Ground Floor Power and Lighting Layout
Ground Floor Power and Lighting Layout
1 1
PLANTERS
ROOF LINE
PLANTERS ACU
- All Electrical works shall be done in accordance with the latest edition of the Philippine Electrical
2 2
3 b b 3 CKT
Code (PEC), the rules and regulations of the Local Enforcing Authority, the National Building Code,
and the requirements of the Local Power Company or Utility
10
4 4
a
DN DN
ACU
- Other Codes, standards governing the specific designs shall served as a guide or basis on the
b b
WP CKT
actual implementation and execution of Electrical works
BEDROOM 4 9 BEDROOM 4
Sa a
RANGE - All Electrical works shall be under the direct supervision of either of the following with valid license:
b range b range
CKT Professional Electrical Engineer
12
Registered Electrical Engineer
BEDROOM 3 BEDROOM 3
Registered Master Electrician
a b
closet closet
sink sink
b
CKT
- Electrical Supply shall be as required for specific use whether:
ROOF LINE
ROOF LINE
2 Sab
KITCHEN island DINNING fd KITCHEN island DINNING fd 220 V Single Phase 2 - Wire 60 Hz system
a Sab Sa
a 110 / 220 V Single Phase 3 - Wire 60 Hz system
T&B T&B
a a
b Sa
b
closet
lav.
wc closet
lav.
wc
- All wires and cables to be used shall be copper, insulation required will depend on its specific use to wit:
sho. sho.
Lightings - THHN Type
Sa
CKT CKT
b b
6 11 Convenience outlets - THHN Type
ref ref
Sab REF
Power (ACU's, Motors, Heaters, etc)- THHN Type
Service Entrance - THHN Type
b b PLANTERS PLANTERS Service Lateral - THHN Type
a
c
Service Service Drop - THW Type
Sabc b b CKT
Sa
MPB 4 MPB
- The minimum size of wire and conduit to be used shall be:
BEDROOM 2 BEDROOM 2
a
lav. lav. Lightings - 2.0 mm2, 15 mm dia. Pipe
CKT Sabc
1
b
ACU
C.O. - 3.5 mm2, 15 mm dia. Pipe
wc a b wc
T&B T&B
closet
closet
CKT
CKT
7
8
- Type of wiring shall be in rigid PVC pipe in concrete slab and floor as required.
closet
closet
LIVING ROOM LIVING ROOM
b b
sho.
fd
a ACU
sho.
fd
- Panel boards shall be located on load center to minimize length of home runs
a
BEDROOM 1 BEDROOM 1 - All circuit breakers shall be Inverse Time Type, and of required Interrupting Capacity Rating as designed,and
b
of Residential Type Category
- Grounding system shall be implemented as required. All metal parts of all equipment shall be bonded and
c
grounded in accordance with Article 2.50 of the PEC. Ground resistance shall be tested and should passed
CKT
WP 5
2 PLANTERS 2 PLANTERS
Motor loads in general, if any
a
1 1
Note: Results shall passed the required insulation value in MEGA OHMS
UP UP - Installation of Standby Generator shall be accompanied with Transfer Switches to supply power in case of
blackouts is [Link] in case, its rating in kVA shall be based on the emergency power requirement of the
ROOF LINE
b b installations or as required. Shifting of power shall be done manually or automatic or as required.
- Scheduled (post) electrical inspection and testing is highly recommended.
- Breakers shall be bolt-on Type
1 GROUND FLOOR LIGHTING LAYOUT 2 GROUND FLOOR POWER LAYOUT 3 ELECTRICAL NOTES
E1 SCALE 1:1OO Mts. E1 SCALE 1:1OO Mts. E 1
ARCHITECT PROFESSIONAL ELECTRICAL ENGINEER PROJECT TITLE & LOCATION APPROVED BY: DATE REVISION SHEET CONTENTS SHEET NO.