Data Domain Solution - System Password Not Working
Data Domain Solution - System Password Not Working
PURPOSE
This article describes how to resolve the issue where the Data Domain system password is not working, or has been forgotten.
Symptoms:
APPLIES TO
CAUSE
There is a lockout that occurs after three failed attempts to login. The lockout period is two minutes but will reset after each failed
attempt after the initial lockout. Older Data Domain systems used “abc123” as the default password. On newer systems the default
password is the system serial number. Because the default password changed, it is common for the incorrect password to be
entered as installers are used to the older default password. Another common cause of lockout is that passwords are case sensitive
and can be entered incorrectly.
SOLUTION
NOTE: If the login issues are intermittent, please check if there are scripts running that are attempting to login to the Data Domain
System as well.
1. Ensure that the password is correct. If the lockout occurs during a new install, verify the default password in the Install/Setup
Guide.
2. Wait at least two minutes, then enter the correct password. Passwords are case sensitive.
1. Try using the factory defaultsysadminpassword as it might not have been changed. On newer systems the default
password is the system serial number in upper-case. Please note that 0F12345678 is not the same as 0f12345678;
Passwords are case-sensitive.
2. If the default password does not work, search the daily autosupport under the "REGISTRY" section for other users. Any user
with admin rights can login and create another user or reset the forgotten password. In the example below, three users have
admin rights.
3. If there are no other users with admin rights and none of the other solutions work, contact your service provider to have the
password reset.