HD-12LS-B Manual REV C 10-24-07
HD-12LS-B Manual REV C 10-24-07
PRODUCT WARRANTY
BendPak 4-Post Lifts are warranted for five years on equipment structure, to be free of defects in material and work-
manship. Power units, hydraulic cylinders, and all other assembly components such as turnplates, slip plates, cables,
chains, valves, switches etc. are warranted for one year against defects in material or workmanship under
normal use. BendPak Inc. shall repair or replace at their option for the warranty period those parts returned to the
factory freight prepaid which prove upon inspection to be defective. BendPak Inc. will pay labor costs for the first 12
months only on parts returned as previously described.
THESE WARRANTIES DO NOT EXTEND TO ANY COSMETIC DEFECT NOT INTERFERING WITH EQUIPMENT
FUNCTIONALITY OR ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT
MAY RESULT FROM ANY DEFECT, FAILURE, OR MALFUNCTION OF A BENDPAK INC. PRODUCT OR THE
BREACH OR DELAY IN PERFORMANCE OF THE WARRANTY.
Receiving:
The shipment should be thoroughly inspected as soon as it
DANGER is received. The signed bill of lading is acknowledgement by
Watch for this symbol: It Means: Immediate hazards the carrier of receipt in good condition of shipment covered
which will result in severe personal injury or death. by your invoice. If any of the goods called for on this bill of
lading are shorted or damaged, do not accept them until the
carrier makes a notation on the freight bill of the shorted or
damaged goods. Do this for your own protection.
3
TABLE OF CONTENTS
4
INSTALLER / OPERATOR
PLEASE READ AND FULLY UNDER-
STAND.
BY PROCEEDING YOU AGREE TO
THE FOLLOWING. Failure to follow danger, warning, and caution
instructions may lead to serious personal injury or death
to operator or bystander or damage to property.
I have visually inspected the site where the lift is to be
installed and verified the concrete to be in good condition
and free of cracks or other defects. I understand that
installing a lift on cracked or defective concrete could
cause lift failure resulting in personal injury or death.
Please read entire manual prior to installation.
I understand that a level floor is required for proper Do not operate this machine until you read and
installation and level lifting. understand all the dangers, warnings and cautions
in this manual. For additional copies
I understand that I am responsible if my floor is of or further information, contact:
questionable slope and that I will be responsible for all
charges related to pouring a new level concrete slab if
BendPak Inc. / Ranger Products
required and any charges.
1645 Lemonwood Dr.
I understand that the lifts are supplied with concrete Santa Paula, CA. 93060
fasteners meeting the criteria of the American National
1-805-933-9970
Standard "Automotive Lifts - Safety Requirements for
Construction, Testing, and Validation" ANSI/ALI ALCTV- www.bendpak.com
1998, and that I will be responsible for all charges related
to any special regional structural and/or seismic anchoring INSTALLER / OPERATOR
requirements specified by any other agencies and/or
PROTECTIVE EQUIPMENT
codes such as the Uniform Building Code (UBC) and/or
International Building Code (IBC).
Personal protective equipment helps makes installation
and operation safer, however, it does not take the place of
I will assume full responsibility for the concrete floor safe operating practices. Always wear durable work
and condition thereof, now or later, where the above clothing during any installation and/or service activity.
equipment model(s) are to be installed.Failure to follow Shop aprons or shop coats may also be worn, however
danger, warning, and caution instructions may lead to loose fitting clothing should be avoided. Tight fitting
serious personal injury or death to operator or bystander leather gloves are recommended to protect technician
or damage to property. hands when handling parts. Sturdy leather work shoes
with steel toes and oil resistant soles should be used by all
I understand that Bendpak lifts are designed to be service personnel to help prevent injury during typical
installed in indooor locations only. Failure to follow instal- installation and operation activities.
lation instructions may lead to serious personal injury or
Eye protection is essential during installation and opera-
death to operator or bystander or damage to property or
tion activities. Safety glasses with side shields, goggles, or
lift
face shields are acceptable. Back belts
provide support during lifting activities and
are also helpful in providing worker protec-
tion. Consideration should also be given to
the use of hearing protection if service
activity is performed in an enclosed area, or if noise levels
are high.
THIS SYMBOL POINTS OUT IMPORTANT SAFETY INSTRUCTIONS WHICH IF NOT FOLLOWED
COULD ENDANGER THE PERSONAL SAFETY AND/OR PROPERTY OF YOURSELF AND OTHERS
AND CAN CAUSE PERSONAL INJURY OR DEATH. READ AND FOLLOW ALL INSTRUCTIONS IN
THIS MANUAL BEFORE ATTEMPTING TO OPERATE THIS MACHINE.
5
INTRODUCTION
1. Carefully remove the crating and packing materials. 2. Check the voltage, phase and proper amperage
CAUTION! Be careful when cutting steel banding requirements for the motor shown on the motor plate.
material as items may become loose and fall causing per- Wiring should be performed by a certified electrician only.
sonal harm or injury.
IMPORTANT SAFETY INSTRUCTIONS
Read these safety instructions entirely!
IMPORTANT NOTICE
Do not attempt to install this lift if you have never been trained on basic automotive lift installation procedures. Never
attempt to lift components without proper lifting tools such as forklift or cranes.
Stay clear of any moving parts that can fall and cause injury.
1. READ AND UNDERSTAND all safety warning proce- 12. GUARD AGAINST ELECTRIC SHOCK. This lift must be
dures before operating lift. grounded while in use to protect the opera-
tor from electric shock. Never connect the
2. KEEP HANDS AND FEET CLEAR. Remove hands and green power cord wire to a live terminal.
feet from any moving parts. Keep feet clear of lift when This is for ground only.
lowering. Avoid pinch points.
13. DANGER! The power unit used on this lift contains high
3. KEEP WORK AREA CLEAN. Cluttered work areas invite voltage. Disconnect power at the recepta-
injuries. cle before performing any electrical repairs.
Secure plug so that it cannot be
4. Consider work area environment. Do not expose accidentally plugged in during service.
equipment to rain. DO NOT use in damp or wet locations.
Keep area well lighted. 14. WARNING! RISK OF EXPLOSION. This equipment has
internal arcing or sparking parts which
5. ONLY TRAINED OPERATORS should operate this lift. should not be exposed to flammable
All non-trained personnel should be kept away from work vapors. This machine should not be located
area. Never let non-trained personnel come in contact with, or in a recessed area or below floor level.
operate lift.
15. MAINTAIN WITH CARE. Keep lift clean for better and
6. USE LIFT CORRECTLY. Use lift in the proper manner. safer performance. Follow manual for proper lubrication and
Never use lifting adapters other than what is approved by the maintenance instructions. Keep control handles and/or
manufacturer. buttons dry, clean and free from grease and oil.
7. DO NOT override self-closing lift controls. 16. STAY ALERT. Watch what you are doing. Use common
sense. Be aware.
8. REMAIN CLEAR of lift when raising or lowering vehicle.
17. CHECK FOR DAMAGED PARTS. Check for alignment
9. CLEAR AREA if vehicle is in danger of falling. of moving parts, breakage of parts or any condition that may
affect its operation. Do not use lift if any component is broken
10. ALWAYS INSURE that the safeties are engaged before or damaged.
any attempt is made to work on or near vehicle.
18. NEVER remove safety related components from the lift.
11. DRESS PROPERLY. Non-skid steel-toe footwear is Do not use lift if safety related components are damaged
recommended when operating lift. or missing.
6
TOOLS REQUIRED
Rotary Hammer Drill or Similar Large Crescent Wrench
3/4" Masonry Bit Large Pipe Wrench
Hammer Crow Bar
4 Foot Level Chalk Line
Open-End Wrench Set: 7/16" - 1-1/8" Medium Flat Screwdriver
Socket And Ratchet Set: 7/16" - 1-1/8" Tape Measure: 25 Foot Minimum
Hex-Key / Allen Wrench Set Needle Nose Pliers
IMPORTANT NOTICE
These instructions must be followed to insure proper installation and operation of your lift. Failure to
comply with these instructions can result in serious bodily harm and void product warranty.
Manufacturer will assume no liability for loss or damage of any kind, expressed or implied resulting
from improper installation or use of this product.
PLEASE READ ENTIRE MANUAL PRIOR TO INSTALLATION.
A level floor is suggested for proper use and installation
STEP 1
and level lifting. If a floor is of questionable slope,
( Selecting Site )
consider a survey of the site and/or the possibility of pour-
ing a new level concrete slab.
Before installing your new lift, check the following.
2. OVERHEAD OBSTRUCTIONS: The area where the lift DO NOT install or use this lift on expansion seams or
will be located should be free of overhead obstructions on cracked or defective concrete.
such as heaters, building supports, electrical lines etc.
DO NOT install or use this lift on a second / elevated
floor without first consulting building architect.
3. DEFECTIVE FLOOR: Visually inspect the site where
the lift is to be installed and check for cracked or defective DO NOT install or use this lift outdoors unless special
consideration has been made to protect the power unit
concrete.
from inclement weather conditions.
IMPORTANT NOTE
The power unit must be installed at the location shown above. It is important to locate the POWER-
SIDE runway ( with cylinder ) on the SAME SIDE as power unit location. Rolling Jack / Utility rails
on the side of each runway MUST be installed to the inside.
8
FLOORPLAN
Diagonal Measurements
Must Be Equal *
* IMPORTANT NOTE *
Check Diagonal Measurements.
To Confirm Square Layout; Diagonal Measurements Must Be Equal.
9
POWER UNIT LOCATION
The power unit will be located at “X” location shown below. It is important to locate the
POWERSIDE runway (with cylinder) on the SAME SIDE as the power unit location.
Note the location of the bulkhead ftting holes in the POWERSIDE runway.
Utility rails on the side of each runway MUST be installed to the inside.
10
STEP 3
( Column & Cross Tube Installation )
Fig. 3.1
Fig. 3.3
Fig. 3.2.
11
5. The columns and cross tubes will now be in position 2. Manually raise the cross tubes until the primary safety locks
and spaced properly for the runways. engage and rest on the lock position second down from the top
of the ladder or approximately 66” off the ground. It is
6. Install the column TOP CAPS using the M10 X 1.50 X important that the SLACK SAFETY LOCK IS CLEARED. The
50 hex bolts, nuts & washers. Install the nut on each slack safety lock must never rest on the safety ladder.
safety ladder until 1/2” of threads are exposed and the lad- (See Fig. 4.1.)
der is raised at least 1/2” off of the base of the column.
NOTE: Raise the ladder at least 1/2” off of the base of IMPORTANT NOTE
It is important that the SLACK SAFETY LOCK IS
the column or damage to the lift will occur. Be sure to
CLEARED. The slack safety lock must never rest on
position the cable hole INWARD. (See Fig. 3.6 - 3.7)
the safety ladder.
Fig. 3.6
Fig. 3.7
Fig. 4.1.
DANGER!
Be careful not to disturb the columns and cross tubes as
they may tip over causing personal injury or harm.
12
STEP 5
( Powerside Runway Installation )
1. Locate the powerside runway easily identified by the
cylinder and sheave roller mounting structures welded on the
underside. The powerside runway will be positioned on the
side of the lift where the power unit is installed. (See Fig. 5.1)
Fig. 5.1
Fig. 5.4
2. Install cylinder and cable block as shown.
(See Fig. 5.2 -5.3.)
STEP 6
( Offside Runway Installation )
Fig. 5.2
Fig. 5.3
Fig. 6.1
13
14
STEP 7 STEP 8
( Cable / Sheave Installation ) ( Cable Installation )
1. Make sure the cylinder flange plate is installed with the guide
IMPORTANT! - Be careful not to damage the chrome rod
assembly facing down and the cylinder retainer plate on the
during this step. (See Fig. 7.1) outside of the guide. Lug ends of cables start at cylinder.
(See Fig. 8.1)
Fig. 7.1
Fig. 8.1
3. You must reinstall the sheaves, spacers and pins in the same
order as they are removed.
(See Fig. 7.2)
Fig. 7.2.
WARNING!
WHEN THE CABLE ADJUSTING NUTS BOTTOM OUT
ON THE THREADED END OF THE CABLE
CONNECTOR AND THERE IS STILL SLACK IN THE
CABLES, THE CABLES HAVE STRETCHED BEYOND
THE SAFE USEFUL LENGTH AND NEED TO BE
REPLACED WITH FACTORY APPROVED CABLE
ASSEMBLIES. DO NOT PLACE WASHERS, SPACERS
OR OTHER DEVICES TO “SHORTEN” THE
EFFECTIVE CABLE LENGTH AS DAMAGE TO THE
LIFT OR INJURY TO PERSONS MAY OCCUR.
15
Fig. 8.2 STEP 9
( Power Unit Installation )
Fig. 9.1
Fig. 8.3
STEP 10
( Routing Hydraulic Hoses )
Fig. 8.4
Fig. 10.1
Fig. 8.5 Fig. 10.2
16
2. Install the two 90-degree fittings at the cylinder ports. On the 4. Connect hoses as shown below making sure to pass
pipe thread side of the fitting it is recommended to use teflon through the retaining rings. MAKE SURE HOSES ARE KEPT
tape or pipe sealer. DO NOT USE TEFLON TAPE on the JIC CLEAR OF CABLES. (See Fig. 10.6 - 10.8)
flared end. (See Fig. 10.3 - 10.4)
Fig. 10.6
Fig. 10.3
Fig. 10.7
Fig. 10.4
Fig. 10.5
Fig. 10.8
17
STEP 11
( Routing Air Lines )
Route the air line as shown below making sure to position the push button air valve with the INLET facing towards the AIR
SOURCE and the OUTLET facing the direction of the COILED AIR HOSE.
A filter/regulator/lubricator must be installed on air supply at lift. Failure to do so will void the warranty. Cut the
provided 1/4" air line tubing with a sharp blade to lengths as required. Tubing must be cut square with no burrs.
Note: To assemble air line tubing into fitting, use firm, manual pressure to push tubing into the fitting until it bottoms out.
To remove air line tubing from the fitting, hold push sleeve in (against fitting) and, at the same time, pull out on tubing.
Pay careful attention to keep air line clear of any pinch points. Improper assembly may result in safety lock failure.
AIR PRESSURE SHOULD BE REGULATED TO 125 PSI MAX. (See Fig. 11.1)
Fig. 11.1
18
DANGER!
IMPORTANT POWER-UNIT
INSTALLATION NOTES
DO NOT run power unit with no oil. Damage to pump can occur.
The power unit must be kept dry. Damage to power unit caused by water or other liquids such as
detergents, acid etc., is not covered under warranty.
Improper electrical hook-up can damage motor and will not be covered under warranty.
Motor can not run on 50HZ without a physical change in motor.
Use a separate breaker for each power unit.
Protect each circuit with time delay fuse or circuit breaker.
For 208-230 volt, single phase, use a 25 amp fuse.
For 208-230 volt, three phase, use a 20 amp fuse.
For 380-440 volt, three phase, use a 15 amp fuse.
Installation and adjustment. DO NOT attempt to raise vehicle until a thorough operation check
has been completed.
Fig. 13.1
IMPORTANT NOTE:
CAUTION Never operate the motor on line voltage
less than 208V. Motor damage may occur which is not
covered under warranty. Have a certified electrician run
appropriate power supply to motor. Size wire for 25
amp circuit. See Motor Operating Data Table.
IMPORTANT: Use separate circuit for each power unit.
Protect each circuit with time delay fuse or circuit
breaker. For single phase 208-230V, use 25 amp fuse.
Three phase 208-240V, use 25 amp fuse. For three
phase 400V and above, use 15 amp fuse. All wiring
must comply with NEC and all local electrical codes.
STEP 14
( Lift Start Up / Final Adjustments )
Fig. 12.1
1. Make sure the power unit reservoir is full with 12 quarts
of 10-WT hydraulic oil or Dexron-III automatic
transmission fluid.
20
5. Check to make sure that all slack safety locks are cleared
and free. (See Fig. 14.1)
Fig. 15.1
Fig. 14.1
NOTE:
There will be initial stretching of the cables in the
beginning and/or with increased loads. Adjust the cables
as outlined above a week after first use, then every
three to six months thereafter depending on usage
and/or to compensate for stretch.
8. After connecting the air supply, press the PUSH BUTTON 3. After drilling, remove dust thoroughly from each hole using
AIR VALVE and check that all safety locks are functioning
compressed air and/or bristle brush. Make certain that the
properly. Lower the lift by pressing the push button air valve
columns remain aligned with the chalk line.
and power unit lowering valve simultaneously.
21
STEP 16
( Attaching Approach Ramps/ Tire Stops )
ALWAYS WEAR SAFETY GOGGLES. 1. Install the approach ramps on the entry side of the lift.
(See Fig. 16.1 - 16.2)
4. Assemble the washers and nuts on the anchors then tap
into each hole with a hammer until the washer rests against Fig. 16.1
the base plate. Be sure that if shimming is required, enough
threads are left exposed. ( See Fig. 15.3)
Fig. 15.3
2. Install the front tire stops at the forward side of the lift using
the M14 x 2 hex bolts, nuts and washers. ( See Fig. 16.3)
6. After any necessary shims are installed, tighten each Fig. 16.3
anchor nut to 35-45 ft./lbs. IMPORTANT - If anchor bolts do
not holed when torqued to required amount, concrete must STEP 17
be replaced. Saw cut and remove 24” x 24” square area ( Leveling / Synchronizing )
under each column base then repour with reinforced 2500
PSI concrete to a depth of six inches minimum, keying new 1. Using an engineer’s automatic Level (transit), locate
concrete under existing floor. (See Fig. 15.5) the Level, at a convenient location in the shop that allows
an unobstructed view of all four corners of the runways.
3. Raise the lift approximately 30"- 40". Then lower the lift
until all primary safeties are engaged in each column and
the runways are completely resting on the primary
Fig. 15.5 safeties.
22
4. Place a Level target on the right/front corner of the 11. Next, load vehicle onto the lift.
runway. (See Fig. 17.1)
12. Raise the lift to full height. Listen and watch as the
5. Beginning with “A” position, sight the level to the target primary safeties enage the safety ladder. Synchronize by
and mark the number or the graduation on the inch scale adjusting the cables so that all four latches click at same
of the target that aligns to the cross hairs of the Level, time. Make necessary adjustments to the cables allowing
(See Fig. 17.1) compensation for stretch.
Fig. 17.1
Note:
Use a pencil, marking pen or attach a paper clip STEP 18
onto the target scale at the crosshair reference. ( Bleeding )
6. Next, move the target and place it at point “B” on the 1. Lift must be fully lowered before changing or adding
runway. (See Fig. 17.1) fluid.
7. Rotate the Level and focus on the target scale. 2. Raise and lower lift six times. The cylinder is self-bleed-
ing. After bleeding system, fluid level in power unit reser-
8. Adjust the adjustment nut on the safety ladder bar at the voir may be down. Add more fluid if necessary to raise lift
top of the column at “B” until the crosshairs of the Level to full height. It is only necessary to add fluid to Raise lift
align to reference mark on the target scale. (See Fig. 17.1) to full height.
9. Repeat steps locating the target assembly at points “C” 3. To pressure test, run lift to full rise and run motor
and “D” and adjusting safety ladders at each correspon- for approximately 3-seconds after lift stops. This will place
ding column until the reference mark on the target scale pressure on the hydraulic system. Stop and check all fit-
is on the crosshairs of the Level. The runways are now tings and hose connections. Tighten or reseal if required.
level at all four points. (See Fig. 17.1)
POST-INSTALLATION CHECK-OFF
10. To complete the leveling procedures, lock each safety
ladder jam nut tightly against bottom of column top plate. Columns Properly Shimmed And Stable
(See Fig. 17.2) Anchor Bolts Tightened
Pivot / Sheave Pins Properly Attached
Fig. 17.2 Electric Power Supply Confirmed
Cables Adjusted Properly
Safety Locks Functioning Properly
Check For Hydraulic Leaks
Oil Level
Lubrication of Critical Components
Check For Overhead Obstructions
Runways Level
All Screws, Bolts, and Pins Secured
Surrounding Area Clean
Operation, Maintenance and Safety Manuals on Site
23
OPTIONAL EQUIPMENT INSTALLATION
24
OPTIONAL EQUIPMENT INSTALLATION
25
STEP 19 To Lower Lift;
(Operation) 1. Before lowering vehicle, be sure all personnel are
To Raise Lift; clear of the lift and surrounding area. Pay careful attention
1. Position vehicle tires in the center of each runway. to overhead clearances. Insure all tools and equipment
have been cleared from under the lift.
2. Set parking brake or use wheel chock to hold vehicle
in position. 2. Raise the lift off of the safety locks by pressing the
push button on the power unit. Make sure you raise the
3. Before raising vehicle, be sure all personnel are clear lift by at least two inches to allow adequate clearance for
of the lift and surrounding area. Pay careful attention to the locks to clear.
overhead clearances. 3. Press the push button air safety valve and HOLD.
4. Raise the lift to the desired height by pressing the 4. Push the LOWERING HANDLE on the power unit
push button on the power unit. until the lift has descended completely.
When lowering the lift PAY CAREFUL ATTENTION that
all personnel and objects are kept clear. ALWAYS keep
a visual line of site on the lift AT ALL TIMES. ALWAYS
VISUALLY CONFIRM THAT ALL PRIMARY make sure that all FOUR LOCKS are disengaged. If one
SAFETY LOCKS ARE ENGAGED BEFORE of the locks inadvertently locks on descent the lift and/or
ENTERING WORK AREA. vehicle may disrupt causing personal injury or death.
Suspension components us on this lift are
intended to raise and lower lift only and are not WEEKLY MAINTENANCE
meant to be load holding devices. Remain
1. Lubricate all rollers with general purpose oil or
clear of elevated lift unless visual confirmation WD-40.
is made that all primary safety locks are fully 2. Check all cable connections, bolts and pins to insure
engaged and the lift is LOWERED onto the proper mounting.
safety locks, Refer to installation /operation 3. Lubricate safety lock pivot points with general
manual for proper safety lock procedures purpose oil or WD-40.
and /or further instruction.
MONTHLY MAINTENANCE
1. Check safety locks to insure they are in good operat-
ing condition.
2. Check all cables for excessive signs of wear.
3. Make a visual inspection of ALL MOVING PARTS and
check for excessive signs of wear.
4. Replace ALL FAULTY PARTS before lift is put back
into operation.
Lifting cables should be replaced every three - five years or when visible signs of damage are apparent. DO NOT
USE LIFT WITH DEFECTIVE / WORN CABLES.
Lifting cables should be maintained in a well-lubricated condition at all times. Wire rope is only fully protected when each
wire strand is lubricated both internal and external. Excessive wear will shorten the life of the wire rope. The factory
suggested wire rope lubricant that penetrates to the core of the rope and provides long-term lubrication between each
individual strand is 90-WT gear oil or ALMASOL® Wire Rope Lubricant. In order to make sure that the inner layers of the
rope remain well lubricated, lubrication should be carried out at intervals not exceeding three months during operation.
All sheaves and guide rollers in contact with the moving rope should be given regular visual checks for surface wear
and lubricated to make sure that they run freely. This operation should be carried out at appropriate intervals generally
not exceeding three months during operation. For all sheave axles, the factory recommends standard wheel bearing
grease. For all sheaves and/or guide rollers, the factory recommends 90-WT gear oil or similar heavy lubricant applied by
any method including pump / spray dispensing, brush, hand and/or swabbing.
.
HOW OFTEN TO INSPECT
Lifting cables should be visually inspected at least once each day when in use, as suggested by American Petroleum
Institute (API) RP54 guidelines.
Any lifting cables that have met the criteria for removal must be immediately replaced.
Flex the rope to expose any broken wires hidden in the valleys between the strands.
Visually check for any broken wires. One way to check for crown breaks is to run a cloth along the rope to check for
possible snags.
With an awl, probe between wires and strands and lift any wires that appear loose. Evidence of internal broken wires
may require a more extensive rope examination.
27
28
29
Safe Lift Operation
Automotive and truck lifts are critical to the operation and profitability of your business. The safe use of this and other
lifts in your shop is critical in preventing employee injuries and damage to customer’s vehicles. By operating lifts safely
you can insure that your shop is profitable, productive and safe.
Safe operation of automotive lifts requires that only trained employees should be allowed to use the lift.
Proper positioning of the vehicle on the runway. (See manufacturers minimize wheel base loading requirements.)
Proper use, understanding and visual identification of safety lock devices and their operation.
Proper housekeeping procedures (lift area should be free of grease, oil, tools, equipment, trash, and other debris)
A daily inspection of the lift should be completed prior to its use. Safety devices, operating controls, lift arms and other
critical parts should be inspected prior to using the lift.
All maintenance and repairs of the lift should be completed by following the manufacturer’s requirements. Lift repair
parts should meet or exceed OEM specifications. Repairs should only be completed by a qualified lift technician.
The vehicle manufacturer’s recommendations should be used for spotting and lifting the vehicle.
It is important that you know the load limit. Be careful that you do not overload the lift . If you are unsure what the load
limit is, check the data plate found on one of the lift columns or contact the manufacturer.
The center of gravity should be followed closely to what the manufacturer recommends.
Always make sure you have proper overhead clearance. Additionally, check that attachments, ( vehicle signs, campers
antennas, etc.) are not in the way.
Be sure that prior to the vehicle being raised, the doors, trunk, and hood are closed securely
Prior to being raised, make sure there is no one standing closer than six feet from the lift
After positioning the vehicle on the lift runways, set the emergency brake, make sure the ignition is off, the doors are
closed, overhead obstructions are cleared, and the transmission is in neutral.
Double check that the automatic chock devices are in position and then when the lift is raised, observe the chocks
Put pads or adapters in the right position under the contact points that have been recommended
The lift should be raised just until the vehicle’s wheels are about one foot off the ground. If contact with the vehicle is
uneven or it appears that the vehicle is not sitting secure, carefully lower the lift and readjust.
Always consider potential problems that might cause a vehicle to slip, i.e., heavy cargo, undercoating, etc.
Pay attention when walking under a vehicle that is up on the hydraulic lift.
30
DO NOT leave the controls while the lift is still in motion.
DO NOT stand directly in front of the vehicle or in the bay when vehicle is being loaded or driven into position.
DO NOT Go near vehicle or attempt to work on the vehicle when being raised or lowered.
DO NOT rock the vehicle while on the lift or remove any heavy component from vehicle that may cause excessive
weight shift.
DO NOT lower the vehicle until people, materials, and tools are clear
ALWAYS INSURE that the safeties are engaged and lowered on to the safety ladders before any attempt is made to work on
or near vehicle.
Some vehicle maintenance and repair activities may cause the vehicle to shift. Follow the manufacturer’s guidelines
when performing these operations. The use of jack stands or alternate lift points may be required when completing
some repairs.
READ AND UNDERSTAND all safety warning procedures before operating lift.
KEEP HANDS AND FEET CLEAR. Remove hands and feet from any moving parts. Keep feet clear of lift when lowering.
Avoid pinch points.
ONLY TRAINED OPERATORS should operate this lift. All non-trained personnel should be kept away from work area. Never
let non-trained personnel come in contact with, or operate lift.
USE LIFT CORRECTLY. Use lift in the proper manner. Never use lifting adapters other than what is approved by the
manufacturer.
STAY ALERT. Watch what you are doing. Use common sense. Be aware.
CHECK FOR DAMAGED PARTS. Check for alignment of moving parts, breakage of parts or any condition that may affect
its operation. Do not use lift if any component is broken or damaged.
NEVER remove safety related components from the lift. Do not use lift if safety related components are damaged or
missing.
When the lift is being lowered, make sure everyone is standing at least six feet away.
Be sure there are no jacks, tools, equipment, left under the lift before lowering.
31
LIFT WILL NOT RAISE
POSSIBLE CAUSE
1. Air in oil, (1,2,8,13)
2. Cylinder binding, (9)
3. Cylinder leaks internally, (9)
4. Motor run backward under pressure, (11)
5. Lowering valve leaks, (3,4,6,10,11)
6. Motor runs backwards, (7,14,11)
7. Pump damaged, (10,11)
8. Pump won’t prime, (1,8,13,14,3,12,10,11)
9. Relief valve leaks, (10,11)
10. Voltage to motor incorrect, (7,14,11)
REMEDY INSTRUCTION
1. Check for proper oil level. . . . . . . . . . . . . . . . . . . . . . . . . . The oil level should be up to the bleed screw in the
reservoir with the lift all the way down.
3. Flush- Release valve to get rid of. . . . . . . . . . . . . . . . . . . . . Hold release handle down and start unit allowing it
possible contamination to run for 15 seconds.
6. Check for free movement of release. . . . . . . . . . . . . . . . . . . If handle does not move freely, replace bracket or
handle assembly.
8. Oil seal damaged or cocked . . . . . . . . . . . . . . . . . . . . . . . . .Replace oil seal around pump shaft.
14. Check wall outlet voltages and wiring . . . . . . . . . . . . . . . . . .Make sure unit and wall outlet are wired properly.
32
MOTOR WILL NOT RUN
POSSIBLE CAUSE
1. Fuse blown, (5,2,1,3,4)
2. Limit switch burned out, (1,2,3,4)
3. Microswitch burned out, (1,2,3,4)
4. Motor burned out, (1,2,3,4,6)
5. Voltage to motor incorrect, (2,1,8)
REMEDY INSTRUCTION
1. Check for correct voltage . . . . . . . . . . . . . . . . . . . . . . . . . . .Compare supply voltage with voltage on motor
nametag. Check that the wire is sized correctly.
N.E.C. table 310-12 requires AWG 10 for 25 Amps.
3. Don’t use extension cords . . . . . . . . . . . . . . . . . . . . . . . . . .According to N.E.C. : “ The size of the conductors…
should be such that the voltage drop would not exceed
3% to the farthest outlet for power…” Do not run motor
at 115 VAC – damage to the motor will occur.
8. Check wall outlet voltage and wiring . . . . . . . . . . . . . . . . . . Make sure unit and wall outlet is wired properly. Motor
must run at 208/230 VAC.
POSSIBLE CAUSE
1. Cylinders binding, (1)
2. Release valve clogged, (5,4,2,3)
3. Pressure fitting too long, (6)
REMEDY INSTRUCTION
1. See Installation Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . .Consult Lift Manufacturer.
5. Clean release valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wash release valve in solvent and blow out with air.
6. Replace fitting with short thread lead . . . . . . . . . . . . . . . . . . . Replace fitting with short thread lead.
33
WILL NOT RAISE LOADED LIFT
OSSIBLE CAUSE
1. Air in oil, (1,2,3,4)
2. Cylinder binding, (5)
3. Cylinder leaks internally, (5)
4. Lift overloaded, (6,5)
5. Lowering valve leaks, (7,8,1,5,9)
6. Motor runs backwards, (10,12,9)
7. Pump damaged, (5,9)
8. Pump won’t prime, (1,2,3,4,5,11,9)
9. Relief valve leaks, (8,5,9)
10. Voltage to motor incorrect, (10,12,5)
REMEDY INSTRUCTION
1. Check oil level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The oil level should be up to the bleed screw in the
reservoir [with the lift all the way down.]
6. Check vehicle weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Compare weight of vehicle to weight limit of the lift.
7. Flush release valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hold release handle down and start unit allowing it to
run for 15 seconds.
10. Check motor is wired correctly . . . . . . . . . . . . . . . . . . . . . . .Compare wiring of motor to electrical diagram on
power unit drawing.
12. Check wall outlet voltage and wiring . . . . . . . . . . . . . . . . . . .Make sure unit and wall outlet is wired properly.
34
LIFT WILL NOT STAY UP
OSSIBLE CAUSE
1. Air in oil, (1,2,3)
2. Check valve leaks, (6)
3. Cylinders leak internally, (7)
4. Lowering valve leaks, (4,5,1,7,6)
5. Leaking fittings, (8)
REMEDY INSTRUCTION
1. Check oil level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .The oil level should be up to the bleed screw in the
reservoir with the lift all the way down.
2. Oil seal damaged and cocked . . . . . . . . . . . . . . . . . . . . . . . . Replace oil seal around pump shaft.
4. Flush release valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hold release handle down and start unit allowing it to
run for 15 seconds.
8. Check complete hydraulic system for leaks. . . . . . . . . . . . . . . Tighten all hydraulics fittings and inpects all hoses.
35
36
Runway Parts List
37
38
Crosstube Parts List
Air Valve Parts List
MAINTENENCE RECORDS
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
39
40
OPTIONAL EQUIPMENT
41
For Parts Or Service
Contact:
Tel: 1-805-933-9970
Toll Free: 1-800-253-2363
Fax: 1-805-933-9160
www.bendpak.com
www.rangerproducts.com