0% found this document useful (0 votes)
38 views1 page

NP7-12 Datasheet

This document provides specifications for the Yuasa NP7-12 Industrial VRLA Battery including its nominal voltage, 20-hour and 10-hour rate capacities, dimensions, terminal type, operating temperature range, storage details, case material, charge voltages, charge and discharge current limits, impedance, design life and approvals.

Uploaded by

rc4424030
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views1 page

NP7-12 Datasheet

This document provides specifications for the Yuasa NP7-12 Industrial VRLA Battery including its nominal voltage, 20-hour and 10-hour rate capacities, dimensions, terminal type, operating temperature range, storage details, case material, charge voltages, charge and discharge current limits, impedance, design life and approvals.

Uploaded by

rc4424030
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Yuasa Technical Data Sheet

Yuasa NP7-12 Industrial VRLA Battery

Specifications
Nominal voltage (V) 12
20-hr rate capacity to 1.75v per cell at 20°C (Ah) 7
10-hr rate Capacity to 1.75v per cell at 20°C (Ah) 6.4
20-hr rate Capacity to 1.75V/Cell at 20°C (Ah) 7
Dimensions
Length (mm) 151 (±1)
Width (mm) 65 (±1)
Height over terminals (mm) 97.5 (±2)
Mass (kg) 2.2
Terminal Type
FASTON - Quickfit / release (JST where stated) 4.75
Operating Temperature Range
Storage (in fully charged condition) -20°C to +60°C
Charge -15°C to +50°C
Discharge -20°C to +60°C
Storage
Capacity loss per month at 20°C (% approx.) 3
Layout
Case Material
Standard ABS (UL94:HB)
FR version available UL94:V0
Charge Voltage
Float charge voltage at 20°C (V)/Block 13.65 (±1%)
Float charge voltage at 20°C (V)/Cell 2.275 (±1%)
Float Chg voltage tmp correction factor from std -3
20°C (mV)
Cyclic (or Boost) charge Voltage at 20°C (V)/Block 14.5 (±3%)
Cyclic (or Boost) charge Voltage at 20°C (V)/Cell 2.42 (±3%)
Cyclic Chg voltage tmp correction factor from std -4
20°C (mV)
3rd Party Certifications
Charge Current ISO9001 - Quality Management Systems
Float charge current limit (A) No limit
Cyclic (or Boost) charge current limit (A) 1.75
Maximum Discharge Current
1 second (A) 210
1 minute (A) 48
Impedance Safety
Measured at 1 kHz (mΩ) 23
Installation
Design Life & Approvals Can be installed and operated in any orientation except
EUROBAT Classification: Standard Commercial 3 to 5 years permanently inverted.
Yuasa design life at 20°C (yrs) up to 5 Handles
Batteries must not be suspended by their handles (where
fitted).
Vent valves
Each cell is fitted with a low pressure release valve to allow
gasses to escape and then reseal.
Gas release
VRLA batteries release hydrogen gas which can form
explosive mixtures in the air. Do not place inside a sealed
container.
Recycling
YUASA’s VRLA batteries must be recycled at the end of life in
accordance with local and national laws and regulations.

Data Sheet generated on 09/05/2023 – E&OE

The world's leading battery manufacturer www.yuasaeurope.com

You might also like