Module Schematic
Module Schematic
507 - 160V
508 +160V
503 - 16V
511 - 12V
502 +16V
510 +12V
501 COM
514 VBC
517 VAC
515 VCB
516 VCA
512 VAB
513 VBA
519 IA + 2 SHT
520 IA - 2
SHT 3
3
3
6
6
3
3
2
2
3
3
3
3
3
3
521 IB + 2
SHT
522 IB - 2
523 IC + 2
524 IC - 2
525 I TOTAL 2
526 TACH 2
AC REGULATOR
BOARD 527 0V 2
R R228 & R328 WERE 47K CHANGED TO 7/6/75 EMD 16 CYL – NO TACH 528 CB TRIP C 4
SELECT. ADDED D170 (ON SHT 4). K2 529 CB TRIP NO 4
ADDED D169 & R76 ON SHT 8.
530 CB TRIP NC 4
Q ADD SHT 8 (PULSE PICKUP TACH 4/23/75 531 REV PWR C 4
CIRCUIT) K1
532 REV PWR NO 4
P R7 WAS 100K, R8 WAS SEL, R10 WAS 12/17/74 533 THROTTLE + 5
88K, R13 WAS 100K, R52 WAS 22K, R61
534 KW LMT 2
SHT
SHT
WAS 100K, R82 WAS SEL, R80 WAS
100K, R84 WAS 100K, R85 WAS 22K, 535 SYNC REQ 5
R39 WAS 47K, R94 WAS 22K, R415 WAS 536 RUN - IDLE 4
NU
NU
3
3
3
3
5
5
5
3
5
5
5
5
5
5
5
22K, R416 WAS 68K, C86 WAS .47 mF. 537 SLAVE 5
N R14 WAS 39.2K; R46 WAS 100K 6/26/74
I EX (+) 556
I EX (-) 555
REV PWR RST 554
KVAR MET. 553
NOT USED 552
VOLT REF 551
KW MET 550
SYNC CNTL 549
SYNC SLV 548
SPD REF 547
+11V 546
THROTTLE – 545
M S LOGIC 544
MAST SLV 543
SLAVE 542
SLAVE 541
SLAVE 540
SLAVE 539
538 SLAVE 5 SHT
D159 - K WAS TO PIN 534
M C109 WAS .22 @ 100V – R8/R82 à3.3K 5/17/74
2 . OP AMP VOLTAGE PINS:
C110 WAS .47 @ 100V - R9/R83 à 470
Z1 – Z9 PIN 4 = -15 PIN 7 = +15
L C12 WAS .47 @ 100V 11/19/73 Z10, Z11 PIN 4 = -16 PIN 7= +16
K BOARD REWORKED – ADDED Z12, R415, 7/18/73 1 . AC WIRING DIA SEE 200D203
R416 & C44 NOTES
REVISIONS UNLESS OTHERWISE SPECIFIED ROSS HILL CONTROLS
DIMENSIONS ARE IN INCHES AND AC REGULATOR
No. DESCRIPTION DATE BY
TOLERANCES ARE CORPORATION
J D35 WAS 1N5060 OMIT R409, C42 7/18/73 X . .10 7752 HAMMERLY . HOUSTON, TEXAS 77055
H ADDED WIRE FROM K1-3 TO 554 5/23/73 XX . .020 (713) 688-3758 MODULE SCHEMATIC
ADDED D167 & D168 XXX . .005 2750 E. SPRING ST . LONG BEACH, CALIF. 90806
FRACTIONS (213) 427-7712 DRAWN BY DATE CHKD APPVD JOB NO
G REVISED 5/1/73 ANGULAR THIS IS A PROPRIETARY DESIGN OF ROSS HILL CONTROLS CORP. 12-5-76 5017
F REVISED REPRODUCTION OR USE OF THIS DESIGN BY OTHERS IS PERMISSIBLE ONLY SCALE DRAWING NO REV
E REVISED & REDRAWN 10/3/72 IF EXPRESSLY AUTHORIZED IN WRITING BY ROSS HILL CONTROLS CORP.
SHT1 OF 8 200B128 R