0% found this document useful (0 votes)
48 views

Project Perstima Projection 09172022

The document provides details of an integrated membrane design software project including permeate and concentrate flow rates, recovery percentages, element specifications, feed water characteristics, and saturation and scaling indices. Stages include initial permeate and concentrate flows, flux rates, and pressure changes. Ion concentrations are listed for raw water, feed water, permeate, and concentrate streams.

Uploaded by

Janzzen Cruda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views

Project Perstima Projection 09172022

The document provides details of an integrated membrane design software project including permeate and concentrate flow rates, recovery percentages, element specifications, feed water characteristics, and saturation and scaling indices. Stages include initial permeate and concentrate flows, flux rates, and pressure changes. Ion concentrations are listed for raw water, feed water, permeate, and concentrate streams.

Uploaded by

Janzzen Cruda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Integrated Membranes Solutions Design Software

Created on: 09/17/2022 11:32:44

Permeate Throttling (Variable), Concentrate Recirculation


Project name Project PerstimalCoreco Page : 1/3
Calculated by JC Permeate flow/train 1500.0 m3/d
HP Pump flow 91.66 m3/h Raw water flow/train 2000.0 m3/d
Feed pressure 6.9 bar Permeate recovery 68.18 %
Feed temperature 25.0 °C(77.0°F) Total system recovery 75.00 %
Concentrate recirculation 200.0 m3/d Element age 0.0 years
Feed water pH 8.50 Flux decline %, first year 12.0
Chem dose, mg/l, - H2SO4 Fouling factor 1.00
Specific energy 0.35 kwh/m3 SP increase, per year 10.0 %
Pass NDP 1.9 bar Inter-stage pipe loss 0.207 bar
Average flux rate 12.7 lmh
Feed type Waste MF/UF

Pass - Perm. Flow / Vessel Flux DP Flux Beta Stagewise Pressure Perm. Element Element PV# x
Stage Flow Feed Conc Max Perm. Boost Conc TDS Type Quantity Elem #
m3/h m3/h m3/h lmh bar lmh bar bar bar mg/l
1-1 40.3 7.6 4.3 15.1 0.6 24.8 1.12 2.5 0 6.3 515.8 ESNA1-LF-LD 72 12 x 6M
1-2 22.2 5.1 2.9 10 0.3 17.3 1.13 1 0 5.8 1269.7 ESNA1-LF-LD 60 10 x 6M
Ion (mg/l) Raw Water Feed Water Permeate Water Concentrate 1 Concentrate 2
Hardness, as CaCO3 30.00 37.68 1.606 66.4 114.8
Ca 9.60 12.06 0.514 21.3 36.7
Mg 1.46 1.84 0.078 3.2 5.6
Na 1087.33 1304.12 270.086 2189.3 3509.9
K 0.00 0.00 0.000 0.0 0.0
NH4 6.82 7.11 2.426 10.4 12.4
Ba 0.000 0.000 0.000 0.0 0.0
Sr 0.000 0.000 0.000 0.0 0.0
H 0.00 0.00 0.000 0.0 0.0
CO3 0.00 0.01 0.001 0.0 0.0
HCO3 0.10 0.11 0.047 0.2 0.2
SO4 2006.00 2464.35 346.363 4227.1 7003.0
Cl 214.30 230.53 162.176 319.1 380.1
F 0.64 0.62 0.744 0.6 0.4
NO3 1.35 1.44 1.078 1.9 2.2
PO4 11.28 13.86 1.948 23.8 39.4
OH 0.05 0.06 0.028 0.1 0.1
SiO2 0.00 0.00 0.000 0.0 0.0
B 0.00 0.00 0.000 0.0 0.0
CO2 0.00 0.00 0.00 0.00 0.00
NH3 1.17 1.38 1.38 1.38 1.38
TDS 3338.89 4036.03 785.46 6796.91 10989.99
pH 8.50 8.55 8.22 8.72 8.84

Saturations Raw Water Feed Water Concentrate Limits


CaSO4 / ksp * 100, % 2 3 11 400
SrSO4 / ksp * 100, % 0 0 0 1200
BaSO4 / ksp * 100, % 0 0 0 10000
SiO2 saturation, % 0 0 0 140
CaF2 / ksp * 100, % 0 0 0 50000
Ca3(PO4)2 saturation index 0.7 0.9 1.7 2.4
CCPP, mg/l 0.17 0.20 0.45 850
Langelier saturation index -3.25 -3.04 -1.99 2.8
Ionic strength 0.07 0.08 0.23
Osmotic pressure, bar 1.6 1.9 5.0

Product performance calculations are based on nominal element performance when operated on a feed water of acceptable quality. The results shown on the printouts produced by this program are
estimates of product performance. No guarantee of product or system performance is expressed or implied unless provided in a separate warranty statement signed by an authorized Hydranautics
representative. Calculations for chemical consumption are provided for convenience and are based on various assumptions concerning water quality and composition. As the actual amount of chemical
needed for pH adjustment is feedwater dependent and not membrane dependent, Hydranautics does not warrant chemical consumption. If a product or system warranty is required, please contact your
Hydranautics representative. Non-standard or extended warranties may result in different pricing than previously quoted. Version : 2.231.90 %

Email : [email protected]
Integrated Membranes Solutions Design Software

Created on: 09/17/2022 11:32:44

Permeate Throttling (Variable), Concentrate Recirculation


Project name Project PerstimalCoreco Page : 2/3
Calculated by JC Permeate flow/train 1500.0 m3/d
HP Pump flow 91.66 m3/h Raw water flow/train 2000.0 m3/d
Feed pressure 6.9 bar Permeate recovery 68.18 %
Feed temperature 25.0 °C(77.0°F) Total system recovery 75.00 %
Concentrate recirculation 200.0 m3/d Element age 0.0 years
Feed water pH 8.50 Flux decline %, first year 12.0
Chem dose, mg/l, - H2SO4 Fouling factor 1.00
Specific energy 0.35 kwh/m3 SP increase, per year 10.0 %
Pass NDP 1.9 bar Inter-stage pipe loss 0.207 bar
Average flux rate 12.7 lmh
Feed type Waste MF/UF
Pass - Perm. Flow / Vessel Flux DP Flux Beta Stagewise Pressure Perm. Element Element PV# x
Stage Flow Feed Conc Max Perm. Boost Conc TDS Type Quantity Elem #
m3/h m3/h m3/h lmh bar lmh bar bar bar mg/l
1-1 40.3 7.6 4.3 15.1 0.6 24.8 1.12 2.5 0 6.3 515.8 ESNA1-LF-LD 72 12 x 6M
1-2 22.2 5.1 2.9 10 0.3 17.3 1.13 1 0 5.8 1269.7 ESNA1-LF-LD 60 10 x 6M
Permeat Permeate
Pass - Element Feed Pressure Conc NDP e Water Water Beta Permeate (Stagewise cumulative)
Stage no. Pressure Drop Osmo. Flow Flux TDS Ca Mg Na Cl
bar bar bar bar m3/h lmh
1-1 1 6.9 0.14 2.1 3 0.9 24.8 1.12 248.8 0.152 0.023 83.922 59.514
1-1 2 6.7 0.11 2.3 2.1 0.6 16.6 1.09 314.5 0.192 0.029 106.081 74.949
1-1 3 6.6 0.1 2.5 1.9 0.6 14.9 1.09 363.4 0.223 0.034 122.846 85.855
1-1 4 6.5 0.09 2.7 1.6 0.5 13.1 1.09 411.2 0.254 0.039 139.356 96.101
1-1 5 6.4 0.07 2.9 1.4 0.4 11.2 1.08 461.5 0.287 0.044 156.88 106.585
1-1 6 6.4 0.07 3.1 1.2 0.4 9.5 1.08 515.8 0.323 0.049 175.892 117.572

1-2 1 6.1 0.08 3.6 2.2 0.6 17.3 1.13 578.1 0.384 0.059 202.008 117.794
1-2 2 6 0.06 3.9 1.7 0.5 13.8 1.11 683.9 0.457 0.07 239.372 137.495
1-2 3 5.9 0.05 4.3 1.3 0.4 10.5 1.1 807.2 0.543 0.083 283.251 160.017
1-2 4 5.9 0.04 4.6 1 0.3 7.8 1.08 948.3 0.643 0.098 333.728 185.08
1-2 5 5.8 0.04 4.8 0.7 0.2 5.8 1.07 1104 0.755 0.115 389.741 211.747
1-2 6 5.8 0.04 5 0.6 0.2 4.4 1.05 1269.7 0.877 0.134 449.742 238.875

Product performance calculations are based on nominal element performance when operated on a feed water of acceptable quality. The results shown on the printouts produced by this program are
estimates of product performance. No guarantee of product or system performance is expressed or implied unless provided in a separate warranty statement signed by an authorized Hydranautics
representative. Calculations for chemical consumption are provided for convenience and are based on various assumptions concerning water quality and composition. As the actual amount of chemical
needed for pH adjustment is feedwater dependent and not membrane dependent, Hydranautics does not warrant chemical consumption. If a product or system warranty is required, please contact your
Hydranautics representative. Non-standard or extended warranties may result in different pricing than previously quoted. Version : 2.231.90 %

Email : [email protected]
Integrated Membranes Solutions Design Software

Created on: 09/17/2022 11:32:44

Permeate Throttling (Variable), Concentrate Recirculation


Project name Project PerstimalCoreco Page : 3/3
Temperature : 25.0 °C Element age, P1 : 0.0 years

Stream No. Flow (m3/h) Pressure (bar) TDS (mg/l) pH Econd (µs/cm)
1 83.3 0 3339 8.50 5342
2 91.7 0 4036 8.55 6328
3 91.7 6.86 4036 8.55 6328
4 51.4 6.29 6797 8.72 10165
5 29.2 5.77 10990 8.84 15773
6 8.33 0 10990 8.84 15773
7 20.8 0 10990 8.84 15773
8 40.3 2.50 516 8.05 1076
9 22.2 1.00 1270 8.41 2332
10 62.5 1.00 785 8.22 1535

Product performance calculations are based on nominal element performance when operated on a feed water of acceptable quality. The results shown on the printouts produced by this program are
estimates of product performance. No guarantee of product or system performance is expressed or implied unless provided in a separate warranty statement signed by an authorized Hydranautics
representative. Calculations for chemical consumption are provided for convenience and are based on various assumptions concerning water quality and composition. As the actual amount of chemical
needed for pH adjustment is feedwater dependent and not membrane dependent, Hydranautics does not warrant chemical consumption. If a product or system warranty is required, please contact your
Hydranautics representative. Non-standard or extended warranties may result in different pricing than previously quoted. Version : 2.231.90 %

Email : [email protected]

You might also like