0% found this document useful (0 votes)
63 views2 pages

Humidity Temperature Controller

The document provides an operating manual for a temperature and humidity controller. It details the technical specifications, connection diagram, user configuration menu, and offset settings. The controller measures temperature using a PT-100 sensor and humidity using an RH-100SL sensor, and has two relay outputs for temperature and humidity control.

Uploaded by

ralyrepo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
63 views2 pages

Humidity Temperature Controller

The document provides an operating manual for a temperature and humidity controller. It details the technical specifications, connection diagram, user configuration menu, and offset settings. The controller measures temperature using a PT-100 sensor and humidity using an RH-100SL sensor, and has two relay outputs for temperature and humidity control.

Uploaded by

ralyrepo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

OPERATINGMANUAL

TEMPERATURE&HUMIDITYCONTROLLER
MHT-1202

TechnicalSpecification
1.MicroControllerBased,DoubleDisplay
2.Upperdisplay,7seg,red0.56”LEDforprocessvaluesensor1.
Lowerdisplay,7seg,green0.56”LEDforprocessvaluesensor2.
3.Dimension:Size:96(H)X96(W)X50(D)mm.
PanelCutout:92X92mm.
4.Input:PT-100/3W&Humiditysensor(RH-100SL)
5.Range:PT-100(0.0To400.0°C)
Humidity(0.0TO100.0%RH)
6.Supply:100To250VAC,50/60Hz,Approx4VA
7.Output:2Relay1C/O(On-Off)
8.ProtectionLevel:IP-65(Frontside)AsperIS/IEC60529:2001

NOTE:
1.MakeallconnectionproperlyaccordingtoʻCONNECTIONDIAGRAMʼgivenbelow.
ThenturnONinstrument.Setallparametersaccordingtoyourrequirement.
ThenpressENTERkeytostorenewvalueinmemory.
2.Display-1(upper)indicatestemperaturevalueforPt-100andDisplay-2(lower)
indicatestemperaturevalueforHumidity.
 Accurate Sensing of humidity is subject to proper mounting of humidity sensor
 as per application area. Please consult our support engineers if needed.

ConnectionDiagram
20 19 18 17 16 15 14 13 12 11
Y R B
I/P +5V DC GND
www.multispanindia.com
(RH-100SL) PT-100/3W

Range: 0.0 To 400.0°C


Made in India 0.0 To 100.0% RH
100 ~ Input: PT-100/3W
Humidity Sensor (RH-100SL)
250V AC
50/60 Hz Output: 2R1C/O (ON-OFF)
4VA
RELAY-1 RELAY-2
NO C NC NO C NC
L N
1 2 3 4 5 6 7 8 9 10

MHT-1202 Page-1 www.multispanindia.com


USERCONFIGURATION
Menu-1 PowerON
Presskey
SET

Set1 s E T 1 ForPT-100
0 5 0. 0 (0To400.0)
Presskey
SET

Hysteresis1 H Y S 1 ForPT-100
0 0 0. 5 (0.1To99.0)
Presskey
SET

Time1 T I M 1 ForPT-100 (IfRMod1=COOL)


0 0 0. 5 (0.0To99.9Min)
Presskey
SET

Set2 s E T 2 ForHumidity
1 0 0. 0 (0To85.0)
Presskey
SET

Hysteresis2 H Y S 2 ForHumidity
0 0 0. 5 (0.1To99.0)
Presskey
SET

Time2 T I M 2 ForHumidity (IfRMod2=H-AL)


0 0 0. 5 (0.0To99.9Min)
Presskey
SET

PassWord P A S S ForPassword
0 1 2 3 (0123)
Presskey
SET

SetLowLimit S L L ForPT-100
0 0 0. 0 (0000)
Presskey
SET

SetHighLimit S H L ForPT-100
4 0 0. 0 (0To400.0)
Presskey
SET

Mode1M O D 1 ForPT-100
H E A T Heat/Cool
Presskey
SET

M O D 2 ForHumidity
L - A L (L-AL/H-AL)
Presskey
SET

Presskeytosave&exit
ENT

Menu-2
Press+key

Offset1 O F S 1 ForPT-100
Presskey

0 0 0 0 Range:±20.0°C
Presskey
SET

SET

Offset2 O F S 2 ForHumidity
0 0 0 0 Range:±20.0%RH

Presskeytosave&exit
ENT

Productimprovementandupgradeisaconstantprocedure.Soformoreupdatedoperatinginformationandsupport,
pleasecontactourhelpline:+91-9978991474/76/82orEmailat[email protected]Ver:1902
MHT-1202 Page-2 www.multispanindia.com