R
ASSEMBLY INSTRUCTION
NE8MC6 | etherCON Cable Connector CAT 6
®
A A Slide the boot onto the cable.
B Terminate the RJ45 connector.
See following pages.
C Press the locking latch of the RJ45 and place the
two brackets onto the RJ45.
Pay attention:
Hold the brackets together.
B
D Put chuck onto the cable.
Pay attention:
Look out for the guiding key.
E Slide RJ45 and chuck together into the Neutrik
C NE8MC6 housing.
Pay attention:
The RJ45 latch has to be on the opposite side
of the key.
F CAUTION:
max. 0.7 mm
D
E Key
F
max. 0.7 mm
BDA 194 Page 1
R
ASSEMBLY INSTRUCTION I etherCON® CAT 6
G G Finish the assembly by turning the bushing onto
the connector. Screw the bushing fully up to the
end.
Suitable cables:
AWG 22 to 28 soldid or stranded conductors with an
insulation. O.D. 0.037” / 0.95 mm to 0.047” / 1.07 mm.
Jacket: O.D. 0.22” / 5.5 mm to 0.25” / 6.5 mm
FINISHED etherCON NE8MC6: ®
Find more etherCON ®
details on
www.neutrik.com.
Neutrik AG LI T: +423 / 237 24 24 F: +423 / 232 53 93 Neutrik France FR T: +33 1 / 4131 6750 F: +33 1 / 4131 0511
Neutrik USA Inc. USA T: +1 704 / 972 3050 F: +1 704 / 438 9202 Neutrik Tokyo Ltd. JP T: +81 3 / 3663 4733 F: +81 3 / 3663 4796
Neutrik (UK) Ltd. UK T: +44 1983 / 811 441 F: +44 1983 / 811 439 Neutrik Hong Kong Ltd. HK T: +852 / 2687 6055 F: +852 / 2687 6052
Neutrik Vertriebs GmbH DE / NL / AT/DK T: +49 8131 / 280 890 F: +49 8131 / 280 830
Draft. Nr.: BDA 194 V2 I Update: 2021-07-20 I Data subject to change without prior notice. © 2021 NEUTRIK®. NEUTRIK® are registered trademark of Neutrik AG. ALL RIGHTS RESERVED.
www.neutrik.com Page 2
B Terminate RJ45 connector on the cable.
Consider the cable end termination either according to the TIA 568A or T568B standard.
Connection
RJ 45 Color code
PIN No. T568A T568B
1 W-G W-O
2 G O
3 W-O W-G
4 BL BL
5 W - BL W - BL
6 O G
7 W - BR W - BR
87654321 8 BR BR
1 Assembly of wire, load bar and plug.
2 Strip outer jacket 20 mm long.
3 Separate pairs in bundles.
4 Straighten and separate into individual leads.
5 Organize leads into proper order and trim edge to be
even.
6 Wire lead ends shown organized and trimmed.
BDA 194 I 17.12.2018 -3-
R
ASSEMBLY INSTRUCTION I etherCON® CAT 6
7 Insert the load bar and the wires into the open end.
8 Slide load bar into position against jacket.
9 Trim leads so jacket is 8.64 mm / 0.34” from edge.
8.64 mm
[0.34”]
10 Insert wires and load bar into plug and push fully
forward.
Terminate plug with hand terminator MOLEX #62202-
0500 or any other suitable crimp tool.
11
In the case of using shielded cable crimp shield to
connector.
BDA 194 I 17.12.2018 -4-