DAIKIN ROOM AIR CONDITIONER

OPERATION MANUAL

Français
Español

MODELS
FTXS09LVJU
FTXS12LVJU
CTXS07LVJU

00_CV_3P297290-1C.indd 1 10/29/2015 13:30:23


Feature

For your comfort and energy


saving

INTELLIGENT EYE
The INTELLIGENT EYE sensor detects the human movement in
a room. If no one is room for more than 20 minutes, the
operation automatically changes to energy saving operation.
Page 15

WEEKLY TIMER
Up to 4 timer settings can be saved for each day of the week
according to your family’s life style. The WEEKLY TIMER allows
you to set on/off time and the desired temperature. Page 22

Other functions
COMFORT AIRFLOW OUTDOOR UNIT QUIET
The airflow direction will be in upward mode OUTDOOR UNIT QUIET operation
while in COOL operation, in downward mode lowers the noise level of the outdoor
while in HEAT operation. This function will unit. This function is useful in
prevent cold or warm air from directly blowing consideration of your neighbors.
on your body. Page 15 Page 18

1
01_EN_3P297290-1C.indd 1 12/8/2015 13:27:24
Contents

English
„ Read before Operation
Safety Considerations .......................................... 3
Names of Parts .................................................... 5
Preparation before Operation .............................. 9

„ Operation
AUTO · DRY · COOL · HEAT · FAN
Operation ................................................ 11

Adjusting the Airflow Direction


and Rate ................................................. 13

COMFORT AIRFLOW /
INTELLIGENT EYE Operation ................ 15

POWERFUL Operation ........................... 17

OUTDOOR UNIT QUIET


Operation ................................................ 18

ECONO Operation .................................. 19

OFF TIMER Operation ............................ 20

ON TIMER Operation .............................. 21

WEEKLY TIMER Operation..................... 22

„ Multi Connection
Note for Multi System ....................................... 28

„ Care
ECONO
This function enables efficient operation
Care and Cleaning ............................................ 30
by limiting the maximum power
consumption. It is useful when using the
air conditioner and other electrical „ Troubleshooting
e 18 devices simultaneously. Page 19
Troubleshooting ................................................ 35
2
01_EN_3P297290-1C.indd 2 12/8/2015 13:27:26
Safety Considerations
Read these Safety Considerations for Operations carefully WARNING
before operating an air conditioner or heat pump.
Make sure that the unit operates properly during the startup • Contact your dealer for repair and maintenance.
operation. Instruct the user on how to operate and maintain the Improper repair and maintenance may result in water
unit. leakage, electric shock, and fire. Only use accessories
Inform users that they should store this operation manual with made by Daikin that are specifically designed for use with
the installation manual for future reference. the equipment and have them installed by a professional.
Meanings of DANGER, WARNING, CAUTION, and NOTE • Contact your dealer to move and reinstall the air conditioner
Symbols: or heat pump. Incomplete installation may result in water
leakage, electric shock, and fire.
DANGER ........... Indicates an imminently hazardous • Never let the indoor unit or the remote controller get wet.
situation which, if not avoided, will Water can cause an electric shock or a fire.
result in death or serious injury. • Never use flammable spray such as hair spray, lacquer, or
WARNING ......... Indicates a potentially hazardous paint near the unit. Flammable spray may cause a fire.
situation which, if not avoided, could • When a fuse blows out, never replace it with one of
result in death or serious injury. incorrect ampere ratings or different wires. Always replace
CAUTION .......... Indicates a potentially hazardous any blown fuse with a fuse of the same specification.
situation which, if not avoided, may • Never remove the fan guard of the unit. A fan rotating at
result in minor or moderate injury. high speed without the fan guard is very dangerous.
It may also be used to alert against • Never inspect or service the unit by yourself. Contact a
unsafe practices. qualified service person to perform this work.
NOTE ................ Indicates situations that may result • Turn off all electrical power before doing any maintenance
in equipment or property-damage to avoid the risk of serious electric shock; never sprinkle or
accidents only. spill water or liquids on the unit.
• Do not touch the switch with wet fingers. Touching a switch
DANGER with wet fingers can cause electric shock.
• Do not allow children to play on or around the unit to
• Do not install the unit in an area where flammable materials prevent injury.
are present due to risk of explosion resulting in serious
• The heat exchanger fins are sharp enough to cut. To avoid
injury or death.
injury wear gloves or cover the fins while working around
• Any abnormalities in the operation of the air conditioner or them.
heat pump, such as smoke or fire, could result in severe
• Do not put a finger or other objects into the air inlet or air
injury or death. Turn off the power and contact your dealer
outlet. The fan is rotating at high speed and will cause injury.
immediately.
• Check the unit foundation for damage on a continuous
• Refrigerant gas may produce toxic gas if it comes into contact
basis, especially if it has been in use for a long time. If left in
with fire, such as from a fan heater, stove, or cooking device.
a damaged condition the unit may fall and cause injury.
Exposure to this gas could cause severe injury or death.
• Placing a flower vase or other containers with water or
• For refrigerant leakage, consult your dealer.
other liquids on the unit could cause a shock or fire if a spill
Refrigerant gas is heavier than air and replaces oxygen.
occurs.
A massive leak could lead to oxygen depletion, especially
in basements, and an asphyxiation hazard could occur • Do not touch the air outlet or horizontal blades while the
leading to serious injury or death. swing flap is in operation because fingers could get caught
and injured.
• If equipment utilizing a burner is used in the same room
as the air conditioner or heat pump, there is the danger • Never touch the internal parts of the controller. Do not
of oxygen deficiency which could lead to an asphyxiation remove the front panel because some parts inside are
hazard resulting in serious injury or death. Be sure to dangerous to touch. To check and adjust internal parts,
ventilate the room sufficiently to avoid this hazard. contact your dealer.
• Safely dispose of the packing materials. Packing materials,
such as nails and other metal or wooden parts, may cause CAUTION
stabs or other injuries.
• Do not use the air conditioner or heat pump for any other
• Tear apart and throw away plastic packaging bags so that purposes other than comfort cooling or heating.
children will not play with them. Children playing with plastic Do not use the unit for cooling precision instruments, food,
bags face the danger of death by suffocation. plants, animals or works of art.

3
01_EN_3P297290-1C.indd 3 12/8/2015 13:27:26
English
• Do not place items under the indoor unit as they may be • Dismantling of the unit, disposal of the refrigerant, oil, and
damaged by condensates that may form if the humidity is additional parts, should be done in accordance with the
above 80% or if the drain outlet gets blocked. relevant local, state, and national regulations.
• Before cleaning, stop the operation of the unit by turning the • Operate the air conditioner or heat pump in a sufficiently
power off or by pulling the supply cord out from its receptacle. ventilated area and not surrounded by obstacles. Do not
Otherwise, an electric shock and injury may result. use the air conditioner or heat pump in the following places.
• Do not wash the air conditioner or heat pump with a. Places with a mist of mineral oil, such as cutting oil.
excessive water. An electric shock or fire may result. b. Locations such as coastal areas where there is a lot of
• Avoid placing the controller in a spot splashed with water. salt in the air.
Water entering the controller may cause an electric shock c. Locations such as hot springs where there is a lot of
or damage the internal electronic parts. sulfur in the air.
• Do not operate the air conditioner or heat pump when using d. Locations such as factories where the power voltage
a room-fumigation type of insecticide. varies a lot.
Failure to observe this could cause the chemicals to be e. In cars, boats, and other vehicles.
deposited in the unit and can endanger the health of those f. Locations such as kitchens where oil may splatter or
who are hypersensitive to chemicals. where there is steam in the air.
• Do not turn off the power immediately after stopping g. Locations where equipment produces electromagnetic
operation. Always wait for at least 5 minutes before turning waves.
off the power. Otherwise, water leakage may occur. h. Places with an acid or alkaline mist.
• The appliance is not intended for use by young children or i. Places where fallen leaves can accumulate or where
infirm persons without supervision. weeds can grow.
• The remote controller should be kept away from children so • Take snow protection measures. Contact your dealer for the
they cannot play with it. details of snow protection measures, such as the use of a
snow protection hood.
• Consult with the installation contractor for cleaning.
• Do not attempt to do electrical work or grounding work
• Incorrect cleaning of the inside of the air conditioner or heat
unless you are licensed to do so. Consult with your dealer
pump could make the plastics parts break and cause water
for electrical work and grounding work.
leakage or electric shock.
• Pay attention to operating sound. Be sure to use the
• Do not touch the air inlet or aluminum fin of the air
following places:
conditioner or heat pump as they can cut and cause injury.
a. Places that can sufficiently withstand the weight of the
• Do not place objects in direct proximity of the outdoor unit. air conditioner or heat pump yet can suppress the
Do not let leaves and other debris accumulate around the
operating sound and vibration.
unit. Leaves are a hotbed for small animals which can enter
b. Places where warm air from the air outlet of the outdoor
the unit. Once inside the unit, animals can cause the unit
unit or the operating sound of the outdoor unit does not
to malfunction, and cause smoke or fire when they make
contact with electrical parts. annoy neighbors.
• Make sure that there are no obstacles close to the outdoor
unit. Obstacles close to the outdoor unit may drop the
NOTE
performance of the outdoor unit or increase the operating
• Never press the button of the remote controller with a hard, sound of the outdoor unit.
pointed object. The remote controller may be damaged. • Consult your dealer if the air conditioner or heat pump in
• Never pull or twist the electric wire of the remote controller. operation generates unusual noise.
It may cause the unit to malfunction. • Make sure that the drainpipe is installed properly to drain
• Do not place appliances that produce open flames in water. If no water is discharged from the drainpipe while
places that are exposed to the airflow of the unit or under the air conditioner or heat pump is in the cooling mode,
the indoor unit. It may cause incomplete combustion or the drainpipe may be clogged with dust or dirt and water
deformation of the unit due to the heat. leakage from the indoor unit may occur. Stop operating the
air conditioner or heat pump and contact your dealer.
• Do not expose the controller to direct sunlight. The LCD display
can become discolored and may fail to display the data.
• Do not wipe the controller operation panel with benzene,
thinner, chemical dust cloth, etc. The panel may get
discolored or the coating can peel off. If it is heavily dirty, soak
a cloth in water-diluted neutral detergent, squeeze it well and
wipe the panel clean. Then wipe it with another dry cloth.

4
01_EN_3P297290-1C.indd 4 12/8/2015 13:27:26
Names of Parts
Indoor Unit
Front panel Air inlet

Panel tab

INTELLIGENT EYE
sensor
• It detects the movements of
people and automatically
switches between normal
Model name operation and energy saving
plate operation. Page 15

Air outlet

Louvers (vertical blades)


• The louvers are inside of the air
outlet. Page 13
Room temperature
Flaps sensor
(horizontal blades) Page 13
• It detects the air temperature
around the unit.

Display
OPERATION lamp (green)
Signal receiver
• It receives signals from the remote
controller. TIMER lamp (yellow)
• When the unit receives a signal, you Page 20,21
will hear a beep sound.
Case Sound type
Operation start beep-beep
INTELLIGENT EYE lamp
Setting changed beep (green) Page 15,16
Operation stop long beep

Indoor unit ON/OFF switch


• Press this switch once to start operation.
Press once again to stop it.
• The operation mode refer to the following table.
Mode Temperature setting Airflow rate
AUTO 77°F (25°C) AUTO

• This switch is useful when the remote controller is missing.

5
01_EN_3P297290-1C.indd 5 12/8/2015 13:27:27
English
„ Open the front panel

Air filter

Titanium apatite
photocatalytic
air-purifying filter
Outdoor Unit
• Appearance of the outdoor unit may differ from some models.

Air inlet Outdoor temperature


(back and side) sensor (back)

Drain hose
Ground terminal
• Inside this cover.

Air outlet Model name plate


Refrigerant piping and
inter-unit wiring

6
01_EN_3P297290-1C.indd 6 12/8/2015 13:27:27
Names of Parts
Remote Controller

Signal transmitter

Display (LCD)
• Displays the current settings.
Receiver (In this illustration, each section is
shown with all its displays on for the
purpose of explanation.)
• To use the remote controller, aim the
transmitter at the indoor unit. If there
is anything to block signals between
the unit and the remote controller,
such as a curtain, the unit will not
operate. TEMPERATURE
• Do not drop the remote controller. Do
not get it wet.
adjustment buttons
• The maximum distance for • Changes the temperature setting.
communication is approximately 23ft Page 12
(7m).

ON/OFF button
FAN setting button • Press this button once to start
• Selects the airflow rate setting. operation.
Page 14 Press once again to stop it. Page 11

POWERFUL button Front cover


• POWERFUL operation. Page 17 • Open the front cover. Page 8

<ARC452A21>

7
01_EN_3P297290-1C.indd 7 12/8/2015 13:27:27
English
„ Open the front cover

MODE selector button ECONO button


• Selects the operation mode. • ECONO operation. Page 19
(AUTO/DRY/COOL/HEAT/
FAN) Page 11

SWING button
• Adjusting the airflow direction.
Page 13

QUIET button COMFORT/SENSOR


• OUTDOOR UNIT QUIET button
operation. Page 18 • COMFORT AIRFLOW and
INTELLIGENT EYE operation.
Page 15,16

OFF TIMER button


Page 20
: WEEKLY button
: PROGRAM button
: COPY button
: BACK button
TIMER CANCEL
button : NEXT button
• Cancels the timer setting. • WEEKLY TIMER operation.
Page 20,21 Page 22
• It cannot be used for the
WEEKLY TIMER operation.

ON TIMER button
Page 21
SELECT button
• Changes the ON/OFF TIMER
and WEEKLY TIMER settings.
Page 20,21,22

CLOCK button Page 10

8
01_EN_3P297290-1C.indd 8 12/8/2015 13:27:28
Preparation before Operation
2 „ To set the batteries
Position + and
– correctly!
1. Slide the front cover to take it off.
3
1
2. Set two dry batteries AAA.LR03 (alkaline).
3. Set the front cover as before.
„ To fix the remote controller holder to a wall
Remote controller
1. Choose a place from where the signals reach
the unit.
2. Fix the holder to a wall, a pillar, etc. with the
screws supplied with the holder.
Screws 3. Place the remote controller in the remote
controller holder.
Remote
controller holder
„ Celsius/Fahrenheit display switch
• The Celsius or Fahrenheit display is selectable with the following buttons.

Press and simultaneously for


5 seconds.
• The temperature will be displayed in Fahrenheit if it is presently displayed in Celsius,
and vice versa.
NOTE
„ Notes on batteries
• When replacing the batteries, use batteries of the same type, and replace both batteries at the same time.
• When the system is not used for a long time, take the batteries out.
• The batteries will last for approximately 1 year. If the remote controller display begins to fade and the degradation of reception performance
occurs within a year, however, replace both batteries with new, size AAA.LR03 (alkaline).
• The attached batteries are provided for the initial use of the system.
The usable period of the batteries may be short depending on the manufactured date of the air conditioner.
„ Notes on remote controller
• Never expose the remote controller to direct sunlight.
• Dust on the signal transmitter or receiver will reduce the sensitivity. Wipe off dust with a soft cloth.
• Signal communication may be disabled if an electronic-starter-type fluorescent lamp (such as inverter-type lamps) is in the room. Consult the
shop if that is the case.
• If the remote controller signals happen to operate another appliance, move that appliance somewhere else, or consult the service shop.
„ Celsius/Fahrenheit display change function of remote controller
• The set temperature may increase when the display is changed to Celsius from Fahrenheit, because a fraction of 0.5°C is rounded up.
• Example: A set temperature of 65°F (equivalent to 18.5°C) will be converted into 19°C.
When the display is changed to Fahrenheit again, the set temperature will be converted into 66°F (equivalent to 19°C) instead of the
original set temperature (65°F) but a set temperature of 66°F (equivalent to 19°C) will be converted into 19°C with no temperature change.
• A reception sound will go off for the transmission of set temperature to the indoor unit at the time of setting the Celsius/Fahrenheit display change function.

9
01_EN_3P297290-1C.indd 9 12/8/2015 13:27:28
English
„ Turn the breaker on
• After the power is turned on, the flaps of the indoor unit open and close once to set
the reference position.

„ To set the clock

1. Press .
“ ” is displayed.
“ ” and “ ” blink.

2. Press to set the current day of the week.

3. Press .
“ ” blinks.

4. Press to set the clock to the present time.


• Holding down or rapidly increases or decreases the time display.

5. Press .
• Point the remote controller at the indoor unit when pressing the buttons.

“ ” blinks.

10
01_EN_3P297290-1C.indd 10 12/8/2015 13:27:29
AUTO · DRY · COOL · HEAT ·
FAN Operation
The air conditioner operates with the operation mode of your choice.
From the next time on, the air conditioner will operate with the same operation mode.

„ To start operation

1. Press and select an operation mode.


• Each pressing of the button advances the mode setting in sequence.

AUTO DRY COOL HEAT FAN

2. Press .
•“ ” is displayed on the LCD.
• The OPERATION lamp lights green.

Display

„ To stop operation

Press again.
•“ ” is no longer displayed on the LCD.
• The OPERATION lamp goes off.

NOTE
MODE Notes on each operation mode
• Since this air conditioner heats the room by taking heat from outdoor air to indoors, the heating capacity becomes smaller in lower outdoor
temperatures. If the heating effect is insufficient, it is recommended to use another heating appliance in combination with the air conditioner.
• The heat pump system heats the room by circulating hot air around all parts of the room. After the start of HEAT operation, it takes
HEAT
some time before the room gets warmer.
• In HEAT operation, frost may occur on the outdoor unit and lower the heating capacity. In that case, the system switches into
defrosting operation to take away the frost.
• During defrosting operation, hot air does not flow out of indoor unit.
• This air conditioner cools the room by releasing the heat in the room outside. Therefore, the cooling performance of the air
COOL
conditioner may be degraded if the outdoor temperature is high.
• The computer chip works to rid the room of humidity while maintaining the temperature as much as possible. It automatically
DRY
controls temperature and airflow rate, so manual adjustment of these functions is unavailable.
• In AUTO operation, the system selects an appropriate operation mode (COOL or HEAT) based on the room and outside
AUTO temperatures and starts the operation.
• The system automatically reselects setting at a regular interval to bring the room temperature to user-setting level.
FAN • This mode is valid for fan only.

11
01_EN_3P297290-1C.indd 11 12/8/2015 13:27:29
English
„ To change the temperature setting

Press or .
• The displayed items on the LCD will change whenever either one of the buttons is
pressed.
COOL operation HEAT operation AUTO operation DRY or FAN operation
64-90°F 50-86°F 64-86°F
(18-32°C) (10-30°C) (18-30°C) The temperature setting
Press to raise the temperature and press to lower the cannot be changed.
temperature.

„ Operating conditions
„ Recommended temperature setting
• For cooling: 78-82°F (26-28°C)
• For heating: 68-75°F (20-24°C)
„ Tips for saving energy
• Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
• Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
• Clogged air filters cause inefficient operation and waste energy. Clean them once in about every 2 weeks. Page 32
„ Notes on the operating conditions
• The air conditioner always consumes a small amount of electricity even while it is not operating.
• If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker off.
• Use the air conditioner in the following conditions.
MODE Operating conditions If operation is continued out of this range
Outdoor temperature: 50-115°F (10-46°C) • A safety device may work to stop the operation.
COOL Indoor temperature: 64-90°F (18-32°C) (In multi system, it may work to stop the operation of the outdoor unit only.)
Indoor humidity: 80% max. • Condensation may occur on the indoor unit and drip.
Outdoor temperature: [2/3MXL]: –13-75°F (–25-24°C) • A safety device may work to stop the operation.
HEAT [Other models]: 5-75°F (–15-24°C)
Indoor temperature: 50-86°F (10-30°C)
Outdoor temperature: 50-115°F (10-46°C) • A safety device may work to stop the operation.
DRY Indoor temperature: 64-90°F (18-32°C) • Condensation may occur on the indoor unit and drip.
Indoor humidity: 80% max.

• Operation outside this humidity or temperature range may cause a safety device to disable the system.

12
01_EN_3P297290-1C.indd 12 12/8/2015 13:27:30
Adjusting the Airflow Direction
and Rate
You can adjust the airflow direction to increase your comfort.

„ To start auto swing


Upper and lower airflow direction

Press .
• “ ” is displayed on the LCD.
• The flaps (horizontal blades) will begin to swing.

Right and left airflow direction

Press .
•“ ” is displayed on the LCD.
• The louvers (vertical blades) will begin to swing.

The 3-D airflow direction

Press and .
• “ ” and “ ” are displayed on the LCD.
• The flaps and louvers move in turn.
• To cancel 3-D airflow, press either or again.
The flaps or louvers will stop moving.

„ To set the flaps or louvers at the desired position


• This function is effective while flaps or louvers are in auto swing mode.

Press and when the flaps or


louvers reach the desired position.
• In the 3-D airflow, the flaps and louvers move in turn.
• “ ” or “ ” disappears from the LCD.

13
01_EN_3P297290-1C.indd 13 12/8/2015 13:27:30
English
„ To adjust the airflow rate setting

Press .
• Each pressing of advances the airflow rate setting in sequence.

Auto Indoor unit quiet Low Middle low

High Middle high Middle

• When the airflow is set to “ ”, indoor unit quiet operation will start and the noise
from the unit will become quieter.
• In indoor unit quiet operation, the airflow rate is set to a weak level.
• In DRY operation, the airflow rate setting cannot be changed.

NOTE
„ Notes on the angles of the flaps
• The flaps swinging range depends on the operation. (See the figure.)
COOL and DRY operation HEAT operation FAN operation

Stop operation
COMFORT 8°
AIRFLOW 30° Upper limit 8°
15°
Upper limit 45° Upper limit 70° 80°
Lower limit Lower limit
Stop operation 80° Lower limit Stop operation
COMFORT AIRFLOW

„ Note on 3-D airflow


• Using 3-D airflow circulates cold air, which tends to collected at the bottom of the room, and hot air, which tends to collect near the ceiling,
throughout the room, preventing areas of cold and hot developing.
„ Note on airflow rate setting
• At smaller airflow rates, the cooling (heating) effect is also smaller.

CAUTION
• Always use a remote controller to adjust the angles of the flaps and louvers.
− If you attempt to move the flaps and louvers forcibly by hand when they are swinging, the mechanism may be damaged.
− Inside the air outlet, a fan is rotating at a high speed.

14
01_EN_3P297290-1C.indd 14 12/8/2015 13:27:31
COMFORT AIRFLOW /
INTELLIGENT EYE Operation
„ COMFORT AIRFLOW operation
The flow of air will be in the upward direction while in COOL operation and in the downward direction while in
HEAT operation, which will provide a comfortable wind that will not come in direct contact with people.

COOL operation HEAT operation

„ INTELLIGENT EYE operation


“INTELLIGENT EYE” is the infrared sensor which detects the human movement.
If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving
operation.
[Example]

When someone is in When no one is in the Someone is back in the


the room room room
„ Normal operation „ 20 minutes after, start „ Back to normal
• The air conditioner is in energy saving operation.
normal operation while the operation. • The air conditioner will
sensor is detecting the return to normal operation
• The set temperature is
movement of people. when the sensor detects the
shifted in ±3.6°F (±2°C)
steps. movement of people again.

INTELLIGENT EYE operation is useful for energy saving


„ Energy saving operation
• If no presence is detected in the room for 20 minutes, the energy saving operation will start, and the INTELLIGENT EYE lamp goes off.
If human movement is detected again, the INTELLIGENT EYE lamp lights up and energy saving operation terminates.
• This operation changes the temperature –3.6°F (–2°C) in HEAT / +3.6°F (+2°C) in COOL / +3.6°F (+2°C) in DRY operation from set temperature.
When the room temperature exceeds 86°F (30°C), the operation changes the temperature +1.8°F (+1°C) in COOL / +1.8°F (+1°C) in DRY
operation from set temperature.
• This operation decreases the airflow rate slightly in FAN mode only.

„ Combination COMFORT AIRFLOW and INTELLIGENT EYE operation


The air conditioner can go into operation with the COMFORT AIRFLOW and INTELLIGENT EYE functions
combined.

15
01_EN_3P297290-1C.indd 15 12/8/2015 13:27:31
English
„ To start operation
Press and select the desired mode.
• Each time the is pressed a different setting option is displayed on the LCD.
• When INTELLIGENT EYE is selected, the INTELLIGENT EYE lamp lights green.

Display

• By selecting “ ” from the following icons, the air conditioner will be in COMFORT
AIRFLOW operation combined with INTELLIGENT EYE operation.

blank
COMFORT INTELLIGENT Combination No Setting
AIRFLOW EYE

• When the flaps (horizontal blades) are swinging, selecting any of the modes above will
cause the flaps (horizontal blades) to stop.

„ To cancel operation
Press and select “blank” on the LCD.
• If the INTELLIGENT EYE operation was being used, the INTELLIGENT EYE lamp goes off.

NOTE
„ Notes on COMFORT AIRFLOW operation
• The position of the flaps will change, preventing air from blowing directly on the occupants of the room.
• POWERFUL operation and COMFORT AIRFLOW operation cannot be used at the same time.
Priority is given to the function of whichever button is pressed last.
• The airflow rate will be set to AUTO. If the upper and lower airflow direction is selected, the COMFORT AIRFLOW function will be canceled.
„ Notes on INTELLIGENT EYE operation
• Application range is as follows.
Vertical angle 90° Horizontal
(Side view) angle 110°
55° 55°
) (Top view)
7m
(7m)
23ft

ft ( 90°
23

• Sensor may not detect moving objects further than 23ft (7m) away. (Check the application range)
• Sensor detection sensitivity changes according to indoor unit location, the speed of passersby, temperature range, etc.
• The sensor also mistakenly detects pets, sunlight, fluttering curtains and light reflected off of mirrors as passersby.
• INTELLIGENT EYE operation will not go on during POWERFUL operation.
• NIGHT SET mode Page 20 will not go on during use of INTELLIGENT EYE operation.

„ Notes on combination of COMFORT AIRFLOW operation and INTELLIGENT EYE operation


• The airflow rate will be set to AUTO. If the upper and lower airflow direction is selected, the COMFORT AIRFLOW operation will be canceled.
Priority is given to the function of whichever button is pressed last.

CAUTION
• Do not place large objects near the sensor.
Also keep heating units or humidifiers outside the sensor’s detection area. This sensor can detect undesirable objects.
• Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.

16
01_EN_3P297290-1C.indd 16 12/8/2015 13:27:32
POWERFUL Operation
POWERFUL operation quickly maximizes the cooling (heating) effect in any
operation mode. You can get the maximum capacity.

„ To start POWERFUL operation

Press during operation.


• POWERFUL operation ends in 20 minutes. Then the system automatically operates
again with the previous settings which were used before POWERFUL operation.
•“ ” is displayed on the LCD.

„ To cancel POWERFUL operation

Press again.
•“ ” is no longer displayed on the LCD.

[Example]

„ Normal operation „ POWERFUL operation „ Back to normal


• When you want to get the • POWERFUL operation will operation
cooling effect quickly, start work for 20 minutes.
the POWERFUL operation.

NOTE
„ Notes on POWERFUL operation
• When using POWERFUL operation, there are some functions which are not available.
• POWERFUL operation cannot be used together with ECONO, COMFORT AIRFLOW or OUTDOOR UNIT QUIET operation.
Priority is given to the function of whichever button is pressed last.

• POWERFUL operation can only be set when the unit is running. Pressing causes the settings to be canceled, and “ ” is no longer
displayed on the LCD.
• POWERFUL operation will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity
demonstrated.
• In COOL, HEAT and AUTO operation
To maximize the cooling (heating) effect, the capacity of outdoor unit increases and the airflow rate becomes fixed at the maximum setting.
The temperature and airflow settings cannot be changed.
• In DRY operation
The temperature setting is lowered by 4.5°F (2.5°C) and the airflow rate is slightly increased.
• In FAN operation
The airflow rate is fixed to the maximum setting.

17
01_EN_3P297290-1C.indd 17 12/8/2015 13:27:32
OUTDOOR UNIT QUIET

English
Operation
OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by
changing the frequency and fan speed on the outdoor unit. This function is
convenient during the night.

„ To start OUTDOOR UNIT QUIET operation

Press .
•“ ” is displayed on the LCD.

„ To cancel OUTDOOR UNIT QUIET operation

Press again.
•“ ” is no longer displayed on the LCD.

[Example] Using the OUTDOOR UNIT QUIET operation during the night.

• The noise level of the outdoor unit will be lower.


This is convenient in consideration of your neighbors.

NOTE
„ Notes on OUTDOOR UNIT QUIET operation
• If using a multi system, the OUTDOOR UNIT QUIET operation will work only when this function is set on all operated indoor units. However, if
using priority room setting, refer to “Note for multi system”. Page 28
• This function is available in COOL, HEAT, and AUTO operation.
This is not available in FAN and DRY operation.
• POWERFUL operation and OUTDOOR UNIT QUIET operation cannot be used at the same time.
Priority is given to the function of whichever button is pressed last.
• Even the operation is stopped using the remote controller or the indoor unit ON/OFF switch when using OUTDOOR UNIT QUIET operation, “ ”
will remain on the remote controller display.
• OUTDOOR UNIT QUIET operation will drop neither the frequency nor fan speed if they have been already dropped low enough.

18
01_EN_3P297290-1C.indd 18 12/8/2015 13:27:33
ECONO Operation
ECONO operation is a function which enables efficient operation by limiting the
maximum power consumption value.
This function is useful for cases in which attention should be paid to ensure a
circuit breaker will not trip when the product runs alongside other appliances.

„ To start ECONO operation

Press during operation.


•“ ” is displayed on the LCD.

„ To cancel ECONO operation

Press again.
•“ ” is no longer displayed on the LCD.

[Example]
Normal operation ECONO operation

• In case the air conditioner and other • The maximum power consumption of the air
appliances which require high power conditioner is limited by using ECONO operation.
consumption are used at same time, a circuit The circuit breaker is unlikely to trip even if the
breaker may trip if the air conditioner operate air conditioner and other appliances are used at
with its maximum capacity. same time.

Running current and • This diagram is a representation for illustrative


power consumption purposes only.
Maximum during The maximum running current and power
Normal normal operation
operation consumption of the air conditioner in ECONO
Maximum during operation vary with the connecting outdoor
ECONO operation
unit.
ECONO
operation

Time
From start up until set temperature is reached

NOTE
„ Notes on ECONO operation
• ECONO operation can only be set when the unit is running. Pressing causes the settings to be canceled, and “ ” is no longer displayed
on the LCD.
• ECONO operation functions in AUTO, COOL, DRY, and HEAT operation.
• POWERFUL and ECONO operation cannot be used at the same time.
Priority is given to the function of whichever button is pressed last.
• If the level of power consumption is already low, ECONO operation will not drop the power consumption.

19
01_EN_3P297290-1C.indd 19 12/8/2015 13:27:33
OFF TIMER Operation

English
Timer functions are useful for automatically switching the air conditioner on or off
at night or in the morning. You can also use OFF TIMER and ON TIMER in
combination.

„ To use OFF TIMER operation


• Check that the clock is correct.
If not, set the clock to the present time. Page 10

1. Press .
“ ” is displayed on the LCD.
“ ” blinks.

•“ ” is no longer displayed on the LCD.

2. Press until the time setting reaches the


point you like.
• Each pressing of either button increases or decreases the time setting by 10 minutes.
Holding down either button changes the time setting rapidly.

3. Press again.
•“ ” and setting time are displayed on the LCD.
• The TIMER lamp lights yellow.

Display

„ To cancel OFF TIMER operation

Press .
•“ ” and setting time are no longer displayed on the LCD.
• “ ” and day of the week are displayed on the LCD.
• The TIMER lamp goes off.

NOTE
„ Notes on TIMER operation
• When TIMER is set, the present time is not displayed.
• Once you set ON/OFF TIMER, the time setting is kept in the memory. The memory is canceled when remote controller batteries are replaced.
• When using the ON/OFF TIMER to start/stop operation, the actual operation start/stop time may differ from the time set. (Maximum of about
10 minutes)
„ NIGHT SET mode
• When the OFF TIMER is set, the air conditioner automatically adjusts the temperature setting (0.9°F (0.5°C) up in COOL, 3.6°F (2.0°C) down in
HEAT) to prevent excessive cooling (heating) for your pleasant sleep.

20
01_EN_3P297290-1C.indd 20 12/8/2015 13:27:34
ON TIMER Operation
„ To use ON TIMER operation
• Check that the clock is correct.
If not, set the clock to the present time. Page 10

1. Press .
“ ” is displayed on the LCD.
“ ” blinks.

•“ ” and day of the week are no longer displayed on the LCD.

2. Press until the time setting reaches the


point you like.
• Each pressing of either button increases or decreases the time setting by 10 minutes.
Holding down either button changes the setting rapidly.

3. Press again.
•“ ” and setting time are displayed on the LCD.
• The TIMER lamp lights yellow.

Display

„ To cancel ON TIMER operation

Press .
•“ ” and setting time are no longer displayed on the LCD.
• “ ” and day of the week are displayed on the LCD.
• The TIMER lamp goes off.

„ To combine ON TIMER and OFF TIMER


• A sample setting for combining the 2 timers is shown below.
(Example)
Present time: 23:00 (The unit operating)
OFF TIMER at 0:00
Combined
ON TIMER at 14:00

NOTE
„ In the following cases, set the timer again.
• After a breaker has turned off.
• After a power failure.
• After replacing batteries in the remote controller.

21
01_EN_3P297290-1C.indd 21 12/8/2015 13:27:35
WEEKLY TIMER Operation

English
Up to 4 timer settings can be saved for each day of the week. It is convenient if the WEEKLY TIMER is set
according to the family’s life style.

„ Using in these cases of WEEKLY TIMER


Example: The same timer settings are made for the week from Monday through Friday while different timer settings are made
for the weekend.

[Monday] Make timer settings up to programs 1-4. Page 23

Program 1 Program 2 Program 3 Program 4


ON OFF ON OFF
77°F (25°C) 81°F (27°C)
6:00 8:30 17:30 22:00

ON OFF ON OFF

[Tuesday] Use the copy mode to make settings for Tuesday to Friday, because these settings are the same as those
to for Monday. Page 25
[Friday]
Program 1 Program 2 Program 3 Program 4
ON OFF ON OFF
77°F (25°C) 81°F (27°C)
6:00 8:30 17:30 22:00

[Saturday] No timer settings

[Sunday] Make timer settings up to programs 1-4. Page 23

Program 1 Program 2 Program 3 Program 4


ON OFF OFF ON
77°F (25°C) 81°F (27°C) 81°F (27°C)
8:00 10:00 19:00 21:00

ON OFF OFF ON

• Up to 4 reservations per day and 28 reservations per week can be set in the WEEKLY TIMER. The effective use of the copy
mode ensures ease of making reservations.
• The use of ON-ON-ON-ON settings, for example, makes it possible to schedule operating mode and set temperature changes.
Furthermore, by using OFF-OFF-OFF-OFF settings, only the turn off time of each day can be set. This will turn off the air
conditioner automatically if the user forgets to turn it off.

22
01_EN_3P297290-1C.indd 22 12/8/2015 13:27:35
WEEKLY TIMER Operation
„ To use WEEKLY TIMER operation
Setting mode
• Make sure the day of the week and time are set. If not, set the day of the week and time.
Page 10

Program 1 Program 2 Program 3 Program 4


ON OFF ON OFF

[Monday] 77°F (25°C) 81°F (27°C)


6:00 8:30 17:30 22:00

Setting Displays

Day and number settings ON/OFF settings Time settings Temperature settings

1. Press .
• The day of the week and the reservation number of the current day will be displayed.
• 1 to 4 settings can be made per day.

2. Press to select the desired day of the


week and reservation number.
• Pressing changes the reservation number and the day of the week.

3. Press .
• The day of the week and reservation number will be set.
•“ ” and “ ” blink.

4. Press to select the desired mode.


• Pressing changes “ ” or “ ” setting in sequence.

Pressing puts the sequence in reverse.


ON TIMER OFF TIMER blank

• In case the reservation has already been set, selecting “blank” deletes the
reservation.
• Go to STEP 9 if “blank” is selected.

5. Press .
• The ON/OFF TIMER mode will be set.
•“ ” and the time blink.

23
01_EN_3P297290-1C.indd 23 12/8/2015 13:27:36
English
6. Press to select the desired time.
• The time can be set between 0:00 and 23:50 in 10 minute intervals.
• To return to the ON/OFF TIMER mode setting, press .
• Go to STEP 9 when setting the OFF TIMER.

7. Press .
• The time will be set.
•“ ” and the temperature blink.

8. Press to select the desired temperature.


• The temperature can be set between 50°F (10°C) and 90°F (32°C).
Cooling: The unit operates at 64°F (18°C) even if it is set at 50°F (10°C) to 63°F (17°C).
Heating: The unit operates at 86°F (30°C) even if it is set at 87°F (31°C) to 90°F (32°C).
• To return to the time setting, press .
• The set temperature is only displayed when the mode setting is on.

9. Press .
• The temperature will be set and go to the next reservation setting.
• To continue further settings, repeat the procedure from STEP 4.

10. Press to complete the setting.


• Be sure to direct the remote controller toward the indoor unit and check for a receiving
tone and flashing the OPERATION lamp.
•“ ” is displayed on the LCD and WEEKLY TIMER operation is activated.
• The TIMER lamp lights yellow.

Display

• A reservation made once can be easily copied and the same settings used for another
day of the week. Refer to Copy mode . Page 25

NOTE
„ Notes on WEEKLY TIMER operation
• Do not forget to set the clock on the remote controller first. Page 10
• The day of the week, ON/OFF TIMER mode, time and set temperature (only for ON TIMER mode) can be set with WEEKLY TIMER.
Other settings for ON TIMER are based on the settings just before the operation.
• Both WEEKLY TIMER and ON/OFF TIMER operation cannot be used at the same time. The ON/OFF TIMER operation has priority if it is set
while WEEKLY TIMER is still active. The WEEKLY TIMER will go into standby state, and “ ” will be no longer displayed on the LCD.
When ON/OFF TIMER is up, the WEEKLY TIMER will automatically become active.
• Only the time and set temperature with the WEEKLY TIMER are sent with the . Set the WEEKLY TIMER only after setting the operation
mode, the airflow rate and the airflow direction ahead of time.
• Shutting the breaker off, power failure, and other similar events will render operation of the indoor unit’s internal clock inaccurate. Reset the
clock. Page 10
• The can be used only for the time and temperature settings. It cannot be used to go back to the reservation number.

24
01_EN_3P297290-1C.indd 24 12/8/2015 13:27:37
WEEKLY TIMER Operation
Copy mode
• A reservation made once can be copied to another day of the week. The whole reservation
of the selected day of the week will be copied.
Program 1 Program 2 Program 3 Program 4
ON OFF ON OFF

[Monday] 77°F (25°C) 81°F (27°C)


6:00 8:30 17:30 22:00
COPY
Program 1 Program 2 Program 3 Program 4
ON OFF ON OFF
[Tuesday]
to 77°F (25°C) 81°F (27°C)
[Friday] 6:00 8:30 17:30 22:00

Setting Displays

Confirmation display Copy display Paste display Normal display

1. Press .

2. Press to confirm the day of the week to be


copied.
3. Press .
• The whole reservation of the selected day of the week will be copied.

4. Press to select the destination day of the week.

5. Press .
• The reservation will be copied to the selected day of the week. The whole reservation
of the selected day of the week will be copied.
• To continue copying the settings to other days of the week, repeat STEP 4 and
STEP 5.

6. Press to complete the setting.


•“ ” is displayed on the LCD and WEEKLY TIMER operation is activated.

NOTE
„ Note on COPY MODE
• The entire reservation of the source day of the week is copied in the copy mode.
In the case of making a reservation change for any day of the week individually after copying the content of weekly reservations, press
and change the settings in the steps of Setting mode . Page 23

25
01_EN_3P297290-1C.indd 25 12/8/2015 13:27:38
English
„ Confirming a reservation
• The reservation can be confirmed.

Setting Displays

Normal display Confirmation display

1. Press .
• The day of the week and the reservation number of current day will be displayed.

2. Press to select the day of the week and


the reservation number to be confirmed.
• Pressing displays the reservation details.

• To change the confirmed reserved settings, select the reservation number and press
.
The mode is switched to setting mode. Go to Setting mode STEP 4. Page 23

3. Press to exit confirming mode.


•“ ” is displayed on the LCD and WEEKLY TIMER operation is activated.
• The TIMER lamp lights yellow.

Display

„ To deactivate WEEKLY TIMER operation

Press while “ ” is displayed on


the LCD.
• “ ” will be no longer displayed on the LCD.
• The TIMER lamp goes off.
• To reactivate the WEEKLY TIMER operation, press again.
• If a reservation deactivated with is activated once again, the last reservation
mode will be used.

26
01_EN_3P297290-1C.indd 26 12/8/2015 13:27:39
WEEKLY TIMER Operation
„ To delete reservations
The individual reservation

1. Press .
• The day of the week and the reservation number will be displayed.

2. Press to select the day of the week and


the reservation number to be deleted.
3. Press .
•“ ” and “ ” or “ ” blink.

4. Press and select “ blank ”.


• Pressing changes ON/OFF TIMER mode.

• The reservation will be no setting with selecting “blank”.

Pressing puts the sequence in reverse.


ON TIMER OFF TIMER blank

5. Press .
• The selected reservation will be deleted.

6. Press .
• If there are still other reservations, WEEKLY TIMER operation will be activated.

The reservations for each day of the week


• This function can be used for deleting reservations for each day of the week.
• It can be used while confirming or setting reservations.

1. Press .
• The day of the week and the reservation number will be displayed.

2. Press to select the day of the week to be


deleted.
3. Hold for 5 seconds.
• The reservation of the selected day of the week will be deleted.

4. Press .
• If there are still other reservations, WEEKLY TIMER operation will be activated.

All reservations

Hold for 5 seconds while normal display.


• Be sure to direct the remote controller toward the indoor unit and check for a receiving tone.
• This operation is not effective on the setting display of WEEKLY TIMER.
• All reservations will be deleted.

27
01_EN_3P297290-1C.indd 27 12/8/2015 13:27:39
Note for Multi System

English
Multi system has one outdoor unit connected to multiple indoor units.

„ Selecting the operation mode


With the priority room setting present but A room B room
inactive or not present.
When more than one indoor unit is operating, priority is given to the
first unit that was turned on.
In this case, set the units that are turned on later to the same operation
mode as the first unit. C room D room
Otherwise, they will enter the standby state, and the OPERATION
lamp will flash: this does not indicate malfunction.

NOTE Outdoor unit

„ Notes on operation mode for multi system


• COOL, DRY and FAN operation may be used at the same time.
• AUTO operation automatically selects COOL operation or HEAT operation based on the room temperature.
Therefore, AUTO operation is available when selecting the same operation mode as that of the room with the first unit to be turned on.

CAUTION
• Normally, the operation mode in the room where the unit is first run is given priority, but the following situations are exceptions, so please keep this
in mind.
If the operation mode of the first room is FAN operation, then using HEAT operation in any room after this will give priority to HEAT operation. In
this situation, the air conditioner running in FAN operation will go on standby, and the OPERATION lamp will flash.

With the priority room setting active.


Refer to “Priority room setting” on the next page.

„ NIGHT QUIET mode (Available only for COOL operation)


NIGHT QUIET mode requires initial programming during installation. Please consult your retailer or dealer for assistance.
NIGHT QUIET mode reduces the operation noise of the outdoor unit during the nighttime hours to prevent annoyance to
neighbors.
• The NIGHT QUIET mode is activated when the temperature drops 10.8°F (6°C) or more below the highest temperature recorded that day.
Therefore, when the temperature difference is less than 7.2°F (4°C), this function will not be activated.
• NIGHT QUIET mode reduces slightly the cooling efficiency of the unit.

„ OUTDOOR UNIT QUIET operation


Refer to “OUTDOOR UNIT QUIET operation”. Page 18

With the priority room setting present but inactive or not present.
When using the OUTDOOR UNIT QUIET operation feature with the Multi system, set all indoor units to OUTDOOR UNIT
QUIET operation using their remote controllers.
When clearing OUTDOOR UNIT QUIET operation, clear one of the operating indoor units using their remote controller.
However OUTDOOR UNIT QUIET operation display remains on the remote controller for other rooms.
We recommend you release all rooms using their remote controllers.

With the priority room setting active.


Refer to “Priority room setting” on the next page.

28
01_EN_3P297290-1C.indd 28 12/8/2015 13:27:40
Note for Multi System
„ COOL / HEAT mode lock
The COOL / HEAT mode lock requires initial programming during installation. Please consult your authorized dealer for
assistance. The COOL / HEAT mode lock sets the unit forcibly to either COOL or HEAT operation. This function is convenient
when you wish to set all indoor units connected to the multi system to the same operation mode.

„ Priority room setting


The priority room setting requires initial programming during installation. Please consult your authorized dealer for assistance.
The room designated as the priority room takes priority in the following situations.

Operation mode priority


• As the operation mode of the priority room takes precedence, the user can select a different operation mode from other
rooms.
[Example]
• Room A is the priority room in the examples.
When COOL operation is selected in room A while operating the following modes in room B, C and D :
Operation mode in room B, C and D Status of room B, C and D when the unit in room A is in COOL operation
COOL or DRY or FAN Current operation mode maintained
HEAT The unit enters standby mode. Operation resumes when the room A unit stops operating.
If the unit is set to COOL operation, it continues. If the unit is set to HEAT operation, it enters standby
AUTO
mode. Operation resumes when the room A unit stops operating.

Priority when POWERFUL operation is used


[Example]
• Room A is the priority room in the examples.
The indoor units in rooms A, B, C and D are all operating. If the unit in room A enters POWERFUL operation, operation
capacity will be concentrated in room A. In such a case, the cooling (heating) efficiency of the units in room B, C and D may
be slightly reduced.

Priority when using OUTDOOR UNIT QUIET operation


[Example]
• Room A is the priority room in the examples.
Just by setting the unit in room A to QUIET operation, the air conditioner starts OUTDOOR UNIT QUIET operation.
You don’t have to set all the operated indoor units to QUIET operation.

29
01_EN_3P297290-1C.indd 29 12/8/2015 13:27:40
Care and Cleaning

English
„ Quick reference
How to open / close the front panel
• Hold the front panel by the panel tabs on the both sides and open it.
• Press the front panel at both sides and the center to close it.
Panel tab
Cleaning parts

Air filter Front panel


• Vacuum dust or • Wipe it with a soft damp cloth.
wash the filter. If bothered by dirt
Once every Refer to Page 31
2 weeks
Refer to Page 32

Titanium apatite photocatalytic air-purifying filter Indoor unit,


• Vacuum dust or replace the filter.
Outdoor unit and
Remote controller
[Cleaning] [Replacement]
Once every 6 months Once every 3 years • Wipe them with a soft cloth.
Refer to Page 33 Refer to Page 33 If bothered by dirt

Notes on cleaning

„ For cleaning, do not use the materials as follows.


• Hot water above 104°F (40°C).
• Benzine, gasoline, thinner, other volatile oils.
• Polishing compound.
• Scrubbing brushes, other hard stuff.

CAUTION
• Before cleaning, be sure to stop the operation and turn the breaker off.
• Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury.

30
01_EN_3P297290-1C.indd 30 12/8/2015 13:27:40
Care and Cleaning
„ Front panel

1. Remove the front panel. 2. Clean the front panel.


• Open the front panel. • Wipe it with a soft damp cloth.
• Slide the front panel to either the left or right and • Only neutral detergent may be used.
pull it toward you. • In case of washing the panel with water, wipe it
This will disconnect the front panel shaft on one with a dry soft cloth, and let it dry in the shade after
side. washing.

2) Pull
3. Attach the front panel.
Front panel shaft • Align the front panel shaft on the left and right of
the front panel with the slots, then push them all
1) Slide the way in.

Front panel
2) Pull shaft

Slot
1) Slide

• Disconnect the front panel shaft on the other side


in the same manner.

• Close the front panel slowly. (Press the panel at


both sides and the central area.)

CAUTION
• When removing or attaching the front panel, stand on a solid, stable base and take care not to fall.
• When removing or attaching the front panel, support the panel securely with hand to prevent it from falling.
• After cleaning, make sure that the front panel is securely fixed.

31
01_EN_3P297290-1C.indd 31 12/8/2015 13:27:41
English
„ Air filter

1. Pull out the air filters. If the dust does not come off easily
• Open the front panel.
• Wash the air filters with neutral detergent thinned with
• Push the filter tab at the center of each air filter
lukewarm water, then let them dry in the shade.
slightly upward, then pull it down.
• Be sure to remove the titanium apatite photocatalytic
air-purifying filter. Refer to “Titanium apatite
photocatalytic air-purifying filter” on the next page.

1) Push

3. Set the filters as they were


and close the front panel.
• Press the front panel at both sides and the central
2) Pull down area.

2. Wash the air filters with


water or clean them with
vacuum cleaner.
• It is recommended to clean the air filters every
2 weeks.

CAUTION
• Do not touch the aluminum fins by bare hand at the time of dismounting or mounting the filter.

32
01_EN_3P297290-1C.indd 32 12/8/2015 13:27:42
Care and Cleaning
„ Titanium apatite photocatalytic air-purifying filter

1. Take off the titanium apatite [Replacement]


photocatalytic air-purifying Remove the tabs on the filter
filter. frame and replace with a new
• Open the front panel and pull out the air filters. filter.
• Hold the recessed parts of the frame and unhook
the 4 claws.

• Do not throw away the filter frame. Reuse the filter


Claw frame when replacing the titanium apatite
photocatalytic air-purifying filter.
• Dispose of the old filter as non-flammable waste.

3. Set the filters as they were


and close the front panel.
• Press the front panel at both sides and the central

2. Clean or replace the titanium area.

apatite photocatalytic air-


purifying filter.
[Maintenance]
2-1 Vacuum dust, and soak in lukewarm
water or water for about 10 to
15 minutes if dirt is heavy.
• Do not remove the filter from frame when washing
with water. NOTE
• Operation with dirty filters:
– cannot deodorize the air,
– cannot clean the air,
– results in poor heating or cooling,
– may cause odor.
• Dispose of old filters as non-flammable waste.
• To order a titanium apatite photocatalytic air-purifying
filter, contact the dealer where you bought the air
2-2 After washing, shake off remaining conditioner.
water and dry in the shade. Titanium apatite photocatalytic
Item
• Since the material is made out of polyester, do not air-purifying filter (without frame) 1 set
wring out the filter when removing water from it.
Part No. KAF970A46

33
01_EN_3P297290-1C.indd 33 12/8/2015 13:27:42
English
„ Check the units
„ Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.
„ Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
„ Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
• If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the service shop if this is the
case.

„ Before a long idle period

1. Operate the FAN only for several hours on a nice day to dry out
the inside.
• Press and select “ ” operation.
• Press and start the operation.

2. After operation stops, turn off the circuit breaker for the room air
conditioner.

3. Clean the air filters and set them again.


4. Take out batteries from the remote controller.
• When a multi outdoor unit is connected, make sure the HEAT operation is not being used in other rooms before you use
the FAN operation. Page 28

„ We recommend periodical maintenance


• In certain operating conditions, the inside of the air conditioner may get foul after several seasons of use, resulting in poor
performance. It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user.
• For specialist maintenance, contact the service shop where you purchased the air conditioner.
• The maintenance cost must be borne by the user.

34
01_EN_3P297290-1C.indd 34 12/8/2015 13:27:43
Troubleshooting
„ These incidents are not malfunctions.
• The following incidents do not indicate a malfunctioning air conditioner and have explanations. The air conditioner can continue to operate.

Indoor unit

Possible sounds.
„ Flowing water
• Generated because the refrigerant in the air conditioner is
flowing.
• This is a pumping sound of the water in the air conditioner The flaps do not start swinging immediately.
it is heard when the water is pumped out from the air
conditioner in cooling or drying operation.
The flaps move soon after startup.
• The refrigerant flows in the air conditioner even if the air
• The air conditioner is adjusting the position of the
conditioner is not working when the indoor units in other
flaps. The flaps will start moving soon.
rooms are in operation.
„ Blowing
• Generated when the flow of the refrigerant in the air The HEAT operation stops suddenly
conditioner is switched over.
„ Ticking and a flowing sound is heard.
• Generated when the size of the air conditioner slightly
• The outdoor unit is taking away the frost. The HEAT
expands or shrinks as a result of temperature changes.
operation starts after the frost on the outdoor unit is
„ Whistling sound
removed. You should wait for about 4 to 12 minutes.
• Generated when refrigerant flows during defrosting
operation.
„ Clicking sound during operation or idle time Operation does not start soon.
• Generated when the refrigerant control valves or the
electrical parts operate. „ When “ON/OFF” button was pressed soon
„ Clopping sound after operation was stopped.
• Heard from the inside of the air conditioner when the
„ When the mode was reselected.
exhaust fan is activated while the room doors are closed.
• This is to protect the air conditioner.
Open the window or turn off the exhaust fan.
You should wait for about 3 minutes.

Outdoor unit

Operating sound is loud.


• When frost forms on the heat exchanger of the outdoor unit, the operating
sound level increases slightly.

The outdoor unit emits water or steam.


„ In HEAT operation
• The frost on the outdoor unit melts into water or steam when the air
conditioner is in defrost operation.
„ In COOL or DRY operation
• Moisture in the air condenses into water on the cool surface of outdoor unit
piping and drips.

35
01_EN_3P297290-1C.indd 35 12/8/2015 13:27:43
English
• Troubleshooting measures are classified into the following two types on a remedial basis.
Take an appropriate measure according to the symptom.

Not malfunction
• The following conditions do not indicate a problem with the system.

Check
• Please check again before calling a repair person.

The air conditioner does not operate. Operation stopped suddenly.


(OPERATION lamp is off.) (OPERATION lamp flashes.)
• Is a breaker off or a fuse blown? • Are the air filters clean?
• Is there a power failure? Clean the air filters.
• Are batteries set in the remote controller? • Is there anything to block the air inlet or the outlet of the
• Is the timer setting correct? indoor and the outdoor units?
• Turn the bleaker off and take all obstacles away. Then
turn it on again and try operating the air conditioner with
the remote controller. If the lamp still flashes, call the
service shop where you purchased the air conditioner.
• Are operation modes all the same for indoor units
connected to outdoor units in the multi system?
Air does not come out. If not, set all indoor units to the same operation mode
and confirm that the lamps flash.
„ In HEAT operation When the operation mode is in “AUTO”, set all indoor
• The air conditioner is warming up. Wait for about 1 to 4
unit operation modes to “COOL” or “HEAT” for a moment
minutes.
and check again that the lamps are normal. If the lamps
• During defrosting operation, hot air does not flow out of
stop flashing after the above steps, there is no
the indoor unit.
malfunction. Page 28
„ When the air conditioner operates immediately
after the circuit breaker is turned on
• The air conditioner is preparing to operate. Wait for about
3 to 20 minutes.

Mist comes out of the indoor unit.


• This happens when the air in the room is cooled into
mist by the cold airflow during COOL operation.
Operation stopped suddenly. • This is because the air in the room is cooled by the heat
(OPERATION lamp is on.) exchanger and becomes mist during defrosting
operation.
• For system protection, the air conditioner may stop
operating on a sudden large voltage fluctuation. It
automatically resumes operation in about 3 minutes.

36
01_EN_3P297290-1C.indd 36 12/8/2015 13:27:43
Troubleshooting
Cooling (Heating) effect is poor. The ON/OFF TIMER does not
operate according to the settings.
• Are the air filters clean?
• Is there anything to block the air inlet or the outlet of the • Check if the ON/OFF TIMER and the WEEKLY TIMER
indoor and the outdoor units? are set to the same time.
• Is the temperature setting appropriate? Change or deactivate the settings in the WEEKLY
• Are the windows and doors closed? TIMER. Page 22
• Are the airflow rate and the airflow direction set
appropriately?

The indoor unit gives out odor.


Remote controller does not work • This happens when smells of the room, furniture, or
properly. cigarettes are absorbed into the unit and discharged with
the airflow.
„ No remote controller signals are displayed. (If this happens, have the indoor unit washed by a
„ Remote controller sensitivity is low. technician from the service shop where you purchased
„ Display is low in contrast or blacked out. the air conditioner.)
„ Display runs out of control.
• The batteries are dying and the remote controller is
malfunctioning. Replace all the batteries with new, size
AAA.LR03 (alkaline). For details, refer to “To set the
batteries” of this manual. Page 9
The outdoor fan rotates while the
air conditioner is not in operation.
„ After operation is stopped
• The outdoor fan continues rotating for another
HEAT operation cannot be selected, 60 seconds for system protection.
even though the unit is heat pump „ While the air conditioner is not in operation
model. • When the outdoor temperature is very high, the outdoor
fan starts rotating for system protection.
• Slide the DIP switch to the left as shown in the illustration
so that the HEAT operation can be selected with the
“MODE” button.

DIP switch

An abnormal functioning happens


during operation.
• The air conditioner may malfunction with lightning or
radio waves. Turn the breaker off, turn it on again and try
operating the air conditioner with the remote controller.

37
01_EN_3P297290-1C.indd 37 12/8/2015 13:27:44
English
„ Call the service shop immediately

WARNING
„ When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker off.
• Continued operation in an abnormal condition may result in malfunctioning, electric shocks or fire.
• Consult the service shop where you purchased the air conditioner.
„ Do not attempt to repair or modify the air conditioner by yourself.
• Incorrect work may result in electric shocks or fire.
• Consult the service shop where you purchased the air conditioner.

If one of the following symptoms occurs, call the service shop immediately.

• The power cord is abnormally hot or damaged.


• An abnormal sound is heard during operation.
• The safety breaker, a fuse, or the ground leakage breaker
cuts off the operation frequently. Turn the breaker off and call the service shop.
• A switch or a button often fails to work properly.
• There is a burning smell.
• Water leaks from the indoor unit.

„ After a power failure


• The air conditioner automatically resumes operation in about 3 minutes. Wait for it to restart.

„ Lightning
• If lightning may strike the neighboring area, stop operation and turn the breaker off for system protection.

„ Disposal requirements
• Dismantling the unit, and treatment of refrigerant, oil, and other parts, should be done in accordance with the relevant local and
national regulations.

38
01_EN_3P297290-1C.indd 38 12/8/2015 13:27:44
Troubleshooting
„ Fault diagnosis by remote controller
• The remote controller can receive a corresponding error code from the indoor unit.

1. When is held down for about


5 seconds, “ ” blinks in the temperature
display section.

2. Press repeatedly until a continuous


beep is produced.
• The code indication changes as displayed in the following table, and notifies with a
long beep.

CODE MEANING
00 NORMAL
UA INDOOR-OUTDOOR UNIT COMBINATION FAULT
SYSTEM U0 REFRIGERANT SHORTAGE
U2 DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE
U4 FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR UNIT)
A1 INDOOR PCB DEFECTIVENESS
A5 HIGH PRESSURE CONTROL OR FREEZE-UP PROTECTOR
INDOOR
A6 FAN MOTOR FAULT
UNIT
C4 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
C9 FAULTY SUCTION AIR TEMPERATURE SENSOR
EA COOLING-HEATING SWITCHING ERROR
E1 CIRCUIT BOARD FAULT
E5 OL STARTED
E6 FAULTY COMPRESSOR START UP
E7 DC FAN MOTOR FAULT
E8 OVERCURRENT INPUT
F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL
F6 HIGH PRESSURE CONTROL (IN COOLING)
OUTDOOR H0 SENSOR FAULT
UNIT H6 OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR
H8 DC CURRENT SENSOR FAULT
H9 FAULTY SUCTION AIR TEMPERATURE SENSOR
J3 FAULTY DISCHARGE PIPE TEMPERATURE SENSOR
J6 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
L3 ELECTRICAL PARTS HEAT FAULT
L4 HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK
L5 OUTPUT OVERCURRENT
P4 FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR

NOTE
• A short beep and two consecutive beeps indicate non-corresponding codes.
• To cancel the code display, hold for 5 seconds. The code display also cancel itself if the button is not pressed for 1 minute.

39
01_EN_3P297290-1C.indd 39 12/8/2015 13:27:44
English
„ MEMO

40
01_EN_3P297290-1C.indd 40 12/8/2015 13:27:44
Quick Reference

The two-dimensional bar code is


a manufacturing code.

3P297290-1C M11B116A (1511) HT

00_CV_3P297290-1C.indd 2 10/29/2015 13:30:25

You might also like