0% found this document useful (0 votes)
112 views

Timer Manual

This document describes an electronic time delay relay module with 18 programmable modes. It has features like reverse protection and auto power saving. The module can be used to control systems and has different timing functions like on delay, interval, repeat cycles, and retriggerable modes.

Uploaded by

Žymantas Dapkus
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
112 views

Timer Manual

This document describes an electronic time delay relay module with 18 programmable modes. It has features like reverse protection and auto power saving. The module can be used to control systems and has different timing functions like on delay, interval, repeat cycles, and retriggerable modes.

Uploaded by

Žymantas Dapkus
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

UCTRONICS DC 12V Programmable Multifunction Time Delay Relay Module

Function 7. Limited Repeat Cycle-Starting Open 8. Limited Repeat Cycle-Starting Close


Model: U6030

1. Introduction
This programmable multifunction time delay relay module is designed for different kinds of control systems. It has
18 preset modes, users can program one of the mode and its parameters to fit for their applications. The four keys
CH1 CH1
are used for programming the relay module, the four segment LED display are used for displaying the mode and Timing
timing information. Chart t1 t2 t1 t2 t1 t2 t1 t2
NO NO

2. Features T T

 Programmable 18 delay modes, to meet the switch control of all kinds of occasions
 Reverse protection, avoid burning down the module as connecting the wrong terminals
*
 Auto power saving function, user could set up on their own Function 9. Self-locking Relay 10. Retriggerable Delay Off
 All options setting could be saved automatically, the content will not be lost even power down

3. Functions

Function 1. On Delay 2. Interval CH1 CH1


Timing
Chart t1
NO NO

T T
CH1 CH1
Timing
Chart t1 t1 t1 t1
NO NO

T T Function 11. Retriggerable One Shot: Starting Open 12. Retriggerable One Shot: Starting Close

Function 3. On delay and Interval 4. Interval and On delay

CH1 CH1
Timing

CH1 CH1 Chart t1 t1


Timing NO NO

Chart t1 t2 t1 t2 t1 t2 t1 t2 T T
NO NO

T T

Function 13. Retriggerable Timing: Starting Open-Close 14. Retriggerable Timing: Starting Close-Open
Function 5. Repeat Cycle: Starting Open 6. Repeat Cycle: Starting Close

CH1 CH1
CH1 CH1 Timing
Timing
Chart t1 t2 t1 t2 t1 t2 t1 t2 t1 t2 t1 t2
Chart t1 t2 t1 t2
NO NO
NO NO
T T
T T
Function 15. Unlimited Repeat Cycle 1 16. Unlimited Repeat Cycle 2

CH1 CH1
Timing
Chart t1 t2 t1 t2 t1 t2 t1 t2
NO NO

T T

Function 17. Limited Repeat Cycle 1 18. Limited Repeat Cycle 2 5. Keys functions
Actual mode Key Operation Function
Long press Enter Working mode
SET
Short press Select setting item
CH1 CH1 Long press Reveal/Cancel decimal point
Timing Setting mode SWI Move cursor among 4 segment LEDs
Short press
Chart t1 t2 t1 t2 display
NO NO
NUM+ Short press Number +
T T
NUM- Short press Number -
Long press Enter Setting mode
SET
Short press Entry/Exit Energy Saving mode
* Remark: for this function, if T1 is 0 second, when applying the power supply the output switches to operate condition, SWI
Working mode
if no signal the output switches to release condition.
NUM+ Invalid
NUM-
4. Wiring Diagram
For more detailed information, please download in the link following which includes the Operation Manual:
Module Voltage/Signal Input Module Output https://www.uctronics.com/download/Amazon/U6030.pdf
Normally open contact, disconnected to COM terminal in
6. Specification
DC+ DC 12V positive terminal NO normal state, connected to COM terminal when relay is
pulled in Module Size 57*30*18.5mm

DC- DC 12V negative terminal COM Common contact Operating Voltage: 12V Load Voltage:NC:DC 30V or AC 250V / NO:DC 28V or AC 125V
Normally closed contact, connected to COM terminal in
Static Current:5.5mA Load Current:10A
CH1 Input signal terminal NC normal state, disconnected to COM terminal when relay is
pulled in Delay Method: Delay when power on Max. Frequency: ≤5KHz

7. Quick Start Guide


Function 1 Delay on to turn on a light after timing 5s. See wiring diagram in Article 4.
 Long press SET to enter Setting mode; (at this moment the segment LED display starts to flash at the far right)
 Short press SET to select parameters of MD; (at this moment the LED near MD turn on constantly)
 Short press NUM+/NUM-, enter 0005, the value of segment LED display, that means 5s. Short press SWI to
move cursor among 4 segment LED displays;
 Long press SET to quit Setting mode and enter Working mode.