EE2006D Assignment 4
EE2006D Assignment 4
Write your Serial no., Roll no. and Name on the answer sheet.
1. If a 500kVA single-phase transformer has an efficiency of 95% both at full load and 60% full
load at upf, determine its efficiency at 75% full load at a power factor of 0.8 lagging.
2. A 20kVA, 2500/250V, 50Hz, single phase transformer gave the following data on test. OC test
(low voltage side): 250V, 1.4A & 105W and SC test (high voltage side): 104V, 8A & 320W. Draw
the equivalent circuit of the transformer referred to low voltage side and insert the parameter
values.
3. A 10kVA, 500/250V, 50Hz, single phase transformer gave the following data on test. OC test
(low voltage side): 250V, 3A & 200W and SC test (low voltage side): 15V, 30A & 300W. Calculate
its full load voltage regulation and efficiency at a power factor of 0.8 lagging.
4. Two 100kVA, single phase transformers are connected in parallel on both primary and secondary
sides. One transformer has an ohmic drop of 0.5% and a reactive drop of 8% of the voltage on
full load. The other has corresponding drops of 0.75% and 4% respectively. How will the following
total loads be shared? (a) 180kW at 0.9 lagging power factor, (b) 120kW at 0.6 lagging power
5. Two single phase transformers A and B are connected in parallel to supply a load having a
resistance of 5 and an inductive reactance of 2. The equivalent resistance and reactance of
transformer A referred to the secondary winding are 0.25 and 1.5 and that of transformer B
are 0.3 and 2 respectively. The open circuit secondary voltages of A and B are in the ratio
100:98. Calculate the inductive reactance to be connected in series with the secondary of
transformer B to have the magnitudes of the currents delivered by A and B in the ratio 1.8:1.
6. Prepare short notes on the following with neat sketches wherever necessary:
Page 1 of 1