Oil control guns, manufactured in aluminium, with ergonomic grip and trigger to reduce operator High pressure grease control guns with ergonomic
hand fatigue. NBR valve with progressive action, for comfortable operation when dispensing body and trigger designed to reduce operator
products, even with high ratio (10:1) oil pumps. All guns include a ball bearing inlet swivel with hand fatigue. Manufactured in aluminium with
large capacity screen filter. steel high pressure section.
Maximum working pressure: 105 bar (1,500 psi). Maximum working pressure: 500 bar (7,150 psi).
Maximum delivery: 25 l/min (6.6 US gpm). Inlet thread: 1/4" BSP (F).
Fluid inlet thread: 1/2" NPSM (F). Outlet thread: 1/8" BSP (F).
Guns available with a variety of outlets to fit every application.
413 077 Grease control gun
Models
Grease control gun with rigid outlet with 3 jaw
connector (PN 121 050).
Outlet type Non drip nozzle
Part No. Application included included 413 080 Grease control gun with z-swivel
Grease control gun with z-swivel (PN 414 300),
363 082 - None None
rigid outlet and 3 jaw connector (PN 741 300).
363 075 GEAR OIL 110º rigid swiveling (369 217) Manual 413 081 Grease control gun
Grease control gun with 450 mm double steel
363 077 ATF , LUBRICANTS Straight flexible (369 200) Manual braid reinforced rubber hose (PN 140 050) with
3 jaw connector (PN 121 050).
ALL TYPES OF Flexible with 90º outlet,
363 078 Semi automatic
LUBRICANTS swiveling (369 218) 413 082 Grease control gun with z-swivel
Grease control gun with z-swivel (PN 414 300)
363 079 MOTOR OIL 60º rigid (369 215) Semi automatic
and 450 mm double steel braid reinforced
rubber hose (PN 140 050) with 3 jaw connector
(PN 121 050).
High delivery oil control gun fluid control gun Oil bar
363 041 High delivery oil control gun 186 300 Fluid control gun 361 200 Oil bar
High delivery oil gun manufactured in steel. Control gun with reinforced polyamide body Oil dispensing bar for up to four products.
With lockable trigger and guard to prevent and stainless steel valve mechanism for use with Delivered with one outlet, up to 3 additional
accidental opening of the valve. Delivered with fluids like windshield washer, glycol solution outlets can be mounted.
inlet swivel, and rigid outlet with semiautomatic (anti-freeze) and other water based fluids.
non-drip nozzle. Includes brass inlet swivel and flexible outlet 361 110 Additional outlet valve for oil bars
Maximum working pressure 100 bar. with 90º angled outlet.
Fluid inlet thread 3/4" NPT (F). Maximum working pressure: 40 bar (570 psi). 366 550 In-line meter kit for oil bars
Maximum flow: 15 l/min (4 US gpm). An in-line meter can be mounted as an option.
Inlet thread 1/2" BSP (F).
Oval gear meter with mechanical odometer Oval gear meter with electronic digital LCD display 366 750 coupled to a durable but lightweight
style register, for use with lubricants up to oil control gun that incorporates a rugged ball bearing swivel with inlet screen filter. Meter is
SAE 140. Resettable partial reading up to 999,9 supplied with a protective rubber shroud.
litres and non-resettable totalizer. Meters are Meters are factory calibrated. Also they, can easily be re-calibrated in the field for increased accuracy.
factory calibrated for maximum accuracy and Meter can measure in litres , quarts, pints and US gallons.
include protective rubber shroud. Maximum working pressure: 70 bar (1,000 psi).
The meter is flange coupled to a durable but Oil flow range: 1 to 25 l/min (0.25 to 7 US gpm).
light weight oil control gun that incorporates a Fluid inlet thread: 1/2' BSP (F).
rugged ball bearing inlet swivel with filter.
Maximum working pressure: 70 bar (1,000 psi). Models
Oil flow range: 1 to 27 l.p.m. (0.26 to 7.1 US gpm).
Fluid inlet thread: 1/2" BSP (F). Part No. Application Outlet type
365 710
411 100 oval gear In line grease meter with electronic digital display
366 750 - 836 504 OVAL GEAR in line oil METER WITH electronic DIGITAL DISPLAY
Accessory:
836 504: Protective rubber shroud for meter 366750.
366 850 oval gear in line OIL METER WITH MECHANICAL DISPLAY
Oval gear meter with mechanical odometer style register for use with lubricants up to SAE 140.
Resettable partial reading up to 999.9 litres and non-resettable totalizer. Meters are factory calibrated
for maximum accuracy and include protective rubber shroud.
Maximum working pressure: 70 bar (1,000 psi). Oil flow range: 1 to 27 lpm (0.26 to 7.1 US gpm).
Fluid inlet and outlet threads: 1/2" BSP (F). Includes protective rubber shroud. Accuracy: ±1%
366 850 Oval gear in-line meter
With mechanical register in litres.
366 725 - 366 726 High flow in line meters with electronic digital display
Oval gear in line meters with electronic digital LCD display. The meter has two separate displays: a
resettable 4 digit batch display and a 6 digit permanent totalizer. Meters are factory calibrated and
they can easily be re-calibrated in the field for increased accuracy. Meters can measure in litres,
quarts, pints or gallons. Meters are compatible with lubricants up to SAE 240, diesel and glycol
solutions.
Equipped with ball bearings for easy articulation even at high pressure. For best results, use a
straight swivel between the pump and distribution hose and Z swivel between the hose and grease
control gun. Maximum working pressure: 500 bar (7,150 psi).
140 050 Double steel braid reinforced grease hose, 450 mm.
369 215
Swivels
736 601 1/2" BSP (F) oil inlet swivel. For use with standard hose end meters
736 601
836 404 Oil filter. To be placed between a hose and 1/2" swivel
3 4
2 1
F
(PN 381 001 + PN 381 600) luid Management in today’s shops poses several challenges. As the size of the shop increases,
properly dispensing and controlling fluids challenges older system and equipment. Additionally,
2 AMS Accesess Key pad the increased cost of today’s lubricants and the popularity of synthetic lubricants place a higher
(PN 381 001) demand for the proper accounting of lubricants usage. Samoa is proud to lead the industry with
our proven offering of inventory and fluid dispense management products. From the simplest entry
3 intelligent flow control unit level console to sophisticated computerized management system, we can supply the equipment
(PN 381 500) required for the professional management of both new and used fluids.
The Advanced Monitoring System (AMS), the software at the heart of our state-of-the-art fluid and
4 intelligent fluid dispense manager inventory management system, has been installed in several thousand facilities around the world.
(PN 381 550) Based on our experience in the design of systems for fluid monitoring and the management of
workshop activities, we have brought true innovation to an old concept. We have created a system
5 FLUID CONTROL UNIT designed to improve profitability through controlled fluid distribution work-order accountability.
(PN 380 550) The system’s ease of integration allows you to design any size of installation using a minimum
number of components, adaptable from a single-point dispense system to the largest system
6 Network protocol converter including more than 100 fluid outlets. This modularity also allows the integration of complementary
(PN 381 300) functions, such as remote displays, stock level detectors, volumetric measuring probes, control
access points and the automatic scheduling of any “on/off" function and guarantees the possibility
7 tank inventory system of future evolution should new needs arise.
(PN 382 100) The network topology utilized by the AMS is the CANBUS network, which was originally developed
to manage all the functions of an automobile through one single cable. This technology gives the
system a unique simplicity of installation, whilst offering the highest reliability, accuracy and speed
of communications. CANBUS networks are used throughout industry, whenever a highly reliable
network is required.
Directly connected to the mains electricity supply (115 / 230 V AC) the AMS keypad has an internal
24 V DC power supply that provides the electrical power for 1 to 8 outlets, depending on the
distance. The number of AMS keypads in a system depends on the layout of the workshop and
it is not limited. The AMS can manage up to 100 outlets, each equipped with an Intelligent Flow
Control Unit.
The entire system can be controlled through a PC using a PC interface and communications adapter
together with special software. It also allows communication with the workshop Data Management
System using an additional software module.
The AMS system can also integrate the Advanced Tank Management System. This allows an
accurate control of oil inventory and the automatic updating of inventories whenever lubricants are
delivered. It also allows a pump to be stopped whenever the oil inside the tank is below a critical
level, so eliminating the possibility of air getting into the fluid distribution system.
381 501 - 381 953 381 600 - 381 905 - 381 001
381 501 Intelligent Flow Control Unit with 381 013 AMS Access keypad with ticket printer (Voltage input: 12 V DC)
CAN controller 100 PPL
Connection threads: 1/2" BSP (F). 381 000 AMS Access keypad without ticket printer (Voltage input: 115 - 230 V AC)
381 500 Intelligent Flow Control Unit with 381 600 Application software memory module
CAN controller 100 PPL and installation To be inserted into its slot in the access keypad, includes the system operating software. One
accessories memory module must be used with every system.
Includes electrical connectors and two 90º
fittings for connection to the fluid distribution 381 905 Five coded keys set
line. Connection threads: 1/2" BSP (F).
381 904 External RS-422/RS-232 Converter 381 102 Additional power supply box
Each access keypad has a power supply box that
381 200 Thermal ticket printer Ticket printer for installation inside the access keypad. provides energy to the system for opening and
closing up to eight solenoid valves. An additional
381 950 Cable for CAN bus Comunications cable to connect system elements, adequate in most power net box is required when one single keypad
installations. needs to control more than eight hose reels or if the
distance between the keypad and the last IFCU is
736 353 Wall bracket for 381 000 or 381 001 Keypads for wall mounted applications. too far.
381 912 IFCU bracket for open reels (501 and 504 series) for wall mounted applications.
736 349 Bracket for mounting up to 6 IFCUs (381 500) on top of a six hose reel stand.
Requires brackets 381 911 and 381 910 and cover 736 377.
381 910 IFDM or remote display (RDU) bracket. Use together with 736 349.
736 377 Cover It covers the open area of bracket 381 911 when no IFCU is installed.
Reraessi. Dolobore volorpe rcilit lut luptat wis ad magniam dolore miniam do con elit utem dolortis
dolorerit ver sed dolutem vullandrem adigna am esenit velisim iliquat at velent augiam dolore
faciliquis nostrud te magnim ea core magna feugait
1 wisit aute commolo rerosto ent lor sum exercil
1 1
lutat, quipisim vel irillandio consecte min eum diat, sum euisi
3 3
2 2 2
4 Network protocol converter NTPC Modular fluid monitoring and security system for small to medium size applications. It can be used
to cover applications from a single access point keypad control system through to a multi-dispense
382 110 point, multi-access, PC linked system.
SYSTEM COMPONENTS
382 110 Beta Key pad BCM-R
Alphanumerical keypad to be mounted in the workshop allowing technician remote access to
outlets / reels using numerical ID authorisation. It also allows.
382 112 Multi fluid Dispense Manager with 4 digits display MFDM-LD
Provides control to up to 6 outlets and communication between different keypads. Several Input
/ Output Control Units can be used in a system whenever there are more than six outlets in the
system. Includes power supply unit. Voltage input: 115 - 230 V.
381 300 Network protocol converter and software (NTPC-RS232)
The network protocol converter allows reliable communication with a PC, through a RS232 serial
382 112 port connector.
The PC software delivered with the NTPC is user-friendly and it takes full advantage of the flexibility
and the wide possibilities of the fluid monitoring System. This software supports both daily
operations and statistical analysis, to help develop sales and increase profit. The software runs on a
PC, in a WINDOWS environment and uses an ACCESS database.
381 350 Network protocol converter and software (NTPC-USB).
Same as 381 300 with USB connection.
382 116 Beta Validation Chip and PC Software for RS232 connection to Beta Keypad
A Beta validation Chip can be placed into the Beta Keypad in order to connect it directly to PC
(through RS232 port).
PULSE METERs*
600 281 In line pulse meter
600 600 In line pulse meter for wind shield wash and antifreeze
380 550
Solenoid valve*
389 001 Solenoid valve
2 Solenoid valve (max. 10) Reraessi. Dolobore volorpe rcilit lut luptat wis ad magniam dolore miniam do con elit utem dolortis
dolorerit ver sed dolutem vullandrem adigna am esenit velisim iliquat at velent augiam dolore
3 Key pad module faciliquis nostrud
2 te magnim ea 2 core magna feugait wisit
2 aute commolo2 rerosto ent lor sum exercil
lutat, quipisim vel irillandio consecte min eum diat, sum euisi
1 1
T
his powerful console is designed for shops that want simple control of their fluids. IMC offers
ease of operation, great value and several features not previously available in entry level Fluid
Management and Control System.
IMC works with one pulse meter at each pump (maximum two pulse meters) and a solenoid valve
at each fluid outlet (maximum 10 solenoid valves in total). The system does not allow simultaneous
operation outlets with the same fluid; however different fluids can be dispensed simultaneously.
An upgraded Inventory Management Console, which allows connection to a PC, is available.
PC connection makes setting and maintaining the system parameters easier and it is a powerful
inventory control tool that allows tank level monitoring to alert the oil vendor or the shop purchase
department with an email when the oil inventory level is low.
IMC standard features and capabilities are:
• Controls one or two fluids and up to 10 dispense points. Manages simultaneous dispensing of two
different fluids.
• Up to 200 users, system access through pin number or coded key.
• Allows control of one air valve, so air supply is only available during service operating hours.
• Inventory management on a declining balance: allows initial inventory to be entered and deducts
for each dispense. Manager needs to enter each delivery and the console alerts when inventory
level is low.
• Two operation levels, user and manager levels. At user level it is only possible to order a dispense.
At manager level is possible to adjust inventory levels, set inventory warning levels and perform
other management functions.
• The system requires 115 to 230 V AC mains power.
• Can work with metric or US units of measure.
Iquipcomponents
Imc modit iriuscidunt nos niam ver ip 000 000 381 002
600 281 In line pulse meter 600 600 In line pulse meter for windshield 389 001 Solenoid valve
Line meter with 328 pulses per litre pulse washer and antifreeze 24 V DC solenoid valve for oil, glycol and wind
transmitter output. For connection to each Line meter with 328 pulses per litre pulse screen washing fluids.
pump outlet or to the Advanced Monitoring transmitter output. For connection to each pump Inlet - Outlet: 1/2" BSP (F). Maximum working
System when using the Intelligent Fluid outlet or to the Advanced Monitoring System pressure: 50 Bar (715 psi).
Dispenser Manager (PN 381 550). Meter does when using the Intelligent Fluid Dispense
not have display or function buttons. Equipped Manager (PN 381 550). Meter does not have
with connection terminal and reel open display or function buttons.
indication light. For use with lubricants. Manufactured in stainless steel with Viton seals.
Equipped with connection terminal and inlet
Inlet-Outlet: 1/2" BSP (M) with 60º cone seal. strainer. For use with windscreen wash fluids,
Minimum flow: 1,5 l/min (0.4 US gpm). detergents and antifreeze mixed with water.
Maximum flow: 15 l/min (4 US gpm). Inlet-Outlet: 1/2" BSP (M) with 60º cone seal.
Maximum working pressure: 50 bar (715 psi). Minimum flow: 1,5 l/min (0.4 US gpm).
Maximum flow: 30 l/min (8 US gpm).
Maximum working pressure: 150 bar (2,150 psi).
Protects the pump from running dry and the waste oil tanks from overflowing. The module can
accept up to four tank level sensors, e.g. three low level sensors in fresh oil tanks and one high level
sensor in a waste oil storage tank. The unit includes four indicator LEDs and an acoustic alarm signal
that give a warning when each of the tanks reaches a critical level. 230 V – 50 Hz AC.
When the Tank Alert System is connected to an Advanced Monitoring System, AMS, it provides
signals to warn of a high level in the waste oil tank (to prevent overflow) and to warn of low levels
in the new oil tank, making possible to automatically close a solenoid valve in the pump air supply
(to prevent air entering the fluid lines and to stop the pumps running dry).
Control module for monitoring the volume in up to four tanks using barometric level sensors. The
level sensors provide accurate measurement of the volume in each tank and it is possible to set
critical control threshold levels that define when the Tank Management System should stop the air
supply to each pump (using a solenoid valve PN 389 001). The system can work as a stand-alone
unit or as part of an Advanced Monitoring System AMS.
When used as a stand-alone unit, the system is set up using an access keypad (PN 382 110). This
keypad is used to set up tank parameters and the threshold levels and the actions required from
the system, such as closing a solenoid valve that controls the air supply to a pump. Optionally, the
system can be controlled and set up through a PC using a software pack that includes a validation
chip that must be installed inside the access keypad.
When used with an AMS system, the Tank Management System is connected directly to any keypad
in the system (AMM version 3.1.3 or higher) and it transmits accurate real time information about
the inventory in the oil tanks, increasing system security, and reliability of the oil inventories. This
way manual inventory adjustments are no longer required, for example when new oil is supplied
into a tank. When the AMS is running connected to a PC, using AMS-WIN PC version 2.1 or higher,
the tank inventory system is controlled and set up through the AMS software.
382 120
382 100 Tank Management System module