD Send command to GNSS...............................................................439
AT+CGNSSPORTSWITCH Select the output port for NMEA sentence................ 440
AT+CAGPS Get AGPS data from the AGNSS server for assisted positioning.... 441

AT Commands for WIFI.............................................................................................................443


Overview of AT Commands for WIFI...................................................................................................... 444
Detailed Description of AT Commands for WIFI...................................................................................444
AT+CWSTASCAN Scan WIFI network................................................................................ 444
AT+CWSTASCANEX Scan WIFI network extension command......................................445

AT Commands for Bluetooth................................................................................................448


Overview of AT Commands for Bluetooth..............................................................................................448
Detailed Description of AT Commands for Bluetooth.......................................................................... 449
AT+BLEPOWER Power on/off Ble Device..........................................................................449
AT+BLESTATUS Inquiry Current BLE Connect Status.....................................................450
AT+BLEHOST Inquiry and Set Host Device Name........................................................... 451
AT+BLEADDR Inquiry and Set Device Address................................................................... 451
AT+BLESREG Register GATT Server................................................................................. 452
AT+BLESDREG Deregister GATT Server...........................................................................453
AT+BLESSAD Add a Service................................................................................................ 454
AT+BLESSRM Remove a Service........................................................................................455
AT+BLESSCAD Add a Characteristic to an Existed Service........................................... 456
AT+BLESSCRM Remove a Characteristic................................................................. 458
AT+BLESSDAD Add a Descriptor to an Existed Service......................................... 459
AT+BLESSDRM Remove a Descriptor........................................................................460

www.simcom.com 26 / 483
A76XX Series_AT Command Manual_V1.04

AT+BLESSSTART Start a Service............................................................................... 461


AT+BLESSSTOP Stop a Service..................................................................................462
AT+BLESLSTART Start Advertising............................................................................. 464
AT+BLESLSTOP Stop Advertising............................................................................... 465
AT+BLEADV Set Adverting Parameters......................................................................466
AT+BLEDISCONN Disconnect BLE Connection....................................................... 467
AT+BLESIND Send an Indication to a Client..............................................................468
AT+BLESRSP Send a Response to a Client’S Read or Write Operation............. 470
+BLESRREQ Response a read request..................................................................... 471
+BLESWREQ Response a write request....................................................................472
+BLESCON Notify When a Connection’s Status Change...........................................473

Summary of ERROR Codes.................................................................................................... 474


Verbose Codes and Numeric Codes......................................................................................................474
Response String of AT+CEER.................................................................................................................474
Summary of CME ERROR Codes.......................................................................................................... 479
Summary of CMS ERROR Codes.......................................................................................................... 481

www.simcom.com 27 / 483
A76XX Series_AT Command Manual_V1.04

THIS DOCUMENT IS A REFERENCE GUIDE TO ALL THE AT COMMANDS.

Introduction

Scope of the document

This document presents the AT Command Set for SIMCom A76XX Series.

More information about the SIMCom Module which includes the Software Version information can be
retrieved by the command ATI. In this document, a short description, the syntax, the possible setting values
and responses, and some Examples of AT commands are presented.

Prior to using the Module, please read this document and the Version History to know the difference from
the previous document.

In order to implement communication successfully between Customer Application and the Module, it is
recommended to use the AT commands in this document, but not to use some commands which are not
included in this document.

Related documents

[1] A76XX Series_TCPIP_Application_Note


[2] A76XX Series_HTTP(S)_Application_Note
[3] A76XX Series_FTP(S)_Application_Note
[4] A76XX Series_MQTT(S)_Application_Note
[5] A76XX Series_SSL_Application_Note
[6] A76XX Series_AUDIO_Application_Note

You can visit the SIMCom Website for more information by the following link:
http://www.simcom.com

www.simcom.com 28 / 483
A76XX Series_AT Command Manual_V1.04

Terms and Abbreviations

For the purposes of the present document, the following abbreviations apply:

Abbreviation Description
ATtention; the two-character abbreviation is used to start a command
AT
line to be sent from TE/DTE to TA/DCE
DCE Data Communication Equipment
DCS Digital Cellular Network
DTE Data Terminal Equipment
DTMF Dual Tone Multi–Frequency
EDGE Enhanced Data GSM Environment
EGPRS Enhanced General Packet Radio Service
GPIO General–Purpose Input/Output
GPRS General Packet Radio Service
GSM Global System for Mobile communications
HSDPA High Speed Downlink Packet Access
HSUPA High Speed Uplink Packet Access
I2C Inter–Integrated Circuit
IMEI International Mobile station Equipment Identity
IMSI International Mobile Subscriber Identity
ME Mobile Equipment
MO Mobile–Originated
MS Mobile Station
MT Mobile–Terminated; Mobile Termination
PCS Personal Communication System
PDU Protocol Data Unit
PIN Personal Identification Number
PUK Personal Unlock Key
SIM Subscriber Identity Module
SMS Short Message Service
SMS-SC Short Message Service Service Center
TA Terminal Adaptor; e.g. a data card (equal to DCE)
TE Terminal Equipment; e.g. a computer (equal to DTE)
UE User Equipment
UMTS Universal Mobile Telecommunications System
USIM Universal Subscriber Identity Module
WCDMA Wideband Code Division Multiple Access
FTP File Transfer Protocol

www.simcom.com 29 / 483
A76XX Series_AT Command Manual_V1.04

HTTP Hyper Text Transfer Protocol


RTC Real Time Clock
URC Unsolicited Result Code

Definitions and Conventions

1. Definitions

For the purposes of the present document, the following syntactical definitions apply:

 <CR> Carriage return character.

<LF> Linefeed character.


<…> Name enclosed in angle brackets is a syntactical element. Brackets themselves do not
appear in the command line.
[…] Optional subparameter of AT command or an optional part of TA information response is
enclosed in square brackets. Brackets themselves do not appear in the command line. If
subparameter is not given, its value equals to its previous value or the recommended
default value.
underline Underlined and defined subparameter value is the recommended default setting or
factory setting.

 Parameter Saving Mode

NO_SAVE: The parameter of the current AT command will be lost if module is rebooted or current AT
command doesn't have parameter.

AUTO_SAVE: The parameter of the current AT command will be kept in NVRAM automatically and
take in effect immediately, and it won't be lost if module is rebooted.

AUTO_SAVE_REBOOT: The parameter of the current AT command will be kept in NVRAM


automatically and take in effect after reboot, and it won't be lost if module is rebooted.

AT&W_SAVE: The parameter of the current AT command will be kept inusersetting_save.nvm by


sending the command of "AT&W".

 Max Response Time

Max response time is estimated maximum time to get response, the unit is seconds.

2. Document Conventions

 Generally, the characters <CR> and <LF> are intentionally omitted throughout this document.

www.simcom.com 30 / 483
A76XX Series_AT Command Manual_V1.04

 If command response is ERROR, not list the ERROR response inside command syntax.

NOTE

AT commands and responses in figures may be not following above conventions.

AT Interface Synopsis

Interface Settings

Between Customer Application and the Module, standardized RS–232 interface is used for the
communication, and default values for the interface settings as following:
115200bps, 8 bit data, no parity, 1 bit stop, no data stream control.

AT Commands Syntax

The "AT" or "at" or "aT" or "At" prefix must be included at the beginning of each command line (except A/
and +++), and the character <CR> is used to finish a command line so as to issue the command line to the
module. It is recommended that a command line only includes a command.

When Customer Application issues a series of AT commands on separate command lines, leave a pause
between the preceding and the following command until information responses or result codes are retrieved
by Customer Application, for Examples, "OK" is appeared. This advice avoids too many AT commands are
issued at a time without waiting for a response for each command.

The AT Command set implemented by A7600 Series is a combination of 3GPP TS 27.005, 3GPP TS 27.007
and ITU-T recommendation V.25ter and the AT commands developed by SIMCom.

In the present document, AT commands are divided into three categories: Basic Command, S Parameter
Command, and Extended Command.

1. Basic Command
The format of Basic Command is "AT<x><n>" or "AT&<x><n>", where "<x>" is the command name, and

www.simcom.com 31 / 483
A76XX Series_AT Command Manual_V1.04

"<n>" is/are the parameter(s)for the basic command which is optional. An Examples of Basic Command is
"ATE<n>", which informs the TA/DCE whether received characters should be echoed back to the TE/DTE
according to the value of "<n>"; "<n>" is optional and a default value will be used if omitted.

2. S Parameter syntax
The format of S Parameter Command is "ATS<n>=<m>", "<n>" is the index of the S–register to set, and
"<m>" is the value to assign to it. "<m>" is optional; in this case, the format is "ATS<n>", and then a default
value is assigned.

3. Extended Syntax
The Extended Command has several formats, as following table list:

Table 1: Types of AT commands and responses


The mobile equipment returns the list of parameters and value
Test Command
ranges set with the corresponding Write Command or by internal
AT+<x>=?
processes.
Read Command This command returns the currently set value of the parameter or
AT+<x>? parameters.
Write Command
This command sets the user-definable parameter values.
AT+<x>=<…>
Execution Command The execution command reads non-variable parameters affected
AT+<x> by internal processes in the GSM engine.

NOTE

The character "+" between the prefix "AT" and command name may be replaced by other character. For
Examples, using "#" or "$"instead of "+".

4. Combining AT commands on the same Command line


You can enter several AT commands on the same line. In this case, you do not need to type the "AT" or "at"
prefix before every command. Instead, you only need type "AT" or "at" the beginning of the command line.
Please note to use a semicolon as the command delimiter after an extended command; in basic syntax or S
parameter syntax, the semicolon need not enter, for Examples:
ATE1Q0S0=1S3=13V1X4;+IFC=0,0;+IPR=115200.

The Command line buffer can accept a maximum of 3071 characters (counted from the first command
without "AT" or "at" prefix). If the characters entered exceeded this number then none of the Command will
executed and TA will return "ERROR".

5. Entering successive AT commands on separate lines


When you need to enter a series of AT commands on separate lines, please Note that you need to wait the
final response (for Examples OK, CME error, CMS error)of last AT Command you entered before you enter
www.simcom.com 32 / 483
A76XX Series_AT Command Manual_V1.04

the next AT Command.

Supported character sets

The A7600 Series AT Command interface defaults to the IRA character set. The A7600 Series supports the
following character sets:
GSM format
UCS2
IRA
The character set can be set and interrogated using the "AT+CSCS" Command (3GPP TS 27.007). The
character set is defined in GSM specification 3GPP TS 27.005.

The character set affects transmission and reception of SMS and SMS Cell Broadcast messages, the entry
and display of phone book entries text field and SIM Application Toolkit alpha strings.

www.simcom.com 33 / 483
A76XX Series_AT Command Manual_V1.04

AT Commands According to
V.25TER

Overview of AT Commands According to V.25TER

Command Description
ATD Mobile originated call to dial a number
ATA Call answer
ATH Disconnect existing call
ATS0 Automatic answer incoming call
+++ Switch from data mode to command mode
ATO Switch from command mode to data mode
ATI Display product identification information
ATE Enable command echo
AT&V Display current configuration
ATV Set result code format mode
AT&F Set all current parameters to manufacturer defaults
ATQ Set Result Code Presentation Mode
ATX Set CONNECT Result Code Forma
AT&W Save the user setting to ME
ATZ Restore the user setting from ME
AT+CGMI Request manufacturer identification
AT+CGMM Request model identification
AT+CGMR Request revision identification
AT+CGSN Request product serial number identification
AT+CSCS Select TE character set
AT+GCAP Request overall capabilities

Detailed Description of AT Commands for V.25TER

www.simcom.com 34 / 483
A76XX Series_AT Command Manual_V1.04

ATD Mobile originated call to dial a number

This command is used to list characters that may be used in a dialling string for making a call or controlling
supplementary services.

ATD Mobile originated call to dial a number


Response
Originate a voice call successfully:
OK

VOICE CALL: BEGIN


Originate a data call successfully:
CONNECT [<text>]
Execution Command
ATD<n>[<mgsm][;] Originate a call unsuccessfully during command execution:
ERROR

Originate a call unsuccessfully for failed connection recovery:


NO CARRIER

Originate a call unsuccessfully for error related to the MT:


+CME ERROR: <err>
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<n> String of dialing digits and optionally V.25ter modifiers dialing digits:
0-9,*, #,+,A,B,C
Following V.25ter modifiers are ignored:
,(comma),T,P,!,W,@
Emergency call:
<n> Standardized emergency number 112 (no SIM needed)
<mgsm> String of GSM modifiers:
I Actives CLIR (Disables presentation of own number to called party)
i Deactivates CLIR (Enable presentation of own number to called
party)
G Activates Closed User Group invocation for this call only
g Deactivates Closed User Group invocation for this call only
<;> The termination character ";" is mandatory to set up voice calls. It must
not be used for data and fax calls.
<text> CONNECT result code string; the string formats please refer ATX
www.simcom.com 35 / 483
A76XX Series_AT Command Manual_V1.04

command.
<err> Service failure result code string; the string formats please refer +CME
ERROR result code and AT+CMEE command.

Examples

ATD10086;
OK

VOICE CALL: BEGIN

NOTE

1. Support several "P" or "p" in the DTMF string but the valid auto-sending DTMF after characters "P" or
"p" should not be more than 29.
2. Auto-sending DTMF after character "P" or "p" should be ASCII character in the set 0-9, *, #.

ATA Call answer

This command is used to make remote station to go off-hook, e.g. answer an incoming call. If there is no an
incoming call and entering this command to TA, it will be return "NO CARRIER" to TA.

ATA Call answer


Response
1)For voice call:
OK

Execution Command
VOICE CALL: BEGIN
ATA
2)For data call, and TA switches to data mode:
CONNECT
3)No connection or no incoming call:
NO CARRIER
Parameter Saving Mode -
Max Response Time -
Reference -

Examples

www.simcom.com 36 / 483
A76XX Series_AT Command Manual_V1.04

ATA
OK

VOICE CALL: BEGIN

NOTE

If there is an incoming call and not connected,unsolicited result code RING will report every six
seconds.

ATH Disconnect existing call

This command is used to disconnect existing call. Before using ATH command to hang up a voice call, it
must set AT+CVHU=0. Otherwise, ATH command will be ignored and "OK" response is given only.
This command is also used to disconnect PS data call, and in this case it doesn’t depend on the value of
AT+CVHU.

ATH Disconnect existing call


Response
If AT+CVHU=0:
Execution Command
OK
ATH

VOICE CALL: END: <time>


Parameter Saving Mode -
Max Response Time -
Reference -

Examples

AT+CVHU=0
OK
ATH
OK

VOICE CALL: END: 000017

www.simcom.com 37 / 483
A76XX Series_AT Command Manual_V1.04

ATS0 Automatic answer incoming call

The S-parameter command controls the automatic answering feature of the Module. If set to 000, automatic
answering is disabled, otherwise it causes the Module to answer when the incoming call indication
(RING)has occurred the number of times indicated by the specified value; and the setting will not be stored
upon power-off, i.e. the default value will be restored after restart.

ATS0 Automatic answer incoming call


Response
1)
<n>
Read Command
ATS0?
OK
2)
ERROR
Response
1)
Write Command
OK
ATS0=<n>
2)
ERROR
Parameter Saving Mode AT&W_SAVE
Max Response Time -
Reference -

Defined Values

<n> 000 Automatic answering mode is disable.


001–255 Enable automatic answering on the ring number specified.

Examples

ATS0=003
OK
ATS0?
000

OK

NOTE

www.simcom.com 38 / 483
A76XX Series_AT Command Manual_V1.04

The S-parameter command is effective on voice call and data call.


If <n> is set too high, the remote party may hang up before the call can be answered automatically.

+++ Switch from data mode to command mode

This command is only available during a connecting PS data call. The +++ character sequence causes the
TA to cancel the data flow over the AT interface and switch to Command Mode. This allows to enter AT
commands while maintaining the data connection to the remote device.

+++ Switch from data mode to command mode


Execution Command Response
+++ OK
Parameter Saving Mode -
Max Response Time -
Reference -

Examples

+++
OK

NOTE

To prevent the +++ escape sequence from being misinterpreted as data, it must be preceded and
followed by a pause of at least 1000 milliseconds, and the interval between two ‘+’ character can’t
exceed 900 milliseconds.

ATO Switch from command mode to data mode

ATO is the corresponding command to the +++ escape sequence. When there is a PS data call connected
and the TA is in Command Mode, ATO causes the TA to resume the data and takes back to Data Mode.

ATO Switch from command mode to data mode

www.simcom.com 39 / 483
A76XX Series_AT Command Manual_V1.04

Response
1)TA/DCE switches to Data Mode from Command Mode:
CONNECT [<baud rate>]
Execution Command
2)If connection is not successfully resumed:
ATO
NO CARRIER
3)
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Examples

ATO
CONNECT 115200

ATI Display product identification information

This command is used to request the product information, which consists of manufacturer identification,
model identification, revision identification, International Mobile station Equipment Identity (IMEI)and overall
capabilities of the product.

ATI Display product identification information


Response
Manufacturer: <manufacturer>
Model: <model>
Execution Command Revision: <revision>
ATI IMEI: <sn>
+GCAP: list of <name>s

OK
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<manufacturer> The identification of manufacturer.


<model> The identification of model.

www.simcom.com 40 / 483
A76XX Series_AT Command Manual_V1.04

<revision> The revision identification of firmware.


<sn> Serial number identification, which consists of a single line containing
IMEI (International Mobile station Equipment Identity)number.
<name> List of additional capabilities:
+CGSM GSM function is supported
+FCLASS FAX function is supported
+DS Data compression is supported
+ES Synchronous data mode is supported.
+CIS707-A CDMA data service command set
+CIS-856 EVDO data service command set
+MS Mobile Specific command set

Examples

ATI
Manufacturer: INCORPORATED
Model: A7600C
Revision: A7600C_V1.0
IMEI: 351602000330570
+GCAP: +CGSM,+FCLASS,+DS

OK

ATE Enable command echo

This command sets whether or not the TA echoes characters.

ATE Enable command echo


Response
1)if format is right
Execution Command
OK
ATE[<value>]
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 120000ms
Reference -

Defined Values

<value> 0 Echo mode off


www.simcom.com 41 / 483
A76XX Series_AT Command Manual_V1.04

1 Echo mode on

Examples

ATE1
OK
ATE0
OK

AT&V Display current configuration

This command returns some of the base configuration parameters settings.

AT&V Display current configuration


Response
1)
<TEXT>
Execution Command
AT&V
OK
2)
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<TEXT> All relative configuration information.

Examples

AT&V
&C: 1; &D: 0; &F: 0; &W: 0; E: 1; Q: 0; V: 1; X: 0; Z: 0; S0: 0; S2: 43; S3: 13; S4: 10; S5: 8; S6: 2;
S7: 1; S8: 2; S9: 6; S10: 7; S11: 63; S30: 10; +FCLASS: 0; +IPR: 115200; +IPREX: 115200;
+CSCS: IRA; +CREG: 0; +CGREG: 0; +CEREG: 0; +CGDCONT:
(1,"IP","ctnet.mnc011.mcc460.gprs","10.13.204.244",0,0,,,,),(2,"IP","CMNET"); +CGDSCONT: ;
+CGEQMIN: (1,0,256000,256000,256000,256000,2,1520,"0E0,6E8,",3,150,0,0,0);
+CGQMIN:(1,3,4,5,1,1),(2,3,4,5,1,1); +CGEREP: (2,0); +CGCLASS: "A"; +CGACT: (1,1),(2,0);

www.simcom.com 42 / 483
A76XX Series_AT Command Manual_V1.04

+CGAUTH: (1,0),(2,0); +CPBS: "SM"; +CMEE: 2; +CFUN: 1; +CMGF: 0; +CSCA:


("+316540942000",145); +CSMP: 33,167,0,0; +CSDH: 0; +CPMS:
"SM",0,50,"SM",0,50,"SM",0,50;

OK

ATV Set result code format mode

This parameter setting determines the contents of the header and trailer transmitted with result codes and
information responses.

ATV Set result code format mode


Response
1)if <value>=0
Write Command
0
ATV[<value>]
2)If <value>=1
OK
Parameter Saving Mode AT&W_SAVE
Max Response Time -
Reference -

Defined Values

<value> 0 Information response: <text><CR><LF>


Short result code format: <numeric code><CR>
1 Information response: <CR><LF><text><CR><LF>
Long result code format: <CR><LF><verbose
code><CR><LF>

Examples

ATV1
OK

NOTE

In case of using This command without parameter <value> will be set to 1.

www.simcom.com 43 / 483
A76XX Series_AT Command Manual_V1.04

AT&F Set all current parameters to manufacturer defaults

This command is used to set all current parameters to the manufacturer defined profile.
Every ongoing or incoming call will be terminated.

AT&F Set all current parameters to manufacturer defaults


Execution Command Response
AT&F[<value>] OK
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<value> 0 Set some temporary TA parameters to manufacturer defaults.


The setting after power on or reset is same as value 0.
default values
TA parameters VALUE
AT+CATR 0
AT+CNMP 2
AT+CTZU 0
AT+CVAUXV 2850

Examples

AT&F
OK

NOTE

List of parameters reset to manufacturer default can be found in Defined Values, factory default settings
restorable with AT&F[<value>].

ATQ Set Result Code Presentation Mode

www.simcom.com 44 / 483
A76XX Series_AT Command Manual_V1.04

Specify whether the TA transmits any result code to the TE or not. Text information transmitted in response
is not affected by this setting

ATQ Set Result Code Presentation Mode


Response
1)If <n>=0:
Write Command
OK
ATQ<n>
2)If <n>=1:
No Responses
Response
1)Set default value:0
Execution Command
OK
ATQ
2)
No Responses
Parameter Saving Mode AT&W_SAVE
Max Response Time -
Reference -

Defined Values

<n> 0 DCE transmits result code


1 DCE not transmits result code

Examples

ATQ0
OK
ATQ
OK

ATX Set CONNECT Result Code Format

This parameter setting determines whether the TA transmits unsolicited result codes or not. The unsolicited
result codes are <CONNECT><SPEED><COMMUNICATION PROTOCOL>[<TEXT>]

ATX Set CONNECT Result Code Format


Response
Write Command
1)
ATX<VALUE>
OK

www.simcom.com 45 / 483
A76XX Series_AT Command Manual_V1.04

2)
ERROR
Response
1)Set default value:1
Execution Command
OK
ATX
2)
ERROR
Parameter Saving Mode AT&W_SAVE
Max Response Time -
Reference -

Defined Values

<value> 0 CONNECT result code returned


1,2,3,4 May be transmits extern result codes.

Examples

ATX1
OK
ATX
OK

AT&W Save the user setting to ME

This command will save the user settings to ME which set by ATE, ATQ, ATV, ATX, AT&C, AT&D, AT+IFC
and ATS0.After restarted, the value saved by AT&W must be restored by ATZ.

AT&W Save the user setting to ME


Response
1)
Write Command
OK
AT&W<value>
2)
ERROR
Response
1)Set default value: 0
Execution Command
OK
AT&W
2)
ERROR

www.simcom.com 46 / 483
A76XX Series_AT Command Manual_V1.04

Parameter Saving Mode -


Max Response Time -
Reference -

Defined Values

<value> 0 Save

Examples

AT&W0
OK
AT&W
OK

ATZ Restore the user setting from ME

This command will restore the user setting from ME which set by ATE, ATQ, ATV, ATX, AT&C, AT&D and
ATS0.

ATZ Restore the user setting from ME


Response
1)
Write Command
OK
ATZ<value>
2)
ERROR
Response
1)Set default value: 0
Execution Command
OK
ATZ
2)
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<value> 0 Restore

www.simcom.com 47 / 483
A76XX Series_AT Command Manual_V1.04

Examples

ATZ0
OK
ATZ
OK

AT+CGMI Request manufacturer identification

This command is used to request the manufacturer identification text, which is intended to permit the user of
the Module to identify the manufacturer.

AT+CGMI Request manufacturer identification


Test Command Response
AT+CGMI=? OK
Response
Execution Command <manufacturer>
AT+CGMI
OK
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<manufacturer> The identification of manufacturer.

Examples

AT+CGMI
INCORPORATED

OK
AT+CGMI=?
OK

www.simcom.com 48 / 483
A76XX Series_AT Command Manual_V1.04

AT+CGMM Request model identification

This command is used to requests model identification text, which is intended to permit the user of the
Module to identify the specific model.

AT+CGMM Request model identification


Test Command Response
AT+CGMM=? OK
Response
Execution Command <model>
AT+CGMM
OK
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<model> The identification of model.

Examples

AT+CGMM
A7600E

OK
AT+CGMM=?
OK

AT+CGMR Request revision identification

This command is used to request product firmware revision identification text, which is intended to permit
the user of the Module to identify the version.

AT+CGMR Request revision identification


Test Command Response
AT+CGMR=? OK
Execution Command Response

www.simcom.com 49 / 483
A76XX Series_AT Command Manual_V1.04

AT+CGMR +CGMR: <revision>

OK
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<revision> The revision identification of firmware.

Examples

AT+CGMR
+CGMR: A35B01A7600C

OK
AT+CGMR=?
OK

AT+CGSN Request product serial number identification

This command requests product serial number identification text, which is intended to permit the user of the
Module to identify the individual ME to which it is connected to.

AT+CGSN Request product serial number identification


Test Command Response
AT+CGSN=? OK
Response
<sn>

OK
Execution Command
AT+CGSN
If there is any error, response
ERROR
or
+CME ERROR :<err>
Parameter Saving Mode -

www.simcom.com 50 / 483
A76XX Series_AT Command Manual_V1.04

Max Response Time -


Reference -

Defined Values

<sn> Serial number identification, which consists of a single line containing


the IMEI (International Mobile station Equipment Identity)number of
the MT.

Examples

AT+CGSN
351602000330570

OK
AT+CGSN=?
OK

AT+CSCS Select TE character set

Write command informs TA which character set <chest> is used by the TE. TA is then able to convert
character strings correctly between TE and MT character sets.
Read command shows current setting and test command displays conversion schemes implemented in the
TA.

AT+CSCS Select TE character set


Response
Test Command +CSCS: (list of supported <chset>s)
AT+CSCS=?
OK
Response
Read Command +CSCS: <chset>
AT+CSCS?
OK
Response
Write Command OK
AT+CSCS=<chset> or
ERROR
Execution Command Response
AT+CSCS Set subparameters as default value(IRA):
www.simcom.com 51 / 483
A76XX Series_AT Command Manual_V1.04

OK
Parameter Saving Mode AUTO_SAVE
Max Response Time -
Reference -

Defined Values

<chest> Character set, the definition as following:


"IRA" International reference alphabet.
"GSM" GSM default alphabet; this setting causes easily
software flow control (XON /XOFF)problems.
"UCS2" 16-bit universal multiple-octet coded character set;
UCS2 character strings are converted to
hexadecimal numbers from 0000 to FFFF.

Examples

AT+CSCS="IRA"
OK
AT+CSCS?
+CSCS:"IRA"

OK
AT+CSCS=?
+CSCS: ("IRA","UCS2","GSM")

OK
AT+CSCS
OK

AT+GCAP Request overall capabilities

Execution command causes the TA reports a list of additional capabilities.

AT+GCAP Request overall capabilities


Response
Test Command 1)
AT+GCAP=? OK
2)

www.simcom.com 52 / 483
A76XX Series_AT Command Manual_V1.04

ERROR
Response
1)
+GCAP: (list of <name>s)
Execution Command
AT+GCAP
OK
2)
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<name> List of additional capabilities.


+CGSM GSM function is supported
+FCLASS FAX function is supported
+DS Data compression is supported
+ES Synchronous data mode is supported.
+CIS707-A CDMA data service command set
+CIS-856 EVDO data service command set
+MS Mobile Specific command set

Examples

AT+GCAP
+GCAP: +CGSM,+FCLASS,+DS

OK
AT+GCAP=?
OK

www.simcom.com 53 / 483
A76XX Series_AT Command Manual_V1.04

AT Commands for Status Control


Overview of AT Commands for Status Control

Command Description
AT+CFUN Set phone functionality
AT+CSQ Query signal quality
AT+AUTOCSQ Set CSQ report
AT+CSQDELTA Set RSSI delta change threshold
AT+CPOF Power down the module
AT+CRESET Reset the module
AT+CACM Accumulated call meter
AT+CAMM Accumulated call meter maximum
AT+CPUC Price per unit and currency table
AT+CCLK Real time clock management
AT+CMEE Report mobile equipment error
AT+CPAS Phone activity status
AT+SIMEI Set IMEI for the module

Detailed Description of AT Commands for Status Control

AT+CFUN Set phone functionality

This command is used to select the level of functionality <fun> in the ME. Level "full functionality" is where
the highest level of power is drawn. "Minimum functionality" is where minimum power is drawn. Level of
functionality between these may also be specified by manufacturers. When supported by manufacturers,
ME resetting with <rst> parameter may be utilized.

AT+CFUN Set phone functionality


Response
Test Command
+CFUN: (range of supported <fun>s),(range of supported <rst>s)
AT+CFUN=?

www.simcom.com 54 / 483
A76XX Series_AT Command Manual_V1.04

OK
Response
1)
+CFUN: <fun>

Read Command
OK
AT+CFUN?
2)
ERROR
3)
+CME ERROR: <err>
Response
1)
OK
Write Command
2)
AT+CFUN=<fun>[,<rst>]
ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<fun> 0 minimum functionality


1 full functionality, online mode
4 disable phone both transmit and receive RF circuits
5 Factory Test Mode (The A7600's 5 and 1 have the same function)
6 Reset
7 Offline Mode
<rst> 0 do not reset the ME before setting it to <fun> power level
1 reset the ME before setting it to <fun> power level. This value only
takes effect when <fun> equals 1.

Examples

AT+CFUN=?
+CFUN: (0-1,4-7),(0-1)

OK
AT+CFUN?
+CFUN: 1

OK

www.simcom.com 55 / 483
A76XX Series_AT Command Manual_V1.04

AT+CFUN=1
OK

NOTE

AT+CFUN=6 must be used after setting AT+CFUN=7. If module in offline mode, must execute
AT+CFUN=6 or restart module to online mode.

AT+CSQ Query signal quality

This command is used to return received signal strength indication <rssi> and channel bit error rate <ber>
from the ME. Test command returns values supported by the TA as compound values.

AT+CSQ Query signal quality


Response
Test Command +CSQ: (range of supported <rssi>s),(range of supported <ber>s)
AT+CSQ=?
OK
Response
1)
+CSQ: <rssi>,<ber>
Execution Command
AT+CSQ
OK
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<rssi> 0 -113 dBm or less


1 -111 dBm
2 -109 dBm
30 -53 dBm
31 -51 dBm or greater
99 not known or not detectable
<ber> (in percent)
0 <0.01%
www.simcom.com 56 / 483
A76XX Series_AT Command Manual_V1.04

1 0.01% --- 0.1%


2 0.1% --- 0.5%
3 0.5% --- 1.0%
4 1.0% --- 2.0%
5 2.0% --- 4.0%
6 4.0% --- 8.0%
7 >=8.0%
99 not known or not detectable

Examples

AT+CSQ=?
+CSQ: (0-31,99),(0-7,99)

OK
AT+CSQ
+CSQ: 31,99

OK

AT+AUTOCSQ Set CSQ report

This command is used to enable or disable automatic report CSQ information, when automatic report
enabled, the module reports CSQ information every five seconds or only after <rssi> or <ber> is changed,
the format of automatic report is "+CSQ: <rssi>,<ber>".

AT+AUTOCSQ Set CSQ report


Response
+AUTOCSQ: (range of supported<auto>s),(range of
Test Command
supported<mode>s)
AT+AUTOCSQ=?

OK
Response
Read Command +AUTOCSQ: <auto>,<mode>
AT+AUTOCSQ?
OK
Response
Write Command 1)
AT+AUTOCSQ=<auto>[,<mo OK
de>] 2)
ERROR

www.simcom.com 57 / 483
A76XX Series_AT Command Manual_V1.04

Parameter Saving Mode NO_SAVE


Max Response Time 9000ms
Reference Vendor

Defined Values

<auto> 0 disable automatic report


1 enable automatic report
<mode> 0 CSQ automatic report every five seconds
1 CSQ automatic report only after <rssi> or <ber> is changed.

NOTE: If the parameter of <mode> is omitted when executing write


command,<mode> will be set to default value.

Examples

AT+AUTOCSQ=?
+AUTOCSQ: (0-1),(0-1)

OK
AT+AUTOCSQ?
+AUTOCSQ: 0,0

OK
AT+AUTOCSQ=1
OK

AT+CSQDELTA Set RSSI delta change threshold

This command is used to set RSSI delta threshold for signal strength reporting.

AT+CSQDELTA Set RSSI delta change threshold


Response
Test Command +CSQDELTA: (list of supported <delta>s)
AT+CSQDELTA=?
OK
Response
Read Command 1)
AT+CSQDELTA? +CSQDELTA: <delta>

www.simcom.com 58 / 483
A76XX Series_AT Command Manual_V1.04

OK
2)
ERROR
Response
1)
Write Command
OK
AT+CSQDELTA=<delta>
2)
ERROR
Response
Execution Command
Set default value(<delta>=5)
AT+CSQDELTA
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference Vendor

Defined Values

<delta> Range: from 0 to 5.

Examples

AT+CSQDELTA=?
+CSQDELTA: (0-5)

OK
AT+CSQDELTA?
+CSQDELTA: 5

OK
AT+CSQDELTA
OK

AT+CPOF Power down the module

This command is used to power off the module. Once the AT+CPOF command is executed, The module will
store user data and deactivate from network, and then shutdown.

AT+CPOF Power down the module


Test Command Response
AT+CPOF=? OK
www.simcom.com 59 / 483
A76XX Series_AT Command Manual_V1.04

Execution Command Response


AT+CPOF OK
Parameter Saving Mode -
Max Response Time 9000ms
Reference Vendor

Examples

AT+CPOF=?
OK
AT+CPOF
OK

AT+CRESET Reset the module

This command is used to reset the module.

AT+CRESET Reset the module


Execution Command Response
AT+CRESET OK
Test Command Response
AT+CRESET=? OK
Parameter Saving Mode -
Max Response Time 9000ms
Reference Vendor

Examples

AT+CRESET=?
OK
AT+CRESET
OK

AT+CACM Accumulated call meter

This command is used to reset the Advice of Charge related accumulated call meter value in SIM file EFACM.

www.simcom.com 60 / 483
A76XX Series_AT Command Manual_V1.04

AT+CACM Accumulated call meter


Response
1)
Test Command
OK
AT+CACM=?
2)
ERROR
Response
1)
+CACM: <acm>

Read Command
OK
AT+CACM?
2)
ERROR
3)
+CME ERROR: <err>
Response
1)
OK
Write Command
2)
AT+CACM=<passwd>
ERROR
3)
+CME ERROR: <err>
Response
1)
OK
Execution Command
2)
AT+CACM
ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<passwd> String type, SIM PIN2.


<acm> String type, accumulated call meter value similarly coded as <ccm>
under +CAOC.

Examples

AT+CACM=?
OK
www.simcom.com 61 / 483
A76XX Series_AT Command Manual_V1.04

AT+CACM?
+CACM: "000000"

OK
AT+CACM="000000"
+CME ERROR: SIM PUK2 required

AT+CACM
+CME ERROR: SIM PIN required

AT+CAMM Accumulated call meter maximum

This command is used to set the Advice of Charge related accumulated call meter maximum value in SIM
file EFACMmax.

AT+CAMM Accumulated call meter maximum


Response
1)
Test Command
OK
AT+CAMM=?
2)
ERROR
1)
+CAMM: <acmmax>

Read Command OK
AT+CAMM? 2)
ERROR
3)
+CME ERROR: <err>
Response
1)
Write Command OK
AT+CAMM=<acmmax>[,<pas 2)
swd>] ERROR
3)
+CME ERROR: <err>
1)
OK
Execution Command 2)
AT+CAMM ERROR
3)
+CME ERROR: <err>

www.simcom.com 62 / 483
A76XX Series_AT Command Manual_V1.04

Parameter Saving Mode NO_SAVE


Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<acmmax> String type, accumulated call meter maximum value similarly coded as
<ccm> under AT+CAOC, value zero disables ACMmax feature.
<passwd> String type, SIM PIN2.

Examples

AT+CAMM=?
OK
AT+CAMM?
+CAMM: "000000"

OK
AT+CAMM="000000"
+CME ERROR: SIM PIN required
AT+CAMM
+CME ERROR: SIM PIN required

AT+CPUC Price per unit and currency table

This command is used to set the parameters of Advice of Charge related price per unit and currency table in
SIM file EFPUCT.

AT+CPUC Price per unit and currency table


Response
1)
Test Command
OK
AT+CPUC=?
2)
ERROR
Response
1)
Read Command +CPUC: [<currency>,<ppu>]
AT+CPUC?
OK
2)
www.simcom.com 63 / 483
A76XX Series_AT Command Manual_V1.04

ERROR
3)
+CME ERROR: <err>
Response
1)
Write Command OK
AT+CPUC=<currency>,<ppu 2)
>[,<passwd>] ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<currency> String type, three-character currency code (e.g. "GBP", "DEM"),


character set as specified by command Select TE Character Set
AT+CSCS.
<ppu> String type, price per unit, dot is used as a decimal separator. (e.g.
"2.66").
<passwd> String type, SIM PIN2

Examples

AT+CPUC=?
OK
AT+CPUC?
+CPUC: "","0.000000"

OK
AT+CPUC="1","0.000000"
+CME ERROR: SIM PIN required

AT+CCLK Real time clock management

This command is used to manage Real Time Clock of the module.

AT+CCLK Real time clock management


Test Command Response
www.simcom.com 64 / 483
A76XX Series_AT Command Manual_V1.04

AT+CCLK=? OK
Response
Read Command +CCLK: <time>
AT+CCLK?
OK
Response
1)
Write Command
OK
AT+CCLK=<time>
2)
ERROR
Parameter Saving Mode NO_SAVE
Maximum Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<time> String type value; format is "yy/MM/dd,hh:mm:ss±zz", where


characters indicate year (two last digits), month, day, hour, minutes,
seconds and time zone (indicates the difference, expressed in
quarters of an hour, between the local time and GMT; three last digits
are mandatory, range (-96 to 96). E.g. 6th of May 2008, 14:28:10
GMT+8 equals to "08/05/06,14:28:10+32".
NOTE: 1. Time zone is nonvolatile, and the factory value is invalid time
zone.
2. Command +CCLK? will return time zone when time zone is
valid, and if time zone is 00, command +CCLK? will return "+00", but
not "-00".

Examples

AT+CCLK=?
OK
AT+CCLK?
+CCLK: "14/01/01,02:14:36+08"

OK
AT+CCLK="14/01/01,02:14:36+08"
OK

www.simcom.com 65 / 483
A76XX Series_AT Command Manual_V1.04

AT+CMEE Report mobile equipment error

This command is used to disable or enable the use of result code "+CME ERROR: <err>" or "+CMS
ERROR: <err>" as an indication of an error relating to the functionality of ME; when enabled, the format of
<err> can be set to numeric or verbose string.

AT+CMEE Report mobile equipment error


Response
Test Command +CMEE: (list of supported <n>s)
AT+CMEE=?
OK
Response
Read Command +CMEE: <n>
AT+CMEE?
OK
Response
1)
Write Command
OK
AT+CMEE=<n>
2)
ERROR
Execution Command Response
AT+CMEE OK
Note: Set default value
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<n> 0 Disable result code,i.e. only "ERROR" will be displayed.


1 Enable error result code with numeric values.
2 Enable error result code with string values.

Examples

AT+CMEE=?
+CMEE: (0-2)
AT+CMEE?
+CMEE: 2

OK
AT+CMEE=2

www.simcom.com 66 / 483
A76XX Series_AT Command Manual_V1.04

OK

AT+CPAS Phone activity status

This command is used to return the activity status <pas> of the ME. It can be used to interrogate the ME
before requesting action from the phone.

AT+CPAS Phone activity status


Response
Test Command +CPAS: (list of supported <pas>s)
AT+CPAS=?
OK
Response
Execution Command +CPAS: <pas>
AT+CPAS
OK
Parameter Saving Mode -
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<pas> 0 ready (ME allows commands from TA/TE)


3 ringing (ME is ready for commands from TA/TE, but the ringer is
active)
4 call in progress (ME is ready for commands from TA/TE, but a call
is in progress)

Examples

AT+CPAS=?
+CPAS: (0,3,4)

OK
AT+CPAS
+CPAS: 0

OK

NOTE
www.simcom.com 67 / 483
A76XX Series_AT Command Manual_V1.04

This command is same as AT+CLCC, but AT+CLCC is more commonly used. So AT+CLCC is
recommended to use.

AT+SIMEI Set the IMEI for the module

This command is used to set the module’s IMEI value.

AT+SIMEI Set the IMEI for the module


Test Command Response
AT+SIMEI=? OK
Response
1)
+SIMEI: <imei>
Read Command
AT+SIMEI?
OK
2)
ERROR
Response
1)
Write Command
OK
AT+SIMEI=<imei>
2)
ERROR
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference Vendor

Defined Values

<imei> The 15-digit IMEI value.

Examples

AT+SIMEI=?
OK
AT+SIMEI?
+SIMEI: 357396012183175

OK
www.simcom.com 68 / 483
A76XX Series_AT Command Manual_V1.04

AT+SIMEI=357396012183175
OK

www.simcom.com 69 / 483
A76XX Series_AT Command Manual_V1.04

AT Commands for Network


Overview of AT Commands for Network

Command Description
AT+CREG Network registration
AT+COPS Operator selection
AT+CUSD Unstructured supplementary service data
AT+CSSN Supplementary service notifications
AT+CPOL Preferred operator list
AT+COPN Read operator names
AT+CNMP Preferred mode selection
AT+CNBP Preferred band selection
AT+CPSI Inquiring UE system information
AT+CNSMOD Show network system mode
AT+CTZU Automatic time and time zone update
AT+CTZR Time and time zone reporting

Detailed Description of AT Commands for Network

AT+CREG Network registration

This command is used to control the presentation of an unsolicited result code +CREG: <stat> when <n>=1
and there is a change in the ME network registration status, or code +CREG: <stat>[,<lac>,<ci>] when
<n>=2 and there is a change of the network cell.

Read command returns the status of result code presentation and an integer <stat> which shows whether
the network has currently indicated the registration of the ME. Location information elements <lac> and <ci>
are returned only when <n>=2 and ME is registered in the network.

AT+CREG Network registration


Test Command Response
www.simcom.com 70 / 483
A76XX Series_AT Command Manual_V1.04

AT+CREG=? +CREG: (range of supported <n>s)

OK
Response
1)
+CREG: <n>,<stat>[,<lac>,<ci>]

Read Command
OK
AT+CREG?
2)
ERROR
3)
+CME ERROR: <err>
Response
1)
OK
Write Command
2)
AT+CREG=<n>
ERROR
3)
+CME ERROR: <err>
Response
Execution Command
Set default value(<n>=0):
AT+CREG
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<n> 0 disable network registration unsolicited result code.


1 enable network registration unsolicited result code +CREG: <stat>.
2 enable network registration and location information unsolicited
result code +CREG: <stat>[,<lac>,<ci>].
<stat> 0 not registered, ME is not currently searching a new operator to
register to.
1 registered, home network.
2 not registered, but ME is currently searching a new operator to
register to.
3 registration denied.
4 unknown.
5 registered, roaming.
6 registered for "SMS only", home network (applicable only when
E-UTRAN)
<lac> Two byte location area code in hexadecimal format(e.g."00C3" equals
193 in decimal).

www.simcom.com 71 / 483
A76XX Series_AT Command Manual_V1.04

<ci> Cell Identify in hexadecimal format.


GSM: Maximum is two byte.
WCDMA: Maximum is four byte.

Examples

AT+CREG=?
+CREG: (0-2)

OK
AT+CREG?
+CREG: 0,1

OK
AT+CREG=1
OK
AT+CREG
OK

AT+COPS Operator selection

Write command forces an attempt to select and register the GSM/UMTS network operator. <mode> is used
to select whether the selection is done automatically by the ME or is forced by this command to operator
<oper> (it shall be given in format <format>). If the selected operator is not available, no other operator shall
be selected (except <mode>=4). The selected operator name format shall apply to further read commands
(AT+COPS?)also. <mode>=2 forces an attempt to deregister from the network. The selected mode affects
to all further network registration (e.g. after <mode>=2, ME shall be unregistered until <mode>=0 or 1 is
selected).

Read command returns the current mode and the currently selected operator. If no operator is
selected,<format> and <oper> are omitted.

Test command returns a list of quadruplets, each representing an operator present in the network.
Quadruplet consists of an integer indicating the availability of the operator <stat>, long and short
alphanumeric format of the name of the operator, and numeric format representation of the operator. Any of
the formats may be unavailable and should then be an empty field. The list of operators shall be in order:
home network, networks referenced in SIM, and other networks.

It is recommended (although optional)that after the operator list TA returns lists of supported <mode>s and
<format>s. These lists shall be delimited from the operator list by two commas.

www.simcom.com 72 / 483
A76XX Series_AT Command Manual_V1.04

AT+COPS Operator selection


Response
1)
[+COPS: [list of supported (<stat>,long alphanumeric <oper>,short
alphanumeric <oper>,numeric <oper>[,<AcT>])s]
[,,(list of supported <mode>s),(list of supported <format>s)]]
Test Command
AT+COPS=?
OK
2)
ERROR
3)
+CME ERROR: <err>
Response
1)
+COPS: <mode>[,<format>,<oper>[,<AcT>]]

Read Command
OK
AT+COPS?
2)
ERROR
3)
+CME ERROR: <err>
Response
1)
Write Command OK
AT+COPS=<mode>[,<format 2)
>[,<oper>[,<AcT>]]] ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 60S
Reference 3GPP TS 27.007

Defined Values

<mode> 0 automatic
1 manual
2 force deregister
3 set only <format>
4 manual/automatic
NOTE: if <mode> is set to 1, 4 in write command, the <oper> is
needed.
<format> 0 long format alphanumeric <oper>
1 short format alphanumeric <oper>
2 numeric <oper>

www.simcom.com 73 / 483
A76XX Series_AT Command Manual_V1.04

<oper> string type,<format> indicates if the format is alphanumeric or


numeric.
<stat> 0 unknown
1 available
2 current
3 forbidden
<AcT> Access technology selected
0 GSM
1 GSM Compact
2 UTRAN
3 GSM w/EGPRS
4 UTRAN w/HSDPA
5 UTRAN w/HSUPA
6 UTRAN w/HSDPA and HSUPA
7 EUTRAN
8 UTRAN HSPA+

Examples

AT+COPS=?
+COPS: (2,"CHN-UNICOM","UNICOM","46001",7),(1,"CHN-UNICOM","UNICOM",
"46001",2),(1,"CHN-UNICOM","UNICOM","46001",0),(3,"CHINA MOBILE","CMCC",
"46000",7),(3,"CHN-CT","CT","46011",7),(3,"CHINA MOBILE","CMCC","46000",
0),,(0,1,2,3,4),(0,1,2)

OK
AT+COPS?
+COPS: 0,2,"46001",7

OK
AT+COPS=0,2,"46001",7
OK

AT+CUSD Unstructured supplementary service data

This command allows control of the Unstructured Supplementary Service Data (USSD). Both network and
mobile initiated operations are supported. Parameter <n> is used to disable/enable the presentation of an
unsolicited result code (USSD response from the network, or network initiated operation)+CUSD:
<m>[,<str>,<dcs>] to the TE. In addition, value <n>=2 is used to cancel an ongoing USSD session.

AT+CUSD Unstructured supplementary service data

www.simcom.com 74 / 483
A76XX Series_AT Command Manual_V1.04

Response
Test Command +CUSD: (range of supported <n>s)
AT+CUSD=?
OK
Response
Read Command +CUSD: <n>
AT+CUSD?
OK
Response
1)
Write Command OK
AT+CUSD=<n>[,<str>[,<dcs> 2)
]] ERROR
3)
+CME ERROR: <err>
Response
Execution Command
Set default value(<n>=0):
AT+CUSD
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<n> 0 disable the result code presentation in the TA


1 enable the result code presentation in the TA
2 cancel session (not applicable to read command response)
<str> String type USSD-string.
<dcs> Cell Broadcast Data Coding Scheme in integer format (default 17).
<m> 0 no further user action required (network initiated USSD-Notify, or
no further information needed after mobile initiated operation)
1 further user action required (network initiated USSD-Request, or
further information needed after mobile initiated operation)
2 USSD terminated by network
4 operation not supported
5 network time out

Examples

AT+CUSD=?
+CUSD: (0-2)

OK
www.simcom.com 75 / 483
A76XX Series_AT Command Manual_V1.04

AT+CUSD?
+CUSD: 1

OK
AT+CUSD=0
OK
AT+CUSD
OK

AT+CSSN Supplementary service notifications

This command refers to supplementary service related network initiated notifications. The set command
enables/disables the presentation of notification result codes from TA to TE.
When <n>=1 and a supplementary service notification is received after a mobile originated call setup,
intermediate result code +CSSI: <code1>[,<index>] is sent to TE before any other MO call setup result
codes presented in the present document. When several different <code1>s are received from the network,
each of them shall have its own +CSSI result code.

When <m>=1 and a supplementary service notification is received during a mobile terminated call setup or
during a call, or when a forward check supplementary service notification is received, unsolicited result
code +CSSU: <code2>[,<index>[,<number>,<type>[,<subaddr>,<satype>]]] is sent to TE. In case of MT
call setup, result code is sent after every +CLIP result code (refer command "Calling line identification
presentation +CLIP")and when several different <code2>s are received from the network, each of them
shall have its own +CSSU result code.

AT+CSSN Supplementary service notifications


Response
1)
+CSSN: (list of supported <n>s),(list of supported <m>s)
Test Command
AT+CSSN=?
OK
2)
ERROR
Response
Read Command +CSSN: <n>,<m>
AT+CSSN?
OK
Response
1)
Write Command
OK
AT+CSSN=<n>[,<m>]
2)
ERROR

www.simcom.com 76 / 483
A76XX Series_AT Command Manual_V1.04

3)
+CME ERROR: <err>
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<n> Parameter sets/shows the +CSSI result code presentation status in


the TA:
0 disable
1 enable
<m> Parameter sets/shows the +CSSU result code presentation status in
the TA:
0 disable
1 enable
<code1> 0 unconditional call forwarding is active
1 some of the conditional call forwarding are active
2 call has been forwarded
3 call is waiting
5 outgoing calls are barred
<index> Refer "Closed user group +CCUG".
<code2> 0 this is a forwarded call (MT call setup)
2 call has been put on hold (during a voice call)
3 call has been retrieved (during a voice call)
5 call on hold has been released (this is not a SS notification)(during
a voice call)
<number> String type phone number of format specified by <type>.
<type> Type of address octet in integer format; default 145 when dialing string
includes international access code character "+", otherwise 129.
<subaddr> String type sub address of format specified by <satype>.
<satype> Type of sub address octet in integer format, default 128.

Examples

AT+CSSN=?
+CSSN: (0-1),(0-1)

OK
AT+CSSN?
+CSSN: 1,1

OK
www.simcom.com 77 / 483
A76XX Series_AT Command Manual_V1.04

AT+CSSN=1,1
OK

AT+CPOL Preferred operator list

This command is used to edit the SIM preferred list of networks.

AT+CPOL Preferred operator list


Response
1)
+CPOL: (range of supported <index>s),(range of supported
Test Command <format>s)
AT+CPOL=?
OK
2)
ERROR
Response
1)
[+CPOL:
<index1>,<format>,<oper1>[<GSM_AcT1>,<GSM_Compact_AcT
1>,<UTRAN_AcT1>,<LTE_AcT1>][<CR><LF><CR><LF>
+CPOL:
Read Command
<index2>,<format>,<oper2>[,<GSM_AcT1>,<GSM_Compact_AcT
AT+CPOL?
1>,<UTRAN_AcT1>,<LTE_AcT1>]
[..]]]

OK
2)
ERROR
Write Command Response
AT+CPOL=<index>[,<format 1)
>[,<oper>][,<GSM_AcT1>,<G OK
SM_Compact_AcT1>,<UTRA 2)
N_AcT1>,<LTE_AcT1>]] ERROR
NOTE: If using USIM card, the 3)
last four parameters must set. +CME ERROR: <err>
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

www.simcom.com 78 / 483
A76XX Series_AT Command Manual_V1.04

Defined Values

<index> Integer type, the order number of operator in the SIM preferred
operator list.
If only input <index>, command will delete the value indicate by
<index>.
<format> 0 long format alphanumeric <oper>
1 short format alphanumeric <oper>
2 numeric <oper>
<operX> String type.
<GSM_AcTn> GSM access technology:
0 access technology not selected
1 access technology selected
<GSM_Compact_AcTn> GSM compact access technology:
0 access technology not selected
1 access technology selected
<UTRA_AcTn> UTRA access technology:
0 access technology not selected
1 access technology selected
<LTE_AcTn> LTE access technology:
0 access technology not selected
1 access technology selected

Examples

AT+CPOL=?
+CPOL: (1-80),(0-2)

OK
AT+CPOL?
+CPOL: 1,2,"46001"

+CPOL: 2,2,"46001"

+CPOL: 3,2,"46001",0,0,0,1

+CPOL: 4,2,"46009",0,0,0,1

+CPOL: 5,2,"46001",0,0,1,0

+CPOL: 6,2,"46009",0,0,1,0

OK
AT+CPOL=1,2,"46001"

www.simcom.com 79 / 483
A76XX Series_AT Command Manual_V1.04

OK

AT+COPN Read operator names

This command is used to return the list of operator names from the ME. Each operator code <numericX>
that has an alphanumeric equivalent <alphaX> in the ME memory shall be returned.

AT+COPN Read operator names


Response
1)
Test Command
OK
AT+COPN=?
2)
ERROR
Response
1)
+COPN: <numeric1>,<alpha1>[<CR><LF><CR><LF>
+COPN: <numeric2>,<alpha2>
[..]]
Execution Command
AT+COPN
OK
2)
ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<numericX> String type, operator in numeric format (see AT+COPS).


<alphaX> String type, operator in long alphanumeric format (see AT+COPS).

Examples

AT+COPN=?
OK
AT+COPN
+COPN: "46000","CMCC"

www.simcom.com 80 / 483
A76XX Series_AT Command Manual_V1.04

+COPN: "46001","UNICOM"
……
OK

AT+CNMP Preferred mode selection

This command is used to select or set the state of the mode preference.

AT+CNMP Preferred mode selection


Response
Test Command +CNMP: (list of supported <mode>s)
AT+CNMP=?
OK
Response
Read Command +CNMP: <mode>
AT+CNMP?
OK
Response
1)
Write Command OK
AT+CNMP=<mode> 2)If <mode> not supported by module, this command will return
ERROR.
ERROR
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<mode> 2 Automatic
13 GSM Only
14 WCDMA Only
38 LTE Only

Examples

AT+CNMP=?
+CNMP: (2,13,14,38)

www.simcom.com 81 / 483
A76XX Series_AT Command Manual_V1.04

OK
AT+CNMP?
+CNMP: 2

OK
AT+CNMP=2
OK

NOTE

1 The response will be returned immediately for Test Command and Read Command. The Max
Response Time for Write Command is 10 seconds.
2 The set value in Write Command will take efficient immediately;

AT+CNBP Preferred band selection

This command is used to select or set the state of the band preference.

AT+CNBP Preferred band selection


Response
Read Command +CNBP: <mode>[,<lte_mode>]
AT+CNBP?
OK
Response
Write Command 1)
AT+CNBP=<mode>[,<lte_mo OK
de>] 2)
ERROR
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<mode> 64bit number, the value is "1" << "<pos>", then or by bit.
<pos> Value:
0xFFFFFFFF7FFFFFFF Any (any value)
7 GSM_DCS_1800

www.simcom.com 82 / 483
A76XX Series_AT Command Manual_V1.04

8 GSM_EGSM_900
9 GSM_PGSM_900
16 GSM_450
17 GSM_480
18 GSM_750
19 GSM_850
20 GSM_RGSM_900
21 GSM_PCS_1900
22 WCDMA_IMT_2000
23 WCDMA_PCS_1900
24 WCDMA_III_1700
25 WCDMA_IV_1700
26 WCDMA_850
27 WCDMA_800
48 WCDMA_VII_2600
49 WCDMA_VIII_900
50 WCDMA_IX_1700
<lte_mode> 64 bit number, the value is "1" << "<lte_pos>", then or by bit.
NOTE: FDD(band1 ~ band32), TDD(band33 ~ band42)
<lte_pos> Value:
0x000007FF3FDF3FFF Any (any value)
0 EUTRAN_BAND1(UL:1920-1980; DL:2110-2170)
1 EUTRAN_BAND2(UL:1850-1910; DL:1930-1990)
2 EUTRAN_BAND3(UL:1710-1785; DL:1805-1880)
3 EUTRAN_BAND4(UL:1710-1755; DL:2110-2155)
4 EUTRAN_BAND5(UL: 824-849; DL: 869-894)
5 EUTRAN_BAND6(UL: 830-840; DL: 875-885)
6 EUTRAN_BAND7(UL:2500-2570; DL:2620-2690)
7 EUTRAN_BAND8(UL: 880-915; DL: 925-960)
8 EUTRAN_BAND9(UL:1749.9-1784.9;
DL:1844.9-1879.9)
9 EUTRAN_BAND10(UL:1710-1770; DL:2110-2170)
10 EUTRAN_BAND11(UL:1427.9-1452.9; DL:1475.9-1500.9)
11 EUTRAN_BAND12(UL:698-716; DL:728-746)
12 EUTRAN_BAND13(UL: 777-787; DL: 746-756)
13 EUTRAN_BAND14(UL: 788-798; DL: 758-768)
16 EUTRAN_BAND17(UL: 704-716; DL: 734-746)
17 EUTRAN_BAND18(UL: 815-830; DL: 860-875)
18 EUTRAN_BAND19(UL: 830-845; DL: 875-890)
19 EUTRAN_BAND20(UL: 832-862; DL: 791-821)
20 EUTRAN_BAND21(UL:1447.9-1462.9; DL: 1495.9-1510.9)
22 EUTRAN_BAND23(UL: 2000-2020; DL: 2180-2200)
23 EUTRAN_BAND24(UL: 1626.5-1660.5; DL: 1525 -1559)
24 EUTRAN_BAND25(UL: 1850-1915; DL: 1930 -1995)
25 EUTRAN_BAND26(UL: 814-849; DL: 859 -894)

www.simcom.com 83 / 483
A76XX Series_AT Command Manual_V1.04

26 EUTRAN_BAND27(UL: 807.5-824; DL: 852 -869)


27 EUTRAN_BAND28(703-748; DL: 758-803)
28 EUTRAN_BAND29(UL:1850-1910 or 1710-1755;
DL:716-728)
29 EUTRAN_BAND30(UL: 2305-2315 ; DL: 2350 - 2360)
32 EUTRAN_BAND33(UL: 1900-1920; DL: 1900-1920)
33 EUTRAN_BAND34(UL: 2010-2025; DL: 2010-2025)
34 EUTRAN_BAND35(UL: 1850-1910; DL: 1850-1910)
35 EUTRAN_BAND36(UL: 1930-1990; DL: 1930-1990)
36 EUTRAN_BAND37(UL: 1910-1930; DL: 1910-1930)
37 EUTRAN_BAND38(UL: 2570-2620; DL: 2570-2620)
38 EUTRAN_BAND39(UL: 1880-1920; DL: 1880-1920)
39 EUTRAN_BAND40(UL: 2300-2400; DL: 2300-2400)
40 EUTRAN_BAND41(UL: 2496-2690; DL: 2496-2690)
41 EUTRAN_BAND42(UL: 3400-3600; DL: 3400-3600)
42 EUTRAN_BAND43(UL: 3600-3800; DL: 3600-3800)

Examples

AT+CNBP?
+CNBP: 0X0002000000400180,0X000001E200000095

OK
AT+CNBP=0X0002000000400180,0X000001E200000095
OK

AT+CPSI Inquiring UE system information

This command is used to return the UE system information.

AT+CPSI Inquiring UE system information


Response
1)
Test Command
OK
AT+CPSI=?
2)
ERROR
Response
1)If camping on a gsm cell:
Read Command
+CPSI: <System Mode>,<Operation
AT+CPSI?
Mode>,<MCC>-<MNC>,<LAC>,<Cell ID>,<Absolute RF Ch
Num>,<RxLev>,<Track LO Adjust>,<C1-C2>

www.simcom.com 84 / 483
A76XX Series_AT Command Manual_V1.04

OK
2)If camping on a wcdma cell:
+CPSI: <System Mode>,<Operation
Mode>,<MCC>-<MNC>,<LAC>,<Cell ID>,<Frequency
Band>,<PSC>,<Freq>,<SSC>,<EC/IO>,<RSCP>,<Qual>,<RxLev>,
<TXPWR>

OK
3)If camping on a lte cell:
+CPSI: <System Mode>,<Operation Mode>[,<MCC>-<MNC>,<TA
C>,<SCellID>,<PCellID>,<Frequency Band>,<earfcn>,<dlbw>,<
ulbw>,<RSRQ>,<RSRP>,<RSSI>,<RSSNR>]

OK
4)If no service:
+CPSI: NO SERVICE, Low Power Mode

OK
5)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<System Mode> System mode, values: "NO SERVICE", "GSM", "WCDMA", "LTE"
<Operation Mode> UE operation mode, values: "Unknown", "Online", "Offline", "Factory
Test Mode", "Reset", "Low Power Mode", "Flight Mode".
<MCC> Mobile Country Code (first part of the PLMN code)
<MNC> Mobile Network Code (second part of the PLMN code)
<LAC> Location Area Code (hexadecimal digits)
<Cell ID> Service-cell Identify.
<Absolute RF Ch Num> AFRCN for service-cell.
<Track LO Adjust> Track LO Adjust
<C1> Coefficient for base station selection
<C2> Coefficient for Cell re-selection
<Frequency Band> Frequency Band of active set
<PSC> Primary synchronization code of active set.
<Freq> Downlink frequency of active set.
<SSC> Secondary synchronization code of active set
<EC/IO> Ec/Io value
www.simcom.com 85 / 483
A76XX Series_AT Command Manual_V1.04

<RSCP> Received Signal Code Power


<Qual> Quality value for base station selection
<RxLev> RX level value for base station selection
<TXPWR> UE TX power in dBm. If no TX, the value is 500.
<Cpid> Cell Parameter ID
<TAC> Tracing Area Code
<PCellID> Physical Cell ID
<earfcn> E-UTRA absolute radio frequency channel number for searching LTE
cells
<dlbw> Transmission bandwidth configuration of the serving cell on the
downlink
<ulbw> Transmission bandwidth configuration of the serving cell on the uplink
<RSRP> Current reference signal received power in -1/10 dBm. Available for
LTE
<RSRQ> Current reference signal receive quality as measured by L1.
<RSSNR> Average reference signal signal-to-noise ratio of the serving cell
<SCellID> String type. cell ID in decimal format for serving cell
<RSSI> Number format. Received signal strength indication.

Examples

AT+CPSI?
+CPSI:
LTE,Online,460-01,0x230A,175499523,318,EUTRAN-BAND3,1650,5,0,21,67,255,19

OK

AT+CNSMOD Show network system mode

This command is used to return the current network system mode.

AT+CNSMOD Show network system mode


Response
Test Command +CNSMOD: (list of supported <n>s)
AT+CNSMOD=?
OK
Response
Read Command 1)
AT+CNSMOD? +CNSMOD: <n>,<stat>

www.simcom.com 86 / 483
A76XX Series_AT Command Manual_V1.04

OK
2)
ERROR
3)
+CME ERROR: <err>
Response
1)
OK
Write Command
2)
AT+CNSMOD=<n>
ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<n> 0 disable auto report the network system mode information


1 auto report the network system mode information, command:
+CNSMOD: <stat>
<stat> 0 no service
1 GSM
2 GPRS
3 EGPRS (EDGE)
4 WCDMA
5 HSDPA only(WCDMA)
6 HSUPA only(WCDMA)
7 HSPA (HSDPA and HSUPA, WCDMA)
8 LTE

Examples

AT+CNSMOD=?
+CNSMOD: (0,1)

OK
AT+CNSMOD?
+CNSMOD: 0,8

OK
AT+CNSMOD=0
OK

www.simcom.com 87 / 483
A76XX Series_AT Command Manual_V1.04

AT+CTZU Automatic time and time zone update

This command is used to enable and disable automatic time and time zone update via NITZ

AT+CTZU Automatic time and time zone update


Response
Test Command +CTZU: (range of supported <on/off>s)
AT+CTZU=?
OK
Response
Read Command +CTZU: <on/off>
AT+CTZU?
OK
Response
1)
Write Command
OK
AT+CTZU=<on/off>
2)
ERROR
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<on/off> Integer type value indicating:


0 Disable automatic time zone update via NITZ.
1 Enable automatic time zone update via NITZ.
NOTE: 1. The value of <on/off> is nonvolatile, and factory value is 0.
2. For automatic time and time zone update is enabled
(+CTZU=1):
If time zone is only received from network and it isn’t equal
to local time zone (AT+CCLK), time zone is updated
automatically, and real time clock is updated based on local
time and the difference between time zone from network
and local time zone (Local time zone must be valid).
If Universal Time and time zone are received from network,
both time zone and real time clock is updated automatically,
and real time clock is based on Universal Time and time
zone from network.

www.simcom.com 88 / 483
A76XX Series_AT Command Manual_V1.04

Examples

AT+CTZU=?
+CTZU: (0-1)

OK
AT+CTZU?
+CTZU: 0

OK
AT+CTZU=0
OK

AT+CTZR Time and time zone reporting

This command is used to enable and disable the time zone change event reporting. If the reporting is
enabled the MT returns the unsolicited result code +CTZV: <tz>[,<time>][,<dst>]whenever the time zone is
changed.

AT+CTZR Time and time zone reporting


Response
Test Command +CTZR: (range of supported <on/off>s)
AT+CTZR=?
OK
Response
Read Command +CTZR: <on/off>
AT+CTZR?
OK
Response
1)
Write Command
OK
AT+CTZR=<on/off>
2)
ERROR
Execution Command Response
AT+CTZR OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values
www.simcom.com 89 / 483
A76XX Series_AT Command Manual_V1.04

<on/off> Integer type value indicating:


0 Disable time zone change event reportin.
1 Enable time zone change event reporting.
+CTZV: Unsolicited result code when time zone received from network isn’t
<tz>[,<time>][,<dst>] equal to local time zone, and if the informations from network don’t
include date and time, time zone will be only reported, and if network
daylight saving time is present, it is also reported. For Examples:
+CTZV: 32 (Only report time zone)
+CTZV: 32,1 (Report time zone and network daylight saving
time)
+CTZV: 32,08/12/09,17:00:00 (Report time and time zone)
+CTZV: 32,08/12/09,17:00:00,1 (Report time, time zone and
daylight saving time)
For more detailed informations about time and time zone, please refer
3GPP TS 24.008.
<tz> Local time zone received from network.
<time> Universal time received from network, and the format is
"yy/MM/dd,hh:mm:ss", where characters indicate year
(two last digits), month, day, hour, minutes and seconds.
<dst> Network daylight saving time, and if it is received from
network, it indicates the value that has been used to
adjust the local time zone. The values as following:
0 No adjustment for Daylight Saving Time.
1 +1 hour adjustment for Daylight Saving Time.
2 +2 hours adjustment for Daylight Saving Time.
NOTE: Herein,<time> is Universal Time or NITZ time, but not local
time.

Examples

AT+CTZR=?
+CTZR: (0-1)

OK
AT+CTZR?
+CTZR: 0

OK
AT+CTZR=0
OK
AT+CTZR
OK

www.simcom.com 90 / 483
A76XX Series_AT Command Manual_V1.04

NOTE

The time zone reporting is not affected by the Automatic Time and Time Zone command AT+CTZU.

www.simcom.com 91 / 483
A76XX Series_AT Command Manual_V1.04

AT Commands for Packet Domain


Overview of AT Commands for Packet Domain

Command Description
AT+CGERG Network registration status
AT+CEREG EPS network registration status
AT+CGATT Packet domain attach or detach
AT+CGACT PDP context activate or deactivate
AT+CGDCONT Define PDP context
AT+CGDSCONT Define Secondary PDP Context
AT+CGTFT Traffic Flow Template
AT+CGQREQ Quality of service profile (requested)
AT+CGEQREQ 3G quality of service profile (requested)
AT+CGQMIN Quality of service profile (minimum acceptable)
AT+CGEQMIN 3G quality of service profile (minimum acceptable)
AT+CGDATA Enter data state
AT+CGPADDR Show PDP address
AT+CGCLASS GPRS mobile station class
AT+CGEREP GPRS event reporting
AT+CGAUTH Set type of authentication for PDP-IP connections of GPRS
AT+CPING Ping destination address

Detailed Description of AT Commands for Packet Domain

AT+CGREG Network registration status

This command controls the presentation of an unsolicited result code "+CGREG: <stat>" when <n>=1 and
there is a change in the MT's GPRS network registration status.

The read command returns the status of result code presentation and an integer <stat> which shows
Whether the network has currently indicated the registration of the MT.
www.simcom.com 92 / 483
A76XX Series_AT Command Manual_V1.04

AT+CGREG Network registration status


Response
Test Command +CGREG: (list of supported <n>s)
AT+CGREG=?
OK
Response
Read Command +CGREG: <n>,<stat>[,<lac>,<ci>]
AT+CGREG?
OK
Write Command Response
AT+CGREG=<n> OK
Response
Execution Command
Set default value:0
AT+CGREG
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<n> 0 disable network registration unsolicited result code


1 enable network registration unsolicited result code +CGREG:
<stat>
2 there is a change in the ME network registration status or a change
of the network cell:
+CGREG: <stat>[,<lac>,<ci>]
<stat> 0 not registered, ME is not currently searching an operator to register
to
1 registered, home network
2 not registered, but ME is currently trying to attach or searching an
operator to register to
3 registration denied
4 unknown
5 registered, roaming
6 registered for "SMS only", home network
<lac> Two byte location area code in hexadecimal format(e.g."00C3" equals
193 in decimal).
<ci> Cell ID in hexadecimal format.
GSM: Maximum is two byte.
WCDMA: Maximum is four byte.

Examples
www.simcom.com 93 / 483
A76XX Series_AT Command Manual_V1.04

AT+CGREG=?
+CGREG: (0-2)

OK
AT+CGREG?
+CGREG: 0,1

OK
AT+CGREG=1
OK
AT+CGREG
OK

AT+CEREG EPS network registration status

The set command controls the presentation of an unsolicited result code +CEREG: <stat> when <n>=1 and
there is a change in the MT's EPS network registration status in E-UTRAN, or unsolicited result code
+CEREG: <stat>[,<tac>,<ci>[,<AcT>]] when <n>=2 and there is a change of the network cell in E-UTRAN;
in this latest case <AcT>,<tac> and <ci> are sent only if available.

The read command returns the status of result code presentation and an integer <stat> which shows
whether the network has currently indicated the registration of the MT. Location information elements
<tac>,<ci> and <AcT>, if available, are returned only when <n>=2 and MT is registered in the network.

AT+CEREG EPS network registration status


Response
1)
+CEREG: (range of supported <n>s)
Test Command
AT+CEREG=?
OK
2)
ERROR
Response
1)
+CEREG: <n>,<stat>[,<tac>,<ci>]
Read Command
AT+CEREG?
OK
2)
ERROR
Write Command Response
AT+CEREG=<n> 1)

www.simcom.com 94 / 483
A76XX Series_AT Command Manual_V1.04

OK
2)
ERROR
3)
+CME ERROR: <err>
Response
1)
Execution Command Set default value(<n>=0):
AT+CEREG OK
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 24.008 [8]

Defined Values

<n> 0 disable network registration unsolicited result code


1 enable network registration unsolicited result code +CEREG:
<stat>
2 enable network registration and location information unsolicited
result code +CEREG: <stat>[,<tac>,<ci>[,<AcT>]]
<stat> 0 not registered, MT is not currently searching an operator to register
to
1 registered, home network
2 not registered, but MT is currently trying to attach or searching an
operator to register to
3 registration denied
4 unknown (e.g. out of E-UTRAN coverage)
5 registered, roaming
6 registered for "SMS only", home network (not applicable)
7 registered for "SMS only", roaming (not applicable)
8 attached for emergency bearer services only (See NOTE 2)
<tac> string type; two byte tracking area code in hexadecimal format (e.g.
"00C3" equals 195 in decimal)
<ci> string type; four byte E-UTRAN cell identify in hexadecimal format
<AcT> A numberic parameter that indicates the access technology of serving
cell
0 GSM (not applicable)
1 GSM Compact (not applicable)
2 UTRAN (not applicable)
3 GSM w/EGPRS (see NOTE 3)(not applicable)
4 UTRAN w/HSDPA (see NOTE 4)(not applicable)
5 UTRAN w/HSUPA (see NOTE 4)(not applicable)

www.simcom.com 95 / 483
A76XX Series_AT Command Manual_V1.04

6 UTRAN w/HSDPA and HSUPA (see NOTE 4)(not applicable)


7 E-UTRAN

Examples

AT+CEREG=?
+CEREG: (0-2)

OK
AT+CEREG?
+CEREG: 0,1

OK
AT+CEREG=1
OK
AT+CEREG
OK

NOTE

If the EPS MT in GERAN/UTRAN/E-UTRAN also supports circuit mode services and/or GPRS
services, the +CREG command and +CREG: result codes and/or the +CGREG command and
+CGREG: result codes apply to the registration status and location information for those services.

AT+CGATT Packet domain attach or detach

The write command is used to attach the MT to, or detach the MT from, the Packet Domain service.
The read command returns the current Packet Domain service state.

AT+CGATT Packet domain attach or detach


Response
1)
+CGATT: (list of supported <state>s)
Test Command
AT+CGATT=?
OK
2)
ERROR
Read Command Response
AT+CGATT? 1)

www.simcom.com 96 / 483
A76XX Series_AT Command Manual_V1.04

+CGATT: <state>

OK
2)
ERROR
Response
1)
OK
Write Command
2)
AT+CGATT=<state>
ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<state> Indicates the state of Packet Domain attachment:


0 detached
1 attached

Examples

AT+CGATT=?
+CGATT: (0-1)

OK
AT+CGATT?
+CGATT: 1

OK
AT+CGATT=1
OK

AT+CGACT PDP context activate or deactivate

The write command is used to activate or deactivate the specified PDP context (s).

AT+CGACT PDP context activate or deactivate


www.simcom.com 97 / 483
A76XX Series_AT Command Manual_V1.04

Response
Test Command +CGACT: (list of supported <state>s)
AT+CGACT=?
OK
Response
+CGACT: [<cid>,<state>[<CR><LF>
Read Command
AT+CGACT? +CGACT: <cid>,<state>[<CR><LF>
[..]]]
OK
Response
1)
OK
Write Command
2)
AT+CGACT=<state>[,<cid>]
ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<state> Indicates the state of PDP context activation:


0 deactivated
1 activated
<cid> A numeric parameter which specifies a particular PDP context
definition (see AT+CGDCONT command).
1…15

Examples

AT+CGACT=?
+CGACT: (0-1)

OK
AT+CGACT?
+CGACT: 1,1

OK
AT+CGACT=1,1
OK

www.simcom.com 98 / 483
A76XX Series_AT Command Manual_V1.04

AT+CGDCONT Define PDP context

The set command specifies PDP context parameter values for a PDP context identified by the (local)context
identification parameter <cid>. The number of PDP contexts that may be in a defined state at the same time
is given by the range returned by the test command. A special form of the write command
(AT+CGDCONT=<cid>)causes the values for context <cid> to become undefined.

AT+CGDCONT Define PDP context


Response
1)
+CGDCONT: (range of supported<cid>s),<PDP_type>,,,(list of
supported <d_comp>s),(list of supported <h_comp>s),(list of
Test Command
<ipv4_ctrl>s),(list of <request_type>s)
AT+CGDCONT=?

OK
2)
ERROR
Response
1)
+CGDCONT:
<cid>,<PDP_type>,<APN>[[,<PDP_addr>],<d_comp>,<h_comp>,
<ipv4_ctrl>,<request_type>,<P-CSCF_discovery>,<IM_CN_Signa
lling_Flag_Ind>]<CR><LF>

Read Command
+CGDCONT:
AT+CGDCONT?
<cid>,<PDP_type>,<APN>[[,<PDP_addr>],<d_comp>,<h_comp>,
<ipv4_ctrl>,<request_type>,<P-CSCF_discovery>,<IM_CN_Signa
lling_Flag_Ind>]

OK
2)
ERROR
Write Command
Response
AT+CGDCONT=<cid>[,<PDP
1)
_type>[,<APN>[,<PDP_addr>
OK
[,<d_comp>[,<h_comp>][,<ip
2)
v4_ctrl>[,<request_type>]]]]]
ERROR
]
Response
Execution Command 1)
AT+CGDCONT OK
2)

www.simcom.com 99 / 483
A76XX Series_AT Command Manual_V1.04

ERROR
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<cid> (PDP Context Identifier)a numeric parameter which specifies a


particular PDP context definition. The parameter is local to the TE-MT
interface and is used in other PDP context-related commands. The
range of permitted values (minimum value=1)is returned by the test
form of the command.
1…15
<PDP_type> (Packet Data Protocol type)a string parameter which specifies the type
of packet data protocol.
IP Internet Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
<APN> (Access Point Name)a string parameter which is a logical name that is
used to select the GGSN or the external packet data network.
<PDP_addr> A string parameter that identifies the MT in the address space
applicable to the PDP. This parameter will be omitted when PDP_type
is PPP type.
Read command will continue to return the null string even if an
address has been allocated during the PDP startup procedure. The
allocated address may be read using command AT+CGPADDR.
<d_comp> A numeric parameter that controls PDP data compression, this value
may depend on platform:
0 off (default if value is omitted)
1 on
2 V.42bis
<h_comp> A numeric parameter that controls PDP header compression, this
value may depend on platform:
0 off (default if value is omitted)
1 RFC1144
<ipv4_ctrl> Parameter that controls how the MT/TA requests to get the IPv4
address information:
0 Address Allocation through NAS Signaling
1 on
<request_type> integer type; indicates the type of PDP context activation request for
the PDP context, see 3GPP TS 24.301 [83] (subclause 6.5.1.2)and
3GPP TS 24.008 [8] (subclause 10.5.6.17). If the initial PDP context is
supported (see subclause 10.1.0)it is not allowed to assign <cid>=0
for emergency bearer services. According to 3GPP TS 24.008 [8]

www.simcom.com 100 / 483


A76XX Series_AT Command Manual_V1.04

(subclause 4.2.4.2.2 and subclause 4.2.5.1.4)and 3GPP TS 24.301


[83] (subclause 5.2.2.3.3 and subclause 5.2.3.2.2), a separate PDP
context must be established for emergency bearer services.
NOTE 4: If the PDP context for emergency bearer services is the only
activated context, only emergency calls are allowed, see 3GPP TS
23.401 [82] subclause 4.3.12.9.
0 PDP context is for new PDP context establishment or for
handover from a non-3GPP access network (how the MT
decides whether the PDP context is for new PDP context
establishment or for handover is implementation specific)
1 PDP context is for emergency bearer services
2 PDP context is for new PDP context establishment
<P-CSCF_discovery> integer type; influences how the MT/TA requests to get the P-CSCF
address, see 3GPP TS 24.229 [89] annex B and annex L.
0 Preference of P-CSCF address discovery not influenced by
+CGDCONT
1 Preference of P-CSCF address discovery through NAS
signalling
2 Preference of P-CSCF address discovery through DHCP
<IM_CN_Signalling_Flag_In integer type; indicates to the network whether the PDP context is for
d> IM CN subsystem-related signalling only or not.
0 UE indicates that the PDP context is not for IM CN
subsystem-related signalling only
1 UE indicates that the PDP context is for IM CN
subsystem-related signalling only

Examples

AT+CGDCONT=?
+CGDCONT: (1-15),"IP",,,(0-2),(0-1),(0-1),(0-2)
+CGDCONT: (1-15),"IPV6",,,(0-2),(0-1),(0-1),(0-2)
+CGDCONT: (1-15),"IPV4V6",,,(0-2),(0-1),(0-1),(0-2)

OK
AT+CGDCONT?
+CGDCONT: 1,"IP",""

OK
AT+CGDCONT=1,"IP","cnnet"
OK
AT+CGDCONT
OK

www.simcom.com 101 / 483


A76XX Series_AT Command Manual_V1.04

AT+CGDSCONT Define Secondary PDP Context

The set command specifies PDP context parameter values for a Secondary PDP context identified by the
(local)context identification parameter,<cid>. The number of PDP contexts that may be in a defined state at
the same time is given by the range returned by the test command. A special form of the set command,
AT+CGDSCONT=<cid> causes the values for context number <cid> to become undefined.

AT+CGDSCONT Define Secondary PDP Context


Response
1)
+CGDSCONT: (range of supported <cid>s),(list of <p_cid>s for
active primary contexts),<PDP_type>,(list of supported
Test Command
<d_comp>s),(list of supported <h_comp>s)
AT+CGDSCONT=?

OK
2)
ERROR
Response
1)
+CGDSCONT: [<cid>,<p_cid>,<d_comp>,<h_comp>
[<CR><LF>+CGDSCONT: <cid>,<p_cid>,<d_comp>,<h_comp>
Read Command
[..]]]
AT+CGDSCONT?

OK
2)
ERROR
Response
Write Command
1)
AT+CGDSCONT=<cid>[,<p_
OK
cid>[,<d_comp>[,<h_comp>]
2)
]]
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<cid> a numeric parameter which specifies a particular PDP context


definition. The parameter is local to the TE-MT interface and is used in
other PDP context-related commands. The range of permitted values
(minimum value=1)is returned by the test form of the command.
NOTE: The <cid>s for network-initiated PDP contexts have values
outside the ranges activated by the +CGACT.
www.simcom.com 102 / 483
A76XX Series_AT Command Manual_V1.04

<p_cid> a numeric parameter which specifies a particular PDP context


definition which has been specified by use of the +CGDCONT
command and activated by the +CGACT. The parameter is local to the
TE-MT interface. The list of permitted values is returned by the test
form of the command.
<PDP_type> (Packet Data Protocol type)a string parameter which specifies the type
of packet data protocol.
IP Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
<d_comp> a numeric parameter that controls PDP data compression (applicable
for SNDCPonly)(refer 3GPP TS 44.065 [61])
0 off
1 on (manufacturer preferred compression)
2 V.42bis
Other values are reserved.
<h_comp> a numeric parameter that controls PDP header compression (refer
3GPP TS 44.065 [61] and 3GPP TS 25.323 [62])
0 off
1 RFC1144
Other values are reserved.

Examples

AT+CGDSCONT=?
+CGDSCONT: (2,3,4,5,6,7,8,9,10,11,12,13,14,15),(1),"IP",(0-2),(0-1)
+CGDSCONT: (2,3,4,5,6,7,8,9,10,11,12,13,14,15),(1),"PPP",(0-2),(0-1)
+CGDSCONT: (2,3,4,5,6,7,8,9,10,11,12,13,14,15),(1),"IPV6",(0-2),(0-1)
+CGDSCONT: (2,3,4,5,6,7,8,9,10,11,12,13,14,15),(1),"IPV4V6",(0-2),(0-1)

OK
AT+CGDSCONT?
+CGDSCONT:

OK
AT+CGDSCONT=4,2
+CME ERROR: operation not supported

AT+CGTFT Traffic Flow Template

This command allows the TE to specify a Packet Filter - PF for a Traffic Flow Template - TFT that is used in
www.simcom.com 103 / 483
A76XX Series_AT Command Manual_V1.04

the GGSN in UMTS/GPRS and Packet GW in EPS for routing of packets onto different QoS flows towards
the TE. The concept is further described in the 3GPP TS 23.060 [47]. A TFT consists of from one and up to
15 Packet Filters, each identified by a unique <packet filter identifier>. A Packet Filter also has an
<evaluation precedence index> that is unique within all TFTs associated with all PDP contexts that are
associated with the same PDP address.

AT+CGTFT Traffic Flow Template


Response
1)
+CGTFT: <PDP_type>,(list of supported <packet filter
identifier>s),(list of supported <evaluation precedence
index>s),(list of supported <source address and subnet
mask>s),(list of supported <protocol number (ipv4)/ next header
(ipv6)>s),(list of supported <destination port range>s),(list of
supported <source port range>s),(list of supported <ipsec security
parameter index (spi)>s),(list of supported <type of service
(tos)(ipv4)and mask / traffic class (ipv6)and mask>s),(list of
supported <flow label (ipv6)>s),(list of supported <direction>s),(list
of supported <local address and subnet mask>s),(range of
supported <QRI>s),(list of supported <traffic_segregation>s)
[<CR><LF>+CGTFT: <PDP_type>,(list of supported <packet filter
Test Command identifier>s),(list of supported <evaluation precedence
AT+CGTFT=? index>s),(list of supported <source address and subnet
mask>s),(list of supported <protocol number (ipv4)/ next header
(ipv6)>s),(list of supported <destination port range>s),(list of
supported <source port range>s),(list of supported <ipsec security
parameter index (spi)>s),(list of supported <type of service
(tos)(ipv4)and mask / traffic class (ipv6)and mask>s),(list of
supported <flow label (ipv6)>s),(list of supported <direction>s),(list
of supported <local address and subnet mask>s),(range of
supported <QRI>s),(list of supported <traffic_segregation>s)

[..]]

OK
2)
ERROR
Response
1)
+CGTFT: [<cid>,<packet filter identifier>,<evaluation precedence
Read Command index>,<source address and subnet mask>,<protocol number
AT+CGTFT? (ipv4)/ next header (ipv6)>,<source port range>,<destination port
range>,<ipsec security parameter index (spi)>,<type of service
(tos)(ipv4)and mask / traffic class (ipv6)and mask>,<direction>

www.simcom.com 104 / 483


A76XX Series_AT Command Manual_V1.04

[<CR><LF>+CGTFT: <cid>,<packet filter identifier>,<evaluation


precedence index>,<source address and subnet
mask>,<protocol number (ipv4)/ next header (ipv6)>,<source
port range>,<destination port range>,<ipsec security parameter
index (spi)>,<type of service (tos)(ipv4)and mask / traffic class
(ipv6)and mask>,<direction>
[..]]]

OK
2)
ERROR
Write Command
AT+CGTFT=<cid>[,[<packet
filter identifier>,<evaluation
precedence index>[,<source
address and subnet
mask>[,<protocol number
Response
(ipv4)/ next header
1)
(ipv6)>[,<destination port
OK
range>[,<source port
2)
range>[,<ipsec security
ERROR
parameter index
(spi)>[,<type of service
(tos)(ipv4)and mask / traffic
class (ipv6)and
mask>[,<flow label
(ipv6)>[,<direction>]]]]]]]]]]
Execution Command Response
AT+CGTFT OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<cid> a numeric parameter which specifies a particular PDP context


definition (see the AT+CGDCONT and AT+CGDSCONT commands).
<PDP_type> (Packet Data Protocol type)a string parameter which specifies the type
of packet data protocol.
IP Internet Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
<packet filter identifier> a numeric parameter, value range from 1 to 15.
<evaluation precedence a numeric parameter. The value range is from 0 to 255.

www.simcom.com 105 / 483


A76XX Series_AT Command Manual_V1.04

index>
<source address and string type The string is given as dot-separated numeric
subnet mask> (0-255)parameters on the form:
"a1.a2.a3.a4.m1.m2.m3.m4" for IPv4 or
"a1.a2.a3.a4.a5.a6.a7.a8.a9.a10.a11.a12.a13.a14.a15.a16.m1.m2.m
3.m4.m5.m6.m7.m8.m9.m10.m11.m12.m13.m14.m15.m16", for IPv6.
NOTE: subnet mask can’t be 0.0.0.0
<protocol number (ipv4)/ a numeric parameter, value range from 0 to 255.
next header (ipv6)>
<destination port range> string type. The string is given as dot-separated numeric
(0-65535)parameters on the form "f.t".
<source port range> string type. The string is given as dot-separated numeric
(0-65535)parameters on the form "f.t".
<ipsec security parameter numeric value in hexadecimal format. The value range is from
index (spi)> 00000000 to FFFFFFFF.
<type of service string type. The string is given as dot-separated numeric
(tos)(ipv4)and mask / traffic (0-255)parameters on the form "t.m".
class (ipv6)and mask>
<flow label (ipv6)> numeric value in hexadecimal format. The value range is from 00000
to FFFFF. Valid for IPv6 only.
<direction> integer type. Specifies the transmission direction in which the packet
filter shall be applied.
0 Pre-Release 7 TFT filter
1 Uplink
2 Downlink
3 Up & Downlink

Examples

AT+CGTFT=?
+CGTFT:
"IP",(1-15),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFFFFFFF),(0-255.0-255),(0-FFF
FF)
+CGTFT:
"IPV6",(1-15),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFFFFFFF),(0-255.0-255),(0-F
FFFF)
+CGTFT:
"IPV4V6",(1-15),(0-255),,(0-255),(0-65535.0-65535),(0-65535.0-65535),(0-FFFFFFFF),(0-255.0-255),(0
-FFFFF)

OK
AT+CGTFT?
+CGTFT:

www.simcom.com 106 / 483


A76XX Series_AT Command Manual_V1.04

OK
AT+CGTFT=1,1,0,"74.125.71.100.255.255.255.255"
OK
AT+CGTFT
OK

NOTE

If a specified PDP context is deactivate, the corresponding Packet Filter TFT need to be specified
again.

AT+CGQREQ Quality of service profile (requested)

This command allows the TE to specify a Quality of Service Profile that is used when the MT sends an
Activate PDP Context Request message to the network. A special form of the set command
(AT+CGQREQ=<cid>)causes the requested profile for context number <cid> to become undefined.

AT+CGQREQ Quality of service profile (requested)


Response
1)
+CGQREQ: <PDP_type>,(list of supported <precedence>s),(list of
supported <delay>s),(list of supported <reliability>s),(list of
Test Command
supported <peak>s),(list of supported <mean>s)
AT+CGQREQ=?

OK
2)
ERROR
Response
1)
+CGQREQ:
[<cid>,<precedence>,<delay>,<reliability>,<peak>,<mean>[<CR>
<LF><LF>
Read Command
+CGQREQ:
AT+CGQREQ?
<cid>,<precedence>,<delay>,<reliability>,<peak>,<mean>[…]]]

OK
2)
ERROR
Write Command Response
AT+CGQREQ=<cid>[,<prece 1)

www.simcom.com 107 / 483


A76XX Series_AT Command Manual_V1.04

dence>[,<delay>[,<reliability OK
>[,<peak>[,<mean>]]]]] 2)
ERROR
Response
1)
Execution Command
OK
AT+CGQREQ
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<cid> A numeric parameter which specifies a particular PDP context


definition (see AT+CGDCONT command). The range is from 1 to 15
<PDP_type> (Packet Data Protocol type)a string parameter which specifies the type
of packet data protocol.
IP Internet Protocol
<precedence> A numeric parameter which specifies the precedence class:
0 network subscribed value
1 high priority
2 normal priority
3 low priority
<delay> A numeric parameter which specifies the delay class:
0 network subscribed value
1 delay class 1
2 delay class 2
3 delay class 3
4 delay class 4
<reliability> A numeric parameter which specifies the reliability class:
0 network subscribed value
1 Non real-time traffic,error-sensitive application that cannot
cope with data loss
2 Non real-time traffic,error-sensitive application that can cope
with infrequent data loss
3 Non real-time traffic,error-sensitive application that can cope
with data loss, GMM/-
SM, and SMS
4 Real-time traffic,error-sensitive application that can cope with
data loss
5 Real-time traffic error non-sensitive application that can cope
with data loss
<peak> A numeric parameter which specifies the peak throughput class:

www.simcom.com 108 / 483


A76XX Series_AT Command Manual_V1.04

0 network subscribed value


1 Up to 1000 (8 kbit/s)
2 Up to 2000 (16 kbit/s)
3 Up to 4000 (32 kbit/s)
4 Up to 8000 (64 kbit/s)
5 Up to 16000 (128 kbit/s)
6 Up to 32000 (256 kbit/s)
7 Up to 64000 (512 kbit/s)
8 Up to 128000 (1024 kbit/s)
9 Up to 256000 (2048 kbit/s)
<mean> A numeric parameter which specifies the mean throughput class:
0 network subscribed value
1 100 (~0.22 bit/s)
2 200 (~0.44 bit/s)
3 500 (~1.11 bit/s)
4 1000 (~2.2 bit/s)
5 2000 (~4.4 bit/s)
6 5000 (~11.1 bit/s)
7 10000 (~22 bit/s)
8 20000 (~44 bit/s)
9 50000 (~111 bit/s)
10 100000 (~0.22 kbit/s)
11 200000 (~0.44 kbit/s)
12 500000 (~1.11 kbit/s)
13 1000000 (~2.2 kbit/s)
14 2000000 (~4.4 kbit/s)
15 5000000 (~11.1 kbit/s)
16 10000000 (~22 kbit/s)
17 20000000 (~44 kbit/s)
18 50000000 (~111 kbit/s)
31 optimization

Examples

AT+CGQREQ=?
+CGQREQ: "IP",(0-3),(0-4),(0-5),(0-9),(0-18,31)

OK
AT+CGQREQ?
+CGQREQ: 1,3,4,3,9,31

OK
AT+CGQREQ=1,3,4,3,9,31
OK

www.simcom.com 109 / 483


A76XX Series_AT Command Manual_V1.04

AT+CGQREQ
OK

AT+CGEQREQ 3G quality of service profile (requested)

The test command returns values supported as a compound value.


The read command returns the current settings for each defined context for which a QOS was explicitly
specified.

The write command allows the TE to specify a Quality of Service Profile for the context identified by the
context identification parameter <cid> which is used when the MT sends an Activate PDP Context Request
message to the network.

A special form of the write command, AT+CGEQREQ=<cid> causes the requested profile for context
number <cid> to become undefined.

AT+CGEQREQ 3G quality of service profile (requested)


Response
1)
+CGEQREQ: <PDP_type>,(list of supported <Traffic class>s),(list
of supported <Maximum bitrate UL>s),(list of supported <Maximum
bitrate DL>s),(list of supported <Guaranteed bitrate UL>s,(list of
supported <Guaranteed bitrate DL>s),(list of supported <Deliv ery
order>s),(list of supported <Maximum SDU size>s),(list of supported
Test Command <SDU error ratio>s),(list of supported <Residual bit error
AT+CGEQREQ=? Ratio>s),(list of supported <Delivery of erroneous SDUs>s),(list of
Supported <Transfer delay>s),(list of supported <Traffic handling
priority>s),(list of supported <Source statistics descriptor>s),(list
of supported <Signaling indication flag>s)

OK
2)
ERROR
Response
1)
+CGEQREQ: [<cid>,<Traffic class>,<Maximum bitrate
UL>,<Maximum bitrate DL>,<Guaranteed bitrate
Read Command
UL>,<Guaranteed bitrate DL>,<Delivery order>,<Maximum SDU
AT+CGEQREQ?
size>,<SDU error ratio>,<Residual bit error ratio>,<Delivery of
erroneous SDUs>,<Transfer Delay>,<Traffic handling
priority>,<Source statistics descriptor>,<Signaling indication
flag>][<CR><LF><LF>

www.simcom.com 110 / 483


A76XX Series_AT Command Manual_V1.04

+CGEQREQ: <cid>,<Traffic class>,<Maximum bitrate


UL>,<Maximum bitrate DL>,<Guaranteed bitrate
UL>,<Guaranteed bitrate DL>,<Delivery order>,<Maximum SDU
size>,<SDU error ratio>,<Residual bit error ratio>,<Delivery of
erroneous SDUs>,<Transfer Delay>,<Traffic handling
priority>,<Source statistics descriptor>,<Signaling indication
flag>[…]]

OK
2)
ERROR
Write Command
AT+CGEQREQ=<cid>[,<Traff
ic class>[,<Maximum bitrate
UL>[,<Maximum bitrate
DL>[,<Guaranteed bitrate
Response
UL>[,<Guaranteed bitrate
1)
DL>[,<Delivery
OK
order>[,<Maximum SDU
2)
size>[,<SDU error
ERROR
ratio>[,<Residual bit error
3)
ratio>[,<Delivery of
+CME ERROR: <err>
erroneous SDUs>[,<Transfer
delay>[,<Traffic handling
priority>[,<Source statistics
descriptor>[,<Signaling
indication flag>]]]]]]]]]]]]]]
Response
1)
Execution Command
OK
AT+CGEQREQ
2)
ERROR
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<cid> Parameter specifies a particular PDP context definition. The


parameter is also used in other PDP context-related commands. The
range is from 1 to 15
<Traffic class> 0 conversational
1 streaming
2 interactive

www.simcom.com 111 / 483


A76XX Series_AT Command Manual_V1.04

3 background
4 subscribed value
<Maximum bitrate UL> This parameter indicates the maximum number of kbits/s delivered to
UMTS(up-link traffic)at a SAP. As an Examples a bitrate of 32kbit/s
would be specified as 32(e.g. AT+CGEQREQ=…,32,…).
The range is from 0 to 256000. When the parameter is between 64
and 568, it should be an integer multiple of 8; between 568 and 8640
(except 8640), it should be an integer multiple of 64; between 8641
and 16000, it should be an integer multiple of 100; between 16000 and
128000, it should be an integer multiple of 1000; between 128000 and
256000, it should be an integer multiple of 2000. The default value is
0. If the parameter is set to '0' the subscribed value will be requested.
<Maximum bitrate DL> This parameter indicates the maximum number of kbits/s delivered to
UMTS(down-link traffic)at a SAP.As an Examples a bitrate of 32kbit/s
would be specified as 32(e.g. AT+CGEQREQ=…,32,…).
The range is from 0 to 256000. When the parameter is between 64
and 568, it should be an integer multiple of 8; between 568 and 8640
(except 8640), it should be an integer multiple of 64; between 8641
and 16000, it should be an integer multiple of 100; between 16000 and
128000, it should be an integer multiple of 1000; between 128000 and
256000, it should be an integer multiple of 2000. The default value is
0. If the parameter is set to '0' the subscribed value will be
requested.3600-3800)
<Guaranteed bitrate UL> This parameter indicates the guaranteed number of kbit/s delivered to
UMTS(up-link traffic)at a SAP(provided that there is data to deliver).As
an Examples a bitrate of 32kbit/s would be specified as
32(e.g.AT+CGEQREQ=…,32,…).
The range is from 0 to 256000. When the parameter is between 64
and 568, it should be an integer multiple of 8; between 568 and
8640(except 8640), it should be an integer multiple of 64; between
8641 and 16000, it should be an integer multiple of 100; between
16000 and 128000, it should be an integer multiple of 1000; between
128000 and 256000, it should be an integer multiple of 2000. The
default value is 0. If the parameter is set to '0' the subscribed value will
be requested.
<Guaranteed bitrate DL> This parameter indicates the guaranteed number of kbit/s delivered to
UMTS(down-link traffic)at a SAP(provided that there is data to
deliver).As an Examples a bitrate of 32kbit/s would be specified as
32(e.g.AT+CGEQREQ=…,32,…).
The range is from 0 to 256000. When the parameter is between 64
and 568, it should be an integer multiple of 8; between 568 and
8640(except 8640), it should be an integer multiple of 64; between
8641 and 16000, it should be an integer multiple of 100; between
16000 and 128000, it should be an integer multiple of 1000; between
128000 and 256000, it should be an integer multiple of 2000. The

www.simcom.com 112 / 483


A76XX Series_AT Command Manual_V1.04

default value is 0. If the parameter is set to '0' the subscribed value will
be requested.
<Delivery order> This parameter indicates whether the UMTS bearer shall provide
in-sequence SDU delivery or not.
0 no
1 yes
2 subscribed value
<Maximum SDU size> This parameter indicates the maximum allowed SDU size in octets.
The range is 0, 10 to 1500, 1510, 1520. When the parameter is
between 10 and 1510, it should be an integer multiple of 10. The
default value is 0. If the parameter is set to '0' the subscribed value will
be requested.
<SDU error ratio> This parameter indicates the target value for the fraction of SDUs lost
or detected as erroneous. SDU error ratio is defined only for
conforming traffic. As an Examples a target SDU error ratio of 5*10-3
would be specified as "5E3"(e.g. AT+CGEQREQ=.,"5E3",…).
"0E0" subscribed value
"1E2"
"7E3"
"1E3"
"1E4"
"1E5"
"1E6"
"1E1"
<Residual bit error ratio> This parameter indicates the target value for the undetected bit error
ratio in the delivered SDUs. If no error detection is requested,
Residual bit error ratio indicates the bit error ratio in the delivered
SDUs. As an Examples a target residual bit error ratio of 5*10-3 would
be specified as "5E3"(e.g.
AT+CGEQREQ=…,"5E3",.).
"0E0" subscribed value
"5E2"
"1E2"
"5E3"
"4E3"
"1E3"
"1E4"
"1E5"
"1E6"
"6E8"
<Delivery of erroneous This parameter indicates whether SDUs detected as erroneous shall
SDUs> be delivered or not.
0 no
1 yes
2 no detect

www.simcom.com 113 / 483


A76XX Series_AT Command Manual_V1.04

3 subscribed value
<Transfer delay> This parameter indicates the targeted time between request to transfer
an SDU at one SAP to its delivery at the other SAP, in milliseconds.
The range is 0 to 950. When the parameter is between 10 and 150, it
should be an integer multiple of 10. When the parameter is between
150 and 950, it should be an integer multiple of 50. The default value
is 0. If the parameter is set to '0' the subscribed value will be
requested.
<Traffic handling priority> This parameter specifies the relative importance for handling of all
SDUs belonging to the UMTS
Bearer compared to the SDUs of the other bearers.
The range is from 0 to 3. The default value is 0. If the parameter is set
to '0' the subscribed value will be requested.
<Source statistics This parameter indicates profile parameter that Source statistics
descriptor> descriptor for requested UMTS QoS The range is from 0 to 1. The
default value is 0. If the parameter is set to '0' the subscribed value will
be requested.
<Signaling indication flag> This parameter indicates Signaling flag.
The range is from 0 to 1 The default value is 0. If the parameter is set
to '0' the subscribed value will be requested.
<PDP_type> (Packet Data Protocol type)a string parameter which specifies the type
of packet data protocol.
IP Internet Protocol

Examples

AT+CGEQREQ=?
+CGEQREQ:
"IP",(0-4),(0-256000),(0-256000),(0-256000),(0-256000),(0-2),(0-1520),("0E0","1E1","1E2","7E3","1E
3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E4","1E5","1E6","6E8"),(0-3),(0-95
0),(0-3),(0-1),(0-1)

OK
AT+CGEQREQ?
+CGEQREQ: 1,4,0,0,0,0,2,0,"0E0","0E0",3,0,0,0,0

OK
AT+CGEQREQ=1,4,0,0,0,0,2,0,"0E0","0E0",3,0,0,0,0
OK
AT+CGEQREQ
OK

www.simcom.com 114 / 483


A76XX Series_AT Command Manual_V1.04

AT+CGQMIN Quality of service profile (minimum acceptable)

This command allows the TE to specify a minimum acceptable profile which is checked by the MT against
the negotiated profile returned in the Activate PDP Context Accept message. A special form of the set
command, AT+CGQMIN=<cid> causes the minimum acceptable profile for context number <cid> to
become undefined.

AT+CGQMIN Quality of service profile (minimum acceptable)


Response
1)
+CGQMIN: <PDP_type>,(list of supported <precedence>s),(list of
supported <delay>s),(list of supported <reliability>s),(list of
supported <peak>s),(list of supported <mean>s)[<CR><LF>
Test Command +CGQMIN: <PDP_type>,(list of supported <precedence>s),(list of
AT+CGQMIN=? supported <delay>s),(list of supported <reliability>s),(list of
supported <peak>s),(list of supported <mean>s)[…]]

OK
2)
ERROR
Response
1)
+CGQMIN:
[<cid>,<precedence>,<delay>,<reliability>,<peak>,<mean>[<CR>
<LF><LF>
Read Command
+CGQMIN:
AT+CGQMIN?
<cid>,<precedence>,<delay>,<reliability>,<peak>,<mean>[…]]]

OK
2)
ERROR
Response
Write Command
1)
AT+CGQMIN=<cid>[,<preced
OK
ence>[,<delay>[,<reliability>
2)
[,<peak>[,<mean>]]]]]
ERROR
Response
1)
Execution Command
OK
AT+CGQMIN
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007
www.simcom.com 115 / 483
A76XX Series_AT Command Manual_V1.04

Defined Values

<cid> A numeric parameter which specifies a particular PDP context


definition (see AT+CGDCONT command). The range is from 1 to 15
<PDP_type> (Packet Data Protocol type)a string parameter which specifies the type
of packet data protocol.
IP Internet Protocol
<precedence> A numeric parameter which specifies the precedence class:
0 network subscribed value
1 high priority
2 normal priority
3 low priority
<delay> A numeric parameter which specifies the delay class:
0 network subscribed value
1 delay class 1
2 delay class 2
3 delay class 3
4 delay class 4
<reliability> A numeric parameter which specifies the reliability class:
0 network subscribed value
1 Non real-time traffic, error-sensitive application that cannot
cope with data loss
2 Non real-time traffic, error-sensitive application that can cope
with infrequent data loss
3 Non real-time traffic, error-sensitive application that can cope
with data loss, GMM/-
SM, and SMS
4 Real-time traffic, error-sensitive application that can cope with
data loss
5 Real-time traffic error non-sensitive application that can cope
with data loss
<peak> A numeric parameter which specifies the peak throughput class:
0 network subscribed value
1 Up to 1000 (8 kbit/s)
2 Up to 2000 (16 kbit/s)
3 Up to 4000 (32 kbit/s)
4 Up to 8000 (64 kbit/s)
5 Up to 16000 (128 kbit/s)
6 Up to 32000 (256 kbit/s)
7 Up to 64000 (512 kbit/s)
8 Up to 128000 (1024 kbit/s)
9 Up to 256000 (2048 kbit/s)
<mean> A numeric parameter which specifies the mean throughput class:

www.simcom.com 116 / 483


A76XX Series_AT Command Manual_V1.04

0 network subscribed value


1 100 (~0.22 bit/s)
2 200 (~0.44 bit/s)
3 500 (~1.11 bit/s)
4 1000 (~2.2 bit/s)
5 2000 (~4.4 bit/s)
6 5000 (~11.1 bit/s)
7 10000 (~22 bit/s)
8 20000 (~44 bit/s)
9 50000 (~111 bit/s)
10 100000 (~0.22 kbit/s)
11 200000 (~0.44 kbit/s)
12 500000 (~1.11 kbit/s)
13 1000000 (~2.2 kbit/s)
14 2000000 (~4.4 kbit/s)
15 5000000 (~11.1 kbit/s)
16 10000000 (~22 kbit/s)
17 20000000 (~44 kbit/s)
18 50000000 (~111 kbit/s)
31 optimization

Examples

AT+CGQMIN=?
+CGQMIN: "IP",(0-3),(0-4),(0-5),(0-9),(0-18,31)

OK
AT+CGQMIN?
+CGQMIN: 1,3,4,5,1,1

OK
AT+CGQMIN=1,3,4,5,1,1
OK
AT+CGQMIN
OK

AT+CGEQMIN 3G quality of service profile (minimum acceptable)

The test command returns values supported as a compound value.

The read command returns the current settings for each defined context for which a QOS was explicitly
specified.
www.simcom.com 117 / 483
A76XX Series_AT Command Manual_V1.04

The write command allow the TE to specify a Quallity of Service Profile for the context identified by the
context identification parameter<cid> which is checked by the MT against the negotiated profile returned in
the Activate/Modify PDP Context Accept message.

A special form of the write command, AT+CGEQMIN=<cid> causes the requested for context number <cid>
to become undefined.

AT+CGEQMIN 3G quality of service profile (minimum acceptable)


Response
1)
+CGEQMIN: <PDP_type>,(list of supported <Traffic class>s),(list of
supported <Maximum bitrate UL>s),(list of supported <Maximum
bitrate DL>s),(list of supported <Guaranteed bitrate UL>s,(list of
supported<Guaranteed bitrate DL>s),(list of supported <Delivery
order>s),(list of supported <Maximum SDU size>s),(list of supported
Test Command <SDU error ratio>s),(list of supported <Residual bit error
AT+CGEQMIN=? Ratio>s),(list of supported <Delivery of erroneous SDUs>s),(list of
Supported <Transfer delay>s),(list of supported <Traffic
handlingpriority>s),(list of supported <Source statistics
descriptor>s),(list of supported <Signaling indication flag>s)

OK
2)
ERROR
Response
1)
+CGEQMIN: [<cid>,<Traffic class>,<Maximum bitrate
UL>,<Maximum bitrate DL>,<Guaranteed bitrate
UL>,<Guaranteed bitrateDL>,<Delivery order>,<Maximum SDU
size>,<SDU error ratio>,<Residual bit error ratio>,<Delivery of
erroneous SDUs>,<Transfer Delay>,<Traffic handling
priority>,<Source statistics descriptor>,<Signaling indication
flag>][<CR><LF><LF>+CGEQMIN: <cid>,<Traffic
Read Command
class>,<Maximum bitrate UL>,<Maximum bitrate
AT+CGEQMIN?
DL>,<Guaranteed bitrate UL>,<Guaranteed bitrateDL>,<Delivery
order>,<Maximum SDU size>,<SDU error ratio>,<Residual bit
error ratio>,<Delivery of erroneous SDUs>,<Transfer
Delay>,<Traffic handling priority>,<Source statistics
descriptor>,<Signaling indication flag>[…]]

OK
2)
ERROR
Write Command Response

www.simcom.com 118 / 483


A76XX Series_AT Command Manual_V1.04

AT+CGEQMIN=<cid>[,<Traffi 1)
c class>[,<Maximum bitrate OK
UL>[,<Maximum bitrate 2)
DL>[,<Guaranteed bitrate ERROR
UL>[,<Guaranteed 3)
bitrateDL>[,<Delivery +CME ERROR: <err>
order>[,<Maximum SDU
size>[,<SDU error
ratio>[,<Residual biterror
ratio>[,<Delivery of
erroneous SDUs>[,<Transfer
delay>[,<Traffic
handlingpriority>[,<Source
statistics
descriptor>[,<Signaling
indication flag>]]]]]]]]]]]]]]
Response
1)
Execution Command
OK
AT+CGEQMIN
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<cid> Parameter specifies a particular PDP context definition. The


parameter is also used in other PDP context-related commands. The
range is from 1 to 15.
<Traffic class> 0 conversational
1 streaming
2 interactive
3 background
4 subscribed value
<Maximum bitrate UL> This parameter indicates the maximum number of kbits/s delivered to
UMTS(up-link traffic)at a SAP.As an Examples a bitrate of 32kbit/s
would be specified as 32(e.g. AT+CGEQMIN=…,32,…).
The range is from 0 to 256000. When the parameter is between
64 and 568, it should be an integer multiple of 8; between 568 and
8640(except 8640), it should be an integer multiple of 64; between
8641 and 16000, it should be an integer multiple of 100; between
16000 and 128000, it should be an integer multiple of 1000; between
128000 and 256000, it should be an integer multiple of 2000. The

www.simcom.com 119 / 483


A76XX Series_AT Command Manual_V1.04

default value is 0. If the parameter is set to '0' the subscribed value will
be requested.
<Maximum bitrate DL> This parameter indicates the maximum number of kbits/s delivered to
UMTS(down-link traffic)at a SAP.As an Examples a bitrate of 32kbit/s
would be specified as 32(e.g. AT+CGEQMIN=…,32,…).
The range is from 0 to 256000. When the parameter is between 64
and 568, it should be an integer multiple of 8; between 568 and
8640(except 8640), it should be an integer multiple of 64; between
8640 and 16000, it should be an integer multiple of 100; between
16000 and 128000, it should be an integer multiple of 1000; between
128000 and 256000, it should be an integer multiple of 2000. The
default value is 0. If the parameter is set to '0' the subscribed value will
be requested.
<Guaranteed bitrate UL> This parameter indicates the guaranteed number of kbit/s delivered to
UMTS(up-link traffic)at a SAP(provided that there is data to deliver).As
an Examples a bitrate of 32kbit/s would be specified as
32(e.g.AT+CGEQMIN=…,32,…).
The range is from 0 to 256000. When the parameter is between 64
and 568, it should be an integer multiple of 8; between 568 and
8640(except 8640), it should be an integer multiple of 64; between
8640 and 16000, it should be an integer multiple of 100; between
16000 and 128000, it should be an integer multiple of 1000; between
128000 and 256000, it should be an integer multiple of 2000. The
default value is 0. If the parameter is set to '0' the subscribed value will
be requested.
<Guaranteed bitrate DL> This parameter indicates the guaranteed number of kbit/s delivered to
UMTS(down-link traffic)at a SAP(provided that there is data to
deliver).As an Examples a bitrate of 32kbit/s would be specified as
32(e.g.AT+CGEQMIN=…,32,…).
The range is from 0 to 256000. When the parameter is between 64
and 568, it should be an integer multiple of 8; between 568 and
8640(except 8640), it should be an integer multiple of 64; between
8641 and 16000, it should be an integer multiple of 100; between
16000 and 128000, it should be an integer multiple of 1000; between
128000 and 256000, it should be an integer multiple of 2000. The
default value is 0. If the parameter is set to '0' the subscribed value will
be requested.
<Delivery order> This parameter indicates whether the UMTS bearer shall provide
in-sequence SDU delivery or not.
0 no
1 yes
2 subscribed value
<Maximum SDU size> This parameter indicates the maximum allowed SDU size inoctets.
The range is 0, 10 to 1500, 1510, 1520. When the parameter is
between 10 and 1510, it should be an integer multiple of 10. The

www.simcom.com 120 / 483


A76XX Series_AT Command Manual_V1.04

default value is 0. If the parameter is set to '0' the subscribed value will
be requested.
<SDU error ratio> This parameter indicates the target value for the fraction of SDUs lost
or detected as erroneous. SDU error ratio is defined only for
conforming traffic.As an Examples a target SDU error ratio of 5*10-3
would be specified as "5E3"(e.g.AT+CGEQMIN=.,"5E3",…).
"0E0" subscribed value
"1E2"
"7E3"
"1E3"
"1E4"
"1E5"
"1E6"
"1E1"
<Residual bit error ratio> This parameter indicates the target value for the undetected bit error
ratio in the delivered SDUs. If no error detection is requested,
Residual bit error ratio indicates the bit error ratio in the delivered
SDUs. As an Examples a target residual bit error ratio of 5*10-3 would
be specified as "5E3"(e.g.
AT+CGEQMIN=…,"5E3",.).
"0E0" subscribed value
"5E2"
"1E2"
"5E3"
"4E3"
"1E3"
"1E4"
"1E5"
"1E6"
"6E8"
<Delivery of erroneous This parameter indicates whether SDUs detected as erroneous shall
SDUs> be delivered or not.
0 no
1 yes
2 no detect
3 subscribed value
<Transfer delay> This parameter indicates the targeted time between request to transfer
an SDU at one SAP to its delivery at the other SAP, in milliseconds.
The range is from 0 to 950, and the parameter is an integer of 10. The
default value is 0. If the parameter is set to '0' the subscribed value will
be requested.
<Traffic handling priority> This parameter specifies the relative importance for handling of all
SDUs belonging to the UMTS.
Bearer compared to the SDUs of the other bearers.
The range is 0 to 3. The default value is 0. If the parameter is set to '0'

www.simcom.com 121 / 483


A76XX Series_AT Command Manual_V1.04

the subscribed value will be requested.


<Source statistics This parameter indicates profile parameter that Source statistics
descriptor> descriptor for requested UMTS QoS
The range is from 0 to 1. The default value is 0. If the parameter is set
to '0' the subscribed value will be requested.
<Signaling indication flag> This parameter indicates Signaling flag.
The range is from 0 to 1 The default value is 0. If the parameter is set
to '0' the subscribed value will be requested.
<PDP_type> (Packet Data Protocol type)a string parameter which specifies the type
of packet data protocol.
IP Internet Protocol

Examples

AT+CGEQMIN=?
+CGEQMIN:
"IP",(0-4),(0-256000),(0-256000),(0-256000),(0-256000),(0-2),(0-1520),("0E0","1E1","1E2","7E3","1E
3","1E4","1E5","1E6"),("0E0","5E2","1E2","5E3","4E3","1E3","1E4","1E5","1E6","6E8"),(0-3),(0-95
0),(0-3),(0-1),(0-1)

OK
AT+CGEQMIN?
+CGEQMIN: 1,4,0,0,0,0,2,0,"0E0","0E0",3,0,0,0,0

OK
AT+CGEQMIN=1,4,0,0,0,0,2,0,"0E0","0E0",3,0,0,0,0
OK
AT+CGEQMIN
OK

AT+CGDATA Enter data state

The command causes the MT to perform whatever actions are necessary to establish communication
between the TE and the network using one or more Packet Domain PDP types. This may include
performing a PS attach and one or more PDP context activations.

AT+CGDATA Enter data state


Response
Test Command 1)
AT+CGDATA=? +CGDATA: (list of supported <L2P>s)

www.simcom.com 122 / 483


A76XX Series_AT Command Manual_V1.04

OK
2)
ERROR
Response
1)
CONNECT [<text>]
2)
Write Command NO CARRIER
AT+CGDATA=[<L2P>,[<cid>] 3)
] OK
4)
ERROR
5)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<L2P> A string parameter that indicates the layer 2 protocol to be used


between the TE and MT.
NULL
<text> CONNECT result code string; the string formats please refer ATX
command.
<cid> A numeric parameter which specifies a particular PDP context
definition (see AT+CGDCONT command).
1…15

Examples

AT+CGDATA=?
+CGDATA: ("")

OK
AT+CGDATA="",1
CONNECT

AT+CGPADDR Show PDP address

www.simcom.com 123 / 483


A76XX Series_AT Command Manual_V1.04

The write command returns a list of PDP addresses for the specified context identifiers.

AT+CGPADDR Show PDP address


Response
1)
[+CGPADDR: (list of defined <cid>s)]
Test Command
AT+CGPADDR=?
OK
2)
ERROR
Response
1)
[+CGPADDR: <cid>,<PDP_addr>[<CR><LF>
+CGPADDR: <cid>,<PDP_addr>[..]]]

OK
Write Command 2)
AT+CGPADDR=<cid>[,<cid>[ SIM card supports IPV4V6 type and the PDP_type of the command
,…]] "at+cgdcont" defined is ipv4v6:
[+CGPADDR: <cid>,<PDP_addr_IPV4>,<PDP_addr_IPV6>]
+CGPADDR: <cid>,<PDP_addr_IPV4>,<PDP_addr_IPV6>[..]

OK
3)
ERROR
Response
1)
[+CGPADDR: <cid>,<PDP_addr>]
+CGPADDR: <cid>,<PDP_addr>[..]

OK
2)
SIM card supports IPV4V6 type and the PDP_type of the command
Execution Command
"at+cgdcont" defined is ipv4v6:
AT+CGPADDR
[+CGPADDR: <cid>,<PDP_addr_IPV4>,<PDP_addr_IPV6>]
+CGPADDR: <cid>,<PDP_addr_IPV4>,<PDP_addr_IPV6>[..]

OK
3)
ERROR
4)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

www.simcom.com 124 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<cid> A numeric parameter which specifies a particular PDP context


definition (see AT+CGDCONT command). If no <cid> is specified, the
addresses for all defined contexts are returned.
1…15
<PDP_addr> A string that identifies the MT in the address space applicable to the
PDP. The address may be static or dynamic. For a static address, it
will be the one set by the AT+CGDCONT command when the context
was defined. For a dynamic address it will be the one assigned during
the last PDP context activation that used the context definition referred
to by <cid>. <PDP_addr> is omitted if none is available.
<PDP_addr_IPV4> A string parameter that identifies the MT in the address space
applicable to the PDP.
<PDP_addr_IPV6> A string parameter that identifies the MT in the address space
applicable to the PDP when the sim_card supports ipv6. The pdp type
must be set to "ipv6" or "ipv4v6" by the AT+CGDCONT command.

Examples

AT+CGPADDR=?
+CGPADDR: (1)

OK
AT+CGPADDR=1
+CGPADDR: 1,10.83.214.110

OK
AT+CGPADDR
+CGPADDR: 1,10.83.214.110

OK

AT+CGCLASS GPRS mobile station class

This command is used to set the MT to operate according to the specified GPRS mobile class.

AT+CGCLASS GPRS mobile station class


Test Command Response

www.simcom.com 125 / 483


A76XX Series_AT Command Manual_V1.04

AT+CGCLASS=? 1)
+CGCLASS: (list of supported <class>s)

OK
2)
ERROR
Response
1)
+CGCLASS: <class>
Read Command
AT+CGCLASS?
OK
2)
ERROR
Response
1)
OK
Write Command
2)
AT+CGCLASS=<class>
ERROR
3)
+CME ERROR: <err>
Response
1)
Execution Command
OK
AT+CGCLASS
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<class> A string parameter which indicates the GPRS mobile class (in
descending order of functionality)
A class A (highest)

Examples

AT+CGCLASS=?
+CGCLASS: ("A")

OK
AT+CGCLASS?
+CGCLASS: "A"

www.simcom.com 126 / 483


A76XX Series_AT Command Manual_V1.04

OK
AT+CGCLASS="A"
OK
AT+CGCLASS
OK

AT+CGEREP GPRS event reporting

The write command enables or disables sending of unsolicited result codes, "+CGEV" from MT to TE in the
case of certain events occurring in the Packet Domain MT or the network. <mode> controls the processing
of unsolicited result codes specified within this command. <bfr> controls the effect on buffered codes when
<mode> 1 or 2 is entered. If a setting is not supported by the MT, ERROR or +CME ERROR: is returned.

Read command returns the current <mode> and buffer settings.

Test command returns the modes and buffer settings supported by the MT as compound values.

AT+CGEREP GPRS event reporting


Response
1)
+CGEREP: (list of supported <mode>s),(list of supported <bfr>s)
Test Command
AT+CGEREP=?
OK
2)
ERROR
Response
1)
+CGEREP: <mode>,<bfr>
Read Command
AT+CGEREP?
OK
2)
ERROR
Response
1)
Write Command OK
AT+CGEREP=<mode>[,<bfr> 2)
] ERROR
3)
+CME ERROR: <err>
Execution Command Response
AT+CGEREP 1)Set default value (<mode>=2,<bfr>=0):

www.simcom.com 127 / 483


A76XX Series_AT Command Manual_V1.04

OK
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<mode> 0 buffer unsolicited result codes in the MT; if MT result code buffer is
full, the oldest ones can be discarded. No codes are forwarded to the
TE.
1 discard unsolicited result codes when MT-TE link is reserved (e.g.
in on-line data mode); otherwise forward them directly to the TE.
2 buffer unsolicited result codes in the MT when MT-TE link is
reserved (e.g. in on-line data mode)and flush them to the TE when
MT-TE link becomes available; otherwise forward them directly to the
TE.
<bfr> 0 MT buffer of unsolicited result codes defined within this command
is cleared when <mode> 1 or 2 is entered.
1 MT buffer of unsolicited result codes defined within this command
is flushed to the TE when <mode> 1 or 2 is entered (OK response
shall be given before flushing the codes).

The events are valid for GPRS/UMTS and LTE unless explicitly mentioned.
For network attachment, the following unsolicited result codes and the corresponding events are defined:

+CGEV: NW DETACH The network has forced a PS detach. This implies that all active
contexts have been deactivated. These are not reported separately.
+CGEV: ME DETACH The mobile termination has forced a PS detach. This implies that all
active contexts have been deactivated. These are not reported
separately.

For MT class, the following unsolicited result codes and the corresponding events are defined:

+CGEV: NW CLASS <class> The network has forced a change of MT class. The highest available
class is reported (see +CGCLASS). The format of the parameter
<class> is found in command +CGCLASS.
+CGEV: ME CLASS <class> The mobile termination has forced a change of MT class. The highest
available class is reported (see +CGCLASS). The format of the
parameter <class> is found in command +CGCLASS.

www.simcom.com 128 / 483


A76XX Series_AT Command Manual_V1.04

For PDP context activation, the following unsolicited result codes and the corresponding events are defined:

+CGEV: NW PDN ACT The network has activated a context. The context represents a
<cid>[,<WLAN_Offload>] Primary PDP context in GSM/UMTS. The <cid> for this context is
provided to the TE. The format of the parameter <cid> is found in
command +CGDCONT.

<WLAN_Offload>: integer type. An integer that indicates whether


traffic can be offloaded using the specified PDN connection via a
WLAN or not. This refers to bit 1 (E-UTRAN offload acceptability
value)and bit 2 (UTRAN offload acceptability value)in the WLAN
offload acceptability IE as specified in 3GPP TS 24.008 [8] subclause
10.5.6.20.
0 offloading the traffic of the PDN connection via a WLAN when in
S1 mode or when in Iu mode is not acceptable.
1 offloading the traffic of the PDN connection via a WLAN when in
S1 mode is acceptable, but not acceptable in Iu mode.
2 offloading the traffic of the PDN connection via a WLAN when in
Iu mode is acceptable, but not acceptable in S1 mode.
3 offloading the traffic of the PDN connection via a WLAN when in
S1 mode or when in Iu mode is acceptable.

NOTE

This event is not applicable for EPS.

+CGEV: ME PDN ACT The mobile termination has activated a context. The context
<cid>[,<reason>[,<cid_other represents a PDN connection in LTE or a Primary PDP context in
>]][,<WLAN_Offload>] GSM/UMTS. The <cid> for this context is provided to the TE. This
event is sent either in result of explicit context activation request
(+CGACT), or in result of implicit context activation request associated
to attach request (+CGATT=1). The format of the parameters <cid>
and <cid_other> are found in command +CGDCONT. The format of
the parameter <WLAN_Offload> is defined above.

<reason>: integer type; indicates the reason why the context


activation request for PDP type IPv4v6 was not granted. This
parameter is only included if the requested PDP type associated with
<cid> is IPv4v6, and the PDP type assigned by the network for <cid>
is either IPv4 or IPv6.
0 IPv4 only allowed

www.simcom.com 129 / 483


A76XX Series_AT Command Manual_V1.04

1 IPv6 only allowed


2 single address bearers only allowed.
3 single address bearers only allowed and MT initiated
context activation for a second address type
bearer was not successful.
4 CI_PS_PDP_INVALID_REASON
<cid_other>: integer type; indicates the context identifier allocated by
MT for an MT initiated context of a second address type. MT shall only
include this parameter if <reason> parameter indicates single address
bearers only allowed, and MT supports MT initiated context activation
of a second address type without additional commands from TE, and
MT has activated the PDN connection or PDP context associated with
<cid_other>.

NOTE

For legacy TEs supporting MT initiated context activation without TE requests, there is also a
subsequent event +CGEV: ME PDN ACT <cid_other> returned to TE.

+CGEV: NW ACT The network has activated a context. The <cid> for this context is
<p_cid>,<cid>,<event_type> provided to the TE in addition to the associated primary <p_cid>. The
[,<WLAN_Offload>] format of the parameters <p_cid> and <cid> are found in command
+CGDSCONT. The format of the parameter <WLAN_Offload> is
defined above.

<event_type>: integer type; indicates whether this is an informational


event or whether the TE has to acknowledge it.
0 Informational event
1 Information request: Acknowledgement required. The
acknowledgement can be accept or reject, see +CGANS.
+CGEV: ME ACT The network has responded to an ME initiated context activation. The
<p_cid>,<cid>,<event_type> <cid> for this context is provided to the TE in addition to the
[,<WLAN_Offload>] associated primary <p_cid>. The format of the parameters <p_cid>
and <cid> are found in command +CGDSCONT. The format of the
parameters <event_type> and <WLAN_Offload> are defined above.

For PDP context deactivation, the following unsolicited result codes and the corresponding events are
defined:

www.simcom.com 130 / 483


A76XX Series_AT Command Manual_V1.04

+CGEV: NW DEACT The network has forced a context deactivation. The <cid> that was
<PDP_type>,<PDP_addr>[,< used to activate the context is provided if known to the MT. The format
cid>] of the parameters <PDP_type>,<PDP_addr> and <cid> are found in
command +CGDCONT.
+CGEV: ME DEACT The mobile termination has forced a context deactivation. The <cid>
<PDP_type>,<PDP_addr>[,< that was used to activate the context is provided if known to the MT.
cid>] The format of the parameters <PDP_type>,<PDP_addr> and <cid>
are found in command +CGDCONT.
+CGEV: NW PDN DEACT The network has deactivated a context. The context represents a PDN
<cid>[,<WLAN_Offload>] connection in LTE or a Primary PDP context in GSM/UMTS. The
associated <cid> for this context is provided to the TE. The format of
the parameter <cid> is found in command +CGDCONT. The format of
the parameter <WLAN_Offload> is defined above.

NOTE

Occurrence of this event replaces usage of the event +CGEV: NW DEACT


<PDP_type>,<PDP_addr>[,<cid>].

+CGEV: ME PDN DEACT The mobile termination has deactivated a context. The context
<cid> represents a PDN connection in LTE or a Primary PDP context in
GSM/UMTS. The <cid> for this context is provided to the TE. The
format of the parameter <cid> is found in command +CGDCONT.

NOTE

Occurrence of this event replaces usage of the event +CGEV: ME DEACT


<PDP_type>,<PDP_addr>[,<cid>].

+CGEV: NW DEACT The network has deactivated a context. The <cid> for this context is
<p_cid>,<cid>,<event_type> provided to the TE in addition to the associated primary <p_cid>. The
[,<WLAN_Offload>] format of the parameters <p_cid> and <cid> are found in command
+CGDSCONT. The format of the parameters <event_type> and
<WLAN_Offload> are defined above.

NOTE

Occurrence of this event replaces usage of the event +CGEV: NW DEACT

www.simcom.com 131 / 483


A76XX Series_AT Command Manual_V1.04

<PDP_type>,<PDP_addr>[,<cid>].

+CGEV: ME DEACT The network has responded to an ME initiated context deactivation


<p_cid>,<cid>,<event_type> request. The associated <cid> is provided to the TE in addition to the
associated primary <p_cid>. The format of the parameters <p_cid>
and <cid> are found in command +CGDSCONT. The format of the
parameter <event_type> is defined above.

NOTE

Occurrence of this event replaces usage of the event +CGEV: ME DEACT


<PDP_type>,<PDP_addr>[,<cid>].

For PDP context modification, the following unsolicited result codes and the corresponding events are
defined:

+CGEV: NW MODIFY The network has modified a context. The associated <cid> is provided
<cid>,<change_reason>,<ev to the TE in addition to the <change_reason> and <event_type>. The
ent_type>[,<WLAN_Offload format of the parameter <cid> is found in command +CGDCONT or
>] +CGDSCONT. The format of the parameters
<change_reason>,<event_type>, and <WLAN_Offload> are defined
above.

<change_reason>: integer type; a bitmap that indicates what kind of


change occurred. The <change_reason> value is determined by
summing all the applicable bits. For Examples if both the values of
QoS changed (Bit 2)and <WLAN_Offload> changed (Bit 3)have
changed, then the <change_reason> value is 6.

NOTE

The WLAN offload value will change when bit 1 or bit 2 or both of the indicators in the WLAN offload
acceptability IE change, see the parameter <WLAN_Offload> defined above.
Bit 1 TFT changed
Bit 2 Qos changed
Bit 3 WLAN Offload changed

www.simcom.com 132 / 483


A76XX Series_AT Command Manual_V1.04

+CGEV: ME MODIFY The mobile termination has modified a context. The associated <cid>
<cid>,<change_reason>,<ev is provided to the TE in addition to the <change_reason> and
ent_type>[,<WLAN_Offload <event_type>. The format of the parameter <cid> is found in
>] command +CGDCONT or +CGDSCONT. The format of the
parameters <change_reason>,<event_type> and <WLAN_Offload>
are defined above.

For other PDP context handling, the following unsolicited result codes and the corresponding events are
defined:

+CGEV: REJECT A network request for context activation occurred when the MT was
<PDP_type>,<PDP_addr> unable to report it to the TE with a +CRING unsolicited result code and
was automatically rejected. The format of the parameters <PDP_type>
and <PDP_addr> are found in command +CGDCONT.

NOTE

This event is not applicable for EPS.

+CGEV: NW REACT The network has requested a context reactivation. The <cid> that was
<PDP_type>,<PDP_addr>[,< used to reactivate the context is provided if known to the MT. The
cid>] format of the parameters <PDP_type>,<PDP_addr> and <cid> are
found in command +CGDCONT.

NOTE

This event is not applicable for EPS.

Examples

AT+CGEREP=?
+CGEREP: (0-2),(0-1)

OK
AT+CGEREP?
+CGEREP: 2,0

OK

www.simcom.com 133 / 483


A76XX Series_AT Command Manual_V1.04

AT+CGEREP=2,0
OK
AT+CGEREP
OK

AT+CGAUTH Set type of authentication for PDP-IP connections of GPRS

This command is used to set type of authentication for PDP-IP connections of GPRS.

AT+CGAUTH Set type of authentication for PDP-IP connections of GPRS


Response
1)
+CGAUTH: (range of supported <cid>s),(list of supported
<auth_type> s),50,50
Test Command
AT+CGAUTH=? OK
2)
ERROR
3)
+CME ERROR: <err>
Response
1)
+CGAUTH: [<cid>,<auth_type>[,<user>,<passwd>]]

Read Command
AT+CGAUTH? OK
2)
ERROR
3)
+CME ERROR: <err>
Response
1)
Write Command OK
AT+CGAUTH=<cid>[,<auth_t 2)
ype>[,<passwd>[,<user>]]] ERROR
3)
+CME ERROR: <err>
Response
1)
Execution Command
OK
AT+CGAUTH
2)
ERROR

www.simcom.com 134 / 483


A76XX Series_AT Command Manual_V1.04

3)
+CME ERROR: <err>
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<cid> Parameter specifies a particular PDP context definition. This is also


used in other PDP context-related commands.
1…15
<auth_type> Indicate the type of authentication to be used for the specified context.
If CHAP is selected another parameter <passwd> needs to be
specified. If PAP is selected two additional parameters <passwd> and
<user> need to specified.
0 none
1 PAP
2 CHAP
<passwd> Parameter specifies the password used for authentication.
<user> Parameter specifies the user name used for authentication.

Examples

AT+CGAUTH=?
+CGAUTH: (1-15),(0-2),50,50

OK
AT+CGAUTH?
+CGAUTH: 1,0

OK
AT+CGAUTH=1,0
OK
AT+CGAUTH
OK

NOTE
 Currently 1601 has auto-save function

www.simcom.com 135 / 483


A76XX Series_AT Command Manual_V1.04

AT+CPING Ping destination address

This command is used to ping destination address.

AT+CPING Ping destination address


Response
1)
+CPING: IP address,(list of supported
<dest_addr_type>s),(1-5),(4-188),(1000-10000),(10000-100000),(1
Test Command
6-255)
AT+CPING=?

OK
2)
ERROR
Response
1)
OK

If ping’s result_type=1
+CPING:
Write Command <result_type>,<resolved_ip_addr>,<data_packet_size>,<rtt>,<TT
AT+CPING=<dest_addr>,<de L>
st_addr_type>[,<num_pings
>[,<data_packet_size>[,<inte If ping’s result_type=2
rval_time>[,<wait_time>[,<T +CPING: <result_type>
TL>]]]]]
If ping’s result_type=3>
+CPING:
<result_type>,<num_pkts_sent>,<num_pkts_recvd>,<num_pkts
_lost>,<min_rtt>,<max_rtt>,<avg_rtt>
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<dest_addr> The destination is to be pinged; it can be an IP address or a domain


name.
<dest_addr_type> Integer type. Address family type of the destination address
1 IPv4.
2 IPv6(reserved)

www.simcom.com 136 / 483


A76XX Series_AT Command Manual_V1.04

<num_pings> Integer type. The num_pings specifies the number of times the ping
request (1-5)is to be sent. The default value is 4.
<data_packet_size> Integer type. Data byte size of the ping packet (4-188). The default
value is 64 bytes.
<interval_time> Integer type. Interval between each ping. Value is specified in
milliseconds (1000ms-10000ms). The default value is 2000ms.
<wait_time> Integer type. Wait time for ping response. An ping response received
after the timeout shall not be processed. Value specified in
milliseconds (10000ms-100000ms). The default value is 10000ms.
<TTL> Integer type. TTL(Time-To-Live)value for the IP packet over which the
ping(ICMP ECHO Request message)is sent (16-255), the default
value is 255.
<result_type> 1 Ping success
2 Ping time out
3 Ping result
<num_pkts_sent> Indicates the number of ping requests that were sent out.
<num_pkts_recvd> Indicates the number of ping responses that were received.
<num_pkts_lost> Indicates the number of ping requests for which no response was
received.
<min_rtt> Indicates the minimum Round Trip Time(RTT).
<max_rtt> Indicates the maximum RTT.
<avg_rtt> Indicates the average RTT.
<resolved_ip_addr> Indicates the resolved ip address.
<rtt> Round Trip Time.

Examples

AT+CPING=?
+CPING: IP
address,(1,2),(1-5),(4-188),(1000-10000),(10000-100000),(16-255)

OK
AT+CPING="www.baidu.com",1,4,64,1000,10000,255
OK

+CPING: 2

+CPING: 2

+CPING: 2

+CPING: 2

+CPING: 3,4,0,4,0,0,0
www.simcom.com 137 / 483
A76XX Series_AT Command Manual_V1.04

AT Commands for SIM Card


Overview of AT Commands for SIM Card

Command Description
AT+CICCID Read ICCID from SIM card
AT+CPIN Enter PIN
AT+CLCK Facility lock
AT+CPWD Change password
AT+CIMI Request international mobile subscriber identity
AT+CSIM Generic SIM access
AT+CRSM Restricted SIM access
AT+SPIC Times remain to input SIM PIN/PUK
AT+CSPN Get service provider name from SIM
AT+UIMHOTSWAPON Set UIM hotswap function on
AT+UIMHOTSWAPLEVEL Set UIM card detection level
AT+SWITCHSIM Switch master SIM
AT+DUALSIM Set dual-sim mode
AT+BINDSIM Bind ATP to SIM1 or SIM2

Detailed Description of AT Commands for SIM Card

AT+CICCID Read ICCID from SIM card

This command is used to Read the ICCID from SIM card.

AT+CICCID Read ICCID from SIM card


Test Command Response
AT+CICCID=? OK
Execution Command Response
AT+CICCID 1)

www.simcom.com 138 / 483


A76XX Series_AT Command Manual_V1.04

+ICCID: <ICCID>

OK
2)
ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference Vendor

Defined Values

<ICCID> Integrate circuit card identity, a standard ICCID is a 20-digit serial


number of the SIM card,it presents the publish state, network code,
publish area, publish date, publish manufacture and press serial
number of the SIM card.

Examples

AT+CICCID
+ICCID: 89860318760238610932

OK
AT+CICCID=?
OK

AT+CPIN Enter PIN

This command is used to send the ME a password which is necessary before it can be operated (SIM PIN,
SIM PUK, PH-SIM PIN, etc.). If the PIN is to be entered twice, the TA shall automatically repeat the PIN. If
no PIN request is pending, no action is taken towards MT and an error message, +CME ERROR, is
returned to TE.

If the PIN required is SIM PUK or SIM PUK2, the second pin is required. This second pin,<newpin>, is used
to replace the old pin in the SIM.

AT+CPIN Enter PIN


Test Command Response
AT+CPIN=? OK

www.simcom.com 139 / 483


A76XX Series_AT Command Manual_V1.04

Response
1)
+CPIN: <code>

Read Command
OK
AT+CPIN?
2)
ERROR
3)
+CME ERROR: <err>
Response
1)
OK
Write Command
2)
AT+CPIN=<pin>[,<newpin>]
ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode AUTO_SAVE_REBOOT
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<pin> String type values.


<newpin> String type values.
<code> Values reserved by the present document:
READY ME is not pending for any password
SIM PIN ME is waiting SIM PIN to be given
SIM PUK ME is waiting SIM PUK to be given
PH-SIM PIN ME is waiting phone-to-SIM card password to be given
SIM PIN2 ME is waiting SIM PIN2 to be given
SIM PUK2 ME is waiting SIM PUK2 to be given
PH-NET PIN ME is waiting network personalization password to be
given

Examples

AT+CPIN=?
OK
AT+CPIN?
+CPIN: READY

OK
AT+CPIN=1234

www.simcom.com 140 / 483


A76XX Series_AT Command Manual_V1.04

OK

AT+CLCK Facility lock

This command is used to lock, unlock or interrogate a ME or a network facility <fac>. Password is normally
needed to do such actions. When querying the status of a network service (<mode>=2)the response line for
'not active' case (<status>=0)should be returned only if service is not active for any <class>.

AT+CLCK Facility lock


Response
Test Command +CLCK: (list of supported <fac>s)
AT+CLCK=?
OK
Response
1)
OK
2)
When <mode>=2 and command successful:
+CLCK: <status>[,<class1>[
Write Command
+CLCK: <status>,<class2>
AT+CLCK=<fac>,<mode>
[..]]
[,<passwd>[,<class>]]

OK
3)
ERROR
4)
+CME ERROR: <err>
Parameter Saving Mode AUTO_SAVE_REBOOT
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<fac> "SC" lock SIM card or USIM card


"AO" Barr All Outgoing Calls
"OI" Barr Outgoing International Calls
"OX" Barr Outgoing International Calls except to Home Country
"AI" Barr All Incoming Calls
"IR" Barr Incoming Calls when roaming outside the home country
"AB" All Barring services (only for <mode>=0)
"AG" All outGoing barring services (only for <mode>=0)

www.simcom.com 141 / 483


A76XX Series_AT Command Manual_V1.04

"AC" All inComing barring services (only for <mode>=0)


"FD" SIM fixed dialing memory feature
"PN" Network Personalization
"PU" network subset Personalization
"PP" service Provider Personalization
"PC" Corporate Personalization
<mode> 0 unlock
1 lock
2 query status
<status> 0 not active
1 active
<passwd> Password.
string type; shall be the same as password specified for the facility
from the ME user interface or with command Change Password
+CPWD
<class> It is a sum of integers each representing a class of information (default
7):
1 voice (telephony)
2 data (refers to all bearer services)
4 fax (facsimile services)
8 short message service
16 data circuit sync
32 data circuit sync
64 dedicated packet access
128 dedicated PAD access
255 The value 255 covers all classes

Examples

AT+CLCK="SC",2
+CLCK: 0

OK
AT+CLCK=?
+CLCK:
("SC","AO","OI","OX","AI","IR","AB","AG","AC","FD","PN","PU","PP","PC")

OK

AT+CPWD Change password

Write command sets a new password for the facility lock function defined by command Facility Lock
www.simcom.com 142 / 483
A76XX Series_AT Command Manual_V1.04

AT+CLCK.

Test command returns a list of pairs which present the available facilities and the maximum length of their
password.

AT+CPWD Change password


Response
1)
+CPWD: (list of supported (<fac>,<pwdlength>)s)

Test Command
OK
AT+CPWD=?
2)
ERROR
3)
+CME ERROR: <err>
Response
1)
Write Command OK
AT+CPWD=<fac>,<oldpwd>, 2)
<newpwd> ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode AUTO_SAVE_REBOOT
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<fac> Refer Facility Lock +CLCK for other values:


"SC" SIM or USIM PIN1
"P2" SIM or USIM PIN2
"AB" All Barring services
"AC" All inComing barring services (only for <mode>=0)
"AG" All outGoing barring services (only for <mode>=0)
"AI" Barr All Incoming Calls
"AO" Barr All Outgoing Calls
"IR" Barr Incoming Calls when roaming outside the home country
"OI" Barr Outgoing International Calls
"OX" Barr Outgoing International Calls except to Home Country
<oldpwd> String type, it shall be the same as password specified for the facility
from the ME user interface or with command Change Password
AT+CPWD.
<newpwd> String type, it is the new password; maximum length of password can
be determined with <pwdlength>.
www.simcom.com 143 / 483
A76XX Series_AT Command Manual_V1.04

<pwdlength> Integer type, max length of password.

Examples

AT+CPWD=?
+CPWD:
("AB",4),("AC",4),("AG",4),("AI",4),("AO",4),("IR",4),("OI",4),("OX",4),(
"SC",8),("P2",8)

OK
AT+CPWD="SC","1234","4321"
OK

AT+CIMI Request international mobile subscriber identity

Execution command causes the TA to return <IMSI>, which is intended to permit the TE to identify the
individual SIM card which is attached to MT.

AT+CIMI Request international mobile subscriber identity


Response
1)
Test Command
OK
AT+CIMI=?
2)
ERROR
Response
1)
<IMSI>
Execution Command
AT+CIMI
OK
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<IMSI> International Mobile Subscriber Identity (string, without double


quotes).

www.simcom.com 144 / 483


A76XX Series_AT Command Manual_V1.04

Examples

AT+CIMI=?
OK
AT+CIMI
460010222028133

OK

NOTE

If USIM card contains two apps, like China Telecom 4G card, one RUIM/CSIM app, and another USIM
app; so there are two IMSI in it; AT+CIMI will return the RUIM/CSIM IMSI.

AT+CSIM Generic SIM access

This command is used to control the SIM card directly.

Compared to restricted SIM access command AT+CRSM, AT+CSIM allows the ME to take more control
over the SIM interface.

For SIM–ME interface please refer 3GPP TS 11.11.

AT+CSIM Generic SIM access


Test Command Response
AT+CSIM=? OK
Response
1)
+CSIM: <length>,<response>
Write Command
AT+CSIM=<length>,<comma OK
nd> 2)
ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

www.simcom.com 145 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<length> Interger type; length of characters that are sent to TE in <command>


or <response>
<command> Command passed from MT to SIM card.
<response> Response to the command passed from SIM card to MT.

Examples

AT+CSIM=?
OK
AT+CSIM=10,"A0F2000016"
+CSIM:4,"6E00"

OK

NOTE

The SIM Application Toolkit functionality is not supported by AT+CSIM. Therefore the following SIM
commands can not be used: TERMINAL PROFILE, ENVELOPE, FETCH and TEMINAL RESPONSE.

AT+CRSM Restricted SIM access

By using AT+CRSM instead of Generic SIM Access AT+CSIM, TE application has easier but more limited
access to the SIM database.

Write command transmits to the MT the SIM <command> and its required parameters. MT handles
internally all SIM-MT interface locking and file selection routines. As response to the command, MT sends
the actual SIM information parameters and response data. MT error result code +CME ERROR may be
returned when the command cannot be passed to the SIM, but failure in the execution of the command in
the SIM is reported in <sw1> and <sw2> parameters.

AT+CRSM Restricted SIM access


Test Command Response
AT+CRSM=? OK
Write Command Response
AT+CRSM=<command>[,<fil 1)
eID>[,<p1>,<p2>,<p3>[,<data +CRSM: <sw1>,<sw2>[,<response>]

www.simcom.com 146 / 483


A76XX Series_AT Command Manual_V1.04

>]]]
OK
2)
ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time -
Reference 3GPP TS 27.007

Defined Values

<command> Command passed on by the MT to the SIM:


176 READ BINARY
178 READ RECORD
192 GET RESPONSE
214 UPDATE BINARY
220 UPDATE RECORD
242 STATUS
203 RETRIEVE DATA
219 SET DATA
<fileID> Identifier for an elementary data file on SIM, if used by <command>.
The following list the fileID hex value, user needs to convet them to
decimal.
EFs under MF
0x2FE2 ICCID
0x2F05 Extended Language Preferences
0x2F00 EF DIR
0x2F06 Access Rule Reference EFs under USIM ADF
0x6F05 Language Indication
0x6F07 IMSI
0x6F08 Ciphering and Integrity keys
0x6F09 C and I keys for pkt switched domain
0x6F60 User controlled PLMN selector w/Acc Tech
0x6F30 User controlled PLMN selector
0x6F31 HPLMN search period
0x6F37 ACM maximum value
0x6F38 USIM Service table
0x6F39 Accumulated Call meter
0x6F3E Group Identifier Level
0x6F3F Group Identifier Level 2
0x6F46 Service Provider Name
0x6F41 Price Per Unit and Currency table
0x6F45 Cell Bcast Msg identifier selection

www.simcom.com 147 / 483


A76XX Series_AT Command Manual_V1.04

0x6F78 Access control class


0x6F7B Forbidden PLMNs
0x6F7E Location information
0x6FAD Administrative data
0x6F48 Cell Bcast msg id for data download
0x6FB7 Emergency call codes
0x6F50 Cell bcast msg id range selection
0x6F73 Packet switched location information
0x6F3B Fixed dialling numbers
0x6F3C Short messages
0x6F40 MSISDN
0x6F42 SMS parameters
0x6F43 SMS Status
0x6F49 Service dialling numbers
0x6F4B Extension 2
0x6F4C Extension 3
0x6F47 SMS reports
0x6F80 Incoming call information
0x6F81 Outgoing call information
0x6F82 Incoming call timer
0x6F83 Outgoing call timer
0x6F4E Extension 5
0x6F4F Capability Config Parameters 2
0x6FB5 Enh Multi Level Precedence and Pri
0x6FB6 Automatic answer for eMLPP service
0x6FC2 Group identity
0x6FC3 Key for hidden phonebook entries
0x6F4D Barred dialling numbers
0x6F55 Extension 4
0x6F58 Comparison Method information
0x6F56 Enabled services table
0x6F57 Access Point Name Control List
0x6F2C De-personalization Control Keys
0x6F32 Co-operative network list
0x6F5B Hyperframe number
0x6F5C Maximum value of Hyperframe number
0x6F61 OPLMN selector with access tech
0x6F5D OPLMN selector
0x6F62 HPLMN selector with access technology
0x6F06 Access Rule reference
0x6F65 RPLMN last used access tech
0x6FC4 Network Parameters
0x6F11 CPHS: Voice Mail Waiting Indicator
0x6F12 CPHS: Service String Table
0x6F13 CPHS: Call Forwarding Flag
0x6F14 CPHS: Operator Name String
www.simcom.com 148 / 483
A76XX Series_AT Command Manual_V1.04

0x6F15 CPHS: Customer Service Profile


0x6F16 CPHS: CPHS Information
0x6F17 CPHS: Mailbox Number
0x6FC5 PLMN Network Name
0x6FC6 Operator PLMN List
0x6F9F Dynamic Flags Status
0x6F92 Dynamic2 Flag Setting
0x6F98 Customer Service Profile Line2
0x6F9B EF PARAMS - Welcome Message
0x4F30 Phone book reference file
0x4F22 Phone book synchronization center
0x4F23 Change counter
0x4F24 Previous Unique Identifier
0x4F20 GSM ciphering key Kc
0x4F52 GPRS ciphering key
0x4F63 CPBCCH information
0x4F64 Investigation scan
0x4F40 MExE Service table
0x4F41 Operator Root Public Key
0x4F42 Administrator Root Public Key
0x4F43 Third party Root public key
0x6FC7 Mail Box Dialing Number
0x6FC8 Extension 6
0x6FC9 Mailbox Identifier
0x6FCA Message Waiting Indication Status
0x6FCD Service Provider Display Information
0x6FD2 UIM_USIM_SPT_TABLE
0x6FD9 Equivalent HPLMN
0x6FCB Call Forwarding Indicator Status
0x6FD6 GBA Bootstrapping parameters
0x6FDA GBA NAF List
0x6FD7 MBMS Service Key
0x6FD8 MBMS User Key
0x6FCE MMS Notification
0x6FD0 MMS Issuer connectivity parameters
0x6FD1 MMS User Preferences
0x6FD2 MMS User connectivity parameters
0x6FCF Extension 8
0x5031 Object Directory File
0x5032 Token Information File
0x5033 Unused space Information File EFs under Telecom DF
0x6F3A Abbreviated Dialing Numbers
0x6F3B Fixed dialling numbers
0x6F3C Short messages
0x6F3D Capability Configuration Parameters
0x6F4F Extended CCP
www.simcom.com 149 / 483
A76XX Series_AT Command Manual_V1.04

0x6F40 MSISDN
0x6F42 SMS parameters
0x6F43 SMS Status
0x6F44 Last number dialled
0x6F49 Service Dialling numbers
0x6F4A Extension 1
0x6F4B Extension 2
0x6F4C Extension 3
0x6F4D Barred Dialing Numbers
0x6F4E Extension 4
0x6F47 SMS reports
0x6F58 Comparison Method Information
0x6F54 Setup Menu elements
0x6F06 Access Rule reference
0x4F20 Image
0x4F30 Phone book reference file
0x4F22 Phone book synchronization center
0x4F23 Change counter
0x4F24 Previous Unique Identifier
<p1> <p2> <p3> Integer type; parameters to be passed on by the Module to the SIM.
<data> Information which shall be written to the SIM (hexadecimal character
format, refer AT+CSCS).
<sw1> <sw2> Status information from the SIM about the execution of the actual
command. It is returned in both cases, on successful or failed
execution of the command.
<response> Response data in case of a successful completion of the previously
issued command.
"STATUS" and "GET RESPONSE" commands return data, which
gives information about the currently selected elementary data field.
This information includes the type of file and its size.
After "READ BINARY" or "READ RECORD" commands the requested
data will be returned.
<response> is empty after "UPDATE BINARY" or "UPDATE
RECORD" commands.

Examples

AT+CRSM=?
OK
AT+CRSM=242
+CRSM:
144,0,"000000003F00040000FFBB01020000"

OK

www.simcom.com 150 / 483


A76XX Series_AT Command Manual_V1.04

AT+SPIC Times remain to input SIM PIN/PUK

This command is used to inquire times remain to input SIM PIN/PUK.

AT+SPIC Times remain to input SIM PIN/PUK


Test Command Response
AT+SPIC=? OK
Response
Execution Command +SPIC: <pin1>,<puk1>,<pin2>,<puk2>
AT+SPIC
OK
Parameter Saving Mode NO_SAVE
Max Response Time -
Reference Vendor

Defined Values

<pin1> Times remain to input PIN1 code.


<puk1> Times remain to input PUK1 code.
<pin2> Times remain to input PIN2 code.
<puk2> Times remain to input PUK2 code.

Examples

AT+SPIC=?
OK
AT+SPIC
+SPIC: 3,10,0,10

OK

AT+CSPN Get service provider name from SIM

This command is used to get service provider name from SIM card.

www.simcom.com 151 / 483


A76XX Series_AT Command Manual_V1.04

AT+CSPN Get service provider name from SIM


Response
1)
Test Command
OK
AT+CSPN=?
2)
ERROR
Response
1)
+CSPN: <spn>,<display mode>

OK
Read Command
2)
AT+CSPN?
OK
3)
ERROR
4)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time -
Reference Vendor

Defined Values

<spn> String type; service provider name on SIM


<display mode> 0 doesn’t display PLMN. Already registered on PLMN.
1 display PLMN

Examples

AT+CSPN=?
OK
AT+CSPN?
+CSPN: "China Telecom",1

OK

AT+UIMHOTSWAPON Set UIM Hotswap Function On

AT+UIMHOTSWAPON Set UIM hotswap function on

www.simcom.com 152 / 483


A76XX Series_AT Command Manual_V1.04

Response
1)
+UIMHOTSWAPON: (0-1)
Test Command
AT+UIMHOTSWAPON=?
OK
2)
ERROR
Response
1)
+UIMHOTSWAPON: <onoff>
Read Command
AT+UIMHOTSWAPON?
OK
2)
ERROR
Response
Write Command 1)
AT+UIMHOTSWAPON=<onof OK
f> 2)
ERROR
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference Vendor

Defined Values

<onoff> 0 The UIM hotswap function is disabled


1 The UIM hotswap function is enabled

Examples

AT+UIMHOTSWAPON=?
+UIMHOTSWAPON: (0-1)

OK
AT+UIMHOTSWAPON?
+UIMHOTSWAPON: 0

OK
AT+UIMHOTSWAPON=1
OK

NOTE

www.simcom.com 153 / 483


A76XX Series_AT Command Manual_V1.04

Modules should be reset to take effect.

AT+UIMHOTSWAPLEVEL Set UIM Card Detection Level

AT+UIMHOTSWAPLEVEL Set UIM Card Detection Level


Response
1)
+UIMHOTSWAPLEVEL: (0-1)
Test Command
AT+UIMHOTSWAPLEVEL=?
OK
2)
ERROR
Response
1)
+UIMHOTSWAPLEVEL: <level>
Read Command
AT+UIMHOTSWAPLEVEL?
OK
2)
ERROR
Response
Write Command 1)
AT+UIMHOTSWAPLEVEL=<l OK
evel> 2)
ERROR
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference Vendor

Defined Values

<level> 0 ACTIVE LOW


1 ACTIVE HIGH

Examples

AT+UIMHOTSWAPLEVEL=?
+UIMHOTSWAPLEVEL: (0-1)

www.simcom.com 154 / 483


A76XX Series_AT Command Manual_V1.04

OK
AT+UIMHOTSWAPLEVEL?
+UIMHOTSWAPLEVEL: 0

OK
AT+UIMHOTSWAPLEVEL=1
OK

AT+SWITCHSIM Switch master SIM

This command to set mater SIM.Only applied for dual-sim project.


AT+SWITCHSIM Switch master SIM
Response
Test Command +SWITCHSIM: (0: SIM1, 1: SIM2)
AT+SWITCHSIM=?
OK
Response
Read Command +SWITCHSIM: <simID>
AT+SWITCHSIM?
OK
Response
1)If the parameter is correct,and the corresponding card has been
Write Command inserted, response:
AT+SWITCHSIM=<simID> OK
2)Others:
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

Defined Values

<simID> Integer type


0 SIM1
1 SIM2

Examples

AT+SWITCHSIM=?
+SWITCHSIM: (0: SIM1, 1: SIM2)
www.simcom.com 155 / 483
A76XX Series_AT Command Manual_V1.04

OK
AT+SWITCHSIM?
+SWITCHSIM: 0

OK
AT+SWITCHSIM=1
OK

AT+DUALSIM Set dual-sim mode

This command to set the dual-sim mode is dual standby or single standby.The SIM2 will register IMS when
<dsmode>=3,if it support.
AT+DUALSIM Set dual-sim mode
Response
+DUALSIM: (0: DUAL SIM DUAL STANDBY, 1: DUAL SIM
Test Command
SINGLE STANDBY, 3: DUAL SIM DUAL STANDBY FP)
AT+DUALSIM=?

OK
Response
Read Command +DUALSIM: <dsmode>
AT+DUALSIM?
OK
Response
1)If the parameter is correct, response:
Write Command
OK
AT+DUALSIM=<dsmode>
2)Others:
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

Defined Values

<dsmode> Integer type


0 Dual SIM dual standby
1 Dual SIM single standby
3 Dual SIM dual standby with extras

Examples
www.simcom.com 156 / 483
A76XX Series_AT Command Manual_V1.04

AT+DUALSIM=?
+DUALSIM: (0: DUAL SIM DUAL STANDBY, 1:
DUAL SIM SINGLE STANDBY, 3: DUAL SIM
DUAL STANDBY FP)

OK
AT+DUALSIM?
+DUALSIM: 0

OK
AT+DUALSIM=0
OK

AT+BINDSIM Bind ATP to SIM1 or SIM2

This set command to bind AT channel to SIM card 1 or SIM card 2.Only for AT interface.
AT+BINDSIM Bind ATP to SIM1 or SIM2
Response
Test Command +BINDSIM: (0: SIM1, 1: SIM2)
AT+BINDSIM=?
OK
Response
Read Command +BINDSIM: <simID>
AT+BINDSIM?
OK
Response
1)If the parameter is correct, response:
Write Command
OK
AT+BINDSIM=<simID>
2)Others:
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

Defined Values

<simID> Integer type


0 SIM1
1 SIM2

www.simcom.com 157 / 483


A76XX Series_AT Command Manual_V1.04

Examples

AT+BINDSIM=?
+BINDSIM: (0: SIM1, 1: SIM2)

OK
AT+BINDSIM?
+BINDSIM: 0

OK
AT+BINDSIM=0
OK
AT+CIMI
460003064859756

OK
AT+BINDSIM=1
OK
AT+CIMI
460012360528428

OK

www.simcom.com 158 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for Call Control


Overview of AT Commands for Call Control

Command Description
AT+CVHU Voice hang up control
AT+CHUP Hang up call
AT+CBST Select bearer service type
AT+CRLP Radio link protocol
AT+CRC Cellular result codes
AT+CLCC List current calls
AT+CEER Extended error report
AT+CCWA Call waiting
AT+CCFC Call forwarding number and conditions
AT+CLIP Calling line identification presentation
AT+CLIR Calling line identification restriction
AT+COLP Connected line identification presentation
AT+VTS DTMF and tone generation
AT+VTD Tone duration
AT+CSTA Select type of address
AT+CMOD Call mode
AT+VMUTE Speaker mute contro
AT+CMUT Microphone mute control
AT+CSDVC Switch voice channel device
AT+CMICGAIN Adjust mic gain
AT+COUTGAIN Adjust out gain

Detailed Description of AT Commands for Call Control

AT+CVHU Voice hang up control

www.simcom.com 159 / 483


A76XX Series_AT Command Manual_V1.04

Write command selects whether ATH or "drop DTR" shall cause a voice connection to be disconnected or
not. By voice connection is also meant alternating mode calls that are currently in voice mode.

AT+CVHU Voice hang up control


Response
Test Command +CVHU: (range of supported <mode>s)
AT+CVHU=?
OK
Response
Read Command +CVHU: <mode>
AT+CVHU?
OK
Response
1)
Write Command
OK
AT+CVHU=<mode>
2)
ERROR
Set default value
Execution Command
Response
AT+CVHU
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<mode> 0 "Drop DTR" ignored but OK response given. ATH disconnects.


1 "Drop DTR" and ATH ignored but OK response given.

Examples

AT+CVHU=?
+CVHU: (0-1)

OK
AT+CVHU?
+CVHU: 1

OK
AT+CVHU=0
OK
AT+CVHU

www.simcom.com 160 / 483


A76XX Series_AT Command Manual_V1.04

OK

AT+CHUP Hang up call

This command is used to cancel voice calls. If there is no call, it will do nothing but OK response is given.
After running AT+CHUP, multiple "VOICE CALL END: " may be reported which relies on how many calls
exist before calling this command.

AT+CHUP Hang up call


Test Command Response
AT+CHUP=? OK
Response
1)
OK
Execution Command
AT+CHUP
VOICE CALL: END: <time>
2)No Call
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<time> Voice call connection time.


Format HHMMSS (HH: hour, MM: minute, SS: second)

Examples

AT+CHUP=?
OK
AT+CHUP
OK

VOICE CALL: END: 000033

www.simcom.com 161 / 483


A76XX Series_AT Command Manual_V1.04

AT+CBST Select bearer service type

Write command selects the bearer service <name> with data rate <speed>, and the connection element
<ce> to be used when data calls are originated. Values may also be used during mobile terminated data call
setup, especially in case of single numbering scheme calls.

AT+CBST Select bearer service type


Response
+CBST: (list of supported <speed>s),(list of supported
Test Command
<name>s),(list of supported <ce>s)
AT+CBST=?

OK
Response
Read Command +CBST: <speed>,<name>,<ce>
AT+CBST?
OK
Response
1)
Write Command +CBST: <speed>,<name>,<ce>
AT+CBST=<speed>[,<name>
[,<ce>]] OK
2)
ERROR
Set default value
Execution Command
Response
AT+CBST
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<speed> 0 autobauding(automatic selection of the speed; this setting is


possible in case of 3.1 kHz modem and
non-transparent service)
1 300 bps (V.21)
2 1200 bps (V.22)
3 1200/75 bps (V.23)
4 2400 bps (V.22bis)
5 2400 bps (V.26ter)
6 4800 bps (V.32)
7 9600 bps (V.32)
12 9600 bps (V.34)
www.simcom.com 162 / 483
A76XX Series_AT Command Manual_V1.04

14 14400 bps (V.34)


15 19200 bps (V.34)
16 28800 bps (V.34)
17 33600 bps (V.34)
34 1200 bps (V.120)
36 2400 bps (V.120)
38 4800 bps (V.120)
39 9600 bps (V.120)
43 14400 bps (V.120)
47 19200 bps (V.120)
48 28800 bps (V.120)
49 38400 bps (V.120)
50 48000 bps (V.120)
51 56000 bps (V.120)
65 300 bps (V.110)
66 1200 bps (V.110)
68 2400 bps (V.110 or X.31 flag stuffing)
70 4800 bps (V.110 or X.31 flag stuffing)
71 9600 bps (V.110 or X.31 flag stuffing)
75 14400 bps (V.110 or X.31 flag stuffing)
79 19200 bps (V.110 or X.31 flag stuffing)
80 28800 bps (V.110 or X.31 flag stuffing)
81 38400 bps (V.110 or X.31 flag stuffing)
82 48000 bps (V.110 or X.31 flag stuffing)
83 56000 bps (V.110 or X.31 flag stuffing)
84 64000 bps (X.31 flag stuffing)
115 56000 bps (bit transparent)
116 64000 bps (bit transparent)
120 32000 bps (PIAFS32K)
121 64000 bps (PIAFS64K)
130 28800 bps (multimedia)
131 32000 bps (multimedia)
132 33600 bps (multimedia)
133 56000 bps (multimedia)
134 64000 bps (multimedia)
<name> 0 Asynchronous modem
1 Synchronous modem– PAD Access (asynchronous)( UDI)
2 Packet Access (synchronous )(UDI)
3 data circuit asynchronous (RDI)
4 data circuit synchronous (RDI)
5 PAD Access (asynchronous)(RDI)
6 Packet Access (synchronous )(RDI)
7 Packet Access (synchronous )(RDI)
<ce> 0 transparent
1 non-transparent

www.simcom.com 163 / 483


A76XX Series_AT Command Manual_V1.04

2 both, transparent preferred


3 both, non-transparent preferred

Examples

AT+CBST=?
+CBST:
(0,1,2,3,4,5,6,7,12,14,15,16,17,34,36,38,39,43,47
,48,49,50,51,65,66,68,70,71,75,79,80,81,82,83,8
4,115,116,120,121,130,131,132,133,134),(0-7),(0-
3)

OK
AT+CBST?
+CBST: 0,0,1

OK
AT+CBST=0,2,1
OK
AT+CBST
OK

NOTE

Not all combinations of these subparameters are supported.

AT+CRLP Radio link protocol

Radio Link Protocol(RLP)parameters used when non-transparent data calls are originated may be altered
with write command.

AT+CRLP Radio link protocol


Response
+CRLP: (range of supported <iws>s),(range of supported
Test Command <mws>s),(range of supported <T1>s),(range of supported
AT+CRLP=? <N2>s)[,<ver>[,(range of supported <T4>s)]]

OK

www.simcom.com 164 / 483


A76XX Series_AT Command Manual_V1.04

Response
Read Command +CRLP: <iws>,<mws>,<T1>,<N2>[,<ver>[,<T4>]]
AT+CRLP?
OK
Response
Write Command 1)
AT+CRLP=<iws>[,<mws>[,< OK
T1>[,<N2>[,<ver>[,<T4>]]]]] 2)
ERROR
Set default value
Execution Command
Response
AT+CRLP
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<ver> RLP version number in integer format, and it can be 0 or 1; when


version indication is not present it shall equal 1.
<iws> IWF to MS window size.
<mws> MS to IWF window size.
<T1> Acknowledgement timer.
<N2> Retransmission attempts.
<T4> Re-sequencing period in integer format.

Examples

AT+CRLP=?
+CRLP: (0-61),(0-61),(39-255),(1-255),(0-1),(3-255)

OK
AT+CRLP?
+CRLP: 61,61,128,255,1,3

OK
AT+CRLP=61,61,128,255,1,3
OK
AT+CRLP
OK

NOTE
www.simcom.com 165 / 483
A76XX Series_AT Command Manual_V1.04

<T1> and <T4> are in units of 10 ms.

AT+CRC Cellular result codes

Write command controls whether or not the extended format of incoming call indication or GPRS network
request for PDP context activation is used. When enabled, an incoming call is indicated to the TE with
unsolicited result code "+CRING: <type>" instead of the normal RING.
Test command returns values supported by the TA as a compound value.

AT+CRC Cellular result codes


Response
Test Command +CRC: (list of supported <mode>s)
AT+CRC=?
OK
Response
Read Command +CRC: <mode>
AT+CRC?
OK
Response
1)
Write Command
OK
AT+CRC=<mode>
2)
+CME ERROR: <err>
Set default value
Execution Command
Response
AT+CRC
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<mode> 0 disables reporting


1 enables reporting
<type> ASYNC asynchronous transparent
SYNC synchronous transparent
REL ASYNC asynchronous non-transparent

www.simcom.com 166 / 483


A76XX Series_AT Command Manual_V1.04

REL SYNC synchronous non-transparent


FAX facsimile
VOICE normal voice
VOICE/XXX voice followed by data(XXX is ASYNC, SYNC, REL
ASYNC or REL SYNC)
ALT VOICE/XXX alternating voice/data, voice first
ALT XXX/VOICE alternating voice/data, data first
ALT FAX/VOICE alternating voice/fax, fax first

Examples

AT+CRC=?
+CRC: (0,1)

OK
AT+CRC?
+CRC: 0

OK
AT+CRC=1
OK
AT+CRC
OK

AT+CLCC List current calls

This command is used to return list of current calls of ME. If command succeeds but no calls are available,
no information response is sent to TE.

AT+CLCC List current calls


Response
Test Command +CLCC: (range of supported <n>s)
AT+CLCC=?
OK
Response
Read Command +CLCC: <n>
AT+CLCC?
OK
Write Command Response
AT+CLCC=<n> 1)

www.simcom.com 167 / 483


A76XX Series_AT Command Manual_V1.04

OK
2)
ERROR
Response
1)
+CLCC:
<id1>,<dir>,<stat>,<mode>,<mpty>[,<number>,<type>[,<alph
Execution Command
a>]]
AT+CLCC

OK
2)
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

URC Description
+CLCC: Note:This can be an indication to list the
<id1>,<dir>,<stat>,<mode>,<mpty>[,<number>,<type>[ current call information when <n> set to 1.
,<alpha>]][
+CLCC:
<id2>,<dir>,<stat>,<mode>,<mpty>[,<number>,<type>[
,<alpha>]]

Defined Values

<n> 0 Don’t report a list of current calls of ME automatically when the


current call status changes.
1 Report a list of current calls of ME automatically when the
current call status changes.
<idX> Integer type, call identification number.
<dir> 0 mobile originated (MO)call
1 mobile terminated (MT)call
<stat> State of the call:
0 active
1 held
2 dialing (MO call)
3 alerting (MO call)
4 incoming (MT call)
5 waiting (MT call)
6 disconnect
<mode> bearer/teleservice:
0 voice
www.simcom.com 168 / 483
A76XX Series_AT Command Manual_V1.04

1 data
2 fax
9 unknown
<mpty> 0 call is not one of multiparty (conference)call parties
1 call is one of multiparty (conference)call parties
<number> String type phone number in format specified by <type>.
<type> Type of address octet in integer format;
128 Restricted number type includes unknown type and format
145 International number type
161 national number.The network support for this type is
optional
177 network specific number,ISDN format
129 Otherwise
<alpha> String type alphanumeric representation of <number> corresponding
to the entry found in phonebook; used character set should be the one
selected with command Select TE Character Set AT+CSCS.

Examples

AT+CLCC=?
+CLCC: (0-1)

OK
AT+CLCC?
+CLCC: 1

OK
AT+CLCC=1
OK
AT+CLCC
OK
AT+CLCC
+CLCC: 1, 0, 0, 0, 0, "13883113271", 129

OK

AT+CEER Extended error report

Execution command causes the TA to return the information text <report>, which should offer the user of the
TA an extended report of the reason for:
1. The failure in the last unsuccessful call setup(originating or answering)or in-call modification.

www.simcom.com 169 / 483


A76XX Series_AT Command Manual_V1.04

2. The last call release.


3. The last unsuccessful GPRS attach or unsuccessful PDP context activation.
4. The last GPRS detach or PDP context deactivation.

AT+CEER Extended error report


Test Command Response
AT+CEER=? OK
Response
Execution Command +CEER: <report>
AT+CEER
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<report> Wrong information which is possibly occurred.

Examples

AT+CEER=?
OK
AT+CEER
+CEER: "31 Normal unspecified"

OK

AT+CCWA Call waiting

This command allows control of the Call Waiting supplementary service. Activation, deactivation and status
query are supported. When querying the status of a network service (<mode>=2)the response line for 'not
active' case (<status>=0)should be returned only if service is not active for any <class>. Parameter <n> is
used to disable/enable the presentation of an unsolicited result code +CCWA: <number>,<type>,<class> to
the TE when call waiting service is enabled. Command should be abortable when network is interrogated.

AT+CCWA Call waiting


Test Command Response
AT+CCWA=? +CCWA: (range of supported <n>s),(range of supported

www.simcom.com 170 / 483


A76XX Series_AT Command Manual_V1.04

<mode>s),(range of supported <class>s)

OK
Response
Read Command +CCWA: <n>
AT+CCWA?
OK
Response
1)When <mode>=2 and command successful:
+CCWA: <status>,<class>[
+CCWA: <status>,<class>[..]]
Write Command
AT+CCWA=<n>[,<mode>[,<c
OK
lass>]]
2)
OK
3)
+CME ERROR: <err>
Set default value
Execution Command
Response
AT+CCWA
OK
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<n> Sets/shows the result code presentation status in the TA


0 disable
1 enable
<mode> When <mode> parameter is not given, network is not interrogated:
0 disable
1 enable
2 query status
<class> It is a sum of integers each representing a class of information (default
7)
1 voice (telephony)
2 data (refers to all bearer services)
4 fax (facsimile services)
7 voice,data and fax(1+2+4)
8 short message service
16 data circuit sync
32 data circuit async
64 dedicated packet access

www.simcom.com 171 / 483


A76XX Series_AT Command Manual_V1.04

128 dedicated PAD access


255 The value 255 covers all classes
<status> 0 not active
1 active
<number> String type phone number of calling address in format specified by
<type>.
<type> Type of address octet in integer format;
128 Restricted number type includes unknown type and format
145 International number type
129 Otherwise

Examples

AT+CCWA=?
+CCWA: (0-1),(0-2),(1-255)

OK
AT+CCWA?
+CCWA: 1

OK
AT+CCWA=1
OK
AT+CCWA=1,2,7
+CCWA: 1,1
+CCWA: 0,2
+CCWA: 0,4

OK
AT+CCWA
OK

AT+CCFC Call forwarding number and conditions

This command allows control of the call forwarding supplementary service. Registration, erasure, activation,
deactivation, and status query are supported.

AT+CCFC Call forwarding number and conditions


Test Command Response
AT+CCFC=? +CCFC: (list of supported <reason>s)

www.simcom.com 172 / 483


A76XX Series_AT Command Manual_V1.04

OK
Response
1)When <mode>=2 and command successful:
+CCFC:
<status>,<class1>[,<number>,<type>[,<subaddr>,<satype>[,<tim
e>]]][
+CCFC:
Write Command
<status>,<class2>[,<number>,<type>[,<subaddr>,<satype>[,<tim
AT+CCFC=<reason>,<mode
e>]]][..]]
>[,<number>[,<type>[,<class
>[,<subaddr>[,<satype>[,<ti
OK
me>]]]]]]
2)
OK
3)
ERROR
4)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<reason> 0 unconditional
1 mobile busy
2 no reply
3 not reachable
4 all call forwarding
5 all conditional call forwarding
<mode> 0 disable
1 enable
2 query status
3 registration
4 erasure
<number> String type phone number of forwarding address in format specified by
<type>.
<type> Type of address octet in integer format:
145 dialing string <number> includes international access code
character ‘+’
129 otherwise
<subaddr> String type sub address of format specified by <satype>.
<satype> Type of sub address octet in integer format, default 128.

www.simcom.com 173 / 483


A76XX Series_AT Command Manual_V1.04

<classX> It is a sum of integers each representing a class of information (default


7):
1 voice (telephony)
2 data (refers to all bearer services)
4 fax (facsimile services)
16 data circuit sync
32 data circuit async
64 dedicated packet access
128 dedicated PAD access
255 The value 255 covers all classes
<time> 1..30 when "no reply" is enabled or queried, this gives the time in
seconds to wait before call is forwarded, default value 20.
<status> 0 not active
1 active

Examples

AT+CCFC=?
+CCFC: (0,1,2,3,4,5)

OK
AT+CCFC=0,2
+CCFC: 0,7

OK

AT+CLIP Calling line identification presentation

This command refers to the GSM/UMTS supplementary service CLIP (Calling Line Identification
Presentation)that enables a called subscriber to get the calling line identity (CLI)of the calling party when
receiving a mobile terminated call.
Write command enables or disables the presentation of the CLI at the TE. It has no effect on the execution
of the supplementary service CLIP in the network.
When the presentation of the CLI at the TE is enabled (and calling subscriber allows), +CLIP:
<number>,<type>,,[,[<alpha>][,<CLI validity>]] response is returned after every RING (or +CRING: <type>;
refer sub clause "Cellular result codes +CRC")result code sent from TA to TE. It is manufacturer specific if
this response is used when normal voice call is answered.

AT+CLIP Calling line identification presentation


Test Command Response
AT+CLIP=? +CLIP: (range of supported <n>s)

www.simcom.com 174 / 483


A76XX Series_AT Command Manual_V1.04

OK
Response
1)
+CLIP: <n>,<m>

Read Command
OK
AT+CLIP?
2)
ERROR
3)
+CME ERROR: <err>
Response
1)
OK
Write Command
2)
AT+CLIP=<n>
ERROR
3)
+CME ERROR: <err>
Set default value
Execution Command
Response
AT+CLIP
OK
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<n> Parameter sets/shows the result code presentation status in the TA:
0 disable
1 enable
<m> 0 CLIP not provisioned
1 CLIP provisioned
2 unknown (e.g. no network, etc.)
<number> String type phone number of calling address in format specified by
<type>.
<type> Type of address octet in integer format;
128 Restricted number type includes unknown type and format
145 International number type
161 national number.The network support for this type is
optional
177 network specific number,ISDN format
129 Otherwise
<alpha> String type alphanumeric representation of <number> corresponding

www.simcom.com 175 / 483


A76XX Series_AT Command Manual_V1.04

to the entry found in phone book.


<CLI validity> 0 CLI valid
1 CLI has been withheld by the originator
2 CLI is not available due to interworking problems or limitations
of originating network

Examples

AT+CLIP=?
+CLIP: (0-1)

OK
AT+CLIP?
+CLIP: 1,1

OK
AT+CLIP=0
OK
AT+CLIP
OK

AT+CLIR Calling line identification restriction

This command refers to CLIR-service that allows a calling subscriber to enable or disable the presentation
of the CLI to the called party when originating a call.
Write command overrides the CLIR subscription (default is restricted or allowed)when temporary mode is
provisioned as a default adjustment for all following outgoing calls. This adjustment can be revoked by
using the opposite command. If this command is used by a subscriber without provision of CLIR in
permanent mode the network will act.
Read command gives the default adjustment for all outgoing calls (given in <n>), and also triggers an
interrogation of the provision status of the CLIR service (given in <m>).
Test command returns values supported as a compound value.

AT+CLIR Calling line identification restriction


Response
Test Command +CLIR: (range of supported <n>s)
AT+CLIR=?
OK
Read Command Response
AT+CLIR? 1)

www.simcom.com 176 / 483


A76XX Series_AT Command Manual_V1.04

+CLIR: <n>,<m>

OK
2)
ERROR
3)
+CME ERROR: <err>
Response
1)
OK
Write Command
2)
AT+CLIR=<n>
ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<n> 0 presentation indicator is used according to the subscription of


the CLIR service
1 CLIR invocation
2 CLIR suppression
<m> 0 CLIR not provisioned
1 CLIR provisioned in permanent mode
2 unknown (e.g. no network, etc.)
3 CLIR temporary mode presentation restricted
4 CLIR temporary mode presentation allowed

Examples

AT+CLIR=?
+CLIR: (0-2)

OK
AT+CLIR?
+CLIR: 0,0

OK
AT+CLIR=1
OK

www.simcom.com 177 / 483


A76XX Series_AT Command Manual_V1.04

AT+COLP Connected line identification presentation

This command refers to the GSM/UMTS supplementary service COLP(Connected Line Identification
Presentation)that enables a calling subscriber to get the connected line identity (COL)of the called party
after setting up a mobile originated call. The command enables or disables the presentation of the COL at
the TE. It has no effect on the execution of the supplementary service COLR in the network.
When enabled (and called subscriber allows), +COLP: <number>,<type>[,<subaddr>,<satype>[,<alpha>]]
intermediate result code is returned from TA to TE before any +CR responses. It is manufacturer specific if
this response is used when normal voice call is established.

AT+COLP Connected line identification presentation


Response
Test Command +COLP: (list of supported <n>s)
AT+COLP=?
OK
Response
1)
+COLP: <n>,<m>

Read Command
OK
AT+COLP?
2)
ERROR
3)
+CME ERROR: <err>
Response
1)
OK
Write Command
2)
AT+COLP=<n>
ERROR
3)
+CME ERROR: <err>
Set default value
Execution Command
Response
AT+COLP
OK
Parameter Saving Mode AUTO_SAVE
Max Response Time 20S
Reference 3GPP TS 27.007

Defined Values
www.simcom.com 178 / 483
A76XX Series_AT Command Manual_V1.04

<n> Parameter sets/shows the result code presentation status in the TA:
0 disable
1 enable
<m> 0 COLP not provisioned
1 COLP provisioned
2 unknown (e.g. no network, etc.)

Examples

AT+COLP=?
+COLP: (0-1)

OK
AT+COLP?
+COLP: 1,0

OK
AT+COLP=1
OK
AT+COLP
OK

AT+VTS DTMF and tone generation

This command allows the transmission of DTMF tones and arbitrary tones which cause the Mobile
Switching Center (MSC)to transmit tones to a remote subscriber. The command can only be used in voice
mode of operation (active voice call).

AT+VTS DTMF and tone generation


Response
Test Command +VTS: (list of supported<dtmf>s)
AT+VTS=?
OK
Response
Write Command
1)
AT+VTS=<dtmf>[,<duration>
OK
]
2)
or
ERROR
AT+VTS=<dtmf-string>
3)

www.simcom.com 179 / 483


A76XX Series_AT Command Manual_V1.04

+CME ERROR: <err>


Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<dtmf> A single ASCII character in the set 0-9, *, #, A, B, C, D.


<duration> Tone duration in 1/10 seconds, from 300 to 600. This is interpreted as
a DTMF tone of different duration from that mandated by the AT+VTD
command, otherwise, the duration which be set the AT+VTD
command will be used for the tone (<duration> is omitted).
<dtmf-string> A sequence of ASCII character in the set 0-9, *, #, A, B, C, D, and
maximal length of the string is 32. The string must be enclosed in
double quotes (""). Each of the tones with a duration which is set by
the AT+VTD command.

Examples

AT+VTS=?
+VTS: (0-9,*,#,A,B,C,D)

OK
AT+VTS=1,600
OK
AT+VTS="135"
OK

NOTE

The END event of voice call will terminate the transmission of tones, and as an operator option, the
tone may be ceased after a pre-determined time whether or not tone duration has been reached.

AT+VTD Tone duration

This refers to an integer <n> that defines the length of tones emitted as a result of the AT+VTS command. A
value different than zero causes a tone of duration <n>/10 seconds.

www.simcom.com 180 / 483


A76XX Series_AT Command Manual_V1.04

AT+VTD Tone duration


Response
Test Command +VTD: (range of supported <n>s)
AT+VTD=?
OK
Response
Read Command +VTD: <n>
AT+VTD?
OK
Response
1)
OK
Write Command
2)
AT+VTD=<n>
ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<n> 300-600 Tone duration of every single tone in 1/10 seconds.

Examples

AT+VTD=?
+VTD: (300-600)

OK
AT+VTD?
+VTD: 300

OK
AT+VTD=400
OK

www.simcom.com 181 / 483


A76XX Series_AT Command Manual_V1.04

AT+CSTA Select type of address

Write command is used to select the type of number for further dialing commands (ATD)according to
GSM/UMTS specifications.
Read command returns the current type of number.
Test command returns values supported by the Module as a compound value.

AT+CSTA Select type of address


Response
Test Command +CSTA: (list of supported <type>s)
AT+CSTA=?
OK
Response
Read Command +CSTA: <type>
AT+CSTA?
OK
Response
1)
Write Command
OK
AT+CSTA=<type>
2)
ERROR
Set default value
Execution Command
Response
AT+CSTA
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<type> Type of address octet in integer format:


145 when dialling string includes international access code
character "+"
161 national number.The network support for this type is
optional
177 network specific number,ISDN format
129 otherwise

Examples

AT+CSTA=?

www.simcom.com 182 / 483


A76XX Series_AT Command Manual_V1.04

+CSTA: (129,145,161,177)

OK
AT+CSTA?
+CSTA: 129

OK
AT+CSTA=145
OK
AT+CSTA
OK

NOTE

Because the type of address is automatically detected on the dial string of dialing command, command
AT+CSTA has really no effect.

AT+CMOD Call mode

Write command selects the call mode of further dialing commands (ATD)or for next answering command
(ATA). Mode can be either single or alternating.
Test command returns values supported by the TA as a compound value.

AT+CMOD Call mode


Response
Test Command +CMOD: (list of supported <mode>s)
AT+CMOD=?
OK
Response
Read Command +CMOD: <mode>
AT+CMOD?
OK
Response
1)
Write Command
OK
AT+CMOD=<mode>
2)
ERROR
Execution Command Set default value:
AT+CMOD Response

www.simcom.com 183 / 483


A76XX Series_AT Command Manual_V1.04

OK
Parameter Saving Mode -
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<mode> 0 single mode(only supported)

Examples

AT+CMOD=?
+CMOD: (0)

OK
AT+CMOD?
+CMOD: 0

OK
AT+CMOD=0
OK
AT+CMOD
OK

NOTE

The value of <mode> shall be set to zero after a successfully completed alternating mode call. It shall
be set to zero also after a failed answering. The power-on, factory and user resets shall also set the
value to zero. This reduces the possibility that alternating mode calls are originated or answered
accidentally.

AT+VMUTE Speaker mute control

This command is used to control the loudspeaker to mute and unmute during a voice call or a video call
which is connected. If there is not a connected call, write command can’t be used. When all calls are
disconnected, the Module sets the subparameter as 0 automatically.

www.simcom.com 184 / 483


A76XX Series_AT Command Manual_V1.04

AT+VMUTE Speaker mute control


Response
Test Command +VMUTE: (list of supported <mode>s)
AT+VMUTE=?
OK
Response
Read Command +VMUTE: <mode>
AT+VMUTE?
OK
Write Command Response
AT+VMUTE=<mode> OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<mode> 0 mute off


1 mute on

Examples

AT+VMUTE=?
+VMUTE: (0-1)

OK
AT+VMUTE?
+VMUTE: 0

OK
AT+VMUTE=1
OK

AT+CMUT Microphone mute control

This command is used to enable and disable the uplink voice muting during a voice call or a video call which
is connected. If there is not a connected call, write command can’t be used. When all calls are disconnected,
the Module sets the subparameter as 0 automatically.

www.simcom.com 185 / 483


A76XX Series_AT Command Manual_V1.04

AT+CMUT Microphone mute control


Response
Test Command +CMUT: (list of supported <mode>s)
AT+CMUT=?
OK
Response
Read Command +CMUT: <mode>
AT+CMUT?
OK
Write Command Response
AT+CMUT=<mode> OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<mode> 0 mute off


1 mute on

Examples

AT+CMUT=?
+CMUT: (0-1)

OK
AT+CMUT?
+CMUT: 0

OK
AT+CMUT=1
OK

AT+CSDVC Switch voice channel device

This command is used to switch voice channel device. After changing current voice channel device and if
there is a connecting voice call, it will use the settings of previous device (loudspeaker volume level, mute
state of loudspeaker and microphone, refer to AT+VMUTE, and AT+CMUT).

www.simcom.com 186 / 483


A76XX Series_AT Command Manual_V1.04

AT+CSDVC Switch voice channel device


Response
Test Command +CSDVC: (list of supported <dev>s)
AT+CSDVC=?
OK
Response
Read Command +CSDVC: <dev>
AT+CSDVC?
OK
Write Command Response
AT+CSDVC=<dev> OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<dev> 1 handset
3 speaker phone

Examples

AT+CSDVC=?
+CSDVC: (1,3)

OK
AT+CSDVC?
+CSDVC: 1

OK
AT+CSDVC=3
OK

AT+CMICGAIN Adjust mic gain

This command is used to adjust mic gain. If this command was used during call, it will take immediate effect.
Otherwise, it will take effect in next call.

AT+CMICGAIN Adjust mic gain


www.simcom.com 187 / 483
A76XX Series_AT Command Manual_V1.04

Response
Test Command +CMICGAIN: (range of supported <value>s)
AT+CMICGAIN=?
OK
Response
Read Command +CMICGAIN: <value>
AT+CMICGAIN?
OK
Response
1)
Write Command
OK
AT+CMICGAIN=<value>
2)
ERROR
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<value> Gain value from 0-7, 7 is the max. 4 is the default value.

Examples

AT+CMICGAIN=?
+CMICGAIN: (0-7)

OK
AT+CMICGAIN?
+CMICGAIN: 4

OK
AT+CMICGAIN=7
OK

AT+COUTGAIN Adjust out gain

This command is used to adjust out(speaker/handset)gain. If this command was used during call, it will take
immediate effect . Otherwise, it will take effect in next call.

www.simcom.com 188 / 483


A76XX Series_AT Command Manual_V1.04

AT+COUTGAIN Adjust out gain


Response
Test Command +COUTGAIN: (range of supported <value>s)
AT+COUTGAIN=?
OK
Response
Read Command +COUTGAIN: <value>
AT+COUTGAIN?
OK
Response
1)
Write Command
OK
AT+COUTGAIN=<value>
2)
ERROR
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<mode> Gain value from 0-7, 7 is the max. 4 is the default value.

Examples

AT+COUTGAIN=?
+COUTGAIN: (0-7)

OK
AT+COUTGAIN?
+COUTGAIN: 4

OK
AT+COUTGAIN=7
OK

www.simcom.com 189 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for Phonebook


Overview of AT Commands for Phonebook

Command Description
AT+CPBS Select phonebook memory storage
AT+CPBR Read phonebook entries
AT+CPBF Find phonebook entries
AT+CPBW Write phonebook entry
AT+CNUM Subscriber number

Detailed Description of AT Commands for Phonebook

AT+CPBS Select phonebook memory storage

This command selects the active phonebook storage, i.e. the phonebook storage that all subsequent
phonebook commands will be operating on.

AT+CPBS Select phonebook memory storage


Response
Test Command +CPBS: (list of supported <storage>s)
AT+CPBS=?
OK
Response
1)
+CPBS: <storage>[,<used>,<total>]
Read Command
AT+CPBS?
OK
2)
+CME ERROR: <err>
Write Command Response
AT+CPBS=<storage> 1)

www.simcom.com 190 / 483


A76XX Series_AT Command Manual_V1.04

OK
2)
ERROR
3)
+CME ERROR: <err>
Set default value "SM"
Execution Command
Response
AT+CPBS
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<storage> Values reserved by the present document:


"FD" SIM/USIM fix dialing phonebook. If a SIM card is
present or if a UICC with an active GSM application is present,
the information in EFFDN under DFTelecom is selected. If a
UICC with an active USIM application is present, the information
in EFFDN under ADFUSIM is selected.
"ON" SIM (or MT)own numbers (MSISDNs)list (reading of
this storage may be available through +CNUM also). When
storing information in the SIM/UICC, if a SIM card is present or if
a UICC with an active GSM application is present, the
information in EFMSISDN under DFTelecom is selected. If a
UICC with an active USIM application is present, the information
in EFMSISDN under ADFUSIM is selected.
"SM" SIM/UICC phonebook. If a SIM card is present or if a
UICC with an active GSM application is present, the EFADN
under DFTelecom is selected. If a UICC with an active USIM
application is present, the global phonebook, DFPHONEBOOK
under DFTelecom is selected.
"AP" Selected application phonebook. If a UICC with an
active USIM application is present, the application phonebook,
DFPHONEBOOK under ADFUSIM is selected.
<used> Integer type value indicating the number of used locations in
selected memory.
<total> Integer type value indicating the total number of locations in
selected memory.

Examples

AT+CPBS=?

www.simcom.com 191 / 483


A76XX Series_AT Command Manual_V1.04

+CPBS: ("SM","FD","ON","AP")

OK
AT+CPBS?
+CPBS: "SM",8,500

OK
AT+CPBS="SM"
OK
AT+CPBS
OK

AT+CPBR Read phonebook entries

This command gets the record information from the selected memory storage in phonebook. If the storage
is selected as "SM" then the command will return the record in SIM phonebook, the same to others.

AT+CPBR Read phonebook entries


Response
1)
+CPBR: (<minIndex>-<maxIndex>), [<nlength>], [<tlength>]
Test Command
AT+CPBR=?
OK
2)
+CME ERROR: <err>
Response
1)
[+CPBR: <index>,<number>,<type>,<text>[
+CPBR: <index>,<number>,<type>,<text>[…]]]
Write Command
AT+CPBR=<index1>[,<index2>] OK
2)
ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values
www.simcom.com 192 / 483
A76XX Series_AT Command Manual_V1.04

<index1> Integer type value in the range of location numbers of phonebook


memory.
<index2> Integer type value in the range of location numbers of phonebook
memory.
<index> Integer type.the current position number of the Phonebook index.
<minIndex> Integer type the minimum <index> number.
<maxIndex> Integer type the maximum <index> number
<number> String type, phone number of format <type>, the maximum length is
<nlength>.
<type> Type of phone number octet in integer format, default 145 when
dialing string includes international access code character "+",
otherwise 129.
<text> String type field of maximum length <tlength>; often this value is set
as name.
<nlength> Integer type value indicating the maximum length of field <number>.
<tlength> Integer type value indicating the maximum length of field <text>.

Examples

AT+CPBR=?
+CPBR: (1-500),40,14

OK
AT+CPBR=3
+CPBR: 3,"1234567890123456789012345678901234567890",129,""

OK

AT+CPBF Find phonebook entries

This command finds the record in phonebook (from the current phonebook memory storage selected with
AT+CPBS)which alphanumeric field has substring <findtext>.If <findtext> is null, it will lists all the entries.

AT+CPBF Find phonebook entries


Response
1)
Test Command
+CPBF: [<nlength>],[<tlength>]
AT+CPBF=?

OK

www.simcom.com 193 / 483


A76XX Series_AT Command Manual_V1.04

2)
+CME ERROR: <err>
Response
1)
[+CPBF: <index1>,<number>,<type>,<text>[
+CPBF: <indexN>,<number>,<type>,<text>[…]]]
Write Command
AT+CPBF=[<findtext>]
OK
2)
ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<findtext> String type, this value is used to find the record. Character set
should be the one selected with command AT+CSCS.
<index> Integer type values in the range of location numbers of
phonebook memory.
<number> String type, phone number of format <type>, the maximum length
is <nlength>.
<type> Type of phone number octet in integer format, default 145 when
dialing string includes international access code character "+",
otherwise 129.
<text> String type field of maximum length <tlength>; often this value is
set as name.
<nlength> Integer type value indicating the maximum length of field
<number>.
<tlength> Integer type value indicating the maximum length of field <text>.

Examples

AT+CPBF=?
+CPBF: 40,14

OK
AT+CPBF="lly"
+CPBF: 500,"1234567890123456789012345678901234567890",129,"lly"

www.simcom.com 194 / 483


A76XX Series_AT Command Manual_V1.04

OK

AT+CPBW Write phonebook entry

This command writes phonebook entry in location number <index> in the current phonebook memory
storage selected with AT+CPBS.

AT+CPBW Write phonebook entry


Response
1)
+CPBW: (list of supported <index>s),[<nlength>],(list of supported
Test Command <type>s),[<tlength>]
AT+CPBW=?
OK
2)
+CME ERROR: <err>
Response
1)
Write Command OK
AT+CPBW=[<index>][,<number 2)
>[,<type>[,<text>]]] ERROR
3)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<index> Integer type values in the range of location numbers of phonebook


memory. If <index> is not given, the first free entry will be used. If
<index> is given as the only parameter, the phonebook entry
specified by <index> is deleted. If record number <index> already
exists, it will be overwritten.
<number> String type, phone number of format <type>, the maximum length is
<nlength>.It must be an non-empty string.
<type> Type of address octet in integer format, The range of value is from
129 to 255. If <number> contains a leading "+" <type>=145
(international)is used. Supported value are:
145 when dialling string includes international access code

www.simcom.com 195 / 483


A76XX Series_AT Command Manual_V1.04

character "+"
161 national number. The network support for this type is
optional
177 network specific number, ISDN format
129 otherwise

NOTE: Other value refer TS 24.008 [8] subclause 10.5.4.7.


<text> String type field of maximum length <tlength>; character set as
specified by command Select TE Character Set AT+CSCS.
<nlength> Integer type value indicating the maximum length of field <number>.
<tlength> Integer type value indicating the maximum length of field <text>.
<text> has a maximum of 14 bytes.
NOTE: If the parameters of <type> and <text> are omitted and the
first character of <number> is ‘+’,it will specify <type> as 145(129 if
the first character isn’t ‘+’)and <text> as NULL.

Examples

AT+CPBW=?
+CPBW: (1-500),40,(129,145,161,177),14

OK
AT+CPBW=493,"12345678901234567890",129,"lly1"
OK

AT+CNUM Subscriber number

Execution command returns the MSISDNs related to the subscriber (this information can be stored in the
SIM or in the ME). If subscriber has different MSISDN for different services, each MSISDN is returned in a
separate line.

AT+CNUM Subscriber number


Response
Test Command
1)
AT+CNUM=?
OK
Response
Write Command 1)
AT+CNUM=<index>[,<number>[ OK
,<type>[,<text>]]] 2)
+CME ERROR: <err>
Execution Command Response

www.simcom.com 196 / 483


A76XX Series_AT Command Manual_V1.04

AT+CNUM 1)
[+CNUM: <text>,<number>,<type>
+CNUM: <text>,<number>,<type>]

OK
2)
+CME ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.007

Defined Values

<index> Integer type values in the range (1, 2). If <index> is given as the
only parameter and is 1 or 2, the MSISDN specified by <index> is
deleted. If record number <index> already exists, it will be
overwritten.
<number> String type phone number of format specified by <type>.
<type> Type of address octet in integer format. Refer to the CPBW
<type>.
<text> String type field of maximum length <tlength>; character set as
specified by command Select TE Character Set AT+CSCS.

Examples

AT+CNUM=?
OK
AT+CNUM
OK

NOTE

CAT1 modules do not support Write Command.

www.simcom.com 197 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for SMS


Overview of AT Commands for SMS

Command Description
AT+CSMS Select message service
AT+CPMS Preferred message storage
AT+CMGF Select SMS message format
AT+CSCA SMS service centre address
AT+CSCB Select cell broadcast message indication
AT+CSMP Set text mode parameters
AT+CSDH Show text mode parameters
AT+CNMA New message acknowledgement to ME/TA
AT+CNMI New message indications to TE
AT+CGSMS Select service for MO SMS messages
AT+CMGL List SMS messages from preferred store
AT+CMGR Read message
AT+CMGS Send message
AT+CMSS Send message from storages
AT+CMGW Write message to memory
AT+CMGD Delete message
AT+CMGMT Change message status
AT+CMVP Set message valid period
AT+CMGRD Read and delete message
AT+CMGSEX Send message
AT+CMSSEX Send multi messages from storage

Command Description Supported Modules


AT+CSCB=<mode>,<mi Parameters are not allowed to be Only CAT1 Modules
ds>,<dcss> omitted
AT+CMGS Allow deleting input SMS data in data Only CAT1 Modules
AT+CMGW mode
AT+CMGSEX No SMS send URC report, just report a Only CAT1 Modules
OK before last SMS input.

www.simcom.com 198 / 483


A76XX Series_AT Command Manual_V1.04

Detailed Description of AT Commands for SMS

AT+CSMS Select message service

This command is used to select messaging service <service>.

AT+CSMS Select message service


Test Command Response
AT+CSMS=? +CSMS: (range of supported <service>s)

OK
Response
Read Command +CSMS: <service>,<mt>,<mo>,<bm>
AT+CSMS?
OK
Response
1)
+CSMS: <mt>,<mo>,<bm>

Write Command
OK
AT+CSMS=<service>
2)
ERROR
3)
+CMS ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.005

Defined Values

<service> 0 SMS at command is compatible with GSM phase 2.


1 SMS at command is compatible with GSM phase 2+.
<mt> 0 type not supported.
1 type supported.
<mo> 0 type not supported.
1 type supported.
<bm> 0 type not supported.
1 type supported.

www.simcom.com 199 / 483


A76XX Series_AT Command Manual_V1.04

Examples

AT+CSMS=0
+CSMS: 1,1,1

OK
AT+CSMS?
+CSMS: 0,1,1,1

OK
AT+CSMS=?
+CSMS: (0-1)

OK

AT+CPMS Preferred message storage

This command is used to select memory storages <mem1>,<mem2> and <mem3> to be used for reading,
writing, etc.

AT+CPMS Preferred message storage


Test Command Response
AT+CPMS=? +CPMS: (list of supported <mem1>s),(list of supported
<mem2>s),(list of supported <mem3>s)

OK
Response
+CPMS:
Read Command <mem1>,<used1>,<total1>,<mem2>,<used2>,<total2>,<mem3>,
AT+CPMS? <used3>,<total3>

OK
Response
1)
+CPMS: <used1>,<total1>,<used2>,<total2>,<used3>,<total3>
Write Command
AT+CPMS=<mem1>[,<mem2>[, OK
<mem3>]] 2)
ERROR
3)
+CMS ERROR: <err>
www.simcom.com 200 / 483
A76XX Series_AT Command Manual_V1.04

Response
1)Set default value
(<mem1>="SM",<mem2>="SM",<mem3>="SM"):
+CPMS: <used1>,<total1>,<used2>,<total2>,<used3>,<total3>
Execution Command
AT+CPMS OK
2)
ERROR
3)
+CMS ERROR: <err>
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.005

Defined Values

<mem1> String type, memory from which messages are read and deleted
(commands List Messages AT+CMGL, Read Message AT+CMGR
and Delete Message AT+CMGD).
"ME" FLASH message storage
"SM" SIM message storage
<mem2> String type, memory to which writing and sending operations are
made (commands Send Message from Storage AT+CMSS and
Write Message to Memory AT+CMGW).
"ME" FLASH message storage
"SM" SIM message storage
<mem3> String type, memory to which received SMS is preferred to be stored
(unless forwarded directly to TE; refer command New Message
Indications AT+CNMI).
"ME" FLASH message storage
"SM" SIM message storage
<bm> Integer type, number of messages currently in <memX>.
<totalX> Integer type, total number of message locations in <memX>.

Examples

AT+CPMS=?
+CPMS: ("ME","SM"),("ME","SM"),("ME","SM")

OK
AT+CPMS?
+CPMS: "ME", 0, 180,"ME", 0, 180,"ME", 0, 180

www.simcom.com 201 / 483


A76XX Series_AT Command Manual_V1.04

OK
AT+CPMS="SM","SM","SM"
+CPMS: 3,50,3,50,3,50

OK
AT+CPMS
+CPMS: 3,50,3,50,3,50

OK

AT+CMGF Select SMS message format

This command is used to specify the input and output format of the short messages.

AT+CMGF Select SMS message format


Test Command Response
AT+CMGF=? 1)
+CMGF: (range of supported <mode>s)

OK
2)
ERROR
Response
1)
+CMGF: <mode>
Read Command
AT+CMGF?
OK
2)
ERROR
Response
1)
Write Command
OK
AT+CMGF=<mode>
2)
ERROR
Response
1)
Execution Command Set default value (<mode>=0):
AT+CMGF OK
2)
ERROR
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms

www.simcom.com 202 / 483


A76XX Series_AT Command Manual_V1.04

Reference 3GPP TS 27.005

Defined Values

<mode> 0 PDU mode


1 Text mode

Examples

AT+CMGF?
+CMGF: 0

OK
AT+CMGF=?
+CMGF: (0-1)

OK
AT+CMGF=1
OK
AT+CMGF
OK

AT+CSCA SMS service centre address

This command is used to update the SMSC address, through which mobile originated SMS are transmitted.

AT+CSCA SMS service centre address


Test Command Response
AT+CSCA=? OK
Response
1)
+CSCA: <sca>,<tosca>
Read Command
AT+CSCA?
OK
2)
ERROR
Response
Write Command 1)
AT+CSCA=<sca>[,<tosca>] OK
2)

www.simcom.com 203 / 483


A76XX Series_AT Command Manual_V1.04

ERROR
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.005

Defined Values

<sca> Service Centre Address, value field in string format, BCD


numbers (or GSM 7 bit default alphabet characters)are converted
to characters of the currently selected TE character set (refer to
command AT+CSCS), type of address given by <tosca>.
<tosca> SC address Type-of-Address octet in integer format, when first
character of <sca> is + (IRA 43)default is 145, otherwise default
is 129.

Examples

AT+CSCA=?
OK
AT+CSCA="+8613012345678"
OK
AT+CSCA?
+CSCA: "+8613010314500", 145

OK

AT+CSCB Select cell broadcast message indication

The test command returns the supported <mode>s as a compound value.


The read command displays the accepted message types.
Depending on the <mode> parameter, the write command adds or deletes the message types accepted.

AT+CSCB Select cell broadcast message indication


Test Command Response
AT+CSCB=? 1)
+CSCB: (range of supported <mode>s)

OK
2)
ERROR
www.simcom.com 204 / 483
A76XX Series_AT Command Manual_V1.04

Response
1)
+CSCB: <mode>,<mids>,<dcss>
Read Command
AT+CSCB?
OK
2)
ERROR
Response
1)
Write Command OK
AT+CSCB=<mode>[,<mids>[,<d 2)
css>]] ERROR
3)
+CMS ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.005

Defined Values

<mode> 0 message types specified in <mids> and <dcss> are accepted.


1 message types specified in <mids> and <dcss> are not
accepted.
<mids> String type; all different possible combinations of CBM message
identifiers.
<dcss> String type; all different possible combinations of CBM data
coding schemes(default is empty string)

NOTE

The Read command for A7600 series return a list of available parameters <mids> and <dcss> with
<mode> 0. If no parameters are available, return <mode> 1.

Examples

AT+CSCB=?
+CSCB: (0-1)

OK
AT+CSCB?
+CSCB: 1,"",""

www.simcom.com 205 / 483


A76XX Series_AT Command Manual_V1.04

OK
AT+CSCB=0,"15-17,50,86",""
OK

AT+CSMP Set text mode parameters

This command is used to select values for additional parameters needed when SM is sent to the network or
placed in storage when text format message mode is selected.

AT+CSMP Set text mode parameters


Test Command Response
AT+CSMP=? OK
Response
1)
Read Command
+CSMP: <fo>,<vp>,<pid>,<dcs>
AT+CSMP?

OK
Response
Write Command 1)
AT+CSMP=<fo>[,<vp>[,<pid>[,< OK
dcs>]]] 2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.005

Defined Values

<fo> Depending on the Command or result code: first octet of GSM


03.40 SMS-DELIVER, SMS-SUBMIT (default 17),
SMS-STATUS-REPORT, or SMS-COMMAND (default 2)in
integer format. SMS status report is supported under text mode if
<fo> is set to 49.
<vp> Depending on SMS-SUBMIT <fo> setting: GSM
03.40,TP-Validity-Period either in integer format (default 167), in
time-string format, or if is supported, in enhanced format
(hexadecimal coded string with quotes),(<vp> is in range 0..
255).
<pid> GSM 03.40 TP-Protocol-Identifier in integer format (default 0).
www.simcom.com 206 / 483
A76XX Series_AT Command Manual_V1.04

<dcs> GSM 03.38 SMS Data Coding Scheme (default 0), or Cell
Broadcast Data Coding Scheme in integer format depending on
the command or result code.

Examples

AT+CSMP=17,23,0,244
OK
AT+CSMP?
+CSMP: 17,23,0,244

OK
AT+CSMP=?
OK

AT+CSDH Show text mode parameters

This command is used to control whether detailed header information is shown in text mode result codes.

AT+CSDH Show text mode parameters


Test Command Response
AT+CSDH=? +CSDH: (range of supported <show>s)

OK
Response
Read Command +CSDH: <show>
AT+CSDH?
OK
Response
1)
Write Command
OK
AT+CSDH=<show>
2)
ERROR
Set default value (<show>=0):
1)
Execution Command
OK
AT+CSDH
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.005

www.simcom.com 207 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<show> 0 do not show header values defined in commands AT+CSCA


and AT+CSMP (<sca>,<tosca>,<fo>,<vp>,<pid> and <dcs>)nor
<length>,<toda> or <tooa> in +CMT, AT+CMGL, AT+CMGR
result codes for SMS-DELIVERs and SMS-SUBMITs in text
mode; for SMS-COMMANDs in AT+CMGR result code, do not
show <pid>,<mn>,<da>,<toda>,<length> or <data>
1 show the values in result codes

Examples

AT+CSDH=?
+CSDH: (0-1)

OK
AT+CSDH?
+CSDH: 0

OK
AT+CSDH=1
OK
AT+CSDH
OK

AT+CNMA New message acknowledgement to ME/TA

This command is used to confirm successful receipt of a new message (SMS-DELIVER or


SMS-STATUSREPORT)routed directly to the TE. If ME does not receive acknowledgement within required
time (network timeout), it will send RP-ERROR to the network.

AT+CNMA New message acknowledgement to ME/TA


Test Command Response
AT+CNMA=? if text mode(AT+CMGF=1):
OK
if PDU mode (AT+CMGF=0):
+CNMA: (range of supported <n>s)

OK
Write Command Response

www.simcom.com 208 / 483


A76XX Series_AT Command Manual_V1.04

AT+CNMA=<n> 1)
OK
2)
ERROR
3)
+CMS ERROR: <err>
1)
OK
Execution Command 2)
AT+CNMA ERROR
3)
+CMS ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.005

Defined Values

<n> Parameter required only for PDU mode.


0 Command operates similarly as execution command in text
mode.
1 Send positive (RP-ACK)acknowledgement to the network.
Accepted only in PDU mode.
2 Send negative (RP-ERROR)acknowledgement to the
network. Accepted only in PDU mode.

Examples

AT+CNMI=1,2,0,0,0
OK

+CMT: "1380022xxxx","","02/04/03,11:06:38+32"
// receive new short message
Testing

AT+CNMA
//send ACK to the network
OK
//the second time return error, it needs ACK
AT+CNMA
only once
+CMS ERROR:340

NOTE

The execute / write command shall only be used when AT+CSMS parameter <service> equals 1 (= phase
2+)and appropriate URC has been issued by the module, i.e.:

www.simcom.com 209 / 483


A76XX Series_AT Command Manual_V1.04

<+CMT> for <mt>=2 incoming message classes 0, 1, 3 and none;


<+CMT> for <mt>=3 incoming message classes 0 and 3;
<+CDS> for <ds>=1.

AT+CNMI New message indications to TE

This command is used to select the procedure how receiving of new messages from the network is
indicated to the TE when TE is active, e.g. DTR signal is ON. If TE is inactive (e.g. DTR signal is OFF). If set
<mt>=3 or <ds>=1, make sure <mode>=1, If set <mt>=2,make sure <mode>=1 or 2, otherwise it will
return error.

AT+CNMI New message indications to TE


Test Command Response
AT+CNMI=? +CNMI: (list of supported <mode>s),(list of supported <mt>s),(list
of supported <bm>s),(list of supported <ds>s),(list of supported
<bfr>s)

OK
Response
Read Command +CNMI: <mode>,<mt>,<bm>,<ds>,<bfr>
AT+CNMI?
OK
Response
1)
Write Command OK
AT+CNMI=<mode>[,<mt>[,<bm> 2)
[,<ds>[,<bfr>]]]] ERROR
3)
+CMS ERROR: <err>
Execution Command Set default value:
AT+CNMI OK
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.005

Defined Values

<mode> 0 Buffer unsolicited result codes in the TA. If TA result code


buffer is full, indications can be buffered in some other place or
the oldest indications may be discarded and replaced with the
www.simcom.com 210 / 483
A76XX Series_AT Command Manual_V1.04

new received indications.


1 Discard indication and reject new received message
unsolicited result codes when TA-TE link is reserved (e.g. in
on-line data mode). Otherwise forward them directly to the TE.
2 Buffer unsolicited result codes in the TA when TA-TE link is
reserved (e.g. in on-line data mode)and flush them to the TE after
reservation. Otherwise forward them directly to the TE.
<mt> The rules for storing received SMS depend on its data coding
scheme, preferred memory storage (AT+CPMS)setting and this
value:
0 No SMS-DELIVER indications are routed to the TE.
1 If SMS-DELIVER is stored into ME/TA, indication of the
memory location is routed to the TE using unsolicited result code:
+CMTI: <mem3>,<index>.
2 SMS-DELIVERs (except class 2 messages and messages in
the message waiting indication group (store message))are routed
directly to the TE using unsolicited result code:
+CMT: [<alpha>],<length><CR><LF><pdu> (PDU mode
enabled); or
+CMT:
<oa>,[<alpha>],<scts>[,<tooa>,<fo>,<pid>,<dcs>,<sca>,<tosca>
,<length>]<CR> <LF><data>
(text mode enabled, about parameters in italics, refer command
Show Text Mode Parameters AT+CSDH).
3 Class 3 SMS-DELIVERs are routed directly to TE using
unsolicited result codes defined in <mt>=2. Messages of other
data coding schemes result in indication as defined in <mt>=1.
<bm> The rules for storing received CBMs depend on its data coding
scheme, the setting of Select CBM Types (AT+CSCB)and this
value:
0 No CBM indications are routed to the TE.
2 New CBMs are routed directly to the TE using unsolicited
result code:
+CBM: <length><CR><LF><pdu> (PDU mode enabled); or
+CBM: <sn>,<mid>,<dcs>,<page>,<pages><CR><LF><data>
(text mode enabled)
<ds> 0 No SMS-STATUS-REPORTs are routed to the TE.
1 SMS-STATUS-REPORTs are routed to the TE using
unsolicited result code:
+CDS: <length><CR><LF><pdu> (PDU mode enabled); or
+CDS: <fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st> (text mode
enabled)
2 If SMS-STATUS-REPORT is stored into ME/TA, indication of
the memory location is routed to the TE using unsolicited result
code: +CDSI: <mem3>,<index>.

www.simcom.com 211 / 483


A76XX Series_AT Command Manual_V1.04

<bfr> 0 TA buffer of unsolicited result codes defined within this


command is flushed to the TE when <mode> 1 to 2 is entered
(OK response shall be given before flushing the codes).
1 TA buffer of unsolicited result codes defined within this
command is cleared when <mode> 1 to 2 is entered.

Examples

AT+CNMI?
+CNMI: 2,1,0,0,0

OK
AT+CNMI=?
+CNMI: (0,1,2),(0,1,2,3),(0,2),(0,1,2),(0,1)

OK
AT+CNMI=2,1 (unsolicited result codes after
received messages.)
OK
AT+CNMI
OK

AT+CGSMS Select service for MO SMS messages

The write command is used to specify the service or service preference that the MT will use to send MO
SMS messages.
The test command is used for requesting information on which services and service preferences can be set
by using the AT+CGSMS write command
The read command returns the currently selected service or service preference.

AT+CGSMS Select service for MO SMS messages


Test Command Response
AT+CGSMS=? +CGSMS: (range of supported <service>s)

OK
Response
Read Command +CGSMS: <service>
AT+CGSMS?
OK
Write Command Response
AT+CGSMS=<service> 1)

www.simcom.com 212 / 483


A76XX Series_AT Command Manual_V1.04

OK
2)
ERROR
3)
+CMS ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.005

Defined Values

<service> A numeric parameter which indicates the service or service


preference to be used
0 GPRS(value is not really supported and is internally mapped
to 2)
1 circuit switched(value is not really supported and is internally
mapped to 3)
2 GPRS preferred (use circuit switched if GPRS not available)
3 circuit switched preferred (use GPRS if circuit switched not
available)

Examples

AT+CGSMS?
+CGSMS: 3

OK
AT+CGSMS=?
+CGSMS: (0-3)

OK
AT+CGSMS=3
OK

AT+CMGL List SMS messages from preferred store

This command is used to return messages with status value <stat> from message storage <mem1> to the
TE.

If the status of the message is 'received unread', the status in the storage changes to 'received read'.

www.simcom.com 213 / 483


A76XX Series_AT Command Manual_V1.04

AT+CMGL List SMS messages from preferred store


Test Command Response
AT+CMGL=? +CMGL: (list of supported <stat>s)

OK
Response
1)If text mode (AT+CMGF=1), command successful and
SMS-SUBMITs and/or SMS-DELIVERs:
+CMGL:
<index>,<stat>,<oa>/<da>,[<alpha>],[<scts>][,<tooa>/<toda>,<f
o>,<pid>,<dcs>,<sca>,<tosca>,<length>]<CR><LF><data>[
+CMGL:
<index>,<stat>,<oa>/<da>,[<alpha>],[<scts>][,<tooa>/<toda>,<f
o>,<pid>,<dcs>,<sca>,<tosca>,<length>]<CR><LF><data>[..]]

OK
2)If text mode (AT+CMGF=1), command successful and SMS-
STATUS-REPORTs:
+CMGL:
<index>,<stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st>[
+CMGL:
<index>,<stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st>[..]]

OK
Write Command
3)If text mode (AT+CMGF=1), command successful and SMS-
AT+CMGL=<stat>
COMMANDs:
+CMGL: <index>,<stat>,<fo>,<ct>[
+CMGL: <index>,<stat>,<fo>,<ct>[..]]

OK
4)If text mode (AT+CMGF=1), command successful and CBM
storage:
+CMGL: <index>,<stat>,<sn>,<mid>,<page>,<pages>
<data>[
+CMGL: <index>,<stat>,<sn>,<mid>,<page>,<pages>
<data>[..]]

OK
5)If PDU mode (AT+CMGF=0)and Command successful:
+CMGL: <index>,<stat>,[<alpha>],<length>
<pdu>[
+CMGL: <index>,<stat>,[<alpha>],<length>
<pdu>
[…]]

www.simcom.com 214 / 483


A76XX Series_AT Command Manual_V1.04

OK
6)
+CMS ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.005

Defined Values

<stat> 1. Text Mode:


"REC UNREAD" received unread message (i.e. new message)
"REC READ" received read message
"STO UNSENT" stored unsent message
"STO SENT" stored sent message
"ALL" all messages
2. PDU Mode:
0 received unread message (i.e. new message)
1 received read message
2 stored unsent message
3 stored sent message
4 all messages
<index> Integer type; value in the range of location numbers supported by
the associated memory and start with one.
<oa> Originating-Address, Address-Value field in string format; BCD
numbers (or GSM 7 bit default alphabet characters)are converted
to characters of the currently selected TE character set, type of
address given by <tooa>.
<da> Destination-Address, Address-Value field in string format; BCD
numbers (or GSM 7 bit default alphabet characters)are converted
to characters of the currently selected TE character set, type of
address given by <toda>.
<alpha> String type alphanumeric representation of <da> or <oa>
corresponding to the entry found in MT phonebook;
implementation of this feature is manufacturer specific; used
character set should be the one selected with command Select
TE Character Set AT+CSCS.
<scts> TP-Service-Centre-Time-Stamp in time-string format (refer <dt>).
<tooa> TP-Originating-Address, Type-of-Address octet in integer format.
(default refer <toda>).
<toda> TP-Destination-Address, Type-of-Address octet in integer format.
(when first character of <da> is + (IRA 43)default is 145,
otherwise default is 129). The range of value is from 128 to 255.
<length> Integer type value indicating in the text mode (AT+CMGF=1)the

www.simcom.com 215 / 483


A76XX Series_AT Command Manual_V1.04

length of the message body <data> in characters; or in PDU


mode (AT+CMGF=0), the length of the actual TP data unit in
octets. (i.e. the RP layer SMSC address octets are not counted in
the length)
<data> In the case of SMS: TP-User-Data in text mode responses;
format:
1. If <dcs> indicates that GSM 7 bit default alphabet is used and
<fo> indicates that TP-User-Data-Header-Indication is not set:
a. If TE character set other than "HEX": ME/TA converts GSM
alphabet into current TE character set.
b. If TE character set is "HEX": ME/TA converts each 7-bit
character of GSM 7 bit default alphabet into two IRA character
long hexadecimal numbers. (e.g. character (GSM 7 bit default
alphabet 23)is presented as 17 (IRA 49 and 55))
2. If <dcs> indicates that 8-bit or UCS2 data coding scheme is
used, or <fo> indicates that TP-User-Data-Header-Indication is
set: ME/TA converts each 8-bit octet into two IRA character long
hexadecimal numbers. (e.g. octet with integer value 42 is
presented to TE as two characters 2A (IRA 50 and 65))
3. If <dcs> indicates that GSM 7 bit default alphabet is used:
a. If TE character set other than "HEX": ME/TA converts GSM
alphabet into current TE character set.
b. If TE character set is "HEX": ME/TA converts each 7-bit
character of the GSM 7 bit default alphabet into two IRA
character long hexadecimal numbers.
4. If <dcs> indicates that 8-bit or UCS2 data coding scheme is
used: ME/TA converts each 8-bit octet into two IRA character
long hexadecimal numbers.
<fo> Depending on the command or result code: first octet of GSM
03.40 SMS-DELIVER, SMS-SUBMIT (default 17),
SMS-STATUS-REPORT, or SMS-COMMAND (default 2)in
integer format. SMS status report is supported under text mode if
<fo> is set to 49.
<mr> Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<ra> Recipient Address
GSM 03.40 TP-Recipient-Address Address-Value field in string
format;BCD numbers (or GSM default alphabet characters)are
converted to characters of the currently selected TE character
set(refer to command AT+CSCS);type of address given by <tora>
<tora> Type of Recipient Address
GSM 04.11 TP-Recipient-Address Type-of-Address octet in
integer format (default refer <toda>)
<dt> Discharge Time
GSM 03.40 TP-Discharge-Time in time-string

www.simcom.com 216 / 483


A76XX Series_AT Command Manual_V1.04

format:"yy/MM/dd,hh:mm:ss+zz",where characters indicate year


(two last digits),month,day,hour,minutes,seconds and time zone.
<st> Status
GSM 03.40 TP-Status in integer format
0…255
<ct> Status
GSM 03.40 TP-Status in integer format
0…255
<ct> Command Type
GSM 03.40 TP-Command-Type in integer format
0…255
<sn> Serial Number
GSM 03.41 CBM Serial Number in integer format
<mid> Message Identifier
GSM 03.41 CBM Message Identifier in integer format
<page> Page Parameter
GSM 03.41 CBM Page Parameter bits 4-7 in integer format
<pages> Page Parameter
GSM 03.41 CBM Page Parameter bits 0-3 in integer format
<pdu> In the case of SMS: SC address followed by TPDU in
hexadecimal format: ME/TA converts each octet of TP data unit
into two IRA character long hexadecimal numbers. (e.g. octet
with integer value 42 is presented to TE as two characters 2A
(IRA 50 and 65)).

Examples

AT+CMGL=?
+CMGL: ("REC UNREAD","REC READ","STO UNSENT","STO SENT","ALL")

OK
AT+CMGL="ALL"
+CMGL: 1,"STO UNSENT","+10011",,,145,4
Hello World

OK

AT+CMGR Read message

This command is used to return message with location value <index> from message storage <mem1> to
the TE.

www.simcom.com 217 / 483


A76XX Series_AT Command Manual_V1.04

AT+CMGR Read message


Test Command Response
AT+CMGR=? OK
Response
1)If text mode (AT+CMGF=1), command successful and SMS-
DELIVER:
+CMGR:
<stat>,<oa>,[<alpha>],<scts>[,<tooa>,<fo>,<pid>,<dcs>,<sca>,
<tosca>,<length>]
<data>

OK
2)If text mode (AT+CMGF=1), command successful and SMS-
SUBMIT:
+CMGR:
<stat>,<da>,[<alpha>][,<toda>,<fo>,<pid>,<dcs>,[<vp>],<sca>,<
tosca>,<length>]
<data>

OK
3)If text mode (AT+CMGF=1), command successful and SMS-
STATUS-REPORT:
+CMGR: <stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st>
Write Command
AT+CMGR=<index>
OK
If text mode (AT+CMGF=1), command successful and SMS-
COMMAND:
+CMGR:
<stat>,<fo>,<ct>[,<pid>,[<mn>],[<da>],[<toda>],<length>]<CR>
<LF><data>

OK
4)If text mode (AT+CMGF=1), command successful and CBM
storage:
+CMGR:
<stat>,<sn>,<mid>,<dcs>,<page>,<pages><CR><LF><data>

OK
5)If PDU mode (AT+CMGF=0)and Command successful:
+CMGR: <stat>,[<alpha>],<length><CR><LF><pdu>

OK
6)
+CMS ERROR: <err>

www.simcom.com 218 / 483


A76XX Series_AT Command Manual_V1.04

Parameter Saving Mode NO_SAVE


Max Response Time 9000ms
Reference 3GPP TS 27.005

Defined Values

<index> Integer type; value in the range of location numbers supported by


the associated memory and start with one.
<stat> 1. Text Mode:
"REC UNREAD" received unread message (i.e. new message)
"REC READ" received read message
"STO UNSENT" stored unsent message
"STO SENT" stored sent message
2. PDU Mode:
0 received unread message (i.e. new message)
1 received read message
2 stored unsent message
3 stored sent message
<oa> Originating-Address, Address-Value field in string format; BCD
numbers (or GSM 7 bit default alphabet characters)are converted
to characters of the currently selected TE character set, type of
address given by <tooa>.
<alpha> String type alphanumeric representation of <da> or <oa>
corresponding to the entry found in MT phonebook;
implementation of this feature is manufacturer specific; used
character set should be the one selected with command Select TE
Character Set AT+CSCS.
<scts> TP-Service-Centre-Time-Stamp in time-string format (refer <dt>).
<tooa> TP-Originating-Address, Type-of-Address octet in integer format.
(default refer <toda>).
<fo> Depending on the command or result code: first octet of GSM
03.40 SMS-DELIVER, SMS-SUBMIT (default 17),
SMS-STATUS-REPORT, or SMS-COMMAND (default 2)in integer
format. SMS status report is supported under text mode if <fo> is
set to 49.
<pid> Protocol Identifier
GSM 03.40 TP-Protocol-Identifier in integer format
0…255
<dcs> Depending on the command or result code: SMS Data Coding
Scheme (default 0), or Cell Broadcast Data Coding Scheme in
integer format.
<sca> RP SC address Address-Value field in string format; BCD numbers
(or GSM 7 bit default alphabet characters)are converted to
characters of the currently selected TE character set, type of

www.simcom.com 219 / 483


A76XX Series_AT Command Manual_V1.04

address given by <tosca>.


<tosca> RP SC address Type-of-Address octet in integer format (default
refer <toda>).
<length> Integer type value indicating in the text mode (AT+CMGF=1)the
length of the message body <data> in characters; or in PDU mode
(AT+CMGF=0), the length of the actual TP data unit in octets. (i.e.
the RP layer SMSC address octets are not counted in the length)
<data> In the case of SMS: TP-User-Data in text mode responses; format:
1. If <dcs> indicates that GSM 7 bit default alphabet is used and
<fo> indicates that TP-User-Data-Header-Indication is not set:
a. If TE character set other than "HEX": ME/TA converts GSM
alphabet into current TE character set.
b. If TE character set is "HEX": ME/TA converts each 7-bit
character of GSM 7 bit default alphabet into two IRA character long
hexadecimal numbers. (e.g. character (GSM 7 bit default alphabet
23)is presented as 17 (IRA 49 and 55))
2. If <dcs> indicates that 8-bit or UCS2 data coding scheme is
used, or <fo> indicates that TP-User-Data-Header-Indication is
set: ME/TA converts each 8-bit octet into two IRA character long
hexadecimal numbers. (e.g. octet with integer value 42 is
presented to TE as two characters 2A (IRA 50 and 65))
3. If <dcs> indicates that GSM 7 bit default alphabet is used:
a. If TE character set other than "HEX": ME/TA converts GSM
alphabet into current TE character set.
b. If TE character set is "HEX": ME/TA converts each 7-bit
character of the GSM 7 bit default alphabet into two IRA character
long hexadecimal numbers.
4. If <dcs> indicates that 8-bit or UCS2 data coding scheme is
used: ME/TA converts each 8-bit octet into two IRA character long
hexadecimal numbers.
<da> Destination-Address, Address-Value field in string format; BCD
numbers (or GSM 7 bit default alphabet characters)are converted
to characters of the currently selected TE character set, type of
address given by <toda>.
<toda> TP-Destination-Address, Type-of-Address octet in integer format.
(when first character of <da> is + (IRA 43)default is 145, otherwise
default is 129). The range of value is from 128 to 255.
<vp> Depending on SMS-SUBMIT <fo> setting: TP-Validity-Period
either in integer format (default 167)or in time-string format (refer
<dt>).
<mr> Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<ra> Recipient Address
GSM 03.40 TP-Recipient-Address Address-Value field in string
format; BCD numbers (or GSM default alphabet characters)are

www.simcom.com 220 / 483


A76XX Series_AT Command Manual_V1.04

converted to characters of the currently selected TE character


set(refer to command AT+CSCS);type of address given by <tora>
<tora> Type of Recipient Address
GSM 04.11 TP-Recipient-Address Type-of-Address octet in integer
format (default refer <toda>)
<dt> Discharge Time
GSM 03.40 TP-Discharge-Time in time-string
format:"yy/MM/dd,hh:mm:ss+zz",where characters indicate year
(two last digits),month,day,hour,minutes,seconds and time zone.
<st> Status
GSM 03.40 TP-Status in integer format
0…255
<ct> Command Type
GSM 03.40 TP-Command-Type in integer format
0…255
<mn> Message Number
GSM 03.40 TP-Message-Number in integer format
<sn> Serial Number
GSM 03.41 CBM Serial Number in integer format
<mid> Message Identifier
GSM 03.41 CBM Message Identifier in integer format
<page> Page Parameter
GSM 03.41 CBM Page Parameter bits 4-7 in integer format
<pages> Page parameter
GSM 03.41 CBM Page Parameter bits 0-3 in integer format
<pdu> In the case of SMS: SC address followed by TPDU in hexadecimal
format: ME/TA converts each octet of TP data unit into two IRA
character long hexadecimal numbers. (eg. octet with integer value
42 is presented to TE as two characters 2A (IRA 50 and 65)).

Examples

AT+CMGR=?
OK
AT+CMGR=1
+CMGR: "STO UNSENT","+10011",,145,17,0,0,167,"+8613800100500",145,11
Hello World

OK

www.simcom.com 221 / 483


A76XX Series_AT Command Manual_V1.04

AT+CMGS Send message

This command is used to send message from a TE to the network (SMS-SUBMIT).

AT+CMGS Send message


Test Command Response
AT+CMGS=? OK
Response
Write Command
1)If sending successfully:
If text mode(AT+CMGF=1)
+CMGS: <mr>
AT+CMGS=<da>[,<toda>]
Text is entered.
OK
<CTRL-Z/ESC>
2)If cancel sending:
If PDU mode(AT+CMGF=0)
OK
AT+CMGS=<length>
3)If sending fails
PDU is entered
ERROR
<CTRL-Z/ESC>
4)If sending fails:
+CMS ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 40s
Reference 3GPP TS 27.005

Defined Values

<da> Destination-Address, Address-Value field in string format; BCD


numbers (or GSM 7 bit default alphabet characters)are converted
to characters of the currently selected TE character set, type of
address given by <toda>.
<toda> TP-Destination-Address, Type-of-Address octet in integer format.
(when first character of <da> is + (IRA 43)default is 145,
otherwise default is 129). The range of value is from 128 to 255.
<length> integer type value indicating in the text mode (AT+CMGF=1)the
length of the message body <data> > (or <cdata>)in characters;
or in PDU mode (AT+CMGF=0), the length of the actual TP data
unit in octets. (i.e. the RP layer SMSC address octets are not
counted in the length)
<mr> Message Reference
GSM 03.40 TP-Message-Reference in integer format.

Examples

www.simcom.com 222 / 483


A76XX Series_AT Command Manual_V1.04

AT+CMGS=?
OK //TEXT MODE
AT+CMGS="13012832788"
>ABCD<ctrl-Z/ESC>
+CMGS: 46

OK

NOTE

In text mode, the maximum length of an SMS depends on the used coding scheme: It is 160 characters if
the 7 bit GSM coding scheme is used.

AT+CMSS Send message from storage

This command is used to send message with location value <index> from preferred message storage
<mem2> to the network (SMS-SUBMIT or SMS-COMMAND).

AT+CMSS Send message from storage


Test Command Response
AT+CMSS=? OK
Response
1)
+CMSS: <mr>
Write Command
AT+CMSS=<index>[,<da>[,<tod OK
a>]] 2)
ERROR
3)If sending fails:
+CMS ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.005

Defined Values

<index> Integer type; value in the range of location numbers supported by


the associated memory and start with one.

www.simcom.com 223 / 483


A76XX Series_AT Command Manual_V1.04

<da> Destination-Address, Address-Value field in string format; BCD


numbers (or GSM 7 bit default alphabet characters)are converted
to characters of the currently selected TE character set, type of
address given by <toda>.
<mr> Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<toda> TP-Destination-Address, Type-of-Address octet in integer format.
(when first character of <da> is + (IRA 43)default is 145,
otherwise default is 129). The range of value is from 128 to 255.

Examples

AT+CMSS=?
OK
AT+CMSS=3
+CMSS: 0

OK
AT+CMSS=3,"13012345678"
+CMSS: 55

OK

NOTE
NOTE

In text mode, the maximum length of an SMS depends on the used coding scheme: It is 160 characters if
the 7 bit GSM coding scheme is used.

AT+CMGW Write message to memory

This command is used to store message (either SMS-DELIVER or SMS-SUBMIT)to memory storage
<mem2>.

AT+CMGW Write message to memory


Test Command Response
AT+CMGW=? OK
Write Command Response
If text mode(AT+CMGF=1) 1)If write successfully:
AT+CMGW=<oa>/<da>[,<tooa>/ +CMGW: <index>

www.simcom.com 224 / 483


A76XX Series_AT Command Manual_V1.04

<toda>[,<stat>]]
Text is entered. OK
<CTRL-Z/ESC> 2)If write fails:
If PDU mode(AT+CMGF=0): ERROR
AT+CMGW=<length>[,<stat>] 3)If write fails:
PDU is entered. +CMS ERROR: <err>
<CTRL-Z/ESC>
Parameter Saving Mode NO_SAVE
Max Response Time 40s
Reference 3GPP TS 27.005

Defined Values

<index> Integer type; value in the range of location numbers supported by


the associated memory and start with one.
<oa> Originating-Address, Address-Value field in string format; BCD
numbers (or GSM 7 bit default alphabet characters)are converted
to characters of the currently selected TE character set, type of
address given by <tooa>.
<tooa> TP-Originating-Address, Type-of-Address octet in integer format.
(default refer <toda>).
<da> Destination-Address, Address-Value field in string format; BCD
numbers (or GSM 7 bit default alphabet characters)are converted
to characters of the currently selected TE character set, type of
address given by <toda>.
<toda> TP-Destination-Address, Type-of-Address octet in integer format.
(when first character of <da> is + (IRA 43)default is 145,
otherwise default is 129). The range of value is from 128 to 255.
<length> Integer type value indicating in the text mode (AT+CMGF=1)the
length of the message body <data> > (or <cdata>)in characters;
or in PDU mode (AT+CMGF=0), the length of the actual TP data
unit in octets. (i.e. the RP layer SMSC address octets are not
counted in the length).
<stat> 1 Text Mode:
"STO UNSENT" stored unsent message
"STO SENT" stored sent message
2 PDU Mode:
2 stored unsent message
3 stored sent message

Examples

AT+CMGW=? //TEXT MODE

www.simcom.com 225 / 483


A76XX Series_AT Command Manual_V1.04

OK
AT+CMGW="13012832788"
>ABCD<ctrl-Z/ESC>
+CMGW: 1

OK

NOTE

In text mode, the maximum length of an SMS depends on the used coding scheme: It is 160 characters if
the 7 bit GSM coding scheme is used.

AT+CMGD Delete message

This command is used to delete message from preferred message storage <mem1> location <index>. If
<delflag> is present and not set to 0 then the ME shall ignore <index> and follow the rules for <delflag>
shown below.

AT+CMGD Delete message


Test Command Response
AT+CMGD=? +CMGD: (index),(delflag)

OK
Response
1)
OK
Write Command
2)
AT+CMGD=<index>[,<delflag>]
ERROR
3)
+CMS ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.005

Defined Values

<index> Integer type; value in the range of location numbers supported by


the associated memory and start with one.

www.simcom.com 226 / 483


A76XX Series_AT Command Manual_V1.04

<delflag> 0 (or omitted)Delete the message specified in <index>.


1 Delete all read messages from preferred message
storage, leaving unread messages and stored mobile
originated messages (whether sent or not)untouched.
2 Delete all read messages from preferred message
storage and sent mobile originated messages,
leaving unread messages and unsent mobile
originated messages untouched.
3 Delete all read messages from preferred message
storage, sent and unsent mobile originated messages
leaving unread messages untouched.
4 Delete all messages from preferred message storage
including unread messages.

Examples

AT+CMGD=?
+CMGD: (1),(0-4)

OK
AT+CMGD=1
OK

NOTE

If set <delflag>=1, 2, 3 or 4, <index> is omitted, such as AT+CMGD=,1.

AT+CMGMT Change message status

This command is used to change the message status. If the status is unread, it will be changed read. Other
statuses don’t change.

AT+CMGMT Change message status


Test Command Response
AT+CMGMT=? OK
Write Command Response
AT+CMGMT=<index> 1)

www.simcom.com 227 / 483


A76XX Series_AT Command Manual_V1.04

OK
2)
ERROR
3)
+CMS ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.005

Defined Values

<index> Integer type; value in the range of location numbers supported by the
associated memory and start with one.

Examples

AT+CMGMT=?
OK
AT+CMGMT=1
OK

AT+CMVP Set message valid period

This command is used to set valid period for sending short message.

AT+CMVP Set message valid period


Test Command Response
AT+CMVP=? +CMVP: (list of supported <vp>s)

OK
Read Command Response
AT+CMVP? +CMVP: <vp>

OK
Response
Write Command 1)
AT+CMVP=<vp> OK
2)

www.simcom.com 228 / 483


A76XX Series_AT Command Manual_V1.04

ERROR
3)
+CMS ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference 3GPP TS 27.005

Defined Values

<vp> Validity period value:


0 to 143 (<vp>+1)x 5 minutes (up to 12 hours)
144 to 167 12 hours + (<vp>-143)x 30 minutes
168 to 196 (<vp>-166)x 1 day
197 to 255 (<vp>-192)x 1 week

Examples

AT+CMVP=?
+CMVP: (0-255)

OK
AT+CMVP=167
OK
AT+CMVP?
+CMVP: 167

OK

AT+CMGRD Read and delete message

This command is used to read message, and delete the message at the same time. It integrate AT+CMGR
and AT+CMGD, but it doesn’t change the message status.

AT+CMGRD Read and delete message


Test Command Response
AT+CMGRD=? OK
Write Command Response
AT+CMGRD=<index> 1)If text mode(AT+CMGF=1),command successful and

www.simcom.com 229 / 483


A76XX Series_AT Command Manual_V1.04

SMS-DE-LIVER:
+CMGRD:
<stat>,<oa>,[<alpha>],<scts>[,<tooa>,<fo>,<pid>,<dcs>,<sca>,
<tosca>,<length>]
<data>

OK
2)If text mode(AT+CMGF=1),command successful and SMS-SU-
BMIT:
+CMGRD:
<stat>,<da>,[<alpha>][,<toda>,<fo>,<pid>,<dcs>,[<vp>],<sca>,<
tosca>,<length>]
<data>

OK
3)If text mode(AT+CMGF=1),command successful and SMS-STA-
TUS- REPORT:
+CMGRD: <stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st>

OK
4)If text mode(AT+CMGF=1),command successful and
SMS-CO-MMAND:
+CMGRD:
<stat>,<fo>,<ct>[,<pid>,[<mn>],[<da>],[<toda>],<length>
<data>]

OK
5)If text mode(AT+CMGF=1),command successful and CBM sto-
rage:
+CMGRD: <stat>,<sn>,<mid>,<dcs>,<page>,<pages>
<data>

OK
6)If PDU mode(AT+CMGF=0)and command successful:
+CMGRD: <stat>,[<alpha>],<length>
<pdu>

OK
7)
ERROR
8)
+CMS ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 40s
Reference 3GPP TS 27.005
www.simcom.com 230 / 483
A76XX Series_AT Command Manual_V1.04

Defined Values

Refer to command AT+CMGR.

Examples

AT+CMGRD=?
OK
AT+CMGRD=6
+CMGRD: "REC
READ","+8613917787249",,"06/07/10,12:09:
38+32",145,4,0,0, "+86138002105 00",145,4
How do you do

OK

AT+CMGSEX Send message

This command is used to send message from a TE to the network (SMS-SUBMIT).

AT+CMGSEX Send message


Test Command Response
AT+CMGSEX=? OK
Response
1)
Write Command
+CMGSEX: <mr>
If text mode(AT+CMGF=1):
AT+CMGSEX=<da>[,<toda>][,<
OK
mr>,<msg_seg>,<msg_total>]
2)
Text is entered.
ERROR
<CTRL-Z/ESC>
3)
+CMS ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 40s
Reference 3GPP TS 27.005

www.simcom.com 231 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<da> Destination-Address, Address-Value field in string format; BCD


numbers (or GSM 7 bit default alphabet characters)are converted
to characters of the currently selected TE character set, type of
address given by <toda>.
<toda> TP-Destination-Address, Type-of-Address octet in integer format.
(When first character of <da> is + (IRA 43)default is 145,
otherwise default is 129). The range of value is from 128 to 255.
<mr> Message Reference GSM 03.40 TP-Message-Reference in
integer format. The range of value is from1to 255.
<msg_seg> The segment number for long sms
<msg_total> The segment number for long sms, max value is 15.

Examples

AT+CMGSEX=?
OK //TEXT MODE
AT+CMGSEX="13012832788",190,1,2
> ABCD<ctrl-Z/ESC>
+CMGSEX: 190

OK
AT+CMGSEX="13012832788",190,2,2 //TEXT MODE
> EFGH<ctrl-Z/ESC>
+CMGSEX: 190

OK

NOTE

In text mode, the maximum length of an SMS depends on the used coding scheme: For single SMS, it is
160 characters if the 7 bit GSM coding scheme is used; For multiple long sms, it is 153 characters if the 7
bit GSM coding scheme is used.

AT+CMSSEX Send multi messages from storage

This command is used to send messages with location value <index1>,<index2>,<index3>… from

www.simcom.com 232 / 483


A76XX Series_AT Command Manual_V1.04

preferred message storage <mem2> to the network (SMS-SUBMIT or SMS-COMMAND).The max count of
index is 13 one time.

AT+CMSSEX Send multi messages from storage


Test Command Response
AT+CMSSEX=? OK
Response
1)
[+CMSSEX: <mr>[,<mr>[,…]]]

Write Command
OK
AT+CMSSEX=<index>[,<index>[
2)
,… ]]
ERROR
3)If sending fails:
[+CMSSEX: <mr>[,<mr>[,…]]]
+CMS ERROR: <err>
Parameter Saving Mode NO_SAVE
Max Response Time 40s
Reference 3GPP TS 27.005

Defined Values

<index> Integer type; value in the range of location numbers supported by


the associated memory and start with one.
<mr> Message Reference

Examples

AT+CMSSEX=?
OK
AT+CMSSEX=1,2
+CMSSEX: 239,240

OK
AT+CMSSEX=1,2
+CMSSEX: 238
+CMS ERROR: Invalid memory index

NOTE

In text mode, the maximum length of an SMS depends on the used coding scheme: For single SMS, it is

www.simcom.com 233 / 483


A76XX Series_AT Command Manual_V1.04

160 characters if the 7 bit GSM coding scheme is used.

www.simcom.com 234 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for Serial Interface


Overview of AT Commands for Serial Interface

Command Description
AT&D Set DTR function mode
AT&C Set DCD function mode
AT+IPR Set local baud rate temporarily
AT+IPREX Set local baud rate permanently
AT+ICF Set control character framing
AT+IFC Set local data flow control
AT+CSCLK Control UART Sleep
AT+CMUX Enable the multiplexer over the UART
AT+CATR Configure URC destination interface
AT+CFGRI Configure RI pin
AT+CURCD Configure the delay time and number of URC

Detailed Description of AT Commands for Serial Interface

AT&D Set DTR function mode

This command determines how the TA responds when DTR PIN is changed from the ON to the OFF
condition during data mode.

AT&D Set DTR function mode


Response
1)
Execution Command
OK
AT&D[<value>]
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
www.simcom.com 235 / 483
A76XX Series_AT Command Manual_V1.04

Reference -

Defined Values

<value> 0 TA ignores status on DTR.


1 ON->OFF on DTR: Change to Command mode with remaining the
connected call.
2 ON->OFF on DTR: Disconnect call, change to Command
mode.During state DTR=OFF is auto-answer off.

Examples

AT&D1
OK

AT&C Set DCD function mode

This command determines how the state of DCD PIN relates to the detection of received line signal from the
distant end.

AT&C Set DCD function mode


Response
1)
Execution Command
OK
AT&C[<value>]
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<value> 0 DCD line shall always be on.


1 DCD line shall be on only when data carrier signal is present.
2 Setting the DCD line be on just 1 second after the data calls end.

Examples

www.simcom.com 236 / 483


A76XX Series_AT Command Manual_V1.04

AT&C1
OK

AT+IPR Set local baud rate temporarily

This command sets the baud rate of module’s serial interface temporarily, after reboot the baud rate is set to
value of IPREX.

AT+IPR Set local baud rate temporarily


Response
Test Command +IPR: (list of supported <speed>s)
AT+IPR=?
OK
Response
Read Command +IPR: <speed>
AT+IPR?
OK
Response
1)
Write Command
OK
AT+IPR=<speed>
2)
ERROR
Response
Execution Command
Set the value to boot value:
AT+IPR
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<speed> Baud rate per second:


300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200,
230400, 460800, 921600, 1842000, 3686400.

Examples

AT+IPR?
+IPR: 115200

www.simcom.com 237 / 483


A76XX Series_AT Command Manual_V1.04

OK
AT+IPR=?
+IPR:
(300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400,460800,921600,1842000,3686400
)

OK
AT+IPR=115200
OK

AT+IPREX Set local baud rate permanently

This command sets the baud rate of module’s serial interface permanently, after reboot the baud rate is also
valid.

AT+IPREX Set local baud rate permanently


Response
Test Command +IPREX: (list of supported <speed>s)
AT+IPREX=?
OK
Response
Read Command +IPREX: <speed>
AT+IPREX?
OK
Response
1)
Write Command
OK
AT+IPREX=<speed>
2)
ERROR
Response
Execution Command
Set default value 115200:
AT+IPREX
OK
Parameter Saving Mode AUTO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<speed> Baud rate per second:


300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200,
230400, 460800, 921600, 1842000, 3686400.
www.simcom.com 238 / 483
A76XX Series_AT Command Manual_V1.04

Examples

AT+IPREX?
+IPREX: 115200

OK
AT+IPREX=?
+IPREX: (300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400,460800,921600,
1842000,3686400)

OK
AT+IPREX=115200
OK

AT+ICF Set control character framing

This command sets character framing which contains data bit, stop bit and parity bit.

AT+ICF Set control character framing


Response
Test Command +ICF: (list of supported<format>s),(list of supported<parity>s)
AT+ICF=?
OK
Response
Read Command +ICF: <format>,<parity>
AT+ICF?
OK
Response
1)
Write Command
OK
AT+ICF=<format>[,<parity>]
2)
ERROR
Response
Execution Command
Set default value:
AT+ICF
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

www.simcom.com 239 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<format> 1 data bit 8, parity bit 1,stop bit 1.


2 data bit 8, stop bit 1.
3 data bit 7, parity bit 1,stop bit 1.
4 data bit 7, stop bit 1.
<parity> 0 Odd
1 Even
2 none

Examples

AT+ICF?
+ICF: 2,2

OK
AT+ICF=?
+ICF: (1-4),(0-2)

OK
AT+ICF=2,2
OK
AT+ICF
OK

AT+IFC Set local data flow control

The command sets the flow control mode of the module. A7600X(X)-MNSE does not support flow control
function.

AT+IFC Set local data flow control


Response
Test Command +IFC: (list of supported<DCE>s),(list of supported<DTE>s)
AT+IFC=?
OK
Response
Read Command +IFC: <DCE>,<DTE>
AT+IFC?
OK
Write Command Response
AT+IFC=<DCE>[,<DTE>] 1)
www.simcom.com 240 / 483
A76XX Series_AT Command Manual_V1.04

OK
2)
ERROR
Response
Execution Command
Set default value:
AT+IFC
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<DCE> 0 none
2 RTS hardware flow control
<DTE> 0 none
2 CTS hardware flow control

Examples

AT+IFC?
+ICF: 0,0

OK
AT+IFC=?
+IFC: (0,2),(0,2)

OK
AT+IFC=2,2
OK
AT+IFC
OK

AT+CSCLK Control UART Sleep

This command is used to enable UART Sleep or always work. If set to 0, UART always work. If set to 1,
ensure that DTR is pulled high and the module can go to DTR sleep. If set to 2, the module will enter RX
sleep. RX wakeup directly sends data through the serial port (for example: AT) to wake up.

AT+CSCLK Control UART Sleep


Test Command Response
AT+CSCLK=? +CSCLK: (range of supported <status>s)
www.simcom.com 241 / 483
A76XX Series_AT Command Manual_V1.04

OK
Response
Read Command +CSCLK: <status>
AT+CSCLK?
OK
Response
1)
Write Command
OK
AT+CSCLK=<status>
2)
ERROR
Response
Execution Command
Set <status>=0:
AT+CSCLK
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<status> 0 off
1 DTR sleep
2 RX sleep

Examples

AT+CSCLK?
+CSCLK: 0

OK
AT+CSCLK=?
+CSCLK: (0-2)

OK
AT+CSCLK=1
OK
AT+CSCLK=2
OK
AT+CSCLK
OK

www.simcom.com 242 / 483


A76XX Series_AT Command Manual_V1.04

AT+CMUX Enable the multiplexer over the UART

This command is used to enable the multiplexer over the UART, after enabled four virtual ports can be used
as AT command port or MODEM port, the physical UART can no longer transfer data directly under this
case. By default all of the four virtual ports are used as AT command port. Second serial port is not support
this command.

AT+CMUX Enable the multiplexer over the UART


Response
Test Command +CMUX: (0),(0),(1-8),(1-1500),(0),(0),(2-1000)
AT+CMUX=?
OK
Response
Read Command +CMUX: <value>,<subset>,<port_speed>,<N1>,<T1>,<N2>,<T2>
AT+CMUX?
OK
Response
Write Command
1)
AT+CMUX=<value>[,<subset
OK
>[,<port_speed>[,<N1>[,<T1
2)
>[,<N2>[,<T2>]]]]]]
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<value> 0 currently only 0 is supported (basic operation mode).


<subset> Currently omitted
<port_speed> Currently omitted, you can set speed before enable multiplexer
<N1> 1-1500
<T1> Currently omitted
<N2> Currently omitted
<T2> 2-1000

Examples

AT+CMUX?
+CMUX: 0,0,5,1500,0,0,600

OK

www.simcom.com 243 / 483


A76XX Series_AT Command Manual_V1.04

AT+CMUX=?
+CMUX: (0),(0),(1-8),(1-1500),(0),(0),(2-1000)

OK
AT+CMUX=0
OK

AT+CATR Configure URC destination interface

This command is used to configure the serial port which will be used to output URCs. We recommend
configure a destination port for receiving URC in the system initialization phase, in particular, in the case
that transmitting large amounts of data, e.g. use TCP/UDP and MT SMS related AT command.

AT+CATR Configure URC destination interface


Response
Test Command +CATR: (list of supported <port>s)
AT+CATR=?
OK
Response
Read Command +CATR: <port>
AT+CATR?
OK
Response
1)
Write Command
OK
AT+CATR=<port>
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<port> 0 all ports


1 use UART port to output URCs
2 use MODEM port to output URCs
3 use ATCOM port to output URCs
4 use cmux virtual port1 to output URCs
5 use cmux virtual port2 to output URCs
6 use cmux virtual port3 to output URCs
7 use cmux virtual port4 to output URCs

www.simcom.com 244 / 483


A76XX Series_AT Command Manual_V1.04

Examples

AT+CATR?
+CATR: 0

OK
AT+CATR=?
+CATR: (0-7)

OK
AT+CATR=1
OK

AT+CFGRI Configure RI pin

This command configures the time of pulling RI down. These places are going to use it, for Examples:
SMS, FTP, NETWORK, PB, CM, OS and so on.

AT+CFGRI Configure RI pin


Response
+CFGRI: (list of supported<status>),(list of
Test Command
supported<URC_time>ms), (list of supported<SMS_time>ms)
AT+CFGRI=?

OK
Response
Read Command +CFGRI: <status>,<URC_time>,<SMS_time>
AT+CFGRI?
OK
Response
Write Command 1)
AT+CFGRI=<status>[,<time1 OK
>[,<time2>]] 2)
ERROR
Response
Execution Command
Set default value:
AT+CFGRI
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

www.simcom.com 245 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<status> 0 off.
1 on.
<URC_time> a numeric parameter which is number of milliseconds to assert RI
delay to reset RI. The range is 10 to 6000, default value is 60ms.
<SMS_time> a numeric parameter which is number of milliseconds to assert RI
delay to reset RI. The range is 20 to 6000, default value is 120ms.

Examples

AT+CFGRI?
+CFGRI: 0,60,120

OK
AT+CFGRI=?
+CFGRI: (0-1),(10-6000),(20-6000)

OK
AT+CFGRI=0,60,120
OK
AT+CFGRI
OK

AT+CURCD Configure the delay time and number of URC

This command is used to configure delay time when output URC and the number of cached URCs. You can
control delay time if some URC supports delay output. You can also set size to store URCs, they will output
together when the delay time ends. For Examples, if you set delay time to 10ms and set the number of
cached URCs to 1, there is only one URC output after 10ms.

AT+CURCD Configure the delay time and number of URC


Response
Test Command +CURCD: (range of supported <delay_time>ms),(1)
AT+CURCD=?
OK
Response
Read Command +CURCD: <delay_time>,1
AT+CURCD?
OK

www.simcom.com 246 / 483


A76XX Series_AT Command Manual_V1.04

Response
Write Command 1)
AT+CURCD=<delay_time>,< OK
cache_size> 2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<delay_time> 0-10000 the unit is ms


<cache_size> 1 currently only 1 is supported

Examples

AT+CURCD?
+CURCD: 0,1

OK
AT+CURCD=?
+CURCD: (0-10000),(1)

OK
AT+CURCD=100,1
OK

NOTE

Currently only support delay time setting, the default cache size for URC is one. This command applies
to platform 1601 related projects, such as A7600E, A7600C-C1SE etc.

www.simcom.com 247 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for Hardware


Overview of AT Commands for Hardware

Command Description
AT+CVALARM Low and high voltage Alarm
AT+CVAUXS Set state of the pin named VDD_AUX
AT+CVAUXV Set voltage value of the pin named VDD_AUX
AT+CADC Read ADC value
AT+CADC2 Read ADC2 value
AT+CMTE Control the module critical temperature URC alarm
AT+CPMVT Low and high voltage Power Off
AT+CRIIC Read values from register of IIC device nau8810
AT+CWIIC Write values to register of IIC device nau8810
AT+CBC Read the voltage value of the power supply
AT+CPMUTEMP Read the temperature of the module
AT+CGDRT Set the direction of specified GPIO
AT+CGSETV Set the value of specified GPIO
AT+CGGETV Get the value of specified GPIO

Detailed Description of AT Commands for Hardware

AT+CVALARM Low and high voltage Alarm

This command is used to open or close the low voltage alarm function.

AT+CVALARM Low and high voltage Alarm


Response
Test Command +CVALARM: (list of supported <enable>s),(list of supported <low
AT+CVALARM=? voltage>s),(list of supported <high voltage>s)

www.simcom.com 248 / 483


A76XX Series_AT Command Manual_V1.04

OK
Response
Read Command +CVALARM: <enable>,<low voltage>,<high voltage>
AT+CVALARM?
OK
Response
Write Command
1)
AT+CVALARM=<enable>[,<l
OK
ow voltage>],[<high
2)
voltage>]
ERROR
Parameter Saving Mode AUTO_SAVE
Max Response Time -
Reference -

Defined Values

<enable> 0 Close
1 Open. If voltage less than <low voltage>, it will report
"UNDER-VOLTAGE WARNNING" every 10s. If voltage greater than
<high voltage>, it will report "OVER-VOLTAGE WARNNING" every
10s.
<low voltage> Between 3300mV and 4000mV. Default value is 3300.
<high voltage> Between 4001mV and 4300mV. Default value is 4300.

Examples

AT+CVALARM=1,3400,4300
OK
AT+CVALARM?
+CVALARM: 1,3400,4300

OK
AT+CVALARM=?
+CVALARM: (0,1),(3300-4000),(4001-4300)

OK

AT+CVAUXS Set state of the pin named VDD_AUX

This command is used to set state of the pin which is named VDD_AUX.
www.simcom.com 249 / 483
A76XX Series_AT Command Manual_V1.04

AT+CVAUXS Set state of the pin named VDD_AUX


Response
1)
Test Command
+CVAUXS: (list of supported <state>s)
AT+CVAUXS=?

OK
Response
Read Command +CVAUXS: <state>
AT+CVAUXS?
OK
Response
1)
Write Command
OK
AT+CVAUXS=<state>
2)
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<state> 0 output of the pin disabled.


1 output of the pin enabled.

Examples

AT+CVAUXS=?
+CVAUXS: (0,1)

OK
AT+CVAUXS=1
OK
AT+CVAUXS?
+CVAUXS: 1

OK

AT+CVAUXV Set voltage value of the pin named VDD_AUX

www.simcom.com 250 / 483


A76XX Series_AT Command Manual_V1.04

This command is used to set the voltage value of the pin which is named VDD_AUX.

AT+CVAUXV Set voltage value of the pin named VDD_AUX


Response
Test Command +CVAUXV: (list of supported <voltage>s)
AT+CVAUXV=?
OK
Response
Read Command +CVAUXV: <voltage>
AT+CVAUXV?
OK
Response
1)
Write Command
OK
AT+CVAUXV=<voltage>
2)
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<voltage> Voltage value of the pin which is named VDD_AUX. The unit is in mv.

Examples

AT+CVAUXV=?
+CVAUXV:
(1200,1250,1700,1800,1850,1900,2500,2600,2700,2750,2800,2850,2900,3000,3100,3300)

OK
AT+CVAUXV=3000
OK
AT+CVAUXV?
+CVAUXV: 3000

OK

AT+CADC Read ADC value

www.simcom.com 251 / 483


A76XX Series_AT Command Manual_V1.04

This command is used to read the ADC value from modem. ME supports 2 types of ADC, which are raw
type and voltage type.

AT+CADC Read ADC value


Response
Test Command +CADC: (range of supported <adc>s)
AT+CADC=?
OK
Response
1)
+CADC: <value>
Write Command
AT+CADC=<adc>
OK
2)
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<adc> ADC type:


0 raw type.
2 voltage type(mv).
<value> Integer type value of the ADC.

Examples

AT+CADC=?
+CADC: (0,2)

OK
AT+CADC=2
+CADC: 908

OK

AT+CADC2 Read ADC2 value

This command is used to read the ADC2 value from modem. ME supports 2 types of ADC, which are raw
www.simcom.com 252 / 483
A76XX Series_AT Command Manual_V1.04

type and voltage type.

AT+CADC2 Read ADC2 value


Response
Test Command +CADC2: (range of supported <adc>s)
AT+CADC2=?
OK
Response
1)
+CADC2: <value>
Write Command
AT+CADC2=<adc>
OK
2)
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<adc> ADC2 type:


0 raw type.
2 voltage type(mv)
<value> Integer type value of the ADC2.

Examples

AT+CADC2=?
+CADC2: (0,2)

OK
AT+CADC2=2
+CADC2: 904

OK

AT+CMTE Control the module critical temperature URC alarm

This command is used to control the module whether URC alarm when the module’s temperature upon the
critical temperature.
www.simcom.com 253 / 483
A76XX Series_AT Command Manual_V1.04

AT+CMTE Control the module critical temperature URC alarm


Response
Test Command
+CMTE: (list of supported<on/off>s)
AT+CMTE=?

OK
Response
Read Command +CMTE: <on/off>
AT+CMTE?
OK
Response
1)
Write Command
OK
AT+CMTE=<on/off>
2)
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<on/off> 0 Disable temperature detection


1 Enable temperature detection

Examples

AT+CMTE=?
+CMTE: (0,1)

OK
AT+CMTE=1
OK
AT+CMTE?
+CMTE: 1

OK

AT+CPMVT Low and high voltage Power Off

This command is used to open or close the low and high voltage power off function and set the threshold of

www.simcom.com 254 / 483


A76XX Series_AT Command Manual_V1.04

power off voltage.

AT+CPMVT Low and high voltage Power Off


Response
+CPMVT: (list of supported <enable>s),(list of supported <low
Test Command
voltage>s),(list of supported <high voltage>s)
AT+CPMVT=?

OK
Response
Read Command +CPMVT: <enable>,<low voltage>,<high voltage>
AT+CPMVT?
OK
Response
Write Command 1)
AT+CPMVT=<enable>[,<low OK
voltage>],[<high voltage>] 2)
ERROR
Parameter Saving Mode AUTO_SAVE
Max Response Time -
Reference -

Defined Values

<enable> 0 Close. 0 is the default value


1 Open. If voltage less than <low voltage>, it will report
"UNDER-VOLTAGE WARNNING POWER DOWN" and power off the
module. If voltage greater than <high voltage>, it will report
"OVER-VOLTAGE WARNNING POWER DOWN" and power off the
module
<low voltage> Between 3300mV and 4000mV. Default value is 3300.
<high voltage> Between 4001mV and 4300mV. Default value is 4300.

Examples

AT+CPMVT=1,3400,4300
OK
AT+CPMVT?
+CPMVT: 1,3400,4300

OK
AT+CPMVT=?
www.simcom.com 255 / 483
A76XX Series_AT Command Manual_V1.04

+CPMVT: (0,1),(3300-4000),(4001-4300)

OK

AT+CRIIC Read values from register of IIC device nau8810

This command is used to read values from register of IIC device nau8810.

AT+CRIIC Read values from register of IIC device nau8810


Test Command Response
AT+CRIIC=? OK
Response
1)
Write Command +CRIIC: <data>
AT+CRIIC=<addr>,<reg>,<le
n> OK
2)
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<addr> Device address. Input format must be hex, such as FF (do not input
"0x").
<reg> Register address. Input format must be hex, such as FF (do not input
"0x").
<len> Read length. Range:2; unit:byte.
<data> Data read. Input format must be hex, such as 0xFFFF.

Examples

AT+CRIIC=34,f,2
+CRIIC: 0xff

OK
AT+CRIIC=34,6,2
+CRIIC: 0x140

www.simcom.com 256 / 483


A76XX Series_AT Command Manual_V1.04

OK

AT+CWIIC Write values to register of IIC device nau8810

This command is used to write values to register of IIC device nau8810.

AT+CWIIC Write values to register of IIC device nau8810


Test Command Response
AT+CWIIC=? OK
1)
Write Command
OK
AT+CWIIC=<addr>,<reg>,<d
2)
ata>,<len>
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<System Mode> System mode, values: "NO SERVICE", "GSM", "WCDMA", "LTE"
<addr> Device address. Input format must be hex, such as FF (do not input
"0x").
<reg> Register address. Input format must be hex, such as FF(do not input
"0x").
<len> Read length. Range: 2; unit: byte.
<data> Data written. Input format must be hex, such as 0xFFFF

Examples

AT+CWIIC=34,6,141,2
OK

AT+CBC Read the voltage value of the power supply

This command is used to read the voltage value of the power supply.

www.simcom.com 257 / 483


A76XX Series_AT Command Manual_V1.04

AT+CBC Read the voltage value of the power supply


Response
1)
+CBC: <vol>
Execution Command
AT+CBC
OK
2)
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<vol> The voltage value, such as 3.8.

Examples

AT+CBC
+CBC: 3.749V

OK

AT+CPMUTEMP Read the temperature of the module

This command is used to read the temperature of the module.

AT+CPMUTEMP Read the temperature of the module


Response
Execution Command +CPMUTEMP: <temp>
AT+CPMUTEMP
OK
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

www.simcom.com 258 / 483


A76XX Series_AT Command Manual_V1.04

<temp> The Temperature value, such as 29.

Examples

AT+CPMUTEMP
+CPMUTEMP: 15

OK

AT+CGDRT Set the direction of specified GPIO

This command is used to set the specified GPIO to input or output state. If setting to input state, then this
GPIO can not be set to high or low value.

AT+CGDRT Set the direction of specified GPIO


Response
Test Command +CGDRT: (list of supported <GPIO>s),(list of supported <gpio_io>s)
AT+CGDRT=?
OK
Response
1)
+CGDRT: <GPIO>,<gpio_io>
Read Command
AT+CGDRT=<GPIO>
OK
2)
ERROR
Response
Write Command 1)
AT+CGDRT=<GPIO>,<gpio_i OK
o> 2)
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<GPIO> The value is GPIO ID, different hardware versions have different
values.

www.simcom.com 259 / 483


A76XX Series_AT Command Manual_V1.04

<gpio_io> 0 in
1 out

Examples

AT+CGDRT=?
+CGDRT: (1,2,3,6,12,14,16,18,22,41,43,63,77),(0-1)

OK
AT+CGDRT=3,0
OK
AT+CGDRT=3
+CGDRT: 3,0

OK

AT+CGSETV Set the value of specified GPIO

This command is used to set the value of the specified GPIO to high or low.
The direction of specified GPIO must be set as OUT direction by using AT+CGDRT before this AT command,
otherwise an error will be returned.

AT+CGSETV Set the value of specified GPIO


Response
+CGSETV: (list of supported <GPIO>s),(list of supported
Test Command
<gpio_hl>s)
AT+CGSETV=?

OK
Response
Write Command 1)
AT+CGSETV=<GPIO>,<gpio OK
_hl> 2)
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<GPIO> The value is GPIO ID, different hardware versions have different

www.simcom.com 260 / 483


A76XX Series_AT Command Manual_V1.04

values.
<gpio_hl> 0 low
1 high

Examples

AT+CGSETV=?
+CGSETV: (1,2,3,6,12,14,16,18,22,41,43,63,77),(0-1)

OK
AT+CGSETV=6,0
OK

AT+CGGETV Get the value of specified GPIO

This command is used to get the value (high or low)of the specified GPIO.
The direction of specified GPIO must be set as IN direction by using AT+CGDRT before this AT command,
otherwise an error will be returned.

AT+CGSETV Get the value of specified GPIO


Response
Test Command +CGGETV: (list of supported <GPIO>s)
AT+CGGETV=?
OK
Response
1)
+CGGETV: <GPIO>,<gpio_hl>
Write Command
AT+CGGETV=<GPIO>
OK
2)
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<GPIO> The value is GPIO ID, different hardware versions have different
values.
<gpio_hl> 0 low
www.simcom.com 261 / 483
A76XX Series_AT Command Manual_V1.04

1 high

Examples

AT+CGGETV=?
+CGGETV: (1,2,3,6,12,14,16,18,22,41,43,63,77)

OK
AT+CGGETV=3
+CGGETV: 3,0

OK

Unsolicited Result Codes

URC Description AT Command


CMTE: <temp_level> While module’s temperature over AT+CMTE
the high threshold and below the
low threshold, the URC will occur.
This is a URC ALARM when
UNDER-VOLTAGE WARNING Current voltage is UNDER the AT+CVALARM
value which you set.
This is a URC ALARM when
OVER-VOLTAGE WARNING Current voltage is OVER the value AT+CVALARM
which you set.
This is a URC ALARM when
UNDER-VOLTAGE WARNING POWER
Current voltage is UNDER the AT+CPMVT
DOWN
value which you set.
This is a URC ALARM when
OVER-VOLTAGE WARNING POWER DOWN Current voltage is OVER the value AT+CPMVT
which you set.

Defined Values

<temp_level> -2 below -45 celsius degree.


-1 (-45,-30] celsius degree.
1 (80,85] celsius degree.
2 over 85 celsius degree.

www.simcom.com 262 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for File System


Overview of AT Commands for File System

Command Description
AT+FSCD Select directory as current directory
AT+FSMKDIR Make new directory in current directory
AT+FSRMDIR Delete directory in current directory
AT+FSLS List directories/files in current directory
AT+FSDEL Delete file in current directory
AT+FSRENAME Rename file in current directory
AT+FSATTRI Request file attributes
AT+FSMEM Check the size of available memory
AT+FSCOPY Copy an appointed file

Command Description Supported Modules


AT+FSRENAME D:/ directory file rename Only Cat1 modules
AT+FSDEL Non ASCII characters in file path Only CAT4 modules
AT+FSATTRI
AT+FSATTRI Get creating date and time message Only CAT4 modules

Detailed Description of AT Commands for File System

The file system is used to store files in a hierarchical (tree)structure, and there are some definitions and
conventions to use the AT commands.
Local storage space is mapped to "C:", "D:" for SD card. ( The A7678 does not support SD card).
NOTE: General rules for naming (both directories and files):
a) The length of actual fully qualified names of files(C:/)can not exceed 115.
b)The length of actual fully qualified names of directories and files(D:/)can not exceed 250.
c)Directory and file names can not include the following characters: \ : * ? " < [ |, ;
d)Between directory name and file/directory name, use character "/" as list separator, so it can not
appear in directory name or file name.
e) File names on “C:/” drive cannot begin with “.” .

www.simcom.com 263 / 483


A76XX Series_AT Command Manual_V1.04

If the last character of names is period "."; the flash (C:/)will auto delete this character; the SD card can
support this character, but the compatibility is not good.

AT+FSCD Select directory as current directory

This command is used to select a directory. The Module supports absolute path and relative path.

AT+FSCD Select directory as current directory


Test Command Response
AT+FSCD=? OK
Response
Read Command +FSCD: <curr_path>
AT+FSCD?
OK
Response
1)If set current directory successfully:
+FSCD: <curr_path>
Write Command
AT+FSCD=<path>
OK
2)If set current directory failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<path> Directory for selection.


<curr_path> Current directory.

Examples

AT+FSCD=C:
+FSCD: C:/

OK
AT+FSCD=C:/
+FSCD: C:/

OK
AT+FSCD?

www.simcom.com 264 / 483


A76XX Series_AT Command Manual_V1.04

+FSCD: C:/

OK
AT+FSCD=D:
+FSCD: D:/

OK

NOTE

If <path> is ".", it will go back to previous level of directory.

AT+FSMKDIR Make new directory in current directory

This command is used to create a new directory in current directory. Support "D:".

AT+FSMKDIR Make new directory in current directory


Test Command Response
AT+FSMKDIR=? OK
Response
1)If successfully:
Write Command
OK
AT+FSMKDIR=<dir>
2)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<dir> Directory name which does not already exist in current directory.

Examples

AT+FSMKDIR=SIMTech
OK
AT+FSCD?

www.simcom.com 265 / 483


A76XX Series_AT Command Manual_V1.04

+FSCD: D:/

OK
AT+FSLS
+FSLS: SUBDIRECTORIES:
SIMTech

OK

NOTE

Only support "D:".

AT+FSRMDIR Delete directory in current directory

This command is used to delete existing directory in current directory. Support "D:".

AT+FSRMDIR Delete directory in current directory


Test Command Response
AT+FSRMDIR=? OK
Response
1)If successfully:
Write Command
OK
AT+FSRMDIR=<dir>
2)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<dir> The directory name which already exists in current directory.

Examples

AT+FSRMDIR=SIMTech
OK

www.simcom.com 266 / 483


A76XX Series_AT Command Manual_V1.04

AT+FSCD?
+FSCD: D:/

OK
AT+FSLS
+FSLS: SUBDIRECTORIES:

OK

NOTE

Only support "D:".

AT+FSLS List directories/files in current directory

This command is used to list informations of directories and/or files in current directory. Support "C:", "D:".

AT+FSLS List directories/files in current directory


Response
Test Command +FSLS: (list of supported <type>s)
AT+FSLS=?
OK
Response
Read Command +FSLS: SUBDIRECTORIES:<dir_num>,FILES:<file_num>
AT+FSLS?
OK
Response
[+FSLS: SUBDIRECTORIES:
<list of subdirectories>]
Write Command
AT+FSLS=<type> [+FSLS: FILES:
<list of files>]

OK
Execution Command Response
AT+FSLS [+FSLS: SUBDIRECTORIES:
<list of subdirectories>]

[+FSLS: FILES:
<list of files>]

www.simcom.com 267 / 483


A76XX Series_AT Command Manual_V1.04

OK
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<dir_num> Integer type, the number of subdirectories in current directory.


<file_num> Integer type, the number of files in current directory.
<type> 0 list both subdirectories and files
1 list subdirectories only
2 list files only

Examples

AT+FSLS?
+FSLS: SUBDIRECTORIES:2,FILES:2

OK
AT+FSLS
+FSLS: SUBDIRECTORIES:
FirstDir
SecondDir

+FSLS: FILES:
image_0.jpg
image_1.jpg

OK
AT+FSLS=2
+FSLS: FILES:
image_0.jpg
image_1.jpg

OK

AT+FSDEL Delete file in current directory

This command is used to delete a file in current directory. Before do that, it needs to use AT+FSCD select
www.simcom.com 268 / 483
A76XX Series_AT Command Manual_V1.04

the father directory as current directory. Support "C:", "D:".

AT+FSDEL Delete file in current directory


Test Command Response
AT+FSDEL=? OK
Response
1)If successfully:
Write Command
OK
AT+FSDEL=<filename>
2)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<filename> String with or without double quotes, file name which is relative and
already existing.

Examples

AT+FSDEL=image_0.jpg
OK

NOTE

If <filename> is *.*, it means delete all files in current directory.

AT+FSRENAME Rename file in current directory

This command is used to rename a file in current directory. Support "C:", "D:".

AT+FSRENAME Rename file in current directory


Test Command Response
AT+FSRENAME=? OK
Write Command Response
AT+FSRENAME=<old_name 1)If successfully:

www.simcom.com 269 / 483


A76XX Series_AT Command Manual_V1.04

>,<new_name> OK
2)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<old_name> String with or without double quotes, file name which is existed in
current directory.
<new_name> New name of specified file, string with or without double quotes.

Examples

AT+FSRENAME=image_0.jpg,image_1.jpg
OK

AT+FSATTRI Request file attributes

This command is used to request the attributes of file which exists in current directory. Support "C:", "D:".

AT+FSATTRI Request file attributes


Test Command Response
AT+FSATTRI=? OK
Response
1)If successfully:
+FSATTRI: <file_size>
Write Command
AT+FSATTRI=<filename>
OK
2)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

www.simcom.com 270 / 483


A76XX Series_AT Command Manual_V1.04

String with or without double quotes, file name which is in current


<filename>
directory.
<file_size> The size of specified file, and the unit is in Byte.

Examples

AT+FSATTRI=image_0.jpg
+FSATTRI: 8604

OK

AT+FSMEM Check the size of available memory

This command is used to check the size of available memory. The response will list total size and used size
of local storage space if present and mounted. Support "C:", "D:".

AT+FSMEM Check the size of available memory


Test Command Response:
AT+FSMEM=? OK
Response:
1)If successfully, currently C:/:
+FSMEM: C:(<total>,<used>)

OK
Execution Command
2)If successfully, currently D:/:
AT+FSMEM
+FSMEM: D:(<total>,<used>)

OK
3)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<total> The total size of local storage space.


<used> The used size of local storage space.

www.simcom.com 271 / 483


A76XX Series_AT Command Manual_V1.04

Examples

AT+FSMEM
+FSMEM: C:(11348480, 2201600)

OK

NOTE

The unit of storage space size is in Byte.

AT+FSCOPY Copy an appointed file

This command is used to copy an appointed file on C:/ to an appointed directory on C:/, the new file name
should give in parameter. Support "C:", "D:".

AT+FSCOPY Copy an appointed file


Test Command Response
AT+FSCOPY=? OK
Response
1)If successfully, synchronous mode:
+FSCOPY: <percent>
[+FSCOPY: <percent>]

OK
2)If successfully, asynchronous mode:
OK

Write Command +FSCOPY: <percent>


AT+FSCOPY=<file1>,<file2>[
,<sync_mode>] [+FSCOPY: <percent>]

+FSCOPY: END
3)If any error:
SD CARD NOT PLUGGED IN
FILE IS EXISTING
FILE NOT EXISTING
DIRECTORY IS EXISTED
DIRECTORY NOT EXISTED
INVALID PATH NAME

www.simcom.com 272 / 483


A76XX Series_AT Command Manual_V1.04

INVALID FILE NAME


SD CARD HAVE NO ENOUGH MEMORY
EFS HAVE NO ENOUGH MEMORY
FILE CREATE ERROR
READ FILE ERROR
WRITE FILE ERROR
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<file1> The sources file name or the whole path name with sources file name.
<file2> The destination file name or the whole path name with destination file
name.
<percent> The percent of copy done. The range is 0.0 to 100.0
<sync_mode> The execution mode of the command:
0 synchronous mode
1 asynchronous mode

Examples

AT+FSCOPY=C:/TESTFILE,COPYFILE //Copy file TESTFILE on C:/ to C:/COPYFILE


+FSCOPY: 0.0

+FSCOPY: 9.7

+FSCOPY: 19.4

+FSCOPY: 100.0

OK

NOTE

The <file1> and <file2> should give the whole path and name, if only given file name, it will refer to
current path (AT+FSCD)and check the file’s validity.
If <file2> is a whole path and name, make sure the directory exists, make sure that the file name does
not exist or the file name is not the same name as the sub folder name, otherwise return error.

www.simcom.com 273 / 483


A76XX Series_AT Command Manual_V1.04

<percent> report refer to the copy file size. The big file maybe report many times, and little file report
less.
If <sync_mode> is 1, the command will return OK immediately, and report final result with +FSCOPY:
END.

www.simcom.com 274 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for File Transmission


Overview of AT Commands for File Transmission

Command Description
AT+CFTRANRX Transfer a file to EFS
AT+CFTRANTX Transfer a file from EFS to host
AT+CFTRXBUF Sets the size of the buffer to transfer files to EFS

Command Description Supported Project


AT+CFTRXBUF A7600C1-XXXX
A7678

Detailed Description of AT Commands for File Transmission

AT+CFTRANRX Transfer a file to EFS

This command is used to transfer a file to EFS.Support "C:", "D:".

AT+CFTRANRX Transfer a file to EFS


Response
Test Command +CFTRANRX: [{non-ascii}]"FILEPATH"
AT+CFTRANRX=?
OK
Response
1)If successfully:
>
Write Command
OK
AT+CFTRANRX=<filepath>,<l
2)If failed:
en>
>
ERROR
3)If failed:

www.simcom.com 275 / 483


A76XX Series_AT Command Manual_V1.04

ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<filepath> The path of the file on EFS


<len> The length of the file data to send.
Because of the system resources, The length could not set too large. If
use the UART to send data, it may can set to 3Mb. If use USB to send
data, it may just can set to 200Kb. If limit the send speed, it can set
larger. The actual size could not ensure. Usually it is safer to set a
smaller size.

Examples

AT+CFTRANRX="c:/t1.txt",10
>
OK
AT+CFTRANRX="d:/MyDir/t1.txt",10
>
OK

NOTE

1.The <filepath> must be a full path with the directory path, make sure that the file name does not exist
under the path.
2.If sending file fails, increase the delay time between each 256 byte reach to 50ms, and then try to
send file again.
3. Only Cat4 modules support Non-ASCII characters in file path.

AT+CFTRANTX Transfer a file from EFS to host

This command is used to transfer a file from EFS to host.

AT+CFTRANTX Transfer a file from EFS to host

www.simcom.com 276 / 483


A76XX Series_AT Command Manual_V1.04

Response
Test Command +CFTRANTX: [{non-ascii}]"FILEPATH"
AT+CFTRANTX=?
OK
Response
1)If successfully:
[+CFTRANTX: DATA,<len>

Write Command
+CFTRANTX: DATA,<len>]
AT+CFTRANTX=<filepath>[,<
+CFTRANTX: 0
location>][,<size>]

OK
2)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<filepath> The path of the file on EFS


<len> The length of the following file data to output.
<location> The beginning of the file data to output.
<size> The length of the file data to output.

Examples

AT+CFTRANTX="c:/t1.txt"
+CFTRANTX: DATA, 11
Testcontent
+CFTRANTX: 0

OK
AT+CFTRANTX="d:/MyDir/t1.txt"
+CFTRANTX: DATA, 11
Testcontent
+CFTRANTX: 0

OK
AT+CFTRANTX="d:/MyDir/t1.txt",1,4
+CFTRANTX: DATA, 4
estc

www.simcom.com 277 / 483


A76XX Series_AT Command Manual_V1.04

+CFTRANTX: 0

OK

NOTE

The <filepath> must be a full path with the directory path.


If not set the size, it means range from location to the end of the file.
If the (size + location)lager than the file size, it means range from location to the end of the file.

AT+CFTRXBUF Sets the size of the buffer to transfer files to EFS

This command is used to set the size of the buffer to transfer files to EFS.Support “C:”, “D:”.

AT+CFTRANRX Transfer a file to EFS


Response
Test Command +CFTRXBUF: (list of supported <buffsize_level>s)
AT+CFTRXBUF=?
OK
Response
Read Command +CFTRXBUF: <buffsize_level>
AT+CFTRXBUF?
OK
Response
Write Command a)If successfully:
AT+CFTRXBUF=<buffsize_le OK
vel> c)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<buffsize_level> The size of the buffer to transfer files to EFS.


0 -- 20Kb(20,480 bytes)
1 -- 40Kb(40,960 bytes)

www.simcom.com 278 / 483


A76XX Series_AT Command Manual_V1.04

Examples

AT+CFTRXBUF=0
OK
AT+CFTRXBUF?
+CFTRXBUF: 0

OK

NOTE

The default buffer size is 20KB, which is sufficient for basic file transfer requirements.When transferring
large files fails, if you are unwilling to extend the delay time in order to ensure the transfer speed, you
can increase the buffer size to 40KB, but this may affect multiple application scenarios.

www.simcom.com 279 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for Internet Service


Overview of AT Commands for Internet Service

Command Description
AT+CHTPSERV Set HTP server information
AT+CHTPUPDATE Updating date time using HTP protocol
AT+CNTP Update system time

Detailed Description of AT Commands for Internet Service

AT+CHTPSERV Set HTP server information

This command is used to add or delete HTP server information. There are maximum 16 HTP servers.

AT+CHTPSERV Set HTP server information


Response
+CHTPSERV: "ADD","HOST",(1-65535),(0-1)[,"PROXY",(1-65535)]
Test Command
+CHTPSERV: "DEL",(0-15)
AT+CHTPSERV=?

OK
Response
1)
OK
2)
Read Command +CHTPSERV:
AT+CHTPSERV? <index><host>,<port>,<http_version>[,<proxy>,<proxy_port>]

+CHTPSERV: <index><host>,<port>[,<proxy>,<proxy_port>]

OK
Write Command Response
AT+CHTPSERV=<cmd>,<ho 1)If successfully:
www.simcom.com 280 / 483
A76XX Series_AT Command Manual_V1.04

st_or_idx>[,<port>,<http_ver OK
sion>[,<proxy>,<proxy_port 2)If failed:
>]] ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<cmd> This command to operate the HTP server list.


"ADD" add a HTP server item to the list
"DEL" delete a HTP server item from the list
<host_or_idx> If the <cmd> is “ADD”, this field is the same as <host>, length is 1-255;
If the <cmd> is “DEL”, this field is the index of the HTP server item to
be deleted from the list.
<host> The HTP server address, length is 1-255.
<port> The HTP server port, the range is (1-65535).
<http_version> The HTTP version of the HTP server:
0 HTTP 1.0
1 HTTP 1.1
<proxy> The proxy address, length is 1-255.
<proxy_port> The port of the proxy, the range is (1-65535).
<index> The HTP server index.

Examples

AT+CHTPSERV="ADD","www.google.com",80,1
OK

AT+CHTPUPDATE Updating date time using HTP protocol

This command is used to updating date time using HTP protocol.

AT+CHTPUPDATE Updating date time using HTP protocol


Test Command Response
AT+CHTPUPDATE=? OK
Read Command Response
AT+CHTPUPDATE? +CHTPUPDATE: <status>

www.simcom.com 281 / 483


A76XX Series_AT Command Manual_V1.04

OK
Execute Command Response
AT+CHTPUPDATE 1)If successfully:
OK

+CHTPUPDATE: <err>
2)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<status> The status of HTP module:


Updating HTP module is synchronizing date time
NULL HTP module is idle now
<err> The result of the HTP updating

Examples

AT+CHTPUPDATE
OK

+CHTPUPDATE: 0

AT+CNTP Update system time

This command is used to update system time with NTP server.

AT+CNTP Update system time


Test Command Response
AT+CNTP=? +CNTP: "HOST",(-96~96)

OK
Read Command Response
AT+CNTP? +CNTP: <host>,<timezone>

OK

www.simcom.com 282 / 483


A76XX Series_AT Command Manual_V1.04

Write Command Response


AT+CNTP=<host>[,<timezon 1)If successfully:
e>] OK
2)If failed:
ERROR
Execute Command Response
AT+CNTP 1)If successfully:
OK

+CNTP: <err_code>
2)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<host> NTP server address, length is 0-255.


<timezone> Local time zone,the range is (-96 to 96), default value is 32.

Examples

AT+CNTP="202.120.2.101",32
OK
AT+CNTP
OK

+CNTP: 0

Command Result Codes

Description of <err> of HTP

<err> Description
0 Operation succeeded

www.simcom.com 283 / 483


A76XX Series_AT Command Manual_V1.04

1 Unknown error
2 Wrong parameter
3 Wrong date and time calculated
4 Network error

Description of <err> of NTP

<err> Description
0 Operation succeeded
1 Unknown error
2 Wrong parameter
3 Wrong date and time calculated
4 Network error
5 Time zone error
6 Time out error

www.simcom.com 284 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for TCP/IP


Overview of AT Commands for TCP/IP

Command Description
AT+NETOPEN Start Socket Service
AT+NETCLOSE Stop Socket Service
AT+CIPOPEN Establish Connection in Multi-Socket Mode
AT+CIPSEND Send data through TCP or UDP Connection
AT+CIPRXGET Set the Mode to Retrieve Data
AT+CIPCLOSE Close TCP or UDP Socket
AT+IPADDR Inquire Socket PDP address
AT+CIPHEAD Add an IP Header When Receiving Data
AT+CIPSRIP Show Remote IP Address and Port
AT+CIPMODE Set TCP/IP Application Mode
AT+CIPSENDMODE Set Sending Mode
AT+CIPTIMEOUT Set TCP/IP Timeout Value
AT+CIPCCFG Configure Parameters of Socket
AT+SERVERSTART Startup TCP Sever
AT+SERVERSTOP Stop TCP Sever
AT+CIPACK Query TCP Connection Data Transmitting Status
AT+CDNSGIP Query the IP Address of Given Domain Name
AT+CSOCKSETPN Set acitve PDP context's profile

Detailed Description of AT Commands for TCP/IP

AT+NETOPEN Start Socket Service

AT+NETOPEN is used to start service by activating PDP context. You must execute AT+NETOPEN before
any other TCP/UDP related operations.

www.simcom.com 285 / 483


A76XX Series_AT Command Manual_V1.04

AT+NETOPEN Start Socket Service


Response
Read Command +NETOPEN: <net_state>
AT+NETOPEN?
OK
Response
1)If the PDP context has not been activated or the network closed
abnormally, response:
OK

+NETOPEN: <err>
Execute Command
2)When the PDP context has been activated successfully, if you
AT+NETOPEN
execute AT+NETOPEN again, response:
+IP ERROR: Network is already opened

ERROR
3)other:
ERROR
Parameter Saving Mode NO_SAVE
Range: 3000ms-120000ms
Max Response Time default: 120000ms
(it can be set by AT+CIPTIMEOUT)
Reference 3GPP TS 27.005

Defined Values

<net_state> Integer type, indicates the state of PDP context activation.


0 network close (deactivated)
1 network open(activated)
<err> Integer type, the result of operation.
0 is success, other value is failure, please refer to Chapter 15.3.2 for
details

Examples

AT+NETOPEN?
+NETOPEN: 1

OK
AT+NETOPEN
OK

+NETOPEN: 0
www.simcom.com 286 / 483
A76XX Series_AT Command Manual_V1.04

AT+NETCLOSE Stop Socket Service

AT+NETCLOSE is used to stop service by deactivating PDP context. It can also close all the opened socket
connections when you didn’t close these connections by AT+CIPCLOSE.

AT+NETCLOSE Stop Socket Service


Response
1)If the PDP context has been activated, response:
OK

+NETCLOSE: <err>
2)If the PDP context has been activated and one connection is in
non-transparent mode and transparent mode, response:

OK

Execute Command
CLOSED
AT+NETCLOSE

+CIPCLOSE: <link_num>,<err>

+NETCLOSE: <err>
3)If the PDP context has not been activated, response:
+NETCLOSE: <err>

ERROR
4)Others:
ERROR
Parameter Saving Mode NO_SAVE
Range: 3000ms-120000ms
Max Response Time default: 120000ms
(it can be set by AT+CIPTIMEOUT)
Reference

Defined Values

<err> Integer type, the result of operation.


0 is success, other value is failure, please refer to Chapter 15.3.2 for
details

www.simcom.com 287 / 483


A76XX Series_AT Command Manual_V1.04

Examples

AT+NETCLOSE
OK

+NETCLOSE: 0

AT+CIPOPEN Establish Connection in Multi-Socket Mode

You can use AT+CIPOPEN to establish a connection with TCP server and UDP server, the maximum of the
connections is 10.

AT+CIPOPEN Establish Connection in Multi-Socket Mode


Response
Test Command +CIPOPEN: (0-9),("TCP","UDP")
AT+CIPOPEN=?
OK
Response
+CIPOPEN:
<link_num>[,<type>,<serverIP>,<serverPort>,<index>]
+CIPOPEN:
Read Command <link_num>[,<type>,<serverIP>,<serverPort>,<index>]
AT+CIPOPEN? […]

OK
If a connection identified by <link_num>has not been established
successfully, only +CIPOPEN: <link_num> will be returned.
Response
1)if PDP context has been activated successfully, response:
OK

+CIPOPEN: <link_num>,<err>
Write Command 2)when the <link_num> is greater than 10, or when
TCP connection AT+CIPMODE=1 is set, the <link_num> is greater than
AT+CIPOPEN=<link_num>,"TC 0,response:
P",<serverIP>,<serverPort>[,<lo +IP ERROR: Invalid parameter
calPort>]
ERROR
3)If PDP context has not been activated, or the connection has
been established, or parameter is incorrect, or other errors,
response:
+CIPOPEN: <link_num>,<err>

www.simcom.com 288 / 483


A76XX Series_AT Command Manual_V1.04

ERROR
4)Transparent mode for TCP connection:
When you want to use transparent mode to transmit data, you
should set AT+CIPMODE=1 before AT+NETOPEN. And if
AT+CIPMODE=1 is set, the <link_num> is restricted to be only 0.
if success
CONNECT [<text>]
if failure
CONNECT FAIL
5)Others:
ERROR
1)If PDP context has been activated successfully, response:
+CIPOPEN: <link_num>,0

OK
2)When the <link_num> is greater than 10, response:
+IP ERROR: Invalid parameter
Write Command
UDP Connection
ERROR
AT+CIPOPEN=<link_num>,"UD
If PDP context has not been activated, or the connection has been
P",,,<localPort>
established, or parameter is incorrect, or other errors, response:
+CIPOPEN: <link_num>,<err>

ERROR
3)Others:
ERROR
Parameter Saving Mode NO_SAVE
Range: 3000ms-120000ms
Max Response Time default: 120000ms
(it can be set by AT+CIPTIMEOUT)
Reference

Defined Values

<link_num> Integer type, identifies a connection. Range is 0-9.


If AT+CIPMODE=1 is set, the <link_num> is restricted to be only 0.0 is
success, other value is failure, please refer to Chapter 4 for details
<type> String type, identifies the type of transmission protocol.
TCP Transmission Control Protocol
UDP User Datagram Protocol
<serverIP> String type, identifies the IP address of server. The IP address format
consists of 4 octets, separated by decimal point, like
"AAA.BBB.CCC.DDD". Also the domain name is supported here.

www.simcom.com 289 / 483


A76XX Series_AT Command Manual_V1.04

<serverPort> Integer type, identifies the port of TCP server, range is 0-65535.
NOTE:
When open port as TCP, the port must be the opened TCP port;
When open port as UDP, the port may be any port.
<localPort> Integer type, identifies the port of local socket, range is 0-65535.
<index> Integer type, indicates whether the module is used as a client or
server. When used as server, the range is 0-3,<index> is the server
index to which the client is linked.
-1 TCP client
0-3 TCP server index
<text> String type, indicates CONNECT result code.
<err> Integer type, the result of operation.
0 is success, other value is failure, please refer to Chapter 15.3.2 for
details

Examples

AT+CIPOPEN=?
+CIPOPEN: (0-9),("TCP","UDP")

OK
AT+CIPOPEN?
+CIPOPEN: 0
+CIPOPEN: 1,"TCP","183.230.174.137",6031,-1
+CIPOPEN: 2
+CIPOPEN: 3
+CIPOPEN: 4
+CIPOPEN: 5,"UDP","183.230.174.137",6031,-1
+CIPOPEN: 6
+CIPOPEN: 7
+CIPOPEN: 8
+CIPOPEN: 9

OK
AT+CIPOPEN=0,"TCP","183.230.174.137",6031
OK //TCP connection

+CIPOPEN: 0,0
AT+CIPOPEN=5,"UDP",,,6031
+CIPOPEN: 5,0 // UDP Connection

OK

www.simcom.com 290 / 483


A76XX Series_AT Command Manual_V1.04

AT+CIPSEND Send data through TCP or UDP Connection

AT+CIPSEND is used to send data to remote side. If service type is TCP, the data is firstly sent to the
module’s internal TCP/IP stack, and then sent to server by protocol stack. The <length> field may be empty.
While it is empty, each <Ctrl+Z> character present in the data should be coded as <ETX><Ctrl+Z>. Each
<ESC> character present in the data should be coded as <ETX><ESC>. Each <ETX> character will be
coded as <ETX><ETX>. Single <Ctrl+Z> means end of the input data. Single <ESC> is used to cancel the
sending.
<ETX> is 0x03, and <Ctrl+Z> is 0x1A,<ESC> is 0x1B.

AT+CIPSEND Send data through TCP or UDP Connection


Response
Test Command AT+CIPSEND: (0-9),(1-1500)
AT+CIPSEND=?
OK
Response
1)If the connection identified by <link_num> has been established
successfully, response:
>
<input data>
Write Command CTRL+Z
If service type is "TCP", send data OK
with changeable length
AT+CIPSEND=<link_num> +CIPSEND: <link_num>,<reqSendLength>,<cnfSendLength>
2)If <reqSendLength> is equal <cnfSendLength>, it means that
Response ">", then type data to the data has been sent to TCP/IP protocol stack successfully.
send, tap CTRL+Z to send data, 3)If the connection has not been established, abnormally closed,
tap ESC to cancel the operation or parameter is incorrect, response:
+CIPERROR: <err>

ERROR
4)Others:
ERROR
Response
1)If the connection identified by <link_num> has been established
successfully, response:
Write Command
>
If service type is "TCP", send data
<input data with specified length>
with fixed length
OK
AT+CIPSEND=<link_num>,<len
gth>
+CIPSEND: <link_num>,<reqSendLength>,<cnfSendLength>
2)If <reqSendLength> is equal <cnfSendLength>, it means that
the data has been sent to TCP/IP protocol stack successfully.
3)If the connection has not been established, abnormally closed,

www.simcom.com 291 / 483


A76XX Series_AT Command Manual_V1.04

or parameter is incorrect, response:


+CIPERROR: <err>

ERROR

4)Others:
ERROR
Response
1)If the connection identified by <link_num> has been established
successfully, response:
>
Write Command <input data>
If service type is "UDP", send data CTRL+Z
with changeable length OK

AT+CIPSEND=<link_num>,,<ser +CIPSEND: <link_num>,<reqSendLength>,<cnfSendLength>


verIP>,<serverPort>
Response ">", then type data to 2)If the connection has not been established, abnormally closed,
send, tap CTRL+Z to send data, or parameter is incorrect, response:
tap ESC to cancel the operation +CIPERROR: <err>

ERROR
3)Others:
ERROR
Response
1)If the connection identified by <link_num> has been established
successfully, response:
>
Write Command <input data with specified length>
If service type is "UDP", send data OK
with fixed length
AT+CIPSEND=<link_num>,<len +CIPSEND: <link_num>,<reqSendLength>,<cnfSendLength>
gth>,<serverIP>,<serverPort> 2)If the connection has not been established, abnormally closed,
Response ">", type data until the or parameter is incorrect, response:
data length is equal to <length> +CIPERROR: <err>

ERROR
3)Others:
ERROR
Parameter Saving Mode NO_SAVE
Range: 3000ms-120000ms
Max Response Time default: 120000ms
(it can be set by AT+CIPTIMEOUT)
Reference

www.simcom.com 292 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<link_num> Integer type, identifies a connection. Range is 0-9.


<length> Integer type, indicates the length of sending data, range is 1-1500.
<serverIP> String type, identifies the IP address of server. The IP address format
consists of 4 octets, separated by decimal point, like
"AAA.BBB.CCC.DDD". Also the domain name is supported here.
<serverPort> Integer type, identifies the port of TCP server, range is 0-65535.
NOTE:
When open port as TCP, the port must be the opened TCP port;
When open port as UDP, the port may be any port.
But, for Qualcomm, connecting the port 0 is regarded as an invalid
operation.
<reqSendLength> Integer type, the length of the data requested to be sent
<cnfSendLength> Integer type, the length of the data confirmed to have been sent
-1 the connection is disconnected.
0 own send buffer or other side’s congestion window are full.
Note: If the <cnfSendLength> is not equal to the <reqSendLength>,
the socket then cannot be used further.
<err> Integer type, the result of operation.
0 is success, other value is failure, please refer to Chapter 15.3.2 for
details

Examples

AT+CIPSEND=?
+CIPSEND: (0-9),(1-1500)

OK
AT+CIPSEND=1,5
>12345 // If service type is "TCP", send data with
OK fixed length

+CIPSEND: 1,5,5
AT+CIPSEND=8,5,"183.230.174.137",6031
>12345 // If service type is "UDP", send data with
OK fixed length

+CIPSEND: 8,1,1

NOTE

www.simcom.com 293 / 483


A76XX Series_AT Command Manual_V1.04

If you use UDP to send more than 1400 bytes of data when the server does not receive data, this may
be the reason for the carrier, in this case please send no more than 1400 bytes of data.

If you use TCP to send data, the instruction can be followed by a comma just like "AT+CIPSEND=0," or
"AT+CIPSEND=0,10," without an error, but it doesn't make any sense

AT+CIPRXGET Set the Mode to Retrieve Data

If set <mode> to 1, after receiving data, the module will buffer it and report a URC as "+CIPRXGET:
1,<link_num>" to notify the host. Then host can retrieve data by AT+CIPRXGET.
If set <mode> to 0, the received data will be outputted to COM port directly by URC as "RECV FROM:<IP
ADDRESS>:<PORT><CR><LF>+IPD(data length)<CR><LF><data>".
The default value of <mode> is 0.

AT+CIPRXGET Set the Mode to Retrieve Data


Response
Test Command +CIPRXGET: (0-4),(0-9),(1-1500)
AT+CIPRXGET=?
OK
Response
Read Command +CIPRXGET: <mode>
AT+CIPRXGET?
OK
Response
Write Command
1)If the parameter is correct, response:
AT+CIPRXGET=<mode>
OK
In this case,<mode> can only be 0
2)Others:
or 1
ERROR
1)If <len> field is empty, the default value to read is 1500.
If the buffer is not empty, response:
+CIPRXGET: <mode>,<link_num>,<read_len>,<rest_len>
<data>ACSII form

Write Command
OK
AT+CIPRXGET=2,<link_num>[,<
2)If the buffer is empty, response:
len>]
+IP ERROR: No data
Retrieve data in ACSII form

ERROR
3)If the parameter is incorrect or other error, response:
+IP ERROR: <err_info>

www.simcom.com 294 / 483


A76XX Series_AT Command Manual_V1.04

ERROR
4)Others:
ERROR
Response
1)If <length> field is empty, the default value to read is 750.
If the buffer is not empty, response:
+CIPRXGET: <mode>,<link_num>,<read_len>,<rest_len>
<data>
hex form

Write Command OK
AT+CIPRXGET=3,<link_num>[,< 2)If the buffer is empty, response:
len>] +IP ERROR: No data
Retrieve data in hex form
ERROR
3)If the parameter is incorrect or other error, response:
+IP ERROR: <err_info>

ERROR
4)Others:
ERROR
Response
1)If the parameter is correct, response:
+CIPRXGET: 4,<link_num>,<rest_len>

OK
Write Command
AT+CIPRXGET=4,<link_num> 2)If the parameter is incorrect or other error, response:
+IP ERROR: <err_info>

ERROR
3)Others
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 8s
Reference

Defined Values

<mode> Integer type, sets the mode to retrieve data


0 set the way to get the network data automatically
1 set the way to get the network data manually
2 read data, the max read length is 1500

www.simcom.com 295 / 483


A76XX Series_AT Command Manual_V1.04

3 read data in HEX form, the max read length is 750


4 get the rest data length
<link_num> Integer type, identifies a connection. Range is 0-9.
<len> Integer type, the data length to be read.
Not required, the default value is 1500 when <mode>=2, and 750
when <mode>=3.
<read_len> Integer type, the length of data that has been read.
<rest_len> Integer type, the length of data which has not been read in the buffer.
<err_info> String type, displays the cause of occurring error, please refer to
Chapter 15.3.1 for more details.

Examples

AT+CIPRXGET=?
+CIPRXGET: (0-4),(0-9),(1-1500)

OK
AT+CIPRXGET?
+CIPRXGET: 1

OK
AT+CIPRXGET=1
OK
AT+CIPRXGET=2,0
+CIPRXGET: 2,0,6,0
123456

OK
AT+CIPRXGET=3,0
+CIPRXGET: 3,0,6,0
313233343536

OK
AT+CIPRXGET=4,0
+CIPRXGET: 4,0,18

OK

AT+CIPCLOSE Close TCP or UDP Socket

AT+CIPCLOSE is used to close a TCP or UDP Socket

www.simcom.com 296 / 483


A76XX Series_AT Command Manual_V1.04

AT+CIPCLOSE Close TCP or UDP Socket


Response
Test Command +CIPCLOSE: (0-9)
AT+CIPCLOSE=?
OK
Response
+CIPCLOSE:
<link0_state>,<link1_state>,<link2_state>,<link3_state>,<link
Read Command
4_state>,<link5_state>,<link6_state>,<link7_state>,<link8_sta
AT+CIPCLOSE?
te>,<link9_state>

OK
Response
1)If service type is TCP and the connection identified by
<link_num> has been established, response
OK

+CIPCLOSE: <link_num>,<err>
2)If service type is TCP and the access mode is transparent mode,
response:
OK

CLOSED

+CIPCLOSE: <link_num>,<err>
3)If service type is UDP and the connection identified by
<link_num> has been established and closed successfully,
Write Command response:
AT+CIPCLOSE=<link_num> +CIPCLOSE: <link_num>,0

OK
4)If service type is UDP and access mode is transparent mode,
response:
CLOSED

+CIPCLOSE: <link_num>,<err>

OK
5)If the connection has not been established, abnormally closed,
or parameter is incorrect, response:
+CIPCLOSE: <link_num>,<err>

ERROR
6)Others:

www.simcom.com 297 / 483


A76XX Series_AT Command Manual_V1.04

ERROR
Parameter Saving Mode NO_SAVE
Range: 3000ms-120000ms
Max Response Time default: 120000ms
(it can be set by AT+CIPTIMEOUT)
Reference

Defined Values

<link_num> Integer type, identifies a connection. Range is 0-9.


<linkX_state> Integer type, indicates state of connection identified by <link_num>.
Range is 0-1.
0 disconnected
1 connected
<err> Integer type, the result of operation.
0 is success, other value is failure, please refer to Chapter 15.3.2 for
details

Examples

AT+CIPCLOSE=?
+CIPCLOSE: (0-9)

OK
AT+CIPCLOSE?
+CIPCLOSE: 0,0,0,0,0,1,0,0,1,0

OK
AT+CIPCLOSE=0
OK

+CIPCLOSE: 0,0

AT+IPADDR Inquire Socket PDP address

AT+IPADDR is used to get active PDP address.

AT+IPADDR Inquire Socket PDP Address


Execute Command Response
AT+IPADDR 1)If PDP context has been activated successfully, response
www.simcom.com 298 / 483
A76XX Series_AT Command Manual_V1.04

+IPADDR: <ip_address>

OK
2)
+IP ERROR: Network not opened

ERROR
Parameter Saving Mode NO_SAVE
Max Response Time default: 9000ms
Reference -

Defined Values

<ip_address> String type, identifies the IP address of current active socket PDP.

Examples

AT+IPADDR
+IPADDR: 10.84.17.161

OK

AT+CIPHEAD Add an IP Header When Receiving Data

AT+CIPHEAD is used to add an IP header when receiving data.

AT+CIPHEAD Add an IP Header When Receiving Data


Response
Test Command +CIPHEAD: (0-1)
AT+CIPHEAD=?
OK
Response
Read Command +CIPHEAD: <mode>
AT+CIPHEAD?
OK
Response
1)If the parameter is correct, response:
Write Command
OK
AT+CIPHEAD=<mode>
2)
ERROR
www.simcom.com 299 / 483
A76XX Series_AT Command Manual_V1.04

Response
Execute Command
Set default value:(<mode>=1)
AT+CIPHEAD
OK
Parameter Saving Mode NO_SAVE
Max Response Time default: 9000ms

Reference -

Defined Values

<mode> Integer type, indicates whether adding an IP header or not when


receiving data
0 not add IP header
1 add IP header, the format is "+IPD(data length)"

Examples

AT+CIPHEAD=?
+CIPHEAD: (0-1)

OK
AT+CIPHEAD?
+CIPHEAD: 1

OK
AT+CIPHEAD=1
OK
AT+CIPHEAD
OK

AT+CIPSRIP Show Remote IP Address and Port

AT+CIPSRIP is used to set whether to display IP address and port of server when receiving data.

AT+CIPSRIP Show Remote IP Address and Port


Response
Test Command +CIPSRIP: (0-1)
AT+CIPSRIP=?
OK
Read Command Response

www.simcom.com 300 / 483


A76XX Series_AT Command Manual_V1.04

AT+CIPSRIP? +CIPSRIP: <mode>

OK
Response
1)If the parameter is correct, response:
Write Command
OK
AT+CIPSRIP=<mode>
2)
ERROR
Response
Execute Command
Set default value:(<mode>=1)
AT+CIPSRIP
OK
Parameter Saving Mode NO_SAVE
Max Response Time default: 9000ms

Reference -

Defined Values

<mode> Integer type, indicates whether to show IP address and port of server
or not when receiving data.
0 not show
1 show, the format is as follows:
"RECV FROM:<IP ADDRESS>:<PORT>"

Examples

AT+CIPSRIP=?
+CIPSRIP: (0-1)

OK
AT+CIPSRIP?
+CIPSRIP: 1

OK
AT+CIPSRIP=0
OK
AT+CIPSRIP
OK

www.simcom.com 301 / 483


A76XX Series_AT Command Manual_V1.04

AT+CIPMODE Set TCP/IP Application Mode

AT+CIPMODE is used to select transparent mode(data mode) or non-transparent mode(command


mode).The default mode is non-transparent mode.

AT+CIPMODE Set TCP/IP Application Mode


Response
Test Command +CIPMODE: (0-1)
AT+CIPMODE=?
OK
Response
Read Command +CIPMODE: <mode>
AT+CIPMODE?
OK
Response
1)If the parameter is correct, response:
Write Command
OK
AT+CIPMODE=<mode>
2)
ERROR
Response
Execute Command
Set default value:(<mode>=0)
AT+CIPMODE
OK
Parameter Saving Mode NO_SAVE
Max Response Time default: 9000ms

Reference -

Defined Values

<mode> Integer type, sets TCP/IP application mode


0 Non transparent mode
1 Transparent mode

Examples

AT+CIPMODE=?
+CIPMODE: (0-1)

OK
AT+CIPMODE?
+CIPMODE: 0

www.simcom.com 302 / 483


A76XX Series_AT Command Manual_V1.04

OK
AT+CIPMODE=1
OK
AT+CIPMODE
OK

NOTE

When you want to use transparent mode to transmit data, you should set AT+CIPMODE=1 before
AT+NETOPEN.

AT+CIPSENDMODE Set Sending Mode

AT+CIPSENDMODE is used to select sending mode when service type is "TCP".


If set <mode> to 1, when sending data by AT+CIPSEND, the URC "+CIPSEND:
<link_num>,<reqSendLength>,<cnfSendLength>" will not be returned until module receives the server’s
ACK message to the sent data last time.
If set <mode> to 0, the URC "+CIPSEND: <link_num>,<reqSendLength>,<cnfSendLength>" will be
returned If the data has been sent to module’s internal TCP/IP protocol stack. In this case, the module
doesn’t need to wait for the server’s ACK message.
The default mode is sending without waiting peer TCP ACK mode.

AT+CIPSENDMODE Set Sending Mode


Response
Test Command +CIPSENDMODE: (0-1)
AT+CIPSENDMODE=?
OK
Response
Read Command +CIPSENDMODE: <mode>
AT+CIPSENDMODE?
OK
Response
1)If the parameter is correct, response:
Write Command
OK
AT+CIPSENDMODE=<mode>
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time default: 9000ms

Reference -

www.simcom.com 303 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<mode> Integer type, sets sending mode


0 sending without waiting peer TCP ACK mode
1 sending wait peer TCP ACK mode

Examples

AT+CIPSENDMODE=?
+CIPSENDMODE: (0-1)

OK
AT+CIPSENDMODE=1
OK
AT+CIPSENDMODE?
+CIPSENDMODE: 1

OK

AT+CIPTIMEOUT Set TCP/IP Timeout Value

AT+CIPTIMEOUT is used to set timeout value for AT+NETOPEN/AT+CIPOPEN/AT+CIPSEND.

AT+CIPTIMEOUT Set TCP/IP Timeout Value


Response
+CIPTIMEOUT:
Read Command
<netopen_timeout>,<cipopen_timeout>,<cipsend_timeout>
AT+CIPTIMEOUT?

OK
Response
Write Command
1)If the parameter is correct, response:
AT+CIPTIMEOUT=[<netopen_ti
OK
meout>][,[<cipopen_timeout>][,
2)
[<cipsend_timeout>]]]
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time default: 9000ms

Reference -

www.simcom.com 304 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<netopen_timeout> Integer type, timeout value for AT+NETOPEN.


default is120000ms. Range is 3000ms-120000ms.
<cipopen_timeout> Integer type, timeout value for AT+CIPOPEN.
default is120000ms. Range is 3000ms-120000ms.
<cipsend_timeout> Integer type, timeout value for AT+CIPSEND.
default is120000ms. Range is 3000ms-120000ms.

Examples

AT+CIPTIMEOUT?
+CIPTIMEOUT: 120000,120000,120000

OK
AT+CIPTIMEOUT=3000,3000,3000
OK

AT+CIPCCFG Configure Parameters of Socket

AT+CIPCCFG is used to configure parameters of socket.

AT+CIPCCFG Configure Parameters of Socket


Response
Test Command +CIPCCFG: (0-10),(0-1000),(0),(0-1),(0-1),(0-1),(500-120000)
AT+CIPCCFG=?
OK
Response
+CIPCCFG:
Read Command <NmRetry>,<DelayTm>,<Ack>,<errMode>,<Header-Type>,<As
AT+CIPCCFG? yncMode>,<TimeoutVal>

OK
Write Command Response
AT+CIPCCFG=[<NmRetry>][,[< 1)If the parameter is correct, response:
DelayTm>][,[<Ack>][,[<errMode OK
>][,]<HeaderType>][,[[<AsyncM 2)
ode>][,[<TimeoutVal>]]]]]]]] ERROR
Response
Execute Command
Set default value:
AT+CIPCCFG
OK

www.simcom.com 305 / 483


A76XX Series_AT Command Manual_V1.04

Parameter Saving Mode NO_SAVE


Max Response Time default: 9000ms
Reference -

Defined Values

<NmRetry> Integer type, number of retransmission to be made for an IP


packet. Range is 0-10. The default value is 10.
<DelayTm> Integer type, number of milliseconds to delay to output data of
Receiving. Range is 0-1000. The default value is 0.
<Ack> Integer type, it can only be set to 0. It’s used to be compatible with
old TCP/IP command set.
<errMode> Integer type, sets mode of reporting <err_info>, default value is 1.
0 error result code with numeric values
1 error result code with string values
<HeaderType> Integer type, select which data header is used when receiving
data, it only takes effect in multi-client mode. Default value is 0.
0 add data header, the format is "+IPD<data length>"
1 add data header, the format is "+RECEIVE,<link num>,<data
length>"
<AsyncMode> Integer type, range is 0-1. Default value is 0.
It’s used to be compatible with old TCP/IP command set.
<TimeoutVal> Integer type, set the minimum retransmission timeout value for
TCP connection. Range is 500ms-120000ms. Default is 500ms.

Examples

AT+CIPCCFG=?
+CIPCCFG: (0-10),(0-1000),(0),(0-1),(0-1),(0-1),(500-120000)

OK
AT+CIPCCFG?
+CIPCCFG: 10,0,0,1,0,0,500

OK
AT+CIPCCFG=2
OK
AT+CIPCCFG
OK

www.simcom.com 306 / 483


A76XX Series_AT Command Manual_V1.04

AT+SERVERSTART Startup TCP Sever

AT+SERVERSTART is used to startup a TCP server, and the server can receive the request of TCP client.
After the command executes successfully, an unsolicited result code is returned when a client tries to
connect with module and module accepts request. The unsolicited result code is+CLIENT:
<link_num>,<server_index>,<client_IP>:<port>.

AT+SERVERSTART Startup TCP Sever


Response
Test Command +SERVERSTART: (0-65535),(0-3)
AT+SERVERSTART=?
OK
Response
1)If the PDP context has not been activated successfully,
response:
+CIPERROR: <err>

ERROR
Read Command
AT+SERVERSTART? 2)If there exists opened server, response:
[+SERVERSTART: <server_index>,<port>
…]

OK
3)Others:
ERROR
Response
1)If there is no error, response:
OK
2)If the PDP context has not been activated, or the server
Write Command identified by <server_index> has been opened, or the parameter
AT+SERVERSTART=<port>,<se is not correct, or other errors, response:
rver_index>[,<backlog>] +CIPERROR: <err>

ERROR
3)Others:
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time default: 9000ms
Reference -

Defined Values

www.simcom.com 307 / 483


A76XX Series_AT Command Manual_V1.04

<port> Integer type, identifies the listening port of module when used as a
TCP server. Range is 0-65535.
<server_index> Integer type, the TCP server index, range is 0-3.
<backlog> Integer type, the maximum connections can be queued in listening
queue. Range is 1-3. Default is 3.

Examples

AT+SERVERSTART=?
+SERVERSTART: (0-65535),(0-3)

OK
AT+SERVERSTART?
OK
AT+SERVERSTART=8080,0
OK

AT+SERVERSTOP Stop TCP Sever

AT+SERVERSTOP is used to stop TCP server. Before stopping a TCP server, all sockets <server_index>
of which equals to the closing TCP server index must be closed first.

AT+SERVERSTOP Stop TCP Sever


Response
1)If there exists open connection with the server identified by
<server_index>, or the server identified by <server_index> has not
been opened, or the parameter is incorrect, response:
+SERVERSTOP: <server_index>,<err>

ERROR
2)If the server socket is closed immediately, response:
Write Command
+SERVERSTOP: <server_index>,0
AT+SERVERSTOP=<server_ind
ex>
OK
(In general, the result is shown as below.)
3)If the server socket starts to close, response:
OK

+SERVERSTOP: <server_index>,<err>
4)Others:
ERROR

www.simcom.com 308 / 483


A76XX Series_AT Command Manual_V1.04

Parameter Saving Mode NO_SAVE


Max Response Time default: 9000ms
Reference -

Defined Values

<server_index> Integer type, the TCP server index, range is 0-3.


<err> Integer type, the result of operation.
0 is success, other value is failure, please refer to Chapter 15.3.2 for details

Examples

AT+SERVERSTOP=0
OK

+SERVERSTOP: 0,0

AT+CIPACK Query TCP Connection Data Transmitting Status

AT+CIPACK is used to query TCP connection data transmitting status.

AT+CIPACK Query Connection Data Transmitting State


Response
Test Command +CIPACK: (range of supported <link_num>s)
AT+CIPACK=?
OK
Response
1)If the PDP context has not been activated, or the connection
identified by <link_num> has not been established, abnormally closed,
or the parameter is incorrect, or other errors, response:
+IP ERROR: <err_info>
Write Command
AT+CIPACK=<link_num> ERROR
2)If the connection has been established, and the service type is
"TCP", response:
+CIPACK: <sent_data_size>,<ack_data_size>,<recv_data_size>

OK
Parameter Saving Mode NO_SAVE
Max Response Time default: 9000ms
www.simcom.com 309 / 483
A76XX Series_AT Command Manual_V1.04

Reference -

Defined Values

<link_num> Integer type, identifies a connection. Range is 0-9.


<sent_data_size> Integer type, the total length of sent data
<ack_data_size> Integer type, the total length of acknowledged data.
<recv_data_size> Integer type, the total length of received data
<err> Integer type, the result of operation.
0 is success, other value is failure, please refer to Chapter 15.3.2 for details
<err_info> String type, displays the cause of occurring error, please refer to Chapter 3
for details.

Examples

AT+CIPACK=?
+CIPACK: (0-9)

OK
AT+CIPACK=0
+CIPACK: 10,10,5

OK

AT+CDNSGIP Query the IP Address of Given Domain Name

AT+CDNSGIP is used to query the IP address of given domain name.

AT+CDNSGIP Query the IP Address of Given Domain Name


Test Command Response
AT+CDNSGIP=? OK
Response
1)If the given domain name has related IP, response:
+CDNSGIP: 1,<domain name>,<IP address>
Write Command
AT+CDNSGIP=<domain name> OK
2)If the given name has no related IP, response:
+CDNSGIP: 0,<dns error code>

www.simcom.com 310 / 483


A76XX Series_AT Command Manual_V1.04

ERROR
3)Others:
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time default: 6s

Reference -

Defined Values

<domain name> String type (string should be included in quotation marks), indicates the
domain name. The maximum length of domain name is 254.
Valid characters allowed in the domain name area include a-z, A-Z, 0-9,
"-" (hyphen)and ".". A domain name is made up of one label name or
more label names separated by "." (eg: AT+CDNSGIP="aa.bb.cc").
For label names separated by ".", length of each label must be no more
than 63 characters. The beginning character of the domain name and of
labels should be an alphanumeric character.
<IP address> String type, indicates the IP address corresponding to the domain name.
<dns error code> Integer type, indicates the error code.
10 DNS GENERAL ERROR

Examples

AT+CDNSGIP=?
OK
AT+CDNSGIP="www.baidu.com"
+CDNSGIP: 1,"www.baidu.com","61.135.169.121"

OK

AT+CSOCKSETPN Set active PDP context's profile

This command sets default active PDP context's profile number and type. When we activate PDP by using
AT+NETOPEN command, we need use the default profile number and type.,and the context of this profile is
set by AT+CGDCONT command.

AT+CSOCKSETPN Set acitve PDP context's profile


Test Command Response

www.simcom.com 311 / 483


A76XX Series_AT Command Manual_V1.04

AT+CSOCKSETPN=? +CSOCKSETPN: 1,(1,5)

OK
Response
Read Command +CSOCKSETPN: <profile_num>,<ip_family>
AT+CSOCKSETPN?
OK
Response
1)If the parameter is correct, response:
Write Command
OK
AT+CSOCKSETPN=<profile_nu
2)If the parameter is wrong,or NETOPEN is already active,
m>,<ip_family>
response:
ERROR
Parameter Saving Mode NO_SAVE
Maximum Response Time default: 9000ms

Reference -

Defined Values

<profile_num> Packet Data Protocol context’s profile number.


Now only 1 is supported for this parameter value.
<ip_family> Packet Data Protocol type
1 IPV4
6 IPV6

NOTE

Modifying the PDP context's profile number is not currently supported; <profile_num> can only be set to
1.
When you want to properties of the PDP context, you should set AT+CSOCKSETPN before
AT+NETOPEN.
If the PDP type you set does not match the PDP type of the same file you set in AT+CGDCONT, this will
render NETOPEN unusable.

Examples

AT+CSOCKSETPN=?
+CSOCKSETPN: 1,(1,5)

OK
www.simcom.com 312 / 483
A76XX Series_AT Command Manual_V1.04

AT+CSOCKSETPN?
+CSOCKSETPN: 0

OK
AT+CSOCKSETPN=1,5
OK

Command Result Codes

Description of <err_info>

The fourth parameter <errMode> of AT+CIPCCFG (TODO)is used to determine how <err_info> is
displayed.
If <errMode> is set to 0, the <err_info> is displayed with numeric value.
If <errMode>is set to 1, the <err_info> is displayed with string value.
The default is displayed with string value.

Numeric Value String Value


0 Connection time out
1 Bind port failed
2 Port overflow
3 Create socket failed
4 Network is already opened
5 Network is already closed
6 No clients connected
7 No active client
8 Network not opened
9 Client index overflow
10 Connection is already created
11 Connection is not created
12 Invalid parameter
13 Operation not supported
14 DNS query failed
15 TCP busy
16 Net close failed for socket opened
17 Sending time out
18 Sending failure for network error

www.simcom.com 313 / 483


A76XX Series_AT Command Manual_V1.04

19 Open failure for network error


20 Server is already listening
21 Operation failed
22 No data

Description of <err>

<err> Description of <err>


0 operation succeeded
1 Network failure
2 Network not opened
3 Wrong parameter
4 Operation not supported
5 Failed to create socket
6 Failed to bind socket
7 TCP server is already listening
8 Busy
9 Sockets opened
10 Timeout
11 DNS parse failed for AT+CIPOPEN
12 Unknown error

Unsolicited Result Codes

URC Description
+CIPEVENT: NETWORK CLOSED UNEXPECTEDLY Network is closed for network error(Out of
service, etc). When this event happens,
user’s application needs to check and close
all opened sockets, and then uses
AT+NETCLOSE to release the network
library if AT+NETOPEN? shows the network
library is still opened.
+IPCLOSE: <client_index>,<close_reason> Socket is closed passively.
<client_index> is the link number.
<close_reason>:
0 Closed by local, active

www.simcom.com 314 / 483


A76XX Series_AT Command Manual_V1.04

1 Closed by remote, passive


2 Closed for sending timeout or DTR off
+CLIENT: TCP server accepted a new socket client, the
<link_num>,<server_index>,<client_IP>:<port> index is<link_num>, the TCP server index is
<server_index>. The peer IP address is
<client_IP>, the peer port is <port>.

www.simcom.com 315 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for HTTP(S)


Overview of AT Commands for HTTP(S)

Command Description
AT+HTTPINIT Start HTTP service
AT+HTTPTERM Stop HTTP Service
AT+HTTPPARA Set HTTP Parameters value
AT+HTTPACTION HTTP Method Action
AT+HTTPHEAD Read the HTTP Header Information of Server Response
AT+HTTPREAD Read the response information of HTTP Server
AT+HTTPDATA Input HTTP Data
AT+HTTPPOSTFILE Send HTTP Request to HTTP(S)server by File
AT+HTTPREADFILE Receive HTTP Response Content to a file

Detailed Description of AT Commands for HTTP(S)

AT+HTTPINIT Start HTTP Service

AT+HTTPINIT is used to start HTTP service by activating PDP context. You must execute AT+HTTPINIT
before any other HTTP related operations.

AT+HTTPINIT Start HTTP Service


Response
Test Command
AT+HTTPINIT=?
OK
Response
1)If start HTTP service successfully:
Execute Command
OK
AT+HTTPINIT
2)If failed:
ERROR
Parameter Saving Mode -

www.simcom.com 316 / 483


A76XX Series_AT Command Manual_V1.04

Max Response Time 120000ms


Reference -

Defined Values

<err> The type of error please refer to Section 16.4

Examples

AT+HTTPINIT
OK

AT+HTTPTERM Stop HTTP Service

AT+HTTPTERM is used to stop HTTP service.

AT+HTTPTERM Stop HTTP Service


Response
Test Command
AT+HTTPTERM=?
OK
Response
1)If stop HTTP service successfully:
Execute Command
OK
AT+HTTPTERM
2)If failed:
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Examples

AT+HTTPTERM
OK

www.simcom.com 317 / 483


A76XX Series_AT Command Manual_V1.04

AT+HTTPPARA Set HTTP Parameters value

AT+HTTPPARA is used to set HTTP parameters value. When you want to access to a HTTP server, you
should input <value> like http://’server’/’path’:’tcpPort’. In addition, https://’server’/’path’:’tcpPort’ is used to
access to a HTTPS server.

AT+HTTPPARA Set HTTP Parameters value


Response
Test Command
AT+HTTPPARA=?
OK
Response
1)If parameter format is right:
Write Command
OK
AT+HTTPPARA="URL",<url>
2)If parameter format is not right or other errors occur:
ERROR
Response
Write Command 1)If parameter format is right:
AT+HTTPPARA="CONNECTTO" OK
,<conn_timeout> 2)If parameter format is not right or other errors occur:
ERROR
Response
Write Command 1)If parameter format is right:
AT+HTTPPARA="RECVTO",<re OK
cv_timeout> 2)If parameter format is not right or other errors occur:
ERROR
Response
Write Command 1)If parameter format is right:
AT+HTTPPARA="CONTENT",<c OK
ontent_type> 2)If parameter format is not right or other errors occur:
ERROR
Response
Write Command 1)If parameter format is right:
AT+HTTPPARA="ACCEPT",<ac OK
cept-type> 2)If parameter format is not right or other errors occur:
ERROR
Response
Write Command 1)If parameter format is right:
AT+HTTPPARA="SSLCFG",<ssl OK
cfg_id> 2)If parameter format is not right or other errors occur:
ERROR
Write Command Response
AT+HTTPPARA="USERDATA",< 1)If parameter format is right:
user_data> OK
www.simcom.com 318 / 483
A76XX Series_AT Command Manual_V1.04

2)If parameter format is not right or other errors occur:


ERROR
Response
Write Command
1)If parameter format is right:
AT+HTTPPARA="READMODE",
OK
<readmode>
2)If parameter format is not right or other errors occur:
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<url> URL of network resource.String,start with "http://" or"https://"


a)http://’server’/’path’:’tcpPort’.
b)https://’server’/’path’:’tcpPort’
"server" DNS domain name or IP address
"path" path to a file or directory of a server
"tcpPort" http default value is 80,https default value is 443.(can be
omitted)
<conn_timeout> Timeout for accessing server, Numeric type, range is 20-120s, default
is 120s.
<recv_timeout> Timeout for receiving data from server, Numeric type range is 2s-120s,
default is 20s.
<content_type> This is for HTTP "Content-Type" tag, String type, max length is 256,
and default is "text/plain".
<accept-type> This is for HTTP "Accept-type" tag, String type, max length is 256, and
default is "*/*".
<sslcfg_id> This is setting SSL context id, Numeric type, range is 0-9. Default is
0.Please refer to Chapter 19 of this document.
<user_data> The customized HTTP header information. String type, max length is
256.
<readmode> For HTTPREAD, Numeric type, it can be set to 0 or 1. If set to 1, you
can read the response content data from the same position repeatly.
The limit is that the size of HTTP server response content should be
shorter than 1M.Default is 0.

NOTE

When you want to use content-type mutipart/form-data to transfer data, you should set
AT+HTTPPARA="CONTENT","mutipart/form-data" .And we will construct boundary header.

www.simcom.com 319 / 483


A76XX Series_AT Command Manual_V1.04

Examples

AT+HTTPPARA="URL","http://www.baidu.com"
OK

AT+HTTPACTION HTTP Method Action

AT+HTTPACTION is used to perform a HTTP Method. You can use HTTPACTION to send a get/post
request to a HTTP/HTTPS server.

AT+HTTPACTION HTTP Method Action


Response
Test Command +HTTPACTION: (0-3)
AT+HTTPACTION=?
OK
Response
1)If parameter format is right:
OK

+HTTPACTION: <method>,<statuscode>,<datalen>
Write Command
2)If parameter format is right but server connected unsuccessfully:
AT+HTTPACTION=<method>
OK

+HTTPACTION: <method>,<errcode>,<datalen>
3)If parameter format is not right or other errors occur:
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<method> HTTP method specification:


0 GET
1 POST
2 HEAD
3 DELETE
<statuscode> Please refer to the end of this chapter
<datalen> The length of data received

www.simcom.com 320 / 483


A76XX Series_AT Command Manual_V1.04

Examples

AT+HTTPACTION=?
+HTTPACTION: (0-3)

OK
AT+HTTPACTION=0
OK

+HTTPACTION: 0,200,104220

AT+HTTPHEAD Read the HTTP Header Information of Server Response

AT+HTTPHEAD is used to read the HTTP header information of server response when module receives the
response data from server.

AT+HTTPHEAD Read the HTTP Header Information of Server Response


Response
Test Command
AT+HTTPHEAD=?
OK
Response
1)If read the header information successfully:
+HTTPHEAD: <data_len>
Execute Command
<data>
AT+HTTPHEAD
OK
2)If read failed:
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<dat_len> The length of HTTP header


<data> The header information of HTTP response

Examples

AT+HTTPHEAD
www.simcom.com 321 / 483
A76XX Series_AT Command Manual_V1.04

+HTTPHEAD: 653
HTTP/1.1 200 OK
Content-Type: text/html
Connection: keep-alive
X-Cache: MISS from PDcache-04:opinion.people.com.cn
Date: Tue, 24 Mar 2020 03:12:09 GMT
Powered-By-ChinaCache: HIT from CNC-WB-b-D24
Powered-By-ChinaCache: HIT from CNC-WV-b-D1C
ETag: W/"5b7379f5-57e9"
x-cc-via: CNC-WB-b-D24[H,1], CNC-WV-b-D1C[H,62]
d-cc-upstream: CNC-WV-b-D1C
CACHE: TCP_HIT
Vary: Accept-Encoding
Last-Modified: Wed, 15 Aug 2018 00:55:17 GMT
Expires: Tue, 24 Mar 2020 03:17:09 GMT
x-cc-req-id: f4b9e1793697d1ef2950f530aeec4519
Content-Length: 22505
Age: 0
Accept-Ranges: bytes
Server: nginx
X-Frame-Options: ALLOW-FROM .*
CC_CACHE: TCP_REFRESH_HIT
OK

AT+HTTPREAD Read the response information of HTTP Server

After sending HTTP(S)GET/POST requests, you can retrieve HTTP(S)response information from
HTTP(S)server via UART/USB port by AT+HTTPREAD. When the <datalen> of "+HTTPACTION:
<method>,<statuscode>,<datalen>" is not equal to 0, You can execute
AT+HTTPREAD=<start_offset>,<byte_size> to read out data to port. If parameter <byte_size> is set
greater than the size of data saved in buffer, all data in cache will output to port.

AT+HTTPREAD Read the response information of HTTP Server


Response
Test Command
AT+HTTPREAD=?
OK
Response
1)If check successfully:
Read Command +HTTPREAD: LEN,<len>
AT+HTTPREAD?
OK
2)If failed (no more data other error):

www.simcom.com 322 / 483


A76XX Series_AT Command Manual_V1.04

ERROR
Response
1)If read the response info successfully:
OK

Write Command +HTTPREAD: <data_len>


AT+HTTPREAD=[<start_offset>, <data>
]<byte_size> +HTTPREAD: 0
If <byte_size> is bigger than the data size received, module will
only return actual data size.
2)If read failed:
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<start_offset> The start position of reading


<byte_size> The length of data to read
<datalen> The actual length of read data
<data> Response content from HTTP server
<len> Total size of data saved in buffer.

Examples

AT+HTTPREAD?
+HTTPREAD: LEN,22505

OK
AT+HTTPREAD=0,500
OK

+HTTPREAD: 500
\0\0\0\0\0\0\0\0\0\0\0\0\0\0<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml">
<head>
<meta http-equiv="content-type" content="text/html;charset=GB2312"/>
<meta http-equiv="Content-Language" content="utf-8" />
<meta content="all" name="robots" />
<title>人民日报钟声:牢记历史是为了更好开创未来--观点--人民网 </title>
<meta name="keywords" content="" />
www.simcom.com 323 / 483
A76XX Series_AT Command Manual_V1.04

<meta name="description" content=" 日方应在正确对待历史?


+HTTPREAD: 0

NOTE

The response content received from server will be saved in cache, and would not be cleaned up by
AT+HTTPREAD.
Due to the max size of protocol stack is 64K bytes(the CAT4 module is 10K bytes), when the total size
of the data from server is bigger than that and ‘READMODE’ is 0, you should read the data quickly, or
you will fail to read it.

AT+HTTPDATA Input HTTP Data

You can use AT+HTTPDATA to input data to post when you send a HTTP/HTTPS POST request.

AT+HTTPDATA Input HTTP Data


Response
Test Command
AT+HTTPDATA=?
OK
Response
1)if parameter format is right:
DOWNLOAD
<input data here>
Write Command When the total size of the inputted data reaches <size>, TA will
AT+HTTPDATA=<size>,<time> report the following code. Otherwise, the serial port will be
blocked.
OK
2)If parameter format is wrong or other errors occur:
ERROR
Parameter Saving Mode
Max Response Time
Reference

Defined Values

<size> Size in bytes of the data to post. range is 1- 153600 (bytes)


<time> Maximum time in seconds to input data.range is 10-65535

www.simcom.com 324 / 483


A76XX Series_AT Command Manual_V1.04

Examples

AT+HTTPDATA=18,1000
DOWNLOAD
Message=helloworld
OK

AT+HTTPPOSTFILE Send HTTP Request to HTTP(S)server by File

You also can send HTTP request in a file via AT+HTTPPOSTFILE command. The URL must be set by
AT+HTTPPARA before executing AT+HTTPPOSTFILE command. The parameter <path> can be used to
set the file directory. When modem has received response from HTTP server, it will report the following
URC:
+HTTPPOSTFILE: <httpstatuscode>,<content_length>

AT+HTTPPOSTFILE Send HTTP Request to HTTP(S)server by File


Response
Test Command +HTTPPOSTFILE: <filename>[,(1-2)[,(0-3)[,(0-1)]]]
AT+HTTPPOSTFILE=?
OK
Response
1)if parameter format is right and server connected successfully:
a)if parameter <method> is valid:
OK

+HTTPPOSTFILE: <method>,<statuscode>,<content_len>
b)if parameter <method> is ignored:
OK

Write Command
+HTTPPOSTFILE: <statuscode>,<content_len>
AT+HTTPPOSTFILE=<filename>
2)if parameter format is right but server connected unsuccessfully:
[,<path>[,<method>[,<send_hea
a)if parameter <method> is valid:
der>]]]
OK

+HTTPPOSTFILE: <method>,<errcode>,0
b)if parameter <method> is ignored:
OK

+HTTPPOSTFILE: <errcode>,0
3)if parameter format is not right or any other error occurs:
ERROR

www.simcom.com 325 / 483


A76XX Series_AT Command Manual_V1.04

Parameter Saving Mode


Max Response Time
Reference

Defined Values

<filename> String type, filename, the max length is 112.unit:byte.


<path> The directory where the sent file saved. Numeric type, range is 1-2
1 C:/ (local storage)
2 D:/(sd card)
<method> HTTP method specification:
0 GET
1 POST
2 HEAD
3 DELETE
If this value is not provided, it is same to the value described in the
post file.
<send_header> Send file as HTTP header and Body or Only as Body. Numeric type,
the range is 0-1, the default is 0.
0 Send file as HTTP header and body
1 Send file as Body

Examples

AT+HTTPPOSTFILE=?
+HTTPPOSTFILE: <filename>[,(1-2)[,(0-3)[,(0-1)]]]

OK
AT+HTTPPOSTFILE="getbaidu.txt",1
OK

+HTTPPOSTFILE: 200,14615
AT+HTTPPOSTFILE="getbaidu.txt",1,1,1
OK

+HTTPPOSTFILE: 1,200,14615

AT+HTTPREADFILE Receive HTTP Response Content to a file

After execute AT+HTTPACTION/AT+HTTPOSTFILE command. You can receive the HTTP server response

www.simcom.com 326 / 483


A76XX Series_AT Command Manual_V1.04

content to a file via AT+HTTPREADFILE.


Before AT+HTTPREADFILE executed, "+HTTPACTION: <method>,<httpstatuscode>,<content_len>" or
"+HTTPPOSTFILE: <httpsatuscode>,<content_len>" must be received. The parameter <path> can be used
to set the directory where to save the file. If omit parameter <path>, the file will be save to local storage.

AT+HTTPREADFILE Receive HTTP Response Content to a File


Response
Test Command +HTTPREADFILE: <filename>[,(1-2)]
AT+HTTPREADFILE=?
OK
Response
1)if parameter format is right:
OK

Write Command +HTTPREADFILE: <errcode>


AT+HTTPREADFILE=<filename 2)if failed:
>[,<path>] OK

+HTTPREADFILE: <errcode>
3)if parameter format is not right or any other error occurs:
ERROR
Parameter Saving Mode
Max Response Time
Reference

Defined Values

<filename> String type, filename, the max length is 112.unit:byte.


<path> The directory where the read file saved. Numeric type, range is 1-2.
1 C:/(local storage)
2 D:/(sd card)

Examples

AT+HTTPREADFILE=?
+HTTPREADFILE: <filename>[,(1-2)]

OK
AT+HTTPREADFILE="readbaidu.dat"
OK

+HTTPREADFILE: 0

www.simcom.com 327 / 483


A76XX Series_AT Command Manual_V1.04

Command Result Codes

Description of <statuscode>

<statuscode> Description
100 Continue
101 Switching Protocols
200 OK
201 Created
202 Accepted
203 Non-Authoritative Information
204 No Content
205 Reset Content
206 Partial Content
300 Multiple Choices
301 Moved Permanently
302 Found
303 See Other
304 Not Modified
305 Use Proxy
307 Temporary Redirect
400 Bad Request
401 Unauthorized
402 Payment Required
403 Forbidden
404 Not Found
405 Method Not Allowed
406 Not Acceptable
407 Proxy Authentication Required
408 Request Timeout
409 Conflict
410 Gone
411 Length Required
412 Precondition Failed
413 Request Entity Too Large
414 Request-URI Too Large

www.simcom.com 328 / 483


A76XX Series_AT Command Manual_V1.04

415 Unsupported Media Type


416 Requested range not satisfiable
417 Expectation Failed
500 Internal Server Error
501 Not Implemented
502 Bad Gateway
503 Service Unavailable
504 Gateway timeout
505 HTTP Version not supported
600 Not HTTP PDU
601 Network Error
602 No memory
603 DNS Error
604 Stack Busy

Description of <errcode>

<errcode> Meaning
0 Success
701 Alert state
702 Unknown error
703 Busy
704 Connection closed error
705 Timeout
706 Receive/send socket data failed
707 File not exists or other memory error
708 Invalid parameter
709 Network error
710 start a new ssl session failed
711 Wrong state
712 Failed to create socket
713 Get DNS failed
714 Connect socket failed
715 Handshake failed
716 Close socket failed
717 No network error
718 Send data timeout
719 CA missed

www.simcom.com 329 / 483


A76XX Series_AT Command Manual_V1.04

Unsolicited Result Codes

URC Description
It’s a notification message. While received, it means the
+HTTP_PEER_CLOSED
connection has been closed by server.
+HTTP_NONET_EVENT It’s a notification message. While received, it means now the
network is unavailable.

www.simcom.com 330 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for FTP(S)


Overview of AT Commands for FTP(S)

Command Description
AT+CFTPSSTART Start FTP(S)service
AT+CFTPSSTOP Stop FTP(S)Service
AT+CFTPSLOGIN Login to a FTP(S)server
AT+CFTPSLOGOUT Logout a FTP(S)server
AT+CFTPSLIST List the items in the directory on FTP(S)server
AT+CFTPSMKD Create a new directory on FTP(S)server
AT+CFTPSRMD Delete a directory on FTP(S)server
AT+CFTPSCWD Change the current directory on FTP(S)server
AT+CFTPSPWD Get the current directory on FTP(S)server
AT+CFTPSDELE Delete a file on FTP(S)server
AT+CFTPSGETFILE Download a file from FTP(S)server to module
AT+CFTPSPUTFILE Upload a file from module to FTP(S)server
AT+CFTPSGET Get a file from FTP(S)server to serial port
AT+CFTPSPUT Put a file to FTP(S)server through serial port
AT+CFTPSSIZE Get the file size on FTP(S)server
AT+CFTPSSINGLEIP Set FTP(S)data socket address type
AT+CFTPSTYPE Set the transfer type on FTP(S)server
AT+CFTPSSLCFG Set the SSL context id for FTPS session

Detailed Description of AT Commands for FTP(S)

AT+CFTPSSTART Start FTP(S)service

AT+CFTPSSTART is used to start FTP(S)service by activating PDP context. You must execute
AT+CFTPSSTART before any other FTP(S)related operations.

www.simcom.com 331 / 483


A76XX Series_AT Command Manual_V1.04

AT+CFTPSSTART Start FTP(S)service


Response
Test Command
AT+CFTPSSTART=?
OK
Response
1)
OK

+CFTPSSTART: 0
Execution Command
2)
AT+CFTPSSTART
OK

+CFTPSSTART: <errcode>
3)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

Defined Values

<errcode> The result of start FTP(S)service, 0 is success, others are failure.


Please refer to errcode list.

Examples

AT+CFTPSSTART
OK

+CFTPSSTART: 0

AT+CFTPSSTOP Stop FTP(S)Service

AT+CFTPSSTOP is used to stop FTP(S)service by deactivating PDP context When you are no longer using
the FTP(S)service, use this command.

AT+CFTPSSTOP Stop FTP(S)Service


Response
Test Command
AT+CFTPSSTOP=?
OK
www.simcom.com 332 / 483
A76XX Series_AT Command Manual_V1.04

Response
1)
OK

+CFTPSSTOP: 0
Execution Command
2)
AT+CFTPSSTOP
OK

+CFTPSSTOP: <errcode>
3)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

Defined Values

<errcode> The result of stop FTP(S)service, 0 is success, others are failure.


Please refer to errcode list.

Examples

AT+CFTPSSTOP
OK

+CFTPSSTOP: 0

AT+CFTPSLOGIN Login to a FTP(S)server

AT+CFTPSLOGIN is used to login to a FTP(S)server, you can login to a FTP server by set parameter
<server_type> to 0, login to an implicit FTPS server by set <server_type> to 3 and login to an explicit FTPS
server by set <server_type> to1 or 2. About <sever_type>, more details please refer to Defined Values
<server_type>.

AT+CFTPSLOGIN Login to a FTP(S)server


Response
+CFTPSLOGIN:
Test Command
"ADDRESS",(1-65535),"USERNAME","PASSWORD"[,(0-3)]
AT+CFTPSLOGIN=?

OK

www.simcom.com 333 / 483


A76XX Series_AT Command Manual_V1.04

Response
1)
OK

Write Command
+CFTPSLOGIN: 0
AT+CFTPSLOGIN=<host>,<port
2)
>,<username>,<password>[<se
OK
rver_type>]

+CFTPSLOGIN: <errcode>
3)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

Defined Values

<host> Host address, string type, maximum length is 128


<port> The host listening port for FTP(S), the range is from 1 to 65535
<username> FTP(S)user name, string type, maximum length is 128
<password> The user password, string type, maximum length is 128
<servet_type> FTP(S)server type, numeric, from 0-3, default is 3
0 FTP server.
1 Explicit FTPS server with AUTH SSL.
2 Explicit FTPS server with AUTH TLS.
3 Implicit FTPS server.
<errcode> The result code of the FTP/FTPS login. 0 is success. Others are
failure, please refer to chapter 17.3.

Examples

AT+CFTPSLOGIN=?
+CFTPSLOGIN:
"ADDRESS",(1-65535),"USERNAME","PASSWORD"[,(0-3)]

OK
AT+CFTPSLOGIN="serveraddr",21,"username","password",0
OK

+CFTPSLOGIN: 0

www.simcom.com 334 / 483


A76XX Series_AT Command Manual_V1.04

AT+CFTPSLOGOUT Logout a FTP(S)server

AT+CFTPSLOGOUT is used to logout a FTP(S)sever, make sure you login a FTP(S)sever before you
execute AT+CFTPSLOGOUT command.

AT+CFTPSLOGOUT Logout a FTP(S)server


Test Command Response
AT+CFTPSLOGOUT=? OK
Response
1)
OK

+CFTPSLOGOUT: <0>
Execute Command
2)
AT+CFTPSLOGOUT
OK

+CFTPSLOGOUT: <errcode>
3)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

Defined Values

<errcode> The result code of the FTP/FTPS logout. 0 is success. Others are
failure, please refer to chapter 17.3.

Examples

AT+CFTPSLOGOUT=?
OK
AT+CFTPSLOGOUT
OK

+CFTPSLOGOUT: 0

NOTE

When you want to stop the FTP(S)service,please use AT+CFTPSLOGOUT to log out of the
FTP(S)server,then use AT+CFTPSSTOP to stop FTP,if you only use AT+CFTPSSTOP,it will report

www.simcom.com 335 / 483


A76XX Series_AT Command Manual_V1.04

ERROR.

AT+CFTPSLIST List the items in the directory on FTP(S)server

This command is used to list the items in the specified directory on FTP(S)server. Module will output the
items to serial port when list items successfully. Make sure that you have login to FTP(S)server
successfully.

AT+CFTPSLIST List the items in the directory on FTP(S)server


Response
Test Command
AT+CFTPSLIST=?
OK
Response
1)
OK

+CFTPSLIST: DATA,<len>

Write Command
+CFTPSLIST: 0
AT+CFTPSLIST=<dir>
2)
OK

+CFTPSLIST: <errcode>
3)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

Defined Values

<dir> The directory to be created, string type, maximum length is 112.


<errcode> The result of create directory, 0 is success, others are failure, please
refer to chapter 17.3
<len> The server All files and related information in the directory.

Examples

www.simcom.com 336 / 483


A76XX Series_AT Command Manual_V1.04

AT+CFTPSLIST="/"
OK

+CFTPSLIST: DATA,175
-rw-r--r-- 1 ftp ftp 121 Mar 11 16:24 124.txt
drwxr-xr-x 1 ftp ftp 0 Jan 13 2020
TEST113
drwxr-xr-x 1 ftp ftp 0 Jan 19 2020
TEST1155

+CFTPSLIST: 0

AT+CFTPSMKD Create a new directory on FTP(S)server

AT+CFTPSMKD is used to create a new directory on a FTP(S)server. Please make sure login to the
FTP(S)server successfully before create a directory.

AT+CFTPSMKD Create a new directory on FTP(S)server


Response
Test Command +CFTPSMKD: "DIR"
AT+CFTPSMKD=?
OK
Response
1)
OK

+CFTPSMKD: 0
Write Command
2)
AT+CFTPSMKD=<dir>
OK

+CFTPSMKD: <errcode>
3)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

Defined Values

<dir> The directory to be created, string type, maximum length is 112.


<errcode> The result of create directory, 0 is success, others are failure, please
www.simcom.com 337 / 483
A76XX Series_AT Command Manual_V1.04

refer to chapter 17.3

Examples

AT+CFTPSMKD=?
+CFTPSMKD: "DIR"

OK
AT+CFTPSMKD="test"
OK

+CFTPSMKD: 0

AT+CFTPSRMD Delete a directory on FTP(S)server

AT+CFTPSRMD is used to delete a directory on FTP(S)server, please make sure login to the FTP(S)server
successfully before delete a directory.

AT+CFTPSRMD Delete a directory on FTP(S)server


Response
Test Command +CFTPSRMD: "DIR"
AT+CFTPSRMD=?
OK
Response
1)
OK

+CFTPSRMD: 0
Write Command
2)
AT+CFTPSRMD=<dir>
OK

+CFTPSRMD: <errcode>
3)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

Defined Values

www.simcom.com 338 / 483


A76XX Series_AT Command Manual_V1.04

<dir> The directory to be deleted, string type, maximum length is 112.


<errcode> The result of create directory, 0 is success, others are failure, please
refer to chapter 17.3

Examples

AT+CFTPSRMD=?
+CFTPSRMD: "DIR"

OK
AT+CFTPSRMD="test"
OK

+CFTPSRMD: 0

AT+CFTPSCWD Change the current directory on FTP(S)server

You can use this command to change the current directory on FTP(S)sever. Make sure you have login to
FTP(S)server successfully before AT+CFTPSCWD

AT+CFTPSCWD Change the current directory on FTP(S)server


Response
Test Command +CFTPSCWD: "DIR"
AT+CFTPSCWD=?
OK
Response
1)
OK

+CFTPSCWD: 0
Write Command
2)
AT+CFTPSCWD=<dir>
OK

+CFTPSCWD: <errcode>
3)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

www.simcom.com 339 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<dir> The directory to be changed, string type, maximum length is 112.


<errcode> The result of create directory, 0 is success, others are failure, please
refer to chapter 17.3

Examples

AT+CFTPSCWD=?
+CFTPSCWD: "DIR"

OK
AT+CFTPSCWD="test"
OK

+CFTPSCWD: 0

AT+CFTPSPWD Get the current directory on FTP(S)server

This command is used to get the current directory on FTPS server. Before AT+CFTPSPWD, please make
sure you have login to FTP(S)server successfully

AT+CFTPSPWD Get the current directory on FTP(S)server


Response
Test Command +CFTPSPWD:
AT+CFTPSPWD=?
OK
Response
1)
OK

+CFTPSPWD: <dir>
Execute Command
2)
AT+CFTPSPWD
+CFTPSPWD: <errcode>

ERROR
3)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

www.simcom.com 340 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<dir> The directory to be got, string type, maximum length is 112.


<errcode> The result of create directory, 0 is success, others are failure, please
refer to chapter 17.3

Examples

AT+CFTPSPWD
OK

+CFTPSPWD: 0

AT+CFTPSDELE Delete a file on FTP(S)server

You can use AT+CFTPSDELE delete a file on FTP(S)server, please make sure login to the FTP(S)server
successfully before delete a file.

AT+CFTPSDELE Delete a file on FTP(S)server


Response
Test Command +CFTPSDELE: "FILENAME"
AT+CFTPSDELE=?
OK
Response
1)
OK

+CFTPSDELE: 0
Write Command
2)
AT+CFTPSDELE=<filename>
OK

+CFTPSDELE: <errcode>
3)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

www.simcom.com 341 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<filename> The name of the file to be deleted. String type, the maximum length is
112
<errcode> The result of create directory, 0 is success, others are failure, please
refer to chapter 17.3

Examples

AT+CFTPSDELE=?
+CFTPSDELE="FILENAME"

OK
AT+CFTPSDELE="testfile"
OK

+CFTPSDELE: 0

AT+CFTPSGETFILE Download a file from FTP(S)server to module

You can download a file from FTP(S)server to module, by setting parameter <dir>, you can select the
directory where to save the downloaded file. Default the downloaded file will be saved to local storage.
Make sure that you have login to FTP(S)server successfully before AT+CFTPSGETFILE.

AT+CFTPSGETFILE Download a file from FTP(S)server to module


Response
Test Command +CFTPSGETFILE: "FILEPATH"[,(1-2)]
AT+CFTPSGETFILE=?
OK
Response
1)
OK

Write Command +CFTPSGETFILE: 0


AT+CFTPSGETFILE=<filepath>[ 2)
,<dir>] OK

+CFTPSGETFILE: <errcode>
3)
ERROR
Parameter Saving Mode NO_SAVE

www.simcom.com 342 / 483


A76XX Series_AT Command Manual_V1.04

Max Response Time 9000ms


Reference

Defined Values

<filepath> The remote file path. String type, maximum length is 112
<dir> The directory to save the downloaded file. Numeric type, range is 1-2,
default is 1(local storage)
1 C:/(local storage)
2 D:/(sd card)
<errcode> The result code of download file from FTP(s)server. 0 is success,
others are failure, please refer to chapter 17.3.

Examples

AT+CFTPSGETFILE=?
+CFTPSGETFILE: "FILEPATH"[,(1-2)]

OK
AT+CFTPSGETFILE="test.txt",1
OK

+CFTPSGETFILE: 0

AT+CFTPSPUTFILE Upload a file from module to FTP(S)server

You can use this command to upload a file to FTP(S)server from module. By setting parameter <dir> you
can select the directory that contains the file to be uploaded. Make sure that you have login to the
FTP(S)server successfully before AT+CFTPSPUTFILE.

AT+CFTPSPUTFILE Upload a file from module to FTP(S)server


Response
+CFTPSPUTFILE: "FILEPATH",(range of supported
Test Command
<dir>s),(range of supported <rest_size>s)
AT+CFTPSPUTFILE=?

OK
Response
Write Command
1)
AT+CFTPSPUTFILE=<filepath>[
OK
,<dir>[,<rest_size>]]

www.simcom.com 343 / 483


A76XX Series_AT Command Manual_V1.04

+CFTPSPUTFILE: 0
2)
OK

+CFTPSPUTFILE: <errcode>
3)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

Defined Values

<filepath> The remote file path. String type, maximum length is 112
<dir> The directory to save the downloaded file. Numeric type, range is 1-2,
default is 1(local storage)
1 C:/(local storage)
2 D:/(sd card)
<rest_size> The value for FTP "REST" command which is used for broken transfer
when transferring failed last time. If the file is complete, the file length
is not increased. Numeric type, the range is from 0 to 2147483647.
<errcode> The result code of download file from FTP(s)server. 0 is success,
others are failure, please refer to chapter 17.3.

Examples

AT+CFTPSPUTFILE=?
+CFTPSPUTFILE: "FILEPATH",(1-2),(0-2147483647)

OK
AT+CFTPSPUTFILE="test.txt",1
OK

+CFTPSPUTFILE: 0

AT+CFTPSGET Get a file from FTP(S)server to serial port

You can use this command to get a file from FTP(S)server to serial port.

AT+CFTPSGET Get a file from FTP(S)server to serial port


www.simcom.com 344 / 483
A76XX Series_AT Command Manual_V1.04

Response
Test Command +CFTPSGET: "FILEPATH"[,<rest_size>]
AT+CFTPSGET=?
OK
Response
1)
OK

+CFTPSGET:DATA,<len>

Write Command +CFTPSGET:DATA,<len>
AT+CFTPSGET=<filepath>[,<re …
st_size>] +CFTPSGET:0
2)
OK

+CFTPSGET: <errcode>
3)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

Defined Values

<filepath> The remote file path. String type, maximum length is 112.
<rest_size> The value for FTP "REST" command which is used for broken transfer
when transferring failed last time. Numeric type, the range is from 0 to
2147483647
<errcode> The result code of download file from FTP(s)server. 0 is success,
others are failure, please refer to chapter 17.3.

Examples

AT+CFTPSGET=?
+CFTPSGET: "FILEPATH"[,<rest_size>]

OK
AT+CFTPSGET="test.txt"
OK

+CFTPSGET: DATA,3
321

www.simcom.com 345 / 483


A76XX Series_AT Command Manual_V1.04

+CFTPSGET: 0

AT+CFTPSPUT Put a file to FTP(S)server through serial port

You can put a file to FTP(S)server through serial port. Make sure that you have login to FTP(S)server
successfully.

AT+CFTPSPUT Put a file to FTP(S)server through serial port


Response
Test Command +CFTPSPUT: "FILEPATH"[,<data_len>[,<rest_size>]]
AT+CFTPSPUT=?
OK
Response
1)if upload file through serial port successfully:
OK

+CFTPSPUT: 0
2)if failed before input data:
Write Command ERROR
AT+CFTPSPUT=<filepath>[,<dat
a_len>[,<rest_size>]] +CFTPSPUT: <errcode>
3)if failed after input data:
OK

+CFTPSPUT: <errcode>
4)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 600000ms
Reference

Defined Values

<filepath> The remote file path. String type, maximum length is 112.
<data_len> Numeric type, The length of the data to send, the maximum length is
2048.if parameter <data_len> is omitted, Each <Ctrl+Z>character
present in the data flow of serial port when downloading FTP data will
be coded as <ETX><Ctrl+Z>. Each <ETX> character will be coded as
<ETX><ETX>. Single <Ctrl+Z> means end of the FTP data. <ETX> is
0x03, and <Ctrl+Z> is 0x1A.
<rest_size> The value for FTP "REST" command which is used for broken transfer
www.simcom.com 346 / 483
A76XX Series_AT Command Manual_V1.04

when transferring failed last time. Numeric type, the range is from 0 to
2147483647
<errcode> The result code of download file from FTP(s)server. 0 is success,
others are failure, please refer to chapter 17.3.

Examples

AT+CFTPSPUT=?
+CFTPSPUT:
"FILEPATH"[,<data_len>[,<rest_size>]]

OK
AT+CFTPSPUT="test.txt",4
>
data
OK

+CFTPSPUT: 0

AT+CFTPSSINGLEIP Set FTP(S)data socket address type

This command is used to set FTPS server data socket IP address type. For some FTP(S)server, it is
needed to set AT+CFTPSSINGLEIP=1.Please make sure to set AT+CFTPSSINGLEIP before
AT+CFTPSLOGIN.

AT+CFTPSSINGLEIP Set FTP(S)data socket address type


Response
Test Command +CFTPSSINGLEIP: (0,1)
AT+CFTPSSINGLEIP=?
OK
+CFTPSSINGLEIP: <singleip>
Read Command
AT+CFTPSSINGLEIP?
OK
Response
Write Command 1)
AT+CFTPSSINGLEIP=<singleip OK
> 2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

www.simcom.com 347 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<singleip> The FTPS data socket IP address type:


0 decided by PORT response from FTPS server
1 the same as the control socket.

Examples

AT+CFTPSSINGLEIP=?
+CFTPSSINGLEIP: (0,1)

OK
AT+CFTPSSINGLEIP?
+CFTPSSINGLEIP: 0

OK
AT+CFTPSSINGLEIP=0
OK

AT+CFTPSSIZE Get the file size on FTP(S)server

You can use this command to get the file size on FTP(S)server. Please make sure you have login to
FTP(S)server before AT+CFTPSSIZE.

AT+CFTPSSIZE Get the file size on FTP(S)server


Response
Test Command +CFTPSSIZE: "FILEPATH"
AT+CFTPSSIZE=?
OK
Response
1)
OK

Write Command
+CFTPSSIZE: <filesize>
AT+CFTPSSIZE=<filepath>
2)
ERROR

+CFTPSSIZE: <errcode>
Parameter Saving Mode NO_SAVE

www.simcom.com 348 / 483


A76XX Series_AT Command Manual_V1.04

Max Response Time 9000ms


Reference

Defined Values

<filepath> The remote file path on FTP(S)server. String type, max length is 112
<filesize> Numeric type, size of the remote file on FTP(S)server
<errcode> The result of set type, 0 is success, others are failure, please refer to
chapter 4

Examples

AT+CFTPSSIZE=?
+CFTPSSIZE: "FILEPATH"

OK
AT+CFTPSSIZE="test"
OK

+CFTPSSIZE: 3

AT+CFTPSTYPE Set the transfer type on FTP(S)server

This command is used to set the transfer type on FTP(S)server, please make sure you have login to
FTP(S)server before AT+CFTPSTYPE.

AT+CFTPSTYPE Set the transfer type on FTP(S)server


Response
Test Command +CFTPSTYPE: (A,I)
AT+CFTPSTYPE=?
OK
+CFTPSTYPE: <type>
Read Command
AT+CFTPSTYPE?
OK
Response
1)
Write Command OK
AT+CFTPSTYPE=<type>
+CFTPSTYPE: 0
2)
www.simcom.com 349 / 483
A76XX Series_AT Command Manual_V1.04

OK

+CFTPSTYPE: <errcode>
3)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

Defined Values

<type> The type of transferring:


A ASCII
I Binary
<errcode> The result of set type, 0 is success, others are failure, please refer to
chapter 17.3

Examples

AT+CFTPSTYPE=?
+CFTPSTYPE: (A,I)

OK
AT+CFTPSTYPE?
+CFTPSTYPE: I

OK
AT+CFTPSTYPE=A
OK

+CFTPSTYPE: 0

AT+CFTPSSLCFG Set the SSL context id for FTPS session

You can use this command to set the SSL context id for FTPS session.

AT+CFTPSSLCFG Set the SSL context id for FTPS session


Response
Test Command
+CFTPSSLCFG: (0,1),(0-9)
AT+CFTPSSLCFG=?

www.simcom.com 350 / 483


A76XX Series_AT Command Manual_V1.04

OK
Response
Write Command 1)
AT+CFTPSSLCFG=<session_id OK
>,<ssl_id> 2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference

Defined Values

<session_id> Numeric type, 0 for control session, 1 for data session.


<ssl_id> Numeric type, SSL context ID during 0-9.

Examples

AT+CFTPSSLCFG=?
+CFTPSSLCFG: (0,1),(0-9)

OK
AT+CFTPSSLCFG=0,1
OK

Command Result Codes

Description of <errcode>

<errcode> Description
0 Success
1 SSL alert
2 Unknown error
3 Busy
4 Connection closed by server
5 Timeout
6 Transfer failed

www.simcom.com 351 / 483


A76XX Series_AT Command Manual_V1.04

7 File not exists or any other memory error


8 Invalid parameter
9 Operation rejected by server
10 Network error
11 State error
12 Failed to parse server name
13 Create socket error
14 Connect socket failed
15 Close socket failed
16 SSL session closed
17 File error, file not exist or other error.
421 Server response connection time out, while received error code 421,
you need do AT+CFTPSLOGOUT to logout server then
AT+CFTPSLOGIN again for further operations.

Unsolicited Result codes

Unsolicited codes Description


+CFTPSNOTIFY: PEER CLOSED When client disconnect passively, URC "+CFTPSNOTIFY:
PEER CLOSED" will be reported, then user need to execute
AT+CFTPSLOGOUT and log in again.

www.simcom.com 352 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for MQTT(S)


Overview of AT Commands for MQTT(S)

Command Description
AT+CMQTTSTART Start MQTT service
AT+CMQTTSTOP Stop MQTT service
AT+CMQTTACCQ Acquire a client
AT+CMQTTREL Release a client
AT+CMQTTSSLCFG Set the SSL context (only for SSL/TLS MQTT)
AT+CMQTTWILLTOPIC Input the topic of will message
AT+CMQTTWILLMSG Input the will message
AT+CMQTTCONNECT Connect to MQTT server
AT+CMQTTDISC Disconnect from server
AT+CMQTTTOPIC Input the topic of publish message
AT+CMQTTPAYLOAD Input the publish message
AT+CMQTTPUB Publish a message to server
AT+CMQTTSUBTOPIC Input the topic of subscribe message
AT+CMQTTSUB Subscribe a message to server
AT+CMQTTUNSUBTOPIC Input the topic of unsubscribe message
AT+CMQTTUNSUB Unsubscribe a message to server
AT+CMQTTCFG Configure the MQTT Context

Detailed Description of AT Commands for MQTT(S)

AT+CMQTTSTART Start MQTT service

AT+CMQTTSTART is used to start MQTT service by activating PDP context. You must execute this
command before any other MQTT related operations.

AT+CMQTTSTART Start MQTT service

www.simcom.com 353 / 483


A76XX Series_AT Command Manual_V1.04

Execute Command Response


AT+CMQTTSTART 1)If start MQTT service successfully:
OK

+CMQTTSTART: 0
2)If failed:
OK

+CMQTTSTART: <errcode>
3)If MQTT service have started successfully and you executed
AT+CMQTTSTART again:
ERROR
Max Response Time 12000ms
Parameter Saving Mode -
Reference

Defined Values

<errcode> The result code, please refer to Chapter 18.3

Examples

AT+CMQTTSTART
OK

+CMQTTSTART: 0

NOTE

AT+CMQTTSTART is used to start MQTT service by activating PDP context. You must execute this
command before any other MQTT related operations.
If you don’t execute AT+CMQTTSTART, the Write/Read Command of any other MQTT will return
ERROR immediately.

AT+CMQTTSTOP Stop MQTT service

AT+CMQTTSTOP is used to stop MQTT service.

www.simcom.com 354 / 483


A76XX Series_AT Command Manual_V1.04

AT+CMQTTSTOP Stop MQTT service


Response
1)If stop MQTT service successfully:
OK

+CMQTTSTOP: 0
Execute Command 2)If failed:
AT+CMQTTSTOP OK

+CMQTTSTOP: <errcode>
3)If MQTT service have stopped successfully and you executed
AT+CMQTTSTOP again:
ERROR
Max Response Time 12000ms
Parameter Saving Mode -
Reference

Defined Values

<errcode> The result code, please refer to chapter 18.3

Examples

AT+CMQTTSTOP
OK

+CMQTTSTOP: 0

NOTE

AT+CMQTTSTOP is used to stop MQTT service. You can execute this command after
AT+CMQTTDISC and AT+CMQTTREL.

AT+CMQTTACCQ Acquire a client

AT+CMQTTACCQ is used to acquire a MQTT client. It must be called before all commands about MQTT
connect and after AT+CMQTTSTART.

www.simcom.com 355 / 483


A76XX Series_AT Command Manual_V1.04

AT+CMQTTACCQ Acquire a client


Response
Test Command +CMQTTACCQ: (0-1),(1-128)[,(0-1)]
AT+CMQTTACCQ=?
OK
Response
+CMQTTACCQ: <client_index>,<clientID>,<server_type>
Read Command
+CMQTTACCQ: <client_index>,<clientID>,<server_type>
AT+CMQTTACCQ?

OK
Response
1)If successfully:
OK
Write Command
2)If failed:
AT+CMQTTACCQ=<client_in
+CMQTTACCQ: <client_index>,<err>
dex>,<clientID>[<server_type
>]
ERROR
3)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<client_index> A numeric parameter that identifies a client. The range of permitted


values is 0 to 1.
<clientID> The UTF-encoded string. It specifies a unique identifier for the client.
The string length is from 1 to 128 bytes.
<server_type> A numeric parameter that identifies the server type. The default value
is 0.
0 MQTT server with TCP
1 MQTT server with SSL/TLS
<errcode> The result code, please refer to chapter 18.3

Examples

AT+CMQTTACCQ=0,"a12mmmm",0
OK
AT+CMQTTACCQ?
+CMQTTACCQ: 0,"a12mmmm",0
+CMQTTACCQ: 1,"",0

www.simcom.com 356 / 483


A76XX Series_AT Command Manual_V1.04

OK
AT+CMQTTACCQ=?
+CMQTTACCQ: (0-1),(1-128)[,(0-1)]

OK

NOTE

AT+CMQTTACCQ is used to acquire a MQTT client. It must be called before all commands about
MQTT connect and after AT+CMQTTSTART.

AT+CMQTTREL Release a client

AT+CMQTTREL is used to release a MQTT client. It must be called after AT+CMQTTDISC and before
AT+CMQTTSTOP.

AT+CMQTTREL Release a client


Response
Test Command +CMQTTREL: (0-1)
AT+CMQTTREL=?
OK
Read Command Response
AT+CMQTTREL? OK
Response
1)If successfully:
OK
Write Command 2)If failed:
AT+CMQTTREL=<client_inde +CMQTTREL: <client_index>,<err>
x>
ERROR
3)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

www.simcom.com 357 / 483


A76XX Series_AT Command Manual_V1.04

<client_index> A numeric parameter that identifies a client. The range of permitted


values is 0 to 1.
<errcode> The result code, please refer to chapter 18.3

Examples

AT+CMQTTREL=?
+CMQTTREL: (0-1)

OK
AT+CMQTTREL=0
OK
AT+CMQTTREL?
OK

NOTE

AT+CMQTTREL is used to release a MQTT client. It must be called after AT+CMQTTDISC and before
AT+CMQTTSTOP.

AT+CMQTTSSLCFG Set the SSL context (only for SSL/TLS MQTT)

AT+CMQTTSSLCFG is used to set the SSL context which to be used in the SSL connection when it will
connect to a SSL/TLS MQTT server. It must be called before AT+CMQTTCONNECT and after
AT+CMQTTSTART. The setting will be cleared after AT+CMQTTCONNECT failed or AT+CMQTTDISC.

AT+CMQTTSSLCFG Set the SSL context (only for SSL/TLS MQTT)


Response
Test Command +CMQTTSSLCFG: (0,1),(0-9)
AT+CMQTTSSLCFG=?
OK
Response
+CMQTTSSLCFG: <session_id>,[<ssl_ctx_index>]
Read Command
+CMQTTSSLCFG: <session_id>,[<ssl_ctx_index>]
AT+CMQTTSSLCFG?

OK
Write Command Response
AT+CMQTTSSLCFG=<sessio 1)If successfully:

www.simcom.com 358 / 483


A76XX Series_AT Command Manual_V1.04

n_id>,<ssl_ctx_index> OK
2)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<session_id> The session_id to operate. It’s from 0 to 1


<ssl_ctx_index> The SSL context ID which will be used in the SSL connection. Refer to
the <ssl_ctx_index> of AT+CSSLCFG

Examples

AT+CMQTTSSLCFG?
+CMQTTSSLCFG: 0,0
+CMQTTSSLCFG: 1,0

OK
AT+CMQTTSSLCFG=?
+CMQTTSSLCFG: (0,1),(0-9)

OK
AT+CMQTTSSLCFG=0,1
OK

AT+CMQTTWILLTOPIC Input the topic of will message

AT+CMQTTWILLTOPIC is used to input the topic of will message.

AT+CMQTTWILLTOPIC Input the topic of will message


Response
Test Command +CMQTTWILLTOPIC: (0-1),(1-1024)
AT+CMQTTWILLTOPIC=?
OK
Write Command Response
AT+CMQTTWILLTOPIC=<clie 1)If successfully:
nt_index>,<req_length> >

www.simcom.com 359 / 483


A76XX Series_AT Command Manual_V1.04

<input data here>


OK
2)If failed:
+CMQTTWILLTOPIC: <client_index>,<err>

ERROR
3)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<client_index> A numeric parameter that identifies a client. The range of permitted


values is 0 to 1.
<req_length> The length of input topic. The will topic should be UTF-encoded string.
The range is from 1 to 1024 bytes.
<err> The result code, please refer to chapter 18.3

Examples

AT+CMQTTWILLTOPIC=0,10
>

OK

AT+CMQTTWILLMSG Input the will message

AT+CMQTTWILLMSG is used to input the message body of will message.

AT+CMQTTWILLMSG Input the will message


Response
Test Command +CMQTTWILLMSG: (0-1),(1-1024),(0-2)
AT+CMQTTWILLMSG=?
OK
Response
Write Command
1)If successfully:
AT+CMQTTWILLMSG=<clien
>
t_index>,<req_length>,<qos>
<input data here>
www.simcom.com 360 / 483
A76XX Series_AT Command Manual_V1.04

OK
2)If failed:
+CMQTTWILLMSG: <client_index>,<err>

ERROR
3)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<client_index> A numeric parameter that identifies a client. The range of permitted


values is 0 to 1.
<req_length> The length of input data. The will message should be UTF-encoded
string. The range is from 1 to 1024 bytes.
<qos> The qos value of the will message. The range is from 0 to 2.

Examples

AT+CMQTTWILLMSG=0,6,1
>
OK

AT+CMQTTCONNECT Connect to MQTT server

AT+CMQTTCONNECT is used to connect to a MQTT server.

AT+CMQTTCONNECT Connect to MQTT server


Response
+CMQTTCONNECT:
Test Command
(0-1),(9-256),(1-64800),(0-1)[,<user_name>,<pass_word>]
AT+CMQTTCONNECT=?

OK
Response
+CMQTTCONNECT:
Read Command
0[,<server_addr>,<keepalive_time>,<clean_session>[,<user_na
AT+CMQTTCONNECT?
me>[,<pass_word>]]]
+CMQTTCONNECT:
www.simcom.com 361 / 483
A76XX Series_AT Command Manual_V1.04

1[,<server_addr>,<keepalive_time>,<clean_session>[,<user_na
me>[,<pass_word>]]]

OK
Response
1)If successfully:
OK

+CMQTTCONNECT: <client_index>,0
Write Command
2)If failed:
AT+CMQTTCONNECT=<clien
OK
t_index>,<server_addr>,<kee
palive_time>,<clean_session
+CMQTTCONNECT: <client_index>,<err>
>[,<user_name>[,<pass_word
3)If failed:
>]]
+CMQTTCONNECT: <client_index>,<err>

ERROR
4)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

A numeric parameter that identifies a client. The range of permitted


<client_index>
values is 0 to 1.
The string that described the server address and port. The range of
the string length is 9 to 256 bytes. The string should be like this
<server_addr>
"tcp://116.247.119.165:5141", must begin with "tcp://". If the
<server_addr> not include the port, the default port is 1883.
The time interval between two messages received from a client. The
client will send a keep-alive packet when there is no message sent to
<keepalive_time>
server after song long time. The range is from 1s to 64800s (18
hours).
The clean session flag. The value range is from 0 to 1, and default
value is 0.
0 the server must store the subscriptions of the client after it
disconnected. This includes continuing to store QoS 1 and
<clean_session> QoS 2 messages for the subscribed topics so that they can be
delivered when the client reconnects. The server must also
maintain the state of in-flight messages being delivered at the
point the connection is lost. This information must be kept until
the client reconnects.

www.simcom.com 362 / 483


A76XX Series_AT Command Manual_V1.04

1 the server must discard any previously maintained information


about the client and treat the connection as "clean". The server
must also discard any state when the client disconnects.
The user name identifies the name of the user which can be used for
<user_name> authentication when connecting to server. The string length is from 1
to 256 bytes.
The password corresponding to the user which can be used for
<pass_word> authentication when connecting to server. The string length is from 1
to 256 bytes.
The result code: 0 is success. Other values are failure. Please refer to
<err>
chapter 18.3.

Examples

AT+CMQTTCONNECT=0,"tcp://120.27.2.154:1883",20,1
OK

+CMQTTCONNECT: 0,0
AT+CMQTTCONNECT?
+CMQTTCONNECT: 0,"tcp://120.27.2.154:1883",20,1
+CMQTTCONNECT: 1

OK

NOTE

AT+CMQTTCONNECT is used to connect to a MQTT server.


If you don’t set the SSL context by AT+CMQTTSSLCFG before connecting a SSL/TLS MQTT server by
AT+CMQTTCONNECT, it will use the <client_index> (the 1st parameter of
AT+CMQTTCONNNECT)SSL context when connecting to the server.

AT+CMQTTDISC Disconnect from server

AT+CMQTTDISC is used to disconnect from the server.

AT+CMQTTDISC Disconnect from server


Response:
Test Command
+CMQTTDISC: (0-1),(0, 60-180)
AT+CMQTTDISC=?

www.simcom.com 363 / 483


A76XX Series_AT Command Manual_V1.04

OK
Response:
+CMQTTDISC: 0,<disc_state>
Read Command
+CMQTTDISC: 1,<disc_state>
AT+CMQTTDISC?

OK
Response
1)If disconnect successfully:
+CMQTTDISC: <client_index>,0

OK
2)If disconnect successfully:
OK

Write Command +CMQTTDISC: <client_index>,0


AT+CMQTTDISC=<client_in 3)If failed:
dex>,<timeout> OK

+CMQTTDISC: <client_index>,<err>
4)If failed:
ERROR
5)If failed:
+CMQTTDISC: <client_index>,<err>

ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<client_index> A numeric parameter that identifies a client. The range of permitted


values is 0 to 1.
<timeout> The timeout value for disconnection. The unit is second. The range is
60s to 180s. The default value is 0s (not set the timeout value).
<disc_state> 1 disconnection
0 connection
<err> The result code: 0 is success. Other values are failure. Please refer to
chapter 18.3.

Examples

AT+CMQTTDISC=0,120

www.simcom.com 364 / 483


A76XX Series_AT Command Manual_V1.04

OK

+CMQTTDISC: 0,0

AT+CMQTTTOPIC Input the topic of publish message

AT+CMQTTTOPIC is used to input the topic of a publish message.

AT+CMQTTTOPIC Input the topic of publish message


Response
Test Command +CMQTTTOPIC: (0-1),(1-1024)
AT+CMQTTTOPIC=?
OK
Response
1)If successfully:
>
<input data here>
Write Command OK
AT+CMQTTTOPIC=<client_i 2)If failed:
ndex>,<req_length> +CMQTTTOPIC: <client_index>,<err>

ERROR
3)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<client_index> A numeric parameter that identifies a client. The range of permitted


values is 0 to 1.
<req_length> The length of input topic data. The publish message topic should be
UTF-encoded string. The range is from 1 to 1024 bytes.
<err> The result code: 0 is success. Other values are failure. Please refer to
chapter 18.3.

Examples

AT+CMQTTTOPIC=0,9

www.simcom.com 365 / 483


A76XX Series_AT Command Manual_V1.04

>

OK

NOTE

The topic will be clean after execute AT+CMQTTPUB.

AT+CMQTTPAYLOAD Input the publish message

AT+CMQTTPAYLOAD is used to input the message body of a publish message.

AT+CMQTTPAYLOAD Input the publish message


Response
Test Command +CMQTTPAYLOAD: (0-1),(1-10240)
AT+CMQTTPAYLOAD=?
OK
Response
1)If successfully:
>
<input data here>
Write Command OK
AT+CMQTTPAYLOAD=<clien 2)If failed:
t_index>,<req_length> +CMQTTPAYLOAD: <client_index>,<err>

ERROR
3)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<client_index> A numeric parameter that identifies a client. The range of permitted


values is 0 to 1.
<req_length> The length of input message data. The publish message should be
UTF-encoded string. The range is from 1 to 10240 bytes.
<err> The result code: 0 is success. Other values are failure. Please refer to
www.simcom.com 366 / 483
A76XX Series_AT Command Manual_V1.04

chapter 18.3.

Examples

AT+CMQTTPAYLOAD=0,6
>

OK

NOTE

The topic will be clean after execute AT+CMQTTPUB.

AT+CMQTTPUB Publish a message to server

AT+CMQTTPUB is used to publish a message to MQTT server.

AT+CMQTTPUB Publish a message to server


Response
Test Command +CMQTTPUB: (0-1),(0-2),(60-180),(0-1),(0-1)
AT+CMQTTPUB=?
OK
Response
1)If successfully:
OK

+CMQTTPUB: <client_index>,0
2)If failed:
Write Command
OK
AT+CMQTTPUB=<client_ind
ex>,<qos>,<pub_timeout>[,<
+CMQTTPUB: <client_index>,<err>
ratained>[,<dup>]]
3)If failed:
+CMQTTPUB: <client_index>,<err>

ERROR
4)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
www.simcom.com 367 / 483
A76XX Series_AT Command Manual_V1.04

Reference

Defined Values

<client_index> A numeric parameter that identifies a client. The range of permitted


values is 0 to 1.
<qos> The publish message’s qos. The range is from 0 to 2.
0 at most once
1 at least once
2 exactly once
<pub_timeout> The publishing timeout interval value. Since the client publish a
message to server, it will report failed if the client receive no response
from server after the timeout value seconds. The range is from 60s to
180s.
<ratained> The retain flag of the publish message. The value is 0 or 1. The default
value is 0.
When a client sends a PUBLISH to a server, if the retain flag is set to
1, the server should hold on to the message after it has been delivered
to the current subscribers.
<dup> The dup flag to the message. The value is 0 or 1. The default value is
0. The flag is set when the client or server attempts to re-deliver a
message.
<err> The result code: 0 is success. Other values are failure. Please refer to
chapter 18.3.

Examples

AT+CMQTTPUB=0,1,60
OK

+CMQTTPUB: 0,0

NOTE

The topic and payload will be clean after execute AT+CMQTTPUB.

AT+CMQTTSUBTOPIC Input the topic of subscribe message

www.simcom.com 368 / 483


A76XX Series_AT Command Manual_V1.04

AT+CMQTTSUBTOPIC is used to input the topic of a subscribe message.

AT+CMQTTSUBTOPIC Input the topic of subscribe message


Response
Test Command +CMQTTSUBTOPIC: (0-1),(1-1024),(0-2)
AT+CMQTTSUBTOPIC=?
OK
Response
1)If successfully:
>
<input data here>
Write Command
OK
AT+CMQTTSUBTOPIC=<clie
2)If failed:
nt_index>,<req_length>,<qo
+CMQTTSUBTOPIC: <client_index>,<err>
s>

ERROR
3)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<client_index> A numeric parameter that identifies a client. The range of permitted


values is 0 to 1.
<req_length> The length of input topic data. The publish message topic should be
UTF-encoded string. The range is from 1 to 1024 bytes.
<qos> The publish message’s qos. The range is from 0 to 2.
0 at most once
1 at least once
2 exactly once
<err> The result code: 0 is success. Other values are failure. Please refer to
chapter 18.3.

Examples

AT+CMQTTSUBTOPIC=0,9,1
>

OK

NOTE
www.simcom.com 369 / 483
A76XX Series_AT Command Manual_V1.04

The topic will be clean after execute AT+CMQTTSUB.

AT+CMQTTSUB Subscribe a message to server

AT+CMQTTSUB is used to subscribe a message to MQTT server.

AT+CMQTTSUB Subscribe a message to server


Response
Test Command +CMQTTSUB: (0-1),(1-1024),(0-2),(0-1)
AT+CMQTTSUB=?
OK
Response
1)If successfully:
OK

+CMQTTSUB: <client_index>,0
Write Command
2)If failed:
/* subscribe one or more topics
OK
which input by
AT+CMQTTSUBTOPIC*/
+CMQTTSUB: <client_index>,<err>
AT+CMQTTSUB=<client_ind
3)If failed:
ex>[,<dup>]
+CMQTTSUB: <client_index>,<err>

ERROR
4)If failed:
ERROR
Response
1)If successfully:
>
<input data here>
Write Command OK
/* subcribe one topic*/
AT+CMQTTSUB=<client_ind +CMQTTSUB: <client_index>,0
ex>,<reqLength>,<qos>[,<d 2)If failed:
up>] OK

+CMQTTSUB: <client_index>,<err>
3)If failed:
+CMQTTSUB: <client_index>,<err>

www.simcom.com 370 / 483


A76XX Series_AT Command Manual_V1.04

ERROR
4)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<client_index> A numeric parameter that identifies a client. The range of permitted


values is 0 to 1.
<req_length> The length of input topic data. The message topic should be
UTF-encoded string. The range is from 1 to 1024 bytes.
<qos> The publish message’s qos. The range is from 0 to 2.
0 at most once
1 at least once
2 exactly once
<dup> The dup flag to the message. The value is 0 or 1. The default value is
0. The flag is set when the client or server attempts to re-deliver a
message.
<err> The result code: 0 is success. Other values are failure. Please refer to
chapter 18.3.

Examples

AT+CMQTTSUB=0,9,1
>

OK

+CMQTTSUB: 0,0
AT+CMQTTSUB=0,1
OK

+CMQTTSUB: 0,0

NOTE

The topic will be clean after execute AT+CMQTTSUB.

www.simcom.com 371 / 483


A76XX Series_AT Command Manual_V1.04

AT+CMQTTUNSUBTOPIC Input the topic of unsubscribe message

AT+CMQTTUNSUBTOPIC is used to input the topic of a unsubscribe message.

AT+CMQTTUNSUBTOPIC Input the topic of unsubscribe message


Response
Test Command +CMQTTUNSUBTOPIC: (0-1),(1-1024)
AT+CMQTTUNSUBTOPIC=?
OK
Response
1)If successfully:
>
<input data here>
Write Command OK
AT+CMQTTUNSUBTOPIC=< 2)If failed:
client_index>,<req_length> +CMQTTUNSUBTOPIC: <client_index>,<err>

ERROR
3)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<client_index> A numeric parameter that identifies a client. The range of permitted


values is 0 to 1.
<req_length> The length of input topic data. The publish message topic should be
UTF-encoded string. The range is from 1 to 1024 bytes.
<err> The result code: 0 is success. Other values are failure. Please refer to
chapter 18.3.

Examples

AT+CMQTTUNSUBTOPIC=0,9
>

OK

www.simcom.com 372 / 483


A76XX Series_AT Command Manual_V1.04

NOTE

The topic will be clean after execute AT+CMQTTUNSUB.

AT+CMQTTUNSUB Unsubscribe a message to server

AT+CMQTTUNSUB is used to unsubscribe a message to MQTT server.

AT+CMQTTUNSUB Unsubscribe a message to server


Response
Test Command +CMQTTUNSUB: (0-1),(1-1024),(0-1)
AT+CMQTTUNSUB=?
OK
Response
1)If successfully:
OK

+CMQTTUNSUB: <client_index>,0
Write Command
2)If failed:
/*unsubscribe one or more
OK
topics which input by
AT+CMQTTUNSUBTOPIC*/
+CMQTTUNSUB: <client_index>,<err>
AT+CMQTTUNSUB=<client_i
3)If failed:
ndex>,<dup>
+CMQTTUNSUB: <client_index>,<err>

ERROR
4)If failed:
ERROR
Response
1)If successfully:
>
<input data here>
Write Command OK
/* unsubscribe one topic*/
AT+CMQTTUNSUB=<client_i +CMQTTUNSUB: <client_index>,0
ndex>,<reqLength>,<dup> 2)If failed:
OK

+CMQTTUNSUB: <client_index>,<err>
3)If failed:

www.simcom.com 373 / 483


A76XX Series_AT Command Manual_V1.04

+CMQTTUNSUB: <client_index>,<err>

ERROR
4)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<client_index> A numeric parameter that identifies a client. The range of permitted


values is 0 to 1.
<req_length> The length of input topic data. The message topic should be
UTF-encoded string. The range is from 1 to 1024 bytes.
<dup> The dup flag to the message. The value is 0 or 1. The default value is
0. The flag is set when the client or server attempts to re-deliver a
message.
<err> The result code: 0 is success. Other values are failure. Please refer to
chapter 18.3.

Examples

AT+CMQTTUNSUBTOPIC=0,9
>

OK

+CMQTTUNSUB: 0,0
AT+CMQTTUNSUB=0,1
OK

+CMQTTUNSUB: 0,0

NOTE

The topic will be clean after execute AT+CMQTTUNSUB.

www.simcom.com 374 / 483


A76XX Series_AT Command Manual_V1.04

AT+CMQTTCFG Configure the MQTT Context

AT+CMQTTCFG is used to configure the MQTT context. It must be called before AT+CMQTTCONNECT
and after AT+CMQTTACCQ. The setting will be cleared after AT+CMQTTREL.

AT+CMQTTCFG Configure the MQTT Context


Response
+CMQTTCFG: "checkUTF8",(0-1),(0-1)
+CMQTTCFG: "optimeout ",(0-1),(20-120)
Test Command +CMQTTCFG:
AT+CMQTTCFG=? "aliauth",(0-1),"productkey","devicename","devicesecret"
+CMQTTCFG: "version",(0-1),(3-4)

OK
Response
+CMQTTCFG: 0,<checkUTF8_flag>,<optimeout_val>
Read Command
+CMQTTCFG: 1,<checkUTF8_flag>,<optimeout_val>
AT+CMQTTCFG?

OK
Write Command Response
/*Configure the check UTF8 1)If successfully:
flag of the specified MQTT OK
client context*/ 2)If failed:
AT+CMQTTCFG="checkUTF ERROR
8",<index>,<checkUTF8_flag
>
Write Command Response
/*Configure the max timeout 1)If successfully:
interval of the send or receive OK
data operation */ 2)If failed:
AT+CMQTTCFG="optimeout ERROR
",<index>,<optimeout_val>
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<checkUTF8_flag> The flag to indicate whether to check the string is UTF8 coding or not,
the default value is 1.
0 Not check UTF8 coding.
1 Check UTF8 coding.
<optimeout_val> The max timeout interval of sending or receiving data operation. The

www.simcom.com 375 / 483


A76XX Series_AT Command Manual_V1.04

range is from 20 seconds to 120 seconds, the default value is 120


seconds.

Examples

AT+CMQTTCFG?
+CMQTTCFG: 0,1,120
+CMQTTCFG: 1,1,120

OK
AT+CMQTTCFG="optimeout",0,24
OK
AT+CMQTTCFG="checkUTF8",0,0
OK
AT+CMQTTCFG?
+CMQTTCFG: 0,0,24
+CMQTTCFG: 1,1,120

OK

NOTE

The setting will be cleared after AT+CMQTTREL.

Command Result Codes

Description of <err>

<err> Description
0 operation succeeded
1 failed
2 bad UTF-8 string
3 sock connect fail
4 sock create fail
5 sock close fail

www.simcom.com 376 / 483


A76XX Series_AT Command Manual_V1.04

6 message receive fail


7 network open fail
8 network close fail
9 network not opened
10 client index error
11 no connection
12 invalid parameter
13 not supported operation
14 client is busy
15 require connection fail
16 sock sending fail
17 timeout
18 topic is empty
19 client is used
20 client not acquired
21 client not released
22 length out of range
23 network is opened
24 packet fail
25 DNS error
26 socket is closed by server
27 connection refused: unaccepted protocol version
28 connection refused: identifier rejected
29 connection refused: server unavailable
30 connection refused: bad user name or password
31 connection refused: not authorized
32 handshake fail
33 not set certificate
34 Open session failed
35 Disconnect from server failed

Unsolicited Result Codes

URC Description
When client disconnect passively,
URC "+CMQTTCONNLOST" will be
+CMQTTCONNLOST: <client_index>,<cause>
reported, then user need to connect
MQTT server again.

www.simcom.com 377 / 483


A76XX Series_AT Command Manual_V1.04

If a client subscribes to one or more


topics, any message published to
those topics are sent by the server
to the client. The following URC is
used for transmitting the message
published from server to client.
1)+CMQTTRXSTART:
<client_index>,<topic_total_len>,<p
ayload_total_len>
At the beginning of receiving
published message, the module will
report this to user, and indicate
client index with <client_index>, the
topic total length with
<topic_total_len> and the payload
total length with
+CMQTTRXSTART: <payload_total_len>.
<client_index>,<topic_total_len>,<payload_total_len> 2)+CMQTTRXTOPIC:
+CMQTTRXTOPIC: <client_index>,<sub_topic_len> <client_index>,<sub_topic_len>\r\n
<sub_topic> <sub_topic>
/*for long topic, split to multiple packets to report*/ After the command
[<CR><LF>+CMQTTRXTOPIC: "+CMQTTRXSTART" received, the
<client_index>,<sub_topic_len> module will report the second
<sub_topic>] message to user, and indicate client
+CMQTTRXPAYLOAD: <client_index>,<sub_payload_len> index with <client_index>, the topic
<sub_payload> packet length with <sub_topic_len>
/*for long payload, split to multiple packets to report*/ and the topic content with
[+CMQTTRXPAYLOAD: <client_index>,<sub_payload_len> <sub_topic> after "\r\n".
<sub_payload>] For long topic, it will be split to
+CMQTTRXEND: <client_index> multiple packets to report and the
command "+CMQTTRXTOPIC" will
be send more than once with the
rest of topic content. The sum of
<sub_topic_len> is equal to
<topic_total_len>.
3)+CMQTTRXPAYLOAD:
<client_index>,<sub_payload_len>\
r\n<sub_payload>
After the command
"+CMQTTRXTOPIC" received, the
module will send third message to
user, and indicate client index with
<client_index>, the payload packet
length with <sub_payload_len> and
the payload content with
<sub_payload> after "\r\n".
www.simcom.com 378 / 483
A76XX Series_AT Command Manual_V1.04

For long payload, the same as


"+CMQTTRXTOPIC".
4)+CMQTTRXEND: <client_index>
At last, the module will send fourth
message to user and indicate the
topic and payload have been
transmitted completely.

Defined Values

<client_index> A numeric parameter that identifies a client. The range of permitted


values is 0 to 1.
<cause> The cause of disconnection.
1 Socket is closed passively.
2 Socket is reset.
3 Network is closed.
<topic_total_len> The length of message topic received from MQTT server. The range is
from 1 to 1024 bytes.
<payload_total_len> The length of message body received from MQTT server. The range is
from 1 to 10240 bytes.
<sub_topic_len> The sub topic packet length, The sum of <sub_topic_len> is equal to
<topic_total_len>.
<sub_topic> The sub topic content.
<sub_payload_len> The sub message body packet length, The sum of <sub_payload_len>
is equal to <payload_total_len>.
<sub_payload> The sub message body content.

www.simcom.com 379 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for SSL


Overview of AT Commands for SSL

Command Description
AT+CSSLCFG Configure the SSL Context
AT+CCERTDOWN Download certificate into the module
AT+CCERTLIST List certificates
AT+CCERTDELE Delete certificates
AT+CCHSET Configure the report mode of sending and receiving data
AT+CCHMODE Configure the mode of sending and receiving data
AT+CCHSTART Start SSL service
AT+CCHSTOP Stop SSL service
AT+CCHADDR Get the IPv4 address
AT+CCHSSLCFG Set the SSL context
AT+CCHCFG Configure the Client Context
AT+CCHOPEN Connect to server
AT+CCHCLOSE Disconnect from server
AT+CCHSEND Send data to server
AT+CCHRECV Read the cached data that received from the server

Detailed Description of AT Commands for SSL

AT+CSSLCFG Configure the SSL Context

AT+CSSLCFG Configure the SSL Context


Response
+CSSLCFG: "sslversion",(0-9),(0-4)
Test Command
+CSSLCFG: "authmode",(0-9),(0-3)
AT+CSSLCFG=?
+CSSLCFG: "ignorelocaltime",(0-9),(0,1)
+CSSLCFG: "negotiatetime",(0-9),(10-300)

www.simcom.com 380 / 483


A76XX Series_AT Command Manual_V1.04

+CSSLCFG: "cacert",(0-9),(5-108)
+CSSLCFG: "clientcert",(0-9),(5-108)
+CSSLCFG: "clientkey",(0-9),(5-108)
+CSSLCFG: "enableSNI",(0-9),(0,1)

OK
Response
+CSSLCFG:
0,<sslversion>,<authmode>,<ignoreltime>,<negotiatetime>,<ca
_file>,<clientcert_file>,<clientkey_file>,<enableSNI>
+CSSLCFG:
1,<sslversion>,<authmode>,<ignoreltime>,<negotiatetime>,<ca
_file>,<clientcert_file>,<clientkey_file>,<enableSNI>
+CSSLCFG:
2,<sslversion>,<authmode>,<ignoreltime>,<negotiatetime>,<ca
_file>,<clientcert_file>,<clientkey_file>,<enableSNI>
+CSSLCFG:
3,<sslversion>,<authmode>,<ignoreltime>,<negotiatetime>,<ca
_file>,<clientcert_file>,<clientkey_file>,<enableSNI>
+CSSLCFG:
4,<sslversion>,<authmode>,<ignoreltime>,<negotiatetime>,<ca
_file>,<clientcert_file>,<clientkey_file>,<enableSNI>
Read Command
+CSSLCFG:
AT+CSSLCFG?
5,<sslversion>,<authmode>,<ignoreltime>,<negotiatetime>,<ca
_file>,<clientcert_file>,<clientkey_file>,<enableSNI>
+CSSLCFG:
6,<sslversion>,<authmode>,<ignoreltime>,<negotiatetime>,<ca
_file>,<clientcert_file>,<clientkey_file>,<enableSNI>
+CSSLCFG:
7,<sslversion>,<authmode>,<ignoreltime>,<negotiatetime>,<ca
_file>,<clientcert_file>,<clientkey_file>,<enableSNI>
+CSSLCFG:
8,<sslversion>,<authmode>,<ignoreltime>,<negotiatetime>,<ca
_file>,<clientcert_file>,<clientkey_file>,<enableSNI>
+CSSLCFG:
9,<sslversion>,<authmode>,<ignoreltime>,<negotiatetime>,<ca
_file>,<clientcert_file>,<clientkey_file>,<enableSNI>

OK
Response
Write Command
+CSSLCFG:
/*Query the configuration of the
<ssl_ctxindex>,<sslversion>,<authmode>,<ignoreltime>,<nego
specified SSL context*/
tiatetime>,<ca_file>,<clientcert_file>,<clientkey_file>,<enableS
AT+CSSLCFG=<ssl_ctx_inde
NI>
x>

www.simcom.com 381 / 483


A76XX Series_AT Command Manual_V1.04

OK
Write Command Response
/*Configure the version of the 1)If successfully:
specified SSL context*/ OK
AT+CSSLCFG="sslversion",< 2)If failed:
ssl_ctx_index>,<sslversion> ERROR
Write Command Response
/*Configure the authentication 1)If successfully:
mode of the specified SSL OK
context*/ 2)If failed:
AT+CSSLCFG="authmode",< ERROR
ssl_ctx_index>,<authmode>
Write Command Response
/*Configure the ignore local time 1)If successfully:
flag of the specified SSL OK
context*/ 2)If failed:
AT+CSSLCFG="ignorelocalti ERROR
me",<ssl_ctx_index>,<ignorel
time>
Write Command Response
/*Configure the negotiate 1)If successfully:
timeout value of the specified OK
SSL context*/ 2)If failed:
AT+CSSLCFG="negotiatetime ERROR
",<ssl_ctx_index>,<negotiatet
ime>
Write Command Response
/*Configure the server root CA of 1)If successfully:
the specified SSL context*/ OK
AT+CSSLCFG="cacert",<ssl_ 2)If failed:
ctx_index>,<ca_file> ERROR
Write Command Response
/*Configure the client certificate 1)If successfully:
of the specified SSL context*/ OK
AT+CSSLCFG="clientcert",<s 2)If failed:
sl_ctx_index>,<clientcert_file ERROR
>
Write Command Response
/*Configure the client key of the 1)If successfully:
specified SSL context*/ OK
AT+CSSLCFG="clientkey",<s 2)If failed:
sl_ctx_index>,<clientkey_file> ERROR
Write Command Response
/*Configure the enableSNI flag 1)If successfully:
of the specified SSL context */ OK

www.simcom.com 382 / 483


A76XX Series_AT Command Manual_V1.04

AT+CSSLCFG="enableSNI",< 2)If failed:


ssl_ctx_index>,<enableSNI_fl ERROR
ag>
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<ssl_ctx_index> The SSL context ID. The range is 0-9.


<sslversion> The SSL version, the default value is 4.
0 SSL3.0
1 TLS1.0
2 TLS1.1
3 TLS1.2
4 All

The configured version should be support by server. So you should


use the default value if you are not sure that the version which the
server supported.
<authmode> The authentication mode, the default value is 0.
0 no authentication.
1 server authentication. It needs the root CA of the server.
2 server and client authentication. It needs the root CA of the
server, the cert and key of the client.
3 client authentication and no server authentication. It needs the
cert and key of the client.
<ignoreltime> The flag to indicate how to deal with expired certificate, the default
value is 1.
0 care about time check for certification.
1 ignore time check for certification
When set the value to 0, it need to set the right current date and time
by AT+CCLK when need SSL certification.
<negotiatetime> The timeout value used in SSL negotiate stage. The range is 10-300
seconds. The default value is 300.
<ca_file> The root CA file name of SSL context. The file name must have type
like ".pem" or ".der". The length of filename is from 5 to 108 bytes.
If the filename contains non-ASCII characters, the file path
parameter should contain a prefix of {non-ascii} and the quotation
mark (The string in the quotation mark should be hexadecimal of the
filename’s UTF8 code).

There are two ways to download certificate files to module:


1. By AT+CCERTDOWN.

www.simcom.com 383 / 483


A76XX Series_AT Command Manual_V1.04

2. By FTPS or HTTPS commands. Please refer to Chapter 16&17 of


this document.
<clientcert_file> The client cert file name of SSL context. The file name must have
type like ".pem" or ".der". The length of filename is from 5 to 108
bytes.
If the filename contains non-ASCII characters, the file path
parameter should contain a prefix of {non-ascii} and the quotation
mark (The string in the quotation mark should be hexadecimal of the
filename’s UTF8 code).

There are two ways to download certificate files to module:


1. By AT+CCERTDOWN.
2. By FTPS or HTTPS commands. Please refer to Chapter 16&17 of
this document.
<clientkey_file> The client key file name of SSL context. The file name must have
type like ".pem" or ".der". The length of filename is from 5 to 108
bytes.
If the filename contains non-ASCII characters, the file path
parameter should contain a prefix of {non-ascii} and the quotation
mark (The string in the quotation mark should be hexadecimal of the
filename’s UTF8 code).

There are two ways to download certificate files to module:


1. By AT+CCERTDOWN.
2. By FTPS or HTTPS commands. Please refer to Chapter 16&17 of
this document.
<enalbeSNI_flag> The flag to indicate that enable the SNI flag or not, the default value
is 0.
0 not enable SNI.
1 enable SNI.

Examples

AT+CSSLCFG=?
+CSSLCFG: "sslversion",(0-9),(0-4)
+CSSLCFG: "authmode",(0-9),(0-3)
+CSSLCFG: "ignorelocaltime",(0-9),(0,1)
+CSSLCFG: "negotiatetime",(0-9),(10-300)
+CSSLCFG: "cacert",(0-9),(5-108)
+CSSLCFG: "clientcert",(0-9),(5-108)
+CSSLCFG: "clientkey",(0-9),(5-108)
+CSSLCFG: "enableSNI",(0-9),(0,1)

OK

www.simcom.com 384 / 483


A76XX Series_AT Command Manual_V1.04

AT+CSSLCFG?
+CSSLCFG: 0,4,0,1,300,"","","",0
+CSSLCFG: 1,4,0,1,300,"","","",0
+CSSLCFG: 2,4,0,1,300,"","","",0
+CSSLCFG: 3,4,0,1,300,"","","",0
+CSSLCFG: 4,4,0,1,300,"","","",0
+CSSLCFG: 5,4,0,1,300,"","","",0
+CSSLCFG: 6,4,0,1,300,"","","",0
+CSSLCFG: 7,4,0,1,300,"","","",0
+CSSLCFG: 8,4,0,1,300,"","","",0
+CSSLCFG: 9,4,0,1,300,"","","",0

OK
AT+CSSLCFG="authmode",0,0
OK
AT+CSSLCFG=6
+CSSLCFG: 6,4,0,1,300,"","","",0

OK

AT+CCERTDOWN Download certificate into the module

AT+CCERTDOWN Download certificate into the module


Response
Test Command +CCERTDOWN: (5-108),(1-10240)
AT+CCERTDOWN=?
OK
Response
1)If it can be download:
>
Write Command
<input data here>
AT+CCERTDOWN=<filename>,<
len>
OK
2)If failed:
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

www.simcom.com 385 / 483


A76XX Series_AT Command Manual_V1.04

<filename> The name of the certificate/key file. The file name must have type like
".pem" or ".der". The length of filename is from 5 to 108 bytes.
If the filename contains non-ASCII characters, the file path parameter
should contain a prefix of {non-ascii} and the quotation mark (The
string in the quotation mark should be hexadecimal of the filename’s
UTF8 code).
For Examples: If you want to download a file with name "中华.pem",
you should convert the "中华.pem" to UTF8 coding
(&#x4E2D;&#x534E;.pem), then input the hexadecimal
(262378344532443B262378353334453B2E70656D)of UTF8 coding.
<len> The length of the file data to send. The range is from 1 to 10240 bytes.
User should note than every packet data should be no larger than
3072 bytes.

Examples

AT+CCERTDOWN=?
+CCERTDOWN: (5-108),(1-10240)

OK
AT+CCERTDOWN="ls.pem",1970
>

OK

AT+CCERTLIST List certificates

AT+CCERTLIST List certificates


Response
[+CCERTLIST: <file_name>
[+CCERTLIST: <file_name>]
Execute Command

AT+CCERTLIST
]

OK
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values
www.simcom.com 386 / 483
A76XX Series_AT Command Manual_V1.04

<filename> The certificate/key files which has been downloaded to the module.
If the filename contains non-ASCII characters, it will show the
non-ASCII characters as UTF8 code.

Examples

AT+CCERTLIST
+CCERTLIST: "ls.pem"

OK

AT+CCERTDELE Delete certificates

AT+CCERTDELE Delete certificates


Response
1) If remove the file successfully:
Write Command
OK
AT+CCERTDELE=<filename>
2) Else
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<filename> The name of the certificate/key file. The file name must have type
like ".pem" or ".der". The length of filename is from 5 to 108 bytes.
If the filename contains non-ASCII characters, the file path
parameter should contain a prefix of {non-ascii} and the quotation
mark (The string in the quotation mark should be hexadecimal of the
filename’s UTF8 code).
For Examples: If you want to download a file with name "中华.pem",
you should convert the "中华.pem" to UTF8 coding
(&#x4E2D;&#x534E;.pem), then input the hexadecimal
(262378344532443B262378353334453B2E70656D)of UTF8
coding.

Examples
www.simcom.com 387 / 483
A76XX Series_AT Command Manual_V1.04

AT+CCERTDELE="ls.pem"
OK

AT+CCHSET Configure the report mode of sending and receiving data

AT+CCHSET is used to configure the mode of sending and receiving data. It must be called before
AT+CCHSTART.

AT+CCHSET Configure the report mode of sending and receiving data


Response
Test Command +CCHSET: (0,1),(0,1)
AT+CCHSET=?
OK
Response
Read Command +CCHSET: <report_send_result>,<recv_mode>
AT+CCHSET?
OK
Response
Write Command 1)If successfully:
AT+CCHSET=<report_send_res OK
ult>[,<recv_mode>] 2)If failed:
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<report_send_result> Whether to report result of CCHSEND, the default value is 0:


0 No.
1 Yes. Module will report +CCHSEND: <session_id>,<err> to MCU
when complete sending data.
<recv_mode> The receiving mode, the default value is 0:
0 Output the data to MCU whenever received data.
1 Module caches the received data and notifies MCU with
+CCHEVENT: <session_id>, RECV EVENT.
MCU can use AT+CCHRECV to receive the cached data (only in
manual receiving mode).

www.simcom.com 388 / 483


A76XX Series_AT Command Manual_V1.04

Examples

AT+CCHSET=?
+CCHSET: (0,1),(0,1)

OK
AT+CCHSET?
+CCHSET: 0,0

OK
AT+CCHSET=1,1
OK

AT+CCHMODE Configure the mode of sending and receiving data

AT+CCHMODE is used to select transparent mode (data mode)or non-transparent mode (command mode).
The default mode is non-transparent mode. This AT command must be called before calling
AT+CCHSTART.

AT+CCHMODE Configure the mode of sending and receiving data


Response
Test Command +CCHMODE: (0,1)
AT+CCHMODE=?
OK
Response
Read Command +CCHMODE: <mode>
AT+CCHMODE?
OK
Response
1)If successfully:
Write Command
OK
AT+CCHMODE=<mode>
2)If failed:
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<mode> The mode value:


0 Normal
www.simcom.com 389 / 483
A76XX Series_AT Command Manual_V1.04

1 Transparent mode

Examples

AT+CCHMODE=?
+CCHMODE: (0,1)

OK
AT+CCHMODE?
+CCHMODE: 0

OK
AT+CCHMODE=1
OK

NOTE

There is only one session in the transparent mode, it’s the first session.

AT+CCHSTART Start SSL service

AT+CCHSTART is used to start SSL service by activating PDP context. You must execute AT+CCHSTART
before any other SSL related operations.

AT+CCHSTART Start SSL service


Response
1)If start SSL service successfully:
OK

+CCHSTART: 0
Execute Command
2)If failed:
AT+CCHSTART
ERROR
3)If failed:
ERROR

+CCHSTART: <err>
Parameter Saving Mode -
Max Response Time 120000ms

www.simcom.com 390 / 483


A76XX Series_AT Command Manual_V1.04

Reference -

Defined Values

<err> The result code, please refer to the end of this chapter

Examples

AT+CCHSTART
OK

+CCHSTART: 0

AT+CCHSTOP Stop SSL service

AT+CCHSTOP is used to stop SSL service.

AT+CCHSTOP Stop SSL service


Response
1)If stop SSL service successfully:
OK
Execute Command
AT+CCHSTOP
+CCHSTOP: 0
2)If failed:
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<err> The result code, please refer to the end of this chapter

Examples

AT+CCHSTOP
OK
www.simcom.com 391 / 483
A76XX Series_AT Command Manual_V1.04

+CCHSTOP: 0

AT+CCHADDR Get the IPv4 address

AT+CCHADDR is used to get the IPv4 address after calling AT+CCHSTART.

AT+CCHADDR Get the IPv4 address


Response
1)if successfully, response
+CCHADDR: <ip_address>
Execute Command
AT+CCHADDR
OK
2)if pdp has not been activated, response
ERROR
Parameter Saving Mode -
Max Response Time 12000ms
Reference -

Defined Values

<ip address> A string parameter that identifies the IPv4 address after PDP
activated.

Examples

AT+CCHADDR
+CCHADDR: 10.43.71.130

OK

AT+CCHSSLCFG Set the SSL context

AT+CCHSSLCFG is used to set the SSL context which to be used in the SSL connection. It must be called
before AT+CCHOPEN and after AT+CCHSTART. The setting will be cleared after AT+CCHOPEN failed or
AT+CCHCLOSE.

www.simcom.com 392 / 483


A76XX Series_AT Command Manual_V1.04

AT+CCHSSLCFG Set the SSL context


Response
Test Command +CCHSSLCFG: (0,1),(0-9)
AT+CCHSSLCFG=?
OK
Response
+CCHSSLCFG: <session_id>,[<ssl_ctx_index>]
Read Command
+CCHSSLCFG: <session_id>,[<ssl_ctx_index>]
AT+CCHSSLCFG?

OK
Response
Write Command 1)If successfully:
AT+CCHSSLCFG=<session_id> OK
,<ssl_ctx_index> 2)If failed:
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<session_id> The session_id to operate. It’s from 0 to 1.


<ssl_ctx_index> The SSL context ID which will be used in the SSL
connection. Refer to the <ssl_ctx_index> of AT+CSSLCFG.

Examples

AT+CCHSSLCFG=?
+CCHSSLCFG: (0,1),(0-9)

OK
AT+CCHSSLCFG?
+CCHSSLCFG: 0,
+CCHSSLCFG: 1,

OK
AT+CCHSSLCFG=0,1
OK

NOTE

www.simcom.com 393 / 483


A76XX Series_AT Command Manual_V1.04

AT+CCHSSLCFG is used to set the SSL context which to be used in the SSL connection. It must be
called before AT+CCHOPEN and after AT+CCHSTART. The setting will be cleared after AT+CCHOPEN
failed or AT+CCHCLOSE
If you don’t set the SSL context by this command before connecting to SSL/TLS server by
AT+CCHOPEN, the CCHOPEN operation will use the SSL context as same as index <session_id> (the
1st parameter of AT+CCHOPEN)when connecting to the server.

AT+CCHCFG Configure the Client Context

AT+CCHCFG is used to set the client session context. It must be called before AT+CCHOPEN and after
AT+CCHSTART. The setting will be cleared after AT+CCHOPEN failed or AT+CCHCLOSE.

AT+CCHCFG Configure the Client Context


Response
+CCHCFG: "sendtimeout",(0-1),(60-150)
Test Command
+CCHCFG: "sslctx",(0-1),(0-9)
AT+CCHCFG=?

OK
Response
+CCHCFG: 0,<sendtimeout_val>,<sslctx_index>
Read Command
+CCHCFG: 1,<sendtimeout_val>,<sslctx_index>
AT+CCHCFG?

OK
Write Command
Response
/*Configure the timeout value of
1)If successfully:
the specified client when sending
OK
data*/
2)If failed:
AT+CCHCFG="sendtimeout",<s
ERROR
ession_id>,<sendtimeout_val>
Write Command Response
/*Configure the SSL context index, 1)If successfully:
it’s as same as OK
AT+CCHSSLCFG*/ 2)If failed:
AT+CCHCFG="sslctx",<session ERROR
_id>,<sslctx_index>
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

www.simcom.com 394 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<session_id> The session_id to operate. It’s from 0 to 1.


<sendtimeout_val> The timeout value used in sending data stage. The range is 60-150
seconds. The default value is 150.
<sslctx_index> The SSL context ID which will be used in the SSL connection. Refer to
the <ssl_ctx_index> of AT+CSSLCFG.

Examples

AT+CCHCFG=?
+CCHCFG: "sendtimeout",(0-1),(60-150)
+CCHCFG: "sslctx",(0-1),(0-9)

OK
AT+CCHCFG?
+CCHCFG: 0,150,
+CCHCFG: 1,150,

OK
AT+CCHCFG="sendtimeout",0,120
OK
AT+CCHCFG="sslctx",0,3
OK

AT+CCHOPEN Connect to server

AT+CCHOPEN is used to connect the server.

AT+CCHOPEN Connect to server


Response
Test Command +CCHOPEN: (0,1),"ADDRESS",(1-65535)[,(1-2)[,(1-65535)]]
AT+CCHOPEN=?
OK
Response
If connect to a server, it will show the connected information.
Read Command Otherwise, the connected information is empty.
AT+CCHOPEN? +CCHOPEN: 0,<host>,<port>,<client_type>,<bind_port>
+CCHOPEN: 1,<host>,<port>,<client_type>,<bind_port>

www.simcom.com 395 / 483


A76XX Series_AT Command Manual_V1.04

OK
Response
1)If connect successfully:
OK

+CCHOPEN: <session_id>,0
2)If connect successfully in transparent mode:
Write Command
CONNECT [<text>]
AT+CCHOPEN=<session_id>,<
3)If failed:
host>,<port>[,<client_type>,[<bi
OK
nd_port>]]

+CCHOPEN: <session_id>,<err>
4)If failed:
ERROR
5)If failed in transparent mode:
CONNECT FAIL
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<session_id> The session index to operate. It’s from 0 to 1.


<host> The server address, maximum length is 256 bytes.
The server port which to be connected, the range is from 1 to
<port>
65535.
The type of client, default value is 2:
<client_type> 1 TCP client.
2 SSL/TLS client.
<bind_port> The local port for channel, the range is from 1 to 65535.
CONNECT result code string; the string formats please refer ATX
<text>
command.
The result code: 0 is success. Other values are failure. Please
<err>
refer to chapter 19.3

Examples

AT+CCHOPEN=?
+CCHOPEN: (0,1),"ADDRESS",(1-65535)[,(1-2)[,(1-65535)]]

OK
AT+CCHOPEN=0,"183.230.174.137",6043,1

www.simcom.com 396 / 483


A76XX Series_AT Command Manual_V1.04

OK

+CCHOPEN: 0,0
AT+CCHOPEN?
+CCHOPEN: 0,"183.230.174.137",6043,1,
+CCHOPEN: 1,"",,,

OK

NOTE

If you don’t set the SSL context by AT+CCHSSLCFG before connecting a SSL/TLS server by
AT+CCHOPEN, it will use the <session_id>( the 1’st parameter of AT+CCHOPEN)SSL context when
connecting to the server.

AT+CCHCLOSE Disconnect from server

AT+CCHCLOSE is used to disconnect from the server.

AT+CCHCLOSE Disconnect from server


Response
1)If successfully:
OK

+CCHCLOSE: <session_id>,0
Write Command
2)If successfully in transparent mode:
AT+CCHCLOSE=<session_id>
OK

CLOSED
3)If failed:
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<session_id> The session index to operate. It’s from 0 to 1.

www.simcom.com 397 / 483


A76XX Series_AT Command Manual_V1.04

The result code: 0 is success. Other values are failure. Please


<err>
refer to the end of this chapter.

Examples

AT+CCHCLOSE=0
OK

+CCHCLOSE: 0,0

AT+CCHSEND Send data to server

AT+CCHSEND Send data to server


Response
Test Command +CCHSEND: (0,1),(1-2048)
AT+CCHSEND=?
OK
Response
Read Command +CCHSEND: 0,<unsent_len_0>,1,<unsent_len_1>
AT+CCHSEND?
OK
Response
1)if parameter is right:
>
<input data here>
Write Command
When the total size of the inputted data reaches <len>, TA will
AT+CCHSEND=<session_id>,<l
report the following code. Otherwise, the serial port will be
en>
blocked.
OK
2)If parameter is wrong or other errors occur:
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<session_id> The session_id to operate. It’s from 0 to 1.


<len> The length of data to send. Its range is from 1 to 2048 bytes.
<unsent_len_0> The data of connection 0 cached in sending buffer which is waiting
www.simcom.com 398 / 483
A76XX Series_AT Command Manual_V1.04

to be sent.
<unsent_len_1> The data of connection 1 cached in sending buffer which is waiting
to be sent.

Examples

AT+CCHSEND=?
+CCHSEND: (0,1),(1-2048)

OK
AT+CCHSEND?
+CCHSEND: 0,0,1,0

OK
AT+CCHSEND=0,121
> GET / HTTP/1.1
Host: www.baidu.com
User-Agent: MAUI htp User Agent
Proxy-Connection: keep-alive
Content-Length: 0

OK

AT+CCHRECV Read the cached data that received from the server

AT+CCHRECV Read the cached data that received from the server
Response
Read Command +CCHRECV: LEN,<cache_len_0>,<cache_len_1>
AT+CCHRECV?
OK
Response
1)if parameter is right and there are cached data:
OK

Write Command
[+CCHRECV: DATA,<session_id>,<len>
AT+CCHRECV=<session_id>[,<

max_recv_len>]
+CCHRECV: DATA,<session_id>,<len>
…]
+CCHRECV: <session_id>,<err>

www.simcom.com 399 / 483


A76XX Series_AT Command Manual_V1.04

2)if parameter is not right or any other error occurs:


+CCHRECV: <session_id>,<err>

ERROR

3)others:
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<session_id> The session id to operate. It’s from 0 to 1.


<max_recv_len> Maximum bytes of data to receive in the current AT+CCHRECV
calling. It will read all the received data when the value is greater
than the length of RX data cached for session <session_id>.
0 means the maximum bytes to receive is 2048 bytes. (But, when
2048 is greater than the length of RX data cached for session
<session_id>, 0 means the length of RX data cached for session
<session_id>).
The default value is the length of RX data cached for session
<session_id>.
It will be not allowed when there is no data in the cache.
<cache_len_0> The length of RX data cached for connection 0.
<cache_len_1> The length of RX data cached for connection 1.
<len> The length of data followed.
<err> The result code: 0 is success. Other values are failure. Please
refer to chapter 19.3

Examples

AT+CCHRECV?
+CCHRECV: LEN,3072,0

OK
AT+CCHRECV=0
OK

+CCHRECV: DATA,0,1024
HTTP/1.1 200 OK
Bdpagetype: 1
Bdqid: 0x9821f6dd000060aa
www.simcom.com 400 / 483
A76XX Series_AT Command Manual_V1.04

Cache-Control: private
Connection: keep-alive
Content-Type: text/html;charset=utf-8
Date: Tue, 24 Mar 2020 02:27:10 GMT
Expires: Tue, 24 Mar 2020 02:26:31 GMT
P3p: CP=" OTI DSP COR IVA OUR IND COM "
P3p: CP=" OTI DSP COR IVA OUR IND COM "
Server: BWS/1.1
Set-Cookie: BAIDUID=F0CD980BA0927350B147AB1064A3423D:FG=1; expires=Thu, 31-Dec-37
23:55:55 GMT; max-age=2147483647; path=/; domain=.baidu.com
Set-Cookie: BIDUPSID=F0CD980BA0927350B147AB1064A3423D; expires=Thu, 31-Dec-37 23:55:55
GMT; max-age=2147483647; path=/; domain=.baidu.com
Set-Cookie: PSTM=1585016830; expires=Thu, 31-Dec-37 23:55:55 GMT; max-age=2147483647;
path=/; domain=.baidu.com
Set-Cookie: BAIDUID=F0CD980BA0927350739AA64356C3CB13:FG=1; max-age=31536000;
expires=Wed, 24-Mar-21 02:27:10 GMT; domain=.baidu.com; path=/; version=1; comment=bd
Set-Cookie: BDSVRTM=0; path=/
Set-Cookie: BD_HOME=1; path=/
Set-Cookie: H_PS_PSSID=30972_1467_21116_30823; path=/; domain=.baidu.com
Traceid
+CCHRECV: DATA,0,1024
: 1585016830040414772210962314397044727978
Vary: Accept-Encoding
Vary: Accept-Encoding
X-Ua-Compatible: IE=Edge,chrome=1
Transfer-Encoding: chunked

b5e
<!DOCTYPE html><!--STATUS OK--><html><head><meta http-equiv="Content-Type"
content="text/html;charset=utf-8"><meta http-equiv="X-UA-Compatible"
content="IE=edge,chrome=1"><meta content="always" name="referrer"><meta
name="theme-color" content="#2932e1"><link rel="shortcut icon" href="/favicon.ico"
type="image/x-icon" /><link rel="search" type="application/opensearchdescription+xml"
href="/content-search.xml" title="鐧惧害鎼滅储" /><link rel="icon" sizes="any" mask
href="//www.baidu.com/img/baidu_85beaf5496f291521eb75ba38eacbd87.svg"><link
rel="dns-prefetch" href="//dss0.bdstatic.com"/><link rel="dns-prefetch"
href="//dss1.bdstatic.com"/><link rel="dns-prefetch" href="//ss1.bdstatic.com"/><link
rel="dns-prefetch" href="//sp0.baidu.com"/><link rel="dns-prefetch" href="//sp1.baidu.com"/><link
rel="dns-prefetch" href="//sp2.baidu.com"/><title>鐧惧害涓€涓?
+CCHRECV: DATA,0,1024
紝浣犲氨鐭ラ亾</title><style type="text/css" id="css_index"
index="index">body,html{height:100%}html{overflow-y:auto}body{font:12px
arial;background:#fff}body,form,li,p,ul{margin:0;padding:0;list-style:none}#fm,body,form{position:
relative}td{text-align:left}img{border:0}a{text-decoration:none}a:active{color:#f60}input{border:0;p

www.simcom.com 401 / 483


A76XX Series_AT Command Manual_V1.04

adding:0}.clearfix:after{content:'\20';display:block;height:0;clear:both}.clearfix{zoom:1}#wrapper{p
osition:relative;min-height:100%}#head{padding-bottom:100px;text-align:center;*z-index:1}#ftCon{
height:50px;position:absolute;text-align:left;width:100%;margin:0
auto;z-index:0;overflow:hidden}#ftConw{display:inline-block;text-align:left;margin-left:33px;line-he
ight:22px;position:relative;top:-2px;*float:right;*margin-left:0;*position:static}#ftConw,#ftConw
a{color:#999}#ftConw{text-align:center;margin-left:0}.bg{background-image:url(http://ss.bdimg.co
m/static/superman/img/icons-5859e577e2.png);background-repeat:no-repeat;_background-image:u
rl(http://ss.bdimg.com/static/superman/img/icon
+CCHRECV: 0,0

+CCHEVENT: 0,RECV EVENT

NOTE

If connection is closed by server, the cached data will not be cleaned.

Command Result Codes

Description of <err>

Result codes Description


0 Operation succeeded
1 Alerting state(reserved)
2 Unknown error
3 Busy
4 Peer closed
5 Operation timeout
6 Transfer failed
7 Memory error
8 Invalid parameter
9 Network error
10 Open session error
11 State error
12 Create socket error
13 Get DNS error

www.simcom.com 402 / 483


A76XX Series_AT Command Manual_V1.04

14 Connect socket error


15 Handshake error
16 Close socket error
17 Nonet
18 Send data timeout
19 Not set certificates

Unsolicited Result Codes

URC Description
In manual receiving mode, when new data of a
+CCHEVENT: <session_id>,RECV EVENT connection arriving to the module, this unsolicited
result code will be reported to MCU.
When receive data occurred any error, this
+CCH_RECV_CLOSED: <session_id>,<err>
unsolicited result code will be reported to MCU.
+CCH_PEER_CLOSED: <session_id> The connection is closed by the server.

www.simcom.com 403 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for TTS


Overview of AT Commands for TTS

Command Description
AT+CTTS TTS operation
AT+CTTSPARAM Set TTS parameters
AT+CDTAM Set TTS Play Path

Detailed Description of AT Commands for TTS

AT+CTTS TTS operation

The write command is used to play/decode/pause TTS.

AT+CTTS TTS operation


Test Command Response
AT+CTTS=? OK
Response
Read Command +CTTS: <status>
AT+CTTS?
OK
Response
1)If <mode>is 0,and tts is playing:
+CTTS: 0

Write Command OK
AT+CTTS=<mode>,[<text>],[<fil 2)If <mode>is 0,and tts is not playing:
ename>] OK
3)If <mode>is 1 or 2:
+CTTS:

OK

www.simcom.com 404 / 483


A76XX Series_AT Command Manual_V1.04

+CTTS: 0 // transform end


4)If <mode>is 3 or 4:
+CTTS:

OK

+CTTS: 0 // transform end


5)
ERROR
Parameter Saving Mode -
Max Response Time 120000ms
Reference -

Defined Values

<status> 0 NO_WORKING
6 TTS_WORKING
<mode> 0 Stop the speech play
1 Start to synth and play,<text> is in UCS2 coding format.
2 Start to synth and play,<text> is in ASCII coding format,
Chinses texi is in GBK coding format.
3 TTS To wav format,<text> is in ASCII coding format, Chinese
text is in GBK coding format.
4 TTS To wav format,<text> is in UCS2 coding format.
<text> When mode is 1 or 2,the <text> is in ASCII coding format which is
synthetized to speed to be played, maximum data length is 512
bytes.(including "").And <text> is in UCS2 coding format,
maximum data length is 510 bytes. (including ""),because every
four characters correspond to one Chinese character.When mode
is 3 or 4,<text> maximum data length is 50 bytes because of the
memory.
<filename> Enter path and filename, if no path is added, save in C: by default.
Maximum filename length is 60 bytes.
Currently only .wav format file storage is supported.

NOTE

Lowercase English strings are predicted to be pronounced according to English words. If you want long
lowercase strings to be pronounced correctly, please add a space after each letter.

www.simcom.com 405 / 483


A76XX Series_AT Command Manual_V1.04

Examples

AT+CTTS=?
OK
AT+CTTS?
+CTTS: 0

OK
AT+CTTS=1,"6B228FCE4F7F75288BED97F3540862107CFB7EDF"
+CTTS:

OK

+CTTS: 0
AT+CTTS=3,"hello world","C:/12.wav"
+CTTS:

OK

+CTTS: 0

AT+CTTSPARAM Set TTS Parameters

The write command is used to Set TTS Parameters

AT+CTTSPARAM Set TTS Parameters


Response
Test Command +CTTSPARAM: (0-2),(0-3),(0-3),(0-2),(0-2),(0-1)
AT+CTTSPARAM=?
OK
Response
+CTTSPARAM:
Read Command <volume>,<sysvolume>,<digitmode>,<pitch>,<speed>,<digitr
AT+CTTSPARAM? eading>

OK
Response
Write Command
1)
AT+CTTSPARAM=<volume>[,<s
OK
ysvolume>[,<digitmode>[,<pitc
2)
h>[,<speed>[,<digitreading>]]]]
ERROR
Parameter Saving Mode Just <volume> is AUTO_SAVE

www.simcom.com 406 / 483


A76XX Series_AT Command Manual_V1.04

Max Response Time 9000ms


Reference Ventor

Defined Values

<volume> 0 The mix volume


1 The normal volume
2 The max volume
<sysvolume> 0 The mix system volume
1 The small system volume
2 The normal system volume
3 The max system volume
<digitmode> 0 Read digit based on default mode.
1 Read digit based on telephone number.
2 Read digit based on digit.
3 Read digit based on number.
<pitch> 0 The mix voice tone.
1 The normal voice tone.
2 The max voice tone.
<speed> 0 The mix speed
1 The normal speed
2 The max speed
<digitreading> 0 Read the numbers in Chinese
1 Read the numbers in English

Examples

AT+CTTSPARAM=?
+CTTSPARAM: (0-2),(0-3),(0-3),(0-2),(0-2),(0-1)

OK
AT+CTTSPARAM?
+CTTSPARAM: 1,3,0,1,1,0

OK
AT+CTTSPARAM=2,3,0,1,1,1
OK

AT+CDTAM Set Local or Remote Audio Play

www.simcom.com 407 / 483


A76XX Series_AT Command Manual_V1.04

The write command is used to Set TTS Play Path.

AT+CDTAM Set TTS Play Path


Response
Test Command +CDTAM: (0-1)
AT+CDTAM=?
OK
Response
Read Command +CDTAM: <status>
AT+CDTAM?
OK
Response
1)If <mode>is 0 or 1:
Write Command
OK
AT+CDTAM=<mode>
2)
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time -
Reference -

Defined Values

<status> 0 Local Player


1 Remote Player
<mode> 0 Local Path
1 Remote Path

Examples

AT+CDTAM=?
+CDTAM: (0-1)

OK
AT+CDTAM?
+CDTAM: 0

OK
AT+CDTAM=1
OK

www.simcom.com 408 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for Audio


Overview of AT Commands for Audio

Command Description
AT+CCMXPLAY play an audio file
AT+CCMXSTOP stop playing audio file
AT+CREC record audio file

Detailed Description of AT Commands for Audio

AT+CCMXPLAY Play audio file

This command is used to play an audio file.

AT+CCMXPLAY Play audio file


Response
+CCMXPLAY: (list of supported <play_path>s),(list of supported
Test Command
<repeat>s)
AT+CCMXPLAY=?

OK
Response
1)
+CCMXPLAY:

Write Command OK
AT+CCMXPLAY=<file_na
me>,<play_path>,<repeat> +AUDIOSTATE: audio play

+AUDIOSTATE: audio play stop


2)
ERROR
Parameter Saving Mode
www.simcom.com 409 / 483
A76XX Series_AT Command Manual_V1.04

Max Response Time


Reference

Defined Values

<file_name> The name of audio file. Support audio file format amr and wav.
<play_path> 0 local path
1 remote path (just support voice call)
<repeat> 0 don’t play repeat.play only once.
1…255 play repeat times. E.g. <repeat>=1, audio will play twice.

Examples

AT+CCMXPLAY=?
+CCMXPLAY: (0-1),(0-255)

OK
AT+CCMXPLAY="c:/recording.amr",0,255
+CCMXPLAY:

OK

+AUDIOSTATE: audio play

+AUDIOSTATE: audio play stop


AT+CCMXPLAY="c:/recording.wav",0,255
+CCMXPLAY:

OK

+AUDIOSTATE: audio play

+AUDIOSTATE: audio play stop

NOTE

support file type: AMR,WAV,MP3,PCM

www.simcom.com 410 / 483


A76XX Series_AT Command Manual_V1.04

AT+CCMXSTOP Stop playing audio file

The command is used to stop playing audio file. Execute this command during audio playing. If
audio file was played end in the past, when you execute "AT+CCMXSTOP", there is no
"+AUDIOSTATE: audio play stop".

AT+CCMXSTOP Stop playing audio file


Test Command Response
AT+CCMXSTOP=? OK
Response
1)
+CCMXSTOP:

Execution Command
OK
AT+CCMXSTOP

+AUDIOSTATE: audio play stop


2)
OK
Parameter Saving Mode
Max Response Time
Reference

Examples

AT+CCMXSTOP
+CCMXSTOP:

OK

+AUDIOSTATE: audio play stop

AT+CREC Record audio File

This command is used to record a wav/amr audio file. It can record wav/amr file during a call or not, the
record file should be put into the "c:/". The supported file format is WAV and AMR.The record path 3 only
supported on A7600 Series(1601) and A7678 Series(1603) and others support 1 and 2.

www.simcom.com 411 / 483


A76XX Series_AT Command Manual_V1.04

AT+CREC Record audio File


Response
Test Command +CREC: (0-3),[{non-ascii}]"FILEPATH"
AT+CREC=?
OK
Response
Read Command +CREC: (list current <status>s)
AT+CREC?
OK
Response
1)
+CREC: 1

OK
2)
Write Command +CREC: 2
AT+CREC=<record_path>,<file_
name> OK
3)
+CREC: 3

OK
4)
ERROR
Response
1)
+CREC: 0

OK
2)If it is recording:
Write Command
+CREC: 0
AT+CREC=<mode>

OK

+CREC: crec stop


3)
ERROR
Parameter Saving Mode
Max Response Time
Reference

Defined Values

<record_path> 1 local path

www.simcom.com 412 / 483


A76XX Series_AT Command Manual_V1.04

2 remote path (get voice from cs call)


3 mixd (local and remote)
<file_name> The name of wav/amr audio file.(MAX is 60 bytes)
<status> 0 free
1 busy
<mode> 0 stop record

Examples

AT+CREC=?
+CREC: (0-3),[{non-ascii}]"FILEPATH"

OK
AT+CREC?
+CREC: 0

OK
AT+CREC=1,"c:/recording.wav"
+CREC: 1

OK

+CREC: file full

AT+CREC=2,"c:/recording.wav"
+CREC: 2

OK

AT+CREC=0
+CREC: 0

OK

+CREC: crec stop

AT+CREC=1,"c:/recording.amr"
+CREC: 1

OK

+CREC: file full

AT+CREC=2,"c:/recording.amr"

www.simcom.com 413 / 483


A76XX Series_AT Command Manual_V1.04

+CREC: 2

OK

AT+CREC=0
+CREC: 0

OK

+CREC: crec stop

AT+CREC=3,"c:/recording3.amr"
+CREC: 3

OK

AT+CREC=0
+CREC: 0

OK

+CREC: crec stop

NOTE

 When the file is recoding full, Response "+CREC: file full " is displayed.
 Maximum size of wave file is 768KB and maximum size of amr file is 512KB.When the filesystem
free size is less than the maximum size of recording file,the maximum size of recording file is file
system free size.
 Mixd recording function(record_path set value 3) is just for A7600 Series(1600) and A7678
Series(1603).

www.simcom.com 414 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for FOTA

Overview of AT Command for FOTA

Command Description
AT+CFOTA Start FOTA Service
AT+LFOTA Start Local FOTA Service

NOTE

Currently, only CAT1 modules support at commands for FOTA.

Detailed Description of AT Command for FOTA

AT+CFOTA Start FOTA service

AT+CFOTA Start FOTA Service


Response
1)
Write Command
<CR><LF>OK<CR><LF>
AT+CFOTA=<channel>,<mo
de>,<destination_ip/url>,<us
+CFOTA: <err>
ername>,<password>
2)
<CR><LF>ERROR: <err><CR><LF>
Parameter Saving Mode NO_SAVE
Max Response Time -
Reference -

www.simcom.com 415 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<channel> 0–5 means the channel number


<mode> 0 FTP way
1 HTTP way
<destination_ip:port/url> The remote site server’s IP address or URL address.
IP address should be in the format of the dotted decimal notation:
XXX.XXX.XXX.XXX.
URL address should be ASCII characters, the maxmum of the
length is 255 bytes.

NOTE: If <port> are omitted, the default FTP port is 21 and the default
HTTP port is 80.
<username> The login user name, it should be ASCII characters, and the maxmum
of the length is 128 bytes.
<password> The login password, it should be ASCII characters, and the maxmum
of the length is 128 bytes.

Examples

AT+CFOTA=0,0,"183.230.174.137:6047/fbf_dfota.bin",simcom,simcom
+CFOTA: FOTA,START

+CFOTA: DOWNLOADING:17

+CFOTA: DOWNLOADING:50

+CFOTA: DOWNLOADING:83

+CFOTA: DOWNLOADING:99

+CFOTA: DOWNLOADING:100
AT+CFOTA=0,1," 183.230.174.137:6022/bin/fbf_dfota.bin",simcom,simcom
+CFOTA: FOTA,START

+CFOTA: DOWNLOADING:17

+CFOTA: DOWNLOADING:50

+CFOTA: DOWNLOADING:83

+CFOTA: DOWNLOADING:99

www.simcom.com 416 / 483


A76XX Series_AT Command Manual_V1.04

+CFOTA: DOWNLOADING:100

AT+LFOTA Start Local Fota Service

AT+LFOTA Start Local Fota Service


Response
Test Command +LFOTA=<0-1>,<File Size>
AT+LFOTA=?
OK
Response
1)if data pass check
+LFOTA: 1

OK
2)if data doesn’t pass check
Read Command
+LFOTA: 0
AT+LFOTA?

OK
3)if data has not transfer yet. It will be initial value -1
+LFOTA: -1

OK
Response
1)If successfully:
>
Write Command OK
AT+LFOTA=<ops>,<File 2)If failed:
Size> >
ERROR
3)If failed:
ERROR
Parameter Saving Mode -
Max Response Time -
Reference -

Defined Values

<ops> 0 initial parameters


1 start transfer
<File Size> The bytes of the file data to send.

www.simcom.com 417 / 483


A76XX Series_AT Command Manual_V1.04

Examples

AT+LFOTA=0,5358979
OK
AT+LFOTA=1,5358979
>
OK

NOTE

If UART is used for LFOTA, please make sure that the delay time between each 256 byte reach to at
least 50ms.

If sending file crash, restart module and increase the delay time between each 256 byte reach to 50ms,
and then try to send file again

Unsolicited Result Codes

URC Description
+CFOTA: 100 FOTA COMPLETE, it will restart in 8s.
+CFOTA: 1001 FOTA URL is invalid, maybe PDP was active.
+CFOTA: 1002 FOTA timeout
+CFOTA: 1003 FOTA URL is unknown
+CFOTA: 1004 FOTA username or password is error
+CFOTA: 1005 FOTA file is not exist
+CFOTA: 1006 The size of FOTA file is invalid
+CFOTA: 1007 Get file failed
+CFOTA: 1008 Check file error
+CFOTA: 1009 FOTA internal error
+CFOTA: 1010 Fota file too large
+CFOTA: 1011 Fota set flag error
+CFOTA: 1012 Fota parameter size error

www.simcom.com 418 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for SCFOTA


Overview of AT Commands for SCFOTA

Command Description
AT+CAPFOTA Start / Close FOTA service
AT+CSCFOTA Configure parameters and download upgrade package

NOTE

Currently, only CAT4 modules support at commands for SCFOTA

Detailed Description of AT Commands for SCFOTA

AT+CAPFOTA Start / Close FOTA service

AT+CAPFOTA Start / Close FOTA service


Response
Test Command +CAPFOTA: (0-1)
AT+CAPFOTA=?
OK
Response
1)
+CAPFOTA: 0

Read Command
OK
AT+CAPFOTA?
2)
+CAPFOTA: 1

OK

www.simcom.com 419 / 483


A76XX Series_AT Command Manual_V1.04

Response
Write Command 1)If successfully:
/*Setting FOTA service status*/ OK
AT+CAPFOTA=<on/off> 2)If failed:
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<on/off> The service status on/off, the default value is 0.


0 Close FOTA program
1 Active FOTA program
The function will take effect immediately.

Examples

AT+CAPFOTA=?
+CAPFOTA: (0-1)

OK
AT+CAPFOTA?
+CAPFOTA: 0

OK
AT+CAPFOTA=1
OK

AT+CSCFOTA Configure parameters and download upgrade package

AT+CSCFOTA Configure parameters and download upgrade package


Response
1)If successfully:
Write Command OK
AT+CSCFOTA=<OEM>,<models If it can be downloaded:
>,<product ID>,<product +CSCFOTA: 2
Secret>,<target version> +CSCFOTA: 3
If download partial is finished:
+CSCFOTA: 0

www.simcom.com 420 / 483


A76XX Series_AT Command Manual_V1.04

If there is no new version detected:


+CSCFOTA: 5
If detect version failed:
+CSCFOTA: <err>
If it cannot be downloaded:
+CSCFOTA: <err>
2)If failed:
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<OEM> The name of project design company. This name must be the same as
the OEM created on the cloud platform. Otherwise, it will cause
upgrade failed.
<models> The name of the device model. This name must be the same as the
device model created on the cloud platform. Otherwise, it will cause
upgrade failed.
<productID> The product ID that must be the same as the product ID generated on
the cloud platform.
<productSecret> The product secret is used to confirm the identity and usage rights of
the user. It must be the same as the product secret generated on the
cloud platform.
<target version> The version that needs to be upgraded to. This version is published by
the cloud platform.

Examples

AT+CSCFOTA="SIMCom","A7600C","1540907004","f9bbb0d76f894da090b6b69253616561","A760
0C_A39_190327_V1.00"
OK
+CSCFOTA: 2
+CSCFOTA: 3
+CSCFOTA: 0

Command Result Codes

www.simcom.com 421 / 483


A76XX Series_AT Command Manual_V1.04

Command Result Report Codes

Result codes Description


2 Check version is finished
3 Download is finished
4 Download partial finished
5 No new version

Description of <err>

<err> Description
0 OK
1 unknown error (contact supplier)
301 No enough memory
302 Invalid parameter
303 Invalid operation
304 IO failed
305 IO timeout
306 Download file verification failed
307 got canceled
308 Interface nesting error
401 Invalid device information
402 Invalid platform information
403 Missing device information
404 Version number is not configured
405 Internal error (contact supplier)
501 Invalid URL
502 Unable to resolve domain name
503 cannot connect to the server
504 Invalid request, server returned error
505 Not in range
506 HTTP POST request error
507 Re-download start error
508 Operation is aborted
509 Operation not completed
510 Too many retargeting times
511 Unable to get data from SOCKET
512 Error sending data via SOCKET

www.simcom.com 422 / 483


A76XX Series_AT Command Manual_V1.04

513 Error receiving data via SOCKET


514 Invalid SOCKET connection

www.simcom.com 423 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for GNSS


Overview of AT Commands for GNSS

Command Description
AT+CGNSSPWR GNSS power control
AT+CGPSCOLD Cold start GPS
AT+CGPSWARM Warm start GPS
AT+CGPSHOT Hot start GPS
AT+CGNSSIPR Configure the baud rate of UART3 and GPS module
AT+CGNSSMODE Configure GNSS support mode
AT+CGNSSNMEA Configure NMEA sentence type
AT+CGPSNMEARATE Set NMEA output rate
AT+CGPSFTM Start GPS test mode
AT+CGPSINFO Get GPS fixed position information
AT+CGNSSINFO Get GNSS fixed position information
AT+CGNSSCMD Send command to GNSS
AT+CGNSSTST Send data received from UART3 to NMEA port
AT+CGNSSPORTSWITCH Select the output port for NMEA sentence
AT+CAGPS Get AGPS data from the AGNSS server for assisted positioning

Detailed Description of AT Commands for GNSS

AT+CGNSSPWR GNSS power control

This command is used to control GNSS module by pulling up/down power pin.
Please enable GNSS by executing AT+CGNSSPWR=1.

AT+CGNSSPWR GNSS power control


Test Command Response
AT+CGNSSPWR=? +CGNSSPWR: (0,1)

www.simcom.com 424 / 483


A76XX Series_AT Command Manual_V1.04

OK
Response
Read Command +CGNSSPWR: 0/1
AT+CGNSSPWR?
OK
Response
1)If successfully:
Write Command
OK
AT+CGNSSPWR=<on/off>
2)If failed:
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<on/off> 0 Close GPS


1 Active GPS
The function will take effect immediately.

Examples

AT+CGNSSPWR=?
+CGNSSPWR: (0,1)

OK
AT+CGNSSPWR?
+CGNSSPWR: 0

OK
AT+CGNSSPWR=1
OK

AT+CGNSSTST Send data received from UART3 to NMEA port

This command is invalid when AT+CGNSSPWR=0.

AT+CGNSSTST Send data received from UART3 to NMEA port


Test Command Response

www.simcom.com 425 / 483


A76XX Series_AT Command Manual_V1.04

AT+CGNSSTST=? +CGNSSTST: (0,1)

OK
Response
Read Command +CGNSSTST: <on/off>
AT+CGNSSTST?
OK
Response
1)If successfully:
Write Command
OK
AT+CGNSSTST=<on/off>
2)If failed:
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<on/off> 0 Stop sending data received from UART3 to NMEA port.


1 Start sending data received from UART3 to NMEA port.
The function will take effect immediately.
This command is used for test, if you want to get NMEA data by NMEA
port, you should to excute AT+CGNSSTST=1 first.

Examples

AT+CGNSSTST=?
+CGNSSTST: (0,1)

OK
AT+CGNSSTST?
+CGNSSTST: 0

OK
AT+CGNSSTST=1
OK

AT+CGPSCOLD Cold start GPS

This command is invalid when AT+CGNSSPWR=0.

www.simcom.com 426 / 483


A76XX Series_AT Command Manual_V1.04

AT+CGPSCOLD Cold start GPS


Test Command Response
AT+CGPSCOLD=? OK
Execution Command Response
AT+CGPSCOLD OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Examples

AT+CGPSCOLD=?
OK
AT+CGPSCOLD
OK

AT+CGPSWARM Warm start GPS

This command is invalid when AT+CGNSSPWR=0.

AT+CGPSCOLD Cold start GPS


Test Command Response
AT+CGPSWARM =? OK
Execution Command Response
AT+CGPSWARM OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

NOTE

This command is valid on the A7678 Series projects.

Examples

AT+CGPSWARM=?
OK

www.simcom.com 427 / 483


A76XX Series_AT Command Manual_V1.04

AT+CGPSWARM
OK

AT+CGPSHOT Hot start GPS

This command is invalid when AT+CGNSSPWR=0.

AT+CGPSHOT Hot start GPS


Test Command Response
AT+CGPSHOT =? OK
Execution Command Response
AT+CGPSHOT OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Examples

AT+CGPSHOT =?
OK
AT+CGPSHOT
OK

AT+CGNSSIPR Configure the baud rate of UART3 and GPS module

This command is invalid when AT+CGNSSPWR=0.

AT+CGNSSIPR Configure the baud rate of UART3 and GPS module


Response
Test Command +CGNSSIPR: (4800,9600,19200,38400,57600,115200)
AT+CGNSSIPR=?
OK
Response
Read Command +CGNSSIPR: 9600
AT+CGNSSIPR?
OK
Write Command Response
AT+CGNSSIPR=<baud-rate> 1)If successfully:
www.simcom.com 428 / 483
A76XX Series_AT Command Manual_V1.04

OK
2)If failed:
ERROR
Response
Execution Command
Set default value 9600
AT+CGNSSIPR
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<baud-rate> 4800
9600
19200
38400
57600
115200
The function will take effect immediately.

NOTE

1. The baud-rate is supported by the A7678 Series projects:


9600, 115200 and 230400.
2. In the A7678 series project, the baud rate defaults to 115200 after GPS dynamic loading and
upgrading the firmware, and 9600 without GPS dynamic loading.

Examples

AT+CGNSSIPR=?
+CGNSSIPR: (4800,9600,19200,38400,57600,115200)

OK
AT+CGNSSIPR?
+CGNSSIPR: 9600

OK
AT+CGNSSIPR=4800
OK

www.simcom.com 429 / 483


A76XX Series_AT Command Manual_V1.04

AT+CGNSSMODE Configure GNSS support mode

This command is invalid when AT+CGNSSPWR=0.

AT+CGNSSMODE Configure GNSS support mode


Response
Test Command +CGNSSMODE: (1-7)
AT+CGNSSMODE=?
OK
Response
Read Command +CGNSSMODE: 3
AT+CGNSSMODE?
OK
Response
1)If successfully:
Write Command
OK
AT+CGNSSMODE=<mode>
2)If failed:
ERROR
Response
Execution Command
Set default value 3
AT+CGNSSMODE
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<mode> 1 GPS
2 BDS
3 GPS + BDS
4 GLONASS
5 GPS + GLONASS
6 BDS + GLONASS
7 GPS + BDS + GLONASS
The function will take effect immediately.

NOTE

The mode is supported by the A7678 Series projects:

1 GPS L1 + BDS B1 + QZSS


2 BDS B1

www.simcom.com 430 / 483


A76XX Series_AT Command Manual_V1.04

3 GPS L1+QZSS

Examples

AT+CGNSSMODE=?
+CGNSSMODE: (1-7)

OK
AT+CGNSSMODE?
+CGNSSMODE: 3

OK
AT+CGNSSMODE=1
OK

AT+CGNSSNMEA Configure NMEA sentence type

This command is invalid when AT+CGNSSPWR=0.

AT+CGNSSNMEA Configure NMEA sentence type


Response
+CGNSSNMEA:
Test Command (0-9),(0-9),(0-9),(0-9),(0-9),(0-9),(0-9),(0-9),(0-9),(0-9),(0-9),(0-9),(
AT+CGNSSNMEA=? 0-9),(0-9)

OK
Response
Read Command +CGNSSNMEA: 1,1,1,1,1,1,1,1,0,0,0,0,0,0
AT+CGNSSNMEA?
OK
Write Command Response
AT+CGNSSNMEA=[nGGA,[nGL 1)If successfully:
L,[nGSA,[nGSV,[nRMC,[nVTG,[ OK
nZDA,[nANT,[nDHV,[nLPS,[res1 2)If failed:
,[res2,[nUTC,[nGST]]]]]]]]]]]]]] ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

www.simcom.com 431 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

[nGGA,[nGLL,[nGSA,[nGSV, The range of n is 0-9. It means that the sentence is output every n
[nRMC,[nVTG,[nZDA,[nANT, times, 0 means no output, null means to save the original
[nDHV,[nLPS,[res1,[res2,[nU configuration.
TC,[nGST]]]]]]]]]]]]]] nGGA GGA output rate,default is 1
nGLL GLL output rate,default is 1
nGSA GSA output rate,default is 1
nGSV GSV output rate,default is 1
nRMC RMC output rate,default is 1
nVTG VTG output rate,default is 1
nZDA ZDA output rate,default is 1
nANT ANT output rate,default is 1
nDHV DHV output rate,default is 0
nLPS LPS output rate,default is 0(nonsupport)
res1 reserved,default is 0
res2 reserved,default is 0
nUTC UTC output rate,default is 0(nonsupport)
nGST GST output rate,default is 0
The function will take effect immediately.

NOTE

The NMEA fields are supported by the A7678 Series projects:

The range of n is 0-5. It means that the sentence is output every n times, 0 means no output, null
means to save the original configuration.
nGGA GGA output rate,default is 1
nGLL GLL output rate,default is 1
nGSA GSA output rate,default is 1
nGSV GSV output rate,default is 1
nRMC RMC output rate,default is 1
nVTG VTG output rate,default is 1
nZDA ZDA output rate,default is 0
nGST GST output rate,default is 0

Examples

AT+CGNSSNMEA=?
+CGNSSNMEA: (0-9),(0-9),(0-9),(0-9),(0-9),(0-9),(0-9),(0-9),(0-9),(0-9),(0-9),(0-9),(0-9),(0-9)

OK

www.simcom.com 432 / 483


A76XX Series_AT Command Manual_V1.04

AT+CGNSSNMEA?
+CGNSSNMEA: 1,1,1,1,1,1,1,1,0,0,0,0,0,0

OK
AT+CGNSSNMEA=1,0,0,0,0,0,0,0,0,0,,,1,1
OK

AT+CGPSNMEARATE Set NMEA output rate

This command is invalid when AT+CGNSSPWR=0.

AT+CGPSNMEARATE Set NMEA output rate


Response
Test Command +CGPSNMEARATE: (1,2,4,5,10)
AT+CGPSNMEARATE=?
OK
Response
Read Command +CGPSNMEARATE: 1
AT+CGPSNMEARATE?
OK
Response
1)If successfully:
Write Command
OK
AT+CGPSNMEARATE=<rate>
2)If failed:
ERROR
Response
Execution Command
Set default value 1
AT+CGPSNMEARATE
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<rate> 1 1Hz, one anchor point is output per second


2 2Hz, two anchor points is output per second
4 4Hz, four anchor points is output per second
5 5Hz, five anchor points is output per second
10 10Hz, ten anchor points is output per second
The function will take effect immediately.

www.simcom.com 433 / 483


A76XX Series_AT Command Manual_V1.04

NOTE

The rate is supported by the A7678 Series projects:

1 1Hz, one anchor point is output per second


2 2Hz, two anchor points is output per second
5 5Hz, five anchor points is output per second
10 10Hz, ten anchor points is output per second

Examples

AT+CGPSNMEARATE=?
+CGPSNMEARATE: (1,2,4,5,10)

OK
AT+CGPSNMEARATE?
+CGPSNMEARATE: 1

OK
AT+CGPSNMEARATE=4
OK

AT+CGPSFTM Start GPS test mode

This command is invalid when AT+CGNSSPWR=0.

AT+CGPSFTM Start GPS test mode


Test Command Response
AT+CGPSFTM=? OK
Response
Read Command +CGPSFTM: 0/1
AT+CGPSFTM?
OK
Response
1)If successfully:
Write Command
OK
AT+CGPSFTM=<on/off>
2)If failed:
ERROR
Parameter Saving Mode NO_SAVE

www.simcom.com 434 / 483


A76XX Series_AT Command Manual_V1.04

Max Response Time 9000ms


Reference -

Defined Values

<on/off> 0 Close test mode


1 Start test mode
The function will take effect immediately.

NOTE

GPGSV field and GBGSV field are supported by the A7678 Series projects.

Examples

AT+CGPSFTM?
+CGPSFTM: 0

OK
AT+CGPSFTM=1
OK
+GLGSV,78,20.6,66,25.6,77,21.6,79,21.9,67,26.2,
68,23.6
+GPGSV,10,36.3,12,33.5,14,26.5,15,27.0,18,30.6
,20,29.4,21,14.9,24,32.8,25,30.6,31,29.1,32,27.0
+BDGSV,201,28.7,204,29.0,206,27.3,207,25.9,20
9,25.0,210,18.5

AT+CGPSINFO Get GPS fixed position information

This command is invalid when AT+CGNSSPWR=0.

AT+CGPSINFO Get GPS fixed position information


Response
Test Command +CGPSINFO: (0-255)
AT+CGPSINFO=?
OK

www.simcom.com 435 / 483


A76XX Series_AT Command Manual_V1.04

Response
Read Command +CGPSINFO: <time>
AT+CGPSINFO?
OK
Response
1)If successfully:
OK
+CGPSINFO: [<lat>],[<N/S>],[<log>],[<E/W>],[<date>],[<UTC
Write Command
time>],[<alt>],[<speed>],[<course>]
AT+CGPSINFO=<time>
2)If <time>=0:
OK
3)If failed:
ERROR
Response
Execution Command +CGPSINFO: [<lat>],[<N/S>],[<log>],[<E/W>],[<date>],[<UTC
AT+CGPSINFO time>],[<alt>],[<speed>],[<course>]
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<time> The rang is 0-255, unit is second. after set <time> will report the GPS
information every the seconds.
The function will take effect immediately.
<lat> Latitude of current position. Output format is ddmm.mmmmmm.
<N/S> N/S Indicator, N=north or S=south.
<log> Longitude of current position. Output format is dddmm.mmmmmm.
<E/W> E/W Indicator, E=east or W=west.
<date> Date. Output format is ddmmyy.
<UTC time> UTC Time. Output format is hhmmss.s.
<alt> MSL Altitude. Unit is meters.
<speed> Speed Over Ground. Unit is knots.
<course> Course. Degrees.

Examples

AT+CGPSINFO=?
+CGPSINFO: (0-255)

OK

www.simcom.com 436 / 483


A76XX Series_AT Command Manual_V1.04

AT+CGPSINFO?
+CGPSINFO: 0

OK
AT+CGPSINFO
+CGPSINFO:3113.343286,N,12121.234064,E,250311,072809.3,44.1,0.0,0

OK

AT+CGNSSINFO Get GNSS fixed position information

This command is invalid when AT+CGNSSPWR=0.

AT+CGNSSINFO Get GNSS fixed position information


Response
Test Command +CGNSSINFO: (0-255)
AT+CGNSSINFO=?
OK
Response
Read Command +CGNSSINFO: <time>
AT+CGNSSINFO?
OK
Response
1)If successfully:
OK

+CGNSSINFO:
Write Command [<mode>],[<GPS-SVs>],[<GLONASS-SVs>],[BEIDOU-SVs],[<l
AT+CGNSSINFO=<time> at>],[<N/S>],[<log>],[<E/W>],[<date>],[<UTC-time>],[<alt>],[<s
peed>],[<course>],[<PDOP>],[HDOP],[VDOP]
2)If <time>=0:
OK
3)If failed:
ERROR
Response
+CGNSSINFO:
[<mode>],[<GPS-SVs>],[<GLONASS-SVs>],[BEIDOU-SVs],[<l
Execution Command
at>],[<N/S>],[<log>],[<E/W>],[<date>],[<UTC-time>],[<alt>],[<s
AT+CGNSSINFO
peed>],[<course>],[<PDOP>],[HDOP],[VDOP]

OK
Parameter Saving Mode NO_SAVE

www.simcom.com 437 / 483


A76XX Series_AT Command Manual_V1.04

Max Response Time 9000ms


Reference -

Defined Values

<time> The rang is 0-255, unit is second. after set <time> will report the
GNSS information every the seconds.
The function will take effect immediately.
<mode> Fix mode 2=2D fix 3=3D fix
<GPS-SVs> GPS satellite valid numbers scope: 00-12
<GLONASS-SVs> GLONASS satellite valid numbers scope: 00-12 (the A7678C project
do not support this field)
<BEIDOU-SVs> BEIDOU satellite valid numbers scope: 00-12
<lat> Latitude of current position. Output format is ddmm.mmmmmm.
<N/S> N/S Indicator, N=north or S=south.
<log> Longitude of current position. Output format is dddmm.mmmmmm.
<E/W> E/W Indicator, E=east or W=west.
<date> Date. Output format is ddmmyy.
<UTC-time> UTC Time. Output format is hhmmss.s.
<alt> MSL Altitude. Unit is meters.
<speed> Speed Over Ground. Unit is knots.
<course> Course. Degrees.
<PDOP> Position Dilution Of Precision.
<HDOP> Horizontal Dilution Of Precision.
<VDOP> Vertical Dilution Of Precision.

Examples

AT+CGNSSINFO=?
+CGNSSINFO: (0-255)

OK
AT+CGNSSINFO?
+CGNSSINFO: 0

OK
AT+CGNSSINFO
+CGNSSINFO:
2,09,05,00,3113.330650,N,12121.262554,E,131117,091918.0,32.9,0.0,255.0,1.1,0.8,0.7

OK
AT+CGNSSINFO (if not fix, will report null)
www.simcom.com 438 / 483
A76XX Series_AT Command Manual_V1.04

+CGNSSINFO:,,,,,,,,,,,,,,,
OK

NOTE

In the 7678 series projects, GLONASS satellites are not supported, so this command
<GLONASS-SVs> does not support.

AT+CGNSSCMD Send command to GNSS

This command is invalid when AT+CGNSSPWR=0.

AT+CGNSSCMD Send command to GNSS


Response
Test Command +CGNSSCMD: (0-1),"CmdString"
AT+CGNSSCMD=?
OK
Response
Write Command 1)If send OK:
AT+CGNSSCMD=<CmdType>,< OK
CmdString> 2)If send false:
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<CmdType> 0 NMEA style command.


1 HEX style command.
<CmdString> Command string, max length of string is 510.
For example: if you want to send "$PCAS02,1000*2E<CR><LF>"
command to GNSS.
You can use:
AT+CGNSSCMD=0,"$PCAS02,1000*2E"
Or:
AT+CGNSSCMD=1,"245043415330322C313030302A3245"

Examples
www.simcom.com 439 / 483
A76XX Series_AT Command Manual_V1.04

AT+CGNSSCMD=?
+CGNSSCMD: (0,1),"CmdString"

OK
AT+CGNSSCMD=0,"$PCAS02,1000*2E"
OK

AT+CGNSSPORTSWITCH Select the output port for NMEA sentence

This command is invalid when AT+CGNSSPWR=0. AT+CGNSSTST=1 is used to output original NMEA
data to USB NMEA port or UART port.

AT+CGNSSPORTSWITCH Select the output port for NMEA sentence


Response
Test Command +CGNSSPORTSWITCH: (0,1),(0,1)
AT+CGNSSPORTSWITCH=?
OK
Response
+CGNSSPORTSWITCH:
Read Command
<parse_data_port>,<nmea_data_port>
AT+CGNSSPORTSWITCH?

OK
Response
Write Command
1)If send OK:
AT+CGNSSPORTSWITCH=<par
OK
se_data_port>[,<nmea_data_po
2)If send false:
rt>]
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<parse_data_port> 0 output the parsed data of NMEA to USB AT port.


1 output the parsed data of NMEA to UART port.
<nmea_data_port> 0 output raw NMEA data to USB NMEA port.
1 output raw NMEA data to UART port.

Examples
www.simcom.com 440 / 483
A76XX Series_AT Command Manual_V1.04

AT+CGNSSPORTSWITCH=?
+CGNSSPORTSWITCH: (0,1),(0,1)

OK
AT+CGNSSPORTSWITCH=0,1
OK

AT+CAGPS Get AGPS data from the AGNSS server for assisted positioning

This command is invalid when AT+CGNSSPWR=0.

AT+CAGPS Get AGPS data from the AGNSS server for assisted positioning
Response
1)If successfully:
OK

+AGPS: success.
Execution Command
2)If failed:
AT+CAGPS
ERROR
3)If failed:
OK

+AGPS: <error code>.


Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<error code> 101 open socket unsuccessfully.


102 get the AGNSS server unsuccessfully.
103 connect to AGNSS server unsuccessfully.
104 write information to socket unsuccessfully.
105 read AGPS data from socket unsuccessfully.

Examples

AT+CAGPS
OK

www.simcom.com 441 / 483


A76XX Series_AT Command Manual_V1.04

+AGPS: success.

www.simcom.com 442 / 483


A76XX Series_AT Command Manual_V1.04

AT+CGNSSPROD Get the production of GNSS

This command is invalid when AT+CGNSSPWR=0.


AT+CGNSSPROD Get the production of GNSS
Response

Test Command
AT+CGNSSPROD=?
OK
Response
1)If successfully:
PRODUCTION: <prodname>
Execution Command
AT+CGNSSPROD
OK
2)If the GNSS is power off:
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -
Defined Values

<prodname> The production of GNSS,there are CASIC and UNICORECOMM


currently.
Examples

AT+CGNSSPROD=?
OK
AT+CGNSSPROD
PRODUCTION: CASIC

OK
AT+CGNSSPROD
PRODUCTION: UNICORECOMM

OK
AT+CGNSSPROD
ERROR

www.simcom.com 443 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for WIFI


Overview of AT Commands for WIFI

Command Description
AT+CWSTASCAN Scan WIFI network
AT+CWSTASCANEX Scan WIFI network extension command

Detailed Description of AT Commands for WIFI

AT+CWSTASCAN Scan WIFI network

AT+CWSTASCAN Scan WIFI network


Test Command Response
AT+CWSTASCAN=? +CWSTASCAN: (0-1)

OK
Read Command Response
AT+CWSTASCAN? +CWSTASCAN: <flag_show_signal>

OK
Write Command Response
AT+CWSTASCAN=<flag_sh 1)if the mode is 0 or 1:
ow_signal> OK
2)
ERROR
Execution Command Response
AT+CWSTASCAN [+CWSTASCAN: <bssid>,<channel_num>,[signal]
[……]]

OK
Parameter Saving Mode -
Max Response Time -
Reference

www.simcom.com 444 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<flag_show_signal> 0 Don’t show the signal level.


1 Show the signal level. It’s the default value.
<bssid> The MAC address of external wireless network.
<channel_num> The channel number of external wireless network.
<signal> The signal level of external wireless network.

Examples

AT+CWSTASCAN=?
+CWSTASCAN: (0-1)

OK
AT+CWSTASCAN=1
OK
AT+CWSTASCAN?
+CWSTASCAN: 1

OK
AT+CWSTASCAN
+CWSTASCAN:

50:FA:84:AF:C8:B9, 11, -61

86:40:BB:00:2E:AD, 11, -65

1C:15:1F:55:56:7A, 1, -76

B0:D5:9D:AF:57:A1, 6, -79

30:7B:AC:6C:F9:B0, 1, -81

OK

AT+CWSTASCANEX Scan WIFI network extension command

AT+CWSTASCANEX Scan WIFI network extension command


Test Command Response
www.simcom.com 445 / 483
A76XX Series_AT Command Manual_V1.04

AT+CWSTASCANEX=? +CWSTASCANEX: (0-1),(1-3),(4-10),(0-255),(0-1)

OK
Read Command Response
AT+CWSTASCANEX? +CWSTASCANEX:
<flag_show_signal>,<scan_round_num>,<scan_max_bssid_num
>,<scan_timeout>,<scan_priority>

OK
Write Command Response
AT+CWSTASCANEX=<flag_ 1)
show_signal>[,<scan_roun OK
d_num>[,<scan_max_bssid 2)
_num>[,<scan_timeout>[,<s ERROR
can_priority>]]]]
Execution Command Response
AT+CWSTASCANEX [+CWSTASCANEX: <bssid>,<channel_num>,[signal]
[… …]]

OK
Parameter Saving Mode -
Max Response Time -
Reference

Defined Values

<flag_show_signal> 0 Don’t show the signal level.


1 Show the signal level. It’s the default value.
<scan_round_num> The range is 1-3, means the number of rounds of WIFI scan.
<scan_max_bssid_num> The range is 4-10, maximum number of bssid per WIFI scan.
<scan_timeout> The range is 0-255, timeout.
<scan_priority> The range is 0-1, priority.
<bssid> The MAC address of external wireless network.
<channel_num> The channel number of external wireless network.
<signal> The signal level of external wireless network.

Examples

AT+CWSTASCANEX=?
+CWSTASCANEX: (0-1),(1-3),(4-10),(0-255),(0-1)

OK

www.simcom.com 446 / 483


A76XX Series_AT Command Manual_V1.04

AT+CWSTASCANEX=1,3,4,25,0
OK
AT+CWSTASCANEX?
+CWSTASCANEX: 1, 3, 4, 25, 0

OK
AT+CWSTASCANEX
+CWSTASCANEX:

08:4F:0A:CA:45:80, 6, -64

92:32:4B:9F:E2:EB, 1, -66

08:4F:0A:CA:45:40, 1, -79

1C:15:1F:FD:C7:6C, 6, -83

OK

www.simcom.com 447 / 483


A76XX Series_AT Command Manual_V1.04

AT Commands for Bluetooth

Overview of AT Commands for Bluetooth

Command Description
AT+BLEPOWER Power on/off Ble Device
AT+BLESTATUS Inquiry current BLE connect status
AT+BLEHOST Get or Set host name
AT+BLEADDR Inquiry Current Ble Address
AT+BLESREG Register GATT Server
AT+BLESDREG Deregister GATT Server
AT+BLESSAD Add a service
AT+BLESSRM Remove a service
AT+BLESSCAD Add a characteristic to an existed service
AT+BLESSCRM Remove a characteristic
AT+BLESSDAD Add a descriptor to an existed service
AT+BLESSDRM Remove a descriptor
AT+BLESSSTART Start a service
AT+BLESSSTOP Stop a service
AT+BLESSETADVDATA Set adverting package
AT+BLESCLRADVDATA Clear adverting package
AT+BLESLSTART Start advertising
AT+BLESLSTOP Stop advertising
AT+BLEADV Set adverting parameters
AT+BLEDISCONN Disconnect BLE connection
AT+BLESIND Send an indication to a client
AT+BLESNTY Send a notice to a client
AT+BLESRSP Send a Response to a Client’S Read or Write Operation
+BLESRREQ Read request received from remote device
+BLESWREQ Write request received from remote device
+BLESCON Notify When a Connection’s Status Change

NOTE

www.simcom.com 448 / 483


A76XX Series_AT Command Manual_V1.04

Currently, only A7678 Series support at commands for Bluetooth.

Detailed Description of AT Commands for Bluetooth

AT+BLEPOWER Power on/off Ble Device

AT+BLEPOWER=1 is used to power on ble device. You must execute AT+BLEPOWER=1 before any other
ble related operations.

AT+BLEPOWER Power on/off Ble Device


Test Command Response
AT+BLEPOWER=? OK
Response
+BLEPOWER: <status>
Read Command
AT+BLEPOWER? OK
Or
ERROR
Response
Write Command OK
AT+BLEPOWER=<op> Or
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 12000ms
Reference -

Defined Values

<status> This parameter has the following two values:


0 the current device is closed.
1 the current device is open.
<op> This parameter has the following two values:
0 power off the ble device
1 power on the ble device

Examples
www.simcom.com 449 / 483
A76XX Series_AT Command Manual_V1.04

AT+BLEPOWER=?
OK
AT+BLEPOWER=1
OK

AT+BLESTATUS Inquiry Current BLE Connect Status

AT+BLESTATUS Inquiry Current BLE Connect Status


Test Command Response
AT+BLESTATUS=? OK
Response
If ble has no connection:
OK
Read Command
else:
AT+BLESTATUS?
+BLESTATUS: <conn_id>,<gatts_type>,<user_id>,<addr>

OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<conn_id> The connection id of current connection


<gatts_type> The values are as follows:
0 None.
1 Gatt Server.
2 Gatt Client.
<user_id> User id of GATT server, or the name of the GATT server.A Hex value
string, each char of it should in set { ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’}.Length is 8.
<addr> Address of the peer device.

Examples

AT+BLESTATUS=?
OK
AT+BLESTATUS?
+BLESTATUS: 0,1,ABCDEF00,c0:65:29:48:56:ef
OK
www.simcom.com 450 / 483
A76XX Series_AT Command Manual_V1.04

AT+BLEHOST Inquiry and Set Host Device Name

AT+BLEHOST Inquiry and Set Host Device Name


Test Command Response
AT+BLEHOST=? OK
Response
Read Command +BLEHOST: <name>,<address>
AT+BLEHOST?
OK
Write Command Response
AT+BLEHOST=<name> OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<name> Device name, max length of it is 18 bytes


<address> Device address

Examples

AT+BLEHOST=?
OK
AT+BLEHOST?
+BLEHOST: SIMCOM BLE,”df:45:e6:29:65:c0”

OK
AT+BLEHOST=”SIMCOM BLE”
OK

AT+BLEADDR Inquiry Device Address

AT+BLEADDR Inquiry Device Address


Test Command Response

www.simcom.com 451 / 483


A76XX Series_AT Command Manual_V1.04

AT+BLEADDR=? OK
Response
Read Command +BLEADDR: <address>
AT+BLEADDR?
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<address> Device address

Examples

AT+BLEADDR=?
OK
AT+BLEADDR?
+BLEADDR: “df:45:e6:29:65:c0”

OK

AT+BLESREG Register GATT Server

AT+BLESREG Register GATT Server


Test Command Response
AT+BLESREG=? OK
Response
+BLESREG: <server_index>,<user_id>
Execution Command
AT+BLESREG OK
or
ERROR
Response
Read Command +BLESREG: <server_index>,<user_id>
AT+BLESREG?
OK
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms

www.simcom.com 452 / 483


A76XX Series_AT Command Manual_V1.04

Reference -

Defined Values

<server_index> Server index, the number of registered servers is limited to 64.


<user_id> User id of GATT server, or the name of the GATT server.
A Hex value string. Each char of it should in set
{ ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’ }. Length is 8.

Examples

AT+BLESREG=?
OK
AT+BLESREG
+BLESREG: 0, ABCDEF50

OK
AT+BLESREG?
+BLESREG: 0,ABCDEF50

OK

AT+BLESDREG Deregister GATT Server

AT+BLESDREG Deregister GATT Server


Test Command Response
AT+BLESDREG=? OK
Read Command Response
AT+BLESDREG? OK
Response
+BLESDREG: <server_index>,<user_id>
Write Command
AT+BLESDREG=<server_index
OK
>
or
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

www.simcom.com 453 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<server_index> Server index


<user_id> User id of GATT server, or the name of the GATT server.
A Hex value string. Each char of it should in set
{ ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’ }. Length is 8.

Examples

AT+BLESDREG=?
OK
AT+BLESDREG?
OK
AT+BLESDREG=0
+BLESDREG: 0,ABCDEF00

OK

AT+BLESSAD Add a Service

AT+BLESSAD Add a Service


Test Command Response
AT+BLESSAD=? OK
Response
If no service:
OK
Else
Write Command
+BLESSAD:
AT+BLESSAD=<server_index>,
<service_index>,<user_id>,<uuid>,<is_primary>,<inst>,<serv
<uuid>,<num_handles>,<is_pri
ice_handle>
mary>,<inst>

OK
or
ERROR
Response
+BLESSAD:
Read Command <service_index>,<user_id>,<uuid>,<is_primary>,<inst>,<serv
AT+BLESSAD? ice_handle>

OK
Parameter Saving Mode NO_SAVE

www.simcom.com 454 / 483


A76XX Series_AT Command Manual_V1.04

Max Response Time 9000ms


Reference -

Defined Values

<server_index> Server Index. Generated when the server is created.


<service_index> Service Index, the number of registered services is limited to 64.
<user_id> User id of GATT server, or the name of the GATT server.
A Hex value string. Each char of it should in set
{ ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’ }. Length is 8.
<uuid> The uuid of the service. Max length is 32.
<num_handles> Reserve.
<is_primary> The values are as follows:
1 primary service.
<inst> Not use.
<service_handle> The handle of this service. Dec format.

Examples

AT+BLESSAD=?
OK
AT+BLESSAD=0,”1802”,30,1,4
+BLESSAD: 0,ABCDEF50,1802,1,4,0

OK
AT+BLESSAD?
+BLESSAD: 0,ABCDEF50,1802,1,4,0

OK

AT+BLESSRM Remove a Service

AT+BLESSRM Remove a Service


Test Command Response
AT+BLESSRM=? OK
Read Command Response
AT+BLESSRM? OK
Write Command Response
AT+BLESSRM=<service_index> +BLESSRM:

www.simcom.com 455 / 483


A76XX Series_AT Command Manual_V1.04

<service_index>,<user_id>,<uuid>,<service_handle>

OK
or
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<service_index> Service Index


<user_id> User id of GATT server, or the name of the GATT server.
A Hex value string. Each char of it should in set
{ ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’ }. Length is 8.
<uuid> The UUID of the service, a string with hex value, length is 4.
<service_handle> The handle of this service. Dec format.

Examples

AT+BLESSRM=?
OK
AT+BLESSRM?
OK
AT+BLESSRM=0
+BLESSRM: 0,ABCDEF50,1802,0

OK

AT+BLESSCAD Add a Characteristic to an Existed Service

AT+BLESSCAD Add a Characteristic to an Existed Service


Test Command Response
AT+BLESSCAD=? OK
Response
If no characteristic:
Read Command
OK
AT+BLESSCAD?
Else
+BLESSCAD:

www.simcom.com 456 / 483


A76XX Series_AT Command Manual_V1.04

<char_index>,<user_id>,<char_uuid>,<inst>,<prop>,<permis
sion>,<char_handle>

OK
Response
+BLESSCAD:
Write Command
<char_index>,<user_id>,<char_uuid>,<inst>,<char_handle>
AT+BLESSCAD=<service_inde
x>,<char_uuid>,<inst>,<pro
OK
p>,<permission>
or
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<service_index> Service Index


<char_index> Characteristic index, the number of registered characteristics is limited
to 64.
<user_id> User id of GATT server, or the name of the GATT server. A Hex value
string. Each char of it should in set { ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’ }. Length is 8.
<char_uuid> The UUID of the characteristic. Max length is 32.
<service_handle> The handle of this service. Dec format.
<inst> Not use.
<prop> Properties of this characteristic. Dec format.
It should be a combination of the following values:
Default 0
Broadcast 1
Read 2
Write without response 4
Write 8
Notify 16
Indicate 32
Signed write 64
Extended properties 128
<permission> Permission of this characteristic.
It should be a combination of the following values:
Read 1
Write 2
<char_handle> The handle of this Characteristic. Dec format.

Examples
www.simcom.com 457 / 483
A76XX Series_AT Command Manual_V1.04

AT+BLESSCAD=?
OK
AT+BLESSCAD=0,"2A06",4,38,3
+BLESSCAD: 0,ABCDEF50,2A06,4,0

OK
AT+BLESSCAD?
+BLESSCAD: 0,ABCDEF50,2A06,4,38,3,0

OK

AT+BLESSCRM Remove a Characteristic

AT+BLESSCRM Remove a Characteristic


Test Command Response
AT+BLESSCRM=? OK
Response
+BLESSCRM:
<char_index>,<user_id>,<char_uuid>
Write Command
AT+BLESSCRM=<char_index>
OK
or
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<char_index> Characteristic index


<user_id> User id of GATT server, or the name of the GATT server. A Hex value
string. Each char of it should in set { ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’ }. Length is 8.
<char_uuid> The UUID of the characteristic, a string with hex value, length is 4.

Examples

AT+BLESSCRM=?
OK
AT+BLESSCRM=0
www.simcom.com 458 / 483
A76XX Series_AT Command Manual_V1.04

+BLESSCRM: 0,ABCDEF50,2A06

OK

AT+BLESSDAD Add a Descriptor to an Existed Service

AT+BLESSDAD Add a Descriptor to an Existed Service


Test Command Response
AT+BLESSDAD=? OK
Response
If no descriptor
OK
Else
Read Command
+BLESSDAD:
AT+BLESSDAD?
<desc_index>,<user_id>,<service_handle>,<desc_uuid>,<ins
t>,<permission>,<desc_handle>

OK
Response
+BLESSDAD:
Write Command <desc_index>,<char_uuid> ,<desc_uuid>,<inst>,<desc_handl
AT+BLESSDAD=<char_index e>
>,<desc_uuid>,<inst>,<pe
rmission> OK
or
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<char_index> Characteristic index


<desc_index> Descriptor Index, the number of registered desciptor is limited to 64.
<char_uuid> The UUID of the characteristic, Max length is 32.
<desc_uuid> The UUID of the descriptor, Max length is 32.
<inst> Not use.
<permission> Permission of this characteristic. Dec format.
It should be a combination of the following values:
Read 1

www.simcom.com 459 / 483


A76XX Series_AT Command Manual_V1.04

Write 2
<desc_handle> Handle of this descriptor. Dec format.

Examples

AT+BLESSDAD=?
OK
AT+BLESSDAD=0,"0210",4,0
+BLESSDAD: 0,1802,0210,0,0

OK

AT+BLESSDRM Remove a Descriptor

AT+BLESSDRM Add a Descriptor to an Existed Service


Test Command Response
AT+BLESSDRM=? OK
Response
+BLESSDRM: <desc_index>,<desc_uuid>
Write Command
AT+BLESSDRM=<desp_index> OK
or
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<desc_index> Descriptor Index


<desc_uuid> The UUID of the descriptor, a string with hex value, length is 4.

Examples

AT+BLESSDRM=?
OK
AT+BLESSDRM=0
+BLESSDRM: 0,0210

www.simcom.com 460 / 483


A76XX Series_AT Command Manual_V1.04

OK

AT+BLESSSTART Start a Service

AT+BLESSSTART Start a Service


Test Command Response
AT+BLESSSTART=? OK
Response
If no started device:
OK
Read Command
Else
AT+BLESSSTART?
+BLESSSTART: <service_index>,<user_id>,<service_handle>

OK
Response
+BLESSSTART: <service_index>,<user_id>,<service_handle>
Write Command
AT+BLESSSTART=<service_ind
OK
ex>,<transport>
or
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<service_index> Service index. Generated when the service is created.


<transport> Not use.
<user_id> User id of GATT server, or the name of the GATT server. A Hex value
string. Each char of it should in set { ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’ }. Length is 8.
<service_handle> The handle of this service. Dec format.

Examples

AT+BLESSSTART=?
OK
AT+BLESSSTART=0,0
+BLESSSTART: 0,ABCDEF50,0

www.simcom.com 461 / 483


A76XX Series_AT Command Manual_V1.04

OK

AT+BLESSSTOP Stop a Service

AT+BLESSSTOP Stop a Service


Test Command Response
AT+BLESSSTOP=? OK
Read Command Response
AT+BLESSSTOP? OK
Response
+BLESSSTOP: <service_index>,<user_id>,<service_handle>
Write Command
AT+BLESSSTOP=<service_inde
OK
x>
or
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<service_index> Service index


<transport> Transport way to start service.
0 LE
<user_id> User id of GATT server, or the name of the GATT server.A Hex value
string. Each char of it should in set { ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’ }. Length is 8.
<service_handle> The handle of this service. Dec format.

Examples

AT+BLESSSTOP=?
OK
AT+BLESSSTOP?
OK
AT+BLESSSTOP=0
+BLESLSTOP: 0,ABCDEF50,0

OK

www.simcom.com 462 / 483


A76XX Series_AT Command Manual_V1.04

AT+BLESSETADVDATA Set Adverting Package

This command is incompatible with the +BLEHOST and +BLEADV command. If the above commands are
used at same time, only this command will take effect.

AT+BLESSETADVDATA Set Adverting Package


Response
Test Command +BLESSETADVDATA: <server_index>,<type>,<value>
AT+BLESSETADVDATA=?
OK
Response
1)if <type> and <value> is ignored:
+BLESSETDAVDATA: <adv_data>
Write Command
AT+BLESSSTOP=<server_inde OK
x>[,<type>,<value>] 2)else:
OK
or
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<server_index> Server index, generated when the server is register.


<type> LE adverting package type, consistent with Bluetooth standard
documents.
<value> LE adverting package data. String Type, max length is 29. If the format
is the same as HEX{DATA}, and DATA is a hexadecimal string, DATA
will be transcoded and set.
<adv_data> Adverting package currently set, is a hexadecimal string.

Examples

AT+BLESSETADVDATA=?
+BLESSETADVDATA:
<server_index>,<type>,<value>

OK
AT+BLESSETADVDATA=0
www.simcom.com 463 / 483
A76XX Series_AT Command Manual_V1.04

+BLESSETADVDATA:

OK
AT+BLESSETADVDATA=0,1,”HEX{01}”
OK

AT+BLESCLRADVDATA Clear Adverting package

This command is only used to clear the adverting package set by +BLESSETADVDATA command.

AT+BLESCLRADVDATA Clear Adverting package


Test Command Response
AT+BLESCLRADVDATA=? OK
Response
Write Command
OK
AT+BLESCLRADVDATA=<serve
or
r_index>
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<server_index> Service index, generated when the server is register.

Examples

AT+BLESCLRADVDATA=?
OK
AT+BLESCLRADVDATA=0
OK

AT+BLESLSTART Start Advertising

AT+BLESLSTART Start Advertising


Test Command Response
AT+BLESLSTART=? OK

www.simcom.com 464 / 483


A76XX Series_AT Command Manual_V1.04

Response
If no device in adversing.
OK
Read Command
Else
AT+BLESLSTART?
+BLESLSTART: <server_index>,<user_id>

OK
Response
+BLESLSTART: <server_index>,<user_id>
Write Command
AT+BLESLSTART=<server_inde
OK
x>
or
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<server_index> Server index


<user_id> User id of GATT server, or the name of the GATT server.A Hex value
string, each char of it should in set { ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’}.Length is 8.

Examples

AT+BLESLSTART=?
OK
AT+BLESLSTART=0
+BLESLSTART: 0,ABCDEF50

OK

AT+BLESLSTOP Stop Advertising

AT+BLESLSTOP Stop Advertising


Test Command Response
AT+BLESLSTOP=? OK
Read Command Response
AT+BLESLSTOP? OK
Write Command Response
www.simcom.com 465 / 483
A76XX Series_AT Command Manual_V1.04

AT+BLESLSTOP=<service_inde +BLESLSTOP: <server_index>,<user_id>


x>
OK
or
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<server_index> Server index


<user_id> User id of GATT server, or the name of the GATT server.A Hex value
string, each char of it should in set { ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’}.Length is 8.

Examples

AT+BLESLSTOP=?
OK
AT+BLESLSTOP=0
+BLESLSTOP: 0,ABCDEF50

OK

AT+BLEADV Set Adverting Parameters

AT+BLEADV Set Adverting Parameters


Test Command Response
AT+BLEADV=? OK
Write Command Response
AT+BLEADV=<server_index>,< +BLEADV: <user_id>
scan_rsp>,<include_name>,<in
clude_txpower>,<appearance>[ OK
,<manufacturer_data>,<service or
_data>,<service_uuid>] ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

www.simcom.com 466 / 483


A76XX Series_AT Command Manual_V1.04

Defined Values

<server_index> Server index


<user_id> User id of GATT server, or the name of the GATT server.A Hex value
string, each char of it should in set { ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’}.Length is 8.
<scan_rsp> Include flag parameter or not
0 Not include
1 Include
<include_name> Include BT name
0 Not include
1 Include
<include_txpower> Include Tx power Level
0 Not include
1 Include
<appearance> Set appearance,0~16384
<manufacturer_data> Set manufacturer, A Hex value string, each
char of it should in set { ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’}.Max length of it is 56.
<service_data> Set service_data uuid, A Hex value string, each char
of it should in set { ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’}.The length of it should be 0 or
4~32.
<service_uuid> Set complete services uuid, A Hex value string, each
char of it should in set { ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’}. The length of it should be
0 or 4~32.

Examples

AT+BLEADV=?
OK
AT+BLEADV=0,1,1,1,0
+BLEADV: ABCDEF50

OK

AT+BLEDISCONN Disconnect BLE Connection

AT+BLEDISCONN Disconnect BLE Connection


Test Command Response
AT+BLEDISCONN=? OK
Read Command Response
AT+BLEDISCONN? OK
Write Command Response

www.simcom.com 467 / 483


A76XX Series_AT Command Manual_V1.04

AT+BLEDISCONN=<conn_id> OK

+BLESCON: <op>,<user_id>,<addr>,<conn_id>
or
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

<op> 0 Disconnect
1 Connect
<conn_id> The connection id of current connection
<addr> Address of the peer device.
<user_id> User id of GATT server, or the name of the GATT server.A Hex value
string, each char of it should in set { ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’}.Length is 8.

Examples

AT+BLEDISCONN=?
OK
AT+BLEDISCONN=0
OK

+BLESCON:
0,ABCDEF50,”df:45:e6:29:65:c1”,0

AT+BLESIND Send an Indication to a Client

AT+BLESIND Send an Indication to a Client


Test Command Response
AT+BLESIND=? OK
Response
+BLESIND: <result>,<user_id>,<conn_id>,<attr_handle>
Write Command
AT+BLESIND=<char_index>,<v
OK
alue>
or
ERROR

www.simcom.com 468 / 483


A76XX Series_AT Command Manual_V1.04

Parameter Saving Mode NO_SAVE


Max Response Time 9000ms
Reference -

Defined Values

<char_index> Characteristic index


<user_id> User id of GATT server, or the name of the GATT server.A Hex value
string, each char of it should in set { ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’ }.Max length of
it is 8.
<conn_id> The connection id of current connection.
<attr_handle> The handle of the characteristic value. Dec format.
<value> The value need to be notified. String Type, max length is 181. If the
format is the same as HEX{DATA}, and DATA is a hexadecimal string,
DATA will be transcoded and sent.
<result> 0 Success
1 Fail

Examples

AT+BLESIND=?
OK
AT+BLESIND=0,”HEX{123456}”
+BLESIND: 0,ABCDEF00,1,17

OK

AT+BLESNTY Send an notice to a Client

AT+BLESNTY Send an Notice to a Client


Test Command Response
AT+BLESNTY=? OK
Response
+BLESNTY: <result>,<user_id>,<conn_id>,<attr_handle>
Write Command
AT+BLESNTY=<char_index>,<v
OK
alue>
or
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms

www.simcom.com 469 / 483


A76XX Series_AT Command Manual_V1.04

Reference -

Defined Values

<char_index> Characteristic index


<user_id> User id of GATT server, or the name of the GATT server.A Hex value
string, each char of it should in set { ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’ }.Max length of
it is 8.
<conn_id> The connection id of current connection.
<attr_handle> The handle of the characteristic value. Dec format.
<value> The value need to be notified. String Type, max length is 181. If the
format is the same as HEX{DATA}, and DATA is a hexadecimal string,
DATA will be transcoded and sent.
<result> 0 Success
1 Fail.

Examples

AT+BLESNTY=?
OK
AT+BLESNTY=0,”HEX{123456}”
+BLESNTY: 0,ABCDEF00,1,17

OK

AT+BLESRSP Send a Response to a Client’S Read or Write Operation

AT+BLESRSP Send a Response to a Client’S Read or Write Operation


Response
+BLESRSP: <result>,<user_id>,<conn_id>,<attr_handle>
Write Command
AT+BLESRSP=<switch>,<value
OK
>
or
ERROR
Parameter Saving Mode NO_SAVE
Max Response Time 9000ms
Reference -

Defined Values

www.simcom.com 470 / 483


A76XX Series_AT Command Manual_V1.04

<switch> 0 Read
1 Write
<user_id> User id of GATT server, or the name of the GATT server.A Hex value
string, each char of it should in set { ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’ }.Max length of
it is 8.
<conn_id> The connection id of current connection.
<attr_handle> The handle of the characteristic value. Dec format.
<value> The value need to response read request. String Type, max length is
181. If the format is the same as HEX{DATA}, and DATA is a
hexadecimal string, DATA will be transcoded and sent.
<result> 0 Success
1 Fail

Examples

AT+BLESRSP=0,”HEX{123456}”
+BLESRSP: 0,ABCDEF50,1,17

OK

+BLESRREQ Read request received from remote device

AT+BLESRREQ Read request received from remote device


URC
if there is incoming a read request:
+BLESRREQ:
<user_id>,<conn_id>,<trans_id>,<addr>,<attr_handle>,<is_lo
ng>,<offset>
Reference -

Defined Values

<user_id> User id of GATT server, or the name of the GATT server.A Hex value
string, each char of it should in set
{ ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’ }.Max length of it is 8.
<conn_id> The connection id of current connection.
<trans_id> The id of current transaction.0~65535
<addr> Address of the peer device.
<attr_handle> Handle of attribute.
<is_long> Tell server that the request is one or several requests.
<offset> Offset of the request.0~65535

www.simcom.com 471 / 483


A76XX Series_AT Command Manual_V1.04

Examples

+BLESRREQ:
ABCDEF50,1,0,"90:f0:6a:3a:4f:41",17,19,0

+BLESWREQ Write request received from remote device

AT+BLESWREQ Write request received from remote device


URC
if there is incoming a write request:
+BLESWREQ:
<user_id>,<conn_id>,<trans_id>,<addr>,<attr_handle>,<value
>,<need_rsp>,<is_prep>,<offset>
Reference -

Defined Values

<user_id> User id of GATT server, or the name of the GATT server.A Hex value
string, each char of it should in set
{ ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’ }.Max length of it is 8.
<conn_id> The connection id of current connection.
<trans_id> The id of current transaction.0~65535
<addr> Address of the peer device.
<attr_handle> Handle of attribute.
<value> The value need to be write, Hex format
<need_rsp> Whether client need server's response
1 Yes
0 No
<is_prep> Whether or not server execute request immediately
0 No
1 Yse
<offset> Offset of the request.0~65535

Examples

+BLESWREQ: ABCDEF50,1,0,"21:e8:5a:c2:8d:47",17,1234,0,0,0

www.simcom.com 472 / 483


A76XX Series_AT Command Manual_V1.04

+BLESCON Notify When a Connection’s Status Change

Notify When Connection’s Status Change


Response
+BLESCON: <op>,<user_id>,<addr>,<conn_id>
Reference -

Defined Values

<op> 0 Disconnect
1 Connect
<user_id> User id of GATT server, or the name of the GATT server.A Hex value
string, each char of it should in set{ ‘0’~‘9’,‘a’~‘f’,‘A’~‘F’ }.Max length of
it is 8.
<addr> Address of the peer device.
<conn_id> The connection id of current connection.

Examples

+BLESCON: 1,ABCDEF50,21:e8:5a:c2:8d:47,1

www.simcom.com 473 / 483


A76XX Series_AT Command Manual_V1.04

Summary of ERROR Codes


Verbose Codes and Numeric Codes

Verbose result code Numeric (V0 set) Description


OK 0 Command executed, no errors, Wake up after
reset
CONNECT 1 Link established
RING 2 Ring detected
NO CARRIER 3 Link not established or disconnected
ERROR 4 Invalid command or command line too long
NO DIALTONE 6 No dial tone, dialing impossible, wrong mode
BUSY 7 Remote station busy
NO ANSWER 8 Connection completion timeout

Response String of AT+CEER

Number Response string


CS internal cause
0 Unknown
1 Unassigned number
3 No route to destination
6 Channel unacceptable
8 Operator determined barring
16 Normal call clearing
17 User busy
18 No user responding
19 User alerting: no answer
21 Call rejected
22 Number changed
25 Preemption
26 Non selected user clearing
27 Destination out of order
www.simcom.com 474 / 483
A76XX Series_AT Command Manual_V1.04

28 Invalid number format


29 Facility rejected
30 Response to STATUS ENQUIRY
31 Normal unspecified
34 No circuit/channel available
38 Network out of order
41 Temporary failure
42 Switching equipment congestion
43 Access information discarded
44 Requested circuit/channel unavailable
47 Resource unavailable
49 QoS unavailable
50 Requested facility not subscribed
55 Incoming calls barred within CUG
57 Bearer capability not authorized
58 Bearer capability not available
63 Service not available
65 Bearer service not implemented
68 ACM MAX reached
69 Facility not implemented
70 Only RDI bearer capability available
79 Service not implemented
81 Invalid transaction ID
87 User not member of CUG
88 Incompatible destination
91 Invalid transit network selection
95 Incorrect message
96 Invalid mandatory information
97 Message type non-existent
98 Message type wrong state
99 Information element not-existent
100 Conditional IE error
101 Message wrong state
102 Recovery after timer expiry
111 Protocol error: unspecified
127 Interworking: unspecified
224 Call barring
241 FDN Blocked

CS network cause
1 Unassigned/unallocated number

www.simcom.com 475 / 483


A76XX Series_AT Command Manual_V1.04

3 No route to destination
6 Channel unacceptable
8 Operator determined barring
16 Normal call clearing
17 User busy
18 No user responding
19 User alerting, no answer
21 Call rejected
22 Number changed
26 Non selected user clearing
27 Destination out of order
28 Invalid/incomplete number
29 Facility rejected
30 Response to Status Enquiry
31 Normal, unspecified
34 No circuit/channel available
38 Network out of order
41 Temporary failure
42 Switching equipment congestion
43 Access information discarded
44 Requested circuit/channel not available
47 Resources unavailable, unspecified
49 Quality of service unavailable
50 Requested facility not subscribed
55 Incoming calls barred within the CUG
57 Bearer capability not authorized
58 Bearer capability not available
63 Service/option not available
65 Bearer service not implemented
68 ACM >= ACMmax
69 Requested facility not implemented
70 Only RDI bearer is available
79 Service/option not implemented
81 Invalid transaction identifier value
87 User not member of CUG
88 Incompatible destination
91 Invalid transit network selection
95 Semantically incorrect message
96 Invalid mandatory information
97 Message non-existent/not implemented
98 Message type not compatible with state

www.simcom.com 476 / 483


A76XX Series_AT Command Manual_V1.04

99 IE non-existent/not implemented
100 Conditional IE error
101 Message not compatible with state
102 Recovery on timer expiry
111 Protocol error, unspecified
117 Interworking, unspecified

CS network reject
2 IMSI unknown in HLR
3 Illegal MS
4 IMSI unknown in VLR
5 IMEI not accepted
6 Illegal ME
7 GPRS services not allowed
8 GPRS & non GPRS services not allowed
9 MS identity cannot be derived
10 Implicitly detached
11 PLMN not allowed
12 Location Area not allowed
13 Roaming not allowed
14 GPRS services not allowed in PLMN
15 No Suitable Cells In Location Area
16 MSC temporarily not reachable
17 Network failure
20 MAC failure
21 Synch failure
22 Congestion
23 GSM authentication unacceptable
32 Service option not supported
33 Requested service option not subscribed
34 Service option temporarily out of order
38 Call cannot be identified
40 No PDP context activated
95 Semantically incorrect message
96 Invalid mandatory information
97 Message type non-existent
98 Message type not compatible with state
99 Information element non-existent
101 Message not compatible with state
161 RR release indication
162 RR random access failure

www.simcom.com 477 / 483


A76XX Series_AT Command Manual_V1.04

163 RRC release indication


164 RRC close session indication
165 RRC open session failure
166 Low level failure
167 Low level failure no redial allowed
168 Invalid SIM
169 No service
170 Timer T3230 expired
171 No cell available
172 Wrong state
173 Access class blocked
174 Abort message received
175 Other cause
176 Timer T303 expired
177 No resources
178 Release pending
179 Invalid user data

PS internal cause lookup


0 Invalid connection identifier
1 Invalid NSAPI
2 Invalid Primary NSAPI
3 Invalid field
4 SNDCP failure
5 RAB setup failure
6 No GPRS context
7 PDP establish timeout
8 PDP activate timeout
9 PDP modify timeout
10 PDP inactive max timeout
11 PDP lowerlayer error
12 PDP duplicate
13 Access technology change
14 PDP unknown reason

PS network cause
25 LLC or SNDCP failure
26 Insufficient resources
27 Missing or unknown APN
28 Unknown PDP address or PDP type
29 User Aauthentication failed

www.simcom.com 478 / 483


A76XX Series_AT Command Manual_V1.04

30 Activation rejected by GGSN


31 Activation rejected, unspecified
32 Service option not supported
33 Requested service option not subscribed
34 Service option temporarily out of order
35 NSAPI already used (not sent)
36 Regular deactivation
37 QoS not accepted
38 Network failure
39 Reactivation required
40 Feature not supported
41 Semantic error in the TFT operation
42 Syntactical error in the TFT operation
43 Unknown PDP context
44 PDP context without TFT already activated
45 Semantic errors in packet filter
46 Syntactical errors in packet filter
81 Invalid transaction identifier
95 Semantically incorrect message
96 Invalid mandatory information
97 Message non-existent/not implemented
98 Message type not compatible with state
99 IE non-existent/not implemented
100 Conditional IE error
101 Message not compatible with state
111 Protocol error, unspecified

Summary of CME ERROR Codes

This result code is similar to the regular ERROR result code. The format of <err> can be either numeric or
verbose string, by setting AT+CMEE command.

Defined Values

Code of <err> Meaning


0 phone failure
1 no connection to phone

www.simcom.com 479 / 483


A76XX Series_AT Command Manual_V1.04

2 phone adaptor link reserved


3 operation not allowed
4 operation not supported
5 PH- SIM PIN required
6 PH-FSIM PIN required
7 PH-FSIM PUK required
10 SIM not inserted
11 SIM PIN required
12 SIM PUK required
13 SIM failure
14 SIM busy
15 SIM wrong
16 incorrect password
17 SIM PIN2 required
18 SIM PUK2 required
20 memory full
21 invalid index
22 not found
23 memory failure
24 text string too long
25 invalid characters in text string
26 dial string too long
27 invalid characters in dial string
30 no network service
31 network timeout
32 network not allowed - emergency calls only
40 network personalization PIN required
41 network personalization PUK required
42 network subset personalization PIN required
43 network subset personalization PUK required
44 service provider personalization PIN required
45 service provider personalization PUK required
46 corporate personalization PIN required
47 corporate personalization PUK required
50 Incorrect parameters
100 unknown error
103 Illegal MESSAGE
106 Illegal ME
107 GPRS services not allowed
111 PLMN not allowed
112 Location area not allowed

www.simcom.com 480 / 483


A76XX Series_AT Command Manual_V1.04

113 Roaming not allowed in this location area


132 service option not supported
133 requested service option not subscribed
134 service option temporarily out of order
148 unspecified GPRS error
149 PDP authentication failure
150 invalid mobile class
151 AT command timeout

Examples

AT+CPIN="1234","1234"
+CME ERROR: SIM failure

Summary of CMS ERROR Codes

Final result code +CMS ERROR: <err> indicates an error related to mobile equipment or network. The
operation is similar to ERROR result code. None of the following commands in the same command line is
executed. Neither ERROR nor OK result code shall be returned. ERROR is returned normally when error is
related to syntax or invalid parameters. The format of <err> can be either numeric or verbose. This is set
with command AT+CMEE.

Defined Values

Code of <err> Meaning


300 ME failure
301 SMS service of ME reserved
302 Operation not allowed
303 Operation not supported
304 Invalid PDU mode parameter
305 Invalid text mode parameter
310 SIM not inserted
311 SIM PIN required
312 PH-SIM PIN required
313 SIM failure
314 SIM busy
315 SIM wrong

www.simcom.com 481 / 483


A76XX Series_AT Command Manual_V1.04

316 SIM PUK required


317 SIM PIN2 required
318 SIM PUK2 required
320 Memory failure
321 Invalid memory index
322 Memory full
330 SMSC address unknown
331 no network service
332 Network timeout
340 NO +CNMA ACK EXPECTED
341 Buffer overflow
342 SMS size more than expected
500 unknown error

Examples

AT+CMGS=02112345678
+CMS ERROR: 304

www.simcom.com 482 / 483