The document describes the Agilent 7100 Capillary Electrophoresis System. It provides details on the system's features such as its sensitivity, productivity, and minimal footprint. Application areas where CE can be used are also listed, along with the system's benefits such as analytical performance, flexibility, and reliability.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
85 views2 pages
7100 CE Datasheet
The document describes the Agilent 7100 Capillary Electrophoresis System. It provides details on the system's features such as its sensitivity, productivity, and minimal footprint. Application areas where CE can be used are also listed, along with the system's benefits such as analytical performance, flexibility, and reliability.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2
Agilent 7100 Capillary
Electrophoresis System Highest sensitivity. Highest productivity. Minimal footprint.
Capillary Electrophoresis (CE) offers
fast separations with exceptional effi- ciency and resolution for analytical challenges that often can only be met with difficulty by LC. Used in stand- alone mode, as the separations com- ponent of a CE/MS, or as a comple- mentary, orthogonal technology to LC, the Agilent 7100 CE system brings Features unprecedented HPLC-like sensitivity • Most sensitive CE system on the market to a wide range of analytical • Replenishment system allows high throughput and unattended operation challenges. In addition, CE offers the • Easy maintenance and automated instrument diagnostics advantage that several separation • Plug & play connectivity to all Agilent MS systems modes can be run on a single instru- • Easy method setup data analysis ment. This makes CE a very versatile • Regulatory compliance tools technique for a broad range of appli- • Comprehensive offering of accessories and consumables cations and separation challenges. • Partner solutions for LIF and electrochemical detection
Application Areas Benefits
CE is used to separate, identify, quantify • Best in class analytical performance and fractionate compounds in: • Broadest selection of detectors in the industry • Environmental analysis • Legendary Agilent reliability • Food safety • Reverse-compatible with the Agilent HPCE • Increased uptime • Forensics • Flexible separation modes including capillary electrochromatography • Pharmaceutical discovery, • CE-MS support from the leading vendor with the longest CE-MS experience development, and QA/QC • Broad application coverage • Life Sciences • Complete solution for charged sample analysis Specifications Agilent 7100 Capillary Electrophoresis System
Pressure system Raw data channels
Programmable with –100 to +100 mbar on inlet Detector signals and spectrum, voltage, current, leak current, Flushing with 1 bar or with high pressure 2–12 bar power, cassette temperature, pressure, lamp voltage and detector Vial pressurization with high pressure 2–12 bar on inlet temperature and/or outlet Diagnostic functions Injection modes RFID tag for lamp, early maintenance feedback, supported by Self correcting injection system with injection from inlet or outlet Agilent Lab Advisor software with integrated diagnosis test suite Programmable range: up to 10,000 seconds Pressure: –100 to +100 mbar Safety features Electrokinetic: –30 to +30 kV Current leak detection: low current limit Liquid leak sensor Autosampler/ fraction collector Safety sensors at door and cover disabling high voltage 50-position carousel Vial sensor All vials are randomly accessible from inlet or outlet end of capillary. Environment Temperature control with external waterbath with vial Temperature: 5–40 °C temperature from 10–40 °C. Humidity: up to 80 % rel. humidity at 31 °C (non-condensing) (Non-condensing conditions, minimum waterbath System control temperature +1 °C). Operating with graphical user interface under Windows XP (SP3) Replenishment Time programmable parameters: voltage, current, power, Satellite station for refilling of inlet or outlet buffer vials with polarity, pressure, inlet and outlet vial, capillary temperature, fresh buffer for automatic, continuous operation. Selectable pre and post-run conditioning with pressure and/or voltage, buffer levelling. Replenishment, fraction collection** Vials CE specific software 100 µL (polypropylene or glas) with resealing snap caps Mobility report, time corrected areas, pI calibration and bio 1 mL (polypropylene) with resealing snap caps polymer size calibration. 2 mL (glas) with resealing snap caps Physical Specifications Capillary cassette High-speed forced-air cooler with Peltier element Dimensions Interfaces Temperature range: 10 °C below ambient, up to 60 °C Width: 35 cm LAN, CAN, RS232, remote (min. 10 °C cassette temperature) Height: 59 cm control, analog in (1V, 20 bit, Minimum total capillary length: 33 cm Depth: 51 cm integrated A/D converter), Capillary compatibility 365 µm o.d. Weight: 35 kg analog out Detector Power requirements Electrophoresis power Real time UV-Visible diode-array detector (190–600 nm) Line voltage: 100-240 V, Voltage range: setable Temperature controlled max. 300 W 0 to ± 30 kV supply Wavelength accuracy: 1 nm Line frequency: 50-60 Hz Current: setable 0 - 300 µA Response time: 0.025 to 10 s Power: setable 0 - 6 W operation Light source: prealigned deuterium or high brightness lamp under constant voltage, current Signals: up to eight signals simultaneously, full spectral acquisition or power with Agilent ChemStation Sensitivity: 1 µM 4-hydroxy-aceto-phenon injected at * typical value 50 mbar • 5 sec, 3 x 50 µm bubble cell capillary, **upgradeable signal/noise >6* (50 mM borate buffer pH 9.3, 25 kV) Baseline noise: <20 µAU (at 2 sec response time)* Linear dynamic range: 1x104 (3 x 50 µm bubble cell capillary)* www.agilent.com/chem/ce