RU CTX 0720B Web 072920
RU CTX 0720B Web 072920
RU-CTX-0720B
Replaces RU-CTX-0819A and all previous versions
Electric Defrost
3,700 to 32,400 BTUH
2
CENTER MOUNT
Features
Center Mount Unit Coolers are designed for use in walk-in coolers and freezers with very low headroom clearance.
Units mount flush to the ceiling to provide extra storage space. Features include two-way air flow to provide for
even circulation and temperature, easy serviceability, usability with multiple refrigerants, and are available in air and
electric defrost models.
SIZES ELECTRICAL
There are a wide array of sizes available with capacities Available for 115V, and 208/230V. All components are
ranging from 3,700 to 32,400 BTUH at a 10° TD. One factory wired to terminal strips and are UL and cUL
through five fan models are available with air flow listed.
spanning a range of 572 to 3,150 CFM.
AIR DEFROST
HOUSING Air Defrost models (RE6A) are designed for use in
The embossed aluminum casing is lightweight yet coolers down to 35oF.
durable. Each fan section is baffled to prevent short
cycling of the discharge air. The units are designed to
ELECTRIC DEFROST
Electric Defrost 6 FPI models models (RE6E) are
mount flush to the ceiling and are compliant with NSF
designed for use in coolers and freezers down to -10oF
requirements. Top panel contains 3/8” mounting holes
and 4 FPI models (RE4E) are designed for use in freezers
to simplify installation. The housing is sloped to provide
between 32°F to -10°F.
more efficient condensate draining. An uniquely shaped
control access cover allows for easy access for service in
confined spaces. Optional Features
COIL • EcoNet® Enabled Controller1 factory-installed
Copper hairpins consist of high efficiency 3/8” enhanced • EcoNet® Command Center (loose)
copper tubes which are staggered and mechanically • Thermostat - Mechanical or Electric (mounted or
expanded into corrugated aluminum fins achieving loose)
maximum heat transfer while reducing refrigerant • Thermostatic Expansion Valve (mounted or loose)
charge. Die formed fin collars provide even fin spacing.
• Electronic Expansion Valve (mounted or loose)
Medium temperature models are available with 6 fins per
inch (FPI) and low temperature models with 6 and 4 FPI. • Liquid Line Solenoid Valve (mounted or loose)
Sweat connections are standard on all models. • Insulated Drain Pan
• Painted Cabinet (White or Black)
FANS
• Coated Cabinet
Aluminum 12” fans are balanced to provide vibration-
free operation. Improved black plastic fan guard design • Stainless Steel Cabinet
and deep draw venturi achieve optimal air pattern. Fan • Coated Coil (Russproof, Heresite, Bronz-Glow, or
motors and blades can be easily accessed by removing Electrofin®)
the fan guard. • Heat Exchanger (loose)
MOTORS Note
Standard models feature highly efficient Dual Speed
1
EcoNet Control Package includes: EEV; suction pressure
Electronically Commutated (EC) motors. Dual Speed transducer; suction, entering air coil temp. thermistors; local
on-board two-row LCD display and push-button adjustments.
EC motors are available for 115V or 208/230V and are
(Controller replaces TXV, liquid line solenoid valve, room
compliant with California Title 24 regulations. All motors thermostat, defrost termination and fan delay, and time
include thermal overload protection. clock.)
Note
^ 50 Hz available. Contact Factory for additional information.
3
• Unique design of control access cover allows for service in confined spaces
• Ample room in electrical and piping compartments for easy access
4
CENTER MOUNT
EVAPORATOR APPLICATION RATINGS
Multiple conditions combine to determine the application capacity of an evaporator. Walk-in space temperature,
relative humidity, saturated suction temperature difference, and outdoor ambient temperature. All of the factors
are considered when calculating an evaporator application rating. These ratings are considerably higher than the
net capacity value used for DOE ratings (AWEF).
The AWEF of an evaporator is calculated using the dry coil capacity and the daily evaporator power consumption.
Power consumption included fan and defrost power. Evaporator net capacity reported to the DOE database is dry
coil capacity less the full power fan watts. DOE test conditions are at 10°F evaporator/SST temperature difference
and less than 50% relative humidity and 96°F liquid temperature. These conditions create a uniform test method,
but should not be used for equipment selection. The equipment selected would be too large for the application.
Russell’s published application ratings are a guideline for proper equipment selection. They account for true
operating conditions experienced by equipment.
CENTER MOUNT
AWEF Ratings - Electric Defrost Models
Electric Defrost Department of Energy Annual Electric Defrost Department of Energy Annual
Walk-In Energy Factor (AWEF) Ratings Walk-In Energy Factor (AWEF) Ratings
Base Model Defrost Base Model Defrost
FPI AWEF FPI AWEF
Number Type Number Type
Cooler Models1 Freezer Models2
RE6E037DDA Electric Defrost 6 9.00 RE6E037DDA Electric Defrost 6 4.15
RE6E045DDA Electric Defrost 6 9.00 RE6E045DDA Electric Defrost 6 4.15
RE6E075DDA Electric Defrost 6 9.00 RE6E075DDA Electric Defrost 6 4.15
RE6E089DDA Electric Defrost 6 9.00 RE6E089DDA Electric Defrost 6 4.15
RE6E108DDA Electric Defrost 6 9.00 RE6E108DDA Electric Defrost 6 4.15
RE6E125DDA Electric Defrost 6 9.00 RE6E125DDA Electric Defrost 6 4.15
RE6E137DDA Electric Defrost 6 9.00 RE6E137DDA Electric Defrost 6 4.15
RE6E182DDA Electric Defrost 6 9.00 RE6E182DDA Electric Defrost 6 4.15
RE6E221DDA Electric Defrost 6 9.00 RE6E221DDA Electric Defrost 6 4.15
RE6E278DDA Electric Defrost 6 9.00 RE6E278DDA Electric Defrost 6 4.15
1. If the model has a numerical value in the AWEF table, RE4E037DDA Electric Defrost 4 3.95
the following statement applies: “The refrigeration RE4E075DDA Electric Defrost 4 3.98
system is designed and certified for use in walk-in cooler RE4E107DDA Electric Defrost 4 4.01
applications.” RE4E149DDA Electric Defrost 4 4.06
2. If the model has a numerical value in the AWEF table, RE4E186DDA Electric Defrost 4 4.09
the following statement applies: “The refrigeration RE4E234DDA Electric Defrost 4 4.15
system is designed and certified for use in walk-in freezer
applications.”
Distributor lines are 3/16” diameter and 14” long. Distributor connection size is 1/2” for all Air Defrost models.
Distributor lines are 3/16” diameter and 14” long. Distributor connection size is 1/2” for Electric Defrost models with “L”
nozzle and 7/8” for models with “G” nozzle.
* Asterisk represents a variable character based on motor ordered. See page 2 for nomenclature.
– Single feed circuit coils do not get a distributor/nozzle.
^ TXV selections for Air Defrost models are based on +25°F suction temp., 8°F to 12°F evaporator TD. Contact factory for
operating conditions outside of this range.
^ TXV selections for Electic Defrost models are based on -20°F suction temp., 8°F to 12°F evaporator TD. Contact factory for
operating conditions outside of this range.
† SBFDE expansion valves are compatible with R407A, R448A and R449A/B. For other refrigerants, follow manufacturers
selection guidelines.
If unit is not configured with a factory installed TXV, unit will include shipped-loose nozzles sized for 100°F liquid temperature.
8
CENTER MOUNT
Specifications
Refrigerant Approx.
No. of Dimensions (Inches)
Connections Weight (Lbs.)
Model TXV† Hanger
Number Type Liquid Slot
Suction Locations Length Width Height Figure Net Ship
Line1
Applications
9
AIR AIR
27-1/4
Notes:
• Measurements noted on the end view
drawing are the same for all units.
• All mounting holes are 3/8” diameter.
POWER • Mounting holes on four and five fan units
AND are located 20” on center at each tube
3/8
CONTROL sheet.
PANEL SUCTION LIQUID
• All dimensions are in inches.
Side View
3/4 2
6-3/8
6-3/8 11-1/8
6 KNOCKOUTS
(4) SIDE 3/4 X 1/2
(2) TOP NPT DRAIN
27-1/4
POWER
AND
CONTROL 3/8
PANEL SUCTION LIQUID
Side View 2
3/4
6-3/8
6-3/8 11-1/8
6 KNOCKOUTS
(4) SIDE 3/4 X 1/2
(2) TOP NPT DRAIN
10
CENTER MOUNT
Physical Dimensions
Figure 3 - Three Fan
Bottom View
7 19 20 19 7
27-1/4
POWER
AND
CONTROL 3/8
PANEL
SUCTION LIQUID
Side View 2
3/4
NOTE:
MOUNTING HOLES ON 4 FAN AND LARGER ARE
6-3/8
6-3/8 11-1/8
LOCATED 20” ON CENTER AT EACH TUBE SHEET.
6 KNOCKOUTS
(4) SIDE 3/4 X 1/2
(2) TOP NPT DRAIN
7 19 20 20 19 7
27-1/4
POWER
AND 3/8 SUCTION LIQUID
CONTROL
PANEL
Side View
3/4 2
6-3/8
6-3/8 11-1/8
6 KNOCKOUTS
(4) SIDE 3/4 X 1/2
(2) TOP NPT DRAIN
11
27-1/4
POWER
AND 3/8 SUCTION LIQUID
CONTROL
PANEL
Side View
3/4 2
6-3/8
6-3/8 11-1/8
6 KNOCKOUTS
(4) SIDE 3/4 X 1/2
(2) TOP NPT DRAIN
27-1/4
POWER
AND 3/8
CONTROL
PANEL SUCTION LIQUID
Side View
3/4 2
6 KNOCKOUTS
(4) SIDE 3/4 X 1/2
(2) TOP NPT DRAIN
CENTER MOUNT UNIT COOLER
Due to continuing product development, specifications are subject to change without notice.
201 Thomas French Drive, Scottsboro, AL 35769 • PHONE (256) 259-7400 • FAX (256) 259-7478 • russell.htpg.com