Optical Coherence Tomography

3D OCT-2000
3D OCT-2000

The Topcon 3D OCT-2000 System is the first


Spectral Domain OCT system to incorporate
a high resolution fundus camera and a user-
friendly color touch screen display in a compact,
space saving design.

What makes the Topcon 3D OCT-2000 unique:

» Integrated, high resolution (12.3MP) fundus camera

» FastMap™ software enables dynamic viewing of 2D, 3D and fundus images simultaneously

» Embedded touch-screen for quick and easy navigation

» Historic patient data from Stratus® OCT can be easily imported, analyzed and viewed

» Seamless integration with EyeRoute® Image Management System


High Quality Imaging

3D OCT Image
Topcon’s proprietary FastMap software pioneered
the 3D visualization of OCT data, providing another
dimension of clinical information, thereby enhancing
the understanding and illustration of complex
pathologies such as vitreous traction, macular
edema and retina schesis.
» 3D visualization of OCT data
» Illustrates complex pathologies
» Quickly export images and 3D movies for
presentations

Fundus Image
High resolution, non-mydriatic, color fundus
images allow for visualization of conditions which
otherwise would go undetected with OCT tech-
nology, such as disc hemorrhages. The 45 degree
field of view and the availability of stereo photos
provides the ultimate diagnostic insight.
» High resolution 12.3 MP color fundus camera
» Easily capture and view stereo photos
» P inPoint Registration™ of OCT data in the
fundus image

B-scan Image
FastMap software encompasses the latest in noise
reduction algorithms and overlapping scanning
technology to create exquisite B-Scan images,
which are available almost instantaneously. This
greatly reduces chair time for the patient and
enhances office workflow.
» Uses latest in noise reduction algorithoms
» Enhances office workflow
» Customize capture protocols
Deeper Diagnostic Insights

Comprehensive Capturing
Capture images of the fovea and
optic nerve head in one single
scan and high resolution images
of the choroid with automatic
choroid reference mode.

Video Functions
Use single touch control to
review and playback images
and create 2D and 3D videos.

Extended Scanning Depth


Capture high-quality images
of high-myopic and hyperopic
patients with a diopter com-
pensation lens and an extended
scanning depth of 2.3 mm.

Compare Function
Allows you to visualize serial
exams or view both eyes side
by side.
Deeper Diagnostic Insights

FastMap Software
Topcon’s proprietary FastMap software ensures consistent,
high quality images. Using enhanced 3D registration
technology, FastMap reduces artifacts which may be
caused by eye movement. This in turn allows for speedy
PinPoint Registration of the OCT data within the fundus
image without sacrificing workflow and preserves image
quality of the vitreo-retinal interface.

In addition, FastMap provides dynamic, simultaneous


viewing of the fundus image, and 2D and 3D OCT data,
and automatically detects ILM, RFNL, IS/OS junction, RPE
and Bruch’s membrane, which can also be modified.

Thickness Measurement Functions


FastMap software incorporates the latest layer detection
algorithms, allowing you to automatically measure total
retinal thickness, RNFL or compare against your legacy
Stratus measurements. Manual adjustment of all measure-
ment grids combined with auto and manual registration of
serial exams gives you the highest level of confidence in
retinal and RFNL thickness measurements.

Mosaic Function
Create panoramic views from the macula to the optic disc.
User-Friendly Design

Easy Image Capturing

» Auto focus

» Auto z-off-set

» Auto polarization

»A
 uto fundus capture

» Auto small pupil

Ease of use was the primary objective in the design of the 3D OCT-2000. Combining a fully intuitive,
automated image acquisition process (focus, z-offset, polarization, fundus capture, small pupil) with
Topcon’s user friendly, ergonomic camera design, makes the capture of high quality images quick and
easy for almost anyone.

RNFL Tren
d Analysi
s OU 3D
ID : worflow OCT-2000

Gender 2 Name : pati


:
Age : ent 2 Print Date
: 2010/01/1
OD(R) Ethnicity
: 5
Scan Patte
rn : 3D(6m
Image Qual m x 6mm

Comprehensive Reports
ity:83 - 512 x 128)
1/8/2009
Base Line
1/8/2009 OS(L)
Image Qual
ity:68

Image Qual
ity:82

The auto report generation tool in the 3D OCT-


1/8/2010
Follow up1
1/8/2010
Image Qual
ity:84

2000 saves valuable technician time. The added


Follow up2

Image Qual
ity:90
1/6/2011

flexibility to electronically edit and annotate reports


Latest
1/6/2011
Image Qual
ity:86

Shadow
Gram
RNFL Thickn
ess
Photo

allows for paperless reporting and enables integra-


1.14 mm 2
Disc Area
Change 1.27 mm 2
in RNFL
Thicknes
s

tion with image management and EMR systems.


Disc Param
eters
C/D Area
Cup Vol. RNFL Thickn
Ratio Cup Area
(mm 3) ess Ave.
(mm 2) Inferior
0.42 Superior
0.36 (um) Total
0.43 (+0.01 0.86 (um) RNFL Thickn
) 0.35 (-0.01 (um) ess Ave.
140 Total
) 0.86 ( 97 Superior
0.00 ) 145 104 (um) Disc Param
0.42 ( 0.00 ( +5 ) (um) Inferior eters
100 ( +3 Base Line Cup Area
) 0.35 (-0.01 ) 106 ( 102 (um) Cup Vol.
) 0.87 (+0.01 +2 ) Follow 120 (mm 2) C/D Area
) 147 ( up1 107 126 (mm 3)
+7 ) 104 Follow up2 ( +5 ) Ratio
( +7 ) 128 ( +8 1.12
106 ( +2 ) 119 ( 0.20
) Latest -7 ) 1.16 0.50
110 ( +8 (+0.04 ) 0.38
(+0.18 ) 0.54
Trend Anal ) 138 (
+18 ) 124 (+0.04 )
ysis ( -2 )
1.14 (+0.02
) 0.34 (+0.14
) 0.50 (
0.00 )

Dotted lines
are exten
ded each
linear regre
ssion line
simply, whic
h do not
mean pred
iction in
the futur
e.
Integration and Connectivity

EyeRoute On Board (optional) Legacy Data Compatibility


Images captured with the 3D OCT-2000 can The 3D OCT-2000 ensures full backwards data
be accessed virtually anytime, anywhere – on a compatibility. In addition to 3D OCT-1000 images,
remote computer, a workstation of even the users can read, view and analyze data previously
iPhone® with optional EyeRoute On Board soft- captured on a Stratus System.
ware. EyeRoute enables images to be viewed,
compared, organized and shared with other Review Software
Topcon and non-Topcon instruments. It also allows Users can also utilize the review software, which is
for the import of FA, Red Free, FAF and ICG provided with the 3D OCT-2000 upon request.
images from separate mydriatic camera systems,
which can be registered to the OCT image with
FastMap software.
Specifications

Specifications

Field Angle 45°


Working Distance 40.7mm
Pupil Diameter ≥ 3.3 mm for Fundus image
Scanning Range 8.2 x 3.0 mm, 6.0 x 6.0 mm, 4.5 x 4.5 mm or 3.0 x 3.0 mm
A Scan speed 27,000 A Scans/sec.
Scan Depth 2.3mm
Horizontal Resolution 20µm
Longitudinal Resolution 5-6µm
Fundus Observation Near IR
Fundus Camera Nikon D90 12.3 MP Color
Fixation Adjustable internal matrix LCD and external fixation device
Diopter Scale Range -13D to +12D (in fundus photography)
Light Source Super luminescence diode (SLD)
Wavelength 840nm
Half Bandwidth: 50nm
Output on cornea ≤ 0.65 mW
Automatic OCT Reference Focus Vitreous and Choroid
Scan Patterns 3D, Cross*, Raster*, Line*, Radial*, Circle* (*available with oversampling,
overlapping)
Power Supply Source voltage : AC 100/110/120/220/230/240V 50-60Hz
Power input : 200VA (normal), 400VA (max)
Dimensions 21.5” (W) x 21” (D) x 23.5” - 25” (H)
Weight 70 lbs
Retinal Layers Identified Macula: ILM, IS/OS, RPE, Bruch’s Membrane
Glaucoma: RNFL

Capture PC and Review Station Specifications

Platform IBM PC/AT compatible


CPU Pentium 4 or higher
Memory 4GB or higher *2GB or higher for review station
OS Microsoft Windows® XP Professional
Hard Disc 500 GB* or higher *80 GB required for Review Station Software
Display SXGA 1280 x 1024 32-bit color
Graphics Board VRAM 256MB or higher *512MB preferred

Acessories

Stratus Database Conversion


Review Station Software Licenses
SQL
AIT-650* *Wheel Chair Accessible
AIT-250* *Wheel Chair Accessible
AIT-16

TOPCON MEDICAL SYSTEMS, INC.


111 Bauer Drive, Oakland, NJ 07436
G: 800.223.1130 | P: 201.599.5100 | F: 201.599.5250 | www.topconmedical.com

©2014 Topcon Medical Systems, Inc..

You might also like