Fill Rite 5200 Series Fr152 Hand Pump For Lav Cart Yxl
Fill Rite 5200 Series Fr152 Hand Pump For Lav Cart Yxl
To ensure safe and efficient operation, it is essential to read and follow each of these 4. Screw discharge spout assembly into top of pump.
warnings and precautions.
1. Improper use or installation of this product can cause serious bodily injury PUMPS WITH METER, HOSE AND NOZZLE
or death. 4. Screw street elbow into top of pump, nipple into street elbow, meter onto nipple.
2. Do NOT smoke near pump or use pump near an open flame when pumping NOTE: Position the meter to the right of the handle facing operator for ease of
flammable fluids. Fire could result. operator viewing. Screw one end of hose into meter outlet and the nozzle to the
other end of hose.
3. A Fill-Rite filter should be used on pump outlet to ensure that no foreign material
is transferred to fuel tank.
4. Use gasoline and oil resistant thread sealant or sealant tape on all threaded joints Pump Flow Reversal Instructions
to protect against leakage.
5. Storage tank or barrel should be anchored to prevent tipping in both the full and Rotating the piston 180° inside the pump will reverse the flow of the pump.
empty conditions. NOTE: Removing the piston is not required to complete this process.
6. To minimize static electricity build-up, keep nozzle in contact with container 1. Remove the linkage pin (item 14) that retains the links (item 13) on the piston
being filled. (item 3).
2. Using a wrench, rotate the piston 180°. Take care to avoid scratching the
piston shaft.
Warning
3. Reattach the links (item 13) using the removed linkage pin (item 14).
This product should not be used for fluid transfer into aircraft. This product is not suited 4. Remove the Anti-Siphon Valve (item 25) and replace with 3/4" NPT pipe plug.
for use with fluids for human comsumption or fluids containing water.
Fluid Compatibility
Operating Instructions
If in doubt about compatibility of a specific fluid, contact supplier of fluid to check
for any adverse reactions to the wetted materials. 1. Reset meter to 0 (if applicable).
Fluid Compatibility 2. Insert nozzle into tank (if applicable).
3. Operate handle to begin fluid flow.
Compatible Fluids Gasoline, Diesel, Heptane, Kerosene,
(Okay to pump) Stoddard Solvents, Light Oils, Mineral Spirits 4. When finished pumping, allow hose to drain and return nozzle to nozzle boot.
fillrite.com 2
| FR150 SERIES PISTON HAND PUMP INSTALLATION AND OPERATION MANUAL
Accessories
5200G9447 Rev.3
BOMBA MANUAL GIRATORIA DE SERIES FR150
Modelos FR150, FR151, FR152
Manual de instalación y operación
| BOMBA MANUAL GIRATORIA DE SERIES FR150 MANUAL DE INSTALACIÓN Y OPERACIÓN
Este producto no deberá ser usado para transferir fluidos a un avión. Este producto no es
apropiado para usarse con fluidos de consumo humano o con fluidos que contengan agua. Instrucciones de Operación
Compatibilidad de fluidos 1. Recoloque el medidor a 0 (si aplica).
Si tiene dudas sobre compatibilidad de algún fluido específico, póngase en contacto con
2. Inserte la boquilla dentro del tanque (si aplica).
el abastecedor del fluido para verificar si hay reacciones adversas con los materiales
mojados en la lista de piezas. 3. Opere la manija para iniciar el flujo del fluido.
4. Cuando termine de bombear, permita que la manguera drene y retorne la boquilla
Compatibilidad con líquidos al portaboquilla.
fillrite.com 5
| BOMBA MANUAL GIRATORIA DE SERIES FR150 MANUAL DE INSTALACIÓN Y OPERACIÓN
Arti-
N.º de pieza Descripción Cantidad
culo
1 5200F1332 Cuerpo, Pistón Bomba de Mano, Mecanizad 1
2 5200F1230 Pistón Mecanizado 1
3 5200F1260 Anillo de Pistón 2
4 100F0801 La Junta, Nitrilo 1
5 5200F1420 De Camisas, Pistones Bomba de Mano 1
6 5200F1300 Cubierta Del Pistón, Bomba de Mano 1
7 304F7904 1/4-20 HWHTFS 8
8 5200F1869 Vacio 1
9 5200F1310 Anillo de Guarnicíon Pistón Bomba de Mano 1
10 5200F1331 Tuerca Del Cojinete 1
11 5200G9351 Pantalla de Entrada 1
12 5200F1340 Enlace de Horquilla 2
13 5200F1460 Brazo de Bloqueo 1
14 5200F1350 Pasador de Horquilla 3
15 702F3259 Engance el Sujectador, #13 3
16 5200F1410 Remache, 1/4 x 5/8 1
17 5200G8869 Junta Tórica, Nitrilo-045 2
18 5200F1440 Arandela de Resorte 1
19 5200F1790 La Boquilla, Mecanizado 1
20 5200F1839 Conjunto Del Tubo de Aspiracíon 1
Conjunto de Manguera, Listado
21 SA001030-001 1
UL 5/8" x 8', TTS
22 100F0652 Etiqueta, Logo 1
Conjunto de Válvula de Pistón Bomba
23 5200F1262 4
de Mano
24 5200F1376 Plantilla Asamblea 1
25 5200F1619 Conjunto de tubo de descarga 1
Accesorios
5200G9447 Rev.3
POMPE MANUELLE ROTATIVE DE LA SÉRIE FR150
Modèles FR150, FR151, FR152
Manual d'installation et d'utilisation
| POMPE MANUELLE ROTATIVE DE LA SÉRIE FR150 MANUEL D'INSTALLATION ET D'UTILISATION
Avertissement
Mode d'Emploi
Ce produit ne doit pas être utilisé pour transférer du fluide dans un avion. Ce produit ne
convient pas aux fluides destinés à la consommation humaine ni aux fluides contenant 1. Réinitialisez le débitmètre sur 0 (le cas échéant).
de l’eau. 2. Insérez la buse dans le réservoir (le cas échéant).
Compatibilité de fluide 3. Actionnez la poignée pour commencer à débiter le fluide.
En cas de doute sur la compatibilité d’un fluide spécifique, contactez le fournisseur du 4. Après avoir terminé de pomper, laissez le flexible se vidanger, et remettez la buse
fluide pour connaître les risques de détérioration des matériaux humides indiqués dans la dans son logement.
nomenclature.
fillrite.com 8
| POMPE MANUELLE ROTATIVE DE LA SÉRIE FR150 MANUEL D'INSTALLATION ET D'UTILISATION
Accessoires
Référence Description
5200KTF1828 Nécessaire de réparation (avec articles 3, 4, 8, 9, 10, 11, 17, 23)
807CMK Nécessaire de débitmétre, galons
807 CLMK Nécessaire de débitmétre, litres
F1810PMO Filtre de Particules
F1810HMO Filgtre de Hydrosorb (arroser le filtre)
REMARQUE: Les fléches sur le piston doit pointer
1200KTG9075 Téte de filtre vers l'entree (en bas) lorsqu'il est installé. La pompe
ne fonctionne pas correctement s'il n'est pas installé
correctement.
5200G9447 Rev.3
SERIES FR150 KREISELPUMPE
Modelle FR150, FR151, FR152
Einbau-und betriebsanleitung
| SERIES FR150 KREISELPUMPE EINBAU-UND BETRIEBSANLEITUNG
Flüssigkeitsverträglichkeit
Behebung Von Störungen
Verträgliche Flüssigkeiten Benzin, Diesel, Heptan, Kerosin, Stoddard PUMPE SAUGHT NICHT AN: Auf Lecks in der Ansaugleitung überprüfen. Ventile und
(zum Pumpen geeignet) Lösungsmittel, Leichtöle, Mineralbeizen Kolben auf Kerben, Unebenheiten oder Abnutzung überprüfen. Ansaugleitung dichtung leckt.
Wasser, Schwefelsäure, Naptha, Methanol, NIEDRIGES FÖRDERVOLUMEN: Sieb entfernen und reinigen.Ansaugleitung auf
Unverträgliche Flüssigkeiten Lecks überprüfen.
Methylethylketon (MEK), Aceton, Ammoniak,
(NICHT pumpen)
Benzol, Bleiche, Chlor FLÜSSIGKEITASAUSTRITT: Spannmutter nachziehen. Dichtung austaschen.
Vakuumschalter austauschen. Abdeckungen und Schraubverbindunge nachziehen.
Danke! Sicherheit
Vielen Dank für den Kauf der FR150 Serie Piston Hand-Pumpe! Ihr Fill-Rite® Das
Produkt verfügt über mehr als 80 Jahre Erfahrung in der Pumpenherstellung, Mit dem
Wert, der mit überlegener Leistung, benutzerfreundlichem Design, herausragender
Haltbarkeit und solider, einfacher Technik einhergeht.
fillrite.com 11
| SERIES FR150 KREISELPUMPE EINBAU-UND BETRIEBSANLEITUNG
Zubehör
Teilenummer Beschreibung
5200KTF1828 Reparatursatz (Einschließlich lfd. Nr. 3, 4, 8, 9, 10, 11, 17, 23)
807CMK Durchflussmesser, Gallonen
807CLMK Durchflussmesser, Liter
F1810PMO Partikelfilter
HINWEIS: Die Pfeile auf dem Kolben muss zum
F1810HMO Hydrosorb (Wasser) Filter
Eingang (unten) wenn sie installiert ist. Pump wird nicht
1200KTG9075 Filterkopf rightig funktioneren, wenn nicht ordnungsgemäß insgtalliert
5200G9447 Rev.3