0% found this document useful (0 votes)
75 views5 pages

Parker Tetpor Air Filter Cartridges C

The document discusses TETPOR AIR sterilization filter cartridges that offer exceptional filtration performance while providing high levels of biosecurity. The cartridges utilize an expanded PTFE membrane validated as sterilizing grade to ensure removal of all airborne bacteria, viruses and bacteriophage. Specifications and performance characteristics of various sizes of the cartridges are provided.

Uploaded by

maaz ahmad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
75 views5 pages

Parker Tetpor Air Filter Cartridges C

The document discusses TETPOR AIR sterilization filter cartridges that offer exceptional filtration performance while providing high levels of biosecurity. The cartridges utilize an expanded PTFE membrane validated as sterilizing grade to ensure removal of all airborne bacteria, viruses and bacteriophage. Specifications and performance characteristics of various sizes of the cartridges are provided.

Uploaded by

maaz ahmad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

TETPOR AIR Filter Cartridges

Lenntech • air / gas filters


[email protected] • expanded PTFE

www.lenntech.com
Tel. +31-15-261.09.00
Fax. +31-15-261.62.89
TETPOR AIR sterilization filter cartridges offer exceptional
filtration performance while providing the highest levels of
biosecurity throughout the process industry.

Operating at ambient temperature conditions, TETPOR AIR


filter cartridges provide a cost-effective filtration solution.
A unique polypropylene prefilter layer extends service life in
heavily contaminated environments.

TETPOR AIR filter cartridges also utilize a well-proven,


inherently hydrophobic expanded PTFE membrane validated as
sterilizing grade in liquid in accordance with ASTM F838-05.
This ensures the removal of all airborne bacteria, viruses
and bacteriophage.

Features and Benefits


• Assured biosecurity with • Steam sterilizable to
absolute rated filtration 142 °C (287.6 °F)

• High flow rates with low • Unique prefilter layer


pressure drops

• High voids volume PTFE


membrane

Note: TETPOR is a registered trademark of Parker domnick hunter

Performance Characteristics

900 1000
14
12 900
800 0 barg 2 barg
Differential Pressure (mbar)

Differential Pressure (mbar)

0 barg 11
Differential Pressure (psi)

Differential Pressure (psi)

800 12
700 10
9 700 10
600
2 barg 8 600
500 7 8
500
400 6
400 6
5
300
4 300
4
200 3
200
2 2
100 100
1
0 0 0 0
0 100 200 300 400 500 600 700 0 20 40 60 80 100 120 140 160 180
Flow (Nm / hr) (air @ 21 °C)
3
Flow (Nm / hr) (air @ 21 °C)
3

10¨ Size (250 mm) Cartridge B Size (65 mm) Cartridge


TETPOR AIR Filter Cartridges

Specifications
Materials of Construction Effective Filtration Area (EFA) Quality Standards
 Filtration Membrane: Expanded PTFE 10¨ (250 mm): 0.77 m2 (8.28 ft2) Pharmaceutical grade products are
 Upstream Support: Polypropylene K Size: 0.36 m2 (3.87 ft2) manufactured in accordance with cGMP,
 Downstream Support: Polypropylene A Size: 0.25 m2 (2.69 ft2) 100% flushed with pharmaceutical grade
B Size: 0.12 m2 (1.29 ft2) purified water and integrity tested prior to
Filter Cartridges E Size: 0.06 m2 (0.64 ft2) despatch. A sample of each lot is tested to
 Inner Support Core: Polypropylene Syringe ø50 mm: 14.50 cm2 (2.25 in2) demonstrate conformity to validated claims.
 Outer Protection Cage: Polypropylene
 End Caps: Polypropylene Sterilization
 End Caps Insert: 316L Stainless Steel Autoclave Steam-in-Place
 Standard o-rings/gaskets: Silicone Cycles Temp Cycles Temp
(30 min.)

MURUS Disposable Filter Capsules Cartridges 120 142 °C (287.6 °F) 120 142 °C (287.6 °F)
MURUS 5 130 °C (266 °F) - -
 Core: Polypropylene
DEMICAP 100 135 °C (275 °F) - -
 Sleeve: Polypropylene
Syringe 1 130 °C (266 °F) - -
 Standard o-rings: Viton
 Capsule Body: Polypropylene For detailed operational procedures and
 Capsules Vent Seals: Silicone advice on cleaning and sterilization, please
contact the Technical Support Group through
DEMICAP Filter Capsules your usual Parker domnick hunter contact.
 Core: Polypropylene
 Sleeve: Polypropylene Food and Biological Safety
 End Caps: Polypropylene Materials conform to the relevant
 Capsule Body: Polypropylene requirements of 21CFR Part 177 and current
 Capsules Vent Seals: Silicone USP Plastics Class VI - 121 °C and
 Filling Bell: Polycarbonate ISO10993 equivalents.

Syringe Filters
 Body: Polypropylene

Recommended Operating Conditions


Filter Cartridges
Up to 60 °C (140 °F) continuous operating
temperature and higher short-term
temperatures during CIP to the following
limits:
Temperature Max. Forward dP
°C °F (bar) (psi)
20 68 5.0 72.5
40 104 4.0 58.0
60 140 3.0 43.5
80 176 2.0 29.0
90 194 1.7 24.6

MURUS Disposable Filter Capsules


Up to 25 °C ( 77 °F) @ 5.5 barg (79.7 psig)
Up to 60 °C (140 °F) @ 2.8 barg (40.6 psig)

Parker Hannifin certify that this product complies with the


European Council Pressure Equipment Directive (PED) 97/23/
EC Article 3, Paragraph 3 - Sound Engineering Practice (SEP).
This product is intended for use with Group 1 & 2 Dangerous
and Harmless Liquids and Group 2 Harmless Gases at the
operating conditions stated in this document : In compliance
with PED Article 3, Paragraph 3, SEP, this product does not
bear the CE mark.

DEMICAP Filter Capsules


Up to 40 °C (104 °F) at line pressures up to
5.0 barg (72 psig).
TETPOR AIR Filter Cartridges

Performance Characteristics
TOC / Conductivity Oxidizable Substances Retention Characteristics
The filtrate quality from a 10¨ (250 mm) TETPOR AIR filter cartridges meet TETPOR AIR filter cartridges are
TETPOR AIR conforms to the requirements current USP and EP quality standards for validated by bacterial challenge testing with
of current USP <643> (TOC) and USP <645> sterile purified water for oxidizable Brevundimonas diminuta to current ASTM
(conductivity). substances following a <1 litre water flush. F838-05 methodology (107 organisms / cm2
EFA minimum) with typical in-house
Endotoxins Integrity Test Data challenge levels being 1011 organisms per
Aqueous extracts from the 10¨ (250 mm) All filters are integrity testable to the 10¨ (250 mm) filter cartridge.
TETPOR AIR contain < 0.25 EU / ml when following limits when wet with 60 / 40 :
tested in accordance with the Limulus IPA /water and using air as the test gas.
Amoebocyte Lysate test. Cartridge Test Diffusional Water Water Water
Pressure Flow Intrusion Intrusion Flow
Test Pressure
Non-Volatile Extractables (NVE) (barg) (psig) (ml / min) (barg) (psig) (ml / 10 min) (µl / 10 min)

Total NVEs extracted in the first 5 litre E 0.8 11.6 1.5 2.5 36.3 1.3 371

flush of purified water for a 10¨ (250 mm) B 0.8 11.6 3.0 2.5 36.3 2.6 742
A 0.8 11.6 6.0 2.5 36.3 5.3 1514
cartridge are <5 mg.
K 0.8 11.6 8.5 2.5 36.3 7.5 2142
10¨ 0.8 11.6 18.0 2.5 36.3 16.0 4571
Pharmaceutical Validation
A full validation guide is available upon
request from Laboratory Services Group
(LSG).
TETPOR AIR Filter Cartridges

Ordering Information
Cartridges

ZCMT / -

Code ǀ Length (Nominal) Code ǀ Micron Code ǀ Endcap (10¨) Code ǀ Variant Code ǀ O-rings
B* 2.5¨ (65 mm) 020 0.2 µm B* dh DOE A Air / Gas E EPDM
A* 5¨ (125 mm) C BF / 226 Bayonet P PTFE Encapsulated Silicone
K 5¨ (125 mm) D Fin / 222 S* Silicone
1 10¨ (250 mm) E Flat Top / 222 V Viton
2 20¨ (500 mm) F BF / 216/218
* Silicone o-ring supplied as standard without
3 30¨ (750 mm) G Recess / 222 having to specify the ‘S’ code.
H UF Retrofit
* Supplied in packs of 3. R BF / 222 Bayonet

* EPDM gaskets supplied as standard.

Code ǀ Endcap (Demi)


SK Retrofit
T TRUESEAL
X 116
Y Demi Stub
Z Demi A & B Std

MURUS Capsules

ZLMT - - -

Code ǀ Length (Nominal) Code ǀ Micron Code ǀ Inlet Connection Code ǀ Outlet Connection Code ǀ Variant Code ǀ Grade Code ǀ Design Code ǀ O-rings
K 5¨ (125 mm) 020 0.2 µm A / ¨ Tri-Clamp
3 4
A / ¨ Tri-Clamp
3 4
A Air / Gas N Non-sterile L In-Line E EPDM
1 10¨ (250 mm) B 11/2¨ Tri-Clamp B 11/2¨ Tri-Clamp T* T-Port S* Silicone
2 20¨ (500 mm) D 1¨ Hosebarb D 1¨ Hosebarb V Viton
* Only available with a
3 30¨ (750 mm) T 1¨ Tri-Clamp T 1¨ Tri-Clamp 1¨ Tri-Clamp.
* Silicone o-ring supplied
as standard without
having to specify the
‘S’ code.

DEMICAP Capsules

ZEMT - -

Code ǀ Length (Nominal) Code ǀ Micron Code ǀ Inlet Connection Code ǀ Outlet Connection Code ǀ Variant Code ǀ Grade Code ǀ Pack N°
E 4.4¨ (113 mm) 020 0.2 µm T 1¨ Tri-Clamp T 1¨ Tri-Clamp A Air / Gas N Non-Sterile 3 Pack of 3
B 5.5¨ (140 mm) N 1
/2¨ NPT Male N 1
/2¨ NPT Male
A 7.9¨ (200 mm) H 1
/2¨ Hosebarb H 1
/2¨ Hosebarb
G Stepped Hosebarb G Stepped Hosebarb
M 1
/4¨ NPT Male M 1
/4¨ NPT Male
Q Walther QC Q Walther QC
R Grommel / QC R Grommel / QC
V 3
/8¨ NPT Female V 3
/8¨ NPT Female

Syringe Filters

ZSMT - -

Code ǀ Diameter Code ǀ Micron Code ǀ Inlet Connection Code ǀ Outlet Connection Code ǀ Variant Code ǀ Grade Code ǀ Options Code ǀ Pack N°
050 50 mm 020 0.2 µm G Stepped Hosebarb G Stepped Hosebarb P Pharmaceutical N Non-sterile S Standard 025 25 per box
L 1
/8¨ NPT Male L 1
/8¨ NPT Male

Parker domnick hunter has a continuous policy of product development and although the Company reserves the right to change specifications, it attempts to keep customers informed of any alterations. This publication is for general information only and customers are requested to contact
our Process Filtration Sales Department for detailed information and advice on a products suitability for specific applications. All products are sold subject to the company’s Standard conditions of sale. DS_GF_06_01/12 Rev. 4B
The below Parker TETPOR Liquid‐series cartridge filters are all the models that are potentially possible in all variations.
Please note that not all models are actually produced or on stock and some model numbers and names have become obsolete.
Nevertheless this should help as cross reference table chart for Cuno filters nomenclature.
TETPOR Air

ZCMTB‐020B ZCMTA‐020B ZCMTB‐020B ZCMTA‐020B ZCMTK‐020B ZCMT1‐020B ZCMT2‐020B ZCMT3‐020B


ZCMTB‐020C ZCMTA‐020C ZCMTB‐020C ZCMTA‐020C ZCMTK‐020C ZCMT1‐020C ZCMT2‐020C ZCMT3‐020C
ZCMTB‐020D ZCMTA‐020D ZCMTB‐020D ZCMTA‐020D ZCMTK‐020D ZCMT1‐020D ZCMT2‐020D ZCMT3‐020D
ZCMTB‐020E ZCMTA‐020E ZCMTB‐020E ZCMTA‐020E ZCMTK‐020E ZCMT1‐020E ZCMT2‐020E ZCMT3‐020E
ZCMTB‐020G ZCMTA‐020G ZCMTB‐020F ZCMTA‐020F ZCMTK‐020F ZCMT1‐020F ZCMT2‐020F ZCMT3‐020F
ZCMTB‐020R ZCMTA‐020R ZCMTB‐020G ZCMTA‐020G ZCMTK‐020G ZCMT1‐020G ZCMT2‐020G ZCMT3‐020G
ZCMTB‐020SK ZCMTA‐020SK ZCMTB‐020H ZCMTA‐020H ZCMTK‐020H ZCMT1‐020H ZCMT2‐020H ZCMT3‐020H
ZCMTB‐020T ZCMTA‐020T ZCMTB‐020R ZCMTA‐020R ZCMTK‐020R ZCMT1‐020R ZCMT2‐020R ZCMT3‐020R
ZCMTB‐020Y ZCMTA‐020Y ZCMTB‐020SK ZCMTA‐020SK ZCMTK‐020SK ZCMT1‐020SK ZCMT2‐020SK ZCMT3‐020SK
ZCMTB 020Z
ZCMTB‐020Z ZCMTA
ZCMTA‐020Z
020Z ZCMTB
ZCMTB‐020T
020T ZCMTA
ZCMTA‐020T
020T ZCMTK
ZCMTK‐020T
020T ZCMT1
ZCMT1‐020T
020T ZCMT2
ZCMT2‐020T
020T ZCMT3
ZCMT3‐020T
020T
ZCMTB‐020T ZCMTA‐020T ZCMTB‐020X ZCMTA‐020X ZCMTK‐020X ZCMT1‐020X #REF! ZCMT3‐020X
ZCMTB‐020Y ZCMTA‐020Y ZCMTB‐020Y ZCMTA‐020Y ZCMTK‐020Y ZCMT1‐020Y ZCMT2‐020Y ZCMT3‐020Y
ZCMTB‐020Z ZCMTA‐020Z ZCMTB‐020Z ZCMTA‐020Z ZCMTK‐020Z ZCMT1‐020Z ZCMT2‐020Z ZCMT3‐020Z

ZLMTK‐020A ZLMT1‐020A ZLMT2‐020A ZLMT3‐020A


ZLMTK‐020B ZLMT1‐020B ZLMT2‐020B ZLMT3‐020B
ZLMTK‐020D ZLMT1‐020D ZLMT2‐020D ZLMT3‐020D
ZLMTK‐020T ZLMT1‐020T ZLMT2‐020T ZLMT3‐020T

ZEMTE‐020T ZEMTB‐020T ZEMTA‐020T ZSMT050‐020G


ZEMTE‐020N ZEMTB‐020N ZEMTA‐020N ZSMT050‐020L
ZEMTE‐020H ZEMTB‐020H ZEMTA‐020H
ZEMTE‐020G ZEMTB‐020G ZEMTA‐020G
ZEMTE‐020M
ZEMTE 020M ZEMTB‐020M
ZEMTB 020M ZEMTA‐020M
ZEMTA 020M
ZEMTE‐020Q ZEMTB‐020Q ZEMTA‐020Q
ZEMTE‐020R ZEMTB‐020R ZEMTA‐020R
ZEMTE‐020V ZEMTB‐020V ZEMTA‐020V

You might also like