LHFL SERIES L

LED Flood Lighting for Hazardous Locations


H
F
• Class I, Division 2, Groups A, B, C & D
• Class II, Divisions 1 & 2, Groups E, F & G
L
• Class III
• Zone 2, Groups IIA, IIB & IIC
• UL 844 Hazardous Locations
• UL 1598A Marine Outside Type
• UL 1598 Wet Locations
• UL 8750 LED Safety
• 65°C Ambient Temperature (Class I, Division 2)
• 55°C Ambient Temperature (Class II & III)
• CAN/CSA C22.2 No. 250.0-08
• CAN/CSA C22.2 No. 137-M1981
• ABS Type Approved
• Cast Aluminum
• IP66
• NEMA 4X
• Tested to LM79, LM80 Standards
LHFL FLOODLIGHT SERIES LED Flood Lighting for Hazardous Locations

Low copper content aluminum


construction (Less than 0.4%
copper). Corrosion and chemical
resistant baked-on epoxy finish.

Optional dark sky visor.

Cree® XLamp
XML LEDs. 5000K CCT Standard.
Other CCTs available.

Marine-grade stainless
steel hardware.

Precision formed specular reflector for


optimum photometric performance.

7H x 6V beam pattern standard.

High impact clear glass lens.


Polycarbonate lens available 360° Rotation
as an option for Class I & II, mounting yoke.
Division 2 applications only. Optional polished
stainless steel wire
guard.

Safety chain for access cover.

Dual 3/4in. NPT hubs Optional eye bolt.

RIG-A-LITE
LED
LHFL Series
Hazardous Locations • Cast Aluminum • Class I, Divsion 2 • Class II • Class III • UL 1598A • UL 844

Catalog Number Logic

LHFL-20- L-U-T-76-XX
1 2 3 4 5 6 7

1 BASIC SERIES 5 MOUNTING


LHFL = Hazardous Locations/Marine Flood Light T = Trunnion
Class I, Division 2, Groups A, B, C & D
Class II, Division 1, Groups E, F & G
Class III 6 BEAM DISTRIBUTION
76 = 7H x 6V    
Zone 2, Groups IIA, IIB & IIC
UL 844 Hazardous Locations
UL 1598A Marine Outside Type
UL 8750 LED Safety 7 OPTIONS2
CAN/CSA C22.2 EB = Eye Bolt
NEMA 4X FB1 = Single Fuse Block1,3
IP66 FB2 = Double Fuse Block1,3
SP = Surge Protector1
SC = Safety Cable (Eye Bolt Included)
PC = Polycarbonate Lens (for Class I & II, Div. 2)
2 INPUT WATTS 35 = 3500K CCT
40 = 4000K CCT
07 = 70W
15 = 130W 56 = 5600K CCT
20 = 188W

3 LAMP TYPE
L = LED
1 Voltages for fuse block and surge protector.

4
2 Consult factory for pricing.
VOLTAGE/FREQUENCY 3 Not for Marine application.

U = 120 thru 277V 50/60 HZ


N = 347/480V 60 HZ
12 = 120V 60 HZ1
22 = 220V 60 HZ1
24 = 240V 60 HZ1
27 = 277V 60 HZ1
34 = 347V 60 HZ1
48 = 480V 60 HZ1

Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.

www.rigalite.com
RIG-A-LITE
LED
LHFL Series
Hazardous Locations • Cast Aluminum • Class I, Divsion 2 • Class II • Class III • UL 1598A • UL 844

• Class I, Division 2, Groups A, B, C & D


• Class II, Division 1, Groups E, F & G
• Class III
• Zone 2, Groups IIA, IIB & IIC
• UL 844 Hazardous Locations
• UL 1598A Marine Outside Type
• UL 8750 LED Safety
• CAN/CSA C22.2
• Low copper content cast aluminum housing with baked on gray epoxy powder
coat finish
• Precision formed specular finished reflector for optimum photometric performance
• Thermal shock, heat and impact-resistant tempered glass lens
• Marine grade stainless steel hardware
• -20 C to 65° C Ambient Temperature (Class I, Division 2)
• -20° C to 55° C Ambient Temperature (Class II, Divisions 1 & 2; Class III)
• IP66
• NEMA 4X
• 360° Rotation mounting yoke

Shipping*
Fixture Wattage Voltage Catalog Numbers
Weight (Lbs.)
70W 120 thru 277V 50/60HZ LHFL-07-L-U-T-76 38
70W 347/480 60HZ LHFL-07-L-N-T-76 42

130W 120 thru 277V 50/60HZ LHFL-15-L-U-T-76 40

130W 347/480 60HZ LHFL-15-L-N-T-76 44

188W 120 thru 277V 50/60HZ LHFL-20-L-U-T-76 41


188W 347/480 60HZ LHFL-20-L-N-T-76 45
* For Actual Luminaire Weight, Subtract 3 lbs.
LED
LHFL Series
Hazardous Locations • Cast Aluminum • Class I, Divsion 2 • Class II • Class III • UL 1598A • UL 844

Photometric Data
LFHL07LUT76 @ 40 Ft High; Tilt Angle = 45°
(ISOFOOTCANDLES) LHFL07LUT76XX
Total Lumens 6918.94
Input Power
65.24
(Watts)
Efficacy
106.05
(Lumens/Watt)
CRI 71.7
CCT 5108

LFHL15LUT76 @ 40 Ft High; Tilt Angle = 45°


(ISOFOOTCANDLES) LHFL15LUT76XX
Total Lumens 13562.18
Input Power
129.77
(Watts)
Efficacy
104.51
(Lumens/Watt)
CRI 72.6
CCT 5088

LFHL20LUT76 @ 40 Ft High; Tilt Angle = 45°


(ISOFOOTCANDLES)
LHFL20LUT76XX
Total Lumens 19518.1
Input Power
187.52
(Watts)
Efficacy
104.09
(Lumens/Watt)
CRI 75.13
CCT 5218

Certification Guide

www.rigalite.com
RIG-A-LITE
LED
LHFL Series
Hazardous Locations • Cast Aluminum • Class I, Divsion 2 • Class II • Class III • UL 1598A • UL 844

Fixture Dimensions (inches)

Accessories

Catalog Catalog
Guard Number Visor Number

86009 86036P