0% found this document useful (0 votes)
141 views

Hemodynamic Monitoring Systems

The document compares hemodynamic monitoring systems from various companies. It provides information on products, features, FDA clearance, number of systems installed, and key differentiating features from GE Healthcare, Philips Healthcare, and Siemens Healthcare. Specifications covered include channels for pressures, ECG, and plug-in modules. Display options are also listed.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
141 views

Hemodynamic Monitoring Systems

The document compares hemodynamic monitoring systems from various companies. It provides information on products, features, FDA clearance, number of systems installed, and key differentiating features from GE Healthcare, Philips Healthcare, and Siemens Healthcare. Specifications covered include channels for pressures, ECG, and plug-in modules. Display options are also listed.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Hemodynamic Monitoring Systems

Company GE Healthcare GE Healthcare Philips Healthcare Siemens Healthcare Siemens Healthcare

Product Mac-Lab Cardiac Cath Lab Physiological Recording System ComboLab Combined Electrophysiology and Hemodynamic Recording System Philips Hemo System with IntelliVue X3 and Xper Information Management System Sensis Vibe Hemo Sensis Vibe Hemo + EP 32 64 96
FDA cleared / CE mark (year) Yes Yes 2019 2015 2015
Number of systems installed in U.S. Yes Yes 300 1070 10
What are the key differentiating features of your system There are ~4000 invasive systems installed in the USA There are ~4000 invasive systems installed in the USA The Philips Interventional Hemodynamic system brings advanced hemodynamic measurements to the cathlab and provides a comprehensive scalable Efficient Macros workflow and solutions; hemodynamic or EP monitoring in the same system. Multi-vendor Efficient Macros workflow and solutions; hemodynamic or EP monitoring in the same system.
physiomonitoring and data management solution for interventional and hybrid OR environments. Philips Hemo system is integrated with your Philips integrated FFR with report inclusion function. Automated systolic area index calculations. Integration with 32 64 or 96 IECG channels. Generic RFA and Stimulator interface Integration with Siemens
Interventional X-ray system and Xper Information Management (IM) to streamline lab workflow Siemens Imaging and syngoDynamics structured reporting Imaging and syngoDynamics structured reporting
Maximum channel, pressures The Mac-Lab Hemodynamic Recording System is part of a comprehensive cath lab workflow infrastructure designed to help make you more efficient. By networking remote The ComboLab system merges hemodynamics and electrophysiology in one powerful, recording system. It combines the full 4 invasive + NIBP 4 4
workstations, the Mac-Lab creates a seamless data management system throughout the cath lab, or any size, and allows near-real-time case review outside the department. A design performance of the CardioLab Electrophysiology Recording System and the Mac-Lab Hemodynamic Recording System in a cost-
utilizing standard protocols enhances the ability to send and receive information from clinical and IT systems effective package that enables dual use of your cardiac cath and EP labs
Maximum channel, ECG Invasive Pressure: 4 channels with means (-25 to 349 mmHg range); Non-invasive Pressure: Automatic and manual modes (oscillometric) Invasive Pressure: 4 channels with means (-25 to 349 mmHg range); Non-invasive Pressure: Automatic and manual modes 12 lead ECG with real time ST values 12 12 surface 96 IECG
(oscillometric)
Plug-in modules ECG: 12-lead with ST segment analysis ECG: 12-lead with ST segment analysis NIBP, SpO2, Cardiac Output, Respiration, ETCO2, FFR/iFR Inputs available in integrated input box include 12-channel surface ECG, 4 pressures, CO, SpO2, NIBP, 2 Inputs available in integrated input box include 12-channel surface ECG, 32, 64, 96 IECG 4
configurable analog outputs, 1 QRS sync output, ETCO2 Capnography pressures, CO, SpO2, NIBP, 2 configurable analog outputs, 1 QRS sync output, ETCO2
Capnography
Display Dual Temp/CO, NIBP, SPO2 (standard), ETCO2 Dual Temp/CO, NIBP, SPO2 (standard), ETCO2, CLab II Plus amplifier (EP) LCD flat panel displays, multiple sizes Control room: 2 x 48.3 cm (19") TFT 1,280 x 1,024 Control Romm 2 x 54.1 cm (21.3") TFT 1,600 x 1,200
Traces Two or three 21" flat-panel, 1,600 x 1,200 resolution Two or three 21" flat-panel, 1,600 x 1,200 resolution Up to 18 User-configurable data parameters including 12-lead ECG, 4 IBP, NIBP, SpO2, respiration, HR, CO User-configurable data parameters including 12-lead ECG, 4 IBP, NIBP, SpO2, respiration, HR, CO
Sweep speeds, mm/s Up to 16 Up to 16 in cardiac cath mode; up to 64/page in EP mode 5, 10, 25, 50, 100, 200, 400 5, 12.5, 25, 50, 100, 150, 200, 400 5, 12.5, 25, 50, 100, 150, 200, 400
Paper speeds, mm/s 5, 10, 25, 50, 100, 200, 400, user-entered value 5, 10, 25, 50, 100, 200, 400, user-entered value 5, 10, 25, 50, 100, 200, 400 N/A N/A
Annotations N/A N/A Yes Yes Yes
Event markers Name, ID, paper speed, ECG and waveform grids, text header, date/time, free drawing Name, ID, paper speed, ECG and waveform grids, text header, date/time, free drawing Yes Yes Yes
Can you reconfigure location of waveforms on screen Yes Yes Yes Yes Yes
Support for electrophysiology Yes Yes Yes, HL7 interface to EP system for data acquisition N/A if hemo only Yes
Number of channels Yes, ComboLab Yes N/A if hemo only 32, 64, 97
Online analysis Upgradeable to 128 with 224 inputs ComboLab IT Up to 128 with 224 inputs N/A N/A N/A
Automated interval measurements Yes Yes N/A No No
Recorder/computer interface Yes Yes Yes Yes Yes
Hemodynamic calculations Yes Yes Yes Yes Yes
Applications Yes Yes Yes Hemodynamic Hemodynamic and EP
Data management Yes Yes Yes Yes Yes
Statistical analysis Yes Yes Yes Yes Yes
Procedural log Yes, via Centricity CardioWorkflow CVIS Yes, via Centricity CardioWorkflow CVIS Custom workflows, prolog custom menus and custom forms Yes Yes
Physician report Yes Yes Default library templates plus user-defined templates syngoDynamics PACS Reporting syngoDynamics PACS Reporting
Statistical reporting Yes, MS Word based Yes, MS Word based Default library of reports plus user-defined queries Yes Yes
How long are each case waveform records stored Yes, via Centricity CardioWorkflow CVIS Yes, via Centricity CardioWorkflow CVIS As long as needed. Site specific settings possible for purge and archiving Until deleted by user Until deleted by user
How many patient cases (entire case waveform records) can Site specific setting, Purge and archive/store options are available. Site specific setting, Purge and archive/store options are available. Tested up to 100,000 Varies Varies
be stored
Networking between labs At least 840 GB for on-line studies at least 41900 Cath Studies or at least 4190 EP Studies At least 840 GB for on-line studies at least 41900 Cath Studies or at least 4190 EP Studies Yes Yes Yes
Network type Yes, with INW Server Yes, with INW Server Ethernet, LAN, WAN DICOM DICOM
Interface with hospital information system (HIS) or 100/1,000 Mbps Base-T Ethernet, TCP/IP 100/1,000 Mbps Base-T Ethernet, TCP/IP Yes, via HL7 interface Yes Yes
cardiovascular information system (CVIS)
Displays X-ray image from angiography system Yes, industry standard HL7 Yes, industry standard HL7 Yes, via Philips IntelliSpace CV No No
Displays live TEE, IVUS ICE or OCT images Optional, GE and third party via DICOM Optional, GE and third party via DICOM Yes, via Philips IntelliSpace CV No No
Can system call up historical images or ECGs from PACS/ Yes Yes Yes, via Philips IntelliSpace CV Yes Yes
CVIS
Frame grabbing No No Yes, via Philips IntelliSpace CV N/A N/A
Zoom Yes, within system application Yes, within system application Yes, via Philips IntelliSpace CV N/A N/A
Other Yes, within system application Yes, within system application Philips Azurion module provides access to Philips Hemo with X3 monitoring functions N/S N/S
Is system built on the same database as CVIS, or does the N/S N/S Requires interface with Philips IntelliSpace CV No No
hemo require an interface to transfer data to the CVIS
Does the system interoperate with EMRs like Epic, Cerner, Interface to transfer data to the CVIS Interface to transfer data to the CVIS Xper IM has the ability to export end of case report to EMR’s Epic, Cerner, etc. It has import interface with Epic Cupid for acquisition of medications, staffing Epic Cupid Epic Cupid
etc. and events into Xper IM documentation menus and for use in physician reporting and data analysis
Can data be exported to external registries? If so, how is data Yes, HL7 file Yes, HL7 file Yes, via HL7 interface Yes, 3rd party interface Yes, 3rd party interface
transferred
Which registries are supported ACC Cath PCI, ICD, STS, IMPACT II, NJ State Registry and Custom Forms for third parties ACC Cath PCI, ICD, STS, IMPACT II, NJ State Registry and Custom Forms for third parties ACC/CATH PCI registries Impact ACC Implact ACC
Templates/reporting for cardiology Yes Yes Yes N/A N/A
Electrophysiology Yes Yes Yes N/A N/A
Interventional radiology Yes Yes Yes N/A N/A
Peripheral vascular Yes Yes Yes N/A N/A
Neurovascular No No Yes N/A N/A
Structural heart Yes Yes Yes, plus interface to PedCath N/A N/A
Does system support pediatric cases Yes Yes Yes Yes Yes
Can users create new cardiac site locations on the fly (during Yes Yes Yes May create new sites for Arterial and Venous but not on the fly May create new sites for Arterial and Venous but not on the fly
procedure) if needed for purpose of uncommon pressure site
documentation
Does the system support multiple hospital locations on a Yes with network connectivity Yes with network connectivity Yes Yes Yes
single database?
FFR integration - acquisition, calculation and documentation Yes Yes Yes, FFR and iFR Yes Yes
FFR integration - automatic attachment of result to relevant Yes Yes No, only manually No No
lesion
FFR integration - integration with the cath physician reporting Yes Yes Yes No No
module
Does system support single button configurations for EDP, Yes Yes Yes Yes Yes
and automatic pullback recordings?
Define amount of storage space for full disclosure procedure At least 840 GB for on-line studies at least 41,900 cath studies or at least 4,190 EP Studies At least 840 GB for on-line studies at least 41,900 cath studies or at least 4,190 EP Studies Up to 200 MB per hour N/A N/A
files
Does the system support finalization of procedure data by Yes Yes Yes Yes Yes
the logged in user?
Can two people chart on the same hemo screen Yes Yes Yes Yes Yes
simultaneously
Is there an automatic indication to identify who charted what Yes Yes Yes No No
records
Can the pre- and post-procedure area notes be charted in the Yes Yes Yes Yes Yes
same hemodynamic report
Where can cath physician complete his report Acquisition or Review WS Acquisition or Review WS Any networked workstation syngoDynamics syngoDynamics
Must the hemo procedure be complete prior to physician No No No No No
starting his report
Does the system support inventory charges management Yes, via Centricity CardioWorkflow CVIS Yes, via Centricity CardioWorkflow CVIS Yes Omnicell and Qsight Omnicell and Qsight
Does the system support procedure charges management Yes, via Centricity CardioWorkflow CVIS Yes, via Centricity CardioWorkflow CVIS Yes HL7 DFT HL7 DFT
Inventory management. If so how (barcode, RFID, manual Yes, via Centricity CardioWorkflow CVIS Yes, via Centricity CardioWorkflow CVIS Barcode including GS-128 codes or integrated to procedure notes N/A N/A
counts, third-party software, etc.)
Other features User-defined macros, valve calcs, shunt calcs, ST Segment, Registry forms. XT and XTi include Cardiotree, Holter Window, CardioImage image capture User-defined macros, valve calcs, shunt calcs, ST Segment, Registry forms. XT and XTi include Cardiotree, Holter Window, CardioImage Integrated Philips iFR/FFR, ST values visualization, Aortic Regurgitation (AR) Index, Hemo control from Touch Screen Module of Interventional X-ray system. N/S N/S
image capture Supports VMware; 24 x 7 remote support. Lifecycle service agreements. XperFlex Cardio, Philips Hemo with FC2010 and Philips Hemo with X3 technology
refresh programs
Website address http://www3.gehealthcare.com/en/products/categories/hemodynamic_recording http://www3.gehealthcare.com/en/products/categories/hemodynamic_recording https://www.usa.philips.com/healthcare/product/HC722463/hemo-with-intellivue-x3 https://www.siemens-healthineers.com/en-us/angio/workplaces/sensis https://www.siemens-healthineers.com/en-us/angio/workplaces/sensis

© 2024 WAINSCOT MEDIA. ALL RIGHTS RESERVED.

You might also like