The document provides an overview of the components and connections that make up the control system for a MORI SEIKI M720BM CNC machine. It details the main NC control card, operation panel I/O card, battery backup unit, base I/O card, and optional extension board. Wiring diagrams and component descriptions are included to explain the connections and functions within the electrical cabinet.

Uploaded by

Luis Leal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
220 views

M720BM Class Power Point

The document provides an overview of the components and connections that make up the control system for a MORI SEIKI M720BM CNC machine. It details the main NC control card, operation panel I/O card, battery backup unit, base I/O card, and optional extension board. Wiring diagrams and component descriptions are included to explain the connections and functions within the electrical cabinet.

Uploaded by

Luis Leal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

M720BM CNC

Control for
MORI SEIKI
General System Diagram for M720BM
MAIN NC CARD HN623/HN682

PWGD Led
SW3 (not used)
SW2
SW1 (not used)
12V Connection

Battery Connection
(not used)

EXT connection
used for additional
cards

Connection to
Op Panel I/O

SW2 Settings
Connection
to Base I/O 0 – normal run
1 – PLC Stop
C – SRAM Clear
INSTALATION OF MAIN NC CARD HN623/HN682

Data Stored on NC Card


SRAM FROM
•Machining Programs •PLC
•Offsets •Option Parameters
•Parameters •Mitsubishi Software
OPERATION PANEL I/O CARD HN376

HN376-01 (old style) HN376-02 (new style)

HN377
HN376D

HN376C

M720BM M720BM/M730BM
HN376 CONNECTION TO MAIN NC CARD
NOTE: These two boards will not operate separately

12V Line
necessary to
support NC Card

Communication Cable
Contains the Battery Voltage, RS232,
Emergency Stop signal and Remote
I/O communication
CONNECTIONS USED ON MORI NL MACHINES
Mori
Operation
Panel

Battery

Emergency
Stop

Hand
Wheel

24V Input
HN376/HN377 SETTINGS AND LED’s

F1 (13) & F2 (14)


Removable fuses

CS1 (15) & CS3 (16)


Rotary Switches
(not recommended
to change)

NC 7-segment display

NCWD Watch Dog

NCOK NC operation OK

24VIN 24V is good

EMG1 Emergency Stop EMG2 Emergency EMG24V 24V supply to EMG


Button Status Status connector from HN377 is good
NEW STYLE HN376
This board combines both of the old HN376 and HN377 into one board.
FCU6-BTBOX BATTERY

SRAM Data to be
G240 Cable

Internal Board
Connection backed up by
Battery during
power Off

F011 Cable
FCU6-BTBOX BATTERY
Outside of Electrical Cabinet Inside of Electrical Cabinet

The BTBOX contains two batteries. These batteries can be found at Radio Shack
or comparable store or by doing a search on the internet for 2CR5.
BASE I/O HR378

Input and Output connections to


Mori Relay Board

HR378

5V Input Needed

24V Input

Hand Wheel Not used


BASE I/O HR378

Remote I/O Units

Tool Setter Probe or


similar device

MDS Drives
RS232 (cannot use
this port on M720BM)

Ground
Points
HR378 SETTINGS
FCUA-DX101
(Same as M60 Series)

Connection Input Signals


to Base I/O

Station No.
setting (not
recommended
to change, this
will change PLC
addressing)

24V
Output Signals
EXTENSION BOARD HN692

Functions
•Data Server Option
•Additional Memory
•Optical Port for newer series
drive units
•CF slot for input/output of
programs through Mitsubishi
Screens
•12V Connector

Note: This is an optional board


usually installed by Mitsubishi
EXTENSION BOARD HN692

Extension Board

Main NC Board
When Extension Board is installed 12V line plugs into extension
board and is transferred to NC Board through G280 cable
OVERVIEW OF M720BM CONTROL LAYOUT