Glass Performance Data
GLAZING ORIENTATION
Dated : 02/01/2024
OUT 1 2 3 4 IN
Glazing Thickness Description Coating Position
o I
u A n
Emicool Vision cool Bronze on t i n
Outer Pane 6mm #2 r
Vitralite Clear e e
r S r
Air Space 6mm p
L a L
c
Inner Pane 6mm Vitralite Clear i
e
i
t t
e e
Outer Lite 6mm Emicool Vision cool Bronze on Vitralite Clear #2
Air Space 6mm
Inner Lite 6mm Vitralite Clear
Transmittance 17%
Visible Light Exterior Reflectance 11%
Interior Reflectance 12%
Transmittance 13%
Total Solar Energy
Exterior Reflectance 15%
UV Transmittance 13%
2
Summer (W/m -K) 2.9
NFRC U-Value
Winter (W/m2-K) 2.77
European U-Value (Ug-Value) (W/m2-K) 2.95
Solar Heat Gain Coefficient 0.25
Shading Coefficient 0.29
Relative Heat Gain (W/m2-K) 206
.
Glass Performance Analysis
NFRC calculations are done by using LAWRENCE BERKELEY NATIONAL LABORATORY Window database software v7.8 in NFRC 100-2010
Summer conditions.
Tolerances
The above data represent NOMINAL VALUES based on center-of-glass measurements and take no account of IG Spacers or framing. Slight Variations
might occur due to manufacturing as well as the type of instrumentation used to measure the spectrophotometric and thermal insulation values.
This is a computer-generated Document and hence no signature required.