0% found this document useful (0 votes)
45 views2 pages

Des & Technical Sheet Bilaspur-R0

The document provides technical specifications for a proposed building including dimensions, loadings, materials, design criteria, and a breakdown of structural components and weights. Key details include a non-expandable steel framed building that is 50m wide and 90m long with a clear height of 11m. Roof and wall materials include galvalume sheeting. Design is according to AISC and serviceability criteria from MBMA. The tonnage breakdown lists elements like built up steel, crane beams, secondary members, and accessories with a total structural weight of around 157,466kg.

Uploaded by

Hasmukh Tank
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
45 views2 pages

Des & Technical Sheet Bilaspur-R0

The document provides technical specifications for a proposed building including dimensions, loadings, materials, design criteria, and a breakdown of structural components and weights. Key details include a non-expandable steel framed building that is 50m wide and 90m long with a clear height of 11m. Roof and wall materials include galvalume sheeting. Design is according to AISC and serviceability criteria from MBMA. The tonnage breakdown lists elements like built up steel, crane beams, secondary members, and accessories with a total structural weight of around 157,466kg.

Uploaded by

Hasmukh Tank
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

REV NO REV-0 BLDG BLDG#1 DESIGN HASMUKH

CUSTOMER NAME -- CHECKED YB


LOCATION BILASPUR, UP DATE 17/01/2024
CONSULTANT SALES ENGG.

TECHNICAL DATA SHEET


TYPE : SCMS-1
QTY. OF MEF : Non expandable light end frame
WIDTH : 50.000 meter O/O of Steel Line
LENGTH : 90.000 meter O/O of Steel Line
CLEAR HEIGHT : 11.000 meter 8.0M CRANE HEIGHT
ROOF SLOPE : 1:10
BAY SPACING : [email protected]
INT COL SPACING : [email protected]
END WALL COL SPACING : [email protected]
ROOF SHEETING : SRS 0.475mm thk Colour Galvalume BARE Coated
WALL SHEETING : SWS 0.5mm thk TCT Colour Galvalume RMP Coated
GABLE SHEETING : SWS 0.5mm thk TCT Colour Galvalume RMP Coated
WALL CONDITION
From FFL LVL. SIDE WALL-1 3.00m Height Brickwall & above sheeted
From FFL LVL. SIDE WALL-2 3.00m Height Brickwall & above sheeted
From FFL LVL. END WALL-1 3.00m Height Brickwall & above sheeted
From FFL LVL. END WALL-2 3.00m Height Brickwall & above sheeted

2
LOADINGS : DL : KN /m LL : KN /m2 WS : m/sec AUX : KN /m2 SEISMIC ZONE
0.12 0.57 47 * IV
WIND EXPOSURE
C
ADDITIONAL LOADINGS :-
1 nil
2

DESIGN ACCORDING TO:

Wind Load application as per MBMA-96, Design According to AISC -1989 and Serviceability according to MBMA -1996

MIN THICKNESS CRITERIA :


PRIMARY SECONDARY
MIN THICKNESS(MM) 5.0 1.5 275 GSM

BRACING SYSTEM : ROOF SIDEWALL INTERIOR LINE END WALL


BRACING ROD TUBE+ROD TUBE+ROD N/A

CRANE DATA :
Crane-1
Crane type EOT Safex
Capacity 10.00 MT
Bridge weight 11.05 MT
Wheel load 8.24 MT
Total no of wheels 4.00 No's
Wheel base 3.80 m
No of cranes 2.00 No's ONE CRANE EACH BAY
Crane hook height 8.00 m
Crane Span 25.00 m
Crane Run Length 90.00 m
Tandem operation YES
Crab weight 1.23 MT

FRAMED OPENINGS CANOPY

USES QUANTITY WIDTH HEIGHT QUANTITY(Nos) WIDTH(M) LENGTH(M) EAVE TYPE

CURVED EAVES WITHOUT


RS 2 4.0 4.0 2 2.00 6.250 SOFFIT

Serviceability Criteria(Deflection check) as per MBMA-1996.

Main Frame Rafter Purlins Girts Crane Beam Mezz Beam/ Joist Main Frame With Crane Without Crane

Vertical
L/180 L/150 L/120 L/600 L/240 Lateral Deflection H/100 H/90
Deflection

IMPORTANT NOTES, DEVIATIONS & ASSUMPTIONS:-

1) Framed openings Header & Jamb Considered as COLD FORM Member.


2) All columnS support considered as PINNED BASE & Wind Column considered Pinned Base.
3) Rainfall intensity considered for design of gutter &downspout is 100 mm/hour.
4) 1 No Cage Ladder considered for Roof Access
5) Single Galvalume Downtake Pipe is considered at all SW Column Location. (1.2m Below FFL)
6) One no. staircase considered for mezz.
7) Handrails one end of mezzanine considered.
QRF NO REV-0 BLDG BLDG#1 DESIGN HASMUKH

CUSTOMER NAME -- CHECKED YB

LOCATION BILASPUR, UP DATE 17/01/2024

CONSULTANT 0 SALES ENGG. 0

TONNAGE BREAKUP, ACCESSORIES AND BUYOUTS


WEIGHT
BREAK DOWN
(MT)
Built up-50 ksi 81.43 SSW

HR miscellaneous 6.88

Crane beam -50 ksi DSW 33.05

Secondary (Cold-Form) 32.39

Roof sheeting 20.09

Wall sheeting 11.95

Wall accessories 2.82

Anchor bolts 3.00

Cage Ladders 0.71 (1# For Roof access with platform)

TOTAL AREA OF THE BUILDING 4528


Hardware(HSB) 3.72 TOTAL STRUCTURAL WEIGHT (KG) 157466.20
TOTAL STRUCTURAL WEIGHT (KG/M2) 34.78
TOTAL BUILDING WEIGHT (KG) 196046.15
TOTAL BUILDING WEIGHT (KG/M2) 43.30
TOTAL 196.0

WEIGHT
TONNAGE BREAKUP FOR PRICING
(MT)
Built up-50 ksi 114.48

HR miscellaneous 7.59

Secondary 32.39

Roof sheeting 20.09

Wall sheeting 11.95

Wall accessories 2.82

Chequered Plate- 5 mm 0.00

Deck Sheet 0.8mm thk 0.00

Anchor bolts 3.00

HSB 3.72

TOTAL 196.0

S.NO BUY-OUT ITEMS

Standard Accessories Bldg-A

( 3 % of Roof Area) GROSS AREA


1 Sky light (1m x 3m) 145 SQM

Roof plan and Wall areas of building as mentioned below.


UNIT : m2 Bldg-A
~ROOF AREA 4518

~CANOPY AREA 28

~WALL AREA 2609

G.I 75x75x1.6
WELD MESH Area (m2) MT
Sky Lights 160

b) PAINTING:

i) PAINTING : FINISH -2- coat of low VOC epoxy primer (50 micorn DFT) paint proved colour

PRIMARY:
Bldg Tonnage(MT)
A 122.07