0% found this document useful (0 votes)
104 views5 pages

Electromagnetic Flow Meter Catalog - Wesdom

This document describes an electromagnetic flow meter that measures the volume of conductive liquids. It has no moving parts, is highly accurate, and can measure flows between 0.1-15 m/s. It consists of sensors and converters in either an integrated or separated design and is available in sizes from DN3 to DN3000.

Uploaded by

Danyal Nasir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
104 views5 pages

Electromagnetic Flow Meter Catalog - Wesdom

This document describes an electromagnetic flow meter that measures the volume of conductive liquids. It has no moving parts, is highly accurate, and can measure flows between 0.1-15 m/s. It consists of sensors and converters in either an integrated or separated design and is available in sizes from DN3 to DN3000.

Uploaded by

Danyal Nasir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Electromagnetic Flow Meter

DN3-DN3000mm / Flange Connection

Description
Electromagnetic flow meter consists of sensors and converters in two parts. The product is based on Faraday's law of
electromagnetic induction, used to measure the conductance greater than 20 μS / cm volume of conductive liquid flow,
In addition to measuring the general volume of conductive liquid flow, but also can be used to measure strong acid,
alkali and other strong corrosive liquids and mud, pulp, pulp and other liquid-solid two-phase suspension of uniform
volume flow.

Benefit
♦ Medium temperature:
Integral type : -20℃~60℃
Remote type(Rubber&Polyurethane liner): -10℃~80℃
Remote type (PTFE&PFA&F46 liner): -10℃~160℃
♦ Integrated verification,diagnostic function and empty pipe detection.
♦ Measure forward and reverse direction flows.
♦ Built-in reference electrodes,no need to connect ground ring.
♦ Dual frequency excitation and stable zero point.
♦ Precision coil winding technology,makes magnetic field more uniform.
♦ High protection grade,IP65,IP68
♦ No moving parts,no pressure loss.
♦ High accuracy: ±0.5% of reading,±0.3% and ±0.2% optional,velocity >0.3 m/s.

Standard Specification
● Size : DN3-DN3000mm (1/8”~120”) 1.6 MPa (DN200-DN600)
● Accuracy : ±0.5% of reading,±0.3% and 1.0 MPa (DN700-DN1000)
±0.2% optional,velocity >0.3 m/s 0.6 MPa (DN1200-DN3000)
● Conductivity : Normal liquid >20 μS/cm, ● Frequency Output : 1~5000 Hz
Slurry liquid>5 μS/cm ● Language : English,Chinese
● Protection Grade : IP65,IP68 Other languages are available
● Electrode : SS316L, Hastelloy C, Hastelloy B, ● Flange Standard : EN1092-1
Titanium,Tantalum, Platinoiridium PN10,PN16,PN25,PN40
● Power Supply : AC85~250V, DC20V~36V ANSI BS16.5 Class 150,300,600
● Power Consumption :<20W JIS2220 10K,20K,40
● Communication : RS485/Modbus,Hart,Profitbus AS2129 Table D,Table E
● Display : LC Display,128X128mm AS4087 PN16,PN21,PN35
Three lines ● Exciting Current : 125mA, 187mA, 250mA
4 internal push buttons ● Exciting Frequency : 3.12Hz, 4.16Hz, 6.25Hz
● Ambient Temperature:-20℃~60℃ 12.5Hz, 25Hz, 30Hz
● Relative Humidity : 5%~95% ● Material
● Liner Material :Neoprene(Rubber) Measuring Tube : Stainless Steel 304
PTFE Flange : Carbon Steel (standard)
PFA : Stainless Steel 304 (optional)
F46 : Stainless Steel 316 (optional)
Polyurethane ) ● Straight Pipe : Inlet Path ≥ 10D
● Velocity : 0.1 m/s ~ 15 m/s Outlet Path ≥ 5D
● Explosion-proof : Exd IIB T6 Gb ● Signal Output : 4~20 mA,pulse
● Nominal Pressure : 4.0 MPa (DN3-DN150)
Electromagnetic Flow Meter
DN3-DN3000mm / Flange Connection

Dimensions of Sensor and Converter

Nominal External
Weight
Diameter Dimension (mm)

mm L D Kg
3 200 90 4
6 200 90 5
10 200 90 6
15 200 95 8
20 200 105 10
25 200 115 12
Integrated Type
32 200 140 13
40 200 150 14
50 200 165 15
65 200 185 18
80 200 200 20
100 250 235 25
125 250 270 28
150 300 300 30
200 350 340 50
250 450 405 70
300 500 460 95
Separated Type Size
350 550 520 120
400 600 580 140
450 600 640 160
500 600 715 200
600 600 840 280
700 700 895 350
800 800 1015 400
900 900 1115 480 Separated Type
1000 1000 1230 550
1200 1200 1405 660
1400 1400 1630 750
1600 1600 1830 850
1800 1800 2045 980
2000 2000 2265 1200
2200 2200 2475 1600
2400 2400 2685 2000
2600 2600 2905 2400
2800 2800 2905 2700 Separated Type Size
3000 3000 3315 2900
Electromagnetic Flow Meter
DN3-DN3000mm / Flange Connection

Flange Dimension (GB/T9119-2000)

Nominal Caliber D K Φ N C

Pressure (mm) (mm) (mm) (mm) (mm) (mm)


3 90 60 14 4 14
6 90 60 14 4 14
10 90 60 14 4 14
15 95 65 14 4 14
20 105 75 14 4 16
Compact Type Converter
25 115 85 14 4 16
4.0 Mpa 32 140 100 18 4 18
40 150 110 18 4 18
50 165 125 18 4 20
65 185 145 18 8 22
80 200 160 18 8 24
100 235 190 22 8 26
125 270 220 26 8 28
150 300 250 26 8 30
200 340 295 22 12 26
Compact Type Converter Drawing
250 405 355 26 12 28
300 460 410 26 12 32
350 520 470 26 16 35
1.6 MPa 400 580 525 30 16 38
450 640 585 30 20 42
500 715 650 33 20 46
600 840 770 36 20 52
700 895 840 30 24 30
1.0 MPa 800 1015 950 33 24 32
Separated Type Converter
900 1115 1050 33 28 34
1000 1230 1160 36 28 34
1200 1405 1340 33 32 28
1400 1630 1560 36 36 32
1600 1830 1760 36 40 34
1800 2045 1970 39 44 36
0.6 MPa 2000 2265 2180 42 48 38
2200 2475 2390 42 52 42
2400 2685 2600 42 56 44
2600 2905 2810 48 60 46
Seperated Type Convertor Drawing
2800 3115 3020 48 64 48
3000 3315 3220 48 68 50

Note: Following Flange Standards are available.


EN1092-1,PN10 ANSI BS16.5 Class 150 JIS2220 10K AS2129 Table D AS4087 PN16
EN1092-1,PN16 ANSI BS16.5 Class 300 JIS2220 20K AS2129 Table E AS4087 PN21
EN1092-1,PN25 ANSI BS16.5 Class 600 JIS2220 40K AS4087 PN35
EN1092-1,PN40
Electromagnetic Flow Meter
DN3-DN3000mm / Flange Connection

Selection Table electromagnetic flow meter

HTLD

Coil

Electrode

Liner

Main Board
Electromagnetic Flow Meter
DN3-DN3000mm / Flange Connection

Installation Notice

Installed at the lowest point and vertical upward direction Install exhaust valve at the downstreat of flow meter
Don’t install at the highest point and vertical downward diection when drop is more than 5m

Installed at the lowest point when used in open drain pipe Need 10D of upstreat and 5D of downstreat

Dont’ install it at the entrance of pump, install it at the exit of pump Installed at the rising direction

Electrode Property
Applicable in water,sewage and corrosive mediums.
SS316L
Widely used in industries of petrol,chemistry,carbamide,etc
Stainless Steel Covered
Applicable in mediums of no corrosive and low abrasion.
with tangsten carbide
Having strong resistance to hydrochloric acid of any consistance which is below bioling piont.
Hastelloy B Also resistable against vitriol,phosphate,hydrofluoricacid,organic acid etc,which are oxidable
acid,alkali and non-oxidable salt.
Be resistant to oxidable acid such as nitric acid,mixed acid as well as oxidable salt such as
Hastelloy C
Fe+++,Cu++and sea water
Applicable in seawater,and kinds of chloride,hypochlorite salt,oxidable acid(including fuming
nitric acid),organic acid,alkali etc.Not resistant to a pure reducing acid(such as sulphuric
Titanium
acid,hydrochloric acid)corrosion.Acid contains antioxidant(such as Fe+++,Cu++)will greatly
reduce corrosion.
Having strong resistance to corrosive mediums that is similar with glass. Almost applicable in all
Tantalum
chemical mediums.Except for hydrofluoric acid,oleum and alkali.
Platinum-iridium Almost be applicable in all chemical mediums except for aqua fortis,ammonium salt.