0% found this document useful (0 votes)
27 views17 pages

Harmony Timer Relays - RE7CV11BU

The document provides product specifications for an industrial timing relay. It includes details on the relay's time delay range, rated voltages and currents, temperature ratings, terminals, and wiring diagrams.

Uploaded by

guilhermealencar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views17 pages

Harmony Timer Relays - RE7CV11BU

The document provides product specifications for an industrial timing relay. It includes details on the relay's time delay range, rated voltages and currents, temperature ratings, terminals, and wiring diagrams.

Uploaded by

guilhermealencar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

Product data sheet

Specifications

asymmetrical flashing relay - 0.05..1


s - 24 V AC DC - 1OC
RE7CV11BU

Discontinued on: 01 June 2016

Discontinued

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range of product Zelio Time

Product or component type Industrial timing relay

Component name RE7

Time delay type L


Lt
Li

Time delay range 0.05 s...300 h

Complementary
Discrete output type Relay

Contacts material 90/10 silver nickel contacts

Width pitch dimension 22.5 mm

[Us] rated supply voltage 110...240 V AC 50/60 Hz


24 V AC/DC 50/60 Hz
42...48 V AC/DC 50/60 Hz

Voltage range 0.85...1.1 Us

Connections - terminals Screw terminals, 2 x 1.5 mm² flexible with cable end
Screw terminals, 2 x 2.5 mm² flexible without cable end

Tightening torque 0.6…1.1 N.m

Setting accuracy of time delay +/- 10 % of full scale

Repeat accuracy +/- 0.2 %

Temperature drift < 0.07 %/°C

Voltage drift < 0.2 %/V

Minimum pulse duration 20 ms

Reset time 50 ms

Maximum switching voltage 250 V AC/DC

Mechanical durability 20000000 cycles

[Ith] conventional free air 8A


thermal current

Maximum [Ie] rated operational 2 A DC-13 24 V at 70 °C conforming to IEC 60947-5-1/1991/VDE 0660


current 0.1 A DC-13 250 V at 70 °C conforming to IEC 60947-5-1/1991/VDE 0660
0.2 A DC-13 115 V at 70 °C conforming to IEC 60947-5-1/1991/VDE 0660
3 A AC-15 at 70 °C conforming to IEC 60947-5-1/1991/VDE 0660

Jan 16, 2023 1


Minimum switching capacity at 12 V 10 mA

Input voltage < 60 V X1Z2 terminal(s)


< 60 V X2Z2 terminal(s)

Maximum switching current 1 mA (X1Z2)


1 mA (X2Z2)

Input compatibility 3/4 wires sensors PNP/NPN without internal load <50 m X1Z2 terminal(s)
3/4 wires sensors PNP/NPN without internal load <50 m X2Z2 terminal(s)

Potentiometer characteristic Linear 47 kOhm (+/- 20 %), 0.2 W, cable length <25 m Z1Z2 terminal(s)

Marking CE

Overvoltage category III conforming to IEC 60664-1

[Ui] rated insulation voltage 250 V between contact circuit and control inputs IEC certified
250 V between contact circuit and power supply IEC certified
300 V between contact circuit and control inputs CSA certified
300 V between contact circuit and power supply CSA certified

Supply disconnection value > 0.1 Uc

Operating position Any position without derating

Surge withstand 2 kV conforming to IEC 61000-4-5 level 3

Power consumption in VA 0.7 VA at 24 V


1.6 VA at 48 V
1.8 VA at 110 V
8.5 VA at 240 V

Maximum power consumption in 0.5 W at 24 V


W 1.2 W at 48 V

Terminal description (B1-A2)CO


ALT
(15-16-18)OC_OFF

Height 78 mm

Width 22.5 mm

Depth 80 mm

Net weight 0.15 kg

Environment
Immunity to microbreaks 3 ms

Standards EN/IEC 61812-1

Product certifications UL
CSA
GL

Ambient air temperature for -40…85 °C


storage

Ambient air temperature for -20…60 °C


operation

Relative humidity 15…85 % 3K3 conforming to IEC 60721-3-3

Vibration resistance 0.35 mm (f= 10…55 Hz) conforming to IEC 60068-2-6

Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27

IP degree of protection IP20 (terminals)


IP50 (housing)

Pollution degree 3 conforming to IEC 60664-1

Dielectric strength 2.5 kV

Non-dissipating shock wave 4.8 kV

Resistance to electrostatic 6 kV in contact conforming to IEC 61000-4-2 level 3


discharge 8 kV in air conforming to IEC 61000-4-2 level 3

Resistance to electromagnetic 10 V/m conforming to IEC 61000-4-3 level 3


fields

2
Jan 16, 2023
Resistance to fast transients 2 kV conforming to IEC 61000-4-4 level 3

Disturbance radiated/ CISPR 22 - class A


conducted CISPR 11 group 1 - class A

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Contractual warranty
Warranty 18 months

Jan 16, 2023 3


Product data sheet RE7CV11BU
Dimensions Drawings

Width 22.5 mm

Rail Mounting

Screw Fixing

4
Jan 16, 2023
Product data sheet RE7CV11BU
Connections and Schema

Internal Wiring Diagram

Jan 16, 2023 5


Product data sheet RE7CV11BU
Connections and Schema

Recommended Application Wiring Diagram

Selection of Starting Phase

1 Supply
2 12…48 V
3 24 V
6 Start during the On-delay period: X2, Z2 linked.Start during the Off-delay period: X2, Z2 not linked.

6
Jan 16, 2023
Product data sheet RE7CV11BU
Connections and Schema

Control of Several Relays

Control of several relays with a single external control contact

Jan 16, 2023 7


Product data sheet RE7CV11BU
Connections and Schema

Connection of an External Control Contact Without Using Terminal Z2

Direct current supply only.


It is advisable to follow the recommended wiring schemes detailed above if the restrictions given are taken into account.

Direct current supply only.


It is advisable to follow the recommended wiring schemes detailed above if the restrictions given are taken into account.

8
Jan 16, 2023
Product data sheet RE7CV11BU
Connections and Schema

Connection 3-Wire NPN or PNP Sensor

Jan 16, 2023 9


Product data sheet RE7CV11BU
Connections and Schema

Connection 3-Wire NPN or PNP Sensor Without Using Terminal Z2

Connection NPN

It is advisable to follow the recommended wiring schemes detailed above if the restrictions given are taken into account.

Connection PNP

It is advisable to follow the recommended wiring schemes detailed above if the restrictions given are taken into account.

10
Jan 16, 2023
Product data sheet RE7CV11BU
Connections and Schema

Connection of Potentiometer

7 Off-delay adjustment (tr) (contact 15/16 closed).


8 On-delay adjustment (ta) (contact 15/18 closed).

Jan 16, 2023 11


Product data sheet RE7CV11BU
Connections and Schema

Connection Precautions

WARNING
UNEXPECTED EQUIPMENT OPERATION
No galvanic isolation between supply terminals and control inputs.
Failure to follow these instructions can result in death, serious injury, or equipment damage.

12
Jan 16, 2023
Product data sheet RE7CV11BU
Performance Curves

Performance Curves

A.C. Load Curve 1


Electrical durability of contacts on resistive loading millions of operating cycles

X Current broken in A
Y Millions of operating cycles

A.C. Load Curve 2


Reduction factor k for inductive loads (applies to values taken from durability curve 1).

X Power factor on breaking (cos ϕ)


Y Reduction factor k
Example: An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to 0.1 A and cos ϕ
= 0.3. For 0.1 A, curve 1 indicates a durability of approximately 1.5 million operating cycles. As the load is inductive, it is necessary to apply a
reduction coefficient k to this number of cycles as indicated by curve 2. For cos ϕ = 0.3: k = 0.6 The electrical durability therefore becomes:1.5
6
10 operating cycles x 0.6 = 900 000 operating cycles.

D. C. Load Limit Curve

X Current in A
Y Voltage in V
1 L/R = 20 ms
2 L/R with load protection diode
3 Resistive load

Jan 16, 2023 13


Product data sheet RE7CV11BU
Technical Description

Function L : Asymmetrical Flasher Relay (Starting Pulse Off)

Description
Repetitive cycle comprises of two, independently adjustable timing periods Ta and Tr. Each timing period corresponds to a different state of the
output R.

Function: 1 Output

14
Jan 16, 2023
Product data sheet RE7CV11BU
Technical Description

Function Li : Asymmetrical Flasher Relay (Starting Pulse On)

Description
Repetitive cycle comprises of two, independently adjustable timing periods Ta and Tr. Each timing period corresponds to a different state of the
output R.

Function: 1 Output

Jan 16, 2023 15


Product data sheet RE7CV11BU
Technical Description

Function Lt: Asymmetrical Flashing with Partial Stop of Timing

Description
Repetitive cycle comprises of two, independently adjustable timing periods Ta and Tr. Each timing period corresponds to a different state of the
output R.
Gate control contact G can be operated to partially stop timing periods Ta and Tr.

Function: 1 Output

Tr = t1 + t2 + ...
Ta = t’1 + t’2 +...

16
Jan 16, 2023
Product data sheet RE7CV11BU
Technical Description

Legend

Relay de-energised

Relay energised

Output open

Output closed

C Control contact

G Gate

R Relay or solid state output

R1/R2 2 timed outputs

R2 inst. The second output is instantaneous if the right position is selected

T Timing period

Ta - Adjustable On-delay

Tr - Adjustable Off-delay

U Supply

Recommended replacement(s)
RE7CV11BU is replaced by the following product range:

Harmony Timer Relays


Near Field Communication and conventional Timer Relays (formerly known as Zelio
Timer Relays)
Products: 83

Or RE7CV11BU is replaced by:

Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, asymmetrical flashing,


1x 24...240V AC DC
RE22R1MLMR

Jan 16, 2023 17