BTPLUMBINGA34PRINT

The document contains a waterline layout plate for a 2 bedroom bungalow project. It includes a scale drawing with dimensions and notes for the water connections and piping for the building.

Uploaded by

Albert Oblero
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
58 views7 pages

BTPLUMBINGA34PRINT

The document contains a waterline layout plate for a 2 bedroom bungalow project. It includes a scale drawing with dimensions and notes for the water connections and piping for the building.

Uploaded by

Albert Oblero
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

A B C D E

14750

5275 1758 3443 4275

1976

1976
PATIO
2 MASTER'S
BEDROOM 1" Æ PVC - CWL
WC
1" Æ PVC - CWL

SHO

LAV

T&B
DINING
4300

4300
1" Æ PVC - CWL
LAV 1/2" Æ PVC - CWL

WC

AREA
T&B
W.I.C.
12550

12550
SHO WC LAV

KITCHEN SERVICE
3 AREA
2199

2199
KS

LIVING
4 BEDROOM AREA
2075

2075
5
2000

2000
1/2" Æ PVC - CWL

PORCH CARPORT
6

5275 1758 3443 4275

WM CV
M
GV
14750

FROM WATER MAIN SOURCE


WATERLINE LAYOUT
SCALE : 1:100

SCHOOL / UNIVERSITY: SUBJECT: PLATE TITLE: PLATE NUMBER: RATING:

PANGASINAN STATE UNIVERSITY BT124 BUILDING TECHNOLOGY 4 2 BEDROOM BUNGALOW


DEPARTMENT:

DEPT. OF ARCHITECTURE
STUDENT / STUDENT NO:

OBLERO, ALBERT D. / BS ARCHI 3A


APRIL 29, 2024
MAY 07, 2024
INSTRUCTOR:

AR. MANUEL V MANZANO JR.


FN-02
A B C D E
14750

5275 1758 3443 4275

75 mm Ø PVC-WP

1 CB CB

75 mm Ø PVC-WP

1976

1976
PATIO 75 mm Ø PVC-WP

2 MASTER'S CB

BEDROOM LAV
FD
FD 75 mm Ø PVC-WP

WC

LAV
T&B
DINING
4300

4300
AREA
FD

T&B
WC
W.I.C.
12550

12550
75 mm Ø PVC-WP FD
LAV

KITCHEN SERVICE
3 CB

AREA
2199

2199
KS

LIVING 75 mm Ø PVC-WP

4 BEDROOM AREA CB
2075

2075
75 mm Ø PVC-WP

5 CB CB
2000

2000
PORCH CARPORT
6

5275 1758 3443 4275

14750

TO DRAINAGE
100 mm Ø PVC-SD
TO DRAINAGE
100 mm Ø PVC-SD

STORM DRAINAGE LAYOUT


SCALE : 1:100

SCHOOL / UNIVERSITY: SUBJECT: PLATE TITLE: PLATE NUMBER: RATING:

PANGASINAN STATE UNIVERSITY BT124 BUILDING TECHNOLOGY 4 2 BEDROOM BUNGALOW


DEPARTMENT:

DEPT. OF ARCHITECTURE
STUDENT / STUDENT NO:

OBLERO, ALBERT D. / BS ARCHI 3A


APRIL 29, 2024
MAY 07, 2024
INSTRUCTOR:

AR. MANUEL V MANZANO JR.


FN-02
A B C D E
14750

5275 1758 3443 4275

1976

1976
PATIO
MASTER'S
100 mm Ø PVC-SP

2 CO

BEDROOM LAV
FD
FD

WC

LAV
T&B
4300 DINING

4300
AREA
FD

T&B
WC
W.I.C.
12550

12550
FD
LAV

KITCHEN SERVICE
3 AREA
2199

2199
KS

LIVING
4 BEDROOM AREA
2075

2075
5
2000

2000
PORCH CARPORT
6
DC
5275 1758 3443 4275
LC
14750
TO DISPOSAL

SANITARY LAYOUT
SCALE : 1:100

SCHOOL / UNIVERSITY: SUBJECT: PLATE TITLE: PLATE NUMBER: RATING:

PANGASINAN STATE UNIVERSITY BT124 BUILDING TECHNOLOGY 4 2 BEDROOM BUNGALOW


DEPARTMENT:

DEPT. OF ARCHITECTURE
STUDENT / STUDENT NO:

OBLERO, ALBERT D. / BS ARCHI 3A


APRIL 29, 2024
MAY 07, 2024
INSTRUCTOR:

AR. MANUEL V MANZANO JR.


FN-02
BUILDING CONCRETE WALL 250 75 MMØ P.V.C.
DOWNSPOUT 3000
GENERALNOTES&SPECIFICATIONS:
2000 1000
1 ) _ ALL PLUMBING WORKS TO DONE AND SIZES OF PIPE TO BE USED SHALL BE IN ACCORDANCE WITH THE
NATIONAL PLUMBING CODE OF THE PHILIPPINES AND THE NATIONAL BUILDING CODE .
150 100 150
2 ) _ ANY OTHER WORKS INVOLVED IN PROVIDING THE COMPLETE OPERATION OF THE WATER SUPPLY SYSTEM ,

150
SANITARY AND DRAINAGE SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF ALL CODES AND ORDI-
NANCE OF MUNICIPALITY OF PASIG CITY . GROUT

180
3 ) _ THE PLUMBING CONTRACTOR IS REQUIRED TO REFER TO ARCHITECTURAL , STRUCTURAL , MECHANICAL , AND
ELECTRICAL PLANS AND SPECIFICATIONS , AND SHALL INVESTIGATE ALL POSSIBLE INTEREFERENCES AND INLET BASIN OUTLET
CONDITIONS AFFECTING THE PROJECT .

4 ) _ ALL MATERIALS TO BE USED SHALL CONFORM WITH PHILIPPINE STANDARD AND SHALL BE SUBJECT TO
TEST NECESSARY TO ASCERTAIN THEIR FITNESS IF THE ARCHITECT OR ENGINEER SO REQUIRES .
100 MMØ P.V.C. 100 MMØ P.V.C.

2000
1700
5 ) _ ALL CHANGES IN DIRECTION SHALL BE MADE BY THE APPROPRIATE USED OF FORTYFIVE ( 45° ) WYE OR DRAIN PIPE DRAIN PIPE 4" dia. PVC 4" dia. PVC 4" dia. PVC
INLET PIPE CO 0.50 X 0.50 INLET PIPE CO 40 X 40 DISPOSAL
LONG SWEEP BENDS , EXCEPT SANITARY TEE MAYBE USED ON VERTICAL STACKS AND SHORT QUATER CO
BENDS OR ELBOWS MAYBE USED IN SOIL AND WASTE LINES WHERE THE CHANGE OF DIRECTTION OF FLOW
IF FROM THE HORIZONTAL TO THE VERTICAL AND IN THE DISCHARGE FROM THE WATER CLOSET . 4"X 8"X 16" THICK MANHOLE
C.H.B. WALL MANHOLE

6 ) _ ALL SLOPES FOR HORIZONTAL SANITARY , DRAINAGE BRANCES SHALL MAINTAIN 1 % MINIMUM UNLESS
OTHERWISE SPECIFIED .
CB DETAILED PLAN
7 ) _ ALL PIPES SHALL BE CUT ACCURATELY TO MEASUREMENTS , AND SHALL BE WORKED INTO PLACE WITHOUT
SPRINGING OR FORCING , CHANGES IN THE PIPE SIZES SHALL BE MADE WITH REDUCING FITTINGS .

150
8 ) _ PIPE SHALL BE INSTALLED AS INDICATED IN THE WORKING DRAWINGS ANY RELOCATION OR RENOVATION

50 250 50
REQUIRED FOR PROPER EXECUTION OF OTHER TRACES SHALL BE UPON THE APPROVAL OF THE ARCHITECT
OR ENGINEER .

9 ) _ ALL P V C PIPE DIRECTLY IN CONTACT WITH SOIL MUST BE IN TACT . 0.10 THK. REINF. CONC.
SLAB WITH 10mm dia.
BUILDING CONCRETE WALL BARS @ 0.15 MTS. O.C.
BOTHWAYS

75 MMØ P.V.C. 350 MM x 350 MM x 50 MM PERF. DETAILED PLAN OF SEPTIC TANK


DOWNSPOUT CONCRETE COVER WITH HOLES
1:20
SCALEMTS.
:
STORMDRAIN.
PLUMBINGLEGEND: GRAVEL BED

5050
CB CATCH BASIN

250 100
OPENED END SCREEN 10mm dia. LIFTING OPENED END SCREEN 10mm dia. LIFTING OPENED END SCREEN
CO CLEAN OUT CLEANOUT BARS / HANDLE CLEANOUT BARS / HANDLE CLEANOUT

300 100
COLD WATER LINE 0.50 X 0.50 0.40 X 0.40
MANHOLE MANHOLE
DS DOWNSPOUT 125 THK. REINF. CONC.
SLAB WITH 12mm dia.
DRAIN PIPE LINE GRAVEL BED BARS @ 0.15 MTS. O.C.
BOTHWAYS
FD FLOOR DRAIN INLET 4" dia. PVC
0.30 AIR SPACE
INLET PIPE
OUTLET

300
GV GATE VALVE 12mm dia. VERT. BARS
BASIN @ 0.80 MTS. O.C.
100 MMØ P.V.C.

( VERIFY )
KS KITCHEN SINK
DRAIN PIPE

100
LAV LAVATORY 10mm dia. HOR. BARS
100 MMØ P.V.C. @ EVERY 3 LAYERS

1200
PVC-SP POLYVINYL CHLORIDE SEWER PIPE DRAIN PIPE OF CHB (600mm O.C.)

ST SEPTIC TANK

SEWER LINE
3 - 10mm dia. CONT.
SHO SHOWER BARS
SOIL FILL COMPACTED
SD SHOWER DRAIN

SDP STORM DRAIN PIPE 10mm dia. TEMP. BARS

0.20
@ 0.30 MTS. O.C.

50 250 50
VTR VENT THRU THE ROOF

WC WATER CLOSET
M WATER METER CB DETAILED SECTION
10mm DIA. TEMP. @ 0.30M. O.C.. BARS
0.40
12mm DIA. TEMP. @ 0.30M. O.C.. BARS

CATCH BASIN DETAIL


SCALE :

DETAILED SECTION OF SEPTIC TANK


SCALE :

SCHOOL / UNIVERSITY: SUBJECT: PLATE TITLE: PLATE NUMBER: RATING:

PANGASINAN STATE UNIVERSITY BT124 BUILDING TECHNOLOGY 4 2 BEDROOM BUNGALOW


DEPARTMENT:

DEPT. OF ARCHITECTURE
STUDENT / STUDENT NO:

OBLERO, ALBERT D. / BS ARCHI 3A


APRIL 29, 2024
MAY 07, 2024
INSTRUCTOR:

AR. MANUEL V MANZANO JR.


FN-02
FD

FD
T&B
WC

LA
V

DC
LC LA
V

TO
LA
V
T&B WC FD
10
0m

FD
m
Ø
PV
C-
S
DIS P

KIT
PO CO
SA
L

CH
EN
KS

SANITARY ISOMETRIC LAYOUT


SCALE : 1:100

SCHOOL / UNIVERSITY: SUBJECT: PLATE TITLE: PLATE NUMBER: RATING:

PANGASINAN STATE UNIVERSITY BT124 BUILDING TECHNOLOGY 4 2 BEDROOM BUNGALOW


DEPARTMENT:

DEPT. OF ARCHITECTURE
STUDENT / STUDENT NO:

OBLERO, ALBERT D. / BS ARCHI 3A


APRIL 29, 2024
MAY 07, 2024
INSTRUCTOR:

AR. MANUEL V MANZANO JR.


FN-02
SH
T&B
O
WC

LA
V

L
CW
C-
PV
Æ
1" 1"
Æ
PV
C-
CW
L

LA
V
T&BWC
1"
Æ
PV
C-
CW
L

KIT SH
O

CH
EN 1/2

PV
C-
CW
L

KS

1/2

PV
C-
CW
L

V
M M C
W
GV
E
RC
S OU
AIN
RM
TE
WA
OM
FR

WATERLINE ISOMETRIC LAYOUT


SCALE : 1:100

SCHOOL / UNIVERSITY: SUBJECT: PLATE TITLE: PLATE NUMBER: RATING:

PANGASINAN STATE UNIVERSITY BT124 BUILDING TECHNOLOGY 4 2 BEDROOM BUNGALOW


DEPARTMENT:

DEPT. OF ARCHITECTURE
STUDENT / STUDENT NO:

OBLERO, ALBERT D. / BS ARCHI 3A


APRIL 29, 2024
MAY 07, 2024
INSTRUCTOR:

AR. MANUEL V MANZANO JR.


FN-02
DS

DS

75
DS mm
Ø
PV CB
C-
WP

DS
75
mm
75 Ø
PV
mm C-
Ø WP
PV FD
C- CB
W
CB
P

FD WC
T&B
75 LA
V
mm
Ø DS
PV
C-
W P
CB

75
DS mm
Ø
PV
C-
LA WP
V

T&B
LA
V FD
DS WC

10 TO FD
0 mDR CB
m AIN
Ø AG
PV E
C-
SD KIT 75
mm

C
Ø
PV
C-

HE WP

N
CB KS

75
CB mm
Ø
PV
C-
WP

10TO
0 mDR
m AINA
Ø G
PV E
C-
S D

STORM DRAINAGE ISOMETRIC LAYOUT


SCALE : 1:100

SCHOOL / UNIVERSITY: SUBJECT: PLATE TITLE: PLATE NUMBER: RATING:

PANGASINAN STATE UNIVERSITY BT124 BUILDING TECHNOLOGY 4 2 BEDROOM BUNGALOW


DEPARTMENT:

DEPT. OF ARCHITECTURE
STUDENT / STUDENT NO:

OBLERO, ALBERT D. / BS ARCHI 3A


APRIL 29, 2024
MAY 07, 2024
INSTRUCTOR:

AR. MANUEL V MANZANO JR.


FN-02

You might also like