iGEM2-Error Codes and Solutions
iGEM2-Error Codes and Solutions
BOOT LOCK J Pump remain in Bootloader mode. Dispenser application will not
be started until error has been corrected.
IE IFSF U
C S
0 Not used H H H
6 – 15 Not used
21 Reserved
IE IFSF U
C S
26 Reserved
27 Reserved
30 Reserved
31 BAD POWER A A A
32 VBAT ERROR A A A
35 Reserved
36 Reserved
44 – 49 Not used
No. Error/Event Description Classification
IE IFSF U
C S
50 LOG NOZ TOTALIZERS DAMAGED EE Device code = 0 then totalizers have been E A B
cleared, RAM copy also damaged.
56 – 59 Not used
63 Not used
66 LR CONFIGURATIONS DAMAGED DF E C B
68 – 69 Not used
IE IFSF U
C S
73 – 79 Not used
81 Reserved
89 – 98 Not used
IE IFSF U
C S
IE IFSF U
C S
IE IFSF U
C S
190 HW / SW MISSMATCH E E E
198 NOT ENOUGH MEMORY iGEM was not able to save all parameters F F F
in non-volatile storage. Set O704.004 = 1
to clear the error.
Device code:
1 = LR Configuration in D-FLASH
2 = LR Configuration in SRAM
3 = non-LR Configuration in SRAM
IE IFSF U
C S
Device codes:
1 – 4: Primary sales display (A – D)
5 – 8: Secondary sales display (A – D)
9 – 12: Ternary sales display (A – D)
13 – 16: Primary UPD (A – D)
17 – 20: Secondary UPD (A – D)
21 – 24: Ternary UPD (A – D)
25 – 28: Primary Preset display (A – D)
29 – 32: Secondary Preset display (A – D)
33 – 36: Ternary Preset display (A – D)
37 – 38: Extended UPD (A – B)
214 DAUP DEVICE ERROR MINOR Lnoz code indicate status code from B B B
device:
3: Display module error
9: Too many chars received
10: ASCII format error
11: BCD format error
No. Error/Event Description Classification
IE IFSF U
C S
215 DAUP DEVICE ERROR MAJOR Lnoz code indicate status code from B B B
device:
1: RAM error
2: ROM error
4: Device has Reset
7: Device IDPROM CRC error
8: WDOG reset in device
216 DAUP DEVICE SERIAL NO MISSMATCH Daup device has been replaced. If the D B B
change is intentional, confirm the
replacement in O701.002 = 11.
0 = Bus is off
1 = stuff error
2 = form error
3 = ACK error
4 = Bit1 error
5 = Bit0 error
6 = CRC error
7 = Large Msg Tx Timeout
8 = Large Msg Rx Timeout
IE IFSF U
C S
223 ATC FUEL TYPE MISSMATCH Fuel/Density miss match detected by FT- B E B
board
225 ATC FT-BOARD S/N MISS MATCH FT-board has been replaced. C C C
226 ATC VCF OUT OF LIMIT FT-board reported VCF that was out of C C C
limit
227 ATC W&M SWITCH OUT WHEN NOT If attempting to start filling with ATC E E E
SUPPOSED TO W&M switch out or switch is out on exit
and save or reset.
IE IFSF U
C S
237 VRM SHUT-DOWN TIME HAS ELAPSED The 72 – 168 hours (depending on B B B
country) has elapsed since error was
triggered. No further fillings on VR nozzles
are possible.
238 VRM METER SIGNAL ERROR The pump has detected error with the B B B
VRM system.
240 VRM MAX NOF SELF-TEST ERRORS Possible blockage on the suction side A A A
(nozzle or hose).
241 VRM PROTOCOL OFFLINE ERROR No poll from Vapour Gate diagnostic A B B
protocol Master.
IE IFSF U
C S
287 – 289
No. Error/Event Description Classification
IE IFSF U
C S
IE IFSF U
C S
294 ATEX ADDITIVE TANK LEVEL EMPTY Will disable Additive products. B B B
Device code:
1 = Tank 1
2 = Tank 2
Device code:
1 = Tank 1
2 = Tank 2
310 DELIVERY LIMIT OVERRUN Pump could not stop on target delivery B B B
limit.
311 HOSE LEAK TEST LIMIT EXCEEDED Check for leaking nozzle or hose. Could B B B
312 HOSE LEAK TEST MAX CONSECUTIVE Check for leaking nozzle or hose C C C
No. Error/Event Description Classification
IE IFSF U
C S
320 MAX COAST TIMER REACHED Pump could not stop the flow within X E E E
seconds.
F022.005
321 MAX AUTHORIZED TIME REACHED Pump is only allowed to stay in state A A A
AUTHORIZED with nozzle in for X minutes
after which it terminate the release.
F022.003
322 MAX TIME WITH NO FLOW DETECTED No flow was detected for X seconds. B B B
F022.006.
324 MAX TIME WITH FLOW LOST REACHED No flow was detected for X seconds. B B B
F022.007.
IE IFSF U
C S
350 DISPLAY UPD HW/SW MISS MATCH Mappings didn’t match UPD’s available. D D D
357 DISPLAY NO SALES VOLUME DISPLAY Sales display most likely didn’t respond B B B
with IDPROM info.
IE IFSF U
C S
401 METER CALIBRATION DATA DIFFERS Lnoz# indicate what data differed: C C C
FROM DATA STORED ON iGEM 1 = XWIP curve elements
2 = XWIP K-factor
3 = XWIP product type
410 CORIOLIS METER DENSITY ERROR Only logged if in normal operating mode B B B
(not logged in any of the W&M modes)
IE IFSF U
C S
IE IFSF U
C S
440 WIP CALIBRATION DOOR STATUS WIP calibration door opened or closed A A A
CHANGE
503 HYDARULIC CABINET DOOR OPENED Door security feature. Hydraulic door D D D
(F066.005) has been opened when armed.
IE IFSF U
C S
507 COMMUNICATION LOST OVER CAN TO Will trigger an error 501 regardless of door B B B
SECURITY SWITCH BOARD status.
512 SWITCH BOARD or I/O-BOARD: Replace the board since not reliable → F B B
ROM TEST FAILURE possibly false nozzle out.
513 SWITCH BOARD or I&O-BOARD: Replace the board since not reliable → F B B
RAM TEST FAILURE possibly false nozzle out.
521 VALVE ACTIVE FEEDBACK ERROR Valve disconnected when valve was in A A A
active state
IE IFSF U
C S
522 VALVE INACTIVE FEEDBACK ERROR Valve disconnected when valve was in in- A A A
active state
523 MOTOR ACTIVE FEEDBACK ERROR Motor disconnected when valve was in B B B
active state
524 MOTOR INACTIVE FEEDBACK ERROR Motor disconnected when valve was in in- A A A
active state.
531 MPI PULSE OUTPUT LAG Flow exceeds maximum possible pulse B B B
output rate
600-601 Reserved
IE IFSF U
C S
IE IFSF U
C S
801 FACTORY DEFAULT NOT SAVED Factory default data is not saved. G G G
Lnoz# Device#
1 Bit 0 = Task Mbx 1 (LR Wdog
Task)
Bit 1 = Task Mbx 2 (LR Initial
Task)
Bit 2 = Task Mbx 3 (LR Rom Test
Task)
Bit 3 = Task Mbx 4 (LR test
Task)
Bit 4 = Mbx 5 n/a
Bit 5 = Task Mbx 6 (LR Syscon
Task)
Bit 6 = Task Mbx 7 (LR Sales
Task)
Bit 7 = Task Mbx 8 (LR Maint
Task)
2 Bit 0 = Mbx 9 n/a
Bit 1 = Task Mbx 10 (LR iSense
task)
Bit 2 = Task Mbx 11 (LR
Flexmem Task)
Bit 3 = Task Mbx 12 (LR DAUP
Task)
Bit 4 = Task Mbx 13 (LR UART3
Task)
Bit 5 = Task Mbx 14 (LR UART4
Task)
Bit 6 = Task Mbx 15 (LR CAN
Task)
Bit 7 = Task Mbx 16 (LR Display
Task)
3 Bit 0 = Task Mbx 17 (LR WIP
Task)
Bit 1 = Task Mbx 18 (LR ATC
Task)
Bit 2 = Task Mbx 19 (LR Coriolis
Task)
Bit 3 = Mbx 20 n/a
Bit 4 = Task Mbx 21 (LR nonvol
Task)
Bit 5 = Task Mbx 22 (LR EMT
Task)
No. Error/Event Description Classification
IE IFSF U
C S
IE IFSF U
C S