0% found this document useful (0 votes)
11 views2 pages

GS-series Relè

The document provides specifications for GS series gold silver alloy contact switches. It details the main features, contact ratings, applications, performance metrics, coil specifications, and ordering information for the switches. The switches are available in different coil sensitivities and are suited for uses like telecommunications and audio equipment.

Uploaded by

Enrico Boglioli
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views2 pages

GS-series Relè

The document provides specifications for GS series gold silver alloy contact switches. It details the main features, contact ratings, applications, performance metrics, coil specifications, and ordering information for the switches. The switches are available in different coil sensitivities and are suited for uses like telecommunications and audio equipment.

Uploaded by

Enrico Boglioli
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

GS

MAIN FEATURE
1. Gold Silver alloy contact good for low
switching application.
2. 2.54mm terminal pitch employment
equivalent to I.C. Terminal.
3. Different types of coil sensitivity available to
meet user’s selection.
4. Plastic epoxy resin sealed type for washing
procedure.
5. Comply with RoHS and REACH regulations.
CONTACT RATING
Load Type GS (D) GS (T) GS (L)
1A 120VAC 1A 120VAC 1A 120VAC
Rated Load (Resistive)
2A 24VDC 2A 24VDC 2A 24VDC
Rated Carrying Current 2A 2A 2A
AC 120V AC 120V AC 120V
Max. Allowable Voltage
DC 24V DC 24V DC 24V
Max. Allowable Current 2A 2A 2A
120VA 120VA 120VA
Max. Allowable Power Force
48W 48W 48W
Min. Switching Load DC 1V, 1mA DC 1V, 1mA DC 1V, 1mA
Contact Material Ag Alloy Ag Alloy Ag Alloy
Contact Form DPDT DPDT DPDT

APPLICATION Temperature Range .............. -30 +80°C


Humidity Range ..................... 45 85% RH.
Telecommunication, Domestic Appliances,
Coil Temperature Rise .......... 25°C Max. (D Type)
Office Machine, Audio Equipment, Remote Control, etc 20°C Max. (T /L Type)
Vibration:
PERFORMANCE (AT INITIAL VALUE) Destruction ........................ 10 to 55 to 10 Hz,0.75 mm single
amplitude (1.5mm double amplitude)
Contact Resistance ..............100m Max.@100mA, Malfunction ........................ 10 to 55 to 10 Hz,0.75 mm single
6VDC amplitude (1.5mm double amplitude)
Operate Time........................GS-D 6 mSec. Max. Shock:
GS-T/L 8 mSec. Max. Destruction ........................ 1,000 m/S2
2
Release Time .......................4 mSec. Max. Malfunction ........................ 100 m/S
Dielectric Strength: Life Expectancy:
7
Between Coil & Contact ....... 1,000VAC at 50/60 Hz Mechanical.......................... 10 Operations at No
for one minute Load condition
5
Between Contacts ................500VAC at 50/60 Hz Electrical.............................. 10 Operations at
for one minute Rated Resistive Load
Surge Strength .....................1,500V (between coil Weight ................................
.... About 4.8 g
& contact 1.2x50μSec.)
Insulation Resistance ...........100 Mega Min. at
500VDC SAFETY STANDARD & FILE NUMBER
Max. On/Off Switching:
Electrical ...............................6 Cycles per Minute UL & C-UL ............................. E141060 (D,T only)
Mechanical 300 Cycles per Minute

136
COIL SPECIFICATION (AT 20°C)
GS
Power Maximum
Nominal Nominal Coil Resistance Pull-In Voltage Drop-Out
Coil Sensitivity Consumption Allowable
Voltage (VDC) Current (mA) (Ω±10%) (VDC) Voltage (VDC)
(W) Voltage (VDC)
3 120 25
5 71.4 70
6 60.0 100 75% 10%
GS - D 9 40.0 225 Abt. 0.36 Maximum Minimum 150%
12 30.0 400
24 15.0 1,600
48 7.5 6400
3 66.7 45
5 40.0 125
6 33.3 180 75% 10%
GS - T 9 22.2 405 Abt. 0.20 150%
Maximum Minimum
12 16.7 720
24 8.3 2,880
3 50.0 60

GS
5 30.0 167
6 25.0 240 80% 10%
GS - L Abt. 0.15 Maximum Minimum 150%
9 16.7 540
12 12.5 960
24 6.25 3840

ORDERING INFORMATION
GS - SH - 2 12 D
Coil Sensitivity: D: Standard DC
T: Medium DC
L: High DC
Coil Voltage: 03: 3V, 05: 5V, 06: 6V, 09: 9V, 12: 12V, 24: 24V, 48: 48V
Number of Pole: 2: Two Poles
Type of Sealing: SH: RT III Wash Tight
Type: GS

CLASSIFICATION
Model GS
Coil Sensitivity Standard DC Medium DC High DC
Wash Tight GS-SH-2 D GS-SH-2 T GS-SH-2 L

DIMENSION ( ≤ 5mm ± 0.2mm, > 5mm ± 0.3mm, the tolerance of PCB thru hole: +0.1mm)

P.C.B Layout Bottom View


Bottom View

REFERENCE DATA
Coil temp. rise Operate time Life expectancy
Temp. rise (deg.)

Operation (x10 )
Time (msec.)

Coil Power (W) Coil Power (W) Current of load(A)


V.01EZ
www.goodsky.com.tw 137